Loading...
HomeMy WebLinkAboutWQ0035364_Sewer Extension_20110425pF W ATFRQG State of North Carolina pt DENRa1Mfq0f Environment and Natural Resources �' 7 Division of Water Quality o APK 15 2011 FAST -TRACK APPLICATION PC%,(FTA 12/07 very) for GRAVITYPUMP STATIONS, AND FORCE MAINS (Pressure & Vacuum sewer systems are not to be included as part of this application package) INSTRUCTIONS: Indicate that you have included/addressed the following list of required application package items by checking the space provided next to each applicable item. Failure to submit all required items will lead to your application being returned as incomplete. Forms are available from the web site or by calling the Regional Office serving your county: http://h2o. enr state. nc. us/peres/Collection%20Systems/CollectionSystemApplications. html A. Application Form - Submit one original and one copy of the completed and appropriately executed application form. The application should include a project narrative describing the final build -out design (i.e. system and/or pump station to ultimately serve 500 homes, but flow for only 100 homes being requested now). For modifications, clearly explain the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information that has already been included in the original permit. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless you respond NO to Item B(13) Separate applications should be made for non-contiguous sewer systems JK B. Application Fee - Submit a check in the amount of $480 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). Checks shall be dated within 90 days of application submittal. ❑ C. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2)a of this application. ❑ D. Operational Agreements — Submit one original and two copies of a properly executed operational agreement, as per 15A NCAC 02T .0115, if the application is submitted by a private applicant and will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be sold to another entity. If the applicant is a home or property owner's association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF THE PROJECT MAY BE TURNED OVER TO A MUNICIPALITY UPON COMPLETION, FORM DEV 02/03 IS REQUIRED. E. Downstream Sewer, WWTF Capacity and Flow Tracking/Acceptance — FORM FTSE 10/07 (Flow Tracking/Acceptance for Sewer Extension Permit Applications) is required with every application. The applicant (and owners of downstream sewers, pump stations and/or treatment facilities submitting FORM FTSE-10/07) certifies that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving treatment plant, and that the flow from this project will not cause capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving wastewater treatment plant. Where the applicant is not the owner of the downstream sewer, submit two copies of FORM FTSE 10/07 from the owner of the downstream sewer and owner of the WWTF, if different. The flow acceptance indicated in FORM FTSE-10/07 must not expire prior to permit issuance and must be dated less than one year prior to the application date. Submittal of this application and FORM FTSE-10/07 indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). Intergovernmental agreements or other contracts will not be accepted in lieu of project -specific FTSE 10/07. F Map — Submit an 8.5-inch by 11-inch COLOR copy of a USGS Topographic Map of sufficient scale to identify the entire project area and the closest surface waters. Each map or maps must show the location of the sewer line and pump stations and be of reproducible quality. Include a street level map showing the downstream connection point, and the permit number for the downstream sewer, if known. FTA 12/07 ❑ G. Stream Classifications — Watershed Classification Attachment (Form WSCAS-12/07) If any portion of the sewer system project is within 100 feet of any surface water or wetlands, the Watershed Classification Attachment may. need to be completed. A variance must be requested for encroachment within required setbacks or buffers pursuant to 2T .0305 (f) and be indicated in Item B-13 with supporting documentation/justification provided. ❑ H Environmental Assessments — If this project is subject to an Environmental Assessment (EA) [15A NCAC 01C], this application cannot be used. Send the project application on the most current version of Form PSFMGSA to the Design Management Unit, 1633 Mail Service Center, Raleigh, NC 27699-1633. Applications cannot be accepted until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. ❑ I. Flow Direction — Many wastewater treatment systems are entering into agreements for regionalization efforts and emergency treatment capacity. Parts of the system are installed so that the wastewater flow can be directed to more than one treatment facility. If this is the case with this project, please indicate in 13(12) and give the permit number of the second treatment facility. 'Pl J. Certifications — Section C The application must be certified by both the applicant and the design engineer who is a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(lb). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC Chapter 2T, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. THE COMPLETED FTA 12/07 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $480 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE: REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Cherokee, Swannanoa, North Carolina 28778 Clay, Graham, Haywood, Henderson, Jackson, (828) 296-4500 Macon, Madison, McDowell, Mitchell, Polk, (828) 299-7043 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Hoke, Fayetteville, North Carolina 28301-5094 Montgomery, Moore, Robeson, Richmond, (910) 433-3300 Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue Alexander, Cabarrus, Catawba, Cleveland, Mooresville, North Carolina 28115 Gaston, Iredell, Lincoln, Mecklenburg, Rowan, (704) 663-1699 Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Franklin, Raleigh, North Carolina 27699-1628 Granville, Halifax, Johnston, Lee, Nash, (919) 791-4200 Northampton, Orange, Person, Vance, Wake, (919) 788-7159 Fax Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bete, Camden, Chowan, Craven, Washington, North Carolina 27889 Currituck, Dare, Gates, Greene, Hertford, Hyde, (252) 946-6481 Jones, Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, New Wilmington, North Carolina 28405 Hanover, Onslow, Pender (910) 796-7215 (910) 350-2004 Fax Winston-Salem Regional Office 585 Waughtown Street Alamance, Alleghany, Ashe, Caswell, Davidson, Winston-Salem, North Carolina 27107 Davie, Forsyth, Guilford, Rockingham, Randolph, (336) 771-5000 Stokes, Surry, Watauga, Wilkes, Yadkin (336) 771-4630 Fax For more information, please visit our web site at. h ttp://h2o. enr.state. nc. uslperes/Collection%2OSystemsICollectionSystemsHome. html or contact the Regional Office serving your county. FTA 12/07 USE THE TAB KEY TO MOVE FROM FIELD TO FIELDI Application Number: (to be completed by DWQ) 0X 1. Owner/Permittee: 1a. Moore C I ounty Public School Full Legal Name (company, municipality, HOA, utility, etc.) 0 1 b. Mr. John Hawthorne Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) 1c. The legal entity who will own this system is: ❑ Individual ❑ Federal ❑ Municipality Z State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify): 0 1d. 5277 US Hwy 15-501 1e. LL —Carthage Mailing Address City Z 1f. North Carolina 1g. 28327 Z State Zip Code 0 F— 1 h. 910-947-2976 1 i. I i. 'hawthorne ncmcs.or Telephone Facsimile E-mail V2. Project (Facility) Information: J 2a. Cameron Elementary School Pump Station & Force Main 2b. Moore IL I" Brief Project Name (permit will refer to this name) County Where Project is Located a 3. Contact Person: Q 3a. Clark Thomas, McGill Associates, PA Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 910-295-3159 3c. clark.thomas@mcgillengineers.com Phone Number E-mail 1. Project is Z New ❑ Modification (of an existing permit) If Modification, Permit No.: 2. Owner is Z Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Public Utility (Instruction C) ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction D) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Moore County Public Utility Z Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 0 ~Q 4a. Moore County Regional Water Pollution Control Plant 4b. NC 0037508 Name of WWTF WWTF Permit No. 5a. Moore County 5b. 8-inch ® Gravity 5c. Unknown Owner of Downstream Sewer Receiving Sewer Size ❑ Force Main Permit # of Downstream Sewer (Instruction E­) 0 LL 6. The origin of this wastewater is (check all that apply): ❑ Residential Subdivision ❑ Retail (Stores, shopping centers) 100 % Domestic/Commercial ❑ Apartments/Condominiums ❑ Institution /o o Industrial (attach El Mobile Home Park El Hospital Z School ❑ Church description.) aEl Restaurant El Nursing Home (RO: contact your Regional Office ❑ Office ❑ Other (specify): sP eci Pretreatment staff) m % Other (specify): 7. Volume of wastewater to be allocated or permitted for this particular project: 5,400 gallons per day 'Do not include future flows or previously permitted allocations 8. If the permitted flow is zero, indicate why: ❑ Pump Station, Outfall or Interceptor Line where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected (see 15A NCAC 02T .0303 to determine if a permit is required) FTA 12/07 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2T .0114 fc the value in Item B(7) AND/OR the design flow for line or pump station sizing if a reduced or zero flow is being requested in Item B(7). Values other than that in 15A NCAC 2T .0114 (b) and (c) must be supported with actual water or wastewater usl data in accordance with 15A NCAC 2T .0114 (f . 360 Students x 15 gallons per student = 5,400 gallons a day. The schools full capacity = 360 students. 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) New Gravity or Additional Force Main 8-inch 750 Gravity 4-inch 24,700 Force Main in 11. Summary of Pump Stations w/ associated Force Mains to be Permitted (attach additional sheets as necessary) W Z Pump Station Location ID Cameron Elementary Pump Station (self chosen - as shown on plans/map for Design Flow Op Point Power ReliabilityOption Z (MGD) GPM @TDH 1 -permanent generator w/ATS; Force Main Size Force Main Length O 2 - portable generator w/MTS U `-' 0.005 80 gpm@ 50' 1-permanent Gen WATS 4-inch 24,700-ft Z O Pump Station Location ID N/A (self chosen - as shown on plans/map for Design Flow (MGD) Operational Point Power Reliability Option 1 0 GPM @TDH -permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS LL H WPump Station Location ID N/A (self chosen - as shown on plans/map for I.L Design Flow O pGPM eration ant Power Reliability Option m (MGD) @ TDH 1 -permanent generator w/ATS; Force Main Size Force Main Length 2 - portable generator w/MTS 12. Will the wastewater flow in the proposed sewer lines or pump stations be able to be directed to another treatment facility? ❑ Yes ® No If Yes, permit number of 2"d treatment facility (RO - if "yes" to B,12 please contact the Central Office PERCS Unit) 13. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC Chapter 2T as applicable? ® Yes ❑ No If No, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION FTA 12/07 14. Have the following permits/certifications been submitted for approval for the system or project to be served? 0) 0 H Q LL F- W U A Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No ® N/A Sedimentation and Erosion Control Plan? ® Yes ❑ No ❑ N/A Stormwater? El Yes ❑ No 5d N/A 15. Does this project include any high priority lines, (see 15A NCAC 02T .0402 (2)) involve aerial lines, siphons, or interference manholes)? These lines will be considered high priority and must be checked once every six months Check if Yes: ❑ and provide details N/A 1. Owner/Permittee's Certification: (Signature of Signing Official and Project Name) 1, John Hawthorne . attest that this application for Cameron Elementary School Pump Station & Force Main has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being retumed as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or ce ication in any application shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as w 11 a,s civil penayes up to;25, 000 per violation. Si g Official Signature Date EN6`INEERING DESIGN DOCUMENTS MUST BE COMPLETED PRIOR TO SUBMITTAL OF THIS APPLICATION. THESE DOCUMENTS MUST INCLUDE PLAN AND PROFILE OF SEWERS, THEIR PROXIM TO OTHER UTILITIES, DESIGN CALCULATIONS. ETC. REFER TO 15A NCAC 02T .0305 Professional Engineer's Certification: (Signature of Design Engineer and Project Name) 1, Clark L. Thomas attest that this application for Cameron Elementary School Pump Station & Force Main has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although otherprofessionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25,000 per violation. 2a. Clark L. Thomas Professional Engineer Name 2b. McGill Associates, P.A. Engineering Firm 2c. 6 Regional Drive, Suite D Mailing Address 2d. Pinehurst 2e. NC 2f. 28374 City State Zip 2g. 910-295-3159 2h. 910-295-3647 Telephone Facsimile 2i. clark.thomas@mggillengineers.com E-mail SEt� 0 2 5 4 p' ��rgrrrrrrt>> NC PE FTA 12/07 PAY TO THE ORDER OF USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) 9. Owner/Permittee: 1a. Moore County Public School Full Legal Name (company, municipality, HOA, utility, etc.) 0 1b. Mr. John Hawthorne Signing Official Name and Title (Please review 15A NCAC 2T .0106 (b) for authorized signing officials!) a 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal ❑ Municipality ® State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify): 0 1 d. 5277 US Hwy 15-501 1 e. Carthage LL Mailing Address City Z 1f. North Carolina 1g. 28327 Z State Zip Code 0 1 h. 910-947-2976 1 i. 1j. 'hawthorne ncmcs.or Telephone Facsimile E-mail U2. Proiect (Facility) Information: J 2a. Cameron Elementary School Pump Station & Force Main 2b. Moore a a Brief Project Name (permit will refer to this name) County Where Project is Located a 3. Contact Person: Q 3a. Clark Thomas, McGill Associates, PA Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 910-295-3159 3c. clark.thomas@mcgillengineers.com Phone Number E-mail 1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: 2. Owner is ® Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Public Utility (Instruction C) ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction D) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 3. Moore County Public Utility Z Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 0 4a. Moore County Regional Water Pollution Control Plant 4b. NC 0037508 QName of WWTF WWTF Permit No. 5a. Moore County 5b. 8-inch Unknown W �Gravity5c. Owner of Downstream Sewer Receiving Sewer Size Permit # of Downstream Sewer (Instruction E) 0 6. The origin of this wastewater is (check all that apply): �p I McGill A S S O C I A T E S P.O. BOX 2259 - ASHEVILLE, NC 28802 PH: (828) 252-0575 Four Hundred Eighty and 00/100 Dollars NCDENR - Division of Water Quality BB&T BRANCH BANKING AND TRUST COMPANY North Carolina 66-112-531 038278 DATE March 18, 2011 AMOUNT 480.00 OPERATING ACCOUNT SIGNATURE ■ PAY TO THE ORDER OF @McGiR A S S O C I A T E S P.O. BOX 2259 - ASHEVILLE, NC 28802 PH: (828) 252-0575 Four Hundred Eighty and 00/100 Dollars NCDENR - Division of Water Quality BB&T BRANCH BANKING AND TRUST COMPANY North Carolina 66-112-531 038278 DATE March 18, 2011 AMOUNT 480.00 OPERATING ACCOUNT 3 UTHORIZED SIGNATURE OF WATF9 State of North Carolina Department of Environment and Natural Resources Division of Water Quality p -c Flow Tracking/Acceptance for Sewer Extension Permit Applications (FTSE—10/07) Project Applicant Name: I-IVort6 (LDvtni!SI Project Name for which flow is being requested: Czmmn Eleme JJ Se�wi( ,Vlore than one FTSE-10107 maybe required, for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. /244 a. WWTP Facility Name:+ - u e-a4eo► {p f ��-1 4hp 1 b. WWTP Facility Permit #: N _ 0031 S S All flows are in MGD c. WWTP facility's permitted flow -7 d. Estimated obligated flow not yet tributary to the WWTP 16 7 e. WWTP facility's actual avg. flow 4. S A 4- f. Total flow for this specific request 0. 66574 g. Total actual and obligated flows to the facility h. Percent of permitted flow used II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP Pump Station Name Approx. Capacity, MGD Approx. Current Avg. (Firm/Design) Daily Flow, MGD LIR-2 V-- 1 0.2452 V- 2 ©. & 4sb 5P4 4- s, a o. 7E 3 III. Certification Statement: I, �Dftntb R�r-1)6-6 ' , certify that, to the best of my knowledge. the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II for which I am the responsible party. Signature of this form indicates acceptance of this wastewater flow.'�H Signing Official Signature pate 08.04038 Alternative 1 (Straight down US-1 Bus) By Clark L. Thomas Date 17-Dec-2010 Cameron Elementary School Force Main Extension Input Data Qave. Qpeak ••III**• Qpump Scour Velocity Hammer Velocity Force Main Dia. Pump Cycle depth Wetwell Dia. Wetwell Area Calculated Cycles/Hour Ave. Cycles/Hour Peak Qave. @ 27sec Qave. @ 27s Qave. @ 107s Qpeak @ 27s Qpeak @ 107s Velocity @ Qpump Pump Run Time/24 hrs Find the flow for a given pipe Diameter Given Q=VA Qave = Q @ 27s = 78.34 gpm Qpeak = 195.84 gpm Find Pipe Diameter for Given Flow Q=VA Pipe Diameter for Average flow Q @ 27s 1.36 inches Q @ 107s 0.61 inches Pipe Diameter for Peak flow Q @ 27s 2.14 inches Q @ 107s 0.96 inches 360 Max # of Students 15 Gallons per day per student 5400 ADF gal/day 3.75 gpm 9 gpm 0.0054 MGD 10 hrs per day 22.5 gpm 0.0324 MGD 80 gpm This value is determined by taking the highest Q & 2 ft/sec Qpeak or Q @ 27sec for chosen pipe d 10 ft/sec 4 inches 1.5 ft 5ft 19.63 ft A For round wetwells ft A For wetwells that are not round 2.18 Cycles at Qave should be greater than 2 4.51 Cycles at Qpeak should be less than 8 78.34 gpm Given Pipe Diameter 1.36 inches Pipe Dia. given Flow data want smaller than this 0.61 inches Pipe Dia. Given Flow data 2.14 inches Pipe Dia. Given Flow data 0.96 inches Given Flow data want larger than this 2.05 fps Velocity in pipe at Qpump 2.67 hrs in a 24 hour period Find Wetwell volume for pump cycle depth ww Vol.= pump cycle depth * Area of wetwell * 7.48 gal/cf 220.19 gallons Fill time for ww vol. Fill time = ww vol. / Q Qave 24.47 minute Qpeak 9.79 minute Pump run time for ww vol. Pump run time = ww Vol. / Qpump 2.75 minute Adjusted pump run time (tpr) tpr = pump run time / Qpump * Qave Qave. 0.31 minutes Qpeak 0.77 minutes Cycle Time = Fill time + Pump Run Time + Adj. Pump Run time Qave. 27.53 minutes Qpeak 13.31 minutes Note: 448.83 gpm = 1 cfs Qpeak=Qave. * 2.5 ,`4ti►�tate�trs�s �q; CARpy''A',� 08.04038 Alternative 1 (Straight down US-1 Bus) 360 Max # of Students By Clark L. Thomas 15 Gallons per day per student Date 17-Dec-2010 5400 ADF gal/day Cameron Elementary School Force Main Extension 3.75 gpm Cycles per Hour = 60 min / Cycle time Qave. 2.18 Cycles at Qave should be greater than 2 Qpeak 4.51 Cycles at Qpeak should be less than 8 Pumping Data Specific Gravity of Fluid 1 Pump Efficiency 0.24 Motor Efficiency 0.95 Force Main Length (feet) 24600 System Curve for FM full Effective FM Length w/ Flow away 3700 TDH based on Hazen -Williams CL of Suction 382.5 C=100 C=120 C=140 Pump Off 366.5 Gal Per Min 0 Wetwell Rim Elev. 382.33 High point elevation 390 0 24.78 24.78 24.78 Discharge Pipe Diamter (inches) 4 5 24.96 24.91 24.88 Suction Pipe Dia. (inches) 4 10 25.43 25.24 25.13 Suction Bell Dia. (inches) 6 15 26.14 25.75 25.51 Flow Increment (gpm) 5 20 27.10 26.44 26.03 Force Main Size (inches) 4.0 25 28.28 27.28 26.66 Entrance Velocity (fps) 0.91 30 29.68 28.28 27.41 Calc. Submergence Depth(feet) #N/A 35 31.30 29.43 28.28 Residence Time in FM (hrs.)@Q ave. 2.97 40 33.13 30.74 29.26 Wetwell Depth (1.5' below submergence) #N/A 45 35.16 32.19 30.35 50 37.39 33.78 31.55 Station Losses 55 39.82 35.52 32.85 Static Suction Head 16 feet 60 42.45 37.39 34.26 65 45.27 39.40 35.78 Static Suction Losses 0.093 feet 70 48.28 41.55 37.39 Suction Minor Losses 75 51.48 43.84 39.11 Quantity Dia. (Inches) Fitting K Head 80 54.86 46.25 40.92 2 4 90 elbow 1.5 0.194 85 58.43 48.80 42.84 1 4 Entrance 0.2 0.013 90 62.19 51.48 44.85 95 66.12 54.29 46.97 Total Dynamic Suction Lift 16.300 100 70.24 57.22 49.17 105 74.53 60.29 51.48 Net Positive Suction Head 110 79.00 63.48 53.88 Atmospheric Psi in feet of H2O 33 115 83.65 66.80 56.37 Vapor Psi @74 degrees F 1 120 88.47 70.24 58.96 Safety Factor 2 125 93.47 73.80 61.64 Net Positive Suction Available 13.70 130 98.64 77.49 64.41 135 103.98 81.30 67.28 140 109.49 85.24 70.24 145 115.17 89.29 73.29 Discharge Minor Losses 150 121.02 93.47 76.42 Quantity Dia. (Inches) Fitting K Head 155 127.04 97.76 79.65 5 4 90 Elbow 0.30 0.097 160 133.22 102.18 82.97 4 4 Plug Valve 2.00 0.518 165 139.58 106.71 86.38 1 4 45 Elbow 0.20 0.013 170 146.09 111.36 89.88 1 4 exit Loss 1.00 0.065 175 152.78 116.13 93.47 180 159.62 121.02 97.14 Length of Pipe Dia. Pipe(ft) Inches Pipe Descrip. C Head 50 4 Pump Column 120.00 0.29012075 Total Minor Losses 0.983 180.00 160.00 140.00 120.00 $ 100.00 = 80.00 40.00 20.00 System Curve 0 50 100 150 200 250 300 350 400 450 gpm -�C 120 --E-C100 sir-C140 —Pump Curve -*--2 pumps in Parallel Circular Tank Floatation Calculations By: Clark Thomas Date: 18-Mar-11 Project: 8.04038 Cameron Pump Station Moore County Public Schools Cameron Pump Station PLAN VIEW OF CIRCULAR WETWELL Top Width Angle of Soil Influence ELEVATION VIEW OF WETWELL Input Data Wetwell Dimensions Inside Diameter Wall thickness Depth in Ground Height of Wetwell Top Thickness Hatch Area Unit Weight of Wetwell Angle of soil Influence Weight of Saturated Soil Soil Influence Line (Based on angle off vertical) Lip Around Wetwell bottom Wetwell Wall Thickness Inside Dimensions of Wetwell Height of Wetwell (from FFE to rim) Depth of Wetwell in Ground (from FFE to ground surface) FFE Lip Width ,0%J111111.tiI i* Alp 5 ft 0.67 ft 17ft _ • 17.5ft 0?S47 3 jr 19.63 sf 150 Ibs/Cf�Y\ 15 degrees = 0.261799388 Radians 46 Ibs/cf Manipulated values to Eliminate Tank Floatation Lip Width 0 ft Lip Bottom Thickness 1 ft Will the Tank Float NO Boyancy = 35,392 Weight of Tank + Soil = 39,734 P:\2008\08.04038-Mo. Co. Schools - Cameron Elementary Lift Station\Design Calcs\0804038 Floatation Calc for Wetwell.xlsCircular Wetwell 1 of3 Moore County Public Schools Cameron Pump Station Calculated Values Radius at Bottom of Wetwell _ ((inside dia /2) + wall t + lip) r2 = 3.167 Height of Cone below wetwell = Bottom Radius / tan(angle of influence) h2 = 11.8194 Radius at Top of Wetwell = Depth of wetwell + height of cone below wetwell) x tan (ang of influence) r1 = 7.722136 Height of Total Cone = h2 + Depth in ground h1 = 28.8194 1. Volume of soil displaced by tank from bottom FIFE Vol. = (ID+ t*2)^2/4 x (Depth of tank) Vol = 536 cf 2. Volume of Soil displaced from wetwell Bottom include lip Vol. = [(Inside Dia + 2 x (Wall t + Lip))^2/4 x Pi] x [Botton thickness] Vol = 32 cf 3. Volume of Soil Prism developed from angle of Influence from Bottom of Bottom Lip Vol. = [(Top Radius "2 * pio * 0.33 x Depth) - [0.33 x bottom Radius A x Pio x h2] - [[Inside Dia + 2 x (wall t + lip)]^2/4 x Depth] Total cone Vol. 1,781.7 ft Bottom Cone Vol. 122.9 ft Wetwell Vol = (WW + bottom lip) 567.2 ft Vol = 0 cf 5. Volume of Tank top Vol. = ODA2/4 x Pi x Top t) Vol = 32 cf 7. Boyancy of Tank Boyancy = [(Vol. Soil Displaced by tank to FIFE) + (Vol of Tank Bottom) ] x 62.4 lb/cf F= 35,392 Ibs up 8. Weight of Tank Weight of Tank= (Vol of Tank Bottom + Vol. Tank Top + Vol. Tank Walls) x Unit Wt. of WW Mat'I Fc= 39,734 Ibs Down P:\2008\08.04038-Mo. Co. Schools - Cameron Elementary Lift Station\Design Calcs\0804038 Floatation Calc for Wetwell.xlsCircular Wetwell 2of3 Moore County Public Schools Cameron Pump Station 9. Weight of Soil influencing tank Soil Wt = (Vol. on tank Lip + Vol of Soil Prism) x Unit Wt. of Soil Fs = 0 Ibs Down Wetwell Soil Volume Volume = large cone (h1) - small cc Cone Vol = 0.33 x R A 2 x Pio x P:\2008\08.04038-Mo. Co. Schools - Cameron Elementary Lift Station\Design Calcs\0804038 Floatation Calc for Wetwell.xlsCircular Wetwell 3of3 DESIGN NARRATIVE MOORE COUNTY PUBLIC SCHOOLS CAMERON ELEMENTARY SCHOOL SEWAGE PUMP STATION AND FORCE MAIN EXTENSION CAMERON, NORTH CAROLINA Date: April 20, 2011 McGill Associates Project Number 08.04038 Prepared by: McGill Associates, P.A. 6 Regional Drive, Suite D Pinehurst, North Carolina 28374 e4a`��6s�st��aage,®�� CAR _ Cz o 0254 '3 e MOORE COUNTY PUBLIC SCHOOLS CAMERON ELEMENTARY SCHOOL SEWAGE PUMP STATION AND FORCE MAIN EXTENSION INDEX SECTION Narrative....................................................................... Page No. 1-3 Route#1— US 1 Business Map............................................................................................. 4 08.04038 MCS/Cameron Elementary School/DWQ Narrative MOORE COUNTY PUBLIC SCHOOLS CAMERON ELEMENTARY SCHOOL SEWAGE PUMP STATION AND FORCE MAIN EXTENSION DESIGN NARRATIVE 1. GENERAL The project area is located in eastern Moore County in the town of Cameron. The purpose of the project is to enable the Cameron Elementary School (CES) to convey their wastewater discharge to Moore County Public Works and eliminate the current practice of wastewater disposal via septic tanks and leach fields. Currently CES has three (3) septic tanks, one (1) grease trap and two (2) leach fields to dispose of their wastewater generated on site. The off site disposal of the wastewater will permit the land to be used for other purposes. A lift station will be constructed on the south-eastern side of the school property and the force main will be installed inside the North Carolina Department of Transportation's (NCDOT) right-of-way from the elementary school and discharge into a manhole in the Town of Vass. 2. EXISTING SITE AND CONDITIONS The land gently rolls with grades generally ranging from 0% to 8% with loamy sands overlaying thick layers of sandy clay loam. The soils mainly consist of Fuquay loamy sand with other Dothan and Ailey loamy sands. These soils are well drained with low runoff potential. Wastewater from the school drains with the lay of the land and flows north to septic tanks and ultimately leach fields which have a very mild slope 0% to 2%. The septic tanks and leach fields date back to the 1940's when the school was built and have been maintained but the septic tank accesses are slabs of concrete which require heavy equipment to facilitate operations and maintenance. Concrete that has not been lined with any corrosion inhibitors will typically reach its useful design life in fifty (50) years or less depending on the compounds formed in the waste. The school board has realized that Cameron Elementary School's septic tanks have reached their useful design life and has approved an off -site wastewater conveyance system. 08.04038 MCS/Cameron Elementary School/DWQ Narrative 1 MOORE COUNTY PUBLIC SCHOOLS CAMERON ELEMENTARY SCHOOL SEWAGE PUMP STATION AND FORCE MAIN EXTENSION 3. WASTEWATER CONVEYANCE SYSTEM A. Sewage Pump Station Site The location of the sewage pump station at the Cameron Elementary School site was selected based on a meeting with Moore County Public School System staff and McGill Associates on January 6, 2011 using the following criteria: 1. The availability of three (3) phase power. Three (3) phase power enters the school site at the south-east corner. 2. Access for maintenance vehicles. The service entrance to the school cafeteria, heating oil tank and teacher parking is adjacent to the proposed site. 3. The ability to gravity feed the wastewater generated on -site to the pump station. A proposed gravity collection system from the north end of campus to the south-east will serve the existing buildings on campus and open up other areas for future building. B. Force Main Route Two (2) force main routes were reviewed and the selected route is described below. A 4-inch force main provides the optimum hydraulics for both routes with respect to power demands and pumping capacity. The selected route runs east on the south side of Hwy 24-27 then runs on the west side of US-1 Business south to the discharge manhole in the Town of Vass, see map G-001. The force main utilizes existing road right-of-ways to minimize the need for easement acquisition and to provide better access for maintenance in the event of a line break. The route will have two (2) creek bores under blue line streams and cross over NCDOT culverts that show up as blue line streams on the United States Geological Survey (USGS) quad sheet. The proposed force main will be installed deeper than the minimum cover due to parallel installations of potable water lines. US-1 Business has a 16-inch ductile iron potable water line running in the west shoulder and a 6-inch water line in the east shoulder; therefore it will be necessary to install the force main 18-inches deeper than the bottom of the water line to meet North Carolina Department of Environment and Natural Resources (NCDENR) separation requirements. Two (2) 08.04038 MCS/Cameron Elementary School/DWQ Narrative 2 MOORE COUNTY PUBLIC SCHOOLS CAMERON ELEMENTARY SCHOOL SEWAGE PUMP STATION AND FORCE MAIN EXTENSION creek crossings will be bored to minimize impacts to the streams and eliminate the need to obtain environmental permits from the US Army Corps of Engineers (USACOE) and the North Carolina Division of Water Quality (NCDWQ). 4. RECOMMENDATIONS McGill Associates, P.A. recommends Alternative #1 for ease of construction and the most economical solution for wastewater conveyance. Wastewater will have a six (6) day residence time in the force main and will produce corrosive hydrogen sulfide compounds; therefore it is recommended that the pump station have a chemical feed system that directly injects into the force main to reduce the production of these compounds. The receiving manhole and adjacent pump station will be lined with a corrosion inhibiting compound to protect the structural integrity of the manhole and wetwell. The force main will be equipped with an emergency by-pass connection, which, in the event the pump station has a catastrophic failure, a portable pump must be utilized to discharge directly into the force main. The force main will have multiple emergency by-pass connections to be used for cleaning and flushing the force main. The force main route has large sags and low flows which will cause solids to accumulate in the low points in the line. Flushing the line as part of a maintenance program will clear the force main of solids and provide many years of reliable service. It is recommended that the force main be flushed at a velocity of 3.5 feet per second or 310 gallons per minute (gpm). A temporary flow meter will provide the maintenance staff useful information with respect to flow rates during flushing activities. Recommendations Summary: • Alternate Route #1 — 24,600-feet of 4-inch PVC force main along US-1 Business. • Line receiving manhole and adjacent wetwell with corrosion resistant coating. • Inject Chemical feed at the pump station to reduce formation of corrosive compounds. • Flush line — as part of a maintenance operation at 310 gpm. • Install a by-pass pump connection station at pump station and several points along force main to facilitate cleaning the force main. 08.04038 MCS/Cameron Elementary School/DWQ Narrative 3 7,-]-McGffl A S S O C I A T E S April 11, 2011 Ms. Belinda Henson Surface Water Protection Supervisor North Carolina Division of Water Quality 225 Green Street, Suite 714 Fayetteville, North Carolina 28301-5043 RE: Cameron Elementary School Pump Station and Force Main Moore County Schools Carthage, North Carolina Dear Ms. Henson: Please find enclosed for your review and approval the following items related to the above referenced project: • One (1) original and one (1) copy of the Fast Track Application for Gravity Sewers, Pump Stations and Force Mains (FTA 12/07) • One (1) original and one (1) copy of the Flow Tracking Form (FTSE 10/07) • Two (2) copies of a project narrative with a location map and design calculations for the pump station and force main • A check in the amount of $480 to cover the application fee The proposed project includes the installation of a new lift station and approximately 24,600 linear feet of 4-inch diameter force main and related appurtenances to convey wastewater from the Cameron Elementary School to the existing wastewater collection system serving the Town of Vass. The force main crosses under two (2) blue line streams via directional drill and at all other stream crossings the force main crosses over a NCDOT culvert. Therefore, this project will have no impact to the waters of the State and does not require an Environmental Assessment. E n g i n e e r i n g P l a n n i n g a F i n a n c e McGill Associates, P.A. - 6 Regional Drive, Suite D, Pinehurst, NC 28374 910-295-3159 - Fax: 910-295-3647 If you have any questions or require additional information regarding this project, please feel free to contact me at 910-295-3159. Sincerely, McGILL ASSOCIATES, P.A. Clark L. Thomas, PE Sr. Project Engineer Enclosures cc: John Hawthorne, Moore County Schools 08.04038/bh.FTA 11 April 2011