Loading...
HomeMy WebLinkAboutWQ0038695_NOV-2020-LM-0051_20200527ROY COOPER Govemor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director Jeff Malarney OBX Waterpark Adventure, LLC 13 Green Mountain Cohoes, NY 12047 SUBJECT: NOTICE OF VIOLATION NORTH CAROLINA Environmental Quality May 27, 2020 Tracking Number: NOV-2020-LM-0051 Permit No. WQ0038695 OBX Waterpark Adventure WWTP Currituck County Dear Mr. Malarney: A review of the July 2019 Non -Discharge Monitoring Report (NDMR) for the subject facility revealed the violation(s) indicated below: Limit Exceedance Violation(s): Sample Limit Reported Location Parameter Date Value Value Type of Violation 001 BOD, 5-Day (20 Deg. C) 7/31/2019 10 21.5 Monthly Average Exceeded (00310) 001 Coliform, Fecal MF, MFC Broth, 7/31/2019 14 1,097.77 Monthly Geometric Mean Exceeded 44.5 C (31616) 001 Nitrogen, Ammonia Total (as 7/31/2019 4 79.3 Monthly Average Exceeded N) (00610) 001 Nitrogen, Total (as N) (00600) 7/31/2019 4 95.41 Monthly Average Exceeded 001 Phosphorus, Total (as P) 7/31/2019 2 9.86 Monthly Average Exceeded (00665) No rth Cam line Uepsft ent of Environmental Quality I Division of Water Resources Washington Regional Off 1 943 Washington Square MMI I Washington, North Csm!ins 27339 k 252$46-643J. Limit Exceedance Violation(s): Sample Limit Reported Location Parameter Date Value Value Type of Violation 001 Solids, Total Suspended 7/31/2019 15 31.4 Monthly Average Exceeded (00530) Monitoring Violation(s): Sample Monitoring Location Parameter Date Frequency Type of Violation 001 Flow, in conduit or thru treatment 7/1/2019 Continuous Frequency Violation plant (50050) 001 Flow, in conduit or thru treatment 7/2/2019 Continuous Frequency Violation plant (50050) 001 Flow, in conduit or thru treatment 7/9/2019 Continuous Frequency Violation plant (50050) 001 Flow, in conduit or thru treatment 7/16/2019 Continuous Frequency Violation plant (50050) 001 Flow, in conduit or thru treatment 7/22/2019 Continuous Frequency Violation plant (50050) 001 Flow, in conduit or thru treatment 7/23/2019 Continuous Frequency Violation plant (50050) 001 Flow, in conduit or thru treatment 7/30/2019 Continuous Frequency Violation plant (50050) 001 Flow, in conduit or thru treatment 7/31/2019 Continuous Frequency Violation plant (50050) Remedial actions, if not already implemented, should be taken to correct any noted problems. The Division of Water Resources may pursue enforcement actions for this and any additional violations. If the violations are of a continuing nature, not related to operation and/or maintenance problems, and you anticipate remedial construction activities, then you may wish to consider applying for a Special Order by Consent (SOC). If you have any of the frequency violation/parameter missing documentation to report, please make the necessary revisions (write revisions on the front page) to the original Non -Discharge Monitoring Report (NDMR) and return the form(s) by email t0 Non-Discharge.Reports(a)_ncdenr.gov. No rth Cam line Uepsft ent of Environmental Quslily I Division of Water Resources Washington Regions) 4f :oe 1943 Washington Square MMI I Washington, North Cam!ins 27339 k 252$46-6431 If you have any questions concerning this matter or to apply for an SOC, please contact Sarah Toppen of the Washington Regional Office at 252-948-3845. Sincerely, IzTl Robert Tankard, Assistant Regional Supervisor Water Quality Regional Operations Section Washington Regional Office Division of Water Resources, NCDEQ Cc: Laserfiche No rth Cam line Uepsft ent of Environmental Quslily I Division of Water Resources Washington Regions) 4f :oe 1943 Washington Square MMJ I Washington, North Cam!ins 27339 k 252$46-6431