Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0041680_Application (FTSE)_20200511
State of North Carolina Department of Environmental Quality Division of Water Resources DWR 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: PJ 00q W V (to pc compleudby DWR) All items must be completed or the application will be returned 1. APPLICANT INFORMATION: L Applicant's name: City of Mebane (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State. County ® Municipal ❑ Other 3. Signature authority's name: David Cheek per I5A NCAC 02T .0106(b) Title: City Manager 4. Applicant's mailing address: 106 East Washington Street City: Mebane State: NC Zip: 27302- 5. Applicant's contact information: Phone number: U 563-5901 Email Address: dcheek@citvofmebane.com II. PROJECT INFORMATION: Z 1. Project name: Bowman Village (phase N1 & N2) 0 tv :.. 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project cu c If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 CD a 3. County where project is located: Orange 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.068992 Longitude:-79.245105 t" 5. Parcel ID (if applicable): PIN# 9824-74-D28 & 9824-73-6163 ,0 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Charles P. Koch License Number: NC 9022634 Firm: EarthCentric Engineering Inc. Mailing address: 204 We§t Clay Street City: Mebane State: NC Zip: 27302- } Phone number: 919 563-9041 Email Address: Phi l.KochQEarthCentric.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: L Facility Name: City of Mebane WRRF Permit Number. NCO021474 Owner Name: City of Mebane V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 8 inch System Wise Collection System Permit Number(s) (if applicable): WQCS00081 Owner Name(s): City f Mebane FORM: FTA 04-16 Pagel of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N A 2. if the Applicant is a Developer of lots to be sold, has a I . eveloner's Operational Agreement (FOF %1: L EV) been attached? ❑ Yes ❑No ®N A 3. If the Applicant is a tome Property,Owners' Association has an Operational A ree-1,ent FOkhi: HOA been attached? []Yes [-]No ®N A 4. Origin of wastewater. (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 1000o Domestic/Commercial % Commercial % Industrial (See 15A NCAC 02T .0103(20)) a Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under I SA NCAC 02T .01141f1? ® Yes (]No D If yes, provide a coat/ of flow reduction anaroval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0I14ff)) Daily Design Flow',b No. of Units Flow single-family home, 4-bedroom 320 gal/day 49 15,680 GPD gall GPD gall GPD gal GPD gall GPD gal/ GAD Total 15,680 GPD a See 1 N AC 02T .0114 d e I and e 2 for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table i 5A NCAC 02T.0 i 14] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: ` GPD (per 15A NCAC 02T .0114) D Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & .'vtDC Gravity Sevrers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 1,107.70 SDR-21 8" 1,157.51 Ductile Iron D Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria D Section III contains information related to minimum slopes for gravity sewer(s) D Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. .Pump station number or name; 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305 1 : ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. D If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 1X. SETBACKS & SEPARATIONS — (02B .0200 & I5A NCAC 02T .0305(0): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(n & (e) ® Yes ❑ No D 15A NCAC 02T.0305(f) contains minimum sennratinna that chap hw nrovideri fnr easy e.,et.— Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches) Water mains(horizontal) 18 inches 10 feet Reclaimed water Iines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet "Any private or public water supply source, including any wells, WS-1 waters of Class I or Class 11 impounded reservoirs used as a source of drinking water 100 feet *"Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Toe slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools Final earth Srade vertical 10 feet 36 inches D 15A NCAC 02T.0305(s) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications weboagc ➢ If noncompliance with 02T.0305(f) or (&L see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ® No ❑ N A D Seethe Division's draft separation requirements for situations where separation cannot be meet D No variance is required if the alternative design criteria specified is utilized in design and construction D As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02f3 .0200? ❑ Yes ❑ No ® N A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? D Information can be obtained from the 401 & Bui'rer Permitting branch 5. Does project comply with 1 A NCAC 02T.0105 c 6) (additional permits certifications)? ® Yes ❑ No Per 15A NCAC 02T. 105 c 6 directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402. "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that underm ines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-I6 Page 4 of X. CERTIFICATIONS: Does the submitted system comply with 15A NCAC 071, the Minjrnupt 1,)rsign Cri eriit fofor lheitlnjlt}pg of P�rJr p_.9 t� ians and Force Nigins (latester;'a� and the ciravii �ew.er Minimum Drsi n Crilerla (latest version) as applicable" ® Yes ❑ No If No, complete and submit the Variance/Altemative Design Request application (VADC 10-14) and supporting documents for review. Approval of the reguest is re uired prior to submittal of the Fast Track Apnlication and supporting documents. 2. Professional Engineer's Certification: _ attest that this application for (Professional Engine: is name from Application Item I1I.1,) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that 1 have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and da 3. Applicant's Certification per 15A NCAC 02T .0106(b): 1, David S. Cheek, City Manager attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes - 3-215 6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S I0,000 as well as civil penalties up to $25,000 per violation. D.S.Cheek Signature: " ' • Date: 4/29/2020 FORM: FTA 04-16 Page 5 of 5 204 West Clay Street Mebane, NC 27302 Phone; (919) 563-9041 Fax: (919) 304-3234 H n.. Inc. Project: Bowman. Village (phase N1 & N2) Page 1 of l ECE Project # 19-008 Information provided by: Shawn C. Sidener Cover Letter, wastewater flow calculations and project narrative for NCDEQ, Division of water Quality Fast -Track Sewer System extension application. Proiect Narrative: The Bowman Village, Phase N 1 & N2 project consists of a new 49 lot subdivision (which is part of a larger 177 lot subdivision) with associated public roadways, utilities, open space, drives, parking, etc. being built on two parcels of land totaling 68.64 acres. Future phases will be submitted at a later date. The homes will be a mix of three- and four -bedroom models. The site is located in the vicinity of 7117 Bowman Road, Mebane North Carolina with this portion of the site being north of Bowman road. It can be identified with PIN# 9824-74-5328 & 9824-73-6163. The development of this subdivision will require a public sewer extension to tie into the City of Mebane sewer system. This portion of the gravity sewer extension will consist of 16 new manholes and 1,107.70 If of 8" SDR-35, PVC and 1,157.51 If of 8" ductile iron pipe (DIP). The new sewer main will tie into a City of Mebane 8" ductile iron sewer main at a manhole. Wastewater Flows: -4 bedroom residential homes = 80* gal Ions.-'day/bedroom with a 160* gallons/day min. (Exact mix unknown, calculated at highest possible volume) * See attached Flow Reduction Approval for the City of Mebane 49 homes x 4 bedrooms x 80 gallons 15,680 gaIlons/day Total Wastewater Flow = 15,680 gallons / day Items included with this package: one original and one co Cover letter Application fee of $480.00 - Fast -track Application Flow Tracking / Acceptance Form - USGS Map - Street level Map City of Mebane Flow Reduction Approval CDept ofEnyironmental Qualiry MAY 1 2020 Raleigh Regional O flee . ....................... State of North Carolina Department of Environmental Quality Division of Water Resources Msion of Water Resourc s Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: City of Mebane Project Name for which flow is being requested: Bowman Village More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Ci of Mebane b. WWTP Facility Permit #: NC0021474 c. WWTP facility's permitted flow d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used All flows are in MGD 2.500 .670 1.597 0.016 2.267 91% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) Design Pump Average Daily Station Firm Flow** (Name or Capacity, * (Firm / pf), Number) MGD MGD SE Reg. 2.5 1.0 (B) (C) (D)=(B+C) (E)=(A-D) Obligated, Approx. Not Yet Total Current Current Avg. Tributary Flow Plus Daily Flow, Daily Flow, Obligated Available MGD MGD Flow Capacity*** 0.217 0.245 0.462 0.539 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): City of Mebane Downstream Permit Number: WQ0039116 Page I of 6 FTSE 04-16 III. Certification Statement: I David Cheek certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow. 5I2I20 Signing Qjcial Signature Date 4, Page 2 of 6 FTSE 04-16 I 2 2j I- ;a as de m LL) sin f., j L -A, id, z ILI "j i, ID 0 Zg Lo in 100 �'. % '••• f u� a 5 f �I�1 � - /,/fl W .,,' J 1$ �; _.. ,,I F v? : ^ •�.� • +� si CD Is N1 �Z V9-- F S Lit LL 2 LU w Lu avow% T-e LLJ Z Z 0 Lu LU . :ice ...0-s > z Lu a. ri u�;lap-JESA�' V_ aim , ria NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Govemor Director March 15, 2011 Robert L. Wilson City Manager City of Mebane 106 East Washington Street Mebane, NC 27302 Subject: Mebane WWTP (NC0021474) Flow Reduction Request Alamance County Dear Mr. Wilson: Dee Freeman Secretary On February 14, 2011, the Pretreatment, Emergency Response and Collection System (PERCS) Unit of the Division of Water Quality received a flow reduction request for connections to the City of Mebane WWTP. The letter requests an allowable flow rate of 80 gallons per day (gpd) per bedroom based on the evaluated data As daily WWTP data is not representative of the project area, the DMR data from the City of Mebane WWTP (NC0021474) from January 2009 through December 2009 was evaluated to determine the peak sewage month. The highest flow month was December 2009. Daily wastewater flows were recorded downstream of the Holly Ridge Subdivision during December 2010. This data was reviewed by PERCS and Regional Office staff. Based on the data, the Division hereby grants a reduction in flow to 80 gpd/bedroom (minimum of 160 gpd for 1 and 2 bedroom residences) for sewer extension permits issued tributary to the City of Mebane WWTP. Regardless of the adiusted design daily wastewater flow rate, at no time shall the wastewater flows exceed the effluent limits defined in the NPDES permit for the treatment facility or exceed the capacily of the sewers downstream of any new sewer extension or service connection(s). If you have any questions or comments regarding this matter, please contact Sarah Morrison at (919) 807-6310, or email [Sarah.Morrison@ncdenr.gov] or Deborah Gore, Unit Supervisor at (919) 807-6383, or email [Deborah.Gore@ncdenr.gov]. Sincerely, -�p f Coleen H. Sullins cc: Darrell L. Russell, P.E., Alley, Williams, Carmen & King, Inc. (via email: dnwell©awck.com) Steve Mauney, Winston-Salem Regional Office (via email) NPDES Unit, Permit File NCO021474 PERCS Flow Reduction File 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Location- 512 N. Salisbury SL Raleigh, North Carolina 27604 ne Phone 919-007-63001 FAX: 919-807-64921 PERCS Vnit FAX: 919-807.64691 Customer Service:1-877-623.6748 copAhCarol lIle Internet hMd/partal.ncdenrorpArteblwal PERCS Unit http:.Yportal.ncdenr.orQArebAvaJs Wgypret An EVS Opporturily 1 Affirmative Action Employer — Robinson, Jason From: Tim McAvinney <Tim.McAvinney@EarthCentric.com> Sent: Tuesday, May 26, 2020 12:24 PM To: Deck, Erin M Cc: Phil Koch; Shawn Sidener; David Cheek (dcheek@cityofinebane.com); Robinson, Jason Subject: (External] RE: Bowman Village (phase N1 & N2) Fast track sewer extension Attachments: 19-008 Working S1.0 Offsite Sewer 2020-05-26.pdf + Exterl: e namail. Do not ahCk (Inks or open attachments.unless you verify. Send all. suspicious etnall'as a> attar amen to NSIRV Erin, I've attached the relevant plan and profile drawing so that you can see what's going on with regard to those checked boxes on the application. We are crossing under a stream with a sewer bore at the indicated location. Where the sewer makes a perpendicular crossing of the stream we pass between two small wetland areas at a distance of less than 50 feet from both. To mitigate this we are: • Performing a perpendicular crossing, not paralleling the stream or the wetlands. • Boring under the creek with an encasement pipe. The bore pit is outside of the Zone 1 stream buffer. • Constructing the line between MH-Al and EX MH-3 to water main standards with Class 50 pipe and testing to 150 psi, per the Minimum Design Criteria for Gravity Sewer document. • The pipe at the crossing itself within the encasement is restrained joint pipe, again per the Minimum Design Criteria. Also, we did check "no" on the high priority line question as there is no aerial sewer, nor are we contacting the stream. Again, the crossing is perpendicular to the stream, and keeps our disturbance outside of the sensitive stream bank areas and places all of the appropriate erosion control measures on the perimeter of the disturbed area. As you can see there are no pipes parallel to the stream that are subject to erosion. Does that answer your questions? If not feel free to call our office or we can set up a zoom meeting to discuss the design. Sincerely, �511t111i] ?&Wffv� N. X ;404f W# Civil Designer, CAD/IT Manager EarthCentric Engineering, Inc. 204 W. Clay Street Mebane, NC 27302 E-Mail: Tim. McAvinneyOEarthCentric.com Web: www.EarthCentric.com fearthcentric.com) Voice: (919) 563-9041 Fax: (919) 304-3234 From: Phil Koch <Phil.Koch@EarthCentric.com> Sent: Tuesday, May 26, 2020 10:44 AM To: Shawn Sidener <Shawn.Sidener EarthCentric.com> Subject: FW: Bowman Village (phase N1 & N2) Fast track sewer extension From: Deck, Erin M <erin.deck@ncdenr.g_ov> Sent: Tuesday, May 26, 2020 10:33 AM To: dcheek cit ofinebane.com; Phil Koch <Phil.Koch@EarthCentric.com> Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov> Subject: Bowman Village (phase N1 & N2) Fast track sewer extension Good Morning, We are reviewing the subject application and have the following questions: Item IX.2 is check "no" for meeting wetland separation requirements. Please explain. Item IX.6 is checked "no" for high priority lines. Please confirm that no lines in this project will be aerial lines, contacting surface waters, or will be positioned parallel to streambanks that are subject to erosion. Thank you, Erin Deck Department of Environmental Quality Division of Water Resources Raleigh Regional Office Office: 919-791-4258 Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties.