Loading...
HomeMy WebLinkAboutWQ0032700_Regional Office Historical File 2011FF WEST CONSULTANTS, PLLC Consulting Engineers and Surveyors 405 South Sterling Street Morganton, North Carolina 28655 Phone (828) 433-5661 Fax (828) 433-5662 TO NCDENR - DWQ (Asheville) 2090 US Highway 70 Swannanoa NC 28778 WE ARE SENDING YOU X Attached Under separate cover via Shop drawings Prints Plans Copy of letter Change order Other: LETTER OF TRANSMITTAL JOB NUMBER/PHONE DATE 07216 6/20/2011 ATTENTION RE: Triple H Construction (Jason Haire) - Covington Place Phase IV Sanitary Sewer Project in Town of Cajah'sMountain (Permit No. WQ0032700) the following items. Specifications Samples COPIES DATE NUMBER DESCRIPTION 1 1 Engineering Certification As -Built Plans THESE ARE TRANSMITTED as checked below: For your approval X For your use As requested For review and comment FOR BIDS DUE/DATE: Approved as submitted Approved as noted Returned for corrections Other 6/20/2011 REMARKS �k,'�� c, Lv'LS••t-C'o1�S'� l'•��-t'tS� �� r COPY TO SIGNED ff enclosures are not as noted, please notify us at once. PRODUCT 13127G USE WITH 771C ENVELOPE Deluxe For Business 1-800-225-6380 or www.nebs.com Resubmit copies for approval Submit copies for distribution Return corrected prints PRINTS R PRINTED IN U.S.A. A A ENGINEERING CERTIFICATION — POST CONSTRUCTION System Description: 3449.69 linear feet of 8-inch diarneter gravity sewer Complete and submit this form to the Asheville regional office with the following: One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are required for any changes resulting in non-compliance with this permit, regulations or minimum design criteria. This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEERS CERTIFICATION ❑ Partial PfFinal 'v� T11vw,Gs , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (�riodically, ❑ weekly, ❑ full time) the construction of the above referenced project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2H .0200; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria.for the Fast -Track Permitting of Pump Stations and Force Mains adopted jurre 1 2000 as applicabte and other supporting materials. -- North Carolina Professional Engineer's seal, signature, and date: 00000eeieoeeeoe gi CAiR®t',,°°soy ®'�' �kE3S1®� �'� •40 9 SEAL s 210757 c JUN 21 2011 T. EN TH16,jFIQ3RMJ&L96F5§b'T'��71 LG D CUMENTATION WITH REQUIED ATT?1WING ADDRESS v te_:::>r �:ti .s .:__>.,,.... 'ROGER" EDWARDS SURFACE WATER PROTECTION SUPERVISOR ASHEVILLE REGIONAL OFFICE 2090 US HIGHWAY 70 SWANNANOA, NC 28778 The P /rmittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow madtributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions.