Loading...
HomeMy WebLinkAboutWQ0034111_More Information (Requested)_20090811V., NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director August 11, 2009 Mr. Brent Lockamy Town of Southern Pines 140 Memorial Park Ct. Southern Pines, North Carolina 28387 Dee Freeman Secretary Subject: Request for Additional Information Town of Southern Pines Permit No. WQ0034111 Cypress Creek Subdivision Sewer System Extension Moore County Dear Mr. Lockamy: A review of the plans and specifications in support of the permit application package has been completed by the Construction Grants and Loans Section (CG&L). The comments resulting from this review are being transmitted directly to your engineer for clarification and resolution; a copy is attached for your reference. Our goal is to issue the Wastewater Collection Permit as soon as possible. If a complete response is not received within 30 days, the application and supporting information will be returned. Upon receipt of satisfactory responses from your engineer to our comments, the review of the plan documents will be completed. If you have any questions concerning this matter, please do not hesitate to contact Adrian Eaton, State Project Review Engineer, at (919) 715-3283. Sincerely, >_ - Seth Robertson, P.E., Supervisor Construction Grants and Loans Section Design Management Unit ae/sr Attachment to all cc: Mr. James R. Honeycutt, P.E., Honeycutt Engineering Company, 610 Hidden Valley Road, Wilmington, North Carolina 28409 DWQ Fayetteville Regional Office, Surface Water Protection (Permit No. NC0037508) Permit Application File WQ0034111 1617 Mail Service Center, Ralegh, North Carolina 27699-1617 Location: 512 N. Salisbury St. Ralegh, North Carolina 27604 Phone: 919-807-63001 FAX: 919-807-64921 Customer Service: 1-877-623-6748 Internet: www.ncwaterquality.org An Equal Opportunity 1 Affirmative Action Employer NorthCarolina Naturally I Construction Grants & Loans Section Design Management Unit Town of Southern Pines Cypress Creek Subdivision Sewer System Extension Permit No. WQ0034111 Request for Additional Information General: 1. All lot sewer laterals crossing a water main in the right-of-way must be installed in accordance with 15A NCAC 02T .0305 (f). Provide a detail on the plan sheets. 2. Confirm that the entire project is located outside the 100-year flood elevation. 3. Confirm that the project has a minimum separation of 50-foot from any WS-IV classified waters. 4. Provide a letter from Town of Southern Pines accepting and verifying that the existing sewer collection system has the capacity to accept the project sewer flow of 30,960 GPD. (Note: Reference submitted letter from Moore County Public Utilities dated May 21, 2009). 5. Provide the pump curve along with the system curves, and call out the operating points. 6. Provide the backup generator specifications. 7. Provide a pump station site plan to include the pump station (PS), valve box, fencing, road access, telemetry, emergency generator/pad, control box, electrical MMC panel. 8. Provide an electrical schematic for PS (include emergency backup, pump controls, pump alarms, etc...). 9. Provide confirmation that each of the 86 townhomes has a separate proposed lateral that ties into the proposed common 8-inch gravity. Calculations: 1. Provide the engineering calculations verifying that the downstream receiving existing fl- inch gravity sewer has the capacity to handle the projects flow. 2. Where does the existing receiving 8-inch gravity sewer outfall7 Does this sewer have capacity to handle the project flow? Continue the downstream analysis to the headworks of the receiving W WTF. 3. Provide the engineering calculations for the proposed 8-inch gravity sewer. 4. Provide the high velocity protection methods to be used. Refer to the MDC for Permitting Gravity Sewers, Part III (D) (5) document located on the CG & L website. www.nccgl.net 5. Provide the steep slope protection methods to be used. Refer to the MDC for Permitting Gravity Sewers, Part III (D) (6) document located on the CG & L website. www.nccgl.net Plans: 1. Plan sheet C2: a. Confirm that the proposed gravity laterals meet 15A NCAC 02T .0305 when crossing water main. b. Provide the plan and profile view for the proposed 4-inch force main. c. Provide the proposed slope ft/ft on the sanitary sewer manhole chart. d. Provide an additional column to the sewer manhole chart showing velocities at the proposed slopes. 2. On all plan sheets, call out the type of manholes being proposed. Refer to the MDC for Permitting Gravity Sewers, Part IV (B) document located on the CG & L website. www.nccgl.net Note: Part IV (C) (2) for the requirements of inside drop manholes. 3. Plan sheet C3: Provide a profile and plan view for the proposed gravity out of MH #5 to invert in at the proposed PS (wet well). Specifications: 1. Page 12 (section 07): the minimum separation for sewer crossing storm is shown as 12- inches. Provide clarification. 2. Provide the deflection test methods to be used. Refer to the MDC for Permitting Gravity Sewers, Part III (H) (6) document located on the CG & L website. www.nccgl.net 3. Provide the hydrostatic and air testing methods to be used. Refer to the MDC for Permitting Gravity Sewers, Part III (I) (3) / (4) document located on the CG & L website. www.nccgl net 4. Provide methods being used for manhole watertightness. Refer to the MDC for Permitting Gravity Sewers, Part IV (F) document located on the CG & L website. www.nccgl.net 5. Provide methods being used for manhole corrosion protection. Refer to the MDC for Permitting Gravity Sewers, Part IV (I) document located on the CG & L website. www.nccgl.net 6. Provide the methods being used to comply to all sections in Part (VI) of the MDC for Permitting Gravity Sewers. This document can be downloaded from the CG & L website. www.nccgl.net