Loading...
HomeMy WebLinkAboutWQ0031498_Sewer Extension_20070320•,cACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: (to be completed by DWQ) 1 1. Owner. la. Town of Aberdeen Full Legal Name (company, municipality, HOA, utility, etc.) 1 b. Bill Zell, Town Manager Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) 1c. The legal entity who will own this system is: ❑ id � Indivual ❑ Federal ® Municipality ❑ State/County ❑Private Partnership ❑Corporation ❑Other (specify): 0 Id. PO Box 785 - 115 N. Poplar Street Ile. Aberdeen Z Mailing Address City If. NC Z State 1 g 28315 --- ---.. - -- - Zip Code ----- _ 4-1115 1 i. 910-944-7459 _ _._..-- � 1j. ze111115Qalltel.net Q Telephone Facsimile E-mail (� 2. Project (Facility) Information: -- -- — --- - ---- _ — --- -- - - ----- a. oodGreen Subdivision Phase 5A - - - - - 1 a � 2b. Moore Brief Project Name (permit will refer to this name ) County Where Project is Located Qj3. Contact Person: - Q 3a. David T. Upchurch, P.E. Hobbs, Upchurch & Associates Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. 910-692-5616 3c. dupchurch@hobbsupchurch.com Phone Number E-mail 1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified Information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been Included in the original permit. 2. Owner is ® Public (skip to Item 8(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) ❑ RetainingOwnership ' p (i.e. store, church, single office, etc.) or ! ❑Public Utility (Instruction 111) Z ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction IV) Q ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) Q3. Moore County Public Utilities -- ` - ------ Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project � 4a. Moore County Wastewater Treatment Plant � 4b. NPDES NC 0037508 nm NJHOBBS, UPCHU CH & ASSOCIA?£,S, P.A. B�T � �� 71 CONSULTING ENGINEERS P.O. BOX 1737, 300 S.W. BROAD STREET Branch Banking and Trust Company SOUTHERN PINES. NC 28388 66-112/531 (910)692-5616 Lctly Four hundred and no / 100 Dollars DATE AMOUNT 3/13/2007 $400.00 C 0 HE ER N . C . DENR .per. V ID AFTER 90 DAYS I �J NC AUTHORIZED SIGNATURE ..■ FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 1 of W A rFq *. State of North Carolina 1.JJ Department of Environment and Natural Resources oY OQ Division of Water Quality L FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure sewers systems are not to be included as part of this application package) INSTRUCTIONS: Indicate that you have included/addressed the following list of required application package items by checking the space provided next to each applicable item. Failure to submit all required items will lead to your application being returned as incomplete. This form may be photocopied for use as an original. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans andspecifications unless you res and NO to Item B(12). Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). Checks shall be dated within 90 days of application submittal. ❑ III. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2a) of this application. ❑ IV. Operational Agreements — Submit one original and two copies of a properly executed operational agreement if the sewer extension is permitted by a private applicant and will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be sold to another entity. If the applicant is a homeowners' association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF THE PROJECT WILL BE TURNED OVER TO A MUNICIPALITY, FORM DEV 02/03 IS REQUIRED. Ef"V. Flow Acceptance Letters — If the owner of the downstream sewers and/or WWTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and WWTF, if different. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. 211V*l. Map — Submit an 8.5-inch by 11-inch COLOR copy of the portion of a 7.5-minute USGS Topographic Map along with this form. The map should identify the entire project area location as well as the closest downslope surface waters as clearly as possible. Each map portion must be labeled with the map name and number, the identified location of the sewer line and pump stations, and be of clear and reproducible quality. For instance, if the project involves 4 miles of interceptor sewer that traverses over or near several different waterbodies (or counties, basins, etc.), the map should have location ID's shown for each different waterbody (where the sewer line is within 100 feet of such waterbody - see Instruction VII). This location ID is self chosen and used to cross reference the location in Section C of the permit application. eVII. Stream Classifications — Section C • If any portion of the project is within 100 feet of any down slope surface water, Section C must be completed for the pertinent sections. • If the entire project area is a minimum of 100 feet away from any down slope surface waters BUT there is a pump station involved where a history of power outage is to be used to provide adequate design storage instead of dual feed or permanent or portable generator, Section C must be completed to demonstrate that the closest down slope surface water is Class C (see 15A NCAC 2H .0219(h)(3)(D)). • Use the guidance document entitled, "Determining Watershed Classifications for Form FTA 02/03 (Fast -Track Sewer Systems)" available from http://h2o.enr.state.nc.us/percs or by contacting the appropriate regional office. trTA nl in) n___ FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS • PAGE 2 ❑ Vill. Environmental Assessments — If this project is subject to an Environmental Assessment (EA) [15A NCAC 01C], this application can not be used. Send the project application on Form PSFMGSA 10/99 to the PERCS Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Applications can not be accepted until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. Rr IX. Certifications — Section D The application must be certified by both the applicant and a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1 b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC 2H .0200, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. Certification by a PE who is unfamiliar with these documents is subject to NC Board referral. ❑ X. Downstream Sewer & Wastewater Treatment Plant Capacity The applicant has assured downstream pipe, pump station and treatment plant capacity. The addition of new sources of wastewater from this project has been evaluated along the route to the receiving treatment plant. The flow from this project will not cause capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving wastewater treatment plant. If the applicant is not the owner of the downstream sewer or receiving treatment plant, submittal of flow acceptance letters) indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). THE COMPLETED FTA02/03 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND$400 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Swannanoa, North Carolina 28778 Avery, Buncombe, Burke, Caldwell, Cherokee, Clay, Graham, Haywood, (828) 296-4500 (828) 299-7043 Fax Henderson, Jackson, Macon, Madison, McDowell, Mitchell, Polk, Rutherford, Fayetteville Regional OfficeSwain, g Street Suite 714 Trans Ivania, Yance Anson, Bladen, Cumberland, Hamett,ville, Z225en North Carolina 28301 Hoke, Montgomery, Moore, Robeson,6-1541 6-0707 Fax Richmond, Sampson, Scotland Mooresville Regional Office .Center Avenue, Suite 301 Mooresville, North Carolina 28115 Alexander, Cabarrus, Catawba, Cleveland, Gaston, Iredell, Lincoln, (704) 663-1699 (704) 663-6040 Fax Mecklenburg, Rowan, Stanly, Union Raleigh Regional Office 1628 Mail Service Center Raleigh, North Carolina 27699-1628 Chatham, Durham, Edgecombe, Franklin, (919) 571-4700 Granville, Halifax, Johnston, Lee, Nash, Northampton, Orange, Person, Vance, Washington Regional Office 919 571-4718 Fax 943 Washington Square Mall Wake, Warren, Wilson Washington, North Carolina 27889 Beaufort, Bertie, Camden, Chowan, Craven, Currituck, Dare, Gates, Greene, (252) 946-6481 (252) 975-3716 Fax Hertford, Hyde, Jones, Lenoir, Martin, Pamlico, Pasquotank, Perquimans, Pitt, Wilmington Regional Office 9 9 127 Cardinal Drive Extension Tyrrell, Washington, Wayne Wilmington, North Carolina 28405 (910) 395-3900 Brunswick, Carteret, Columbus, Duplin, New Hanover, Onslow, Pender (910) 350-2004 Fax Winston-Salem Regional Office 585 Waughtown Street Winston-Salem, North Carolina 27107 ny, Ashe, Caswell, A=Randolph, (336) 771-4600 Dorsyth, Guilford, Rolph, Stokes, Surry, (336) 771-4631 Fax WYadkin For more information, visit our web site at http.//h2o. enr state. nc. us/peres/ PTA niim De I nA/nC i FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 Z C Q C U. _Z Z O V J a a USE THE TAB KEY TO MOVE FROM FIELD TO FIELDI Application Number: y�Q0031468 —------- ___ __ (to be completed by DWO) 1. Owner.• — 1 a. Town of Aberdeen Full Legal Name (company, municipality, HOA, utility, etc.) 1 b. Bill Zell, Town Manager Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal ® Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify): Id. PO Box 785 - 115 N. Poplar Street 1 e. Aberdeen Mailing Address City 1f. NC 1g State 1 h. 910-944-1115 1 i. 910-944-7459 1j Telephone Facsimile Project (Facility) Information: 2a. WoodGreen Subdivision Phase-5A 2b Brief Project Name (permit will refer to this name) 3 Contact Person: ---- 3a. David T. Upchurch P.E. Hobbs Upchurch & As 3b. sociates Name and Affiliation of Someone Who Can Answer Questions About this Application 910-692-5616 Phone Number 3c. dupchurch h com ( g permit) If Modification, Permit No.: I. Project is ®New El Modification of an existing For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only Include the modified Information In this permit application - do not duplicate project Information in B(7) and B(10-11) that has already been included In the original permit. j 2. Owner is ® Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Public Utility (Instruction III) 0 Z ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction IV) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) Q3. Moore County Public Utilities Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Moore County Wastewater Treatment Plant 4b. NPDES NC 0037508 O Name of WWTF WWTF Permit No. I.L. 5a. Town of Aberdeen 5b. 8" ®Gravity '5c. Z X Z Owner of Downstream Sewer ;Receiving Sewer Size !❑ Force Main Permit Number of Downstream Sewer (if known) �— 6. The origin of this wastewater is (check all that apply): ® Residential Subdivision ❑ Car Wash W ❑ Apartments/Condominiums El Institution a ❑ Mobile Home Park El Hospital 100 % Domestic/Commercial El School ❑ Restaurant ❑ Church % Industrial m El Nursing Home Office _ ❑ Other (specify): % Other (specify): 7. Volume of wastewater to be allocated for this particular project: 2,520 gallons per day _--*Do not include previously permitted allocations 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected I PTA nIinll n _. nA Inf FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(1) for Item B(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). 7 single family homes @ 360 GPD = 2,520 GPD I j 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) i Size (Inches) Length (feet) Gravity or Force Main (use the pull down menu) 8609 Gravity W Z 1= Z O ENTER TOTAL LINE LENGTH IN MILES 0.11 11_ Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Z Location ID Power Reliability Option (self chosen -as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator WATS; 3• Q plans for cross-reference) (MGD) GPM @ TDH portable generator w/telemetry; 4-wet well storage) _._-. LA. Z _ _ _- F- 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? W ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and Indicate why a a variance Is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS adPERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have th e following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ® No ❑ N/A j Sedimentation and Erosion Control Plan? ❑ Yes ❑ No ® N/A Stormwater? ❑ Yes ❑ No ® N/A 14. Does this project involve aerial lines or siphons? Check if yes: ❑ These lines will be considered hiah orioritv and must be checked once every six months 15. Does this project have gravity sewer lines designed at minimum slopes? Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA 02/03 - Rev. 3 04105 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS • PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality Z regional office (see instructions for addresses) OR indicate the following: O 0 ® A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope i Q waterbody; AND, (,� ® A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability LL option for any pump station near a Class C down slope waterbody. yLocation ID on Map (self chosen - as shown on Name of map for cross-reference) Waterbody C� 1 Aberdeeen Creek W F- U) d rd� Waterbody Stream Waterbody i County River Basin Index Classification i Moore Lumber 14-2-11-(6) C Submit the 8.5" x 11" COLOR topographic map as required In Instruction VI regardless of whether a classification is providedl 1. Applicant's Certification: I attest that this application for WoodGreen Subdivision Phase-5A has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that/fall required supporting documentation and that are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violatlo 1 a. Signing Officiarfignature 2. Professional Engineer's Certification: 17107 Date 1, David Upchurch, P.E. attest that this application for WoodGreen Subdivision Phase-5A has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting I documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain Portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design.i Note: In accordance with NC General Statutes 143-215.6A and 143-215.68, an y person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. David Upchurch P.E.`CA Professional Engineer Name" 2b. Hobbs, Upchurch $Associates, P.A. Sf7< `* Engineering Firm 2c. P.O. Box 1737 SE r Mailing Address � 2d. Southern Pines 2e. NC 2f. 28388 �� < City State Zip„�� 2g. 910-692-5616 2h. 910-692-7342 2i. dpchurch@hobbsupchurch com E-mail ,+►� Telephone Facsimile r��� ----- ---- -- --- - -- -- ---- ----- Seal, Signature 8 Date FTA 07/1)1 - V.- -2 n/iinc N „00'0 .9£0 N „00'0 80 .S£0 N „00'0 LO .WO n ••\• �.' S•-a•.\ r � tl ' _ �' ♦ G� : .. ._' ' � Q' t'r3 , • AI • —.--i-r .�'''i, .. >s (�� �. Jt `�' 0 a0 u cc LD to (\� �7 i/ i ..,• —J s4 / �, fin. \� NO••a. X., `` + � /�� I ` - It /3 . P 33 �`O .S •7 � � •' �, t+: I �1 �1 M9IN,..r• •ayws. \ l i •,( �/ �/s>ps�•�Nrrsr b , 3 / + R� V ♦ 1 J l -0 " q . t+1 `{ �t � r 5:�. �'\ I r 11/ 1 44^ f�., ��.� 1 dab• a�i.��'�• �`'.• �/ (' .�i ``NN. ljwlS9,��w= ar +lye' �t•fJ - /�'• , (( \� ewr.\ � • Ay i 6 ♦ ^M}' _ 00 ft ''••���,CsJ \,a '1.•� wso Q�.�� iw y r nw/l 4�`t�-•� jr —_`_ J N „00'0 60 AM N „00"0 90 .9£0 N .00.0 L0.9£0 cl ri 1'. (). BOX 1y17 Carthage, North Carolina March 14, 2007 Mr. Lee Parris Hobbs, Upchurch & Associates P O BOX 1737 Southern Pines NC 28388 Dear Mr. Parris County of Moore Public Works IVIV W. i11 tit V 11C.C]OV C�JNTV OF M0�9F 0 naa NORTN :Qom MAR 16 2007 (910)947-6315 (Telephone) (910)947-1992 (Facsimile) RE: Flow Acceptance letter for WoodGreen Subdivision, Phase 5A, Aberdeen, NC. HUA No. AB0608 The Moore County Water Pollution Control Facility, NPDES # NC 0037508, presently has sufficient capacity available to conditionally accept up to 2,520 gallons per day from the above referenced project. This letter does not reflect the capacity of the immediate collection system owned and operated by the Town of Aberdeen This project will be required to comply with all specifications and requirements of the Town of Aberdeen, NC. and AWWA Standards. Upon completion of the referenced project, the applicant's engineer is to provide our office with the following items: 1. Certification of Completion. 2. Complete set of As -Built drawings. If you have any questions or comments please call me at (910) 947-6315. Property Management Public Utilities Solid Waste Wastewater Treatment Plant Ph - (910)947-2301 Ph - (910)947-6315 Ph - (910)947-3637 Ph - (910)281-3146 Fax - (910)947-2304 Fax - (910)947-1992 Fax - (910)947-1992 Fax - (910)281-2047 Flow Acceptance, Wood Green, Aberdeen March 14, 2007 Page 2 Sincerely, MOORE C PUBL WORKS Lex K ly, P.E. County Engineer Cc: Mr. Delmo Frye, WWTP Superintendent Mr. Ricky Monroe, Public Works Director, Town of Aberdeen Mr. Giles Hopkins, Planning Director, Town of Aberdeen