Loading...
HomeMy WebLinkAboutWQ0041736_Sewer Extension_20200610RF_G vtlu DE iDWR State of North Carolina Department of Environmental Quality DWR JUN 10 2020 Division of Water Resources IV IV 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources MCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION 'IYF This application is for sewer extensions involving gravity sewers, pump stations and force mains, or any combination that has been certified by a professional engineer and the applicant that the project meets the requirements of I iA NCAC 02T and the Division's Minimum Design Criteria and that plans, specifications and supporting documents have been prepared in accordance with, 15A NCAC 02T, 15A NCAC 02T .0300, Division policies and good en2incerin2 practices. While no upfront engineering design documents are required for submittal, in accordance with 15A NCAC 02T .0305(b), design documents must be prepared prior to submittal of a fast track permit application to the Division. This would include plans, design calculations, and project specifications referenced in I5A NCAC 02T .0305 and the applicable minimum design criteria. These documents shall be available upon request by the Division. Projects that are deemed pennitted (do not require a permit from the Division) are explained in 15A NCAC 02T.0303. Projects not eligible for review via the fast track process (must be submitted for full technical review): ii Projects that require an environmental assessment in accordance with 15A NCAC IC .0100, Projects that do not meet any part of the minimum design criteria (MDC) document; Projects that involve a variance from the requirements of 15A NCAC 2T; Pressure sewer systems utilizing septic tank -effluent pumps (STEPS) or simplex grinder pumps; STEP or simplex grinder pumps connecting to pressurized systems (e.g. force mains); i- Vacuum sewer systems. General — When submitting an application, please use the following instructions as a checklist in order to ensure all required items are submitted. Adherence to these instructions and checking the provided boxes will help produce a quicker review time and reduce the amount of requested additional information. Failure to submit all required items will necessitate additional processing and review time, and may result in return of the application. Unless otherwise noted, the Applicant shall submit one original and one copy of the application and supporting documentation. A. One Original and One Copy of Application and Supporting Documents ® Required unless otherwise noted B. Cover Letter (Required for All Application Packages): ® List all items included in the application package, as well as a brief description of the requested permitting action. 'v Be specific as to the system type, number of homes served, flow allocation required, etc. ➢ If necessary for clarity, include attachments to the application form. C. Application Fee (All New and Major Modification Application Packages): ® Submit a check or money order in the amount of $480.00 dated within 90 days of application submittal. r Payable to North Carolina Department of Environmental Quality (NCDEQ) D. Fast Track (Form: FTA 04-16) Application (Required for All Application Packages): ® Submit the completed and appropriately executed application. y if necessary for clarity or due to space restrictions, attachments to the application may be made. ❑ If the Applicant Type in item 1.2 is a corporation or company, provide documentation it is registered for business with the North Carolina Secreta!y of State. ❑ if the Applicant Type in Item 1.2 is a partnership or d/b/a, enclose a copy of the certificate filed with the Register of Deeds in the county of business. ❑ The Project Name in Item ii.I shall be consistent with the project name on the flow acceptance letters, agreements, etc. ® The Professional Engineer's Certification on Page 5 of the application shall be signed, sealed and dated by a North Carolina licensed Professional Engineer. ® The Applicant's Certification on Page 5 of the application shall be signed in accordance with 15A NCAC 02T .01060). Per 15A NCAC 02T .0106(c), an alternate person may be designated as the signing official if a delegation letter is provided from a person who meets the criteria in 15A NCAC 02T .0106(b). INSTRUCTIONS FOR FORM: FTA 04-16 & SUPPORTING DOCUMENTATION Page I of 3 E. Flow Tracking/Acceptance Form (Form: FTSE 04-16) (if Applicable): ® Submit the completed and executed FTSE form from the owners of the downstream sewers and treatment facility. r Multiple forms maybe required where the downstream sewer owner and wastewater treatment facility are different. i- The flow acceptance indicated in form FTSE must not expire prior to permit issuance and must be dated less than one year prior to the application date. Submittal of this application and form FTSE indicates that owner has adequate capacity and will not violate (;.S. 143- 1 > 67(a) Intergovemmental agreements or other contracts will not be accepted in lieu of a project -specific FTSE. F. Site Maps (All Application Packages): ® Submit an 8.5-inch x I 1-inch color copy of a USGS Topographic Map of sufficient scale to identity the entire project area and closest surface waters. Location of the project (gravity sewer, pump stations & force main) i Downstream connection points and permit number (if known) for the receiving sewer ® Include a street level map (aerial) showing general project area so that Division staff can easily locate it in the field. G. Existing Permit (All Modification Packages): ❑ Submit the most recently issued existing permit. ❑ Provide a list of any items within the pen -nit the Applicant would like the Division to address during the permit modification (i.e., permit description, flow allocation, treatment facility, etc.). H. Power Reliability Plan (Required if portable reliability option utilized for Pump Station): ❑ Per 15A NCAC 02T .0 05(h)(1), submit documentation of power reliability for pumping stations. Y This alternative is only available for average daily flows less than 15,000 gallons per day It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant and is compatible with the station. The Division will accept a letter signed by the applicant (see 15A NCAC 02T .0106(b)) or proposed contractor, stating that "the portable power generation unit or portable, independently -powered pumping units, associated appurtenances and personnel are available for distribution and operation of this pump station." if the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. (Required at time of certification) 1. Certificate of Public Convenience and Necessity (All Application Packages for Privately -Owned Public Utilities): ❑ Per 15A NCAC 02T .01 15(a)(I ) provide the Certificate of Public Convenience and Necessity from the 'Borth Carolina Utilities Commission demonstrating the Applicant is authorized to hold the utility franchise for the area to be served by the sewer extension, or ❑ Provide a letter from the North Carolina Utilities Commission's Water and Sewer Division Public Staff stating an application for a franchise has been received and that the service area is contiguous to an existing franchised area or that franchise approval is expected. J. Operational Agreements (Applications from HOA/POA and Developers for lots to be sold): ❑ Home%Property Owners' Associations ❑ Per 15A NCAC 02T .01 15(c), submit the properly executed Operational Agreement (FORM: HOA). ❑ Per 15A NCAC 02T .01 15(c), submit a copy of the Articles of incorporation, Declarations and By-laws. ❑ Developers of lots to be sold ❑ Per 15A NCAC 02T .01 15(b), submit the properly executed Operational Agreement (FORM: DE`'). For more information, visit the Division's collection sustems weh.sitc iNSTRUC'TIONS FOR FOR\i: FTA 04-16 & SUPPORTING DOCUtIFNTATION Pa,,e 2 of 1 THE COMPLETED APPLICATION PACKAGE INCLDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Reqional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Water Quality Section Swannanoa, North Carolina 28778 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Water Quality Section Fayetteville, North Carolina 28301-5094 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Water Quality Section Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Franklin, Water Quality Section Raleigh, North Carolina 27699-1628 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 788-7159 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Craven, Water Quality Section Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Water Quality Section Wilmington, North Carolina 28405 Hanover, Onslow, Pender (910) 796-7215 (910) 350-2004 Fax Winston-Salem Regional Office 450 W. Hanes Mill Road Alamance, Alleghany, Ashe, Caswell, Davidson, Water Quality Section Suite 300 Davie, Forsyth, Guilford, Rockingham, Randolph, Winston-Salem, North Carolina 27105 Stokes, Surry, Watauga, Wilkes, Yadkin (336) 776-9800 INSTRUCTIONS FOR FORNL FTA 04-16 & SUPPORTING DOCUMENTATION Pa,c 3 of", State of North Carolina Department of Environmental Quality Division of Water Resources -D W. R 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: W Q O0 T 173� (to be completed by DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: 1. Applicant's name: Harnett Regional Water (company, municipality, HOA. utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State -County ❑ Municipal ❑ Other 3. Signature authority's name: Steve Ward per 15A NCAC 02T .0106(b) Title: Director of Harnett Regional Water 4. Applicant's mailing address: P.O. Box 1 119 ' 700 McKinney Parkway City: Lillington State: NC Zip: 27546- 5. Applicant's contact information: Phone number: (910) 814-6473 Email Address: sward( hamett.org IL PROJECT INFORMATION: 1. Project name: Woodo ove Subdivision 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit./Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Harnett 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.49764 Lon,itude:-78.810351 5. Parcel ID Of applicable): 0653-77-4878 (or Parcel ID to closest downstream sewer) 111. CONSULTANT INFORMATION: 1. Professional Engineer: Jim Chandler License Number: 026466 Firm: Timmons Grou[) Mailing address: 5410 Trinity Road, Suite 102 City: Raleigh State: NC Zip: 27607- Phone number: (919) 866-4507 Email Address: iim.chandler(d�timmons.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: North Harnett Regional Waste Water Treatment Plant Permit Number: NCO021636 Owner Name: Harnett Regional Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS000166 Owner Name(s): Harnett Regional Water FORA: FTA 04-16 Page I of 5 VI GENERAL REQUIREMENTS 1. if the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached" ❑ Yes [:]No ®N%A 2. if the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DES') been attached" ❑ Yes [:]No ❑N A 3. If the Applicant is a Hontc Property Owners' Association, has an Operational A!,rccment ( FORM: I10A) been attached'' ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation%service ❑ Hotel and. or Motels ❑ School / preschool ` day care ❑ Medical dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices ' factories ❑ Nursing Home ❑ Other ( Explain in Attachment) 5. Nature of wastewater : 100 °/� Domestic'Commercial % Commercial Industrial (See 15A NCAC 02T .0103(20)) bIs there a Pretreatment Program in effect'? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .0114(t)" ❑ Yes ® No i If ves, provide a coov of flow reduction approval letter 7. Summarize wastewater generated by project: 8 Establishment Type (see 02T.01140)) Daily Design Flow',b No. of Units Flow Single -Family Residential 360 gal/day 230 82,800 GPD gal/ GPD val i GPD gal/ GPD gal/ GPD dal; GPD Total 82,800 GPD a See I iA NCAC02T .01 14tb). (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses: public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .01 14(c), design flow rates for establishments not identified [in table I SA NCAC 02T.01 141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. Wastewater generated by project: 82,800 GPD (per 15A NCAC 02T .01 14) i Do not include future flows or previously permitted allocations if permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORA. FTA 04-16 Pa,e 2 of 5 I VI1. GRAVITY SENVER DESIGN CRITERIA (If Applicable) - 02T .0305 & NIDC (GraNit-, Sewers): I . Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 12,955 PVC 3 209 RJDIP r Section II & 111 of the MDC for Permitting of Gravity Sewers contains information related to design criteria Section III contains information related to minimum slopes for gravity sewer(s) i Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION' DESIGN' CRITERIA (If Applicable) — 02T .0305 & MDC ( Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational points) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T ,0305(h)( I ): ❑ Standby power source or pump with automatic activation and telemetry - I5A NCAC 02T .0305(h)(I )(B)_ i Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day i Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): > It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of IX. SETBACKS & SEPARATION'S — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in I A NCAC 02"f .0305(f) & (,) 0 Yes ❑ No i SA NCAC 02T 0301A contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Stone sewers and other utilities not listed below (vertical) 24 inches Water mains ( vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines ( horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class l or Class Ii impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands (see item 1X.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainages stems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches t S.A NCAC 02T.03051 a) contains alternatives where separations in 0_'T.0305(f) cannot be achieved. i **Stream classifications can be identified using the Division's NC Surface Water Classifications webpa,e if noncompliance with 021'.0305(t) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands'? (50 feet of separation) ® Yes ®No ❑ N/A See the Division's draft separation requirements for situations where separation cannot be meet i No variance is required if the alternative design criteria specified is utilized in design and construction i As built documents should reference the location of areas effected Alternative design meeting 02T.0305(g) provided where not meeting 50' of separation. 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200'! ® Yes ❑ No ❑ N/A This would include Trout Buffered Streams per.] SA NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or El Yes [I No individual permits or 401 Water Quality Certifications'? i Information can be obtained from the 401 & Butter Permitting Branch 401 Action Id. SAW-2008-01427 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits.: certifications)'? ® Yes []No Per 15A NCAC 02T.0I05(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stonrtwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority'?" Per 15.A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ®Yes [I No ❑ NI! A if yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual: System -Wide Collection permit. FORM: FTA 04-16 Pa`c 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with I �,A NCAC' 02 L the Mtrtinrtnrt Desu n Criteria for the Pcrmuttun, of Pnmp Station> and Force 'Main, (latest version ). and the Gravity Sewer Minimum Dcsi,n Criteria ( latest version) as applicable' ® Yes ❑ No If No, complete and submit the Variance.Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: James F. Chandler, Jr. (Professional Engineer's name from Application item 111_I.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: Applicant's Certification per 15A NCAC 02T .0106(b): Y-c c +-p attest that this application for (Signature Authority's name & title from .Application item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. i understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, andior criminal prosecution. i will make no claim against the Division of Water Resources should a condition of this permit be violated. 1 also understand that if all required parts of this application package are not completed and that if all required supporting infunnation and attachments are not included, this application package will be returned to me as incomplete. NOTE — in accordance with General Statutes 14 3-215.6A and 14 3-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: —44 Date: FORM: FTA 04-16 Page 5 of 5 PROJECT NARRATIVE Project Name: Woodgrove Subdivision Location: US 401 N, Harnett County, NC Owner: GreenHawk Corporation, Inc. 1330 Sunday Drive, Suite 10f Raleigh, NC 27607 Developer: GreenHawk Corporation, Inc. 1330 Sunday Drive, Suite 105 Raleigh, NC 27607 Consultant: Timmons Group Jim Chandler 5410 Trinity Road, suite 102 Raleigh, NC 27607 Phone: 919-866-4507 PROJECT DESCRIPTION AND NARRATIVE: The proposed project is inside Harnett County's jurisdictional limits and is located along US 401 N, south of the intersection of SR 1441 (East Williams Street) and US 401 N. The scope of this project will include the construction of a 230 lot subdivision. The project is anticipated to generate the following wastewater flows: 120 GPD/BEDROOM @ 4 BEDROOMS/ UNIT @ 230 UNITS = 110,400 GPD State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Harnett Regional Water Project Name for which flow is being requested: Woodgrove(fonnally Woods a/Lafayette) r More than one FTSE mai be required Jor a single prgject i the owner ofthe IVTVTP is not responsible,fiv all pump stations along the route of the proposed wastovaterJlow. 1. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett Regional WWTP b. WWTP Facility Permit #: NC0021636 A11 flows are in MGD c. WWTP facility's permitted flow 7.5 MGD Fuquay-Varina Allocated Flow 2.60 MGD Lillington Allocated Flow 1.20 MGD Angrier Allocated Flow 1.008 MGD d. Estimated obligated flow not yet tributary to the WWTP 1.228 MGD FV Obligated Flow NYT 0.626 MGD Lillington Obligated Flow NYT 0.113 MGD HC Obligated Flow NYT 0.315 MGD Angier Obligated Flow NYT 0.174 MGD e. WWTP facility's actual avg. flow 4.381 MGD FV Actual Flow 1.180 MGD Lillington Actual Flow 0.648 MGD HC Actual Flow 1.975 MGD Angier Actual Flow 0.578 MGD f. Total flow for this specific request (0.083) MGD* g. Total actual and obligated flows to the facility 5.609 MGD FV Actual Avg. + Obligated Flow 1.806 MGD Lillington Actual Avg. + Obligated Flow 0.761 MGD HC Actual Avg. + Obligated Flow 2.290 MGD Angier Actual + Obligated Flow 0.752 MGD h. Percent of permitted flow used 74.79% *Flow was previously accounted for in section d HC Obligated Flow NYT flows prior to recent DWR recension due to Engineer Design change from the previous approved permit. Page 1 of 4 00 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated. Pump Average Daily Approx. Not Yet Total Current Station Firm Flow** Current Avg. Tributary Flow Plus (Name or Capacity. * (Firm i pf), Daily Flow, Daily Flow, Obligated Available Number) MGD MGD MGD MGD Flow Capacity*** CONTACT TOFV FOR UPSTREAM SLS CAPACITY INFO SLS 120 14.4 5.76 2.5 1.079 3.579 2.181 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): North Harnett Regional WWTP Downstream Permit Number: NCO021636 III. Certification Statement: I Steve Ward certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance Athis wastewater flow. Signing Official Signature .S-- / f'= ), Date Page 2 of 4 1 1'S1: 06-1 1W USGS Maps Property is split between the Fuquay Varina 1993 and Lillingtion 1997. SCALE IM 006 R-ecs, 414R I -T-1 .1 VAP FUQUAY-VARINA, NC STATE OF NORM CAROLHNA DEPAMENFrOf ENVIRONMENT AND NATURAL RESOURCES ULLLNGTON QUADRANGLE DIVI I N Of I AND RESOURCES NOM CAROLINA I+ARNFTTCO _M(AR(1IINA(.R1W(.RAISLRV" ':MINMSEIIMSJOP RAM� V WOODGROVE SITE 14 Woodgrove Subdivision Write a description f• • .• Wk x _ earth, m r ` C,j y C4rr y A ° I ' 4 � � �y �I �• G(Ove Rd Gt, DgXtet •� ��'. O _0 CP hRa. p �. _ram � mil`•, i � � �_, f. Google Earth © 2020 Google `�oSh 4000 ft PROJECT NARRATIVE Project Name: Woodgrove Subdivision Location: US 401 N, Harnett County, NC Owner: GreenHawk Corporation, Inc. 1330 Sunday Drive, Suite 105 Raleigh, NC 27607 Developer: GreenHawk Corporation, Inc. 1330 Sunday Drive, Suite 105 Raleigh, NC 27607 Consultant: Timmons Group Jim Chandler 5410 Trinity Road, suite 102 Raleigh, NC 27607 Phone: 919-866-4507 PROJECT DESCRIPTION AND NARRATIVE: The proposed project is inside Harnett County's jurisdictional limits and is located along US 401 N, south of the intersection of SR 1441 (East Williams Street) and US 401 N. The scope of this project will include the construction of a 230 lot subdivision. The project is anticipated to generate the following wastewater flows: 230 single-family units x 360 GPD = 82,800 GPD Ktutivtu DEQlDWR J U N 10 2020 WQROS FAYETTEVILLE REGIONALOFFICE X GreenHawk Developsrr 11 4* 1330 S ,.,$.wte 105 NC 27607, 0, PATE: j '0" 9 k, 44 7 � VY: 517 20, 2 1', State of North Carolina Department of Environmental Quality D-W,, R Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Dk4slon of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DNR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Harnett Regional Water (company, municipality, HOA. utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ® State:'County ❑ Municipal ❑ Other t<tLtl l tLJ 3. Signature authority's name: Steve Ward per 15A NCAC 02T .0106(b) DEQ/r vVR Title: Director of Harnett Regional Water 4. Applicant's mailing address: P.O. Box 1119 % 700 McKinney Parkway JUnJ �" Z; 3v City: Lillington State: NC Zip: 27546- WQROS 5. Applicant's contact information: �:AYETTEVILLEREGIONA[.OFFICE Phone number: (910) 814-6473 Email Address: sward(i harnett.ore It. PROJECT INFORMATION: 1. Project name: Woodvrove Subdivision 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit'Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Harnett d Annroximate Coordinates (Decimal Degrees): Latitude: 35.49764- Longitude:-78.810351 GreenHawk Development, LLC 1330 Sunday Drive suntrust Bank 51725 Suite 105 25 Park Place Raleigh, NC 27607 Atlanta, GA 30303 DATE: May 20, 2020 919-861-2929 66-46/531 PAY i 0 0ew QNLY i _ : . ... c $ 480.00 PAY Four Hundred Eighty and 00/100 Dollars VOID AFTER 180 DAYS'. TO THE ORDER OF NCDEQ g,40-,".A �.- ___2HECK IS PRINTED ON SECURITY PAPER WHICH INCLUDES A MICROPRINT BORDER & FLUORESCENT FIBERS Owner Name(s): Harnett Regional Water FORM: FTA 04-16 Pa,,c 1 of 5 DECK/DWR TIMMONS GROUP YOUR VISION ACHIEVED THROUGH OURS. WOROS FAYETTFVILI_F.s?C�C�NA[.. TRANSMITTAL 1�25 CA'C^ S-k- RalPiph NC 27Rn3 - 5y:.�t -1 k4 (-S.�J�tcv►kc , c� c, 2f63v� ® ENCLOSED PLEASE FIND: All ❑ WE ARE SENDING UNDER SEPARATE COVER: Date: 05/20/2020 Job #:41015 Project: Woodgrove Subdivision Reference: Copies Sent To: COPIES DATE NUMB DESCRIPTION 1 4/9/2020 1 Sets of Construction Drawings 1 5/15/2020 2 Fast Track Application 1 3 Check for $480 payable to DEQ — Public Water Supply Section 1 5/15/2020 4 Cover Letter / Project Narrative 1 5 FTSE Flow Tracking/Acceptance Form 1 6 USGS To o Maps 1 7 Aerial Ma THESE ITEMS ARE TRANSMITTED: All If enclosures are not as noted, please notify us at once. COMMENTS: Please feel free to contact me with any questions at 919-532-3237 or dave.ballentinea-timmons.com Thank you, Dave Ballentine Project Manager SIGNED: 71V' M 1.0 ko Oi U" X LL 0) rn w E 0 v vi C 0 E E Permit Number W00041736 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer stephanie.zorio Coastal SWRule Permitted Flow 82,800 Facility Facility Name Woodgrove Subdivision Location Address Owner Central Files: APS _ SWP _ 6/10/2020 Permit Tracking Slip Status Project Type Active New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Major/Minor Region Minor Fayetteville County Harnett Facility Contact Affiliation Owner Name Owner Type Harnett Regional Water Non -Government Owner Affiliation Steve Ward Director Interim Public Utilities of PO Box 1119 Dates/Events Lillington NC 2754611' Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 6/10/2020 5/26/2020 6/10/2020 6/10/2020 Regulated Activities Requested /Received Events Wastewater collection Additional information requested Additional information received Outfall Waterbody Name Streamindex Number Current Class Subbasin