Loading...
HomeMy WebLinkAboutWQ0005681_Final Permit_20200527ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director JAMAL MOHAMMED — COMPLEX MANAGER PILGRIM'S PRIDE CORPORATION 484 ZIMMERMAN ROAD SANFORD, NORTH CAROLINA 27330-0519 Dear Mr. Mohammed: NORTH CAROLINA Environmental Quality May 27, 2020 Subject: Permit No. WQ0005681 Pilgrim's Pride — Staley WWTP Wastewater Irrigation System Randolph County In accordance with your permit renewal request received March 30, 2020, we are forwarding herewith Permit No. WQ0005681 dated May 27, 2020, to Pilgrim's Pride Corporation for the continued operation of the subject wastewater treatment and irrigation facilities. Please note that this renewed permit shall become effective on November 1, 2020 (i.e., the day after the expiration date of the existing permit). This permit shall be effective from November 1, 2020 through November 30, 2026, shall void Permit No. WQ0005681 issued August 27, 2015, and shall be subject to the conditions and limitations therein. The Permittee shall submit a renewal application no later than June 3, 2026. Please pay attention to the monitoring requirements listed Attachments A, B, and C for they may differ from the previous permit issuance. Failure to establish an adequate system for collecting and maintaining the required operational information shall result in future compliance problems. The Division has removed the following permit condition since the last permit issuance dated August 27, 2015: ➢ Old Condition VL2. — This condition has been removed because the permit is not voidable. The following permit conditions are new since the last permit issuance dated August 27, 2015: ➢ Condition 11.11. —All setbacks applicable to 15A NCAC 02H .0219 have been added. ➢ Condition IIL 16. — Metering equipment shall be tested and calibrated annually. ➢ Condition IV.9. — The maintenance log shall now also include records of irrigation equipment calibration. ➢ Condition VL 10. —This permit shall not be renewed if the Permittee or any affiliation has not paid the required annual fee. ➢ Attachment A — Parameters have been added to the effluent monitoring requirements for consistency with the Division's Effluent Monitoring Policy dated February 9, 2016. D Q �� North Carolina Department of Environmental Quality I Division of Water Resources 512 North Salisbury Street 1 1617 Mail Service Center j Raleigh, North Carolina 27699-1617 NORTH CAROLINA i 919.707.9000 Mr. Jamal Mohammed May 27, 2020 Page 2 of 2 ➢ Attachment C — Total Phosphorus has been added to the requirements for groundwater sampling. If any parts, requirements, or limitations contained in this permit are unacceptable, the Permittee has the right to request an adjudicatory hearing upon written request within 30 days following receipt of this permit. This request shall be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings at 6714 Mail Service Center, Raleigh, NC 27699-6714. Otherwise, this permit shall be final and binding. If you need additional information concerning this permit, please contact Poonam Giri at (919) 707-3656 or poonam.girikncdenr.gov. Sincerely, S. Daniel Smith, Director Division of Water Resources cc: Randolph County Health Department (Electronic Copy) Winston-Salem Regional Office, Water Quality Regional Operations Section (Electronic Copy) Robert T. Branch, LSS — Branch Residuals & Soils, L.L.C. (Electronic Copy) Laserfiche File (Electronic Copy) Digital Permit Archive (Electronic Copy) NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENTAL QUALITY RALEIGH WASTEWATER IRRIGATION SYSTEM PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO Pilgrim's Pride Corporation Randolph County FOR THE continued operation of a 13,000 gallon per day (GPD) wastewater treatment and irrigation facility consisting of: a 1,500 gallon lift station with two 25 gallon per minute (GPM) pumps and controls; a 2,000 gallon lift station with two 25 GPM pumps and controls; a 5,000 gallon aerated flow equalization tank with two 30 GPM pumps and controls; a package plant consisting of a 20,000 gallon aerated tank with diffusers, a 3,395 dual hopper clarifier, a 1,400 gallon sludge holding tank, and associated blowers, piping and controls; two tablet chlorinators; a 204,000 gallon treatment lagoon and 204,000 gallon storage tank in series; an effluent flow meter; an irrigation pump house with a 15 horsepower (hp) Baldor irrigation pump, a 0.5 hp Myers priming pump, and an effluent flow meter; a 6.27 acre spray irrigation area; and all associated piping, valves, controls, and appurtenances to serve the Pilgrim's Pride — Staley WWTP, with no discharge of wastes to surface waters, pursuant to the application received March 30, 2020, and in conformity with the Division -approved plans and specifications considered a part of this permit. This permit shall be effective from November 1, 2020 through November 30, 2026, shall void Permit No. WQ0005681 issued August 27, 2015 and shall be subject to the following conditions and limitations: L SCHEDULES 1. The Permittee shall request renewal of this permit on Division -approved forms no later than June 3, 2026. [15A NCAC 02T .0105(b), 02T .0109] II. PERFORMANCE STANDARDS The Permittee shall maintain and operate the subject non -discharge facilities so there is no discharge to surface waters, nor any contravention of groundwater or surface water standards. In the event the facilities fail to perform satisfactorily, including the creation of nuisance conditions due to improper operation and maintenance, or failure of the irrigation areas to assimilate the effluent, the Permittee shall take immediate corrective actions, including Division required actions, such as the construction of additional or replacement wastewater treatment or disposal facilities. [15A NCAC 02T .0108(b)(1)(A)] WQ0005681 Version 5.0 Shell Version 200201 Page 1 of 9 2. This permit shall not relieve the Permittee of their responsibility for damages to groundwater or surface water resulting from the operation of this facility. [15A NCAC 02T .0108(b)(1)(A)] 3. Groundwater monitoring wells shall be constructed in accordance with 15A NCAC 02C .0108 (Standards of Construction for Wells Other than Water Supply), and any other jurisdictional laws and regulations pertaining to well construction. [15A NCAC 02C .0108] 4. Effluent quality shall not exceed the limitations specified in Attachment A. [15A NCAC 02T .0108(b)(1)(A)] 5. Application rates, whether hydraulic, nutrient, or other pollutant, shall not exceed those specified in Attachment B. [15A NCAC 02T .0108(b)(1)(A)] 6. Wastewater irrigation fields permitted on or after December 30, 1983 have a compliance boundary that is either 250 feet from the wastewater irrigation area, or 50 feet within the property boundary, whichever is closest to the wastewater irrigation area. Any exceedance of groundwater standards at or beyond the compliance boundary shall require corrective action. Division -approved relocation of the compliance boundary shall be noted in Attachment B. Multiple contiguous properties under common ownership and permitted for use as a disposal system shall be treated as a single property with regard to determination of a compliance boundary. [15A NCAC 02L .0106(d)(2), 02L .0107(b), 02T .0105(h), G.S. 143-215.1(1), G.S. 143-215.1(k)] 7. The review boundary is midway between the compliance boundary and the wastewater irrigation area. Any exceedance of groundwater standards at or beyond the review boundary shall require preventative action. [15A NCAC 02L .0106(d)(1), 02L .0108] 8. The Permittee shall apply for a permit modification to establish a new compliance boundary prior to any sale or transfer of property affecting a compliance boundary (i.e., parcel subdivision). [ 15A NCAC 02L .0107(c)] 9. No wells, excluding Division -approved monitoring wells, shall be constructed within the compliance boundary except as provided for in 15A NCAC 02L .0107(g). [15A NCAC 02L .0107] 10. Except as provided for in 15A NCAC 02L .0107(g), the Permittee shall ensure any landowner who is not the Permittee and owns land within the compliance boundary shall execute and file with the Randolph County Register of Deeds an easement running with the land containing the following items: a. A notice of the permit and number or other description as allowed in 15A NCAC 02L .0107(f)(1); b. Prohibits construction and operation of water supply wells within the compliance boundary; and c. Reserves the right of the Permittee or the State to enter the property within the compliance boundary for purposes related to the permit. The Director may terminate the easement when its purpose has been fulfilled or is no longer needed. [15A NCAC 02L .0107(f)] WQ0005681 Version 5.0 Shell Version 200201 Page 2 of 9 11. The facilities herein were permitted per the following setbacks: a. The irrigation sites were modified March 5, 2003. The setbacks for spray irrigation sites originally permitted or modified from February 1, 1993 to August 31, 2006 are as follows (all distances in feet): I. Each habitable residence or place of assembly under separate ownership: 4001 ii. Each private or public water supply source: 100 iii. Surface waters: 100 iv. Groundwater lowering ditches: 100 v. Surface water diversions (upslope): 100 vi. Surface water diversions (downslope): 100 vii. Each well with exception of monitoring wells: 100 viii. Each property line: 150 2 ix. Top of slope of embankments or cuts of two feet or more in vertical height: 15 x. Each water line: 10 xi. Each swimming pool: 100 xii. Public right of way: 50 xiii. Nitrification field: 20 xiv. Each building foundation or basement: 15 ' Habitable residences or places of assembly under separate ownership constructed after the facilities herein were originally permitted or subsequently modified are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. [15A NCAC 02H .02190)(5)] b. The storage and treatment units were modified March 5, 2003. The setbacks for storage and treatment units originally permitted or modified from February 1, 1993 to August 31, 2006 are as follows (all distances in feet): I. Each private or public water supply source: 100 ii. Surface waters: 50 iii. Each well with exception of monitoring wells: 100 iv. Each property line: 50 2 v. Nitrification field: 20 ' Habitable residences or places of assembly under separate ownership constructed after the facilities herein were originally permitted or subsequently modified are exempt from this setback. 2 Setbacks to property lines are not applicable when the Permittee, or the entity from which the Permittee is leasing, owns both parcels separated by the property line. [15A NCAC 02H .02190)(5)] WQ0005681 Version 5.0 Shell Version 200201 Page 3 of 9 III. OPERATION AND MAINTENANCE REQUIREMENTS 1. The Permittee shall operate and maintain the subject facilities as anon -discharge system. [15A NCAC 02T .0500] 2. The Permittee shall maintain an Operation and Maintenance Plan, which shall include operational functions, maintenance schedules, safety measures, and a spill response plan. [15A NCAC 02T .0507(a)] 3. Upon the Water Pollution Control System Operators Certification Commission's (WPCSOCC) classification of the subject non -discharge facilities, the Permittee shall designate and employ a certified operator in responsible charge (ORC), and one or more certified operators as back-up ORCs. The ORC or their back-up shall operate and visit the facilities as required by the WPCSOCC. [15A NCAC 02T .0117] 4. The Permittee shall maintain vegetative cover on the irrigation sites, such that crop health is optimal, allows even effluent distribution, and allows inspection of the irrigation system. [15A NCAC 02T .0507(b)] 5. The Permittee shall take measures to prevent effluent ponding in or runoff from the irrigation sites listed in Attachment B. [15A NCAC 02T .0507(c)] 6. The Permittee shall not irrigate treated effluent during inclement weather, or when the soil is in a condition that will cause ponding or runoff. [15A NCAC 02T .0505(x)] 7. Irrigation equipment shall be tested and calibrated once per permit cycle. [15A NCAC 02T .0507(d)] 8. Only treated effluent from the Pilgrim's Pride — Staley WWTP shall be irrigated on the sites listed in Attachment B. [15A NCAC 02T .0501] 9. The Permittee shall not allow vehicles or heavy machinery on the irrigation area, except during equipment installation or maintenance activities. [15A NCAC 02T .0507(e)] 10. The Permittee shall prohibit public access to the wastewater treatment, storage, and irrigation facilities. [15A NCAC 02T .0505(q)] 11. The Permittee shall dispose or utilize generated residuals in a Division -approved manner. [15A NCAC 02T .0508, 02T .I 100]. 12. The Permittee shall not divert or bypass untreated or partially treated wastewater from the subject facilities. [15A NCAC 02T .05050)] 13. Freeboard in the 204,000 gallon treatment lagoon and the 204,000 storage lagoon shall not be less than one foot at any time. The Permittee shall reduce production and therefore reduce wastewater flow at any time the wastewater in either the treatment lagoon or the storage lagoon is at the one foot freeboard level. Upon notification by the Division that the freeboard requirement is becoming a continuous concern, the Permittee shall reduce wastewater treatment flow back to the previously permitted 10,000 GPD immediately. [15A NCAC 02T .0505(d)] 14. Gauges to monitor waste levels in the 204,000 gallon treatment lagoon and the 204,000 storage lagoon shall be provided. These gauges shall have readily visible permanent markings, at inch or tenth of a foot increments, indicating the following elevations: maximum liquid level at the top of the temporary liquid storage volume; minimum liquid level at the bottom of the temporary liquid storage volume; and the lowest point on top of the dam. [15A NCAC 02T .0507(f)] WQ0005681 Version 5.0 Shell Version 200201 Page 4 of 9 15. A protective vegetative cover shall be established and maintained on all berms, pipe runs, erosion control areas, surface water diversions, and earthen embankments (i.e., outside toe of embankment to maximum allowable temporary storage elevation on the inside of the embankment). Trees, shrubs, and other woody vegetation shall not be allowed to grow on the earthen dikes or embankments. Earthen embankments shall be kept mowed or otherwise controlled and accessible. [15A NCAC 02T .0507(g)] 16. Metering equipment shall be tested and calibrated annually. [15A NCAC 02T .0507(d)] 17. For the pump station, the plant operation shall either have a replacement pump of the same size, or a source of replacement nearby, as backup in case of emergency. The replacement pumping unit shall be maintained in good condition on site at the facility for use in the event there is a pump failure. In the event of a high water situation, the facility management shall ensure that no bypass of treatment or discharge of untreated wastewater occurs. [15A NCAC 02T .0 1 08(b)(1)(A)] IV. MONITORING AND REPORTING REQUIREMENTS 1. The Permittee shall conduct and report any Division required monitoring necessary to evaluate this facility's impact on groundwater and surface water. [15A NCAC 02T .0108(c)] 2. A Division -certified laboratory shall conduct all analyses for the required effluent, groundwater, and surface water parameters. [15A NCAC 02H .0800] 3. Flow through the treatment facility shall be continuously monitored, and daily flow values shall be reported on Form NDMR. Facilities with a permitted flow less than 10,000 GPD may estimate their flow from water usage records provided the water source is metered. [15A NCAC 02T .0105(k), 02T .0108(c)] 4. The Permittee shall monitor the treated effluent at the frequencies and locations for the parameters specified in Attachment A. [15A NCAC 02T .0108(c)] 5. The Permittee shall maintain records tracking the amount of effluent irrigated. These records shall include the following information for each irrigation site listed in Attachment B: a. Date of irrigation; b. Volume of effluent irrigated; c. Site irrigated; d. Length of time site is irrigated; e. Continuous weekly, monthly, and year-to-date hydraulic (inches/acre) loadings; f. Continuous monthly and year-to-date loadings for any non -hydraulic parameter specifically limited in Attachment B; g. Weather conditions; and h. Maintenance of cover crops. [15A NCAC 02T .0108(c)] 6. Freeboard (i.e., waste level to the lowest embankment elevation) in the 204,000 gallon treatment lagoon and the 204,000 storage lagoon shall be measured to the nearest inch or tenth of a foot, and recorded weekly. Weekly freeboard records shall be maintained for five years, and shall be made available to the Division upon request. [15A NCAC 02T .0108(c)] WQ0005681 Version 5.0 Shell Version 200201 Page 5 of 9 7. Three copies of all monitoring data (as specified in Conditions IV.3. and IVA.) on Form NDMR for each PPI and three copies of all operation and disposal records (as specified in Conditions IV.5. and IV.6.) on Form NDAR- I for every site in Attachment B shall be submitted on or before the last day of the following month. If no activities occurred during the monitoring month, monitoring reports are still required documenting the absence of the activity. All information shall be submitted to the following address: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 [15A NCAC 02T .0105(1)] 8. The Permittee shall maintain a record of all residuals removed from this facility. This record shall be maintained for five years, and shall be made available to the Division upon request. This record shall include: a. Name of the residuals hauler; b. Non -Discharge permit number authorizing the residuals disposal, or a letter from a municipality agreeing to accept the residuals; c. Date the residuals were hauled; and d. Volume of residuals removed. [15A NCAC 02T .0508(b)] 9. A maintenance log shall be kept at this facility. This log shall be maintained for five years, and shall be made available to the Division upon request. This log shall include: a. Date of flow measurement device calibration; b. Date of irrigation equipment calibration; c. Visual observations of the plant and plant site; and d. Record of preventative maintenance (e.g., changing of equipment, adjustments, testing, inspections, and cleanings, etc.). [15A NCAC 02T .0507(h)] 10. Monitoring wells MW-1, MW-2, and MW-4 shall be sampled at the frequencies and for the parameters specified in Attachment C. All mapping, well construction forms, well abandonment forms and monitoring data shall refer to the permit number and the well nomenclature as provided in Attachment C and Figure 1. [15A NCAC 02T .0105(m)] 11. Two copies of the monitoring well sampling and analysis results shall be submitted on a Compliance Monitoring Form (GW-59), along with attached copies of laboratory analyses, on or before the last working day of the month following the sampling month. The Compliance Monitoring Form (GW-59) shall include this permit number, the appropriate well identification number, and one GW-59a certification form shall be submitted with each set of sampling results. All information shall be submitted to the following address: Division of Water Resources Information Processing Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 [15A NCAC 02T .0105(m)] WQ0005681 Version 5.0 Shell Version 200201 Page 6 of 9 12. An annual representative soils analysis (i.e., Standard Soil Fertility Analysis) shall be conducted on each irrigation site listed in Attachment B. These results shall be maintained at the facility for five years, and shall be made available to the Division upon request. Each Standard Soil Fertility Analysis shall include the following parameters: Acidity Exchangeable Sodium Percentage Phosphorus Base Saturation (by calculation) Magnesium Potassium Calcium Manganese Sodium Cation Exchange Capacity Percent Humic Matter Zinc Copper pH [15A NCAC 02T .0108(c)] 13. Noncompliance Notification: The Permittee shall report to the Winston-Salem Regional Office, telephone number (336) 776-9800, within 24 hours of first knowledge of the following: a. Treatment of wastes abnormal in quantity or characteristic, including the known passage of a hazardous substance. b. Any process unit failure (e.g., mechanical, electrical, etc.) rendering the facility incapable of adequate wastewater treatment. c. Any facility failure resulting in a discharge to surface waters. d. Any time self -monitoring indicates the facility has gone out of compliance with its permit limitations. e. Ponding in or runoff from the irrigation sites. Emergencies requiring reporting outside normal business hours shall call the Division's Emergency Response personnel at telephone number (800) 662-7956, (800) 858-0368, or (919) 733-3300. All noncompliance notifications shall file a written report to the Winston-Salem Regional Office within five days of first knowledge of the occurrence, and this report shall outline the actions proposed or taken to ensure the problem does not recur. [15A NCAC 02T .0108(b)(1)(A)] V. INSPECTIONS 1. The Permittee shall perform inspections and maintenance to ensure proper operation of the wastewater treatment and irrigation facilities. [15A NCAC 02T .0507(i)] 2. The Permittee shall inspect the wastewater treatment and irrigation facilities to prevent malfunctions, facility deterioration, and operator errors that may result in discharges of wastes to the environment, threats to human health, or public nuisances. The Permittee shall maintain an inspection log that includes the date and time of inspection, observations made, and maintenance, repairs, or corrective actions taken. The Permittee shall maintain this inspection log for a period of five years from the date of the inspection, and this log shall be made available to the Division upon request. [15A NCAC 02T .0507(h), 02T .0507(i)] 3. Division authorized representatives may, upon presentation of credentials, enter and inspect any property, premises, or place related to the wastewater treatment and irrigation facilities permitted herein at any reasonable time for determining compliance with this permit. Division authorized representatives may inspect or copy records maintained under the terms and conditions of this permit, and may collect groundwater, surface water, or leachate samples. [G.S. 143-215.3(a)(2)] WQ0005681 Version 5.0 Shell Version 200201 Page 7 of 9 VI. GENERAL CONDITIONS 1. Failure to comply with the conditions and limitations contained herein may subject the Permittee to a Division enforcement action. [G.S. 143-215.6A, 143-215.613, 143-215.6C] 2. This permit is effective only with respect to the nature and volume of wastes described in the permit application, and Division -approved plans and specifications. [G.S. 143-215.1(d)] 3. Unless specifically requested and approved in this permit, there are no variances to administrative codes or general statutes governing the construction or operation of the facilities permitted herein. [15A NCAC 02T .0105(n)] 4. The issuance of this permit does not exempt the Permittee from complying with all statutes, rules, regulations, or ordinances that other jurisdictional government agencies (e.g., local, state, and federal) may require. [15A NCAC 02T .0105(c)(6)] 5. If the permitted facilities change ownership, or the Permittee changes their name, the Permittee shall submit a permit modification request on Division -approved forms. The Permittee shall comply with all terms and conditions of this permit until the permit is transferred to the successor -owner. [G.S. 143- 215.1(d3)] 6. The Permittee shall retain a set of Division -approved plans and specifications for the life of the facilities permitted herein. [15A NCAC 02T .0105(o)] 7. The Permittee shall maintain this permit until the proper closure of all facilities permitted herein, or until the facilities permitted herein are permitted by another authority. [15A NCAC 02T .01050)] 8. This permit is subject to revocation or modification upon 60-day notice from the Division Director, in whole or part for: a. violation of any terms or conditions of this permit or Administrative Code Title 15A Subchapter 02T; b. obtaining a permit by misrepresentation or failure to disclose all relevant facts; c. the Permittee's refusal to allow authorized Department employees upon presentation of credentials: I. to enter the Permittee's premises where a system is located or where any records are required to be kept; ii. to have access to any permit required documents and records; iii. to inspect any monitoring equipment or method as required in this permit; or iv. to sample any pollutants; d. the Permittee's failure to pay the annual fee for administering and compliance monitoring; or e. a Division determination that the conditions of this permit are in conflict with North Carolina Administrative Code or General Statutes. [15A NCAC 02T .0110] WQ0005681 Version 5.0 Shell Version 200201 Page 8 of 9 9. Unless the Division Director grants a variance, expansion of the facilities permitted herein shall not occur if any of the following apply: a. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has been convicted of environmental crimes under G.S. 143-215.6B, or under Federal law that would otherwise be prosecuted under G.S. 143-215.6B, and all appeals of this conviction have been abandoned or exhausted. b. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has previously abandoned a wastewater treatment facility without properly closing the facility. c. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid a civil penalty, and all appeals of this penalty have been abandoned or exhausted. d. The Permittee or any parent, subsidiary, or other affiliate of the Permittee is currently not compliant with any compliance schedule in a permit, settlement agreement, or order. e. The Permittee or any parent, subsidiary, or other affiliate of the Permittee has not paid an annual fee. [15A NCAC 02T .0120(b), 02T .0120(d)] 10. This permit shall not be renewed if the Permittee or any affiliation has not paid the required annual fee. [15A NCAC 02T .0120(c)] Permit issued this the 27 h day of May 2020 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION S. Daniel Smith, Director Division of Water Resources By Authority of the Environmental Management Commission Permit Number WQ0005681 WQ0005681 Version 5.0 Shell Version 200201 Page 9 of 9 THIS PAGE BLANK ATTACHMENT A — LIMITATIONS AND MONITORING REQUIREMENTS PPI 001— WWTP Effluent Permit Number: WQ0005681 Version: 5.0 EFFLUENT CHARACTERISTICS EFFLUENT LIMITS MONITORING REQUIREMENTS PCS Code Parameter Description Units of Measure Monthly Monthly Average Geometric Mean Daily Minimum Daily Maximum Measurement Frequency Sample Type 00310 BOD, 5-Day (20 °C) mg/L 3 x Year' Grab 00916 Calcium, Total (as Ca) mg/L 3 x Year' Grab 00940 Chloride (as Cl) mg/L Annually 2 Grab 50060 Chlorine, Total Residual mg/L Weekly Grab 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL 3 x Year' Grab 50050 Flow, in Conduit or thru Treatment Plant GPD 13,000 Continuous Recorder 00927 Magnesium, Total (as Mg) mg/L 3 x Year' Grab 00610 Nitrogen, Ammonia Total (as N) mg/L 3 x Year' Grab 00625 Nitrogen, Kjeldahl, Total (as N) mg/L 3 x Year' Grab 00620 Nitrogen, Nitrate Total (as N) mg/L 3 x Year' Grab 00600 Nitrogen, Total (as N) mg/L 3 x Year' Calculated 00400 pH su Weekly Grab 00665 Phosphorus, Total (as P) mg/L 3 x Year' Grab 00931 Sodium Adsorption Ratio Ratio 3 x Year' Calculated 00929 Sodium, Total (as Na) mg/L 3 x Year' Grab 70300 Solids, Total Dissolved — 180 °C mg/L Annually 2 Grab 00530 Solids, Total Suspended mg/L 3 x Year' Grab 1. 3 x Year sampling shall be conducted in March, July, and November. 2. Annual sampling shall be conducted in November. WQ0005681 Version 5.0 Attachment A Page 1 of 1 THIS PAGE BLANK ATTACHMENT B — APPROVED LAND APPLICATION SITES AND LIMITATIONS Pilgrim's Pride Corporation — Pilgrim's Pride — Staley WWTP Permit Number: WQ0005681 Version: 5.0 IRRIGATION AREA INFORMATION APPLICATION LIMITATIONS Net Dominant Hourly Yearly Field Owner County Latitude Longitude Parameter Units Acreage Soil Series Rate Max 1 Pilgrim's Pride Corporation Randolph 35.811353' -79.559482' 6.27 GeB2 - Georgeoville silty clay 01284 — Non -Discharge Application Rate 0.30 35.88 inches loam, 2-8 /o slopes Totals 6.27 WQ0005681 Version 5.0 Attachment B Page 1 of 1 THIS PAGE BLANK ATTACHMENT C — GROUNDWATER MONITORING AND LIMITATIONS Monitoring Wells: MW-1, MW-2, and MW-4 Permit Number: WQ0005681 Version: 5.0 GROUNDWATER CHARACTERISTICS GROUNDWATER STANDARDS MONITORING REQUIREMENTS PCS Code Parameter Description Daily Maximum Frequency Measurement Sample Type Footnotes 00680 Carbon, Tot Organic (TOC) mg/L Annually Grab 1,6 00940 Chloride (as Cl) 250 mg/L Annually Grab 1 31616 Coliform, Fecal MF, M-FC Broth, 44.5 °C #/100 mL Annually Grab 1 00610 Nitrogen, Ammonia Total (as N) 1.5 mg/L Annually Grab 1 00620 Nitrogen, Nitrate Total (as N) 10 mg/L Annually Grab 1 00400 pH 6.5-8.5 su Annually Grab 1,2 00665 Phosphorus, Total (as P) mg/L Annually Grab 1 70300 Solids, Total Dissolved - 180 °C 500 mg/L Annually Grab 1 82546 Water Level, Distance from measuring point feet Annually Calculated 1, 2, 3 1. Annual monitoring shall be conducted in November. 2. The measurement of water levels shall be made prior to purging the wells. The depth to water in each well shall be measured from the surveyed point on the top of the casing. The measurement of pH shall be made after purging and prior to sampling for the remaining parameters. 3. The measuring points (top of well casing) of all monitoring wells shall be surveyed to provide the relative elevation of the measuring point for each monitoring well. The measuring points (top of casing) of all monitoring wells shall be surveyed relative to a common datum. 4. If TOC concentrations greater than 10 mg/L are detected in any downgradient monitoring well, additional sampling and analysis shall be conducted to identify the individual constituents comprising this TOC concentration. If the TOC concentration as measured in the background monitor well exceeds 10 mg/L, this concentration will be taken to represent the naturally occurring TOC concentration. Any exceedances of this naturally occurring TOC concentration in the downgradient wells shall be subject to the additional sampling and analysis as described above. 5. Monitoring wells shall be reported consistent with the nomenclature and location information provided in Figure 1 and this attachment. WQ0005681 Version 5.0 Attachment C Page 1 of 1 WQ0005681 Pilgrim's Pride Corporation Staley Hatchery and Feed Mill WWTF L Legend Facility Well Irrigation Field Monitoring Well • Private Well Storage Lagoon Stormwater Outfall Treatment Lagoon WWTF -W-yh soli i