Loading...
HomeMy WebLinkAboutNCG550475_Regional Office Physical File Scan Up To 6/3/2020 Facility information NPDES permit #: NCG5510475 Buncombe County Facility name: Victor Babaoff SFR (single family residence) WWTP type: 480 gpd SFR facility (4 bedrooms) consisting of: 1200 gallon septic tank; distribution box; 6 ft x 87 ft sub-surface sand filter; tablet chlorinator; 130 gallon chlorine contact chamber (with 30 minute detention time); pump tank with pump & power supply; and discharge to creek. A to C: Authorization to Construct issued 6-7-1989. Engineer: Roger M. Lyda, P.E. WWTP location: 308 Secretariat Lane (in Churchill Downs Subd.); off Hwy 74 in Fairview (gated community) Responsible official: Victor Babaoff Responsible " 's title: owner Official's location: 308 Secretariat Lane Fairview, NC 28730 Mailing address: 308 Secretariat Lane Fairview, NC 28730 Phone numbers 828- Victor Babaoff 828-582-5994 - cell Permit information Date issued: 8-1-07 Expiration date: 7-31-12 Last inspection: 8-10-11 by WPF (sent certified lab & testing info) Sampling: Performed on 9-15-2011 by ETS (Kelley Keenan @ 350-9364). WPF faxed ETS the permit (fax: 350- 9368). Mr. Babaoff came by the lab & picked up the sample bottles. Stream information Stream: UT to Reed Creek (Spivey Lake) River basin: French Broad River Basin Sub-basin: 04-03-02 Hydrologic Unit Code: Quad: Grid: Latitude: Longitude: Stream classification: WS — III Trout Drainage area sq mi: 0.42 Instream Waste Conc.: Average stream flow: cfs Summer 7Q10 cfs Winter 7Q10 cfs 30Q2 cfs: Other information Directions: System is behind the left side of the fence in the backyard. Permit requirements: Part 1.A. Required annual monitoring / analyses (analyses must be performed by a NC certified lab) and limits for: Parameter Sample type Permit Limits Flow estimate BOD grab 30 mg/I monthly average / 45 mg/I daily maximum TSS grab 30 mg/I monthly average / 45 mg/I daily maximum Fecal coliform grab 200 col/ml mo. ave. / 400 col/ml da. max. *TRC grab 17 ug/I (*TRC = Total residual chlorine) -� �---y Page 1 of 2 f / Notes MAPQMGS'T Victor BabaoB - �=e!! • fi8 .�2 -.5 7%`f. SFR NCG55045 Trip to 308 Secretariat Ln — Fairview,.NC28730-9765 9.89 miles -about 14 minutes 1 1 L� /Y/ay IOIVL T")-- '�7i' 40 2090 Us 70 Hwy Swannanoa NC 28778 8211 ® 1. Start out going west on US-70 toward New Salem Rd. go 2.4 mi 2. Turn left onto Porter Cove Rd. go 0.1 mi 3. Merge onto 1-40 W toward 1-26/Asheville. go 2.4 mi war 4. Take the US-74-A E exit, EXIT 53A,toward Blue Ridge go 0.2 mi �+^^--^^�� Pkwy/Bat Cave. L, 5. Merge onto US-74-ALT. go 4.4 mi ®® 6.Turn left onto Churchill Downs or(Gate access go 0.2 mi required). 7. Tom left onto Secretariat Ln. go 0.0 mi ® 8. 308 SECRETARIAT LN is on the left. go 0.0 mi 308 Secretariat Ln Fairview NC 28730-9765 - vn e- a e5 0 Total Travel Estimate : 9.89 miles-about 14 minutes pn Y O P50A 6 () 6 c/ ' /iVL. IV oZ g016 Route Map Hide http://classic.mapquest.com/print 8/9/2011 my i.. � i �>n 4 � � fi .d 4 i j s't� �"ae*'s � t 4"�t��( ��` ,P)�+��� 15'S� �jx4 i 1 � k r �' � pb 3 � a v�. � 5 k i *� d .n " ' � }�'� v E 5 � ��' V �`11 � �� 1 �� � g3 „� � �d' y"'k�:u��,�l� (14'� � this �Iw p' t ..r9 `` x. n „,. 71z'' + �a� t'd � � i'`.�h. s � � � h �� � �. 'lk � � 1 s �.=a�' 1 �} a" r ai�i t yx11�� �} fN. 316 rfi �Y � 9�oi � �� i t 4 �� � eat ��� ��i ai�n°�°� + �� fka ,� i��.� � J i � r! 7 � t� " s� +a�2 „� t� r �� ��„ �3 2Fit � ; b�l k'ptL�7 � -0 } t#� I � { f. �� �I �V � b u� i` &q�L.t-y � Y I�'➢ r f�� � � � �� �,7y9+� � a�i � ar � �a "kF�d'��`�C"iY7�"p��T ' ,ryE��IIyf�'� �, k r � �i�. �� �'� � -,4ba"! �smd� � f�L.�, 4'�a rx�tJ� bk j � " y °� r c a�� }, ,y '� 7 1—A�� i � � 1 r$s � � its��� ut v ,U Jr � �iFde�w F .J� iF�E' �^ � t!n � 4 t *° ��i�4'� r ���"�� Y� '.�'K�"��v� e4 t'`r'�iY °'�# rx. s �"' ,�h H i wG. ^i 1 t' sn"I N t "r'P �i �+.i.t 7 �� L�J Fx vh ,�t1 � t s Pfl{e Y ✓ � t2 1 Jw+s � t � - , A" iAvs ama�,k "�` "��`s t� 1 � ,:; , r�`"�7 }}t."�=.�f kp r' '� '�"�rm ,. q' 'sz ' , x 9 � sttFl�t "�Y' is �.��rPr����J s"' � z�'?�:Y� ��v L� '� "°"� .' � ' � 43t�hkta a �� ��``� � �� Kai "� �'��, "`r�, „ , I � '���'��� �� '��. F �a � .� _ - �• �• � � � 1 : /\ bun omp county �f \. V ~ / 7 � / d . ? 0 m a e m m Feet / �,fC �r� R QA�3 �C�� r R�si�z�acr-_ / /i /` 9 \� _ �. RECEIVED Sit` P 11 / V C� l}'-� b V l water pualit9 Sectiot Y -4 RECEIVES JUF1121989 APR �g 1989 ,Asheville RBshoaal olncp 946ae 'ER MITSRfM,fINE'" Asheville. North Caroling 00 . Dave\n4rn u.� � O i v- a 7 11 r V d CascAalc 11 r � C1� � vrrvtAtor Cl+ �ur ant \�^ `$ova SayQi�'TS+�k W.8 C� N aus� #30 3 Drwe Cifg WA� 1� Wn'Yer Sw p1 Y>� Sccr4�a. Lame Buncombe County Tax Lookup "--�erty Card ) Page 1 of 2 COUNTY OF BUNCOMBE, NORTH CAROLINA Web Property Record Card 9676-98-1882-00000 Date Printed: 8/9/2011 Owner Information Parcel Information Total Property Value: 362,700 Status: Active Owners: VICTOR BABAOFFAccount: 8149329 TRUSTEE Deed Date: - 8/15/2000 Address: C/O WNC TIRE COMPANY Deed Book/Page: 2322/ 0721 PO BOX 6o69 Plat Book/Page: 0050/ 0099 ASHEVILLE NC 28816 Legal Reference: WARRANTY OR SPL/COMP Property 308 SECRETARIAT LN TRANSFER Location: Location: 3o8 SECRETARIAT LN Tatting Districts Class: RESIDENTIAL County: Buncombe County eighborhood: FAIRVIEW DOWNS SUBD ty ty ubdivision: FAIRVIEW DOWNS City: ub Lot: 68 Fire: FAIRVIEW FIRE oning: School: Conservation/Easement:N ood: Ownership History Transfer Deed Vacant Seller Date Price Legal Reference Book/Page Qualified When Account Names Sold WARRANTY OR BABAOFF 08/15/00 $0 SPL/COMP 2322 / 0721 No: C No 8o63600 WCTOR TRANSFER Assessment History Year Account Acres Land Bldgs IO prr Assessed Desc Exemptions Deferred Taxable 2011 8149329 0.74 43,400 319,300 0 362,700 0 0 362,700 2oio 8149329 0.74 43,400 319,300 0 362,700 0 0 362,700 2009 8149329 0.74 43,400 319,300 0 362,700 0 0 362,700 2008 8149329 0.74 43,400 319,300 0 362,700 0 0 362,700 2007 8149329 0.74 43,400 319,300 0 362,700 0 0 362,700 2oo6 18149329 0.74 143,4001319,30010 362,700 1 10 0 362,700 40.74 0.74 38,600 252,800 0 291,400 0 0 291,400 0.74 38,600 252,800 o 291,400 0 0 291,400 0.74 38,6o0 252,800 0 291,400 0 0 291,400 0.74 38,6o0 252,800 0 291,400 0 0 291,400 0.74 2o,600 248,500 0 269,1oo 0 0 269,ioo nd Data Total Acres: o.74 Land Value: Other Value: o Acres oo Improvements egment# Units Description 10.74 Acres LOT http://www.bmeombetax.org/PropertyCard.aspx 8/9/2011 Buncombe County Tax Lookup r'.,.'perty Card i---� Page 2 of 2 Building Structures Res. Style Sq Bsmt Bsmt Year Grade Condition Value Building ID Feet SgFt Finished Built 1 Y CONVENTIONAL 3146 1573 0 1989 C N 319300 CONV Refinement Description Built-Ins Units Foundation CONVENTIONAL Full Bath(s) 3 Roof TY/MT GABLE W/COMP. SHGL. Half Bath(s) 1 Roof Structure WOOD JOIST Fireplace/Gas Log 1 Floor Finish W/W CARPET Bedrooms(s) 3 Interior Finish DRYWALL/SHEETROCK Heating HEAT PUMP Air Condition COMBINED SYS/HT PUMP Section SgFt # Stories aoom BASEAREA 1573 2.00 UTILITY ROOM1S r.00 WOOD DECK 20 1.00 GARAGE 836 1.00 OPEN PORCH 120 1.00 WOOD DECK 216 1.00 Total Building Value: 319,300 http://w .bmcombetm.org/PropertyCud.aspx 8/9/2011 r� LI 4 �e i F qY I i CL,6;f•N(il�f =��}i:k=1115 a fr1,I C Y �I, ;+d•Pi�liry I I�` I I m ., . r 11U I NCDENR North Carolina Department of Environment and Natural Resources Division of water Quality Michael F. Easley, Governor William G. Ross,in,Secretary Colson H.Sullins, Director July 27,2007 Victor Babaof£ 308 Secretariat Ln Fairview,NC 28730 Subject: Renewal of coverage/General Permit NCG550000 308 Secretariat Lane Certificate of Coverage NCG550475 Buncombe County Dear Permittee: In accordance with your renewal application [received on January 22,2007],the Division is renewing Certificate of Coverage(CoC)NCG550475 to discharge under NCG550000. This CoC is issued pursuant to the requirements of North Carolina General Statue 143-215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated May 9, 1994 [or as subsequently amended]. If any parts,measurement frequencies or sampling requirements contained in this General Permit are unacceptable to you,you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made,the certificate of coverage shall be final and binding. Please take notice that this Certificate of Coverage is not transferable except after notice to the Division. The Division may require modification or revocation and reissuance of the certificate of coverage. Contact the Asheville Regional Office Prior to any sale or transfer of the nermitted facility- Regional Office staff will assist you in documenting the transfer of this CoC. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning the requirements of the General Permit,please contact Toys, Fields [919 733-5083,extension 551 or tova fields@ncmail nett or Susan Wilson [919 733-5083, extension 510 or susan a wilson@ncmail nett. ,Sincerely, for Colson H. Sullins cc: Central Files Ksheville Regional Grace/Surface Water Protection) t1 1 1 NPDES file /JUI � I i 1617 Mail Service Center,Raleigh,Noah Carolina 27699.1617 One 512 Noah Salisbury Street,Raleigh,North Carolina 27604 Nx CarOhna Phone: 919 733-5083/FAX 919 733-0719/Internet:w .ncwaterquality.org tmi l��lf An Equal Opportunity/A@rmative Action Employer—50%Recycled/l0%Post Consumer Paper 7 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NCG550000 CERTIFICATE OF COVERAGE NCG550475 DISCHARGE OF DOMESTIC WASTEWATER FROM SINGLE FAMILY RESIDENCES AND OTHER 100% DOMESTIC DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215,1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission,and the Federal Water Pollution Control Act,as amended, Victor Babaoff is hereby authorized to discharge domestic wastewater [480 GPD] from a facility located at 308 Secretariat Lane Fairview Buncombe County to receiving waters designated as an unnamed tributary to Reed Creek (Spivey Lake) in subbasin 04-03-02 of the French Broad River Basin in accordance with the effluent �. limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. I This certificate of coverage shall become effective August 1, 2007. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day July 27, 2007. for Colson H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission F I General Permit NCG550000 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NCG550000 DISCHARGE OF DOMESTIC WASTEWATER FROM SINGLE FAMILY RESIDENCES AND OTHER 100% DOMESTIC DISCHARGES WITH SIMILAR CHARACTERISTICS UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, this permit is hereby issued to all owners or operators, hereafter permittees, which are covered by this permit as evidenced by receipt of a Certificate of Coverage by the Environmental Management Commission to allow the discharge of treated domestic wastewater in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV hereof. This permit shall become effective August 1, 2007. This permit shall expire at midnight on July 31, 2012. ORIGINAL SIGNED BY SUSAN A. WILSON Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission Page 1 of 11 Pages C General Permit NCG550000 PART I MONITORING, CONTROLS, AND LIMITATIONS FOR PERMITTED DISCHARGES A. EFFLUENT LIMITATIONS AND MONITORING REQUIREMENTS During the period beginning on August 1, 2007 and lasting until expiration, the Permittee is authorized to discharge domestic wastewater from outfall 001. Such discharges shall be limited and monitored by the Permittee as specified below: Flow Annually Estimate llEffluent BOD, 5-Day, 20°C3 30.0 mg/1 45.0 mg/l Annually Grabluent Total Suspended Solids3 30.0 mg/1 45.0 mg/1 Annually Grabluent Fecal Coliform3 200 / 100 ml 400 / 100 Annually Grabluent (Geometric mean) ml Total Residual Chlorine3 Annually Grab Effluent 1. Effluent is defined as wastewater leaving the treatment system, prior to discharge into a creek or other waterbody. 2. The wastewater discharge flow from this facility may not in any case exceed 1000 gallons per day. 3. A North Carolina certified laboratory must perform the wastewater analysis. 4. Instream chlorine levels are not to exceed 17 pg/L. The sample shall be taken from the effluent pipe, prior to discharge into a creek or other waterbody. Treatment system requirements for existing (previously constructed) systems: Septic tank, sand filter, and disinfection. All facilities adding chlorination after the August 1, 2007 effective date of this permit will also be required to add dechlorination. I Treatment system requirements for new(not yet constructed) systems: Septic tank(with riser), primary &secondary (or recirculating) sand filters, chlorination/dechlorination (or equivalent means of disinfection), and post-aeration apparatus. The tablet chlorinator and dechlorinator [if applicable) shall be inspected weekly to ensure there is an adequate supply of tablets for continuous&proper operation. The dechlorinator unit shall be labeled "dechlorination only". The permittee must conduct and document the following maintenance activities: • Septic tanks shall be maintained at all times to prevent seepage of sewage to the surface of the ground. • Septic tanks will be checked at least yearly to determine if solids must be removed or if other maintenance is necessary. • Septic tanks shall be pumped out within three to five years of the issuance date on the Certificate of Coverage. • Contents removed from septic tanks shall be disposed at a location and in a manner compliant with all local and state regulations. • Surface sand filters, disinfection apparatus and (if applicable) dechlorination apparatus shall be inspected weekly to confirm proper operation. • Annual sampling data shall be retained onsite for a minimum of three years. There shall be no discharge of floating solids or foam visible in other than trace amounts. p Page 2 of 11 Pages General Permit NCG550000 PART II STANDARD CONDITIONS FOR NPDES PERMITS SECTION A. DEFINITIONS 1. Permit Issuing Authority: The Director of the Division of Water Quality. 2. Division: The Division of Water Quality in the North Carolina Department of Environment and Natural Resources. 3. EMC: North Carolina Environmental Management Commission. 4. Permittee: The entity who obtains coverage under this General Permit by subsequent issuance of a"Certificate of Coverage" by the Division. 5. Act or "the Act": The Federal Water Pollution Control Act, also known as the Clean Water Act, as amended, 33 USC 1251, et. seq, 6. Concentration Measurements a. Monthly Average Concentration: The sum of the concentrations of all daily discharges sampled and/or measured during a calendar month on which daily discharges are sampled and measured, divided by the number of daily discharges sampled and/or measured during such month (arithmetic mean of the daily concentration values(. The daily concentration value in the case of grab samples is the arithmetic mean (weighted by flow value) of all the samples collected during that calendar day, b. Monthly Average Concentration for Fecal Coliform: The geometric mean of the counts for samples collected during a calendar month. This limitation is identified as"Monthly Average" in Part I of the permit. c. Daily Maximum Concentration: The concentration of a pollutant discharge during a calendar day. If only one sample is taken during any calendar day the concentration of pollutant calculated from it is the "Maximum Daily Concentration". It is identified as "Daily Maximum" in Part I of the permit. 7. Grab Samples: Individual samples of at least 100 ad collected over a period of time not exceeding 15 minutes. Grab samples can be collected manually. 8. Calculations a. Geometric Mean: The Nth root of the product of the individual values where N is equal to the number of individual values. The geometric mean is equivalent to the antilog of the arithmetic mean of the logarithms of the individual values. For purposes of calculating the geometric mean, values of zero (0)shall be considered to be one(1). 9. Hazardous Substance: Any substance designated under 40 CFR Part 116 pursuant to Section 311 of the Clean Water Act. 10.Toxic Pollutant: Any pollutant listed as toxic under Section 307(a)(1) of the Clean Water Act. 11. 13 amass:. The intentional diversion of waste streams from any portion of a treatment facility (including the collection system(. The permittee may allow any bypass to occur which does not cause effluent limitations to be exceeded, but only if it also is for essential maintenance to assure efficient operation. Page 3 of I I Pages General Permit NCG550000 12. Severe Property damage: Substantial physical damage to property, damage to the treatment li facilities which causes them to become inoperable, or substantial and permanent loss of natural resources which can reasonably be expected to occur in the absence of a bypass. Severe property damage does not mean economic loss caused by delays in production. 13. Upset: An exceptional incident in which there is unintentional and temporary noncompliance with technology-based permit effluent limitations because of factors beyond the reasonable control of the permittee. An upset does not include noncompliance to the extent caused by operational error, improperly designed treatment facilities, inadequate treatment facilities, lack of preventive maintenance, or careless or improper operation. SECTION B. GENERAL CONDITIONS 1. Duty to Comply The permittee must comply with all conditions of this General Permit. Any permit noncompliance constitutes a violation of the Clean Water Act and is grounds for enforcement action; for permit termination, revocation and reissuance, or modification; or denial of a permit upon renewal application. a. The permittee shall comply with standards or prohibitions established under section 307(a) of the Clean Water Act for toxic pollutants within the time provided in the regulations that establish these standards or prohibitions, even if the permit has not yet been modified to incorporate the requirement. b. The Clean Water Act provides that any person who violates a permit condition is subject to a civil penalty not to exceed $25,000 per day for each violation. Any person who negligently violates any permit condition is subject to criminal penalties of $2,500 to $25,000 per day of violation, or imprisonment for not more than 1 year, or both. Any person who knowinglyf violates any permit conditions is subject to criminal penalties of$5,000 to $50,000 per day of violation, or imprisonment for not more than 3 years, or both. Also, any person who violates a permit condition may be assessed an administrative penalty not to exceed$10,000 per violation with the maximum amount not to exceed $125,000. [Ref: Section 309 of the Federal Act 33 USC 1319 and 40 CFR 122.41(a).] c. Under state law, a daily civil penalty of not more than twenty-five thousand dollars ($25,000) per violation may be assessed against any person who violates or fails to act in accordance with the terms, conditions, or requirements of a permit. [Ref: North Carolina General Statutes 143- 215.6A] d. Any person may be assessed an administrative penalty by the Director for violating section 301, 302, 306, 307, 308, 318, or 405 of the Act, or any permit condition or limitation implementing any of such sections in a permit issued under section 402 of the Act. Administrative penalties for Class I violations are not to exceed $11,000 per violation, with the maximum amount of any Class I penalty assessed not to exceed $27,500. Penalties for Class II violations are not to exceed $11,000 per day for each day during which the violation continues, with the maximum amount of any Class II penalty not to exceed $137,500. 2. Duty to Mitigate The permittee shall take all reasonable steps to minimize or prevent any discharge in violation of this permit. 3. Civil and Criminal Liability Except as provided in permit conditions on "Bypassing" (Part II, CA.) and "Power Failures" (Part II, C.1), nothing in this permit shall be construed to relieve the permittee from any responsibilities, liabilities, or penalties for noncompliance pursuant to NCGS 143-215.3, 143-215.6 or Section 309 of the Federal Act, 33 USC 1319. Furthermore, the permittee is responsible for consequential damages, such as fish kills, even though the responsibility for effective compliance may be temporarily suspended. 4. Oil and Hazardous Substance Liability Page 4 of 11 Pages � n General Permit NCG550000 Nothing in this permit shall be construed to preclude the institution of any legal action or relieve the permittee from any responsibilities, liabilities, or penalties to which the permittee is or may be subject to under NCGS 143-215.75 at seq. or Section 311 of the Federal Act, 33 USG 1321. Furthermore, the permittee is responsible for consequential damages, such as fish kills, even though the responsibility for effective compliance may be temporarily suspended. 5. Property Rights The issuance of this permit does not convey any property rights in either real or personal property, or any exclusive privileges, nor does it authorize any injury to private property or any invasion of personal rights, nor any infringement of Federal, State or local laws or regulations. 6. Onshore or Offshore Construction This permit does not authorize or approve the construction of any onshore or offshore physical structures or Facilities or the undertaking of any work in any navigable waters. 7. Severability The provisions of this permit are severable, and if any provision of this permit, or the application of any provision of this permit to any circumstances,is held invalid, the application of such provision to other circumstances, and the remainder of this permit, shall not be affected thereby. 8. Duty to Provide Information The permittee shall furnish to the Permit Issuing Authority, within a reasonable time, any information which the Permit Issuing Authority may request to determine whether cause exists for modifying, revoking and reissuing, or terminating this permit or to determine compliance with this permit. The permittee shall also furnish to the Permit Issuing Authority upon request, copies of records required to be kept by this permit. 9. Duty to Reapply If the permittee wishes to continue an activity regulated by this permit after the expiration date of this permit, the permittee must apply for and obtain a new permit. 10. Permit Termination After public notice and opportunity for a hearing, the General Permit and Certificates of Coverage issued under this General Permit may be terminated for cause. 11,When an Individual Permit may be Required The Division may require any owner authorized to discharge under this permit to apply for and obtain an individual permit. Cases where an individual permit may be required include, but are not limited to, the following; a. The discharger is a significant contributor of pollution. b. Conditions at the operating facility change altering the constituents and/or characteristics of the discharge such that the discharge no longer qualifies for a General Permit. c. The discharge violates the terms or conditions of this permit. d. A change has occurred in the availability of demonstrated technology or practices for the control or abatement of pollutants applicable to the point source. e. Effluent limitation guidelines are promulgated for the point sources covered by this permit. I. A water quality management plan containing requirements applicable to such point sources is approved after the issuance of this permit. This permit may be terminated as to an individual owner for any of the reasons set forth above after appropriate notice in accordance with N.O.G.S, 143-215.1. 12.When an Individual Permit may be Requested Any permittee operating under this permit may request to be excluded from coverage by applying for an individual permit. When an individual permit is issued, the applicability of this General Permit is automatically terminated on the effective date of the individual permit. 13. Signatory Requirements All applications, reports, or information submitted to the Permit Issuing Authority shall be signed and certified. Page 5 of 11 Pages General Permit NCG550000 a. All permit applications shall be signed as follows: (1) In the case of a corporation, by a principal executive officer of at least the level of vice president, or his duly authorized representative, if such representative is responsible for the overall operation of the facility from which the discharge described in the permit application form originates;(2)In the case of a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or; (3) In the case of a municipality, State, Found, or other public entity by either a principal executive officer, ranking elected official, or other duly authorized employee. b. All reports required by the permit and other information requested by the Permit Issuing Authority shall be signed by a person described above or by a duly authorized representative of that person, A person is a duly authorized representative only if: (1) The authorization is made in writing by a person described above; (2) The authorization specified either an individual or a position having responsibility for the overall operation of the regulated facility or activity, such as the position of plant manager, operator of a well or well field, superintendent, a position of equivalent responsibility, or an individual or position having overall responsibility for environmental matters for the company. (A duly authorized representative may thus be either a named individual or any individual occupying a named position.); and (3) The written authorization is submitted to the Permit Issuing Authority. c. Certification: Any person signing a document under paragraphs a. or b. of this section shall make the following certification: "I certify,under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 14.Permit Actions This permit may be modified, revoked and reissued, or terminated for cause. The filing of a request by the permittee for a permit modification, revocation and reissuance, or termination, or a notification of planned changes or anticipated noncompliance does not stay any permit condition. 15. Permit Modification Revocation and Reismance. or Termination The issuance of this permit does not prohibit the permit issuing authority from reopening and modifying the permit, revoking and reissuing the permit, or terminating the permit as allowed by the laws, rules, and regulations contained in Title 40, Code of Federal Regulations, Parts 122 and 123; Title 15A of the North Carolina Administrative Code, Subchapter 2H .0100; and North Carolina General Statute 143-215.1 at. al. SECTION C. OPERATION AND MAINTENANCE OF POLLUTION CONTROLS 1. Certified Operator Pursuant to Chapter 90A-44 of North Carolina General Statutes, the permittee shall employ a certified wastewater treatment plant operator in responsible charge (ORC) of the wastewater treatment facilities. Such operator must hold a certification of the grade equivalent to or greater than the classification assigned to the wastewater treatment facilities. The permittee shall notify the Division's Operator Training and Certification Unit within one hundred and twenty days of any change in the ORC status. NOTE. This requirement does not apply until the permittee receives a letter notifying them of classification of the facility. Currently,facilities are not being classified for this purpose, but may at some time in the future. Page 6 0£11 Pages General Permit NCG550000 2. Proper Operation and Maintenance The permittee shall at all times properly operate and maintain all facilities and systems of treatment and control (and related appurtenances) which are installed or used by the permittee to achieve compliance with the conditions of this permit. Proper operation and maintenance also includes adequate laboratory controls and appropriate quality assurance procedures. This provision requires the operation of back-up or auxiliary facilities [or similar systems] installed by a permittee only when the operation is necessary to achieve compliance with the conditions of the permit. 3. Need to Halt or Reduce not a Defense It shall not be a defense for a permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity in order to maintain compliance with the conditions of this permit. 4. Bvnassing of Treatment Facilities a. Bypass not exceeding limitations. The permittee may allow any bypass to occur which does not cause effluent limitations to be exceeded, but only if it also is for essential maintenance to assure efficient operation. These bypasses are not subject to the provisions of Paragraphs b. and c, of this section. b. Notice (1) Anticipated bypass. If the permittee knows in advance of the need for a bypass, it shall submit prior notice, if possible at least ten days before the date of the bypass; including an evaluation of the anticipated quality and affect of the bypass. (2) Unanticipated bypass. The permittee shall submit notice of an unanticipated bypass as required in Part JI.E.6 of this permit. (24-hour notice). c. Prohibition of Bypass (1) Bypass is prohibited and the Permit Issuing Authority may take enforcement action against a permittee for bypass, unless: (a) Bypass was unavoidable to prevent loss of life, personal injury or severe property damage; (b) There were no feasible alternatives to the bypass, such as the use of auxiliary treatment facilities, retention of untreated wastes or maintenance during normal periods of equipment downtime. This condition is not satisfied if adequate backup equipment should have been installed in the exercise of reasonable engineering judgment to prevent a bypass which occurred during normal periods of equipment downtime or preventive maintenance; and (c) The permittee submitted notices as required under Paragraph b. of this section. (2) The Permit Issuing Authority may approve an anticipated bypass, after considering its adverse affects, if the Permit Issuing Authority determines that it will meet the three conditions listed above in Paragraph c. (1) of this section. 5. Upsets a. Effect of an upset. An upset constitutes an affirmative defense to an action brought for noncompliance with such technology based permit effluent limitations if the requirements of paragraph b. of this condition are met. No determination made during administrative review of claims that noncompliance was caused by upset, and before an action for noncompliance, is final administrative action subject to judicial review. b. Conditions necessary for a demonstration of upset. A permittee who wishes to establish the affirmative defense of upset shall demonstrate, through properly signed, contemporaneous operating logs, or other relevant evidence that: Page 7 of 11 Pages 7 / General Permit NCG550000 (1) An upset occurred and that the permittee can identify the cause(s) of the upset; (2) The permitted facility was at the time being properly operated; and (3) The permittee submitted notice of the upset as required in Part II.E.6.b.2 of this permit. (3) The permittee complied with any remedial measures required under Part II.B.2 of this permit. c. Burden of proof. In any enforcement proceeding the permittee seeking to establish the occurrence of an upset has the burden of proof. 6. Removed Substances Solids, sludges, filter backwash, or other pollutants removed in the course of treatment or control of wastewaters shall be disposed of in accordance with NCGS 143-215.1 and in a manner such as to prevent any pollutant from such materials from entering waters of the State or navigable waters of the United States. The permittee shall comply with all existing federal regulations governing the disposal of sewage sludge. Upon promulgation of 40 CFR Part 503, any permit issued by the Permit Issuing Authority for the disposal of sludge may be reopened and modified, or revoked and reissued, to incorporate applicable requirements at 40 CFR Part 503. The permittee shall comply with applicable 40 CFR Part 503 Standards for the Use and Disposal of Sewage Sludge (when promulgated) within the time provided in the regulation, even if the permit is not modified to incorporate the requirement. The permittee shall notify the Permit Issuing Authority of any significant change in its sludge use or disposal practices. 7. Power Failures The permittee is responsible for maintaining adequate safeguards as required by DWQ Regulation, Title 15A, North Carolina Administrative Code, Subchapter 211, .0124 Reliability, to prevent the discharge of untreated or inadequately treated wastes during electrical power failures either by means of alternate power sources, standby generators or retention of inadequately treated effluent. SECTION D. MONITORING AND RECORDS 1. Representative Sampling Samples collected and measurements taken, as required herein, shall be characteristic of the volume and nature of the permitted discharge. Samples collected at a frequency less than daily shall be collected on a day and time that is characteristic of the discharge over the period the sample represents. All samples shall be taken at the monitoring points specified in this permit and, unless otherwise specified, before the effluent joins or is diluted by any other wastestream, body of water, or substance. Monitoring points shall not be changed without notification to and the approval of the Permit Issuing Authority. 2. Test Procedures Test procedures for the analysis of pollutants shall conform to the EMC regulations published pursuant to NCGS 143-215.63 et. seq., the Water and Air Quality Reporting Acts, and to regulations published pursuant to Section 304(g), 33 USC 1314, of the Federal Water Pollution Control Act, as Amended, and Regulation 40 CFR 136. To meet the intent of the monitoring required by this permit, all test procedures must produce minimum detection and reporting levels that are below the permit discharge requirements and all data generated must be reported down to the minimum detection or lower reporting level of the procedure. If no approved methods are determined capable of achieving minimum detection and reporting levels below permit discharge requirements, then the most sensitive (method with the lowest possible detection and reporting level) approved method must be used. 3. Penalties for Tampering The Clean Water Act provides that any person who falsifies, tampers with, or knowingly renders inaccurate, any monitoring device or method required to be maintained under this permit shall, upon conviction, be punished by a fine of not more than $10,000 per violation, or by imprisonment for not more than two years per violation, or by both. In the case of a second or subsequent conviction, punishment is a fine of not more than$20,000 per day of violation, or by imprisonment of not more than 4 years, or both. Page 8 of 11 Pages General Permit NCGSS0000 4. Records Retention The permittee shall retain records of all monitoring information, including all calibration and maintenance records and all original strip chart recordings for continuous monitoring instrumentation, copies of all reports required by this permit, for a period of at least 3 years from the date of the sample, measurement, report or application. This period may be extended by request of the Director at any time. 5. Recording Results For each measurement or sample taken pursuant to the requirements of this permit, the permittee shall record the Following information: a. The date, exact place, and time of sampling or measurements; b. The individual(s) who performed the sampling or measurements; c. The date(s) analyses were performed; d. The individual(s) who performed the analyses; e. The analytical techniques or methods used; and f. The results of such analyses. 6. Inspection and Entry The permittee shall allow the Director or his authorized representative[s], upon the presentation of credentials and other documents as may be required by law, to; a. Enter upon the permittee's premises where a regulated facility or activity is located or conducted, or where records must be kept under the conditions of this permit; b. Have access to and copy any records that must be kept under the conditions of this permit; c. Inspect any facilities, equipment (including monitoring and control equipment), practices, or operations regulated or required under this permit; and d. Sample or monitor, for the purposes of assuring permit compliance or as otherwise authorized by the Clean Water Act,any substances or parameters at any location. SECTION E. REPORTING REOUIREMENTS 1. Submission of Reports Submission of standardized monitoring forms or other monitoring reports to the Division is not required. All monitoring information and copies of any reports required by this permit, must be retained on site for a period of at least 3 years from the date of the sample, measurement, report or application. This period may be extended by request of the Director at any time, The permittee shall furnish to the Permit Issuing Authority upon request, copies of records required to be kept by this permit. 2. Change in Discharge All discharges authorized herein shall be consistent with the terms and conditions of this permit. The discharge of any pollutant identified in this permit more frequently than or at a level in excess of that authorized shall constitute a violation of the permit. 3. Planned Changes The permittee shall give notice to the Director as soon as possible of any planned physical alterations or additions to the permitted facility. Notice is required only when: a. The alteration or addition to a permitted facility may meet one of the criteria for determining whether a facility is a new source in 40 CFR Part 122.29 (b); or b. The alteration or addition could significantly change the nature or increase the quantity of pollutants discharged. This notification applies to pollutants that are not subject to effluent limitations in the permit or to notification requirements under 40 CFR Part 122.42 (a) (1). 4. Anticipated Noncompliance The permittee shall give advance notice to the Director of any planned changes in the permitted facility or activity that may result in noncompliance with permit requirements. 5. Transfers Page 9 0£I I Pages General Permit NCG550000 This permit is not transferable to any person except after notice to and approval by the Director. III The Director may require modification or revocation and reissuance of the permit and incorporating such other requirements as may be necessary under the Clean Water Act. 6. Duty to Report Noncompliance a. The permittee shall report to the central office or the appropriate regional office any noncompliance that may endanger health or the environment. Any information shall be provided orally within 24 hours from the time the permittee became aware of the circumstances. A written submission shall also be provided within 5 days of the time the permittee becomes aware of the circumstances. (1) The written submission shall contain a description of the noncompliance, and its cause; the period of noncompliance, including exact dates and times, and if the noncompliance has not been corrected, the anticipated time it is expected to continue; and steps taken or �. planned to reduce, eliminate, and prevent reoccurrence of the noncompliance. b. The following shall be included as information that must be reported within 24 hours under this paragraph. (1) Any unanticipated bypass that exceeds any effluent limitation in the permit. (2) Any upset which exceeds any effluent limitation in the permit. (3) Violation of a maximum daily or monthly average discharge limitation for any of the pollutants listed by the Director in the permit to be reported within 24 hours. c. The Director may waive the written report on a case-by-case basis for reports under paragraph b. above of this condition if the oral report has been received within 24 hours. 7. Other Information Where the permittee becomes aware that it failed to submit any relevant facts in a permit application, or submitted incorrect information in a permit application or in any report to the Director, it shall promptly submit the correct facts or information. S. Noncompliance Notification Procedure The permittee shall report by telephone to either the central office or the appropriate regional office of the Division as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of any of the following: a. Any occurrence at the water pollution control facility which results in the discharge of significant amounts of wastes which are abnormal in quantity or characteristic; such as the dumping of the contents of a sludge digester; the known passage of a slug of hazardous substance through the facility; or any other unusual circumstances. b. Any process unit failure, due to known or unknown reasons, that render the facility incapable of adequate wastewater treatment such as mechanical or electrical failures of pumps, aerators, compressors, etc. c. Any failure of a pumping station, sewer line, or treatment facility resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report (in letter form] within 5 days following first knowledge of the occurrence. 9. Availability of Reports Except for data determined to be confidential under NCGS 143-215.3(a)(2) or Section 308 of the Federal Act, 33 USC 1318, all reports prepared in accordance with the terms shall be made available for public inspection at the offices of DWQ or at the site of the discharge within a reasonable time period, not to exceed five (5) days. As required by the Act, effluent data shall not be considered confidential. Knowingly making any false statement on any such report may result in the imposition of criminal penalties as provided for in NCGS 143-215.1(b)(2) or in Section 309 of the Federal Act. 10. Penalties for Falsification of Reports Page 10 of 11 Pages General Permit NCG550000 The Clean Water Act provides that any person who knowingly makes any false statement, representation, or certification in any record or other document submitted or required to be maintained under this permit, including monitoring reports or reports of compliance or noncompliance shall, upon conviction, be punished by a fine of not more than $10,000 per violation, or by imprisonment for not more than two years per violation, or by bath. PART III OTHER REQUIREMENTS 1. Previous Permits All previous State water quality permits issued to this facility for this particular discharge, whether for construction or operation or discharge, are hereby revoked by issuance of this permit and subsequent issuance of a Certificate of Coverage. The conditions, requirements, terms, and provisions of this permit authorizing discharge under the National Pollutant Discharge Elimination System govern discharges from this facility. 2. Construction No construction of wastewater treatment facilities or additions thereto shall be begun until Final Plans and Specifications have been submitted to and approved by the Division. Design and operation of facilities and/or treatment works shall be in accordance with the application and supporting information. If facility deficiencies, design and/or operational, are identified in the future which could affect the facility performance or reliability, it is the responsibility of the permittee to correct such deficiencies. 3. Limitations Reouener This permit shall be modified or alternatively, revoked and reissued, to comply with any applicable effluent guideline or water quality standard issued or approved under Sections 302(b) (2) (c), and (d), 304(b) (2), and 307(a) (2) of the Clean Water Act, if the effluent guideline or water quality standard so issued or approved: a. contains different conditions or is otherwise more stringent than any effluent limitation in the permit; or b, controls any pollutant not limited in the permit. The permit as modified or reissued under this paragraph shall also contain any other requirements in the Act then applicable. PART IV ANNUAL ADMINISTERING&COMPLIANCE MONITORING FEE The permittee must pay the annual administering and compliance monitoring fee (if any such fee is assessed) within 30 days after being billed by the Division. Failure to pay such fees in a timely manner in accordance with 15 NCAC 211.0105(b)(4) may cause the Division to initiate action to revoke the Certificate of Coverage. Page I of 11 Pages NCDENR 1 North Carolina Department of Environment and!Na l Re6l 2007 Division of Water Quality I Michael F.Easley, Governor -,,ROss,JimSecretary{ AsfAtan W Klitrick F 2f FDireGtod January 9, 2007 Victor Babaoff 308 Secretariat Ln Fairview, NC 28730 Subject: Renewal Notice/General Permit NCG550000 Certificate of Coverage NCG550475 Buncombe County Dear Permittee: You are receiving this notice because you currently own a property covered under the subject General Permit for the discharge of domestic wastewater. NCG550000 will expire on July 31, 2007. Federal (40 CFR 122.41) and North Carolina(15A NCAC 2H.0105(e))regulations require that permit renewal applications be filed at least 180 days prior to expiration of the current permit. To satisfy this requirement, the Division must receive a renewal request postmarked no later than February 1, 2007. The Certificate of Coverage(CoC) specific to your property was last issued on August 1, 2002. The Division needs information from you to determine if coverage under NCG550000 is still necessary. ➢ If your property still has a wastewater system like the ones described in the enclosed Technical Bulletin, you must renew the subject CoC. Complete the enclosed form and submit it to the address on the form. ➢ If you are not sure what type of system your property has, contact Larry Frost in the NC DENR Asheville Regional Office at. That person [or other staff members] can help you determine if you should renew your CoC, ➢ If you know that your property no longer discharges wastewater, contact me at the address or phone number listed below to request rescission of the CoC. ➢ This information request does not pertain to the Annual Fee of$50.00 billed separately by the Division's Budget Office. No money is required for this procedure. The Annual Fee is like the fee you annually pay the DMV for the sticker on your vehicle's license plate. Renewal of your CoC is like the renewal of your Driver's License [ca. every five years]. ➢ If you have already mailed a renewal request, you may disregard this notice. 1617 Mail Service Center,Raleigh,North Carolina 27699-1617 512 Noah Salisbury Street,Raleigh,Noah Carolina 27604 �n0� hiCarolina Phone: 919 733-5083,extension 511/FAX 919 733-0719/charles.weaver@ncmail.net A '/ / An Equal Opportunity/Affirmative Action Employer—50%Recyclec/10%Post Consumer Paper ;V�tuNal`# NCG550475 renewal notice 7 7 January 9,2007 The attached application form shows the information the Division has on file for your property. Please verify that the provided information is correct, or make corrections on the form. Complete the additional questions, then sign and date the form. The completed form should be submitted to the address listed below the signature block. If you have any questions concerning this matter, please contact me at the telephone number or e-mail address listed below. (If it is difficult to reach me, please be aware that your facility is one of over 1100 that I am contacting regarding the renewal of NCG550000.) Thanks for your attention to this matter. Sincerely, Charles H. Weaver,Jr. �- NPDES Unit cc: Central Files Asheville Regional Office/Larry Frost NPDES file State of North Carol `l, Department of r „flent and Natural Resources r Division of Water Quality a Michael F. Easley, Governor NCDENR William G. Ross Jr., Secretary Alan W. Klimek, P.E., Director NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES July 26,2002 VICTOR BABAOFF BABAOFF VICTOR-RESIDENCE 308 SECRETARIAT LN FAIRVIEW, NC 28730 Subject: Reissue-NPDES Wastewater Discharge Permit Babaoff Victor-Residence COC Number NCG550475 Buncombe County Dear Formation: In response to your renewal application for continued coverage under general permit NCG550000,the Division of Water Quality(DWQ)is Forwarding herewith the reissued wastewater general permit Certificate of Coverage (COC). This COC is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S.Environmental Protection Agency, dated May 9, 1994(or as subsquently amended). The following information is included with your permit package: * A copy of the Certificate of Coverage for your treatment facility * A copy of General Wastewater Discharge Permit NCG550009 * A copy of a Technical Bulletin for General Wastewater Discharge Permit NCG550000 Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal,state,or local law rule,standard,ordinance,order,judgment,or decree. Please note that effective January 1, 1999 the fees for all permits issued by DWQ were changed. This changed the fee for your wastewater general permit coverage from a$240 fee paid once every five years to a yearly fee of$50. If you have not already been billed this year for the yearly fee,you will receive a bill later this year. If you have any questions regarding this permit package please contact Mack Wiggins of the Central Office Stormwater and General Permits Unit at(919)733-5083,ext.542 Sincerely, for Alan W.Klimek,P.E. cc: Central Files Stormwater&General Permits Unit Files Asheville Regional Office 1617 Mail Service Center, Raleigh,North Carolina 27699-1617 Telephone 919.733-5083 FAX 919-733-0719 An Equal Opportunity Affirmative Action Employer 50 h recycled/10%post-consumer paper -•State of North �. xr. �ria` - ,. - ` Department ofR` i nment, Health and Natural Resources f ` Division of Environmental Management James B. Hunt, Jr., Governor ��� Jonathan B. Howes, Secretary ID C A , A. Preston Howard, Jr.,, P.E., Director , V November 29, 1993 - Victor Babaoff 308 Secretariat Lane Fairview NC 28730 Subject: Certified Operator Requirements Single Family Treatment Systems NPDES Permit No.NCG550475 Buncombe County Dear Mr.Babaoff: During February of this year,public hearings were held on proposed changes to modify the operator certification rules. The proposed rules included a requirement that single-family discharge systems would be classified wastewater treatment facilities,which would require an annual inspection by a certified operator. The intent of the rule was to insure that the systems are being properly operated and maintained. During the public comment period, a significant amount of comments, statements and additional information was submitted. As a result, the Water Pollution Control System Operators Certification Commission amended the proposed rules. The rule, as adopted and effective July 1, 1993, now requires single-family discharging systems to be classified only if they are permitted after July I, 1993 or if upon inspection by the Division of Environmental Management (DENT) it is found that the system is not being adequately operated and maintained. Systems can be inspected by DEM during routine compliance inspections, permit renewals, or complaint investigations. Once a system is classified, it will be required to have at a minimum, an annual inspection by a certified operator. It is important to remember that the NPDES permit is part of a Federal program administered by the State of North Carolina and that violations of the permit are enforceable by Federal and State laws. Although your system will not be required to have a certified operator at this time,proper operation and maintenance is needed for the system to function satisfactorily. In as much as each system must be individually designed and sited, special maintenance requirements may apply to a specific installation. The attached maintenance schedule should however be applicable to most systems. The frequencies suggested are considered to be the minimum necessary. More frequent attention may be needed for a specific system and may be required by conditions of the permit. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-0026 FAX 919-733-1338 An Equal Opportunity Affirmative Action Employer 50%recycled/10% post-consumer paper Certified Operator Requirements NCG550475 Page 2 In addition to being required by your permit,proper maintenance of your treatment system �� is extremely important to the long term serviceability of your wastewater treatment system. If proper maintenance is not given to the system, it will fail and will result in major expenses for repairs. We would strongly encourage you to take the nemssary action to insure that your system is operating properly. If we can be of any assistance to you or if you have any questions or comments,please call Dwight Lancaster of our staff at(919)733-0026. erely, Cindy inan, pervi or ga, ca 'on Unit cc:Asheville Regional Office-Water Quality Facilities Assessment Unit Central Files - (- i i IIG "State of North Carolina,) 8` Department of Environnient, Health and Natural Resources Division of Environmental Management a James B. Hunt, Jr., Governor r��� L Jonathan B. Howes, Secretary ID FEE N F1 A. Freston Howard, Jr., R.E., Director September 30,1993 VICTOR BABAOFF BABAOFF (RESIDENCE), VICTOR 308 SECRETARIAT LANE 7 O FAIRVIEW NC 28730 Subject BABAOFF (RESIDENCE), VICTOR Certificate of Coverage NCG550475 General Permit NCG550000 Formerly NPDES Permit NCO074098 C/' Buncombe County � Dear Permittee: �J The Division of Environmental Management has recently evaluated all existing individual permits for potential coverage under general permits currently issued by the Division.. 15A N.C.A.C. 211.0127 allows the Division to evaluate groups of permits having similar discharge activities for coverage under general permits and issue coverage where the Division finds control of the discharges more appropriate in this manner.The Division has determined that the subject discharge qualifies for such coverage. Therefore,the Division is hereby issuing the subject Certificate of Coverage under the state-NPDES general permit no. NCG550000 which shall void NPDES Permit NC0074098. This Certificate of Coverage is issued pursuant to the requirements of North Carolina and the US Environmental Protection Agency Memorandum of Agreement dated December 6,1983 and as subsequently amended. If any parts,measurement frequencies or sampling requirements contained in this general permit are unacceptable to you,you have the right to submit an individual permit application,associated processing fee and letter requesting coverage under an individual permit. Unless such demand is made,this decision shall be final and binding. Please take notice this Certificate of Coverage is not transferable. Part II,Ek addresses the requirements to be followed in case of change of ownership or control of this discharge. In the event that the facilities fail to perform satisfactorily,including the creation of nuisance conditions,the Pemuttee shall take immediate corrective action,including those as may be required by this Division, such as the construction of additional or replacement wastewater treatment or disposal facilities. Construction of any wastewater treatment facilities.will require issuance of an Authorization to Construct from this Division. Failure to abide by the requirements contained in this Certificate of Coverage and respective general permit may subject the Permittee to an enforcement action by the Division of Environmental Management in accordance with North Carolina General Statute 143-215.6A to 143-215.6C. Please note that the general permit does require monitoring in accordance with federal law. The monitoring data is not required to be submitted to the Division unless specifically requested,however,the permittee is required to maintain all records for a period of at least three (3) years. Post Office Box 29535,Raleigh,North Carolina 27626-0535 Telephone(919)733-5083 FAX(919)733-9919 An Equal Opportunity Affirmative Action Employer 50%recycled-10%post-consumer paper Page 2 VICTOR BABAOFF BABAOFF (RESIDENCE), VICTOR Certificate of Coverage No. NCG550475 The issuance of this Certificate of Coverage Is an administrative action initiated by the Division of Environmental Management and therefore,no fees are due at this time. In accordance with current rules,there are no annual administrative and compliance monitoring fees for coverage under general permits. The only fee you will be responsible for is a renewal fee at the time of renewal. The current permit expires July 31,1997. This coverage will remain valid through the duration of the attached general permit. The Division will be responsible for the reissuance of the general permit and at such time,you will be notified of the procedures to follow to continue coverage under the reissued permit. Unless you fail to follow the procedures for continued coverage,you will continue to be permitted to discharge in accordance with the attached general permit Ip The issuance of this Certificate of Coverage does not preclude the Permittee from complying with any and all statutes,rules,regulations,or ordinances which may be required by the Division of Environmental Management or permits required by the Division of Land Resources,the Coastal Area Management Act or any Federal or Local other governmental permit that may be required. If you have any questions or need additional information regarding this matter,please contact either the Asheville Regional Office,Water Quality Section at telephone number 704/251-6208,or a review engineer in the NPDES Group in the Central Office at telephone number 919/733-5083. i �A.Preston Howar .,P.E. cc: Asheville Regional Office Central Files it STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO. NCG550000 CERTIFICATE OF COVERAGE No.NCG550475 TO DISCHARGE TREATED DOMESTIC WASTEWATERS FROM SINGLE FAMILY RESIDENCES AND SIMILIAR WASTEWATERS UNDER THE NATIONAL POLLUNTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1,other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission,and the Federal Water Pollution Control Act,as amended, BABAOFF (RESIDENCE), VICTOR is hereby authorized to discharge treated domestic wastewater from a facility located at BABAOFF (RESIDENCE), VICTOR Buncombe County to receiving waters designated as the REED CREEK/FRENCH BROAD RIVER BASIN in accordance with the effluent limitations,monitoring requirements,and other conditions set forth in Parts L IL III and IV of General Permit No. NCG550000 as attached. This certificate of coverage shall become effective November 1, 1993. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day, September 30,1993. A.Preston Howar ,Jr.,P.E.,Director Division of Environmental Management By Authority of the Environmental Management Commission q i 5 ! Ila State of North Carolina Department of Environment, 4 • Health and Natural Resources Division of Environmental Management ' �_ Aic ames B. Hunt, Jr., Governor �E H N Fl nathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director July 15, 1993 Victor Babaoff 308 Secretariat Lane Fairview,NC 28730 Subject: Permit No. NCO074098 Babaoff Residence Buncombe County Dear Mr.Babaoff: - In accordance with your application for discharge permit received on March 11, 1993,we are forwarding herewith the subject state - NPDES permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, Post Office Drawer 27447, Raleigh, North Carolina 27611 -7447. Unless such demand is made,this decision shall be final and binding. Please take notice this permit is not transferable. Part II, B.2. addresses the requirements to be followed in case of change in ownership or control of this discharge. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Mr. Mack Wiggins at telephone number 91033-5083. Sincerely, Original Signed By Coleen H. Sullins A. Preston Howard,Jr Director cc: Mr. Jim Patrick,EPA Asheville Regional Office P.O.Box 29535,Raleigh,North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50%recycled/10%post-consumer paper Wit i . p1m, - NCO074098 STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH,AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT PERMIT TO DISCHARGE WASTEWATER UNDER THE NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision.of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission,and the Federal Water Pollution Control Act,as amended, Victor Babaoff is hereby authorized to discharge wastewater from a facility located at Babaoff Residence on NC Highway 74,adjacent to Secretariat Lane Fairview Downs,Northwest of Fairview Buncombe County to receiving waters designated as Reed Creek in the French Broad River Basin in accordance with effluent limitations,monitoring requirements,and other conditions set forth in Parts L II, and III hereof. This permit shall become effective August 1, 1993 i. 1 This permit and the authorization to discharge shall expire at midnight on September 30, 1995 Signed this day July 15, 1993 Original Signed By Coleen H. Sullins A. Preston Howard, Jr., P,E., Director Division of Environmental Management By Authority of the Environmental Management Commission Permit No. NC0074098 SUPPLEMENT TO PERMIT COVER SHEET Victor Babaoff is hereby authorized to: 1. Continue to operate an existing wastewater treatment system consisting of a septic tank, sandfilter,chlorination and cascade aeration located at Babaoff Residence,on NC Highway 74, adjacent to Secretariat Lane, Fairview Downs,Northwest of Fairview,Buncombe County (See Part III of this Permit), and 2. Discharge.from said treatment works at the location specified on the attached map into Reed Creek which is classified Class WS-BI-Trout waters in the French Broad River Basin.. e \ p Q1 f otter . o C I�J� ' p 9 y y Ar AN "� 1p� V l c ^' V �pj,' J•,.&&6[!^ �^{tC �,`)\ / hz cn ( C ' liI+✓ i � ARW ` aK tiCh�i i h rta1'L+�{ tl 8M � t sy n' ��� � ✓) \ I 1 � pro?� t 4,.1•��r a � � J r yi ^� F ��a{ idYrFer ° xssry`�ryr,rrr� F § ( , tr E E ' { 7 § ) !; k : z -6 / ƒ � a . ° = ! ) ] J ; } § ! - FART 1 ICI "Act" used herein means the Federal Water pollution Control Act, As Amended. "DEM" used herein means the Division of $nvIrommental Management of the Department of Natural Resources and Community Development. "EmV used herein means the North Carolina 6wiromsnta2 Management I_ Commission. Definitions a.. The monthly average, other than for fecal coliform bacteria, is the arithmetic mean of all the composite samples collected in a one-month period. The monthly average for fecal coliform bacteria Is the geometric mean of samples collected in a one-month period. b. The weekly average, other than for fecal coliform bacteria, is the arithmetic new of all the composite samples collected during a one-week period. The weekly average for fecal coliform bacteria Is the geometric mean of samples collected in a one-week period. c. Flow, .M3/day (MGD): The flow limit expressed in this permit Is the 24-hour average flow, averaged monthly.. It is determined as the arithmetic mean of the total daily flows recorded during the calendar month. d. Arithmetic Mean: The arithmetic mean of any set of values is the . summation of the Individual values divided by the number of indi- vidual values. e. Geometric Mean: The geometric mean of any set of values is the Nth root of the product of the individual values where N is equal to the number of individual values. The geometric mean is equivalent to the "tile& of the arithmetic mean of the logarithms of the indi- vidual values. For purposes of calculating the geometric mean, values of zero (0) shall be considered to be one (1). I, TART I A. NANACCOM REQUIPMENIS 1. Change is Discharge All discharges authorised herein shall be consistent with the terms and conditions of this permit. The discharge of any pollutant Identified in this permit more frequently than or at a level in excess of that authorised shall Constitute a violstion of the permit. Any anticipated facility expansions, production increases, or process modifications which will result in new, different, or Increased discharges of pollutants must be reported by submission of a new NPDES application or, if such changes will not violate the effluent limitations specified in this permit, by notice to the DEN of such changes. Following such notice, the permit may be modified to specify and limit any pollutants not previously limited. 2.. Facilities Operation The permittee shall at all times maintain in good working order and operate as efficiently as possible all treatment or control facili- ties or systems installed or used by the permittee to achieve com- pliance with the terms and conditions of tbis permit. 3. Adverse Impact The permittee shall take all reasonable steps to minimise any adverse impact to navigable waters resulting from noncompliance with any effluent limitations specified in this permit, including such accel- erated or additional monitoring as necessary to determine the nature and impact of the noncomplying discharge. 4. Bypassing Any diversion from or bypass of facilities necessary to maintain com- pliance with the terms and conditions of this permit is prohibited, except (i) where unavoidable to prevent loss of life or severe property damage, or (ii) where excessive storm drainage or runoff would damage any facilities necessary for compliance with the effluent limitations and prohibitions of this permit. The permittee shall promptly notify the Water Quality Section of DEN in writing of each such diversion or bypass. 5. . Removed Substances Solids, sludges, filter backwash, or other pollutants removed in the course of treatment or control of wastewaters shall be disposed of in - a manner such as to prevent any pollutant from such material from entering waters of the State or navigable waters of the United States. PART 11 6. Power Failures maintain2a order to prohibitions ofthis permit. the permittea effluent tions and shalleitherc a. Provide an alternative power source sufficient to operate the wastewater control facilities; or, if such alternative paver source is not in existence, b. Halt, reduce, or otherwise control production and/or all dis- charges from wastewater control facilities upon the reduction. loss, or failure of the primary source of power to said waste- water control facilities. B. RESPONSIBILITIES 1. Right of Entry The permittee shall allow the Director of the Division of Environ- mental Managanents the Regional Administrator, and/or their author- ised- representatives, upon the presentations of credentials: a. To enter upon the pernittee's premises where an effluent �. source is located or in which any records are required to be kept under the terms and conditions of this permit; and b. At reasonable times to have access to and copy any records required to be kept under the terms and conditions ofrthis permit; to inspect any monitoring equipment ing method required in this permit; and to sample any discharge of pollutants. 2. Transfer of Ownership or Control This permit is not transferable. In the event of any change in con- trol or ownership of facilities from which the authorised discharge emanates or is contemplated, the pernittee shall notify the prospec- tive owner or controller by letter of the existence of this permit and of the need to obtain a permit in the name of the prospective owner. A copy of the letter shall be forwarded to the Division of Environmental Management. 3. Permit Modification After notice and opportunity for a hearing pursuant to NCCS 143-215.1 (b)(2) and NCCS 143-215.1(e) respectively, this permit may be modi- fied, suspended, or revoked in whole or in part during its term for cause including, but not limited to, the following: 1 J PART II a. Violation of any terms or conditions of this permit; b. Obtaining this permit by misrepresentation or failure to disclose fully all relevant facts; or c. A change In any condition that requires either a temporary or permanent reduction or elimination of the authorised discharge. A. Civil and Criminal Liability Except as provided in permit conditions on "Bypassing" (Part I1. A-4) and "Power Failures (Part II, A-6), nothing in this permit shall be construed to relieve the permittee from civil or criminal penalties for noncompliance pursuant to NCCS 143-215.6 or Section 309 of the Federal Act, 33 OSC 1319. 5. property Bights The issuance of this permit does not convey any property rights in either real or personal property, or any exclusive privileges, nor does it authorize any injury to private property or any invasion of personal rights, nor any infringement of Federal, State, or local lava or regulations. 6. Severability _ The provisions of this permit are severable, and if any provision of this permit, or the application of any provision of this permit to any Circumstance, is held invalid, the application of such provision to other circumstances, and the remainder of this permit shall not be affected thereby. 7. Expiration of permit Permittee is not authorized to discharge after the expiration date. In order to receive authorization to discharge beyond the expiration date, the permittee shall submit such information, forms, and fees as are required by the agency authorized to issue permits no later than 180 days prior to the expiration date. Any discharge without a permit after the expiration will subject the permittee to enforce- ment procedures as provided in NCCS 143-215.6 and 33 USC 1251 at seq.. PART III A. PREVIOUs PERMITS All previous State water quality permits issued to this facility. whether for construction or operation, or discharge, are hereby revoked by Issuance of this permit. The conditions, requirements. terms, and provisions of this permit authorizing discharge Under the National Pollutant Discharge Eliminstion System govern discharges free this facility.X. CONSTRUCTION No construction of wastewater treatmentfacilities or additions thereto shall be begun until Pinal Plans.and Specifications have been submitted to the Division of Environmental Management and written approval and Authorization to Construct have been issued. If no objections to Pinal Plans and Specifications have been made by the DEN after 30 days follow- ing receipt of the plans or issuance of this permit, whichever is latter. the plans may be considered approved and construction authorised. C. SPECIAL CONDITIONS 1. The Permittee shall be responsible for the following items regard- ing the maintenance of the treatment system: a. Septic tanks shall be maintained at all times to prevent seepage of savage or effluents to the surface of the ground. b. Septic tanks need routine maintenance and should be checked at least yearly to determine if solids need to be removed or other maintenance performed. c. Contents removed from septic tanks shall be discharged into I an approved sever system, buried or plowed under at an approved location within 24 hours, or otherwise disposed of at a location and in a manner approved by the State or local agency. 2. The permittee shall properly connect to an operational publicly- owned wastewater collection system within ISO days of its availability to the site. D. Disposal Alternatives The Perminee shall continually evaluate all wastewater disposal alternatives and pursue the most environmentally sound alternative of the reasonably cost effective alternatives. If the facility is in substantial non-compliance with the terms and conditions of the NPDES permit or governing rules,regulations,or laws,the permittee shall submit a report in such form and detail as required by the Division evaluating these alternatives and a plan of action within sixty(60)days of notification by the Division. f, A SOC PRIORIT. ROJECT: Yes No x IF YES, SOC BER TO: PERMITS AND ENGINEERING UNIT C�V " WATER QUALITY SECTION ATTENTION: Mack Wiggins DATE: April 28, 1993 NPDES STAFF REPORT AND RECOMMENDATION COUNTY Buncombe PERMIT NUMBER NCO074098 PART I - GENERAL INFORMATION 1. Facility and Address: Babaoff Residence 308 Secretariat Ln. Post Office Box 6069 Asheville, N. C. 28816 2. Date of Investigation: 4-92 3. Report Prepared By: Linda Wiggs 4. . Persons Contacted and Telephone Number: 704-254-9141 5. Directions to Site: At intersection of Highway 74 and NCSR 2776 travel .2 mile BE on Highway 74. Residence is in Fairview Downs development adjacent to Secretariat Lane. 6. Discharge Point(s) , List for all discharge points: Latitude: 350 32 ' 23" Longitude: 820 25' 58" Attach a USGS map extract and indicate treatment facility site and discharge point on map. U.S.G. S. Quad No. U. S.G. S. Quad Nama Otee rtuj 00 VL 7. Site size and expansion area consistent with application? Yes No I£ No, explain: 8. Topography (relationship to flood plain included) : Flat, not in .flood plain. Page 1 - C� i 9. Location of nearest dwelling: I 10. Receiving stream or affected surface waters: Reed Creek Trib. I. a. Classification: WS III Trout b. River Basin and Subbasin No. : 04-03-02 C. Describe receiving stream features and pertinent downstream uses: Wildlife, agriculture, and trib to stream used as industrial water supply (Cane Creek) . Reed Creek receives treated wastewater from Kasey Residence (NCO070602 ) . PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS I 1 . a. Volume of wastewater to be permitted 0. 000480 MOD (Ultimate Design Capacity) b. What is the current permitted capacity of the Wastewater Treatment facility? Domestic. C. Actual treatment capacity of the current facility (current design capacity 100% d. Date(s) and construction activities allowed by previous Authorizations to Construct issued in the previous two years: e. Please provide a description of existing or substantially constructed wastewater treatment facilities: Existing subsurface sand filter septic tank with chlorination and cascade. f. Please provide a description of proposed wastewater treatment facilities: g. Possible toxic impacts to surface waters: . C1 h. Pretreatment Program (POTWs only) : in development approved should be required not needed I 2. Residuals handling and utilization/disposal scheme: Septic pumping company. a. If residuals are being land applied, please specify DEM Permit Number Residuals Contractor - Telephone Number b. Residuals stabilization: PSRP PFRP OTHER If Page 2 C. Landfill: d. Other disposal/utilization scheme (Specify) : - 3 . Treatment plant classification (attach completed rating sheet) : 4. SIC Codes(s) : 4952 Wastewater Code(s) of actual wastewater, not particular facilities i.e. , non-contact cooling water discharge from a metal plating company would be 14, not 56. Primary 04 Secondary Main Treatment Unit Code: 440-7 - PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved. (municipals only) ? 2. Special monitoring or limitations (including toxicity) requests: 3. Important SOC, JOC, or Compliance Schedule dates: (Please indicate) Date Submission of Plans and Specifications Begin Construction Complete Construction 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non-discharge options available. Please provide regional perspective for each option evaluated. Spray Irrigation: Connection to Regional Sewer System: Subsurface: Other disposal options: 5. Other Special Items: Page 3 PART IV - EVALUATION AND RECOMMENDATIONS ARO recommends Permit Number NCO074098 be reissued. I I' Signa re of epor4 vep er Z �f Wat r Quality Regional Supervisor V Date Page 4 LMAR2w M State of North Carolina WA .NpouauTYSEcnoN Department of Environment, Health, and Natural a ASH EwGENEciON L EEice ces 512 North Salisbury Street • Raleigh, North Carolina 27604 James B. Hunt, Jr., Governor Jonathan R Howes, Secretary March 25, 1993 - vector Babaoff Subject : NPDES Permit Application 308 Secretarial Lane Fairtview, NC 28730 NPDES Permit No.NC0074098 Babaoff Residence Dear Mr. Babaoff Buncombe County This is to acknowledge receipt of the following documents on March 11, 1993: Application Form _ Engineering Proposal (for proposed control facilities.) , Request for permit renewal, '� Application Processing Fee of 5120.00, _ Engineering Economics Alternatives Analysis, _ Local Government Signoff, Source Reduction and Recycling, Lnterbasin Transfer, Other , The items checked below are needed before review can begin: _ Application Form Engineering proposal (see attachment) , _ Application Processing Fee of _ Delegation of Authority (see attached) Biocide Sheet (see attached) _ Engineering Economics Alternatives Analysis, _ Local Government Signoff, — Source Reduction and Recycling, Znterbasin Transfer, — Other RO Bw 27687, Raleigh, Nonh Carolina 276117687 Telephone 919 733 4984 Fax :913733U513 An Egwl Oppol ooe Affirmance Actlon Employer If the application is not made complete within thirty (30) days, it will be returned to you and may be resubmitted when complete. This application has been assigned to Mack Wiggins (919/733-SOB3) of our Permits Unit for review. You wi e a v se o any comments recommendations, questions or other information necessary for the review of the application. I am, by copy of this letter, requesting that our Regional Office Supervisor prepare a staff report and recommendations regarding this discharge . If you have any questions regarding this applications, please contact the review person listed above . Sincerely, C / Co een H. ins, P .E. CC: Asheville Regional Office NORTWµCAROLINA DEPT. OF NADAL RESOURCES AND COMMUNITY DEQPMENT ,,..ENVIRONMENTAL MANAGEMENT COIMISSION NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM Y►LIrAT rmwu APPLICATION"FOR;PERMIT TO DISCHARGE SNORT FORM 0.- ` dro$teMcr s o 7 p ' ""' pII ttcllrtn to be flled'only by ee"icet, wg asale end "iN,_trW, . .. end.ether a.morclal ottablishmts Including vessels - .VW. it. DAr Od not attamgt.to Complete.this love b1thout "Ming the meam9mylng 4tt"ctlbns ►lead, print or Im 1.Now. address, and tolophok number of toC111tY ► olng discsorp ' 1. Street &VMS' -lo 17 . 'C'nrla v.(a L.L) .. C. City. Flzyr� _ S. $fete . . . ... 2. County . i.,,._6 F. 21► 2, 973o S. TolophoM Na. 9v`I 6Ly-4CY2 . . - code 2. SIC ._ (Leave blank) Jp�2. number of eol OYees a. Mature of business d S. (a) Check here 1f dlschirle Occurs e11 y arx or (b) check the'ebnth(s) dtschupa occurs: 1.0Jmuary, 2.a February 5.0111rrb d.o A►ril $.oNsy _ $.o June - 7.00uly S.o Auprtt 1.0 September IO.00ctabor -- 11.0NOrenber 12.0 December (c) Moe P44 days per wet: I.01 2.0 .3 1.04d• 1 $-7,. . ' S. Types of Witte water dlcharged to surface water, 1y (Chick as ea911coble) flow, gallons par writing day - Volume lii argingt(perrcent) c"ratrle doe 0.1-999 1000./999 6 .Sin19 10,000. 50,000 None 0.1- 70• ,S- 05- opentinl do 19,►99 or edra ll,f 61.1 91.9 100 (1) (2) ($) (F) 0) (1) U) (a) m (10) A:._sweturl'. oily erop ' I. tooling Water; etc.. dal ly overage . C. Other dilthir9e(s). daily, Irsragai ' Specify, o. mwmun per operat- _ Ing day for CoRbined' . di tcharge (all types) i 7. if atY N W tYpN of as to trr�fhar11tlwDiu either treated belw ` tnattd, an Mocha 1 q Na f u spit lceale. . Wafa so,000 «mwe ter Nschargea to 0.1•tM IooWM1 .:.1000 fM1 10:oo0af.tM Q1 1E1 :.' Ul A. Nuntciwl uncr systme N. In.,1.lynerri r,•1l L. Septir tank U. Evaporation Page.6 or p,1 .. ._ti . sMcHyz .. - . �. Nrwber stpanto discharge pNntt: 0.0 6 or more !. Mate Of nwlrinp water « wtan .ID. Doti your diiCharge contsln Or is it posllblt for Your discharge to contain ant or eon Of the 10110ming lubstp"A 149fd is "suit of your el Yir.�s. r , Or r,Ocean:rCul. Rickel. S*leetr.. $$InMfhuRa c. pntnels, all MA roalua topper, toed. gI - . na , ono dtorint (nNM+al 1. i' A. yes 1.0 n0 I certify that I am fwiltsr.with the tnfsrutioe cm ne teld 10 the application MI that to the best of g tnalaoga and belief duck Information 1s true, eaoltbe, and accurate. printed hue of Perim Si Ping g� TWO 'Date Applicatim signs - - ignatu n of ICent rah GarolSna General Statute 143-p1S•.6@)(=) Provides thatt Any person report,mP an, y false etptemmt representation, or art cat On In e?t7 ePP e 21 or. other document fiieg tiz required to tag matntatnhat Arrtticla ormwho falslfieekttn�parstwith. viroaneatal Hanagemdat commission lmplgan4lna e or ea or method required to be kawly renders inaccurate r Artialtordtat. re uonitoriti= QtbeEnvIroruntntsl amant 6ocsiesi ,,,tea or maintained under AFS�a1e•1.1;ot• reguiattoaa oL ilia oishableby,& -first iplementing that Aiticles ehsl1'•balt•n-of Y •mtsdeeuanor puniehsbla by-a .sec not to exceed. F .0,tM0, or by Saryrieonmint' r+ot, to exceed six months. or by bbth.: (is lr,S.G. Seete,ael,ev botF., punishment by a fine of"Aot more than $10,000 or ieprieomew?t not nora than 3 y , era similar offense.) . .. OEC 141992 IhhII{{ WATER QUALITY SECTION ASNEVILLE REGIONAL OF ICE December 21, 1992 MICHAEL TAYLOR,AGENT BA13AOFF (RESIDENCE), VICTOR C/O WNC TIRE PO BOX. 6069 ASHEVILLE, NC 28816 Subject: NPDES PERMIT NO. NCO074098 BUNCOMBE COUNTY Dear Permittee: - The subject permit issued on 10/31/88 expires on 9/30/93. North Carolina General Statute (NCGS) 143-215.1(c) requires that an application for permit renewal be filed at least 180 days prior to the expiration date. As of the date of this letter, the Division of Environmental Management had not received an application for renewal. If operation of a discharge or waste treatment facility is to occur after the permit's expiration date, or if continuation of the permit is desired, it must not be allowed to expire A renewal request must be submitted no later than 180 days prior to the permit's expiration date. Operation of the waste treatment works or continuation of a discharge after the expiration date would constitute a violation of NCGS 143-215.1 and could result in assessment of civil penalties of up to $101000 per day. If continuation of the permit is desired, failure to request renewal at least 180 days prior to expiration will result in a civil assessment of at least $250 00• larger penalties may be assessed depending upon the delinquency of the request. A renewal application shall consist of the following information: 1. A letter requesting the renewal. 2. The completed application form (copy attached), signed and submitted in triplicate, referenced in Title 15 of North Carolina Administrative Code (15A NCAC) Subchapter 2H .0105(a). 3. A processing fee (see attached schedule) in accordance with 15A NCAC 2H .0105(b). The application processing fee is based on the design or permitted flow, whichever is appropriate, listed in the first categories of facilities. 4. Primary industries listed in Appendix A of Title 40 of the Code of Federal Regulations, Part 122 shall also submit a priority pollutant analysis in accordance with Part 122.21. 5. Facilities which have not been constructed within the last permit cycle and are therefore, considered `new" facilities, shall also submit an Engineering Alternatives Analysis, referenced in 15A NCAC Subchapter 2H .0103 and Subchapter 2B .0201(c). 6. If the facility covered by this permit contains some type of j. treatment works, a narrative description of the sludge management �. plan must be submitted with the application for the renewal. I' In addition to penalities referenced above, a permit renewal request received after the expiration date will be considered as a new application and will require the higher application fee. 15A NCAC 2H .0105(b)(2) requires payment of an annual Administrative and Compliance Monitoring fee for most permitted facilities. You will be billed separately for that fee (if applicable), after your permit is approved. The letter requesting renewal, the completed Permit application, and appropriate fee should be sent to: Permits and Engineering Unit Division of Environmental Management Post Office Box 29535 Raleigh, North Carolina 27626-0535 The check should be made payable to the North Carolina Department of f Environment, Health, and Natural Resources which may be abbreviated as DEHKR. I If there are questions or a need for additional information regarding the permit renewal procedure, please contact me or any Individual in the NP➢ES Group at telephone number (919) 733-5083. Sincerely, Original Signed Coleen H. Suilinsy Colson Sullins, P.E. Supervisor, NP➢ES Permits Group cc: rck1_aYYlla Regiohal 'Office Permits and Engineering Unit Central Files A ^� RECEIVED Water Quality sartiw C4F' `�Collp JUL 2 3 1990 - ,Asheville Regional Dllite Ashevihti, North aith Ca¢rylitra July 19, 1990 VICTOR BABAOFF BA➢AOFF; VICTOR-SFR A TO C P.O. BOX 6069 ASHEVILLE, NC 28816 SUBJECT: CER'PIFICATE OF COMPLETION PERMIT NO. 0074098AC BABAOFB', VICTOR-SFR A TO C BUNCOMBE; COUNTY Dear Permittee: On June 07, 1989 the Division of Environmental. Management issued you the subject permit. One of the conditions of the subject permit rend as follows: Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the requirements of this permit and the approved plans and specifications. Mail certification to the Permits and Engineering Unit, P.O. Box 27687, Raleigh, N.C. , 27611-7687. To date, our records show that no certification has been received for the subject permit. If the permitted facility has been constructed. and .placed into operation please submit the required certification i.mmed9.atel.y. Operation of the treatment system prior to submission of the required certification is in violation of your permit and is subject to enforcement action. If the facility has not been constructed, please contact the Asheville R�,gioiinl Office at (704)251-6208, so that they can update their records. Thank you for your prompt attention to/]t/hi.s matter. el y1 Donald Sa i.t, P. R. , Supervisor Donald q.i, Permits and Engineer ing Unit cc: File State of North Carolina Department of Natural Resources and Community Development Division of Environmental Management .512 North Salisbury Street•.P.a'.eigh, North Carolhl 27611 James G. Martin,Governor R E C C I v LRCPaul Wilms William W. Colley,Jr.,Secretary June 7, 1989 Water Quality Secfiott Director � Mr.Michael Taylor JUN 15 1989 C/0 WNC Tire PO Box 6069 Ashevill,NC 28816 ,Asheville lieginnal OfficO ,Asheville, North Carolina: Subject: Permit No. AC0074098 Authorization to Construct Victor Babaoff Residence Buncombe County Dear Mr.Taylor: .A letter of request for an Authorization to Construct was received May 2, 1989 by the _ Division and final plans.and specifications fo. the lw' ;oct project hive been.reviewed and found t^ re ,ldsfactory. Authnnza'ion is her F/ &Triil tee_ mr the construodun of a. 480.GPD wastew3icr treatment facility which will consist of a 1,200 gallon septic tank, a distribution box, a 6 feet by 87 feet sand filter, a 130 gallon chlorine contact tank with tablet chlorination and a cascade aerator to serve Victor Babaoff Residence.. This Authorization to Construct is issued in accordance with Part III, paragraph B of the NPDES Permit No. N00074098 issued October 31,1988,and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0074098. The sludge generated from these treatment facilities must be disposed of in accordance with G.S. 143-215.1 and in a manner approvable by the North Carolina Division of Environmental Management, The Asheville Regional Office, telephone number 704/251.-6208 shall be notified at least twenty-four (24) hours in advance of'backfilling of the installed system, so that an in-place inspection can be made. Such notification to the Regional Supervisor shall be made during the normal office hour from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State holidays. If excavation into bedrock for septic tank or sand filter installation is required, the pit shall be lined with a 10 mil synthetic liner. Pollution P.awian Payr P.O.Box 27687,Raleigh,Noah Carolina 27 611-7 6 8 7 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer _ f In event the facilities fail to perform satisfactorily in meeting its NPDBS permit effluent limits, the permittee shall take such immediate corrective action as may be required by this Division, . ,,. including the construction of additional wastewater rralmcnt aitrl facilities. .. The sand media of the subsurface sand filter bed must comply with the Division's sand specifications. Any groundwater quality monitoring,as deemed necessary by the Director, shall be provided. A copy of the approved plans and specifications shall be maintained on file by the Permittee for the life of the permit. One (1) set of approved plans and specifications is being forwarded to you. I£you have any questions or need additional information,please contact Mr. William Barlow, telephone number 919/733-5083. Sincerely, / Pain cc: Buncombe County Health Department l.. Y State of North Carolina Department of Natural Resources and Community Development Asheville Regional Office .,riouernor .ay.,vw, . : 1, ,, ,x. . ;1*. William W. fy^pbey,Jr., Secretary Regional Manager DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION May 19, 1989 MEMORANDUM To: Bill Barlow Permits and Engineerin Through: Forrest R. Westa� ��p�� Regional Water Q Supervisor From: .Max L. Haner - , I Aum Environmental Chemist / ARO Subject: Authorization to Construct AC0074098 Victor Babaoff Residence Buncombe County, North Carolina Subject single family residence (sfr) project has been reviewed and found acceptable. The proposed septic tank-subsurface sand filter system with effluent chlorination and cascade to assist in chlorine removal is typical for those facilities installed to serve sfr projects. The only comment is that the proposed 1000 gallon septic tank appears undersized for a 4 bedroom home. The recommended minimum septic tank size for this project should be 1200 gallons. Also, I have noted that the length of the subsurface sand filter bed is not shown on the drawings, but believe that the original engineering proposal submitted with the NPDES permit application should suffice (copy enclosed herewith) . A 6' x 87' filter will satisfy DEM' s design requirements. It is therefore recommended that the authorization to construct be issued with the condition that a minimum size septic tank of 1200 gallons be provided. Should you wish to discuss this matter in more detail, please advise. MLH 1nwe huw Building, 59%.ft Place, Asheville, N.C.1801 •Telephone] 2516 08 Lr ENGINEERING PROPOSAL Vda� r Qua , �� frn - WASTEWATER•SAND FILTER FER --�aT 6B _ FffiBY1 w no6jN� MAY 2 �� j. g Buncombe County, N.C. May 19, 1988- .Asheville fte !jfce Victor Babaoff , Owner Asheville, llci;ii '.:,I_-,Ira Wastewater Domestic from residence.-f mil -Wa Types Dome 1 a y Flowc 4 Bedrooms at 150 GPD = 600 GPD. Area Required for Subsurface Sand-Filters at 1. 15 LPD/S.F. = 521 square feet. Proposed Filter Bede 6' a 97' with 1B" of filter sand, 0.35 - 0.5 mm effective size, uniformity cosff. < 3.0, dust content < 0,.5%. (- Receiving Streams Reed Creek, trib to Gap Creek, Cane Creek. . Chlarinations Tablet type similar & equal to Sanuril mod. 200, and 130 gal . (min. ) precast concrete contact tank. Aeration/Dechlorinationc Concrete stop cascade with 5 treads 0 l '-011, 5 risers 0 611. Locations K 1 v .s/TB - 5Ryn�1 PO NiiV$ ,moo€e"ssio.Gy ' >¢ SEAL�'t� � -ra 0919hcriew 2OCF CINEE yQPX: ` . MAY` , 19@8 NF'1)1":,% .'rAFF' Rj PORT AND Rl;:COMMP4.DA'1I(:)NE BUNCOMBI" COUNTY c NI DI F'F`RMTT NO. N0007409B PORT I GENERAL INFORMATION i FACILITY AND ADDRESS : VICIOR BABAUFF: RESIDENC.;E 7A 308 9ECRIzIARIAT LANE FAIRVIEW, NORTH CAROLINA 28730 MAILING : X Gl:.ORGE 9111PMAN, BUILDEiR 6? SUNNEYVIEW TERRACE -.:, NORTH CAROLINA 28806 ASHEVILl r. 2. DATE OF INVEE11GOTION: DECEMBER 15, 1987 3. REPORT FREF'ARI 1) BY: MAX I-. IAANER / ARO 4. PERSONS CONIACIED AND lEiLEPHONE NUMBER : POP -SAME, PREVIOUS OWNER 12/1.5/S7 GEORGE SHIPMAN, BUILDER FOR MR.11ABAOFF VIA PHONE 704/2!53-4559 -5. DI.Rr.CTIONS T6 SITE`. ' PROPOSED SITE 19 LOCAHD ADJACENT To SECRETARIAT LANE IN THE FAIRVIEW DOWNS DEVELOPMENT. DEVELOFMEkT 19 LOCATED OFF OF US HWY 7.4 APPROXIMAIELY O.2 MILE SOUTHEAST OF ITS INTERM:TIONMTH NCSR 2776 IN BUNCOMBE COUNTY 61 DISCHARGE 1::'O]:Nl LATITUDE : 35 DP.G. 32 MTN 23 Sf::C: NOR Ti I LONGItUDE : 82 DE(.-,. 2'.5 MIN, 50 SEC,' WES I ATTACJ� 0 UEG.Y MAP -XlRACf AND :INDICATE TREOYMIEN7 FLANI AND DISCHARGE POINT ON Mf)p, USGS QUAD NO. OR L1SGti QUAD MANI:: C 7, S.IZE (LAND AVATI-API-1 FOR F. XP6NS ION AND UF'GRADING) ADI QUAl E H. 70POGRAPHY (RELATIONSHIP 10 FLOOD P! AIN INCLUDED) RFLArIVELY LLVEL Nol IN J:q.00D'PL.A-.[N 9. LOCATION 01:: NEAREST D W I LING : N/A DUIH In T yf"L OF .SY TEM 10 RECEIVING STREAM OR AFFECTED WArEPS : REED CREI 1�- (FRIBUTARY) 11 CLASSI F ICA T 110H : Roul )FJ, RIVER BASIN AND SUBBASIN Mr.), : FRENCH BROAD! RIVER: BASIN i 040302 C Do SCRIBI..: R[,(: -.J,IVTNG Jmj:AjzjRj: S- AND f:'ERfl I WILDIA:JIE I M , AGRICUI TURI..., ANP I'RTBUIARY TO ',�JJREAM (Ly17:D AS INDUSTRIAL WATER SUPPLIi iCANL Pi ED CRI-I. K 1 I T L—m REct�-:1:w�:9 TRIAH.1) A FRANK KASEY Rl.:STD1:AN(lF {N(,'0070602) PAR T 11 DI SCR I P I TON 01:: AND T I 0.::ATM r. W I WORKS t. TYPE OF WASTEWAH.R : 100% DOMESTIC A. VOLUME OF WASFEWAIIER : 0,OWMI3(3 MGD rYF I�ES AND qOANTITII s (.)F IM)U.SIUM. WASIEWAYER: N/A C. PREVALENT TOXI:C C(:)NSIIIUIENTS IN WASTEWATER : N/A N/A D. PRETREATMENT PROG�iAM (POTWI - S ONLY) IN DEVI-LOP MENT APPROVED", SHOULD BE REQUIRED NOT NEEDED I. 2. PRODUCTION RAIE79 (INDUSTRIAL III SCH A R IN PCUN ONLY) D" N/A A. HIGHEST MONTH IN 11HE, LAST i MC II II I lis B. YEAR IN LA31 -3 YE:ARS -rl NI AN M/A DISCRIPTII'lm Of-. I.NDus RIAL PROCE,'�� OFOR INDUSTRIES Y) 1) APPI ICATILE Cl-r PAR'I ND FUDIFART - .R 4. TYPE OF YRI-ATM C3PECIFY WHETHER PROPOSED OR EXISINGD ! THE I KVI..1 0111E 14AS INDICATED MAT THE 9FANDARD SEMIC TANK , SUBSURFACE "'AND F;AAER WIIII EFFLUENT CHLORINATION AND DEC-,IHJ--C)RfHAIfON WILL FIE pROP09ED FOR RiI9 4 BEDROOM RESIDENCE EIZING F'I IF I ECT I 11:1 S I RF A I Mi N as�Al.. SHOULD M- ENGINE SCHIE.M. :1 5. S'l UDGE HANDLING AND DISPOEAl SC HEME NIA, SU::11C TANK WILL TIL PUM11 1:11 AS' NEEDED BY REGUI AR SEMIC TANI( COMPANY AND 1) SPOEED OF Al THE MSD OF BUNCOMBE (.,(JLINIY 6 TIREAIMENT PLANT Cl ASSIFICA I I UN : SIC CODE(S) 4952 WASTEWATER CODES) 04 1 . IS THIS F'ACTLIT.y BEING C;ONSIRLJ[n'EX) WIM CONSIRUCHON CRANTE FUNDS (MUNICIPALS, ONLY)': N/A, kltc I,AL 'm o N:1,TbR.T.N G RE PUES r S NONE" 3 EFF LUE-Ni* 1,IM-US REQUESTS: NONE Wve i 4 0 ffif , AFli ioN 1, M�ENDA T'IONS- IT I Y R lrC (.Jp(11 '-QS'l11,ME COMMENTS FROM D"7UA PPI -�6NC 10 ptDLqog P14 ESSLJED i. 3 Grin I#Lm" IlY �rFaci l ity Namei. Perm, I ; AL M7(3Q5 (f l� F�Titt huf _�o_ Piece �� ingSi Stream: Lass .l[�///T Str(G�-Basin � —Q2— ' Cour ;ya F7 JAB ' R.pgionel - Reference USGS Ouad . N G Exis ping: Proposed : Elevation : A31S0 41 Drainage Area : �• 4.2 " C� Z Hydrolocic Grcuo : Design Temperature : slope ; , Commer. l . -CO m, I �eoc�eGaeG�y� rRruQ r[�c4g e I ' - RECOL!MENDEDDi EFFLUENT rr LIMITS _ D .D. DH Fecal Coli [ / 100m17 : _ _ /,Q7tiKQ TSS (mg/ 1 ) : _�Q— ,••�%� — IZ&2 �n9i e� Ord � Q REccMMENDED B'—. C. Dater APPROV'D EV : R ec : ine . __ngi veer ^._� Dat _ Re SC 'ac nni e ' S:r,; : cu;. end Permits Unit _vp% .,f US„., 'h ..n ! mar, diseharccr . �e..., NORTH CAROLINA DEPT�FF NATURAL ]RESOURCES AND CONNITY DEVELOPMENT ENVIRONMENTAL MANAG"}fiT COMMISSION Y�f NATIONAL POLLUTANT La CHARGE ELIMINATION SYSTEM AppucanaN xue6ta APPLICATION FOR PERMIT TO DISCHARGE .a SHORT FORM D FOR ) 0 U AGENCz RIC USE DATE RECEIVED To be filed only b9 services, wholesale and retell trade, and other commercial establishments including ,vessels YEAR NO, - DAY 00 not attempt to complete this form without reading the accompanying instructions Please print or type 1. Neme, address, and telephone number of facility producing discharge _ A. Name Victor Babaoff U. Street address 308 Secretariat Lane C. City Fairview Two. D. State N.C. _ E. 'county Buncombe - F. ZIP 28730 G. Telephone No. 04 254-9141 Area Code 2, SIC ® MAY 6.198E (Leave blank) PERMITS!'& ENGINEERINC 3. Number of employees N/A s� 4. Nature of business 1-family Residence S. (a) Check here 1f discharge actors all year d, or (b) Check the months) discharge occurs: 1.OJanuary 2.0February - 3.a March 4.0 April S.a May j6.0 June 7.a July B.O August 9.0 September 10.a October 11.0 November 12.a December (C) Now many days per week: 1.01 2.02-3 3.04-5 4.156-7 6. Types of waste water discharged to surface waters only (check as applicable) Flow, gallons per operating day Volume treated before discharging (percent) Discharge Per operating day 0.1-999 IODO-4999 5000-S999 10,000- 50,000 None 0.1- 30- 65- 95-U _:. 49 c99 ,pr¢ .ipte . .- 29.9 64.9 94,9 i 100 (1) (2) (3) (4) (5) (6) (7) (8) (9) (10) A. SaniLI ry, daily _ average x x 8. Cooling water, etc., daily average C. Other discharge(s), daily average; Specify D. Mamma. per operat- ing day for combined x a discharge (all types) a. tr any or the types 9f waste iapnSliftea ro rtam fa miner s. check or un /A it any o are dtadnar ad to pl Mar than surface waters. check Oelpy ' - as applicable.' Wastewater is discharged to: 0.1-999 "1000-e999 "5000-9999 10,000-49.999 50.000 or more (1) (2) (3) (4) (5) I A, Municipal scum system 0, undrr9rmnul wrll 6 I C. Septic tank D. Evaporation lagoon or pond - E. Other, specify: ...; ..,_...:_ .._. .. _. 8. Number of separate discharge points: A:dlb 8.02-3 C.D 4-5 D.o6 or more 9. Name of receiving water or waters Reed Creek, trib. to Gap Creek, Cane Creek 10. Does your discharge contain or is-it possible for your discharge to contain one or more of the following substances caeca as a result of your operations, activities, or proeesseft aammnia, cyanide,-aluminum, beryllium, cadmium, chromium, copper* dead, mercury. nickel, selenium, zinc, phenols, oil and grease. and chlorine (residual). A.15yes 0.13 no 1 certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. Michael A. Taylor Printed Name of Person Signing Agent (Power of Attorney attached) Title_ ApW LI} 1 88 ) Date Application Signed 5 gnat re of Applicant arch Carolina General Statute 143-215.6(b) (2) provides that: Any person who knowingly makes Icy false statement representation, or certi ication in any application, record, report, plan, r: other document files or required to be maintained under Article 21 or regulations of the novironmental Management Commission implementiag that Article, or who falsifies, tampers with, lip rr knowly renders inaccurate any:recording or monitoring device or method required to be ! Oersted or maintained under Article 21 or regulations of the Envitontriental Management Cotmaissic mplementing that Article, shall be guiltv of amisdemeanor punishable by a fine not to exceed 3L0,000, or by imprisonment not to. exceed six months, or by both. (15 U,S.C. Section 1001 provid . punishment by a fine of not more than $10,000 or imprisonment not mare than 5 years, or both, r car a similar offense.) o Aq � MAY g Pf�MITg& FNG.11908E 04/13/BB i. GENTLEMEN: I WOULD LIKE TO GIVE MR. MIKE TAYLOR THE POWER OF ATTORNEY TO SIGN OR MAKE COMMITMENT ON MY BEHALF CONCERNING MY HOUSE BEING BUILT AT FAIRVIEW DEVELOPMENT. SINCERELY, VICTOR BABAOFF owe 11n, Ot "M ".rONg 00 l UP. 11Z Lk 4E- Tt'�" 'A Fill 91 W MEN, State of North Carolina Department of Natural Resources and Community Development Division of Environmental Management 512 North Salisbury Street•Raleigh,North Carolina 27611 James G.Martin,Governor R. Paul Wilms William W.Coley,Jr.,Secretary Director May 3, 1989 MEMORANDUM To: Forrest Westall Asheville Regional Office/WQ Supervisor From: William Barlow Raleigh, Central Office Subject: AC0074098 Please Provide Comments. PollutionPrm,an ion Pays P.O.Box 27687,Raleigh,North Carolina 276117687 Telephone919-733-7015 An Equal Opportunity AfCumnfive Acton Employ" r � Vl �. TnR Q �:QPdFI R�S �DXNcr_ S �i'� P121M 44 kAst' ces - o w s 24 De Ve lnew,q.. . d J v ■� I' d1 ..t $treq... yY Qev\r. li 11 �� IJO\N - CaSCaq[ "A t^e11 ht'o 1 � 1_ N�ONIKA +OY �^ BbAL---�o 11—se— sgpfi;� T3rk \o nMUG WAS Wn'Yer 3�. 1 �eccc�Cdr�a� �..A\ne State of North Carolina Department of Natural Resources and Community Development Division of Environmental Management 512 North Salisbury Street •Raleigh, North Carolina 27611 James G. Martin, Governor R. Paul Wilms S. Thomas Rhodes, Secretary October 31, 1988 Director Mr. Michael Taylor C/O WNC Tire PO Box 6069 Asheville, NC 28816 Subject: Permit No. NCO074098 Victor Babaoff Residence Buncombe County Dear Mr. Taylor: In accordance with your application for discharge permit received on May 6, 1988, we are forwarding herewith the subject State - NPDES permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215. 1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated December 6, 1983. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you may request a waiver or modification pursuant to Regulation 15 NCAC 2B .0508(b) by written request to the Director identifying the specific issues to be contended. Unless such request is made within 30 days following receipt of this permit, this permit shall be final and binding. Should your request be denied,. you .will have the right to request an adjudicatory hearing. Please take notice that this permit is not transferable. Part II, D.3. addresses the requirements to be followed in case of change in ownership or control of this discharge. This permit does not affect the legal requirements to obtain other permits which may be required by .the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Mr. Mack Wiggins telephone number 919/733-5083. Sincerely, RECEIVED Signed By ARTHUR MOUSERRY Water Quality Section R. Paull'WRlms cc: Mr. Jim Patrick, EPA NOV 3 _ 1988 Ponseon Preuenaon anys AshevilleRegioe al Ofla Asheville, Ncrth Carolilina P.O.Box 27687, Raleigh,North Camuna 2701-76U Telephone 919-733-7015 01 An Equal Oppomnlry A(Renafiw Acdon Employer i . ` �Permit No. NC0074098 . STATE OF .NORTH CAROLINA DEPARTMENT OF NATURAL RESOURCES & COMMUNITY DEVELOPMENT DIVISION OFENVIRONMENTAL -MANAGEMENT P E R M I T - To Discharge Wastewater Under The NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provisions of North Carolina General . 'Statute 143-215. 1 , other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Mr. Victor Babaoff is hereby authorized to discharge. wastewater from facilities located at Babaoff Residence adjacent to Secretariat Lane, Lot #68 Fairview Downs Subdivision Buncombe County to receiving waters designated as Reed Creek in the French Broad River Basin in accordance with effluent limitations , monitoring requirements , and other conditions set forth in Parts i, II, and III hereof . This permit shall be effective October 31, 1988. This permit and the authorization to discharge shall expire at midnight on .September 30, -1993. Signed this day of October 31, 1988. d By ARIHUR M USERRY - I. Fot: -- --- i. R, Paul Wilms—,--Dire—cto-- ------ r Division of Environmental Management By Authority of the Environmental Management Commission emit No.. NC0074098 SUPPLEMENT TO PERMIT COVER SHEET Mr. Victor Babaoff is hereby authorized to: 1 . Enter into a contract for construction of a wastewater treatment facility, and 2. Make an outlet into Reed Creek, and 3. After receiving an Authorization to Construct from the Division of Environmental Management, construct and operate a 480 GPD wastewater treatment facility located adjacent to Secretariat Lane, Lot #68 in Fairview Downs Subdivision in Buncombe County (See Part III of this permit) , and 4 . Discharge from said treatment works into Reed Creek which is classified Class "WS-III - Trout" waters in the French Broad River Basin. a d p 6 H N H Y Y H a dPWII p q Y p a v H Rl H q m q W H d Y d P N Y H O D U I d N Y W d m d V ro A W ro O L z .I p u WI Hri H Nd q q z W H Y P P \\ O\ d q ro H roH W 6 mOp O m Ari L Y MMH - it Tl H add d HI OO Ot+l Yd N O N _ H pi ri d d .t V O Y F W d W H L NI 3 O Y d rl ' d ro L q N N d M A I A W O Y NW 00 H Y Y P +iI H rl G O N z z O o ul C A \\ o \ d o p w p v .i N W 00 O 0p H H d O N mi d PI V 6 0. "I 6 O Y w O w S H O M L 'i \ Y U Y I 0 0 0 O N d o Y T w p •q O O v d GI o00 00 p d m o �'+ �'+OI m o W w. N 6 HI �I co v G v Io m m I Tl N q p H A M HI d p W M w Y •O •p PI •I L O Y Y o v m O p m ro H O Y 51 o m•O W, TI p p .o W p vH roHI q ++ o w ro z q N A m d I A H L d 6 H O A •31 O Y pp DD L H v U .i W N i U] d Y ri I N ri N W z A p 5 NI •I d H d ro N N A O d L OI T 0pi p Y g L Y d U H 'O N HI. ro PI F o N O O N A d R1 H H d H I 00 T d d H O N A H d U b0 HI P4 HI w OOL Y Y O wv N dl A �U ro u d F u v YI YI ro G d o a d Y L u l p d R H H p p d AMU rol O U 'O Hro N A F u g N NI zI Oo q O p p o H z H ++ ro l w 00 d 'O AI N 0. +-I H H L rl ro H O p c UI m 0 m p u L L d a H L P p 2 d _d u o m L W H N U YI N fn U C4 N d m W GL G p A m N L W w ouw dl �nHroHHd Eo a a pl 3 • ro d ro a H HI O q u m o u 2 v d d WI W aiEz W.FE F F wl PART I "Act" used herein means the Federal Water Pollution Control Act, As Amended. "DEM" used herein means the Division of Environmental Management of the Department of Natural Resources and Community Development. "EMC" used herein means the North Carolina Environmental Management Commission. Definitions a. The monthly average, other than for fecal coliform bacteria, is the arithmetic mean of all the composite samples collected in a one-month period. The monthly average for fecal coliform bacteria is the geometric mean of samples collected in a one-month period. b. The weekly average, other than for fecal coliform bacteria, is the arithmetic mean of all the composite samples collected during a one-week period. The weekly average for fecal coliform bacteria is the geometric mean of samples collected in a one-week period. c. Flow, M3/day (MGD) : The flow limit expressed in this permit is the 24-hour average flow, averaged monthly. It is determined as the arithmetic mean of the total daily flows recorded during the calendar month. d. Arithmetic Mean: The arithmetic mean of any set of values is the summation of the individual values divided by the number.of indi- vidual values. e. Geometric Mean: The geometric mean of any set of values is the Nth root of the product of the individual values where N is equal to the number of individual values. The geometric mean is equivalent to the antilog of the arithmetic mean of the logarithms of the indi- vidual values. For purposes of calculating the geometric mean, values of zero (0) shall be considered to be one (1) . PART 11 A. MANAGEMENT REQUIREMENTS 1. Change in Discharge All discharges authorized herein shall be consistent with the terms and conditions of this permit. The discharge of any pollutant identified in this permit more frequently than or at a level in excess of that authorized shall constitute a violation of the permit. Any anticipated facility expansions, production increases, or process modifications which will result in new, different, or increased discharges of pollutants must be reported by submission of a new NFDES application or, if such changes will not violate the effluent limitations specified in this permit, by notice to the DEM of such changes. Following such notice, the permit may be modified to specify and limit any pollutants not previously limited. 2. Facilities Operation The permittee shall at all times maintain in good working order and operate as efficiently as possible all treatment or control facili- ties or systems installed or used by the permittee to achieve com- pliance with the terms and conditions of this permit. 3. Adverse Impact The permittee shall take all reasonable steps to minimize any adverse impact to navigable waters resulting from noncompliance with any effluent limitations specified in this permit, including such accel- erated or additional monitoring as necessary to determine the nature and impact of the noncomplying discharge. 4. Bypassing Any diversion from or bypass of facilities necessary to maintain com- pliance with the terms and conditions of this permit is prohibited, except (i) where unavoidable to prevent loss of life or severe property damage, or (ii) where excessive storm drainage or runoff would damage any facilities necessary for compliance with the effluent limitations and prohibitions of this permit. The permittee shall promptly notify the Water Quality Section of DEM in writing of each such diversion or bypass. i 5. Removed Substances f Solids, sludges, filter backwash, or other pollutants removed in the f course of treatment or control of wastewaters shall be disposed of in i. a manner such as to prevent any pollutant from such material from entering waters of the State or navigable waters of the United States. III. PART II 6. Power Failures In order to maintain compliance with the effluent limitations and prohibitions of this permit, the permittee shall either: a. Provide an alternative power source sufficient to operate the wastewater control facilities; or, if such alternative power source is not in existence, b. Halt, reduce, or otherwise control production and/or all dis- charges from wastewater control facilities upon the reduction, loss, or failure of the primary source of power to said waste- water control facilities. B. RESPONSIBILITIES 1. Right of Entry The permittee shall allow the Director of the Division of Environ- mental Management, the Regional Administrator, and/or their author- ized representatives, upon the presentations of credentials: - a. To enter upon the permittee's premises where an effluent source is located or in which any records are required to be kept under the terms and conditions of this permit; and b. At reasonable times to have access to and copy any records required to be kept under the terms and conditions of this permit; to inspect any monitoring equipment or monitoring method required in this permit; and to sample any discharge of pollutants. 2. 'Transfer of Ownership or Control This permit is not transferable. In the event of any change in con- trol or ownerahip of facilities from which the authorized discharge emanates or is contemplated, the permittee shall notify the prospec- tive owner.or controller by letter of the existence of this permit and of the need to obtain a permit in the name of the prospective owner. A copy of the letter shall be forwarded to the Division of Environmental Management. 3. Permit Modification After- notice and opportunity for a hearing pursuant to NCGS 143-215.1 (b)(2) and NCGS 143-215.1(e) respectively, this permit may be modi- fied, suspended, or revoked in whole or in part during its term for cause including, but not limited to, the following: PART II a. Violation of any terms or conditions of this permit; b. Obtaining this permit by misrepresentation or failure to disclose fully all relevant facts; or c. A change in any condition that requires either a temporary or permanent reduction or elimination of the authorized discharge. 4. Civil and Criminal Liability Except as provided in permit conditions on "Bypassing" (Part II, A-4) and "Power Failures (Part II, A-6), nothing in this permit shall be construed to relieve the permittee from civil or criminal penalties for noncompliance pursuant to NCGS 143-215.6 or Section 309 of the Federal Act, 33 USC 1319. 5. Property Rights The issuance of this permit does not convey any property rights in either real or personal property, or any exclusive privileges, nor does it authorize any injury to private property or any invasion of personal rights, nor any infringement of Federal, State, or local laws or regulations. 6. Severability The provisions of this permit are severable, and if any provision of this permit, or the application of any provision of this permit to any circumstance, is held invalid, the application of such provision to other circumstances, and the remainder of this permit shall not be affected thereby. 7. Expiration of Permit Permittee is not authorized to discharge after the expiration date. In order to receive authorization to discharge beyond the expiration date, the permittee shall submit such information, forms, and fees as are required by the agency authorized to issue permits no later than 180 days prior to the expiration date. Any discharge without a permit after the expiration will subject the permittee to enforce- ment procedures as provided in NCGS 143-215.6 and 33 USC 1251 et seq. . PART III A. PREVIOUS PERMITS All previous State water quality permits issued to this facility, whether for construction or operation, or discharge, are hereby revoked by issuance of this permit. The conditions, requirements, terms, and provisions of this permit authorizing discharge under the National Pollutant Discharge Elimination System govern discharges from this facility. B. CONSTRUCTION No construction of wastewater treatment facilities or additions thereto shall be begun until Final Plans and Specifications have been submitted to the Division of Environmental Management and written approval and Authorization to Construct have been issued. If no objections to Final Plans and Specifications have been made by the DEN after 30 days follow- ing receipt of the plans or issuance of this permit, whichever is latter, the plans may be considered approved and construction authorized. C. SPECIAL CONDITIONS 1. The Permittee shall be responsible for the following items regard- . - ing the maintenance of the treatment system: a. Septic tanks shall be maintained at all times to prevent seepage of sewage or effluents to the surface of the ground. b. Septic tanks need routine maintenance and should be checked at least yearly to determine if solids need to be removed or other maintenance performed. c. Contents.removed from septic tanks shall be discharged into an approved sewer system, buried or plowed under at an approved location within 24 hours, or otherwise disposed of at a location and in a manner approved by the State or local agency. 2. The permittee shall properly connect to an operational publicly- owned wastewater collection system within 180 days of its availability to the site. PAT MCCRORY :+ sw1 co�amo. DONALD R. VAN DER VAART _ Seoremry Water Resources S. JAY ZIMMERMAN ENVIRONMENTAL QUALITY Dlrecmr {{ 1 February 26, 2016 _ 1 i Victor Babaoff 308 Secretariat Lane Fletcher,NC 28730 i j SUBJECT: Compliance Evaluation Inspection 308 Secretariat Lane Permit No: NCG550475 Buncombe County i ) Dear Mr. Babaoff: - Enclosed please find a copy of the Compliance Evaluation Inspection Report for the inspection ,! conducted on February 18, 2016 at your single family residence wastewater treatment system at = 308 Secretariat Lane. Please read this report carefully and take note of any comments that are listed. Although no water quality violations were observed, your system was found to be out of compliance with NPDES Permit No.NCG550475. Annual effluent water quality monitoring has not been conducted since 2011. Other violations observed include failure to check the septic tank annually to see if solids need to be removed and failure to pump out the septic tank at least every 5 years. . 9 i Ensure chlorination tablets are certified for wastewater use as wastewater tablets are not the same as those used for swimming pools. Maintain all permit required records. 1 Within thirty(30) days upon receipt of this letter,please submit a corrective action plan and any documentation to the undersigned addressing the non-compliance identified in this report. If .additional time is needed to return to full compliance,please include anticipated completion dates in your letter. Failure to complete remedial measures in a timely manner may result in a i Notice of Violation and the assessment of civil penalties. j, 1 1 SlaWduaMC.1ina I EnviromnentAQmity1 WU,ii RAM.rc Asheville Regional Qpaanons Center { 2090 M 7011,h—y,S—urt ia,Nonh Carollna28778 828296.4500 T { i Refer to the enclosed inspection report for additional observations and comments. If you have any questions,please call me at 828-296-4500. -_ I t j ' I . i Sincerely, Rob Topolski 1 Environmental Specialist Division of Water Resources � I Enclosure: Inspection Report l 1 cc: MSC 1617-Central Files-Basement {I WQ Asheville Files i 0:\WR\WQ\Buncombe\Wastewater\General\NCG55 Single Family Residence\550475 Victor Babaoft\CE1.02182016.11r.doc � II � Ir it � i � I F it United elalee Emlion astal P'Osdrion Agenny Form Approved. EPA WseNn9doq C.C.20460 OMB No.2040-0067 Water Compliance Inspection Report Approval expires 8-31-98 Section A:National Data System Coding(Le.,PCS) Tom sacl an Code NPDES yllmolday, Inspection Type Inspector F.0 Type 1 IN 2 15 1 3 NCG550475 11 12 1fiN2liB 17 18r.1 191e 20I 211 u1I66 Inspection Work Days Facility Self-Monitoring Evaluation Raying B1 GA ---------Reserved------- 67I 70I LJ 71.� 1 72 ( u 731 p-0 75 I , I I80 I1 Section B:Facility Date L.J Name and Location of Facility Inspected(For Industrial Users Cischarglngto POi also Include Entry Timeloade Permit Ell Data POTW.nema and NPDES munst Number lani 161OV18 1WO8101 308 Secretariat Lane 308 Secretariatln - Exit ound ate Permit Expiration Date Fairview INC 28730 10:20AM 16102118 1810751 Nme(e)of Onside RepresentatlVitiumilles(skyPhOne and Fax Numbers) Other Facility Data 111 1 Name,Address of Responsible Olfi ielRiBo/Phone and Fax Number Victor Babaoff,308 Scombril Fairview NC 287301I8282549141/8282549779 Garlanded Vas Section C:Areas Evaluated During Inspection(Check only those areas evaluated) Permit Operations 8 Maintenance E Facility Site Review EBIuentlReceiving.Waters `I j Section D:Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) 1 U (See attachment summary) j I Nedi ad Signature s(of uspectai Agency/Ofllae/Phone antl Fax Numbers `� Date Raided Topaieki ARO WDI/828296-0fi00/ - /r�6 /� ) Andrew A Moore ARO WO/1828-29646841 Signature of Management O A Reviewer Agency/ORcelPhone antl Fax Numbers Data I EPA Form 31(Rev9-94j Previous ii ions are obsolete. ] Page# 1 7. NPolrs yrlmolday Inspection Type (Cont.) 1 3 NCG550475 11 12 ifil02lia 17 18 [�Ij s Section e:Summary of Finding/Comment (Attach additional sheets of narrative and checklists as necessary) On February 18,2016, 1 (Rob Topolski)and Andrew Moore of the Asheville Regional Office conducted a compliance evaluation inspection at the 308 Secretariat Lane single family residence wastewater treatment plant. The homeowner, Mr.Victor Babaoff,was present during the inspection and showed 7 us the various components of the system. He said the septic tank, located next to the back of the 1 house, has a 1,200 gallon capacity and has never been pumped out. Septic tanks need to be checked annually and pumped out if more than 113 of the capacity is filled with solids or every 3-5 years. Chlorine tablets were present, but total residual chlorine was not analyzed at this time. The effluent wet well works as a chlorine contact chamber and the discharge to.the receiving stream was relatively clear. The receiving stream was flowing clear with no signs of degradation from this discharge. Samples were not collected at this time. Annual monitoring required by the general permit has not 3 - been conducted since 2011. 1 Mr. Babaoff contacted the Asheville Regional Office on February 19,2016 and spoke with Andrew Moore about permit requirements. He said that he planned to commence the annual compliance monitoring, but needed to know what parameters to have a state certified laboratory analyze for. Mr. Moore emailed Mr. Babaoff a copy of the NCG550000 General Permit and a copy of his most recent analytical report(9/15/2011). Annual fees have been paid and permit status is active. - rl t I , r ) I_ i � d s l 7 I , j 1 j i Page# 2 n Permit: NCO550475 Owner-Facility: 308secratariet Lan. Inspection Date:'0211812016 Inspection Type'. Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ M ❑ application? Is the facility as described in the permit? ❑ 0 ❑ ❑ #Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? ❑ ❑ 0 ❑ Is the inspector granted access to all areas for inspection? M ❑ ❑ ❑ Comment: The facility is not as described in the permit application approved by the Division The site Ian depicts a cascade aerator after chlorine contact and before discharge to the receiving stream. The chlorine contact tank is designed with afloat switch pump which may produce adequate dissolved oxygen in lieu of cascade aeration Operations &Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters,for ex:MLSS,MCRT,Settleable ❑ ❑ 0 ❑ Solids,pH, DO,Sludge Judge,and other that are applicable? Comment: i I Septic Tank Yes No NA NE (If pumps are used)Is an audible and visual alarm operational? ❑ ❑ IN ❑ Is septic tank pumped on a schedule? ❑ 0 ❑ ❑ '' I Are pumps or syphons operating properly? - ❑ ❑ 0 ❑ Are high and low water alarms operating properly? ❑ ❑ M ❑ 1 Comment: The septic tank is reported to be 1,200 gallon capacity with one part time resident. Mr. Babaoff said that he has never had the tank dumped The effluent was relatively clear 1 indicating properly functioning systems' however,the Division recommends checking the - septic tank every year to see if solids should be removed and having solids pumped out of the tank every 3-5 years. I Sand Filters (Low rate) Yes No NA NE (If pumps are used)Is an audible and visible alarm Present and operational? ❑ ❑ M ❑ J 1 Is the distribution box level and watertight? ❑ ❑ ❑ 0j Is sand filter free of pending? 0 ❑ ❑ ❑. j Is the sand filter effluent re-circulated at valid ratio? ❑ ❑ 0 ❑ III I #Is the sand filter surface free of algae or excessive vegetation? ❑ ❑ ❑ j 1 #Is the sand filter effluent re-circulated at a valid ratio?(Approximately 3 to 1) ❑ ❑ ❑ 3 1 ' Page# 3 ( ( n n Permit: NOG550415 Owner-Fadllty', 208 secretariat Lane Inspection Date: 02/18/2016 In...Olen Typ.: Compllence Evenorlon - Sand Filters (Low rate) Yes No NA NE Comment: The sand filter is buried and covered with grassy lawn. No pending or wet soots were . observed. -] � l Disinfection-Tablet Yes No NA NE Are tablet chlorinators operational? 0 ❑ ❑ ❑ Are the tablets the proper size and type? 0 ❑ ❑ ❑ Number of tubes in use? 1 � Is the level of chlorine residual acceptable? ❑ ❑ ❑ Is the contact chamber free of growth,or sludge buildup? M ❑ ❑ ❑ Is there chlorine residual prior to de-chlorination? ❑ ❑ M ❑ Comment: Due to low flow conditions. Mr. eabaoff said that he was instructed to only use one of the two tablet tubes. Samples were not collected at the time of this inspection to determine optimum operation. Pump Station - Effluent Yes No NA NE Is the pump wet well free of bypass lines or structures? ❑ ❑ ❑ Are all pumps present? 0 ❑ ❑ ❑ Are all pumps operable? 0 ❑ ❑ ❑ i Are float controls operable? 0 ❑ ❑ ❑ Is SCADA telemetry available and operational? ❑ ❑ M ❑ Is audible and visual alarm available and operational? ❑ ❑ M ❑ �. . . I Comment: The effluent wet well serves as a batch chlorine contact chamber, The Pump cycled one time during this inspection The effluent shot into the air and into the receiving stream. No. cascade aeration device was present as indicated in the original permit aoolicatiom however,there were no erosion issues observed and adequate dissolved oxygen maybe acheived. Effluent Pine Yes No NA NE Is right of way to the outfall properly maintained? _ ❑ ❑ ❑ , Are the receiving water free of foam other than trace amounts and other debris? M ❑ ❑ ❑ `s , i If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The off ruent was relatively clear and the receiving stream was flowing clear. Stream degradation was not observed. y � i Pages 4 j Mite's SEPTIC TANK SERVICE P,Q, Box 968• Leicester, Ni"28748 «�. �,• (826)253 2612•Cell 775-1658 ` Michael Lusk,Jr. CUSCMIEP WOEP NO. PHON6 =7 7 77,;; I 2 L t //'' IUME s Q1 V DEGENED BY :TOTAL `,1•y!X All Claims and returned goods War he. - eGccmpanied by this bill Picked up and delivered,. TOW m /1 Pace Analytical Services,Inc. aceAnalXical. e,NC 28°r ASM1eville,NC 28804 mmpbLBIBW.svm (828)254-7176 March 24, 2016 Private Client Private Client Private Client Asheville, NC 28804 RE: Project: Victor Babgoff Effluent - Pace Project No.: 92290429 Dear Private Client: Enclosed are the analytical results for sample(s) received by the laboratory on March 17, 2016. The results relate only to the samples included in this report. Results reported herein conform to the most current TNI standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. Analyses were performed at the Pace Analytical Services location indicated on the sample analyte page for analysis unless otherwise footnoted. If you have any questions concerning this report, please feel free to contact me. Sincerely, Denise Trentham denise.trantham@pacelabs.com Project Manager Enclosures REPORT OF LABORATORY ANALYSIS This report shall not be repmducel,except in full, without the writthn consent of Pace Analytical services,Inc.. Page 1 of i t i Pace Analytical Services,Inc. aceAnalytical® ) ) 2425 28 Di Asheville, NC NC P9ao4 mm:pecelehavom te1-7178 CERTIFICATIONS Project: Victor Bari Effluent Pace Project No.: 92290429 Asheville Certification IDs 2225 Riverside Drive,Asheville,NC 28804 North Carolina Wastewater Certification#:40 FlondaMELAP Certification#:E87648 South Carolina Certification#:99030001 Massachusetts Certification#:M-NC030 VirginiaA/ELAP Certification#:460222 North Carolina Drinking Water Certification#'.37712 I l REPORT OF LABORATORY ANALYSIS This reportahell not be reproduced,except In full, without the written consentof Pace Analytical services,mc. Page 2 of 11 Pace Analytical services,Inc. aceAnalytical® 2225 Riverside Dr Ashavile,NG 26804 avet'shemle. (628)254-71I6 SAMPLE ANALYTE COUNT Project Victor Sabgoff Effluent - Pace Project No.: 92290429 Analyles Lab ID Sample ID Method Analysts Reported Laboratory 92290429001 Effluent-Grab SM 2540D MSH 1 PASI-A SM 5210E MILS 1 PASI-A SM 9222D TEP 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shell not be hapmtlupeh,except in full, wilhout the watch consent of Pace Analysbal Services,Inc.. Page 3 of 11 r p Pace Analytical Services.Inc. ace Analytical® 225 Riv 28 ASM1eville,NO 904 wtm:pewleMmm (626)254-]1]6 ANALYTICAL RESULTS Project: Victor Babgoff Effluent Pace Project No.: 92290429 Sample: E5luent-Oreb Laidig: 92290429001 Collected 03/17/1610'.35 Received 03/171161055 Matrix:Water Parameters Results Units Report Limit OF Prepared Analyzed CAS No Qual 6 2640D Total Suspended Solids Analytical Method:SM 2540D Total Suspended Solids 2.6 mg/L 2.5 1 03117MIS 16:36 521015 SOD,5 day Analytical Method:SM 5210B i- BOO,5 day ND mg/L 2.0 1 03/18/1611:35 03123/1613:30 MBIO 9222D Fecal Collform AVL Analytical Method:SM 9222D Fecal Coliforms NO CFU/l00 mL ID 1 031 7/1616:35 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced.except In full, Date:03/24/201611:43 AM sanest the writer,consent of Pace Analytical Services,Inc. Page 4 of 11 ® ASPace Analytical services,Inc. =Analytical 225 RiversideDr. M1ev NCC282eap4 wnw.OaR?IBAauwn (82628)25¢]1]6 QUALITY CONTROL DATA Project: Victor Babgofi Effluent Pace Project No.: 92290429 QC Batch: WET/43646 Analysis Method: SM 2540D QC Balch Method: SM 2540D Analysis Description: 254013 Total Suspended Solids Associated Lab Samples: 92290429001 METHOD BLANK: 168888B Matrix'. Water Associated Lab Samples: 92290429001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg/L ND 2.5 03/17/1616:32 LABORATORY CONTROL SAMPLE: 1688889 Spike LCS LCS %Rec Parameter Units Cons. Result %Rec Limits Qualifiers Total Suspended Solids ri 250 235 94 90-110 SAMPLE DUPLICATE: 1688890 92290423001 Cup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 124 163 27 J(D6) SAMPLE DUPLICATE'. 1688891 92290370001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 51D 53.2 3 Results prommus on this page are In the unite Indicated by the Units column moved xfiere an alternate unit In presented ti the hard or the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced,except in full. Date:0 3/24/2 016 11:43 AM without the written consent of Pace Analytical services,Inc.. Page5cf11 /tea �a Pace Analytical Services,Inc. aceAnalytical® , , 2225 ki eraide On Hsheville,NO 28804 nmy'sualebaunm (828)25441I6 QUALITY CONTROL DATA Project Victor Babi Effluent Pace Project No.: 92290429 QC Balch: WET/43686 Analysis Method: SM 52108 OC Batch Method: SM 5210B Analysis Description: 5210B BOD,5 day Associated Lab Samples: 92290429001 METHOD BLANK: 1690261 Matrix: Water Associated Lab Samples: 92290429001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers BOD,5 day mi ND 2.0 03123/1613:30 LABORATORY CONTROL SAMPLE: 1690262 Spike LCS LCS %Rec Parameter Units Conn Result %Rec Limits Qualifiers BOO day mi 198 169 85 84.6-115.4 SAMPLE DUPLICATE: 1690263 92290536001 Dup Parameter Units Result Result RPD Qualifiers BOD,5day mg/L 4.7 4.8 2 I Results presented on this page are inthe units Indicated by the"nnlla'column except scheme an alternate unit Is presented to the r ghtortba ma g REPORT OF LABORATORY ANALYSIS This repast shell not be reproducts,except m lull, Date'.0 3124/2 016 11:43 AM without Ho wmten consent of Pace Analytical Services,Inc. Page6of 11 Pane Analytical serer ass,In.. ® ) / 2225 Riverside Dr. ace Anal) ieal As„evil,¢,NC 29804 mactineek6s. (828)254-]1]6 QUALITY CONTROL DATA Project: Victor Bari Effluent Pace Project No.. 92290429 QC Batch: WET/43653 Analysis Method: SM 9222D QC Batch Method'. SM 9222D Analysis Description: 9222D MBIO Fecal Coliform-AVL Associated Lab Samples: 92290429001 METHOD BLANK: 1689168 Matrix: Water Associated Lab Samples: 92290429001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Fecal Colifarms CFU/100 mL ND 1.0 03/17/1616:35 SAMPLE DUPLICATE: 1889169 92290429001 OUR Parameter Units Result Result RPD Qualifers Fecal Coliforms CFU/100 mL ND NO Results scesses on ia.pa,.he In the ni launched by the"6rits'column except atere an enemtle unit le presented to the dghtaf t„e reeutl. REPORT OF LABORATORY ANALYSIS This report that not be repmduced,except in full, Date:031241201611:43 AM wifrouture written consent of Pace Analytical services Inc, Pageyofll Pace Anelytieal Services,the. 222510 coda Or. rlV4r n��r}�'riGl Asbevllle,NC Hobe avw.Pecala4&me (828)254-0116 QUALIFIERS Project: Victor Babgoff Effluent Pace Project No.: 92290429 DEFINITIONS DF-Dilution Factor,if reported,represents the factor applied to the reported data due to dilution of the sample aliquot. ND-Not Detected at or above adjusted reporting limit. MDL-Adjusted Method Detection Limit. PQL-Practical Quanthation Limit. RL-Reporting Limit. S-Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270,The result for each analNe is a combined concentration. Consistent With EPA guidelines,unrounded data are displayed and have been used to calculate%recovery and RPD values. LCS(D)-Laboratory Control Sample(Duplicate) MS(D)-Matrix Spike(Duplicate) CUP-Sample Duplicate RPD-Relative Percent Difference NC-Not Calculable. SG-Silica Gel-Clean-Up U-Indicates the compound was analyzed for,but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether,Styrene,and Vmyl chloride. A separate vial preserved to a pN of 4-5 is recommended in SW846 Chapter 4 for the analysis ofAcmlem and Acrylonitrile by EPA Method 8260. N-Nitmsodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270, The result reported for each analyle is a combined concentration. Pace Analytical is TNI accredited,Contact your Pace PM for the current list of accredited analyses. TN -The IN SLAG Institute. LABORATORIES PASI-A Pace Analytical Services-Asheville ANALYTE QUALIFIERS J(D6) Estimated Value.The relative percent difference(RPD)between the sample and sample duplicate exceeded laboratory control limits. REPORT OF LABORATORY ANALYSIS This report shall not be repredhood,except In WII, Date:031241201611:43 AM without the written consentof Paca Amlytical Services,Inc.. Pageflof11 ® /'\ Pace Analytical Services,Inc. 2225 . Riverside ir Asheville.NC 26804 asawpeileEam (828)254796 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project. Victor BabgoO Effluent Pace Project No.: 92290429 Analytical Lab ID Sample ID QC Batch Method QC Balch Analytical Method Batch 92290429001 Effluent-Grab SM 2540D WET143646 92290429001 Effluent-Grab SM 5210B VVET143686 SM 5210B WETI43888 92290429001 Effluent-Grab SM 9222D WET143853 REPORT OF LABORATORY ANALYSIS This report shall not he mpmdnm4,a vepl in full, Date:031241201611:43 AM witted the wnilen consent of Pace analytical Servcee.Inc. Page 9 of 11 Oocument N2me: Document Realseda8FEB2016 Sample Condition Upon RacelptfSCU P i fY aceAnaliflcal° Document No; Issuing Authority: F CHP ES-00P Pace Hunt r vlll c ality ONE Client Pa9e2of2fnr,em+. Np�is FW of : [//I pFD,edt� WO#; 92290429 Courier; ❑Fad Ex OP5 Otfie Iient ❑c .. 1111111111111111110 ier;commercial ❑Pace ,❑USPS 02200420 Custody.Seal Present? Yea o Scala)mac[? Yes ❑No i bate/matlals Pereon Examining camema LIB///- PackingMptertal: /❑Bubble Wrep []Bubble Begs ode [[]Other: { /P Thermometer: Rbun p55N:15$27398 s Type of ice) et ❑Bluo ❑Nona QSemplgs on k¢,cooling process hasp I� Correction FactoN 0.0°C. Cooler Temp Connected,•Ch .Biological Tissue Frozen? .❑Yes ❑No N/A Temp should be above freazln 6°C. i U50A Regulated Soil( A,water sample) Did samples orlgmeta In a quarantine zone within the United States CA,NY,or SC(check maps)? Did samples"IS inata from aforelgnsourm(Intarha y, 1 ❑Vas No Inc(uding He we and Puerto Piw)?dyes a i COMMENTS: t Chain of Custody Present? es No NA 1 P Chain ofCustod Filled out? es No °NA 2. Chain of CustodyRelinquished? II e NaNA 3. Sam ler Name and/or Signature on COC? 4es �Ne NA A. q Samples Arrived within Hold Time? as ❑No ON(A S. ` Short Held Time Analals <T2 hr? s • No ❑NA 6. li. Rush Turd Around Time Requested? .. Yes 0INA 7.. Sufficlen"olumel as ❑No N A 8. I. Correct Containers Used? es (:lNo t]N(A S. -Pace Containers Used? a No. _ON/A I Contends Intact? es Ne N A: 0. i'.. Filtered Want.Received for Dissolved Tests?. vea No A 31 Noto if sediment isvls161e In the dissolved container I. Sample Labels Match COC? es ONO t7N/A 12. -Includes Date/Time/ID/Anal sit Matrix: All containers needing acid/base preservation have been 13. checked? [?Yes ONO N/A All containers needing preservation ate found to be In compliance with EPA recommendation? (HNO3,HzSO4,HCk2;NaOH>9 Sulfide,NaOH512 Cyanide) OYas ❑tip N( F.xceptlo(ts VOA,Cations,TOO,Oil and Brute, DR0/8015 Water OCCUR Yds No 'WA Sam ]as checked fordechloNnatlon =ves Na 30. Heads aceln VOAVlals >S.6mm? ..ves [IN. S. Trip Blank Present? ❑Yes f]No p 16, Trip Blank Custody Seals Present? Ely., ONO N/A Pace Trip Blank Lot g(if urchased: CLIENT NOTIFIGiTION/RE50LUTIbN Floid Date Required? ❑Yes ONO Person Contacted: Date/Time; Commems/Resolutlo a // I I 'Project Manager SCURF Review: Date: .3117 IY Project Manager SRF Review: Data: �� Note: Wnenaverthere lsadlsirepancyaif"" 9 North Carolina compliance samples,a Copyof this fmmwiil be sect th Nbrh Carolina DEHNP CettiRtatian ONire Q.e, Out of hold,incormotpreservative,nat of temp,incorrect ofitalha(s) Page 10(Lof s 1 5 +� v ac U a w N ITEM# r g� € 5 yT5 6a. ^� MATRIX cope dwvwwae.m ee) .E �. SAMP4E11E (6-OMB C•GGMP) u u r , v o g s BgMPLETEMP AT gOLLECi1GN r„ C NOF CONTAINERS S S Inn N (\ lh1 llnpreeervetl .�,� F Hz30. y h HCI 5 D NaOH Nez6z0a h Melhen6l Other `N � ' �Analyels TasC► wx� ,. � � m5 &� o m $ To.PG°G \- 2 F q Residual Chlorine(YIN) b fae IXlN) ( _1 -1 9 9eeICueWJY . . . �. o Fj. R (YIN) let / A ' kq�d A qsMe .� 41 .-J se r'lm Inner �i D Peg 11 of 11 + 'I. Sep.27.2011 12:17 PM K;'1A. 82S25, 70 PAGE. 1/ 2 • PO Box 7565 � a NC 2 8802 F T!5 Phone: (828)350-9364 Pa.: (829)3509368 qq aamronmontal`Ruaingsie l.ns,me' Certificate of Analysis Project name: Victor Babson Project number: 110913.500 Collection date: 15Sep-11 Date received: I5-S¢p-11 Sample identification: Effluent-Grab Sample number: 87495 Parameter Method Result RL Units A„e�y„ed Analyst Footnotes BOD,5 day SM 5210 B 2.9 2.0 mg/[. is-s.r.0 CD) Solids,Total Suspended SM 2540D 7.2 5.0 mg/L is-ws.n CDJ Bacteria,Fecal C9liform SM 9222 D 76 1 wbmpne Is-a 11 MHF Footnotes: RL=Ruporting Limit. Valuca arc reported down to the Reporting Limit only. Dat6,.Aowcd: Mal. NC Certification Number- 600 Data reviewed by: Kelley E.Keenan SC Cerllfcation Number: 99053 Signature: n%1/yc- NC Drinking Water Certification Number: 37786 This report shood not beteprodined,extolinits entirety,witout Mew .r-nne trisn,in,rinnadl lenina a.Vana,Inc. Thp rorap In this onpurt mtM only t0 aW 9amplu sub niNd for analysis. I�86E R North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary SURFACE WATER,PROTECTION SECTION August 26, 2011 Mr. Victor Babaoff 308 Secretariat Lane Fairview, NC 28730 SUBJECT: Compliance Evaluation Inspection Single Family Residence Wastewater Treatment System Permit No: NCG550475 Buncombe County Dear Mr. Babaoff: Enclosed please find a copy of the Compliance Evaluation Inspection form from the inspection conducted on August 10, 2011. The facility was found to be in compliance with permit NCG550475. Please refer to the enclosed inspection report for additional observations and comments. If you or your staff should have any questions, please call me at 828-296-4662. Sincerely, Wanda P. Frazier Environmental Specialist Enclosure cc: Central Files Asheville Files S:\SWP\Buncombe\Wastewater\General\NCG55 Single Family Residence\550475 victor BabBoff\CEI 8,10-11.doc SURFACE WATER PROTECTION—ASHEVILLE REGIONAL OFFICE Location:2090 U.S. Highway 70,Swannanoa, NC 28778 N'O�e'rhCarOlina Phone: 828-296-0500 Fax: 828-299-7043 Customer Service: 1-877-623-6748 �/Vitmally Internet:www.ncwateroualitv.org United States Eaviranmenoel Protection g9ency Form Approved. EPA w'ashington,nC.20450 OMB No 2040.0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding(i.e., PCS) Transaction Code NUDES yamo/day Inspection Type Inspector Fac Type 1 Iwl 2LJ 31 NCG550475 11 121 11/08/10 I17 16Lj 19LsJ 20 I R l l211 1 1 1 Jill Jill 1 1 1 1 11 1 1 1 1 1 l l l l l l l l l l l ls Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 OA -----------------Reservetl----------- 671 1.0 _j 69 701 v I 711 I 721 N I 731 1 1 74 75 I I I I I 190 LJ Section B: Facility Data LJ L1J Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also Include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 308 Secretariat Lane 01:15 PM 11/08/10 07/08/01 308 Secretariat L. Edt-Par ate Permit Expiration Data Fairview NC 28730 01:30 PM 11/08/10 12/07/31 Name(s)of Onsite Representative(s)lfitles(s)/Phone and Fax Number(.) Other Facility Data Name,Address of Responsible Offcial/fille/Phone and Fax Number Victor aabaoff 308 Secretariat Ln Fairview NC C.m.,:Ied § No28730//828-254- Section C: Areas Evaluated During Intal e areas evaluated) Permit 0 Operations&Maintenance 0 Facility Site Review 0 EfBuentlReceiving Waters Section D: Summary of Finding/Comments Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(.)and Signatures)of Inspector(s) Agency/Offioe/Phone and Fax Numbers Date Wanda PPFrazier ASO WQ//828-296-4500 Ext4662/ LVGb 0l l( ,L Gl TLC ';�D // Signature of Management O A Reviewer Agency/Office/Phone and Fax Num era Date o- l�i✓Q- P 8-z �—zc 1t EPA Farm 3560-3(Rev 9-94)Previous editions are obsolete. Page# 1 NPDES yr/mo/day Inspection Type (cont.) 1 31 NCG550495 j11 12I 11/0a/10 I17 18 UC Section D: Summary of Finding/Comments(Attach additional llJsheets of narrative and checklists as necessary) Authorization to Construct was issued:6-7-1989 The wastewater treatment system consists of: permitted flow of 480 gallons per day; 1200 gallon septic tank; �. 522 square feet of subsurface sand filter(87 feet in length x 6 feet wide); dual tablet chlorinator; 130 gallon chlorine contact chamber cascade aerator; and discharge to an unnamed tributary to Reed Creek(Spivey Lake) in the French Broad River Basin. sub-basin: 04-03-02 Inspection Summary and Recommendations: The chlorinator is located on the left side of the house in the back yard, behind a fence and is covered by a square concrete cover. The following are permit required monitoring and /or analyses.Analyses are required to be performed by a NC certified lab. Flow—monitor annually—estimate BOD—analyze grab sample annually limits: 30 mg/I monthly average/45 mg/I daily maximum TSS—analyze grab sample annually limits: 30 mg/I monthly average/45 mg/I daily maximum Fecal coliform—analyze grab sample annually limits: 200 colonies/100 ml monthly average 1400 colonies/100 ml daily maximum Total Residual Chlorine—analyze grab sample on-site within 15 minutes of collection limit: 17 ug/I Please contact a NC certified laboratory to perform the testing. Please maintain the sample results for 3 years and have them available at the next DWQ inspection. I4 Page# 2 I Permit: NGG550475 Owner-Facility: 308 secretariat Lane Inspection Date: 08/10/2011 Inspection Type: Compliance Evaluation Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new application? ❑ 0 ■ Cl Is the facility as described in the permit? ■ 0 0 0 #Are there any special conditions for the permit? Cl ■ 0 0 Is access to the plant site restricted to the general public? ■ 0 0 ❑ Is the inspector granted access to all areas for inspection? ■ Cl 0 ❑ Comment: Operations& Maintenance Yea No NA NE Is the plant generally clean with acceptable housekeeping? ■ 0 0 Cl Does the facility analyze process control parameters,for ex: MLSS, MCRT,Settleable Solids,pH, DO,Sludge 0 0 ■ 0 Judge, and other that are applicable? Comment: The grass in the yard, over the subsurface sand filter is very well maintained. Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ■ 0 0 0 Are the receiving water free of foam other than trace amounts and other debris? ■ 0 0 Cl If effluent (diffuser pipes are required) are they operating properly? 0 0 i ❑ Comment: Page# 3 R-G-31-2005 09:OG FROM:WIC TIRE INC lu P597043 P.1 _ J�O�wnrF9vc M4Teal F.E.s"Z.Gavamor Vmera e.Rowan Resources Noah CarolNa DepaNrmnl ufEmlmnmenl and Natural Resourmc (i Yt' Aran W.NAM.R.P.E.Dh naar owlalan of Water Dualny Aahevaa RaafnnalOm[a SURFACE WATER PROTECTION July 22,2005 CERTIFIED MAIL .. RETURN RECEIPT REQUESTED Toazzaba aaos zeaa zaoz Mr. Victor Babaoff c/o WNC Tire Company Post Office Box 6069 Asheville, North Carolina 20816 Subject: NOTICE OF VIOLATION NOV-2005-PC-0175 Compliance Evaluation Inspection Babaoff Victor-Residence Permit No. NCG650475 Dear Mr. Babaoff. Buncombe County g131 d Enclosed please find a copy of the Inspection Reportfrom the Inspection conducted JUly21, 2005. Mr. Larry Frost of the Asheville Regional Office conducted the Compliance Evaluation Inspection. The treatment facility was found to be in violation of Permit NCG560475 for the following: Inspection Area Compliance Issue ry/ Tablet Chlorinator Failure to Maintain Chlorine Contact Chamber Failure to Maintain Please refer to the enclosed Inspection Report for any dditional observation and comments. To prevent further action, carefully review these violations and deficiencies and respond in writing to this office within fifteen (15)working day of receipt of this letter. You should address the causes of noncompliance and all actions taken to prevent the recurrence of similar situations. If you should have any questions, please do not hesitate to contact Mr. Frost at 8282964500. Sincerely, Roger C. Edwards, Regional Supervisor Surface Water Protection Attachment cc: WO Central Files w/attachment Enforcement w/attachment zn90 US.HlShw[y'la,Sxannemo,N.C.29T38 Tdephoa:8242A5-0 PAX: B3BR6p.'lae3 ��', AVG 31 2005 WATER QUALITY SLCTION ASHEVIl LE PHGIONAL O_GIL`E A FWATF9 MicheelF Easley,Governor �� Q ' i� ,� HWlllp(nG RossJc,Secretary „O G• � North Carolina Dej.. dent of Environment and NaW�al Resources � �r Alan W KlimeN,P.E.-0irector � ..., y Dimsion of Water Quality P < �' Asheville Regional Office SURFACE WATER PROTECTION July 22, 2005 CERTIFIED MAIL RETURN RECEIPT REQUESTED 7002 2410 0006 2900 3905 Mr. Victor Babaoff c/o WNC Tire Company Post Office Box 6069 Asheville, North Carolina 28816 Subject: NOTICE OF VIOLATION NOV-2005-PC-0175 Compliance Evaluation Inspection Babaoff Victor- Residence Permit No. NCG550475 Buncombe County Dear Mr. Babaoff: Enclosed please find a copy of the Inspection Report from the inspection conducted July 21, 2005. Mr. Larry Frost of the Asheville Regional Office conducted the Compliance Evaluation Inspection. The treatment facility was found to be in violation of Permit NCG550475 for the following: Inspection Area Compliance Issue Tablet Chlorinator Failure to Maintain Chlorine Contact Chamber Failure to Maintain Please refer to the enclosed Inspection Report for any additional observation and comments To prevent further action, carefully review these violations and deficiencies and respond in Writing to this office within fifteen (15) working day of receipt of this letter. You should address the causes of noncompliance and all actions taken to prevent the recurrence of similar situations. If you should have any questions, please do not hesitate to contact Mr. Frost at 828/296-4500. Sincerely, // Roger C. Edwards, Regional Supervisor Surface Water Protection Attachment cc: WQ Central Files w/attachment Enforcement w/ attachment 2090 U.S.Highway 70,Swannanoa,N.C.23772 Telephone:828/296-4500 PAX: 82M99-7043 Customer Service:977/623-6749 Npp'rt'hCamlina �VRt2r2 ' ( / United States EuvlmnmehW Protection Agency EPAwasningmn,o c.zoaeo Form Approved. OMB No.2040-0057 ater Com liance Ins action Re O Approval expires 0-31-98 Section A: National Data System Coding(i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 2 1,1 31 NCG550475 11 121 05109121 117 181r IJ1 19L'] L 2gi LJ Re I marks J 21IIIIIIIIIIII Jill IIIIIIIIIIIIIII Jill IIIIIIIIIIIss Inspection Work Days Facility Self-Monitoring Evaluation Rating B1 CA -Reserved------------------ 67I 69 70 U 71 u 72 U 73 W 74 75I I I I 89 Section B: Facility Data Name and Location of Facility Inspected(For Industrial Users discharging to POTW,also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 02/08/U1 0120 PM 05/07/21 Babaoff V.ictOt- ae5i.denw 308 Secretariat an Exit Time/Date Permit Expiration Date Paim,,ew NC 28130 01:35 PM 05/07/21 07/07/31 Names)of Onsite Representative(s)/Dtles(s)/Phone and Fax Numbers) Other Facility Data 1 Name,Address of Responsible Official/Title/Phone and Fax Number Contacted vi.cCni: Babaoff,308 Secretariat Ln Fairview NC A6130//704-628-4542/8282549778 No Section C: Areas Evaluated During Inspection(Check only those areas evaluated) Operations&Maintenance 0 Facility Site Review Section 0: Summary of Finding/Comments Attach additional sheets of narrative and checklists as necessary) (See attachment summary) i Names)and Signature(s)of Inspectors) Agency/ORcwPhone and Fax Numbers Date �lidCry Ftoat �V /� 9Fo 414//028-296-9500 F,xt.4650/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date rj--� Roger C rldwa[de �r /, Y 828-296-4500 Sat.4556/ 7 EPA Form 3560-3(Rev 9-94)Previous editions are obsolete. NPDEB yr/molday Inspecllon Type 1 3� NCGh5U4i5 �11 12L o5/a,, t] 181�I Section D: Summary of Finding/Comments(Attach additional sheets of narrative and checklists as necessary) Th, facility is not being maintained a., required by the permit. Measures 'must be taken immediately Co being th1h fleil.ty Into Pecmlt compliance. n ' t Operations$Ma nfenanere Yes, No NA NE Is the plant generally clean with acceptable housekeeping? ❑ ■ 0 ❑ Cods the facility analyze process control parameters,for ex:MISS,MCRT,Set leable Solids,pH,CO,Sludge Judge, 0 and other that are applicable? Comment The facility is overgrown and appears to have not been maintained recently. Disinfecfon-Tahlef Yes No NA NE Are tablet chlorinators operational? ❑ ■ O ❑ Are the tablets the proper Size and type? ❑ 0 Number of tubes in use? 0 Is the level of chlorine residual acceptable? ❑ 0 O Is the contact chamber free of growth,or sludge buildup? ❑ ❑ ❑ Is there chlorine residual prior to de-chlorination? ❑ 0 0 ■ Comment:Covers are overgrown and chlorinator is flooded, NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Michael F. Easley, Governor William G. Ross,Jr., Secretary Alan W. Klimek, P.E., Director SURFACE WATER PROTECTION SECTION December 10, 2004 Victor Babaoff Trustee c/o WNC Tire Company Post Office Box 6069 r 7/ Asheville, North Carolina 28816 Subject: Request for Telephone Contact NPDES Permit Number NCG550475 308 Secretariat Lane Residence Buncombe County Dear Owner: This letter is to request that you contact me within the next few days at this office; telephone (828) 296-4500 (8:00 A.M. to 4:30 P.M.) so that I may complete my investigation of a reported sewage odor in the stream possibly from your residential property on Secretariat Lane. If my information is correct, and it is your wastewater system causing the problems, I would request that you correct the problem and thereby cause this problem to cease. I would hope that this could be completed with little difficulty. Please understand that such issues with your system may constitute violations of your NPDES Permit and are enforceable under provisions of NCGS 143-215.6A as administered by this Agency. You are requested to take all action necessary and proper to correct the problem. Thank you for your attention to this matter. I lock forward to hearing from you at your earliest convenience. Sincerely, La I En ronmental Chemist xc: Buncombe County Health Department-35 Woodfin Drive,Asheville, North Carolina 28801 Asheville Regional Office nc 2090 U.S.Highway 70,Swannanoa,North Carolina 28778 Phone: 828-296-4500I FAX: 828-299-7043/Internet h2o.enc state,naus OrthCarOhna An Equal Oppommily/Affirmative Action Employer—50%Rai 0%Post Consumer Paper fall!" r� y aw0 State of North Carolina Department of Environment, Health, and Natural Resources Asheville Regional Office James G. Martin, Governor Ann B. Orr William W. Cobey, Jr., Secretary Regional Manager DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION April 2, 1992 Mr. Victor Babaoff Post Office 6069 Asheville, North Carolina 28816 Subject: Compliance Evaluation Inspection Status: In Compliance Victor Babaoff Residence YIIIZ20`a�o S ermit Number NCO074098 County Dear Mr. Babaoff: A Compliance Evaluation Inspecas conducted March 20, 1992, of the septic tank/subsurface sandfilter trench serving your residence. Since the facility grounds and the receiving stream indicated no problems, the wastewater treatment facility appears to be operating properly and is, therefore, considered to be in compliance with its NPDES Permit. If, in the future, the residence is sold, please inform the new owners that they will need to apply for a new permit. NPDES Permits are not transferable. If you should have any questions, please contact me at 704-251-6208. Sincerely yours, Linda Wiggs Environmental Technician Enclosure xc: Dan Ahern, EPA Inrerchange Oulldmp, 59 Woodfln Place, Asheville, NC_28801 •Telephone 70 2516208 An hPnnl Op�nurnlry Afflrmalve Action Lnploycr el s n.,a,.e.ee ai ,o�eaee naaew � Forte App,­e A /aasningioe.Il C.3Oa60 I OMB No.2O4O-0003 �eEPA NPDES Compliance Inspection Report AppmvalExpires731-S6 Section A: National Data System Coding r e section Code NPOE S yr/mo/day Inspe�c�tppio�n Type Ins actor Fac Type IVj �J jNIc1o1o114 o19 111 1�98101,9Ia101 17 11tv1 ICJ 2c� -" Remarks IIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIIII 6fi Reserved Facility Evaluation Rating RI d4 ------------------Reserved -------------- 6�J Sg 74 - 71u 72u 7aJ ' '74 7q 1 1 1 1 I l so Section S:Facility Data Jame and`yocation o Facility Inspected riury Time AM PM Permit HectiveD vi(AO'(- Qa/�9e-0� //: . 3/ N.Ny -14.p xit Time/D permitnpiretian ate . jo ,3 am s ot un-Sue Reports mauve(s) Title(s) Phone No(s) Jame.Address of Re onsible 0 i lal Title V i(rtvti L Q� 66Oq Phone No. �b)Lao ` Contacted Y' 6 ✓ =�/ ❑ Yes No Section C:Areas Evaluated During Inspection (S=Satisfactory,M=Marginal.U=Unsatisfactory,N a Not Evaluated) Permit I PJ I Flow Measurement Pretreatment Operations&Maintenance Records/Reports Laboratory Compliance Schedules Sludge Disposal �- Facility Site Review M I EH them/Receiving Waters Sell-Monitoring Program Other: Section D:Summery of Findings/Comments/Attach additional sheets if necessary/ N6 Ira M�Wi �Fs ���u'6- w� � /VO� Name(s)a Si&wn.rels)of Inspectors) Agency/Offic /TeI ph.n ! Data WI �E� JQT -70Y-25/' 3 L^ S J e Signam Re sewer Agency/Office Date I f 2" Ragulemry Office Use on Action Taken Date Cum liance Status LJ N empliance Com liance State of North Carolina Department of Environment, Health, and Natural Resources Asheville Regional Office James G. Martin, Governor Ann B. Orr William W. Cobey, Jr., Secretary Regional Manager DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION September 8, 1991 Mr. Victor Babaoff Post Office 6069 Asheville, North Carolina 28816 . Subject: Compliance Evaluation Inspection Status: In Compliance NPDES Permit Number NCO074098 Buncombe County Dear Mr. Babaoff: A Compliance Evaluation Inspecti was conducted August 14, 1991, of,-,the septic tank/ subsurface sandfilter trench serving your residence. Since the facility grounds and the receiving stream indicated no problems, the wastewater treatment facility appears to be operating properly and is, therefore, considered to be in compliance with its NPDES permit. If, in. the future, the residence is sold, please inform the new owners that they will need to apply for a new permit. NPDES permits are not transferable. If you should have any questions, please contact me at 704-251-6208. Sincere�}r y u (JJ Kerry S . Becker Environmental Technician cc: Dan Ahern, EPA ksb Interchange Building, 59 Woodfin Place, Asheville, NC 28801 •Telephone�2516208 An Equal Opponuniry AHirmafive Acton Employer r menial miettlon Agency Form Approved ^ • _.,na 1B1WesFin9�on.O.C20460 a®EPA NPDES Com fiance Inspection Report OMBvalE-PO-0006 P P P Approval Expires 7-31-85 Section A: National Data System Coding Trans ction Code NPDES yr/mo/day Inspection Type Inspector Fat,Type � J _1010171�1019181 1 1 / 0 ( 17 1 _g 1� 2CL2 Remarks 11111111111111111111111111111111111111111111111 Reserved Facility Evaluation Rating BI O.A -----------------Reserved---------------- 66 6A 1 1 I69 7c_3J 71U ] ICJ ] I�j]a ]s{ I IBo Section B:Facility Data Name and Location of Facility Inspected FEm,',, Permit Effective Date / I n TtePermit Expiration Date (2 Time❑ AM PM p7f - 3 - 3 ame)s o n-Site Represen[ative(s) Titlelsl Phone No(s) �Name,Address of Responsible Official Title y I G 4,(, 's Q �' 0p4 QL(f Sob to C)6q Phone No. lacletl J2 iC • 'Z O - 2SY/- ( Yes❑ No Section C:Areas Evaluated During Inspection IS=Satisfactory,M=Marginal,U=Unsatisfactory.N=Not Evaluated) 51 Permit Flow Measurement Pretreatment Operations&Maintenance 5 Fl-cords/Reports Laboratory Compliance Schedules Sludge Disposal Facility Site Review EHluent/Receliving Waters Self-Monitoring Program Other. Jj //Section D:Summary of.Findi/ngs/Comments(Anttach additional sheets i/rrecesse/ryJn FOP ll5 d LP e n $Y Conn— w l C X e d /F o afaw l b� Dti � 14Jo� a � rN Fis em s ; � O h c �Q u Names)and Signature(.)of Inspector(s) Agency/Office/Telephone Data � . E Promo 70 - zsl- lp2ad lg Signs re of Reviewer AgencFy/Office Date ,v RaBuletory ffice Use On Action Taken Date Compliance Status ❑ N compliance om liance Arc, ACO- 9 / FLvrr 1� c IMP RTANT MESSAGE TO- . . / r`J r DATE ���Z'3 A.M. TIME �u WH LE YOU WERE OUi OF Area.Code f A Exchange a- TELEPHONED EASE CALL CALLED TO SEE YOU WILL CALL AGAIN WANTS TO SEE YOU URGENT !. RETURNED YOUR CALL Ida Operator o vvv It, cm., State of North Carolina Department of Natural Resources and Community Development Asheville Regional Office James G. Martin, Governor Ann B. Orr William W. Cobey,Jr., Secretary Regional Manager DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION September 15, 1989 Mr. Victor Babaoff P.O. Box 6069 o 0 Asheville, North Carolina 28816 Subject: Compliance Evaluation Inspection . Victor Babaoff Residence E vDco Permit #NC0074098 BBu/ficombe County Dear Mr. . Babaoff: A Compliance Inspection. was conducted September 11, 1989, of the - wastewater treatment facility serving your residence at 308 Secretariat Lane in Fairview Downs Subdivision. At the time of the inspection, the house was still under construction, however, you said that some of the work crews were using the bathroom facilities in the house. It would be best if chlorine tablets were added to the chlorinator at this time in the event the wastewater facility ehould begin to discharge treated wastewater to the stream. These tablets can be purchased from: Ticar Chemical Corp. Jet-Chlor Brevard Road 750 Alpha Drive Asheville, North Carolina 28806 Cleveland, Ohio 44143 704-667-0161 216-461-2000 Even though .French drains have been placed around the sand filter beds to remove excess groundwater there is . still a fair amount of groundwater issuing from the effluent pipe. If enough groundwater inundates the sand filter beds and is not remedied by. the French drains, the degree of treatment provided by the sand filter beds may be reduced. This can best be determined at a later date after the house has been occupied and the abnormally heavy seasonal rainfall has subsided. Interchange Building, D% dBu Place, Ashrvil[e;N.C.28M] •Telephone�251d 08 During our discussion you expressed any interest in the development of the three adjacent lots that you own with the idea of installing additional- discharging wastewater treatment systems such as the one installed at 308 Secretariat Lane. The waste load allocation conducted for the stream to which they would discharge has determined that the assimilative capacity of the stream to accept treated wastewater has been reached. For any stream which has reached its assimilative capacity, no additional discharges are allowed. Since this is the case with the stream you propose to discharge to, no permits can be issued for the construction of additional discharging wastewater treatment facilities. If you should have any questions, please call either Max Haner or me at 704-251-6208. Sincerely �� yours, vrcr�- KerryUS. Becker o a Environmental Technician cc:Dan Ahern, EPA ksb United tates Environmental Protecnon Agency Form Approved /1 Wsshingmn,D.C.20080 �yEPA NPDES Com fiance Ins action Re ort OMeNo2040-0003 p p p Approval Expires 7-31-85 Section A:National Data System Coding Transaction Code NPDES yr101 / ay Inspection Type lInspector 2F�ype /� �J �nI G o O�yLD1Q ,� 11 , y Ei ALII _�4ILL2 Remarks � III� 111111111111IIIIII11111111111111111 111111511E Reserved Facility Evaluation Rating 81 Dq -----------------Reserved----------------- 6� 1 1 59 7CL5j 71 , j 7JLD 74 5 so Section 8: Facility Data Name and Le etioj� of 7Fee I y In road RAO ry Time Permit Effective Date (yl e.-/M '? G1# T'T /T 25/N2n da AM PM I P� 34SScee�aM/4f iFNh Time/Date Pena EzpaationDate F /Kv/IF ow vs w /v/s LD e~� �, &YOP11 _5jol 30 3 ems s of On-Si a Rlepresentativels Title(s) PhIme Noud Narp,Adores s.}� esponsible,slficial Title lei e In x (A s fd' /'D V, (,sp y/ �0 Ad6�9/�A' // Phone No. ��[IIContacted a2 1Y O - -� - }'rYes❑ No Section C:Areas Evaluated During Inspection IS=Satisfactory,M=Marginal,U=Unsatisfactory,N=Not Evaluated) Permit n/ Flow Measurement H Pretreatment Operations&Maintenance Records/Reports om Laboratory Cpliance Schedules Sludge Disposal Facility Site Review Effluent/Receiving Waters Self-Monitoring Program Other: Section D:Summary of Findings/Comments(Attach additional sheets i/necessary) l v�rm—/� �m✓eur 4 Luax L'ta ✓S 4ce/ N/Oq `L -hW C i /{"/f.P.a . /'(•f` /llR� AC d is Ps/!�.✓! CLt t/JYG/NN�"GM p7fvw u a eti S / rJ /ke- 2C ;� -i at e.* Q�of '�i�C ,twGv�sle.v. Names)a nd q igilature(sl of Inspector(s) Agency/Offixt/Telephone DateRd / d -25-//a 2OF O`. Signature of Reviewer Agency/Office Date Regulatory Office Use Only Action Taken Data Compliance Status ❑ Noncompliance INSTRUCTIONS Section A: National Data System Coding (i.e., P.CS) Column 1 :Transaction Code: Use N, C,or D for New,Change,or Delete.All inspections will benew unless there is an error in the data entered. Columns 3-11 : NPDES Permit No. Enter the facility's NPDES permit number. (Use the Remarks columns to record the State permit number, if necessary.) Columns 12-17: Inspection Date. Insert the date entry was made into the facility. Use the year/month/day format (e.g., 82/06/30 =June 30, 1982). Column 18: Inspection Type. Use one of the codes listed below to describe the type of inspection: A — Performance Audit E - Corps of Engrs Inspection S — Compliance Sampling B — Biomonitoring L— Enforcement Case Support X — Toxic Sampling C — Compliance Evaluation P — Pretreatment D — Diagnostic R — Reconnaissance Inspection Column 19: Inspector Code. Use one of the codes listed below to describe the lead agency in the inspection. C — Contractor or Other Inspectors(Specify in N — NEIC Inspectors Remarks columns) R — EPA Regional Inspector E — Corps of Engineers S — State Inspector J —Joint EPA/State Inspectors—EPA lead T'—Joint State/EPA Inspectors—State lead Column 20: Facility Type. Use one of the codes below to describe the facility. 1 — Municipal. Publicly Owned Treatment Works (POTWs) with 1972 Standard Industrial Code (SIC) 4952. 2 — Industrial. Other than municipal, agricultural, and Federal facilities. 3 — Agricultural. Facilities classified with 1972 SIC 0111 to 0971. 4 — Federal. Facilities identified as Federal by the EPA Regional Office. . Columns 21-66: Remarks.These columns are reserved for remarks atthe discretion of the Region. Column 70: Facility Evaluation Rating. Use information gathered during the inspection(regardless of inspection type)to evaluate the quality of the facility self-monitoring program. Gradethe program using a scale of 1 to 5 with a score of 5 being used forvery reliable self-monitoring programs, 3 being satisfactory, and 1 being used for very unreliable programs. Column 71 : Biomonitoring Information. Enter D for static testing. Enter F for flowthrough testing. Enter N for no biomonitoring. Column 72: Quality Assurance Data Inspection. Enter Q if the inspection was conducted as followup on quality assurance sample results. Enter N otherwise. . Columns 73-80: These columns are reserved for regionally defined information. Section B: Facility Data This section is self-explanatory. Section C: Areas Evaluated During Inspection Indicate findings IS, M, U, or N) in the appropriate box. Use Section D and additional sheets as necessary. Support the findings,as necessary, in a brief narrative report. Usethe headings given on the report form (e.g., Permit, Records/Reports) when discussing the areas evaluated during the inspection.The heading marked"Other" may include activities such as SPCC, BMP's,and multime- dia concerns. - Section D: Summary of Findings/Comments Briefly summarize the inspection findings. This summary should abstract the pertinent inspection findings,.not replace the narrative report. Reference -a list of attachments, such as completed. checklists taken from the NPDES Compliance Inspection Manuals and pretreatment guidance documents, including effluent data when sampling has been done. Use extra sheets necessary. ., State of North Carolina Department of Natural Resources and Community Development Asheville Regional Office James G. Martin, Governor Ann B. Orr William W. Cobey,Jr., Secretary Regional Manager DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION July 14, 1969 Mr. Michael Taylor C/O WNC Tire PO Box 6069 Asheville, N.C. 28816 Subject: Completion of Construction Septic Tank/Subsurface Sand Filter System NPDES Permit No. NC0074098 Victor Babaoff Residence Buncombe County, N.C. Dear Mr. Taylor: On July 14, 1989, I reviewed the construction of the septic . tank/subsurface sand filter system at subject property known as Victor Babaoff Residence, Lot 7i68, in Fairview Downs Subdivisions. It appears that the system has been installed in accordance with plans and specifications approved by the Division under NPDES Permit No. NC0074098. Therefore, the system should produce an effluent in compliance with terms and conditions of the permit. Should you wish to further discuss this matter, please contact me. Yours pruly, /� , , �J ' Max L. Haner Environmental Chemist cc: Forrest R. Westall Ann Freeman Interchange Building, 59 Woodfin Place, Asheville, N.C. 28WI 0 Telephone] 2516208 ' SENDER: 'o Complete items t endear 2 for additional servlcee. I also wish to receive the 'm sComplete Items 3,4a,and 4b. following services(for an N / "\yovr name and address an th wave of Als form so that we can(stern this same fee): . d apnsom this from to the front of the mallplece,or on the back if apace does net 1. 13 Addressee's Address Wnt.-Rmp.Recei rIp f d'crthe mall below Me made numbe,. 2. M Restricted Delive'y p hoses pier ry rqj The Rum Pleasant Wit ehowto whom 4lde lM1a a was dellvaretl and lM1e data � delivered. Consult postmaster for tee. ..•i. a 3.Adiele Addressed to: 7002 24100006 290O 39�7G E 41p.Service Type I ° ❑ Registered i A bedlfled ❑ Express Mall �/ " [3 Insured adRetumceipt Re for lryenchamdise [,COD o _ 7.Date of /'Oelive ^f° i �cc,�1 10 Fj¢ r p 5.Recei ad By: (Pdnt Name) B.Addressee's AddrPes(Qnly ii repuesfed { ru ( end lee is paid) ri. j be 6.signature-(Atl nt) i i X 7,7 PS Form 3811, December 1994 Domestic Return Racal