Loading...
HomeMy WebLinkAboutWQ0041688_Application (FTSE)_20200522Permit Number WQ0041688 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer dean.hunkele Coastal SWRule Permitted Flow Facility Central Files: APS _ SWP 5/14/2020 Permit Tracking Slip Status Project Type In review New Project Version Permit Classification A Individual Permit Contact Affiliation Facility Name Major/Minor Region Waverly Place Mixed Use Development Minor Wilmington Location Address County Onslow Owner Owner Name Onslow Water and Sewer Authority Dates/Events Scheduled Orig Issue App Received Draft Initiated Issuance 5/11/2020 0 TO: Mr. Dean Hunkele NCDENR - DWR ENGINEERS• SURVEYORS• PLANNERS 127 Cardinal Drive Extension Wilmington, NC 28405-3845 WE ARE SENDING YOU: LETTER OF TRANSMITTAL DATE: May 7, 2020 ECEIVE MAY 9 i 2U20 REF: Waverly Place Sewer Improvements Fast Track Sewer Application One (1) Original and One (1) Copy of the Fast Track Sewer Application; One (1) Check No. 40209 in the amount of $480.00 for the application fee; Two (2) Flow Tracking/Accepance Forms; and One (1) Portion of the USGS Map. DELIVERY VIA: 0 Regular Mail ❑ Hand ❑ Federal Express ❑ UPS Overnight ❑ UPS Ground ❑ Other THESE ARE TRANSMITTED AS CHECKED BELOW: ❑x For Approval ❑ As Requested ❑ For Review and Comment ❑ For Your Use ❑ For Bids Due ❑ Other COMMENTS: 414 / to 4—c-r — Antliony G. moctezuma Staff Engineer ec: A. Sydes Construction, Inc. (LOT Only) Ms. Wynne Ray - ONWASA (w/paperwork) AGM/brs CF (P), LAM (if enclosures are not as noted, kindly notify us at once) secretary.c2.2020.Foms. WaverlyPlace.LOT.Hunkele. WaverlyPlace.FmtTrackSewec5.7.2020 306 New Bridge Street I P.O. Box 976 I Jacksonville, NC 28541-0976 I (910) 455-2414 Firm License Number F-0108 I www.parkerjacksonville.com State of North Carolina DWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: W (G Q Q 16 SO (to be completed by DWR) All items must be completed or the anplication will be returned I. APPLICANT INFORMATION: 1. Applicant's name: ONWASA (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Federal ❑ State/County ® Municipal 3. Signature authority's name: David Mohr. P.E. per 15A NCAC 02T .0106(b) Title: Chief Operations Officer 4. Applicant's mailing address: 228 Georgetown Road City: Jacksonville State: NC Zip: 28540-. 5. Applicant's contact information: Phone number: (910) 455-0722 Email Address: dmohrAonwasa.com II. PROJECT INFORMATION: 1. Project name: Waver] Place ❑ Privately -Owned Public Utility ❑ Other 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Onslow 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.9095' Longitude:-77.5741' 5. Parcel ID (if applicable): 027670 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Jason A. Houston, P.E. License Number: 34978 Firm: Parker & Associates. Inc. Mailing address: 306 New Bridge Street City: Jacksonville State: NC Zip: 28540-_ Phone number: (9455-2414 Email Address: office@parkerjacksonville.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Northwest Regional Water Reclaimation Facility Permit Number: W00034367 Owner Name: ONWASA V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0003445 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS pAg J 1 Owner Name(s): ONWASA FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial 0 % Commercial 0 % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ® No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ®No ➢ If yes, provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T,0114(f) Daily Design Flow °'b No. of Units Flow Dwelling Unit 360 gal/Unit 105 37,800 GPD Commercial Tract 880 gal/acre 1.8 1,584 GPD gal/ GPD gal/ GPD gal/ GPD gaV GPD Total 39,384 GPD a See 15A NCAC 02T .0114(b). (d). (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table I SA NCAC 02T 0114j shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 39384 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: WO003518 ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 4,064 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIll. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC_(Pumn Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 1 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.90560 Longitude:-77.5769' 3. Design flow of the pump station:.037 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 92 gallons per minute at 28 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 4" 2,428 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B).' ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)): 1. Does the project comply with all separations found in I SA NCAC 02T .0305(f) & (n) ® Yes ❑ No ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water (or tide elevation) and wetlands see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webna¢e ➢ If noncompliance with 02T.0305(f) or (2). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ®N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or [-]Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.04021 "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump S. tatigM and Force Mains (latest version), and the Gravity Sewer Minimum Desien Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and su000rtina documents. 2. Professional Engineer's Certification: name from Application Item III.1.) attest that this application for has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6E, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.,, I I I I I u. North Carolina Professional Engineer's seal, signature, and date: 'ems®� Q • • %:"!�%i�� ti n: SEAL 9r' •. 9 1IM 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Uavlq M. Monr, f .t., L:ii4v Operations utticef attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6d, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Date: O-0{%�ZD FORM: FTA 04-16 Page 5 of 5 t II%1on of Watei ftk"oarce: Entity Requesting Allocation: ONWASA State of North Carolina Department of Environmental Quality Division of Water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Project Name for which flow is being requested: Waverly Place More than one FTSE cony be required for a single project if the owner of the WWTP is not responsible for all pomp stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: NWRWRF b. WWTP Facility Permit #: WQ0034367 Al! flows are in MGD c. WWTP facility's permitted flow 1.2 d. Estimated obligated flow not yet tributary to the WWTP e. WWTP facility's actual avg. flow f. Total flow for this specific request g. Total actual and obligated flows to the facility h. Percent of permitted flow used .0374 .4177 .0039 .459 38% II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: Pump Pump Station Station Firm (Name or Permit Capacity, Number) No. MGD WOTS -15 WQ0032367 2.45 (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Average Approx. Obligated, Daily Current Not Yet Total Current Flow** Avg. Daily Tributary Flow Plus (Firm / pf), Flow, Daily Flow, Obligated Available MGD MGD MGD Flow Capacity*** .69 .4177 .0413 .459 .231 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): ONWASA Downstream Permit Number: WQ0032367 Page 1 of 6 FTSE 10-18 III. Certification Statement: I David M. Mohr, P.E. certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing fficial Signature D to jo�'If,EF- DPeY2A7orJS Dr-�IG�2 `�����N�CAR0�i,�� Title of Signing Official0FBsstp GL'� :a SEAL ITET M� Page 2 of 6 FTSE 10-18 5/14/2020 Go<:.1gie Maps 34054'34.2"N 77034'26.8"W 0 Haul NeighbDorhood Dealer d m R'�manda NSy. s Zx vra Brands a Beauty Salon V h, a_ a� Scotty Bay Automotive P kc 34°54'34.2"N 77`34'26.8"W - Google Maps a `'a m 0 wcnww: raw u� Anderson Trophies K"on Hwy First Christian Church 9 _ 3 fT5 1y- East Coast Mobile Dollar Tree@— Home Sales & Service V q'bM .........,. Walman SupercenterQ �oejx United Pentecostal© Ny '. Church Walman Auto Care CentersQ Taco Belle. lempnraNy Go^.M Liberty Christian Jones Funeral Home Academy© HabanerosQ Q temowuuy aosen 4QF �NAPA Al Bellingei Hwy 55 Burge Shakes & Fri, ao Food Lion 9 eoI Google axe E Map data ©2020 500 ft 5 https://WWW.google.wm/maps/place/34°54'34.2"N+77'34'26.8"W/@34.9086a4, 77.574459,16zldata=!4m5!3m4!1 sCxO:OxO!8m2!3d34.9095!4d-77.5741?hl=en 1/2