Loading...
HomeMy WebLinkAbout20200679 Ver 1_2020.03.27 JoCo 385 Issued For Permit NFC Plan Set_20200521I Wvjc■aI STATE MAP NOT TO SCALE PROJECT NAME: JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS OWNER: JOHNSTON COUNTY PUBLIC UTILITIES DISTRICT AND COUNTY BOARD OF COMMISSIONERS: TED G. GODWIN, CHAIRMAN CHAD M. STEWART, VICE-CHAIRMAN JEFFREY P. CARVER LARRY WOOD TONY BRASWELL PATRICK E. HARRIS R.S. "BUTCH" LAWTER. JR. MANAGER RICK J. HESTER ...AROR*111 USlpy9� 9 SEA 46 .......( MCBa4&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com PROJECT INFORMATION JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS PROJO NO. 0035811111111111110141 MARCH 27,2020 ISSUED FOR PERMITTING NOT FOR CONSTRUCTION Sheet List Table Sheet Number Sheet Title GENERAL G1 COVER SHEET G2 GENERAL NOTES AND LEGEND G3 SHEET INDEX MAP AND SURVEY CONTROL CIVIL C1 FIRE DEPT RD STA. 1+00 - STA. 11+53 C2 FIRE DEPT RD STA. 11+53 - STA. 16+24 C3 POWHATAN RD STA. 20+00 - STA. 30+42 C4 POWHATAN RD STA. 30+42 - STA. 40+55 C5 POWHATAN RD STA. 40+55 - STA. 51+25 C6 POWHATAN RD STA. 51+25 - STA. 61+65 C7 POWHATAN RD STA. 61+65 - STA. 72+05 C8 POWHATAN RD STA. 72+05 - STA. 82+45 C9 POWHATAN RD STA. 82+45 - STA. 85+34 C10 GORDON RD STA. 100+00 - STA. 109+40 C11 GORDON RD STA. 109+40 - STA. 118+80 C12 GORDON RD STA. 118+80 - STA. 128+20 C13 GORDON RD STA. 128+20 - STA. 137+60 C14 GORDON RD STA. 137+60 - STA. 147+08 C15 GORDON RD STA. 147+08 - STA. 156+48 C16 GORDON RD STA. 156+48 - STA. 165+88 C17 GORDON RD STA. 165+88 - STA. 175+23 C18 GORDON RD STA. 175+23 - STA. 184+68 C19 GORDON RD STA. 184+68 - STA. 194+45 C20 GORDON RD STA. 194+45 - STA. 205.57 C21 GORDON RD STA. 205+57 - STA. 213+90 C22 GORDON RD STA. 213+90 - STA. 221+82 C23 GORDON RD STA. 221+82 - STA. 231+31 C24 GORDON RD & US HWY 70 STA. 231+31 - STA. 241+22 C25 US HWY 70 STA. 241+22 - STA. 250+60 C26 US HWY 70 STA. 250+60 - STA. 259+84 C27 US HWY 70 STA. 260+84 - STA. 269+26 C28 US HWY 70 STA. 270+26 - STA. 277+30 DETAILS D1 JOHNSTON COUNTY STANDARD WATER DETAILS D2 JOHNSTON COUNTY STANDARD WATER DETAILS D3 JOHNSTON COUNTY STANDARD WATER DETAILS D4 PAVEMENT REPAIR & MISC DETAILS D5 EROSION AND SEDIMENT CONTROL DETAILS D6 EROSION AND SEDIMENT CONTROL DETAILS D7 EROSION AND SEDIMENT CONTROL DETAILS D8 EROSION AND SEDIMENT CONTROL DETAILS Know what's below. Call before you dig. SHEET INDEX H 2 w O Z 0 U) 2 Q U) W IJ7 00 Cr) Z Z) O U z O U) Z O TM- O i L{) M O O O Z O 01-1 IL I:\00358\0141\WATER\80-DRAWINGS\GENERAL\G.01-003580141-J000385-COVER.DWG - - - - 03/27/2020 10:14:21 DAVID HAMMOND 1 1 ABBREVIATIONS A AIR AC ASBESTOS CEMENT AL OR ALUM ALUMINUM ASPH ASPHALT ARV AIR RELEASE VALVE BC BACK OF CURB BFV BUTTERFLY VALVE BLD BLIND BO BLOW OFF VALVE BV BALL VALVE CAN CABLE TELEVISION CB CATCH BASIN C&G CURB AND GUTTER CI CURB INLET C/L, CENTERLINE CMP CORRUGATED METAL PIPE CMU CONCRETE MASONRY UNIT CO CLEAN OUT CON CONCENTRIC CONIC CONCRETE CPLG COUPLING CPP CORRUGATED PLASTIC PIPE CV CHECK VALVE D DRAIN DI DROP INLET / DUCTILE IRON DIP DUCTILE IRON PIPE D/W DRIVE WAY DWG DRAWING EL OR ELEV ELEVATION EOG EDGE OF GRAVEL EP, EDP EDGE OF PAVEMENT EX EXISTING EXP EXPANSION LP LIGHT POLE FICA FLANGE COUPLING ADAPTER FD FLOOR DRAIN FFE FINISHED FLOOR ELEVATION FH FIRE HYDRANT FIN FINISHED FHA FIRE HYDRANT ASSEMBLY FLG FLANGE FLEX FLEXIBLE FLR FLOOR FM FORCE MAIN FRP FIBERGLASS REINFORCED PIPE FO FIBER OPTIC FOT FLAT ON TOP GL GUTTER LINE GRAV GRAVEL GTS GAS TEST STATION GV GATE VALVE GW GUY WIRE HDPE HIGH -DENSITY POLYETHYLENE HP HIGH POINT HWL HIGH WATER LEVEL INV INVERT ELEVATION IPF IRON POST FOUND JB JUNCTION BOX JT JOINT LF LINEAR FEET LOD LIMITS OF DISTURBANCE LP LOW POINT LR LONG RADIUS LWL LOW WATER LEVEL MB MAIL BOX MAX MAXIMUM MH MANHOLE MIN MINIMUM MJ MECHANICAL JOINT N.C. NORMALLY CLOSED N.O. NORMALLY OPEN NIC NOT IN CONTRACT NWL NORMAL WATER LEVEL OHE/OE OVER HEAD ELECTRIC O/F OVERFLOW OU OVER HEAD UTILITIES PE PLAIN END POL POLYMER PP POWER POLE PRV PRESSURE REDUCING VALVE PTFE POLYTETRAFLUOROETHYLENE PV PLUG VALVE PVC POLY VINYL CHLORIDE PW POTABLE WATER RCP REINFORCED CONCRETE PIPE REC PER RECORD RED REDUCER RFCA RESTRAINED FLANGE COUPLING ADAPTER RJ RESTRAINED JOINT R/W, ROW RIGHT OF WAY SDMH STORM DRAIN MANHOLE SS SANITARY SEWER S.S. STAINLESS STEEL SSMH SANITARY SEWER MANHOLE STA STATION SUE SUBSURFACE UTILITY ENGINEERING S/W SIDE WALK SVC SERVICE TBM TEMPORARY BENCH MARK TIC TERRA COTTA TOB TOP OF BANK TOC TOP OF CONCRETE TOG TOP OF GRATING TOS TOP OF SLAB TOW TOP OF WALL TH TEST HOLE TPF TREE PROTECTION FENCE TYP TYPICAL LINO UNLESS NOTED OTHERWISE UNK UNKNOWN VCP VITRIFIED CLAY PIPE WL WATER LINE WM IWATER METER WV IWATER VALVE WWF IWELDED WIRE FABRIC YI IYARD INLET 3 FEXISTING LINE LEGEND DESCRIPTION UNETYPE UNDERGROUND CABLE TV - - -TV- - - - -TV(R)- - - -E- - - - -E(R) - - - - - -Fo - --FO(R)- - - - - -FM- - - - - - FM(R)- - - - - -G- - - - - -G(R)- - - ou - - -R- - - - - -R(R)- - - ___SS___ - - - SS(R)- - - UNDERGROUND PER RECORD CABLE TV UNDERGROUND ELECTRIC PER RECORD UNDERGROUND ELECTRIC UDERGROUND FIBER OPTIC PER RECORD UNDERGROUND FIBER OPTIC SANITARY SEWER FORCEMAIN PER RECORD SANITARY SEWER FORCE MAIN UNDERGROUND GAS UNDERGROUND PER RECORD GAS OVER HEAD UTILITIES RECLAIMED WATER LINE PER RECORD RECLAIMED WATER LINE GRAVITY SANITARY SEWER PER RECORD GRAVITY SANITARY SEWER STORM DRAINAGE -r- - - - - -T(R)- - - -D- - - ---w--- UNDERGROUND TELEPHONE UNDERGROUND PER RECORD TELEPHONE UNDERGROUND UNKNOWN WATER LINE PER RECORD WATER LINEFENCE GUARD GUARD RAIL e e BACK OF CURB EASEMENT EDGE OF GRAVEL EDGE OF PAVEMENT - - - PROPERTY LINE RIGHT OF WAY ROAD CENTER LINE -100FP- - - - -Z2- - - - - ---�--- 100 YEAR FLOODPLAIN DITCH MAJOR CONTOUR MINOR CONTOUR RIPARIAN BUFFER ZONE 1- RIPARIAN BUFFER ZONE 2 TOP OF BANK TREELINE WATERCOURSE q- WETLAND BOUNDARY REV.NO. DESCRIPTION DATE D j ISSUED FOR PERMITTING - NOT FOR CONSTRUCTION 03127/20 C 90%DESIGN- NOT FOR CONSTRUCTION 03H 920 R 60% DESIGN -NOT FOR CONSTRUCTION 02107/20 A 30% DESIGN -NOT FOR CONSTRUCTION 11115/19 REVISIONS 8 1 GENERAL NOTES GENERAL/ CONSTRUCTION NOTES 1. ALL UNDERGROUND UTILITIES ARE APPROXIMATE LOCATION UNLESS OTHERWISE NOTED. CONTRACTOR TO VERIFY SIZE, DEPTH, LOCATION AND MATERIAL OF ALL EXISTING UTILITIES PRIOR TO THE START OF CONSTRUCTION. CONTRACTOR SHALL CONTACT 'N.C. ONE CALL CENTER' MIN. 48 HOURS PRIOR TO THE START OF CONSTRUCTION (1-800-632-4949). 2. THE UNDERGROUND UTILITIES INDICATED ON THE PLANS HAVE BEEN TAKEN FROM INFORMATION MADE AVAILABLE FROM THE VARIOUS UTILITY OWNERS. THIS INFORMATION IS NOT INCLUSIVE OF ALL EXISTING UNDERGROUND UTILITIES AND CABLES. THE CONTRACTOR IS ADVISED THAT ADDITIONAL UNDERGROUND UTILITIES AND CABLES MAY EXIST WHICH ARE NOT SHOWN ON THE PLANS. PLEASE BE ADVISED THAT THE UNDERGROUND UTILITIES AND CABLES COULD CONFLICT WITH THE WATER MAIN CONSTRUCTION AS SHOWN. THE OWNER WILL WORK WITH THE CONTRACTOR TO REALIGN THE WATER MAIN AND APPURTENANCES TO MINIMIZE CONFLICTS. THE OWNER WILL NOT CONSIDER REQUEST FOR ADDITIONAL COMPENSATION DUE TO THE PRESENCE OF CONFLICTING UTILITIES AND CABLES THAT ARE NOT SHOWN ON THE PLANS. REFER TO SPC-23 OF SECTION 18-SPECIAL PROJECT CONDITIONS FOR MORE INFORMATION. 3. CONTRACTOR SHALL COMPLY WITH APPROVED N.C.D.O.T. AND NORTH CAROLINA RAILROAD COMPANY ENCROACHMENT AGREEMENTS WHILE WORKING WITHIN THE AGENCIES RIGHT-OF-WAYS. 4. CONTRACTOR TO INSTALL EROSION CONTROL MEASURES PRIOR TO THE START OF CONSTRUCTION. 5. ACCESS TO EACH RESIDENCE AND BUSINESS SHALL BE MAINTAINED AT ALL TIMES. 6. ALL DISTURBED AREAS SHALL BE RESEEDED WITH LIKE GRASSES IN RESIDENTIAL AREAS. DISTURBED AREAS LEFT INACTIVE BETWEEN ANY PHASE OF GRADING SHALL BE TEMPORARILY SEEDED WITHIN 7 WORKING DAYS OR 14 CALENDAR DAYS, WHICHEVER IS SHORTER. PROVISIONS FOR PERMANENT GROUND COVER MUST BE ACCOMPLISHED ON EXPOSED SLOPES WITHIN 21 CALENDAR DAYS, AND IN REMAINING AREAS WITHIN 15 WORKING DAYS OR 90 CALENDAR DAYS, WHICHEVER IS SHORTER. 7. TRAFFIC FLOW SHALL BE MAINTAINED, WITH A MINIMUM OF ONE LANE OPEN, AT ALL TIMES DURING CONSTRUCTION. 8. REPAIR AND REPLACEMENT OF HEADWALLS, MAILBOXES, DRIVEWAY CULVERTS, DRAIN PIPES, ROOF LEADERS AND DRAINS, RETAINING WALLS, SIGNS, LANDSCAPING ETC. REQUIRED DUE BUT NOT SPECIFICALLY LISTED ON THE BID FORM TO CONSTRUCTION ACTIVITIES SHALL BE INCLUDED IN THE COST OF THE PIPE. 9. CONTRACTOR SHALL REWORK ALL GRAVEL, CONCRETE, AND PAVED DRIVEWAYS WITH LIKE MATERIAL IN ACCORDANCE WITH THE SPECIFICATIONS. ALL STREETS AND DRIVEWAYS SHALL BE SWEPT CLEAN OF DIRT AND DEBRIS AT THE END OF EACH WORKING DAY. 10. CONTRACTOR SHALL COORDINATE WITH JOHNSTON COUNTY FOR ANY DISRUPTIONS OF THE NORMAL OPERATION OF WATER AND SEWER SERVICES. 11. CONTRACTOR SHALL NOTIFY APPROPRIATE PERSON AND AGENCIES TWO WEEKS PRIOR TO THE BEGINNING OF CONSTRUCTION: A. DIRECTOR OF UTILITIES, JOHNSTON COUNTY. CHANDRA FARMER, PE, TELEPHONE NO. 919-209-8333. 13. CONTRACTOR SHALL PLACE ALL SPOIL MATERIAL ON THE UPHILL SIDE AWAY FROM ALL ROAD SIDE DITCHES, CREEKS, AND WATER COURSES DURING CONSTRUCTION. ALL EXCAVATION SHALL BE BACKFILLED AND ROADWAYS SWEPT, AT THE END OF EACH WORK DAY. 14. ALL DISTURBED DITCH LINES SHALL BE RESHAPED, RESEEDED, MULCHED, AND TACK COAT APPLIED. WATTLES TO BE PLACED IN DITCHES AT THE END OF EACH WORK DAY. INSTALL WATTLES AT LOWER REACH OF DISTURBANCE AT THE END OF EACH WORK DAY. 15. INSTALL SILT FENCE PERPENDICULAR TO NEW WATER MAIN AT CULVERTS UNTIL RIP -RAP IS INSTALLED OR GRASS STABILIZED. 16.INSTALL 10 LINEAR FEET OF STRAW W/ NET AT OUTLET OF ALL DRIVEWAY PIPES AT AREAS WHERE DITCH IS DENUDED, UNLESS OTHERWISE SHOWN. v v,NnJ/ & REED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com JOHNSTON COUNTY DEPARTMENT OF UTILITIES 17. ALL DEWATERING SHALL BE DONE THROUGH SEDIMENT FILTER BAGS AS SHOWN ON THE EROSION AND SEDIMENT CONTROL PLAN DETAILS. 18. IF BLASTING IS NECESSARY, CONTRACTOR SHALL INSTALL EROSION AND SEDIMENTATION CONTROL DEVICES PER PLAN PRIOR TO DISTURBANCE. 19. LOCATIONS OF EROSION AND SEDIMENTATION CONTROL IN LAYDOWN AND STAGING AREAS MUST BE MAINTAINED WITHIN THE EXISTING ROAD RIGHTS -OF -WAY OR EASEMENTS, UNLESS THE CONTRACTOR OBTAINS WRITTEN PERMISSION FROM A PROPERTY OWNER TO USE THAT OWNER'S PRIVATE PROPERTY FOR THESE PURPOSES. 20. CONTRACTOR SHALL INSTALL THE WATER MAIN WITHIN NCDOT ROW, THE NORTH CAROLINA RAILROAD COMPANY ROW, TOWN OF WILSON'S MILLS ROW, OR THE EASEMENTS SHOWN. 21. CONTRACTOR SHALL INSTALL CONCRETE BLOCKING AT EVERY MJ FITTING AND INCLUDE THIS COST IN THE PRICE OF THE FITTINGS. 22.CONTRACTOR SHALL ROD FITTINGS TO THE STEEL ENCASEMENT PIPE AT ALL BORE AND JACKS. THREADED RODS GALVANIZED SHALL BE WELDED TO THE ENCASEMENT PIPE AND BOLTED TO THE FITTING ON BOTH SIDES OF THE GLAND. 23. LIMITS OF DISTURBANCE (LAND DISTURBANCE) FOR CONSTRUCTION OF THIS PROJECT SHALL BE CONTAINED WITHIN TEMPORARY AND PERMANENT EASEMENTS AS WELL AS ROAD RIGHT-OF-WAYS DENOTED ON THE PLANS. 24. EXISTING SURFACE CONTOURS SHOWN WERE TAKEN FROM INFRAWORKS 2018. TOPOGRAPHIC SURVEY FOR HORIZONTAL AND VERTICAL CONTROL WAS PERFORMED BY MCKIM AND CREED. 25.EASEMENT BOUNDARY SURVEYS WERE CONDUCTED BY MCKIM AND CREED IN TO BE COMPLETED. 26. IN ADDITION TO UTILIZING RECORD DRAWING DATA, EXISTING ABOVE -GRADE TOPOGRAPHIC FEATURES WERE REFERENCED USING AERIAL PHOTOGRAPHY OF THE PROJECT AREAS TAKE FROM NC ONE MAP IN JANUARY 2018, OR FROM FIELD INVESTIGATIONS PERFORMED BY MCKIM AND CREED IN NOVEMBER 2019. 27. SOIL BORINGS WERE PERFORMED BY GEOTECHNOLOGIES, INC. 28. WETLAND AND STREAM FEATURES WERE SURVEYED BY MCKIM AND CREED IN JANUARY/FEBRUARY 2020. 29. CONCRETE DRIVEWAY REPAIRS TO BE FROM EXISTING EXPANSION JOINT TO OPEN CUT. 30. ALL NEW WATER MAINS TO BE PIGGED PER JOHNSTON COUNTY STANDARD SPECIFICATIONS UNLESS OTHERWISE NOTED. JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS GENERAL GENERAL NOTES AND LEGEND PROJ. START DATE: 2019.NOV MICE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP SCALE G 2 HORIZONTAL: 1"=40' DRAWING NUM VERTICAL: 1..=4. D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\GENERAL\G.02-003580141-J000385-LEGENDGENNOTES.DWG 03/27/2020 10:14:25 DAVO HAMMOND 8 / V U CONTROL POINT TABLE: 319.617� / POINT # NORTHING EASTING ELEV DESCRIPTION RC----------------------------- 1 667382.16 _ _2191045.753_ _ 219.885_ _RC 7 m 2 - --668098.318 2191503.816 229.982 RC - - - - - - 311.721 - - - - - - - - - - - - - - - - - - - - - - - - - - - - RC 3 674026.035 2189042.25 2_65.247_ _RC Et0 C28 4_ - --674479.998 _2188594.3_26_ _ 2_67.79 _ _RC --- -- _ _ __ _ _ F PRM 5 670214.487 _2184137.571_ _ 2_41.16_2 _ _NCGS LB 26 3 P0N 123 303.368 6 --------- - --670577.474 2183416.724 243.228 RC - _ _ _ - - ��P------------------- RC 7 680844.247 2172232.507 311.721 RC ' C27 8----681528.-- 2171907.502-319_-- RC ------ 100 671202.773 2183266.812 246.326 NS 101 671891.805 2182918.214 251.541 NS 122 I 102_ _ _672624.234 2182686.492 _ 258.924 NS _ _ _ _ _ \ 303.997 I 103- --673030.517 2182045.339 - 259.596- NS - - - - - - NS C26 104 673004.233 2181257.431 250.548 NS ----------------------------- 721 105 673092.177 2180650.425 250.901 NS ----------------------------- 303.225 I 10_6 673436.701 _2179990.789_ _ 2_61.412 NS _ - NS I 10_7- --674096.8_81 2179571.924_ _ 2_62.846_ _NS - - - - - - 120 I 0-108 - --674789.14 _ _2179201.908_ _ 2_70.472_ _NS -_ -_ -_ -_ -_ -_ 298.873 I l // 109 675509.541 2178848.723 276.363 NS RC c C25 / / / // ----------------------------- 110 - --676253.139 2178468.012 _ 284.525 NS _ _ _ 111 / l 111 _ --676869.937 2177941.009 - 306.681- NS - C24 C23 C22 C21 C20 Ns . 681 / 112 - --676900.499 2177180.377 - 299.126- NS - - - - - - 1 I I _11_3 _ _ _676950.8_82_ _2176389.2_4 _ _ 2_88.62 _ _NS _ _ _ _ _ _ / 11_4 _ _ _ 577045.5_5 _ _2175562.6_05_ _ 2_83.483_ _NS _ _ _ _ _ _ 119 \ I i C19 I I / // // // 115 676759.289 2174605.855 287.364 NS 295.828 ----------------------------- NS 110 0khq T 11_6 _ _ _676912.224_ _2175172.809_ _ 2_82.241 _ _NS - - - - - - 716 114 113 112 284.525 qAN RD 117 676758.396 2174607.437 287.379 NS 118 115 283.483 - NS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 293.042 287.364 282.241 NS (NS8.620 299.726 118 676935.915 2174045.079 293.042 NS NS NS Ns NS C18 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - _11_9 _ _ _677028.619_ _2173464.3_86_ _ 2_95.828_ _NS _ / 117 120 677837.873 2173290.885 298.873 RC / 287379 --------------------------- NS 109 276.363 C' / 121 _ _-678680.558 2173132.151_ - 303.225- NS - NS 'QP �122 679407.439 2172853.739 _ 30- - NS _ _ _ _ _ _ NSF O C17 \ / rr123- --680113.758 2172554.006 303.368_ RC 108 267.790 200_ _ _667576.71 _ _2192096.5_89_ _ 230.306 _NS - - - - - - - - - O \ 270.472 ----------------------------- RC / 201 668744.752 2192013.869 243.671 NS NS 202_ _ 669255.6_04_ _2192346.6_65 _ 2_41.987_ _PKS_ -- ,C9 / ----------------------------- C16 - 203 _669546.811 2191729.611 250.337 NS _ _ _ _ \ 3 204 669870.326 2191239.081 250.607 NS 265.247 / 205 670206.233 2190804.294 250.243 NS 262, 846 C15 - RC \ / / _ __ _ 206- --670844.017 2190565.96 - _ 251.069- NS - - - - - NS _ _ 207 671553.904 2190209.132 245.925 NS C8----------------------------- - C14 C13 703 208_ _ _672239.134_ _2189816.739_ _ 2_55.657_ _NS _ _ _ _ _ _ 259.596 210106 NS 7-] 250.719 209 672972.74 2189535.451 247.699 NS 267.412 NS C12 \ / 0 NS 210- --673548.28- 2189338.896 - 250.719- NS A ``� KEY: 05 102 209 �\ C7 RC: REBAR AND CAP 1 250.01 258.924\ 247.699 NS: NAIL SET NS PKS: PK NAIL SET NI - 104. - NS O 208 NCGS LB 26 3: EXISTING NORTH CAROLINA GEODETIC SURVEY 250.548 NS 255.657 NS MONUMENT. �� ❑ II C11 i-C6 n /. \ /P� GS \>O 6 REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 2127/20 C 90�OESIGN- NOT FOR CONSTRUCTION 03/10/20 E 60%DESIGN- NOT FOR CONSTRUCTION OV07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11/16/19 REVISIONS CARC `I` "QoF SS/0*1":9 9 I VV- 246.326 NS- 6 1243.228 PLAN VIEW HORIZ: 1 "=40' v Mga4&CREED v Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com II 5 241.762 NCGS LB 26 JOHNSTON COUNTY DEPARTMENT OF UTILITIES NS \ Y 20 250.60 250.337 NS\ / \ 671 243.671 241.987 PKS 111 1 219.885 RC 200 230.J06 / N N� 800, 0 800, 1600' SCALE: 1"=800' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS GENERAL SHEET INDEX MAP AND SURVEY CONTROL PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP SCALE G 3 HORIZONTAL: r•=40• DRAWING NUMI VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\GENERAL\G.03-003580141-J000385-SHEETINDEXMAP.DWG 03/27/2020 10:14:32 DAVID HAMMOND WILSOJV'S MILS �HRISAN CHURCH TIO I1STALL NEW SEWER I % wF \ \ \ \ \� \ j l�fiE ( $ A I FL WILSON MILL CHRIBTIAN C HURCH 1 L RAL BY OTHE ,S TO THE WET AND SOUTH OF THE N/ 79 FIRE EP MENTRD f ) WI SON MILLS FIRDEPARTME y I CLA ON NC, 27527 \ \ \ \ \ \ - / PROPOSEb LAUNCHING PIT. CONTRACTOR TO CONFIRM ppo000900o PIN: 6960SiB-4315 I I \\\ HERNANDEZ MARIAI6 MIREZ \ \t / L\DCAl10N OF SEWE LATERAL P f R T_0 CONSTRUCTION. Dry:tsssos-,aas \ I I \ y' _\ \ 40POWHATANRD \ - C p�\\ PI IDS 1023 PG 0237 \ F 00896 PG:030 N/F— �\,\ CPN O16 606 18662531W�OBB:04731 PG:0997 LSON MILL0 10000ARTMENT V7IagON MILLS FIRE DEPARTMENT00-0000 DOO_PIN:16 OS-iB-2,97 R N/F —f Q EX. SS �_ \ / DB:0102 P1%241 IN 169605184134 ` 'OOB96 PG:0235 PR OSED TEMPO ARY 6MLSON MILLS CHRIBTIAN CHURCH A R/M-240.55 \ 119 FIRE DEPARTMENT RD I I �� I NV IN(NW)-234.4 B') �- __ \ I SEE TAIL EC-O6 ON I I CO STRUC ON EA EMENT \F N 169605 18-5351 \ II O H00D, TENELLE B i I I /NN�I 'DIiT=229.83'�� �� N/F 1 YOUT T IT LO IION� WILSON MILLS CNIFrIRiST1A CHURCI✓ QB OD896 PG:0233 I �� I I OPEN CUT 4�-1F OF 1'6" SIEE \ O`^/HATAN ROAD \ NIF / SHEET D7 R SILT FENC \ C I \ Cif 9 IRE DEPAR ME RD \ J II Q OASING -THICKNESS A 375" w 47 CF�AF D PIro696C51B751fi00 \ \ Lop IRE ANDRES I STO E FILTER AD IP NET R N VT ON NC69605,8-0260 I » \� ( \ / \ 5' DI-HORI BEND �' » DBolafia cossl I \ CAYTIRNC,27527DEPT 0-0000 I I PROTEC110 WHE E SHOWN 35"x "LAUNCHING T DB:00896PG:03o0 �' 8 4 =' (n A 8 RJ DIP CARRIER PIPE I \ PIN 169 ,eB74s �R STA: +26 I \ DB o1758 '0500 -- SEE DETAI EC-16N ISHEV D8) I \ I � O \ I PROPOSED PERMAN T Imo' I I 45' DI HORIZ BEND \ \ f \ I 8 90' DI i`IORIZ. BENll1 \ ,I S" GATE L \UTILITY EASEMENT (N I I STA: 6+84 -- \ \ ��RS\ \\ t4 H wo�oD q \ \ \ 8" 4 pl HORIZ. B D STA: 3+8$ \ STA: 73 WATER ETER \ ; AW WAATIIU (TYP. \ t1'H CONC. PROPOSED PERMANENT �2 \ \ \ \ ( )---_ u a I yyWWy���FFIIEEEEEE UTILITY EASEMENT I w q� \ — -�--�_ �qSP ; E SHO EE DETAIL R /NG WALL -4 I \ \ \ V(q) -w(R)__ _ _ _ u 1 a I a E 1 ON SHEET (DO NO p�STURB) 18 45' DI HORIZ. BEND I \ \ _ ou s , 0` / - \ --W( - D/P 1B" R P I U \ 5+00 Q 1 11 \ » \ \ \ \ JI I 8 45' DI HORIZ. BEND °� - -w(R) _ _ _ 5J 5 \ P I I \ I 0 DISTURBANCE/ \ \ » (R)-- G I PROPO 8 DIP WAT€ LINE \ ioss STA: 1+47 OF FIR sae, CL ING L ITS (TYR� I I --�--__ I c6 — r R— R - 12"� _ / \ H \ C (WID V�RIES LM I \ EX. MH• 8)55--- E 2+00 R �9O _ - - __ — — — _ f ' . A $ �\ \ \ \ \ + 1- RIM=230. d' -( �5- _-- 8 12" RC / 15" RCP, - = W(R - - - - - /s) - a \ - _8+00 \ \ DEC ORA 1 I - +oo J y -�L--- _P U 7 lNVr S'£- _ _ - Ss- _ - it �w(RJ- - C WALL O INV OU (NW)=21 Z26' " _ T(R - _ r _ _ - - -w( )- - ( - - ou 9 00 \ O Di! -� I " 1- 6" GATE VALVE I -- o(RaTV R( -a - rv(R) - _—� (R� 12 e/P1- - - R _ ou v \ e( W A I LU STA: 1+0�4 1 a a 3�fR)=� - N SS T��R) _ -e R - _ - z - - - OOR -OU - -\ FIR�D _ -- - )_ ou R/ 230.56' )-( -(i _ - - _Z _ 0 \ I II V IN SE 2>7.14' " T _�_ou - - \_ R I I 1 I \ )NV )- !, JACK AND ORE 4� - T RS EL tom_ _ r(R) _ T(R) - o(R)„ � Tv R — 12' INV IN(NE)=217.14 (12) - »-- _ - - \--�_ `SEX. UTILITY EA MENT » CASING (THICKNESS 0.375) LF - __ - -FO R) o - � 8 ATE VALVE 8" RJ DIP CARRIER PIPE I \� Ex SSMN* 1 I 0) �� I o 8"1 DI HO.U! BEND ATE 3+31 I I ? I o A aI fifi —RIM=236.59'--Fo( - - / 1+19 f 1 -- — Z I 1Nv 7N(NW)=a�38' (6) \ _ - _ ( 1 = _ I / I I I INV lN(NE)=229.3 (12) —� / 8 4 DI �H I ND _ v ) N D1 RE CER ✓ 8" 90' JD�HORIZ. BEND INV ouT(sw)=2za.s3 (12) I ' l I STA: 1+06I - _ ST"+35 �/ -� STA) 9 8" DI RI END a " `- A I y f/ I \ 1 \ TEMP. SILT FENCE (TYP. I S +27 / 11 A„ I - N/F 0"x10" RECEIVING 7 ' ---- � y � / I WHERE SHOWN, SEE DE AIL 8* 5' DI HO Z. D � � I I o I I I TOLER, CRYSTAL GAY R EC 8 ON SHEET I S 9 0 4' DI H RIZ. `BEND \ �' 435EBE RTS ALLEY N/F I Z I I CONNECT TO EX. WL I AMHERSTDALE WV, 25607 PROPOSED TEMPORARY �R EZ, JAVIER SANCHEZ \. STA: 1 42 p III w/ 6"x6" CUT -IN DIP TEE PIN: 169605-1"029 CONSTRUCTION EASEMENT pI 3001 BRACEY PL \ OB:04356 PG0423 i �L RALEIGH INC,27610E039 \ N/F \ \ \ \ \ \\ I \ (�.I STA: 1+00 NES, BOX 208H R \ 1 / i PIN: 169605 GOO508 PO BO%20B \ I \ \ \ \ 1 Q ' aQ/Y7Y% I I DB:04828 PG:o050 LS PIIN. 1ILLS NC, 605-i189309 208\ \ I I •\ \ \ NI o I oaag, 0 PG:O05z 1 1 l I pD \ \ /O GO$J CAPPS WILLIAM MILIFEESTATE B PO BOX87 SMIT FIE NC D\E7A5N DODO \ 1\\\ � WILSONS MILLS NC 27593-0087 1 '�— / \ \ I I \P 16 0S2B-1426 N W"' PINDB : 4792 17E933 / / / \ 1 I D 037 PG:0674 \ 0(\ O PLAN VIEW 40' 0 40' 80 HORIZ: 1 "=40' SCALE: 1"=40' (Horiz.) L 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 JL 50 , 48 3 o ' 46 o I EX. RADE (Gl) 44 - o -- o 42 I -� -- - 2 D/P WL DEPTH APPROX)_ 31 i nip Iw 40 / (DEPTH APPROX.) -� 38 WI �I 18"MIN 36 v I v1 3 3 (G/S) 18"MIN » a o Z EX GRADE - - / I 34 w -- - - - - STA: 1 0+42 45' DI HORIZ. BEND DEPTH A PRX .PVC 82 ND 32 8 90' DI HORIZ. . TA: 1+19 END — ' 42_MIN TH APPROX. 13"-45'-Di STA: HOR " STA: 9+75 30 -- ( DEPTH APP ) OT'« / DEPTH AP - / " " ROX. ) I I i I I 1 (... AP ROX.) 1-8"MIN 8" 4_ STA: DI HO 16+84 IZ. BEN -_-- PROPOSED FIR 8" DIP WATER LIN STA. _. 9+90 -,- - I i (EPTH AP ROX.) _ - -- I - '- _ 28 TELE ( DEPThT AP ROX ) — I. 8 9 - DI HO • -- 5 IZ. BEND At 3+35I'. I I I ,- I I I I' i - - APPROX ) r 26 - — - (oE_ rH APPROX) 8" GATE VALVE STA: ,1 +.31 1 I 18"MIN +31 I "- x 0 G4UNC RING P T " STA 6+0 _ _ I C - I 8 SING IN DIp ICKNES 0 375" ' PIPE w/ 47 - L_F_OF 24 22 20 _ _ " 8 GATE STA. VAL - (RO STA: T - LED AS 8+26 r -- I REO D) I rtf I�SL oREncALCARRIER PE (TYP.) - - - " _ L_. CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) " - �W STx6 DI REDUCER A: 1+06 ST - » +04 ST � - _-- " :_1±73 DI HORIZ. 13END 1+47 _-_ DEPTH - O - rHER 1: 1 PPROK) I I T/CAL _ LOPE I 110 RIZ STA: 3+85 CASING, ' (THICKNESS 0.37 DIP CARRIER PIPE " " - I - 18 CONNECT TO EX. WL w/- 6"x6" CUT -IN -DIP TEE STA: 1+00 17 1+00 2+00 3+00 REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 23/2T/20 C 901 DESIGN- NOT FOR CONSTRUCTION 03'13120 B 601 DESIGN- NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/15/19 REVISIONS 4+00 CARp�/N i'% pFESSlO,y•''•:9 '•� ?� S9 ��s�'•. FNGINEE�-•�•1��•�• 0,10 T- 5+00 6+00 7+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' v 1VFM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com JOHNSTON COUNTY DEPARTMENT OF UTILITIES 9+00 10+00 252 250 248 246 244 242 240 238 236 234 232 230 228 226 224 222 220 218 217 11+00 11+53 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL FIRE DEPT RD STA. 1+00 - STA. 11+53 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. KEY: * EXISTING MANHOLE DATA TAKEN FROM RECORD DRAWINGS FOR THE TOWN OF WILSON'S MILLS USDA SEWER SYSTEM IMPROVEMENTS BY THE WOOTEN COMPANY, JULY 2016. PROJ. START DATE: 2019.NOV MCE PROD. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. Ili AJP 4' 13 J 8' SCALE: 1"=4' (Vert.) SCALE C 1 HORIZONTAL: ao DRAWING NUN VERTICAL: D ,.,_4, REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:15:20 DAVID HAMMOND II N� I C85P PERTIES 110 WILS NS MILLS RD SMITHFIE NC, 27577-3244 PIN'169605-18-9963 D01346 PG:0628 I / I R lv I � C NEW FIRE HYDRANT (1 M \ LO �U \ \ F- LLj V) W_ Ld Z J OU- —� (LJJ = V) Q 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 225 REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 03/27120 C 90%DESIGN- NOT FOR CONSTRUCTION O]/10120 B 'OS DESIGN- NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/15119 REVISIONS I I II \ I I I N/F C DISTURB NCE/ I B AKE,PO BOX3 ING LIMITS (T�P.) WILSONS MILLS NC, 1 VARIES) PIN: 169605-29 DB:01412PG: I ASSEMBLY ' STA: 11+93 P OPOSE 8" D P �IE \ STRA WATTLE (TYP. WHER SHO , SEE DETAIL \ / C71;8' ON SHEET D8)II W(R)=f \ TEMP. SILT FENCE WHERE SHOWN, SEE DETAIL \ EC-08 ON SHEET D7) NIF � \ BENSON,ROSEMARVT PO Box 34 mm sous un i s uc 171m1 nn 01. 1 \ `�•V, 1\ , Q y E) SMH' `+I RIM 2 $37' IN I SE)=235.21' (8) \ 11 111 NV 0 W)=235.41' I(8) 1 O 8" 45' DI T. BEN d BA: 16+15 \ OiioON-136B 8" 45' D T. BEND , 1 j184 STA. 16+1 1 11 11 I STONE FlLR PIR INLE I \1 RRROTECTION (TYP. (ERE HOW SSEDETAIL EC-16 )ON S ET DD8) �. \/\ / I /E(R)-.-�/-E(R)- E(R)-- -- (R) / 15+00 / o Pa C 6+0 ,ou yl -- — — — (R)-- P _ --__ R)--..,.,... W(R),—. --_W�R=1d'rl7/1�....— . FI D E I T D \ PIN: 16%05-283616 2SS / E( *121iE( -- 1 pE(R) J/ 13+00 OU U VkR) -TVtR7--�Vkm) -- f — — RTSvI6) TART — vCRr _ �) _ --pp(R--FO(R) -. - �" PP ¢ ' / I a I �/ 0 12" GATE / STA: 2( I 1 1 UNION H�' E HURCH BELTON, WILLIE LARRV \ PO SO 5 NIT PO BOX 2041 WILSONS MILLS NC, 593-0205VINSON, RO DERICK D. MIT LD NC, 21577-2041 PIN: 16%05-29- 23�\ 2",STH AVE PIN' 1 5-2, 591 / F I BE 03463 PG:0 44 PATEPS N NJ, 07504-1601 DB'.04282 PT,':OSBB_ / UNIOf HILLA M E C�URCH \ I \ PIN: 16930" POB X205 DB: PG ILSON MILL NC, 2793-0000 PI :1696 29-124 D 'ouDc.o114 / �RO 2" DIP WATER --- --_ -_ ZJOHNSTON COUNTY CEMETERY LINE (SEE S EET C3) / ,D0000a000 IF \ \ \ '`� / PIN: iB9605-29-3567 / U ION PIOLB X205 CH �—--__-_-- ii'�`i'1 / DB: PG: WILS NS MILLS C, 27593 II \ �_ N: 169805-7779-2224 " \\ / P o 84\\GATEf� LVE N/F —� / / / NOTES: VINSON, RODERICK D. / / / �\ \ 26518THAVE Rl 1. CONTRACTOR SHALL REMOVE PAPINS NNJ,07504 1 1 ���ys�' AND REPLACE EXISTING DB:04982 as4e CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER 8" DI HORa,\ END 1 �� wCR)� / ���' MAIN CONSTRUCTION, NTH a 1 STA�1i6+20 __ �` -=w L \ V / �l�l¢ NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS ' TO MATCH EXISTING tiffs GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE °U �/ ,,-, EXISTING RIGHTS —OF —WAY. �lax'�/ ` HYDRANT SCALE SHOWN 15" CP t�/ FOR CLARITY . - - - 3. CONTRACTOR SHALL EXPOSE = R) .ZT(akS= _(g - ( / UTILITY CROSSINGS THROUGH °M Z r` �� — VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN 41 --7 00 / CONSTRUCTION IS WITHIN 200 2 I GRAV 0/W \ 42— — —� FT OF UTILITY. 4. WATER MAIN SHALL BE \ 1 INSTALLED WITH A MINIMUM OF / \ 1 42 INCHES OF COVER UNDER \� 1 ; I / EUBANKW LOUISED I EITHER THE EDGE OF 'IS) ` 4( - MILLS o � I PAVEMENT OF THE ADJACENT WILSO IN MILLS NC, 27593-0209 `�I 1 PIN:16960629-5323 ROADWAYS OR EXISTING ET) ` US 01035 PG:a655 GRADE, WHICHEVER IS LOWER. 5. EXISTING VALVE SHOWN PER GIS RECORDS. UNABLE TO CONNE T TO EX. WL 1 I I CONFIRM LOCATION DURING w/ 12"x8" C T-IN DIP TEE I I I FIELD INVESTIGATION. I I / r IVkm) I D' EX. VAVLE�j (SEE NOTE 5 THIS S 1� DIP/ WA END BOX ,27 SONS MI MILLS X 294 W1 93-0000 PIN: 169605-28-2972 ,W SANDERS,WI15 MAE T I POBox .27 / WILSO IN MILLS -2 39093-0153 PIN: 1985 PG:-3909 06:01985 PG0443 PLAN VIEW HORIZ: 1 "=40' 16+24 I 1 CONTRACTOR TO CONFIRM EXISTANCE AND 1 OP RABLIUTY OF VALVE IF PRIOR TO CONSTRUCTION WHIT�CORNELL P BOX304 1" I x _ AND NOTIFY OWNER AND R waso"s ILLS NC, 27593-0DOO ENGINEER IMMEDIATELY PI .169605-29-3os6 1 I _ �:! 4 SHOULD CONTRACTOR BE B:0181]PG:03]2 i J �>.„�.�.� UNABLE TO LOCATE. A Ilk - o NEW FIRE HYDRANT �I Q ASSEMBLY �RADE (GAS) EX I �I 0 (DEOTH APP 180MIN COVER ( ) 8" 45' I� Ql VERT. (BEND - - - _ - (EP7H AP ROx) „ „ ---- DEPTH 6'• APPROx.) IP WL 8 GATE VALVE STA: 11+93E STA: 16+ 7 LINE Al� " ���Iw/ END " Q P WATER LINE YL DIP TE RO " DIP WATE CONNECT 12"x8" 'TO EX. CUT-1 PROPOSE .. 12"DIWL L. 18" _ _.. IN 18"MIN TA: 16+24 1 - - - — -- - CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) - B" 46' DI VERT. BEND STA: 16+12 - e" PVc SS - - 8"'. 90' DI HORIZ. B STA: 16 ND 20 - 12+00 13+00 r C..... t%f / EAL •• _ 2 s� •. FNGINEE�. a 14+00 15+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' v NTIQM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 16+00 40' 0 40' 80' KE* EXISTING MANHOLE DATA TAKEN FROM RECORD SCALE: 1"=40' (Horiz.) DRAWINGS FOR THE TOWN OF WILSON'S MILLS USDA SEWER SYSTEM IMPROVEMENTS BY THE 260 WOOTEN COMPANY, JULY 2016. 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 225 17+00 17+25 JOHNSTON COUNTY DEPARTMENT OF UTILITIES JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL FIRE DEPT RD STA. 11+53 - STA. 16+24 PROJ. START DATE: 2019.NOV NICE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 4' 11 J 8' SCALE: 1"=4' (Vert.) C2 SCALE HORIZONTAL: 1"=40' DRAWING NUM VERTICAL: D 1"=4, REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:16:05 DAVID HAMMOND 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 225 PLAN VIEW HORIZ: 1 "=40' I* U F- LIJ LIJ In Ld LIJ In 40' 0 40' 80' SCALE: 1"=40' (Horiz.) i I � I i o EW FIRE` -HYDRA - - - \ --� Tv (DE TH-APPR STA: X)_ +---- 30+01 3 of EPTH APPROX.) (DEPTH APPR X.) Y EX GRACE" (GIS) — TV PTHPROX.) - - rELE (DEP,TH -.-.... APPROX.) -- - - _ - coc C� / �_-EP-TH ROX. — AP-P r) _._.. -. __I— _— — STA:--29+9-Z_—_ Q O ,I ELEC (DEPTH .APPROX.) _ �I Q(ail42 rVIDEPTH b6TH APPROX) APPROX.) _ O N O _.. / /--- (DEPTH PROX.) 'I 12-x6"--DI-1EE-- TA: 30+01 " MIN "x10" RECEIVING ;PIT » \ ; rELE _ _-(DEPTH APPROX.) ---- - -- - (DEPTH APPROX.) — 1 STA': 20+05 i I I { I I_- —--� �" ---- - -- - Iry --- �-- � i -- - ry _- _ - - _ { I '10 Mir UPWARD GRADE TO HYDRANT TO AVOID - -D 8 DIP - - -r 1- --- - } I - - - _ ---- - -- INTERMEDIATE HIGH POINTS (TYP.) PROPOSE WI_ i i I 11 I (EPTH AP OX.) SEE SHEET',C2 { i I ieMIN- 12 45' DI HORIZ. SEND • I � (ROLLE-D - AS REQ'D) _ 8 PVC SS { L_ I - - 12" 2250' DI ORIZ. BEND 1 -- -- - TA: 20+50 I I END STA: 2 +13 I JACK AND BORE 59 LF OF 24 STEEL 1:7 SLOPE CASING (THICKNESS 0.37 ") w/ 59 LF O - - 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 19+00 20+00 21+00 22+00 23+00 24+00 25+00 26+00 27+00 28+00 29+00 30+00 30+42 PROFILE VIEW HORIZ: 1"=40' VERT. 1 "=4' REV.NO. DESCRIPTION DATE D ISSUEDFOR PERMITTING -NOT FOR CONSTRUCTION 23/27/20 C 90%DESIGN- NOT FOR CONSTRUCTION 03/13/20 B 60%DESIGN- NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/15/19 REVISIONS 10 v NI�I�VI�CIZEED v Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License* F-1222 www.mckimcreed.com JOHNSTON COUNTY DEPARTMENT OF UTILITIES JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL POWHATAN RD STA. 20+00 - STA. 30+42 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. KEY: * EXISTING MANHOLE DATA TAKEN FROM RECORD DRAWINGS FOR THE TOWN OF WILSON'S MILLS USDA SEWER SYSTEM IMPROVEMENTS BY THE WOOTEN COMPANY, JULY 2016. PROJ.START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP a a Ell SCALE: 1"=4' (Vert.) SCALE C3 HORIZONTAL: =40' pRAVJING NUN VERTICAL: D REVISION 'STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80—DRAWINGS\CIVIL\C.01-003580141—J000385—SHEET&BASE.DWG 03/27/2020 10:16:50 DAVID HAMMOND 1 1 � i 1 i NIF DJ'S PROPERTIES INC 500E NC 210 HWY N/F � SMITHFIELD NC, 27577-2098 DJ'S PROPERTIES IIJC PIN. 169605-19-2504 1001 NC".. 0 210 H 08:03B19 PG:0735 SMITHFIELD NC, 27577-209(3 PIN: 169605-19Q48a /DB`63819 PG:0729 ,V 1 1 I y Gu - N 2uROAOi— +ON — — — — O M to R) v(R1- _ _ i R T pF y�LS pp U _ ivCir- ) _ R — ( L� J _ -i(R Z STRAW WATTLE (TY _ — —� /SHOWN �U1 _ lR q I I rz�: / EC- 18 ON SH T I J I I I / MP. STRA� W� W, , NET' UN R b (TYP. RE SH WN / NIF / IFFORD III E E SETAIL EC/-19 S EE UZZLE GEORGF.DC/ p - ° P 0X 12 WILS ILLS NC, 27593-0000 PIN 169700-10-7117 W 1 �-- -�-- —� DB:01142 PGi6` 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 225 �� I FZ / � + I 1 N/F zt MARTINEZ//`UCIA N1I DJ'S PROPERTS INC I 231 HARRI&ON RD _ DJ'S PRO ERTIES INC 100E NC 210 WY I CLAYTON N 27527EOOt i ' / 100t C 210 HVJY SMITHFIELD NC 577-2098 '' PIN: 169$QOS-19-0fiO3 „, SMITHF D NC 27577-2098 11 I PIN DB93819P1'07359 D6:05�"44 PG,0650 t-. / PI6i03819"BS05P-0G90735 P OTE CTI EE DETI / 11 _OMPOST �OCK ( / WHERE S AN, SEJETAIL I I I EC-15 AFI SHEET Y 1 1 FILTER IF P. WHERE -16 ON th / LIMITS OF DIS E CLEARINGel" ITS / ( DTH 1 INLET-N DJ1S00. :P INC NCH 0 SMILNC \ V\ THFED 74000 PIN16 8DBO AV \T \ I\ / STONE FILTER PIKE INLET \ \ PROTECTION (TYP. yV1{E SHOWN, l SEE DETAIL EC-1�N HEET DS)I 1R1 S)I o INV.-:Z44.678' �a)1 r + \ WALL J _ �NIRi A a 10_45,DI HORIZ. BE X N/F ONSSCHMIL BOX182 ,21DM WIL'6ONS MILLS _0 _5093-0182 / \ \PIN'. 02248 G:02919 \� oB:Dz24e PG:Dzs1 Cj NIF / \ L. PJS REAL ESTATE, LLC PO BOX 133 � CLAY Pit 702752E-0733 \rJ PIN: 169700-00-0265 \ DB04903 PG0247 \�S ygTq STA 38+31 \ T / SILT E OUTLET E \ r,: PRO E1�12"-Pt� A LIN A WHERE SH SEE DE IL EC-12 ON S ElT D7 \ \ \ Xh 0 12 455-DI HORIZ. BEND _STAA: 35+37�O / 12" 4 D HORIZ. BENDG 35+25 )LC 11 \ F / \ /TEMP. SILT,,1 ENCE \ \ TVYER INVES QEB TS HOLDINGS, WHERE SHOWN, SE DETAIL �� \ CLAYTONNC, 7526-D190 /I ��_l EC-08 ON SHE D7) / / \� v PIN:16970 07198 / DB:05343 P :0036 LG C DETAIL J ///l F / / R / PROPED PRMANEN UZZLE, ( GR'GE CLIFFO/IFD III I WF UTY/EAS�MENT A / WILSS INNf 6700-10 775�3-0000 110 I SMITHFIIELDMMM�AAAC, 2 577 3229 / k7 • / \Il-\ f DR 01142 PG'06 2 (\ PIN: 169 00-00-9231 / DB 043 6 PG'0317 PLAN VIEW HORIZ: 1 "=40' 40' 0 40' 80 SCALE: 1"=40' (Horiz.) TV zI N 2 _ DEP APPROX. 3 O " WATER LINE I e I — TV D-- EPTH A 7V X. GRAD (GIs) i PROX.) � COVER (TYP) TV I TV TV --- -- J, ._ L ---- ' - -- ---- _. 6"-P_V/jC_WL-- (DEPT APPRO -- ) (DEPTH APPROX.) - - --- _- -- -- - 4" RCP 10 18"MIN 2 "MIN -- - 1 45' DI HORIZ. END CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) 14 STA:- 3-5-- 25 I --- --- - - TA: 35 37 j- I 31+00 32+00 33+00 34+00 REV.NO. DESCRIPTION DATE 0 j ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 03/27/20 C 90%DESIGN-NOTFORCONSTRUCTION 03/13/20 B "./. ESIGN- NOT FOR CONSTRUCTION 02JO7120 A 30%DESIGN - NOT FOR CONSTRUCTION 11116/19 REVISIONS r `�.\o�tN I C..... ' SEAL - 049224/� /r��7JJ 0. 35+00 36+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' v v NIcMM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 wvvw.mckimcreed.com 37+00 38+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 39+00 Erelffeire, 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 225 40+55 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL POWHATAN RD STA. 30+42 - STA. 40+55 N\ NOTE 1. COS: NTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROD. MGR. AJP 11 11 8' SCALE: 1 "=4' (Vert.) SCALE HORIZONTAL: C4 1"=40' DRAWING NUM VERTICAL: D ,..=4. REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.O1-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:17:34 DAVID HAMMOND N8 PJB REAL E.STATE: LLC PO BOX 133 I t CLAYTON NC, 752"5 27528- 16 \ PIT 1 DB:04903 PG:0247 \253 I \ I c \ I � I / a C / N/F BENNE DONALD S. 383 PO N RO N/C CLAVTON NC 2] -7AB8 d' 1 /.. / x'•/ I I P'B PIN: 161700-00-0 I A WP e STARS POWI7ATAN D RL DB'02956 PG.01 WF / I I J to 1 CLAYTON NC, 2752 0000 KAD INC JASINSKI, TERRY '� JJ / - 1 / PIN: 1697000049 5 1025 RIDGE DRIVE �. . I �-.1 /�/ 493 PONMATAN AD .9YTON NC, 27 7-0000 DB:03827 PG:O85 F� CLAYTON', 2750000 „g;. (, 1 \ \ PIN: IN 163700-0Ot4564 - - ^ jr'168]0 3729 ^� / DI TEE I DB 02766 PG 0307 / I Q fq I I DB 01405 G -.0507 / , 41+73 I 01 PLUG THRUST BLOCK. I -6" DI CAP I 3 I STA: 41+79 ° o OL y 0 ou � - A _ POWHATAN C 3 _ _ (SR 190 Q7 =I B,l 17F•� _— ou---0u---P=°u-------ou 3 ° NDON W PLACE 3 OF DISTURBANC - a C AIRING LIMITS (TYP) x ou�/ 946 LF OF \ E — EX. 6 PVC _WL' (WIDTH VARIES) / I _ _ e SEE NOTE 5 THIS SHEET (RT�v(LL- T� ="i)_= = T(� =WLR� = (Ri =SR = T R =1R1 =�C�= �1 R)-- =w} --R =wf� --ryp(R)-- FO x.— — — — _� — R --- FOUTV 12STA:' 3 95 —_T(R)— — —T(R)—-—TR)-- —T(R)_ --T(R .. - _ TR) T(RY 46'i'00 T(R)—.—_� TEFL 4it00��"� 7(R---(R)_ T�,t}�C_ A>-/W(R,y�-H Htx+ -k� (R�'-{- - fw R —SS(R) — —SS(R)-- --SS(R)------ --ss - h. L co k4 6" GATE V�VE STA: 41+7 _k o� COMPOST SOCK (TI(P. I EX. zSS4�H* / /oJ I 12"x6" DI TEE poi / h WHERE S OWN, SE DETAIL RlM= INV l (NW)-23 .04' (8") /a STA: 41 73 / 12" GATE VALVE EC-15 0 SHEET 7) INV I (W)=23 .04' (8') / 12 22.5 - DI HOf}IZ. BEND / STA: 43+91 l NV/0UT(SE)�37.81'78 STA: 41 58 ' //'' / PROPO 0 l Ij l 1 PROPOS D PERM WENT I NEW FIRE HYDRANT 77 / / / E/ ULITYlEASEMET N/F I CLEMENT RONNIE GR Y JR, 651 PORI 1. CLAYTON NC 27527-60 PIN 169700-01-1039 OR 01508 PG:0668 \ \ I I 2 I -cu _.. _ _T(R)— -- —T(R) --- _--:_- WIRI- In v(R c o rv(K7 - F°(,N(R)-Tv(R)�(�--Tv(R)EO�R -ry N L0 CO U _ _T(R)-_ —T(ft)__ _�-T(R) T(Rr — _R)— — LLJ LLJ Z (n s --- J LLl LLI F U -EX. SSMH*F- R/M=247.13' --2-4-5- \ RIM=245.92' I Q INV IN(NW) =,299.14-(�e) INV OUT(SE)=\240.00' (8') `, f. m INV OUJ(-SE)=238.94' (8") PitOPOSED P€RMAT "PVC WATER LIN UTILITY EASEMET --- /1 / U1ILITY ASEME T ASSEMBLY \ 12" 45 DI HORIZ. BEND STA: 43+95 / TEMP. SI FENCE (TYP. I \oQ /A WHERE�OWN, SEE DETAIL \ / S ( STA: 41�+42 ' / / y / I EX. SSMH* ` \ / I EC-0 ON SHEET D7 I INV IN(S)' 23 27' (8) ' \ ,. t._ I f I / / / / /SILT CE OUTLET fYP. _.j -� PARKER - _ / INV IN(NW)-2 6.09' (8') I FE1 / WHERE/ SHOWN, S DETAIL / - - I NIT e ( or y 1 INV OUT(E)-2 6.25' (8) / /;-�_ Po BOX 7272 OPEN CUT I44 LF OF 24" STEE I `55 N/F / EC-1 �2 ON SHEE D7) GARNER I1669-� l2a5 oD / \ TIJI PARKER, GRACE e I I r �� DB:02920 PG:0918 I l CASING ( ICKNESS 0.375) w/ 44 LF OF Po Box 12]2 / / I NIP _ GARNER NC, 2752970000 PARKER, GRACE B \ \ Q I I I 24 RJ DI CARRIER PIPE / I / \ PIN: 077 PC0 215 / ER Box, DB'00772 PG:0215 / � GARNER NC, 29-0000 / PIN: 1697 0-11-2024 P1 Q PROPOSED ERMANENT R \ / / / / / / oe:o0 2PG:021� UTILITY EA EMENT NIF _ \ 1 Jewel / I PARKER, GRPO OX 727� A AC B / GARNER NC, 2752 -0000 \ I / PIN: 1ss7oo-0o-7 0 II / / II I DB:00772 PG:02 1 5 PLAN VIEW 40' 0 40' 80' HORIZ: 1"=40' SCALE: 1"=40' (Horiz.) 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 U U NEW FIRE HIDRANT --- -� Lo c-)I ASSEMBLY Y _ c3 2- GAIE -S VALVE 43+91 '\� E . GRADE CIS) i� TV DEP PPROX. LE - JI I (DE?T* APPR X.)\ - 18"MINT--} - - - - 12 x6 STA:-143+-95 DI TE 42" MIN 12 STA- 6 DI TEE 41+73' UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) COVER ( ,) -- ELEG APPROX. --'-- - --- (DEPr I I . 12w 22.50' STA: 41+5 DI HORN. - BEND PROPOS D 12" PVC WATER LINE _ 12" 45' DI HORIZ. STA:'; 41+42 BEND - " - - - 1: 1 SLOP AL (Typ•) CA (THICKNESS CARRIER 0.375") PIPE w/ 44 LF F RSINO 12"CASINO CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) PVC s (DEPTH 41+00 42+00 43+00 44+00 45+00 46+00 PROFILE VIEW HORIZ: 1"=40' VERT: 1"=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 03/27/20 C 90Y. DESIGN -NOT FOR CONSTRUCTION 03113/20 B ".I.DESIGN-NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/1S/19 REVISIONS eA4*jWFK1N4&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 47+00 48+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 5RITIE0 50+00 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 51+00 51+25 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL POWHATAN RD STA. 40+55 - STA. 51+25 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. 5. PRIOR TO ABANDONING EXISTING WATER MAIN, CONTRACTOR SHALL CONFIRM IF SERVICES ARE CONNECTED TO THIS LINE. ALL SERVICES ON THIS LINE SHOULD RECONNECT TO PROPOSED 12" MAIN. PROVIDE NEW CORP STOP AND NEW SERVICE PIPING BETWEEN PROPOSED 12" WATER MAIN AND EXISTING WATER METER. ROUTE AND CONNECT NEW SERVICE TO EXISTING WATER METER. MATCH EXISTING SERVICE DIAMETERS AND KEEP LOCATION OF NEW SERVICE AS CLOSE TO EXISTING AS POSSIBLE. LOCATE AND REMOVE EXISTING MAINLINE VALVE BOXES AND RESEED PER CONTRACT DOCUMENTS. RETURN EXISTING VALVE BOXES AND COVERS TO I/ JOHNSTON COUNTY. KEY: ■ EXISTING MANHOLE DATA TAKEN FROM AS -BUILT DRAWINGS FOR THE TOWN OF WILSON'S MILLS USDA SEWER SYSTEM IMPROVEMENTS BY THE WOOTEN COMPANY, JULY 2016. PROD. START DATE: 2019.NOV NICE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP rel III 8' SCALE: 1"=4' (Vert.) Cj 5 SCALE HORIZONTAL: 1"=40' DRAWING NUM VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80—DRAWINGS\CIVIL\C.01-003580141—J000385—SHEET&BASE.DWG 03/27/2020 10:18:16 DAVID HAMMOND 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 \ / I / N/F \, / ... I I I I I NIF I p N/F WILLIAMS, KIMBERLV EER I If/ /,{' I II v / N/F 1( p BETANCOU ERICKA GA8RIELA SAUCEDO1 \ RICHARDSNJENN ERM R �" ST JOHN DISCIPLE CHURCH / 20M SWIFTr RD \ IF JI I ^ I I WHITI,EN CHARLES EOWARD 'L 104 MALLARD CT k� 1102 FULLER ST %3MITHFIELD NC, 27517-7604 I POWHAT PLACE TRUST m I I 0 // I I 7 POWHATAN RD I S . J NC, 27576-T 571 POWH/ I PIN: 168700-91-8538 655P WHATANRD A �2 SMITHFIELD NC, 27577-0000 \ / I Q I CLA qN yC, 2]52]6009 �IN' 168700-92E0W 1111N NC, 2752] 0 / PIN: 169700-0ib812 DB 04267 PG:0270 J pp CLAVT N NC, 27527-6009 I >> 1 Q I IN: i6�/00-91 b960 .. \ I �g,O4B30 PG.0535 PIN: 168700-91-8380 'L PIN: 168700-91-7745 \ I- / 0:14070 PG:0235 \ DB'03240 PG'0152 \ / D8:029]9 PG:0376 - ,. I / \ \ / D�:05226 PG 0122 I I i N I I \ L�� I 1 I PR POSED TEMPORARY \ AB NDON IN PLACE I ✓ I I J =' I COI�STRUC ON EASEMENT 78 LF OF " EX 6" PVC \ ti 10�xT�R CEIVING PIT \ \ (SFjE NOTES THIS SHEET) \I A I W z I I \ / _ V y �I \ 12 90' II HORIZ. BEND „�— ou\\�� I lNV=242.75' �CEMETARY SILT FENCE OUTLET ( MITt') DF ISTURBANCE/ / / / CONC. LINED i i IY I I STA: 60+ 0 Q ou u WHERE SHOWN, SEE AIL DITCH 11 4 I 12 GATE LVE R CLEARING LIMITS \ \ ouEC-12 ON SHEET D7 (WIDTH VARIES � I / 6" DI PLUG /h I 1 STA: 60+ 7 N z u7 - C) e" w `�- W W N _Z J Lj U U) I I -- _ STA: 58+92 I h STRAW W TTL (TYP. T(R) T(R) _ _ o----_ '—moo/ / 6 CAN VAULT al \ �J 1 I I HEADWALL oU WHERE S 0 SEE DETAIL Y - = ry a 0(R� _ -. r(a) _) __ _ - - - - — _ _ _ �ou ou % '- I EC-18 Ot� SH F� D8) 1-= _ T(R}_- - _ oULO —_ _-_ -T(R) - _ _T(R) T/o1// OU © _ OU \\ C I \ I I c0 -�\T —--T(R)__ --- _--- -- -- (W3-__-- r_- b J OU I A O �\ I _ - P17WWATAAI mm -=m-_--_tu',mro1 -- T(� -- -T (?J)3- NV'=243.08' PERMANEf T UTILITY EASEME OTT NIF \ \ A PARKER, GRACE \\ PO BOX 1272 GANERyq, 27529-0000 _ jZkk p PIN: 169700 Z6555 L \ OR 02,21 PG 091 If 1901) •. - n 4� o \ C) 75 CM pp SUPPORT POWER POLE AS NEEDED FOR EX. SSMH* \ EX SSMH*� CONSfRLICTION RIM=248.75' y�,,` I RIM=249.86' `-PVC WATER LINE \ \ \ \ INV IN(NW)=239.63' (a T \INV 0 N(S )=238.83' (8 ) "EMP. STRAW W/ NET LINE INv (TYP. WHERE SHOWNouT(�=238.83' (8) M s \\ \ \ , I TEMP. COMBO SILT/TREE SEE DETAIL C-19 ON SHEET DS) I I \20TECTIQN FENLY� (TYP. WHERE SHOWN SEE DETAIL 3 J W LIj —FM R < — 1 \�I 7 -T I \ JACK AND -BORE 47 LF 'F 24" STEEL 12" GA VALVE \ - CASING (THICK SS 0.37�5"), w/ 47 LF OF ST 59+46 -_ _csF �� 12" RJ DIP CARR PIPF� II RI HORIIZ. BrND / -- \ \ 'STA 9+53 I \EC- ON SHEET x10" LAUNC tNG PI MP. SILT FENCE (TYP. N/F \� WHERE �SHQWN, SEE DETAIL \ -'r `-- \ \ �� \ \m ST JOHN DISCIPLE CHURCH \ \ aN. R ROPOSED TEM ORARY i N/F -- - 1a2 FULLER ST \ EC-0� SKEET I \ CUP N E529- DISON M CTAF SMITHFIELD 04H_6812 0 I CO STRUCTION EA EMENT - \ \ 3 oOGAN 168700R 2281951 PIN: 169]00-01 b812 PIN: 1887W- 2-6195 OB:12979 PG:0376\ \ \ \ Nff / \ 0B01787 PG. 254 POG6,DEVELOPMENT, LLC N/F f - 12 pIL�IAL DR \ \ \ �— —/ —COLLINS ELSIE M \ /) \ CLAYTON NC, 2751FBT38-- J N/F i 792 SHAFFER ST 1 PIN: 169]00-01-0957 IF I CORONA CA, 92879-0BW \ \ POGO DEVEL MENT, LLC WI DER, OELPHINE D DB 04732 PG:0693 I PO BOX 103 PIN: 12891 P 2-4318 \ I C 12 ONONC, 2752 R -- OB:02891 PG'.024ft NS MILLS NC, 27593-0 PIN.yy47S2?G2-0164 PIN: 169700-02J2 \04��c oss— OB:D1 04m / I I I PLAN VIEW HORIZ: 1 "=40' 40' 0 40' 80, SCALE: 1"=40' (Horiz.) _ TV _. (DEPTH APPROX.) - - `----- -- - --- - -. _ ... (DEPITt�_APP-ROX,)_ rFO TV (DEPTH APPROX.) '. ;ELEC ------ I (DEPTH APPROX.) DEPTH APPROX. Q, ELEC (DEPTH APPROX.) 7 LE .3 I ( DEPTH APPRGX ---� -iI-- -_ � i I' I I II _I i - ELEC —(DEPTH 4PPROX.) ---- --- I —_ --4"PVC ( DEPTH (V•) APPRP I I I I I I(DEPTH APPROX) — I I PITS I I I i ' I i 35+• x10" - - LAUNCHING ELEC--i.__... (DEPTH APPROX. — � I _ EX. GRADE (GlS) x LIVINU I'll - - dl�2 MIN - — - 12 GATE STA- I'.. VALVE - tpROPQrFQ12" 12' 90' DI HORIZ BEND-:-_OTA 59153 I - - "STA:-_6.0+1-- Ian- Dl HORIZ BEN - PVC WATE LINEI THEORETICAL : 1 I I STA: 60+10 RE 47 LF OF 24" STEEL - CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) _ - 8" PVC �DEPTH_� CASING PRox.) 72` R (THICKNESS rDiP OANESS 0. PPE 75") w/ 47 LF F CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) I 52+00 53+00 54+00 55+00 56+00 57+00 PROFILE VIEW HORIZ: 1"=40' VERT. 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 0L27/20 C 90%DESIGN- NOT FOR CONSTRUCTION 03/13/20 B 60%DESIGN- NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/15/19 REVISIONS v N 4CMI&CREED v Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 58+00 59+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 60+00 61+00 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 61+65 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL POWHATAN RD STA. 51 +25 - STA. 61 +65 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. 5. PRIOR TO ABANDONING EXISTING WATER MAIN, CONTRACTOR SHALL CONFIRM IF SERVICES ARE CONNECTED TO THIS LINE. ALL SERVICES ON THIS LINE SHOULD RECONNECT TO PROPOSED 12" MAIN. PROVIDE NEW CORP STOP AND NEW SERVICE PIPING BETWEEN PROPOSED 12" WATER MAIN AND EXISTING WATER METER. ROUTE AND CONNECT NEW SERVICE TO EXISTING WATER METER. MATCH EXISTING SERVICE DIAMETERS AND KEEP LOCATION OF NEW SERVICE AS CLOSE TO EXISTING AS POSSIBLE. LOCATE AND REMOVE EXISTING MAINLINE VALVE BOXES AND RESEED PER CONTRACT DOCUMENTS. RETURN EXISTING VALVE BOXES AND COVERS TO JOHNSTON COUNTY. KEY: * EXISTING MANHOLE DATA TAKEN FROM AS -BUILT DRAWINGS FOR THE TOWN OF WILSON'S MILLS USDA SEWER SYSTEM IMPROVEMENTS BY THE WOOTEN COMPANY, JULY 2016. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP !1 99 J 8' SCALE: 1"=4' (Vert.) C6 SCALE HORIZONTAL: 1 "=40- DRAWING NUM VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:19:01 DAVID HAMMOND -� iN OSIE� I \ N/F �+ \ N/F- \ \ / 745 POWHATAN RD I SMITH EDDIE A \ 1 \ G&C PRO PERTI S AND INVESTMENTS LLC F GSC PROPERTIES AN INVESTMENT\LC \ p CLAVTON N6 2]527-0000 765 PO AN RD /' / I 378 LSON JONES RD PIN: 168700-92-0382 / / \CLAY ON�J$27-0000 CLAq6N NC,27520E846 I ' BWILSON ONES RO \ \ NIF D8:03874 PG0179 I 1 DIN' 168 ?,.;¢q06 v IFFFRRRIII: 168700-92-0698 CLAYTON NCL27520-6848 \ IGHT. ALICE FIVE BYRD i ' \ \ PIN'. 142r P92-0778 N/D I �� pp DB:00912 PG.027 B:04250 PG'.0430 IG/, \ \ �\ 725 POWHATAN RD / •L \ \ \ \ I DB:042 PG:0430 J ]�.L CI" N NC, 27527-0000 / \',\ G&C PR0378 WILSO DJONES DENTS LLC a+` PIN 00-92E21, CLAYTON NC, 2752MMI TEMP. SILT FENCE (TYP. PIN tse'D z-0saz DB 0 SS '0065 I NIF r� f 4' CHAIN G&C PROPERTIES AND INVESTMENTS LLC \ \ LINK / / I WI ERE SHOV�N, rSEE DETAI j r EC -OS ON SHEET D7 ;f;. - _ 378 "SON JONES RD I"— P18.16870N0-93-0009 LINK \ F. l / - ' I I "k " CLAVTON NC, 27520E848 N258 PG:0005 \ i �\ l \ \ P / t4' cHAIK \ \ LIMITS F DISTURBANCE/ �� \ � ��� V Gac1 CHAIN / / CI FAR] G LIMITS TYP. LINK /A \ / \ 12 VC WA R LIN (WIDTH I( ) TEMP. W W 1 NET LINER RE SHOWN,- \NEWEIFY[fRANT TELECOM t A -� o // ¢ �� \ \ / ( ) \ SEE DETAIL EC-19 ON SHEET D8 \ I CA TV VAULT - ASSEMBLY I \ ¢ /�+0086t00 �/ \\ \ I I ) \ STA: 63+65 a , --- _i I / oY _; 67+00 e Q \ ¢ - - 0(R � / 681 �0 -- 6400 OJ63b00—oU R15CP 700 71+00 oL62+00 ry \ O N OD W c=n RD , T�(R) l _�(R>- - sR>— -- - _ _ TV R iR) / �— AN RD __ --- -- (n 1v(R _ -- - - _ _-Tv( --_� --�vER)'- lrvAR) R==== Z901 (n 1u( _ _ �o - - \ J - _-�(R3�L r i �( Tv - - _ - - `\ - J LIJ / VR TR — — / ULLJ - :. -\ STONE FILTERE INLET / -- - - f- - 12 DI TEE PROTECT19P1" (TYP. ERE SHOWN ou— ' i_ �� _/ _ o -- v(R)-�` -- - rv(R). -- --- -. _ (R Q � SFN+ A STA: 63+65 / SEE -DETAIL EC- VON SHEET D8) / /you c_ _ _ - - Q A r / �._� 12" GiT3+60 E VALVE \ \ �� \ % j EX. SSMH ou�� Cam__ - STA: N \ R2 2R�\ o / ou v our(s)=242.42' (8) ou EX. SSM/ h H' ry\ RIM=252.40' / STRA WATTLE \ \ \ / \ \ \ AOU l SN)=241.57' (8')/ \ \WHERE�SHOW�I�SEE D TAIL \ i ` � ou____� EX. SSMHS4' I v ou7l'Sf)=247.3T (8') EC- ON SH D8) -� COMPOSTS (TAP. WHERE SHOWN, SEED AIL \ s R/M�.40' \ \ \ �� / A\ lNV lN(NW)=240.46' (8') \ � \ / � � / \ EXISTING LAND - \ EC-15 ON SHEET "'� \ \ PP\ WV OUT(SE)=240.26' (8) \ CLEARED FOUR ALL �- CREEK S(78D1VISION WE / \ \ \ �h \ / ---� (BY OTHERS) JONES, JO T R \ 1 POWHATAN RD \ \ / IL \ j / \ CLA N NC, 27527-DDDo DBO 6700-92�234 I F f✓-`^..y, /,f+ - NIF \ �15OPG.O024 y-. �+ JONES J0 EPHRUEBEN 105 PINT „- 734 PO ATAN ft0A0 � � � ' / � \ � � � / HD]08 MAIN BTEK .+ CLA 1 0. 27527-0000 / / \ \ PIN:ro 8700-92-7387 \ \ EVANSTON IL 60202-1702 PIN: 169700 GN733g DB: PG: DBrE13242B PLAN VIEW HORIZ: 1"=40' 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 40' 0 40' 80 SCALE: 1"=40' (Horiz.) I o a 3 QI el o NEW FIRE HYDRANT - - ASSEMBLY-- STA: 63+65 c� � I U t � I 3 STA: 63+60 - - - - 42 MIN (TYP.) c�D _ - --- - -COVE 12"x6" I DI TEE- j 63+65 - ---- - - D s EPTH APP Ex. GRAD (c/s) - -- -- -- STA:A OX. (DEPTH APPROX.) — — N 18"MIN PVC AFATER L - - I CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) 62+00 63+00 64+00 65+00 66+00 67+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING - NOT FOR CONSTRUCTION 00127/20 C 90% DESIGN -NOT FOR CONSTRUCTION 00713/20 B 60% DESIGN -NOT FOR CONSTRUCTION OV07120 A 30% DESIGN -NOT FOR CONSTRUCTION 11/15/19 REVISIONS 00 i �\ \vv`kjj ZF\ I-�ARp �•�� �: Q�ypF ESS10N9 •.9 ': S ' 049224 :c O I I nHV�G`��` yo 4f a�.2o + e4w* Nf1QM &CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 68+00 69+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 70+00 71 +00 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 72+00 5 CIVIL POWHATAN RD STA. 61+65 - STA. 72+05 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. KEY: * EXISTING MANHOLE DATA TAKEN FROM RECORD DRAWINGS FOR THE TOWN OF WILSON'S MILLS USDA SEWER SYSTEM IMPROVEMENTS BY THE WOOTEN COMPANY, JULY 2016. PROJ. START DATE: 2019.NOV MICE PROD. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 0 m IN SCALE: 1"=4' (Vert.) SCALE C7 HORIZONTAL: 1"=40' DRAWING NUMBER VERTICAL: D 1 „=4, REVISION c TATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:19:46 DAVID HAMMOND NIF \ R / /DS / \ / /NE MAC n s+r \\ OPERTIES AND INVESTMENTS LLC NES RDDp� NI _ _ / HOLEN+ p CLAYTON NC, 9520-6848 'L �/ / _ �— EO 021RP O,WNOATAN RDJR L /EDWARDS J/OHNNVT R/ / / / / / MITHf1DSNC 2TON R 77-0000 PIN'. 168700-934009 \ _ - `-�� CL(sY'FiT NC, 27527-0000 -- -- / -- 1021 POWHAT RJD / / /P1 PIN' 168700-63 jF'+py7W IDS 04258 PG:0065 , / ��� PIN: 168700-93-1522 / _ CLAYTON NC 527 27-0000 D�014B0 PG>11282 DB 02757 PG 0524 L _ -'Z�8 PIN: 168{'.�10 9&166 f/ DB:01757 PG0524 I / \ / / C) \ \ / TEMP. STRAW W)' NET UN�R 1 x / / / / / / \ / (TYP WHERE SHOWN, PROPOSED 12" P R E �" IN^ /� SEE DETAIL EC-19 ON>SHEET D8) �- / \ / r ` + U <) 7 '\ -24-7 NEW FIRE HYDRANT , / / TF� SILT F� (TYP. /12" 45" DI H RIZ. BE�YVD / I l (rya 1 0 / \ I 00 U Q t / ASSEMBLY f �- �AfiERE SHO�Id SEE DETA: 804 3 STA;- 76+21 / / EC 8 ON SH T D / a V a ~ LV� jam, o p B ) 2 45' I HORIZ(BE D I 1- u3 _ too � � � � 12" GATE VALVE / 2 2fl A 77+21 / � � STA: 180+ 1 Ls 8 +00 _ _ N u1 4l 1 J v /a -45' DI HORIZ. ND \ __w(a) _ I 5- 2 / / STA: 76+16 Q 00 lit U1 I\ L - — __ 45' HORIZ. BEN /STA: 7+3� = 75+00 76+00 77+00 9+00 3 fiw(_w -- Q -- U I --- ---�� / ��O o B,.PVGW(R)--_-----yy(R)-----W(R)— // r lln.ln L R —_ \ _ rV�� ,F - _ �POWHATAN RD --- 12„x6„ DI PO�iVHATAN R / - _��Y) L --. _ rv( ----T(— _ FO --- ---__7(RL� _ _ R Z( —_ --T R)'-- -TV(R) .,, OU °U ! --FO(R)-----FO R) F0(R)—�T= _—-r�rpoy----TV(R)-- TV(R)-----7 (R)— \ TV(R)---TV(R)_— TV(R)--- TV(R)—TV(R)— — —TV —--TV(R) F — (rt/—� V (� O 2_ — — — — — — — — — 1 STONE FINER PIPE INLE — — — — — — — oU ou--ems ---- \ ou PROTECTION TYP. WHERE SHOWN, / ou�OU�— \\\ SEE DETAIL EC-16 ON SHEET D8 Ou / SILT NICE OUTLET (TYP ou�°U WERE S SEE DETAIL 0u I \ EC-1 ON SHEET D7) HOP MILLC EK I / ro I 1 BOX708MAI�� \ TOWN PO BOX qqg MILLS EVADB 052 2 PG 07 1702 \I \ PIN: 168700-93-5860 / PIN' 169700-03-333 \ WILSONS MILLS NC, 27593-0000 08:05242 PG:O]48 �• 1 \ DB:04135 PG:0280 PLAN VIEW HORIZ: 1 "=40' 270 268 266 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 235 1 � I I 1 N/F `\ 1 CRAB REE,JAMES MARK B POWHATAN RD CLA ON INC, 27527-0000 \ PIN: 168700-93-1919 ^6 03239 PG:0936 I ; N k 40' 0 40' 80' SCALE: 1 "=40' (Horiz.) 3 O e i (DEPTH APPROX) i v / i (DEPTH APPROX.) GRADE GIS 18"MIN \ NEW FIRE HI'YDRANT LEX. - o ,� e ASSEMBLY TA 76+21--- -- 8" Dvc K IT _ --- - - . - 12"--45'-DI-HORIZ.-BEN A9MIN " 1 STA: 80+02 _ =, �LEC EPTH-AgPROX.) ELEc I - -.----_._. COVER (TYP)---- _L.—. _. ---- -180-MIN--i--- - . ] HORIZ.. BEND STA: 80+13 ------ __...... ---- DEPTH APPROXa — I — - - -- ---- STA: - _ 76+16 _ 12" 1�45' DI ORIZ. BEND TA: 77 21 -- - - -- - 12" x6" DI- TEE- 76+21 12" 45' I HORIZ STA: BEN 7+34 STA CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) - - I i 73+00 74+00 75+00 76+00 77+00 78+00 PROFILE VIEW HORIZ: 1 "=40' VERT. 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 03/27/20 C 90% DESIGN -NOT FOR CONSTRUCTION OW13120 B 60%DESIGN - NOT FOR CONSTRUCTION 02/07120 A 1 30%DESIGN - NOT FOR CONSTRUCTION 11/16119 REVISIONS v NISI M&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimereed.com 79+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES :; 8 81 +00 82+00 270 268 266 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 235 82+45 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL POWHATAN RD STA. 72+05 - STA. 82+45 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MISR. AJP a Cii III J 8' SCALE: 1 "=4' (Vert.) C8 SCALE HORIZONTAL: 1-=40' DRAWING NUN VERTICAL: D 1„_4, REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80—DRAWINGS\CIVIL\C.01-003580141—J000385—SHEET&BASE.DWG 03/27/2020 10:20:31 DAVID HAMMOND / I ' WF EO S, JOHNNY T JR M FAMILY INVESTMENTS LLC 021 POWHATAN RD 1025 POWHATAN RO /CLAYTON NC, 27527-0000 CLAYTON NC. 27527-9843 PIN' i687�M3-0221 p PIN: 16870MMW DB:O(2j�87 PG 0524 j 'L D804105�G.�829 } TEMP. S& FENCE (TYP. WHERE SHOWN, SEE/DE-TAIL EC-08 ON SHEET D7) PROP SE 2" PVC WATER LINE Lr) X 04 / 4SA00U Q r N/F RTr&M S INC •SMITHF:,7.e9-,"PIN_77�� , 1 PG 0113-., , r r I / I NEW FIRE HYDRANT ,, rrd. ASSEMBLY , STA: 85+22 r12 DI PLUG IL X I U V IGG 10" GATE VALVE TA: I8 +22 3 � STA: 85+30 o ..r 2 LS ,t 85' 00 u84+00 LSA 1— W _ - ''_ (R — — —— W(R) — — V) LLI W(R)--_—_. W(R)a-_ _ LLI V) / / WHATAN RD z w /`- / - SR 1901) tLl TV(R) — _ — TV R) _ R)—_— (n V(R)— --- _.—TV(R)--._— TU-- () T--Rl-=Tv(�P --- Tv(�p� — ==— TV — 280 278 276 274 272 270 268 266 264 262 260 258 256 254 252 250 248 246 245 REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 03/27/20 C 90Y.DESIGN- NOT FOR CONSTRUCTION 03/ 13/20 B ".I. DESIGN- NOT FOR CONSTRUCTION OV07/20 A 30% DESIGN- NOT FOR CONSTRUCTION 11/15/19 REVISIONS Q R LIMITS OF DISTURB CLEARING LIMITS (WIDTH ) i REMOVE EXISTING HYDRANT ASSE h \ \ L�RAUTREE RALPH J 80 \\ JACK s �YTOt7NC \ 9700-05234 jpB01 \ OB 0170 P0:0751 PLAN VIEW HORIZ: 1"=40' Irk STA: 85+22 PROPOS D 10" PVC WATER — — — _ _ TLRT �57�� T(�— ) / n /--�2'x8" BI TEE STA: 85+22 NECT TO EX. WL 10"x10" CUT —IN DIP 83+00 84+00 PROFILE VIEW HORIZ: 1 "=40' VERT. 1 "=4' e`-**1�MF1QA4&CMED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 85+00 280 278 276 274 272 270 268 266 264 262 260 258 256 254 252 250 248 85+42 JOHNSTON COUNTY DEPARTMENT OF UTILITIES N/F CRUMLEY, J RICK 1030 POWHATAN P O BOX 210 WILSON'S MILLS NC, 27593-0210 PIN: 168700-847558 / DB:01272 PG:0215 40' 0 40' 80' SCALE: 1"=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL POWHATAN RD STA. 82+45 - STA. 85+34 F NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS —OF —WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROD. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED ASP PROJ. MGR. ASP 11 d 0 J 8' SCALE: 1"=4' (Vert.) C9 IF SCALE HORIZONTAL: =40' DRAWING NUN VERTICAL: D REVISION ;TATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:21:14 DAVID HAMMOND � V - i / ___ (a)M-' - I --- - M )L EX. 78GATE VALVL 1�=DI TEE —FO(R — ' FO WF DOUBLE FAR LIMITED PARTNERSHIP V/ P 80% 101 / WIL DNS MIL\C,27593-DODD / - P/ p \ / I PIN: 1687a-10-8868 08:02001 P(i'.0927 NIF \ _ DUKE ENERGY PROISS, LLCA pV °V , 550 S TRYON ST DE 22A CHARLOTTE NC. 0-19 -420D / \ / PIN' 5322 G0537, I r/ WE I NIF O° X DB 05322 PG:053] — R CHARDSON ANTHONY RI�HARDSONHONY SR / \ h / 187 GOR RD id] GORDON RD .�.\\ 0v C PIN O 870D-21SE73B ..0 PYN ON N0, 27520-1743 ,1,68700-21-9262 5042 PG:0587 UP 05042 P 687 . p' °° I TEMP. STRAW W/ NET LINER I ; / I ow p° ��• 2- TYP� WHERE SHOWN, �/ SEE DETAIL EC-19 ON SHEET DS) ti / R) _ �- _ I / 16" GATE VALVE J R _STRAW WATTLE (1`YP. � / � �� ( WHERE SHOWN, SE DETAIL STA: 108+69 `wCR)'\ EC-18 ON SHEET 08) \ WO DEN 16"x6" DI TEE CR)a� V 'V STA 108+64 -lwJl TEMP, SILT FEN E (TYP. 1^} WHERE SHOW, SEE DETAIL EC-08 ON S EET DT) 102+00 J rlR)71- _ _ j\ _ _ W \ •'o — —\�sF °lam ,,. 103+p0 __ —� REMOVE -EX. PLUG CONNECT EX. LI DIP WL 6"X1 111 1 TEE c - --- °UOu �ON D 6" 22.50�DI HORIZ. BEND �� 1� 00 19 — 11006+00 " � ,- ;TA: 101+ 3Ou 105+00 e 1 L" a I 7 U \ J _moo - p° b+ NEW FIRE HYDRANT / 2" BLOW OFF ASSEM S :DI100+06 \ \ PROPOSED 16" DIP WATER LINE "Y -� o : 108 LY 64 Rs o° STA: +06 v� �i °u o° STA: 108+64 I �Q a6" 45' DI VERT. BEND \ SET: 1 \. N,P v S 106+47 LIMITS OF DISTURBANCE/ S' WI- �� O DDTDR, PATTIEB _ > - "-MITCHELL BETTY v ) \ 77oD N c ss Nlk x, . 16 45' DI VERT. B N CLEARING LIMITS (TYP.) z 7 GGRDGN RD SELMA NC. 27576-0000 ` - .' -`- STA:,105+63 _ 16" 45' DI VERT. BEND (WIDTH VARIES)` ( DLAYT Nc, z752o.0Doa PIN, i�a700-31-a7sD STA: 106+40 \ / PIN:1 700-11-5891 B OF: PG- \ \ P\ �16" 45' DI VERT. BEND ° STA: 105+69 / , SEE NOTE 5 (THIS SHEET)242 , SILT FENCE OUTLET (TYP. \ WHERE SHOWN, SEE DETAIL EC-12 ON SHEET D7) �V PLAN VIEW HORIZ: 1"=40' 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 224 222 220 I NEW FIRE HYDRANT-, - -- ASSEMBLY STA:-108+64 EX GRADE GIS) - EPTH APPROX.) (DEF 774 APPR FO X.) FO 42" MIN / . DEPTH APPROX. - 16"x6' DI TEE -_ -- 4"MIN ' 100+54 7A 6" GA VALVE x S 101+ 3 w 4& Do VER STA: 1 BEND 5+63 CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) X w 16 450 DI OERT. BE ND STA: 1 5+69 100+00 101+00 102+00 103+00 104+00 105+00 PROFILE VIEW HORIZ: 1"=40' VERT: 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 23/27/20 C 90%DESIGN- NOT FOR CONSTRUCTION 0311,120 B 60%DESIGN - NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/15/19 REVISIONS 10 e41*jWFM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License* F-1222 www.mckimcreed.com 106+00 107+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 108+00 I 1 - � I � /A I O RCP wS�)_ + rn Lo - J W Q 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 224 222 220 109+00 109+40 4-0' 0 40' 80' SCALE: 1"=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 100+00 - STA. 109+40 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. 5. LOW SPOT OBSERVED DURING FIELD INVESTIGATION AND NOT DEPICTED IN GIS SURFACE. DEPTH OF LOW SPOT SHOWN IS APPROXIMATE. CONTRACTOR TO USE VERTICAL FITTINGS TO CROSS THIS AREA AND MAINTAIN AT LEAST 42 INCHES OF VERTICAL SEPARATION BETWEEN THE TOP OF PIPE AND LOWEST POINT OF CROSSING. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358.0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 4 63 9 J 8, SCALE: 1"=4' (Vert.) SCALE C l O HORIZONTAL: 1"=40- DRAWING NUMBE VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80—DRAWINGS\CIVIL\C.01-003580141—J000385—SHEET&BASE.DWG 03/27/2020 10:22:00 DAVID HAMMOND MITCH ti4 - 2367 N/F CLAVTG y rAIJO§Ea,� I PIN.1 \I a , 2�t60R0f�dtD. \ '" 3 DL"AY1S-F,NC, 27320.8 . < •* •' PIN' 188700.21191 6 .. PG I 1A R Ii R I I z. 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 225 411EIN, \ WALL (TYPJ) / ,wC GOL B ETTY N GOB 1\ N 7 ' 2 20_0-0WO NIF \ t \ \ \ \ \ MITCHELL, BETTY L 2367 CLAYTON NC, GORDON7 20-OWO \ 1 PIN: 1687015891 PG LIMITS-- IMITS OF DFS7URBANCE/ CLEARING \LIMIT�TYP.) (WIDTH VARIES). \ \ — 112+00---w(R—\- "" -- 113+06 -- -- w(R} ' -- D(R) - _ 111� —�C - - _ - _ `\�-- �_ .- "sW(R}- FO(R) —�_ —FOR —._ — _FO(R __ 115+00 GO N RD R)- FO(R)- _ FO FO(R) \ —FD(R) --- T _ 117+00 7JTEMP. WHRE HOWN, SEE DETAILEC-18 ON SHEET D8)FENCE OUTLET TYP__—WHERE-SFTOWN SEE D TAILEC-12 ON SHEET D7) STRAW W/ NET Ull P OPO ED 16" DIP TER (nP WHERE -SHOWN; �\LINE 00 00 N 118+000 T ( j Q F- ILj - \ \ \ If n w w = \ \ \ Z LLI � J W \ \ \ NEW FIRE HYDRANT � \ ASSEMBLY �- TA �BEI�TAIL EC-19 ON SHEET D8) � � \ \ \ \ \ \ \ \ -� 118+57 \ \ \ \ \ \ \ MITC NLFBETTV L \ \ \ \ \ \ \ \ YTO GOR ON RD \ C 68700-20 1 PIN:O11000 \ \ \ \ \ \ \ \ \ DB: PG: PLAN VIEW HORIZ: 1 "=40' EW FIR RAN SSEMBLY 118+57 EX. GRADE (G/S 42" MI .. „ DI - STA: 118+ 6 -t - P VATER I CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) - 110+00 111 +00 112+00 113+00 114+00 115+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 03/27/20 C 90Y. DESIGN- NOT FOR CONSTRUCTION 03/13/20 B 60% DESIGN- NOT FOR CONSTRUCTION 02/07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11115/19 REVISIONS 10 e",,*j MFM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 116+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 117+00 118+00 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 225 118+80 40' 0 40' 80' SCALE: 1"=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 109+40 - STA. 118+80 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROD. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 4' 761 4 SCALE: 1"=4' (Vert.) SCALE c i 1 HORIZONTAL: 1"=40- DRAWING NUMBER VERTICAL: D REVISION 3TATDs ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.O1-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:22:45 DAVID HAMMOND \ +": T, —,--BLUE. HERBERT JEROME aN/F •. �f •- 551 CORDON RD \ T - DIXON TERRY D. s '' 513 CORDON RB" +--\—\\F— 1}., PIN. 168700-22-172fi ��LAYrON NC, 27520-7582 ! D8:04 1 FG: I9 PIN: 168700-22-2784 a e DB:05230 PG:0001 �� f• ( �— m \ \ MIT FGNIF LL, BETTY L (J/F r 2367 GORBOt\I RD �— / --� /C(MORE. tHY MICHAEL �'` ! �� CLAYTON NC, 27520 1-5891 00 CL469 AYTO ROON RO 0�— \ \ PIN: 16B700-115891 DB: PG: �� - PIN:1 765 4PG0—� p / \ COMPOST SOCK (TYP. �ERf-SHOWN, SEE DETAIL M I l _i / rRANT \\\ EC-1N SHEET D7) \ �_ / `� �w / /R u , SEMBLY \LIMITS OF DISTURBANCE/ SEE DETAIL EC-O6 ON 127+29 SEARING LIMITS (TYP.) SHEET D7 FOR SILT FENC ^WX rye\ \�pw TH VARIES LAYOUTJN PIT-COCAITONS i P SED "DIP WA R tl 4:. / 1 l / 1 PROPOSED TEMPORARY CONSTRUCTION EASEMENT c') `vim ^r' --- �\ i -� -�10" LAUNCHING PIT 16" 90' DI HORIZ. BEND STA: 122+99 / 7W, SILT FENCE (TYP. E SHOWN, SEE DETAIL R V� 16" GATE VALVE EC -OS ON SHEET D7) /� � 126+oO WCR)� 23+ STA: 123+ij6 W(R) L I _/ 124+00 125+0( o- R)/F6(RY's�� W( -G'w7c � � - - R)=. t 10 - R _ �H % I \ \ WF \\ \ GORDON RD YTO \ \ ttON 000 IN: 168 70 11 PG1-589t-589I \ \DB: PG: 268 266 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 /JACK AND BORE 43'LF OF 30" STEEL la)3 CA ING (11iICKNES 0_375") w/ 43 LF OF 1 " RJ DIP CARRIER PIPE / 16" GATE VALVE ISTA: 122+4 10"x1O" RECEIVING IT 16" 90' DII ST:HORIZ. 122+511 \ \ PROPIOSEDATEMPORARY I \ CONSTRICTION EASEMENT I TERRY, NYA WETTE I\ 28 P OROIA OR CLAYTON C, 2752 PIN: 16 700.2 720 \ \ DB:O 03 P83 yrc —W(R) GORDON RD _�-- (SR 1913) . ,Z SlR 0 / / O R 16"x6" DI TEE _—T(R)_ — �_--_ F OCRL F9 a T(R) T(R) -- /_ —'b.rfl o / JIA: IL/TL`J —ia)3_ RCP _ -„'ed'.`��Yi Z A \ / I ✓ Q 04 Ij 0 00 I / PLAN VIEW HORIZ: 1 "=40' ou // / STRAW WATTLE (TYP. � CONTRACTOR TO FIELD I /WHERE SHOWN, SEE DETAIL VERIFY LOCATION OF I / EC-18 ON SHEET D8) / EXISTING VALVE AND � R / ADJUST WATER MAIN w ALIGNMENT AS NEEDED TO AVOID CONFLICT / SEAMAN DA IEL ROLAND HAGGARD SARAH ELIZAB i / 17 PED DR �[ 506 GORDON RD [PIN:: °--8 CLAYTON NC, 27520 \ ! PIN:'168 89@ PIN: 168700.22-4987 p A DB:0463 00661I I K DB:04697 PG W9 .- (`a ", r„.. yam,.,-;{ y/ =' \ •t, BOYLAN, MARY LOUISE 540 GORDON RD CLAYTON NC, 27520.9828 PIN: 16B700-23-2193 DB0131 -:0447 A I -I I 3 - I -- - NEW FIRE -, STA: HYDRA ASSEM 127+ T Y 9 - - o - - - - c� . GRADE (GIS) 49" MIN (DEPTH A Fr PROXJ I I 1 I (DEPTH DIP WLPRQX.% p P COVER TYP. ) - i � -- - -�1--i- JI FU 1 { I — / --_ —."--- 10"xl,0" RECE VING PI i I — i i 1 1 11 - — i " GAIE VAL 18"MIN { I 1 1 I i j ",. " DI TEE STA: 122+44'', i ' i I, STA: 127+ 29 L-HOPOSED 16 DIP WATER _i 16" GATE VALVE---_ i .- - " I I 16" 90' DI HORIZ. ',BEND CONTRACTOR SHALL MAINTAIN CONSTANT GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) STA: 122+51 +z99 JACK ANDi BORE 43 LF OF 30" STEEL THEORE CAL 1:1 SLOPE CASING (THICKNESS 0.375" 16" RJ DIP CARRIER PIPE w/ 43 LF OF - - - 119+00 120+00 121+00 122+00 123+00 124+00 PROFILE VIEW HORIZ: 1 "=40' VERT. 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 7/20 22 C 90%DESIGN- NOT FOR CONSTRUCTION 03/13120 B 60%DESIGN- NOT FOR CONSTRUCTION 02/07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/16119 REVISIONS CARC •;Q�OFE5S107y9-•9 �'�: 049224 0. ���/1111111111YY\ �-U l7 J° v N140M&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 125+00 126+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 127+00 '128+00 268 266 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 \v 40' 0 40' 80' SCALE: 1"=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 118+80 - STA. 128+20 \1 1.NO CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP IIn ral Gf SCALE: 1 "=4' (Vert.) SCALE Cj 12 HORIZONTAL: 1 "=40• DRAWING NUMB[ VERTICAL: D REVISION ;Torus: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 0612112020 10:25:35 DAVID HAMMUNU 268 256 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 233 46 Sr \ N/F .., 6 � • \ \ \ H595 ,R GO DONR _ IN NIF ERBERT JEROME / \ \ PDS N772 PG 0818 1 / 551 RDON RD y�— CLAVT027520.758� PIN: t68700. 1726 DB04831 PG�o�ey/\TEMP. SILT FENCE ( 252' - IWHERESHOWN, SEE D TAIL I \ \ E -08 ON SHEET D7) TEMP. COMBO SILT/TREE /3 \ 1 /a STRAW ATTLE PROTECTION FENCE (-- WHERE SOWN, SEE ETAIL \ WHERE SHOWN, SEE'bETAIL \ IP \ _ / \ EC-18 ON�SHEET�� EC-10 ON SHEET D7) 00 A i 133�+00 130+00 \ 132+00 — W( 131+00 O / / - N/F < ' PARKER, GARLANO'6_ 61560 D / CLAYTON;N 520-7585 PIN: 16870 12�769 D13:04 30 PG:0493 t;PROPOSED 16" DIP WATER E 1 F \ O I 1 g v � 136+00 37+00 134+00 V 35+00 / a -W I — _ -- _ ---- R7 -- GO W(R)-----W(R)---- CFO �7CR) cU � _ — F'O" �rT(R) BOY ARY LOUISE , 540 GORD NRD WF CLAYTON 27520-9828 STANLEY, R TH UZZLE 4 \ OV LSA \ PIN. 1687(0 1071 POBOX22 DB04561 PG 04 WILSONS MILL C, 275930000 PIN: 168700-23q 3 \ D13:03257 Pc:oee \ I \ i F JO ? AN C. � \ LAS L 00.23-0180 8 PG 0039 \ -W(RI j- = _ _W R_ GORDON RD- - - - I (SR T3)_-= --T( )-- _--- -_- O-- --- F — — — For FO(R) — — — FO(R)— — FO(R) / LIMITS OF DISTURBANCE/J / Xk \ \ CLEARING LIMITS (TYP.) (WIDTH VARIES) OU�OUoU OU OU 00 OLDS, LIF RHONDA \ i 1 \ . \ } '„✓ \ ! y V 1 ELLAS LN \ CLA Nr.0,6 C, 2757142 \ \ \ PIN: 16 0-G01372 DB04299 G0137 2S PLAN VIEW HORIZ: 1"=40' ,70tm) 191 t I � R)-- =--F— � —F 2P- --FO(\ — 4(R) — —OU 0 o0 RANSO ISTII4E n 1- Q co 23 BjA YWO DR 75 ° CLAHTON NC 27 47531 //P IN. 168700-1"103 ,� / _ / DB:04740 PGt687 5 O \ c0 -F \ �U _ W _ LLLI J = Z_ 0 J W _0 U F- FO(R)-- -. EPTH AP ROX.) U zEL Fr (DEPTH PPROX.) Ci EX. GRA E GIS p U 2" MIN— _ CO R TYP. " DIP WL EPTH APPROX.) - — \ _ (DEPTHo. - -- \ -- �- DIP WAFER LINE OP SED 16" CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) --- -- 129+00 REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 03127/20 C 90% DESIGN -NOT FOR CONSTRUCTION 03/13120 B 80%DESIGN- NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/15119 REVISIONS 130+00 131+00 132+00 133+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' v NFM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 134+00 135+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 136+00 137+00 268 266 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 234 233 137+60 40' 0 40' 80' SCALE: 1"=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 128+20 - STA. 137+60 NOTES 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP G! d U J 8' SCALE: 1 "=4' (Vert.) SCALE C 13 HORIZONTAL: 1-=40- DRAWING NUMBER VERTICAL: D 1,.=4. REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80—DRAWINGS\CIVIL\C.01-003580141—J000385—SHEET&BASE.DWG 03/27/2020 10:24:15 DAVID HAMMOND 260 258 256 254 252 250 248 246 244 242 240 238 236 234 232 230 228 226 225 N/F �- PARKER, GARLAND C / / I \ 675 GORDON RD N� C LAYTON NC, 27520.7565 POP R C5 GREENLYNDEVELOPMENTCO 145 GREENLYN DR PIN: 168700-12-0769 / � CLAYTON NC, 27527-5064 D6:04630 PG'.0493 I ( �' I / / / PIN: 167700.92-3 \ 16" 11.25- DI VERT. BEN 1 j ^ / / DB:D4T .MSS STA: 141+9, SlP(EAM 9 Toe / / \\ 1 10'x10' EXIT PIT / SILT FENCE OUTLET (TYF. / 16" 45- DI HORIZ. BEND �' /WHERE SHOWN, SEE DETAAhjL STA: 141+73 EC-12 ON SHEET D7) STRAW WATTLE ti A PROPOSED PERM/ANENT —4C" 14 t• V. nI vror �VKIM uucor cunuml crr %7TeN 00 Or STA: 144+76 9 16" 45' dt HORIZ. BEND / UTILITY EASEMENT IV "'`"' "" LL4 "V" STA: 141+40 1 j STA: 1t44+27 / EC_'- ­' ON S/ ET \' "10'x ENTRY I/IL 16 GATE VALVE / P PROPOSED TEMPORARY STA: 141-T•37 t42+o0 CONSTRUCTION EASEMENT 16 45' DI H�RIZ. BEND /J NF \ /'/ I - _ ��1- ��• f-�.� �•-�� N / STA. 1 44+46 STA�EY, RUTH UZZLE / PO BOX 222 /6-/ 144i•QQ / " NALS S MILLS NC, 27577-0 22 141+00 16 5' DI HORIZ. ,BEND PIN:16e700-D3ats2 I TEMP. COMBO SILT/TREE 44+76DB:D4z47PGo371 PROTECTION FENCE (TYP. D WHERE SHOWN, SEE DETAIL FAO+O ST 1 EC-10 ON SHEET D7 W( — PROPOSED 16" DIP WATER LINE r NU1=24166 PROP,OSED TEMPORARY \ ,39+DO __��- ": --'I _ � — — -� a� IN✓.=24�5 ---__ _ �"�' - -- _ ��CQI�ISTRUCTION EASEMENT 42�� - W t46+00 ,se+p0 Rp /249� _� ]% xY N 4 — -� v iSR R� (SR Y / IN v 243 39' I - �J j 9 _ FoIR)'� STRAW�TILE (TYP. � 13� WHERE SHOWN, SEE DETAIL lN��rag.ss' EC-18 ON SHEET DS) r �� -TEMP. SUPER SILT�FENCE - � SEE DETAIL EC-06 0 'h ' L SHEET D7 FOR SILT FENC � I (TYP. WHERE SHOWN, SEE �' I CONTRACTOR HALL �� � - - LIMITS!' OF DISTURBANCES ll / ) LAYOUT IN PITILOCATION S� ETAIL EC 11 ON SHEET D7) 1 / MAINTAIN 2' SEPERATION - CLEARING LIMITS (TYP.) 24a � � BETWEEN EX. ,FHA AND � \ (WIDTH VARIES) NEW 16" WATER MAIN. � o wgltANo 4 REPLACE BLOCKING AS REQ'D. / I I o COMPOST SOCK (TYP. [ �----"-•��� � ` 16" GATE VALVE WHERE SHOWN SEE ETAIL I wP d/ I STA: 144+SQ RANSOM CHRISTIPE \ `EC-15 ON SHEE D7) �LAVTON NC 20752Q-7531 PIN: 168700-13- 03 \ � D6:04740 PG: e] I �Y� I � 1 GLOSS, ROD MAXWELL SR O eOOG GORDON RD CLAITON Q 27520.9629 PIN:1 700-035237 I I DB: 16 PG0612 I PLAN VIEW HORIZ: 1"=40' tA z I I 26 I � - 25 I I I I I I Ex. t 25 N N / 25 k W � OQ � 25 \ Z Ex GRADE is 10'x10' ENTRY IT 25 24 10'x10' E T PIT I I I 24 zBl �-- J I 1 "GATE VALVE 24 — I I (SUR Y) 24 16" GATE VAL 6` 45' I HORIZ. BEND 24 23 23 I CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) STA: 141+ 3 i STA: 144+27 " CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID STA: 141+9 INTERMEDIATE HIGH POINTS (TYP.) 23 � - =400' R 400' ' I 23 PROPOS D 16 SIBLE 23 22 22 22 138+00 139+00 140+00 141+00 142+00 143+00 PROFILE VIEW HORIZ: 1"=40' VERT: 1 "=4' REV. NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 03/27I20 C 99%DESIGN-NOT FOR CONSTRUCTION 031131M e 66%DESIGN- NOT FOR CONSTRUCTION 02/07120 A 30% DESIGN -NOT FOR CONSTRUCTION 11N6H9 REVISIONS `��11nuINu��� AL 5 9224 eN tom`•.• : �2: e ��&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 wvvw.mckimcreed.com 144+00 145+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 146+00 147+00 LL 40' 0 40' 80' SCALE: 1"=40' (Horiz.) 0 8 s 4 2 0 8 6 4 2 0 B 6 4 rel 7 0 B 6 5 - JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 137+60 -STA. 147+08 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHA BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: `��11nuINu��� AL 5 9224 eN tom`•.• : �2: e ��&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 wvvw.mckimcreed.com 144+00 145+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 146+00 147+00 LL 40' 0 40' 80' SCALE: 1"=40' (Horiz.) 0 8 s 4 2 0 8 6 4 2 0 B 6 4 rel 7 0 B 6 5 - JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 137+60 -STA. 147+08 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHA BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 4' GII J 8' SCALE: 1"=4' (Vert.) SCALE C 14 HORIZONTAL: r'�o 'STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.O1-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:2S:00 UAVIU HAMMDNU 270 268 266 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 235 PLAN VIEW HORIZ: 1"=40' 0 z � NEW FIRE HYDRANT \ - ASSEMBLY TA: _153+00 EX GRADE e CD - -- - -- Ir� - I - i i - (G/S) (DEPTHAPPROX)I i (DE TFAPPR LE X.) -- - I DE (GS) / I II EX- ENDING-ITH- R/ S- IDE 42" MIN 1a-MI --- - - DEPTH PPRox OF RCP CROSSING OVER ( .) E 16" STA- 6" DI 24"MI - I- - - - ,- 153+ _ - - 6" ATE VIA_`'_ 113" GATE 151+29 VALVE _ -C- S A: 150+ 9 i I STIA: 16" 90' DI HORIZ. or. D --- ST•At905 " I HORIZ. 23 BEND _ - UPWARDCGOR SHALL MAINTAIN CONSTANT RADE TO HYDRANT TO AVOID - I JACK AND, BORE I 8 LF OF' 30" STEEL - TH oREncA� INTERMEDIATE HIGH POINTS (TYP.) 1 " RJ DIP CARRI R PIPE CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) 148+00 149+00 150+00 151+00 152+00 REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING - NOT FOR CONSTRUCTION j 03127/20 C 90%DESIGN- NOT FOR CONSTRUCTION 03113/20 B 50°/. DESIGN -NOT FOR CONSTRUCTION 02107/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11115/19 REVISIONS PROFILE VIEW HORIZ: 1"=40' VERT: 1"=4' v NTIQM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 153+00 154+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 155+00 156+00 40' 0 40' 80, SCALE: 1"=40' (Horiz.) 270 268 266 264 262 260 258 256 254 252 250 248 246 244 242 240 238 236 235 156+48 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 147+08 - STA. 156+48 ill NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROD. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP a 1 a J 8' SCALE: 1"=4' (Vert.) SCIDZAL : C 15 1" VERTICAL: 1 =4 JD REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:25:48 DAVID HAMMOND N11 DOUBLE Z FARMS LIMI O PARTNERSHIP / I /F II P O B X 107 / / DOUBLE 2 FARMS IMITED PARTNERSHIP / WILSO IN 01 MIL NC, 27693-0000 WILSON M01S NC,12]693-0000 PIN:1 ]00-04510] DB:02001 PG:0927 P 168700-045107- / /DB.02001 PG:0927 /�h� ou 0U 1_ � -ou ou/� ou�u ou� ouoU ou ou ou ou o�o� ou\ ou — �a nlnu- 4 LIMITS OF DIfUR ANCE/ \ CLEARIN LIMIT (TYP.) ' \ /(WIDTHIVARIES) 00 M(R) _�y//L___�ccTT__ J—.— + W(R)---- 16�Rll/H"—W(R)---- �R)— /-W(R)-------W(R)—_--_yy(R) T7(R)-lh 1J/L'—W(R)-----W(R) ——_14�R)-- _-1VtR)— —_ �R)—--y/�R) -- _yKR—_y/�R) — _1N(R)1 - L 0 1s7+0o 15s o SR 191 3 159+000 � oo 1 1+00 _ 162+00 163+00 — \ 164+00 Q --- --- --- -- �- —� - -- --- - - - Un)W -_—. - —. —. — — Z J IW UN \ \ AL COMPOST SOCK�TYP WHW SHOWN, SEE DETAIL EC�O SHEET D7) 00 --W(R)----�r(R�— a—�1TR)— W(R) — — + 00 cU0 n T- U -- ---m H F- - T(R) - - - - T(R) - - (n W LLI = Z to 1I \ TEMP. SILT FENCE (TYP. I \ \ F Q \ WW ER SSHOWN, SEE DETAIL -_ _ EC=08� SHEET D7) �6� \ \ ABANDon�EosrRUCniR77�� \ \ STRAW WATTLE (TYP. SILT FENCE ITLET (T� \ \ \ \ \ ERE SHOWN, SEE DETAIL WHERE SHOWN, SEE--0 IL \ \EC-18 ON S W -DR}- ---- EC-12 ON SHEET D7) \ \ g \ \ \ \ \ \ \ \� PROPOSE 16 DIP WATER LIE \ f �s� \ x \ \ \- \ BLE2F ER DOU , I/F UP� HW XC NIF \\� — \, '' y L ONN MILLS -04-51 000 \ \ V.. \ DOUBLE Z FARMS LIMITED PARTNERSHIP _'" _\ \ \ \ \ -- S PI8:020000-04-5107 \ �_ _ . \` /-- -�_ \ `-ia `:�:'i",= \ \ D8:02001 PG:0927 P 080X 101 IMLSO IN MILLS NC, 27593-0000 PIN: ILLS C, 2759 \\\ 04-5107 DB:02001 PG:0927. pp PLAN VIEW HORIZ: 1 "=40' 274 272 270 268 266 264 262 260 258 256 254 252 250 248 246 244 242 240 _ 1 i � I i i 2" MIN -- COVER TYP. PROPOSED -16"-DIP I CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) i I 157+00 158+00 159+00 160+00 161+00 162+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1"=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 03/27/20 C 90%DESIGN-NOT FOR CONSTRUCTION 03/73/20 8 60%DESIGN- NOT FOR CONSTRUCTION 02/07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11/15/19 REVISIONS 00 .ZN I......... '%�. �� �:Q�pFESS10 '9 !� SEAAL 049224 elit gF -0. 1$ MFIQW&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 163+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 164+00 165+00 40' 0 40' 80' SCALE: 1"=40' (Horiz.) 274 272 270 268 266 264 262 260 258 256 254 252 250 248 246 244 242 240 165+88 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 156+48 - STA. 165+88 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP a C 0 J 8' SCALE: 1"=4' (Vert.) SCALE C 16 HORIZONTAL: 1"=40' DRAWING NUMBER VERTICAL: D REVISION TATDS ISSUED FOR PERMITTING NOT FOR CONSTRUCTION 1:\00358\0141\WATER\80—DRAWINGS\CIVIL\C.01-003580141—J000385—SHEET&BASE.DWG 03/27/2020 10:26:33 DAVID HAMMOND \ / N/F fQ� DOUBLE Z FARMS LIMITED PARTI 01 DOUBLE Z FAR OLII MIXED PARTNERSHIP / / /11� / WILSONS MILLS NC 27593-( WIL PIN: ILLS NC, 275 3-0000 / �� -- 101 PDB:02001IN 0 G409270 IDS 02001 PG:0927 / / OU OU—Af --ffr �OU�� OU OU OU OU OU 0 OU — 00 00 — ,}----W(R)— __—W(R)___—W(R)--- co co U 166+00 167+00 I- --—�>---- W—TR)—_---T(R)—---T(R)--- — R = — z cn PP © I I� � U OU OU OU Bf'Fi-- OU— COMPOST SOCK (TYP. \ WHERE SHOWN, SEE DETAIL _.�•I5,ON SHEET D7) \ ` RA �— LIMITS OF DISTURBANCE/ \ 1 \ST ERE SHI TLE ( 16' x " I-- w CLEARIWLIMITS (TYP.) — ON SHEETED,` \ / ^\+27 \_ (WIDI}KVARIES) —'W(—_W(R)_—_L—WAR,=�_ W(R) W(R)--_—WtR)_—_—_V1�R) __— 1Y(R)— — Wr���---`y(R)--___14(R)_—___N GORDON RD 168+00 __�SR,1-913) 169+00 / 170+o0 171+00 172+00 173+00 — — — — — T(R) -- - TFR) (R) +h "�\Y(+� ) T \� — -jw U \ \ TEMP. SII(T FENCE (TYP. I Q \WHERE SHOWN, SEE DETAIL 17 EC-08 ON SHEET D7) 282 280 278 276 274 272 270 268 266 264 262 260 258 256 254 252 250 248 166+00 I 1 P OP SED 16" DIP WATE U J I N/F I \YYV DOUBLE Z FARMS LIMITED PARTNERSHIP ' PO BOX 101 I ' WILSONS MILLS NC, 2759$-0ow PIN: 167700A4-585 I\ DR02001 PG:0927 I I J \ I / \ I \ _ 04 --�� N R)_____W(R)�----W(R)__--W(R)_ ——W(R)-- — W + -174+00- ---- 175+9.Q U a l- W Lil 2 cn / \ �� LLj V) NEW FIRE HYDRANT) \ " * , SI YFENCE OUTLET (TYP. ASSEMBLY E SHOWN, SEE DETAIL \ I— STA: 171+27 / STRAW W NET LINER --- J / / EC-12 ON SHEEN) (TYP. WHERE SHOWN, \ /EE DETAIL EC-19 ON SHEET D8) I% DOU LE Z I I FARMS. PARTNERSHIP / OBox 10 \ LSQ IN MILLSSNC,NC, 27593-0000 I / : 167700�53 013:02007 PG'.0927 PLAN VIEW HORIZ: 1 "=40' EW FIRE HYDRANT ASSEMB Y - EX GRADE (IS) - — 420 MIN i — C VILK (I TV i — 16 x6 DI E CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) - 167+00 168+00 169+00 170+00 171+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 03127/20 C 90% DESIGN -NOT FOR CONSTRUCTION 03113/20 B 60%DESIGN - NOT FOR CONSTRUCTION QJ07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11115119 REVISIONS r' �pFESS/0 ' 04EAL = .:co ` '.��d1�••. FNGINEE`�••'����� 0. v NIFMM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 172+00 173+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 174+00 282 280 278 276 274 272 270 268 266 264 262 260 258 256 254 252 250 248 175+00175+23 40' 0 40' 80' SCALE: 1 "=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 165+88 - STA. 175+23 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS —OF —WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MICE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 4 C 4 SCALE: 1"=4' (Vert.) SCALE C 17 HORIZONTAL: 1"=40' DRAWING NUMBER VERTICAL: D 1..=4. REVISION >TATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80—DRAWINGS\CIVIL\C.01-003580141—J000385—SHEET&BASEDWG 03/27/2020 10:27:18 DAVID HAMMOND 14) N n r U F- H N W W W = Z U) J W LLI U to F_ Q 292 290 288 286 284 282 280 278 276 274 272 270 268 266 264 262 260 258 257 00 co 000 T r U H~ V) W Lir Z J W W 2 V) H a PLAN VIEW HORIZ: 1 "=40' I (G S) NEW FIRE HYDRANT- I � cD � i _ X -GRA E-(GISZ - - 11 N GAi VALVE - _ - - --- TA: 18 09 -'-18" RCP / 2" MINCO - VEK X 3f _ CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) 4"MIN _ 176+00 177+00 178+00 179+00 180+00 REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING - NOT FOR CONSTRUCTION 03/2]/20 C 90% DESIGN- NOT FOR CONSTRUCTION 03/13120 8 fi0%DESIGN-NOT FOR CONSTRUCTION OV07120 A 30% DESIGN -NOT FOR CONSTRUCTION 11/15119 REVISIONS p�j� I CARp<Gy'�. �.Q01LSS104,,9' . 9 ''• �EA24 - %�cP�••. FN6INEE�.•�Z�� ���/nnnull�a �yd PROFILE VIEW HORIZ: 1"=40' VERT: 1 "=4' v NI�I�/I�CIZEED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 181 +00 182+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 183+00 184+00 40' 0 40' 80' SCALE: 1"=40' (Horiz.) 292 290 288 286 284 282 280 278 276 274 272 270 268 266 264 262 260 258 257 184+68 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 175+23 - STA. 184+68 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP d I J 8' SCALE: 1"=4' (Vert.) SCALE Cj 1 8 HORIZONTAL: r•=40' DRAVNNG NUMBER VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:28:03 DAVID HAMMOND 312 310 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 278 277 i PLAN VIEW HORIZ: 1"=40' // / /. 40' 0 40' 80' SCALE: 1"=40' (Horiz.) ASSEMBLY LE STA: 194+07 a EX. GRADE (GlS) -- - / --- ---- _ -- _ --_ -, - ---- -- - -- (DEP H APPRO .) - -- - �! - -- 16"x6"-DI TEE / TA: 194+07 o / / eI ` - CONTRACTOR SHALL MAINTAIN CONSTANT - —"— - — UPWARD GRADE TO HYDRANT TO AVOID 42" MIN INTERMEDIATE HIGH POINTS (TYP.) � COVER TYP. - - i0-71 (DEP APPRO!) i / I 312 310 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 278 277 185+00 186+00 187+00 188+00 189+00 190+00 191+00 192+00 193+00 194+00 194+45 REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 03/27/20 C 902E2IG2- NOT FOR CONSTRUCTION 2 03/13/20 B SO%DESIGN - NOT FOR CONSTRUCTION 02/07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11/19/19 REVISIONS 00 o\`.o\�N IC...... ,�� �: Q#IsS//p 9 !^ / SLRL' 049224 ,�y••.......� inn 0 PROFILE VIEW HORIZ: 1 "=40' VERT- 1"=4' e44*�,McM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com JOHNSTON COUNTY DEPARTMENT OF UTILITIES JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 184+68 - STA. 194+45 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 4 0 J 8' SCALE: 1"=4' (Vert.) SCALE Cj 1 9 HORIZONTAL: 1 "=40' DRAWING NUMBER VERTICAL: 1„=,. D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:28:51 DAVID HAMMOND I 111 o' " J JONES JOSEPH9 PO 60' "' / /LAWON NC, 27528-0871 PIN 01628 -G 00012 DB 01628 PG:0001 I / O o P i _ )----W(R)- -- W(R) 'R) --W0 NIF / ADKINS, C 48 EDDLE O CL PIN: 1 0, 2752 PIN:i 70, 75275 DB' 4650 PG:0424 COMP9ST SOCK T'4P E SHO EE DETAIL EC-15 ON ,SHEET D7) - /� / L RICK 1 ffi9 DLESTONE CT I C ON NC, 27520-75 / I // DB:04327 PG:Oj51 / / / /REMOVE t535 J F" OF EX. PVt 15 STA. 4+80 - STA. 2 +15 I _ ANGOON, ENNVHAROL / 6" -GATE VALVE S VJIC 11V SCOT tg�,/ \ ILNIF 7 EDDLES}ONE CT� N. 19 SLATEFORD 0 STA: 204+81 I LAYTON NC, 27. 25 0 g� ♦ ' r' / %S' CLAY70N NC, 27D20 i lI ^ I PIM167700-76 0 / / / PIN:11 6, 9p' DI HORIZ. BEND- W DB:04333 P 58 'W 04428 PG:0575 STA: 204+91 OFFSET: `8' (ROLLED AS REQ'D)� 61, 11 DI STA: 1 OFFSET: 8' I { / "9 1, _#C01-1-6 AS REQ'D) ----- W(d-----W(R1--- W/Rl-----W(R) /—WR)--z—W(R)---- = W(R) — — — — — ---^— _I — R — — — —WR,.FL — ----WAR)----- )--- —i`' U) D3 I 1 I O 00;U 0 3 II 1' II 0 II I � I I I 1 � 1 6"i71 PLUG I Illy\ TA: 204+82 ,? G G DON RD — — / 6" DI CAP : 204+8 199t00 (SR 11913) 2oo+oo 1201+00s0 4+00 — �— T(R --_ _ _ _ -/-—T/R1— f _-� .-.am D I RJ/-- V I / I / / / ✓ / __ - - - STA: 2TEE 0_ 44 = cn I H U oU -ou OU ou u ou / / i / I % U (n (w ou—�u ou U ou-auu— ou � �`uT/ ou LLI LLj Q a / �— " 0 Ou oU I LIMITS -OF DISTURBANCE /8------91----_ _Z N / / �', J / / / / / / 6 _ _ _ -e,«_ _ J 16" GATE VALVE -1 W I / / I i��k / � ROP ED 16 DIP WATER LINE / / / / / ¢LEARIN( IMF VARTIES) / WETLAND- 5__� TEMP. SILT FENCE (TYP. STA: 204+96 J {f WHERE SHOWN, SEE DETAIL �- EC-08 ON SHEET D7) / I WHERE SSHOWN,, E DAW WATT� ETYP.� / / / / / / / �E � T / Q / \ EC-18 ON SHEET D8) / �MP. SI�ENCE (TYP. 9ti i 16"x6" DI TEE R151,l" WHEf2E SH WN, SEE DETAIL / NEYV FIRE HYDRANT STA: 204+91 I / `� / / EC70 ON S EET D77� / % / ASSEMBLY \ \ i �STA: 204+29 /SILT FENCE OUTLET- (fYP. w I ERE SpIOWN, SEE DETAIL 18 45' DI HORIZ: BE WOODA BETTV C /WH 2t�-9 2RFG(LABTOWN ROAD / / / E -12 ON/tHEET D7) / STA: 204+46 I —S MITHFIELD NC, 2757741000 PIN:16770PG:05 a 16" 45' DI HORIZ. BEND DB:012]0 PG:OS CHELLFBETTYL I / \ STA: 204+58 I ONGORDON RD NOVON DISK PI GOOR0-77_74-95HARMACEUTICAL N✓ 1 6 2700 I _� rl>'»lll ___ 3612 POWHATAN RD CONTRACTOR SHALL 74IIX_ LAYTON NC, 2752760000 / INSTALL AND TEST NEW 8:014B6 PG:0� / I/ / / / / POB:04706 PG.02j WATER MAIN AND COMPLETE TIE-IN PRIOR TO REMOVING EX. 6" PVC WL./ N \ \ \ PLAN VIEW 40' 0 40' 80' HORIZ: 1"=40' SCALE: 1"=40' (Horiz.) 312 310 312 308 I 310 308 306 _� - 304 306 304 302 300 298 _ - 42" N \ 300 298 296 294 296 - - 292 - - --- --- - - �_ NEW Fl _ S E HYDR -HYASSEMBLY TA: 20 NT ... _ _ . - 29 294 290 288 CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) - - - (DEPrH APPx)I 290 - 286 284 - - - - — !_ - -- 24" -- IN (I Q EPTH AP ROX) 16"GTE STA: 288 286 VAL 204+ 6 282 STA: 20 45' DI 29 284 1 280 I 1 ¢" - I " 45' DI HORIZ. 'STA: 20 BEND +58 16 x6 T�' „ DI TEE 204+9 f - 282 --- 278 280 277 278 277 19b+UU 196+00 197+00 198+00 199+00 200+00 PROFILE VIEW HORIZ: 1 "=40' VERT. 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FORPERMITTING-NOTFORCONSTRUCTION 03/2]I20 C 90%DESIGN- NOT FOR CONSTRUCTION 03/13I20 B 60%DESIGN - NOT FOR CONSTRUCTION 02107I2. A 30%DESIGN - NOT FOR CONSTRUCTION 11/1611, REVISIONS r � \A CARO ,,,,,,,, ........... �� �:Q�pFESS10 � SEAL 049224 iCo v NI MM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 201 +00 202+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 203+00 204+00 205+00 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 194+45 - STA. 205.57 205+57 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 11 !9 J 8, SCALE: 1 "=4' (Vert.) C20 SCALE HORIZONTAL: 1"=40- DRAWING NUMBE VERTICAL: D 1,.=4. REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:29:35 DAVID HAMMOND IF 24 1 I a�ee.s \ V �� .; • �.� NIF SLATEFORD DRN/E \ i C PNONNC 27 ` ♦ - I \I \ \ `NTILLAN C lo NUDIA GONZAI EZ DB:03460 PG:W20 r".i" SEIGH, AARONAUGUST (.�3'. 1, `. 103 GRANT RCOURT a... 86 GRANTON CT V P- 3 LAYTON NC, 7520-0000. CLAYTON NC, 27520.7509 '/� \ ", SILT FEIV CAE OUTL T ( •\, � IN: 1677 - 6.9864 PIN:787700.68-3784 I \ , WHERE SHOWN, SEE ETA) 1. 1' `\ • �\ DB: 16777-66-375 ''4 \ -p.'.- B 03426 PQOBA9 no 1 / N/F2so� \ EC-12 N SHE T D \ TEMR SUPE� SILT FENCE c TYP. yyHER SHOWN ,SEE 102TON COURT, CLAYTONNC,2752o-0YDD \ I I \' \ DETAIL �C-1� ON S_HET D7) PIN: 1677W.W3895 LIMIT OF DISTURBANCE/ t DB:03538 PG:o554 \ ° j CLEARING IMITS (TYP.) SEE DETAIL EC 106 ON l ( DTH VARIES) I I \ SHF�ET DZ FOR SILTFENC COMPOST S�(TYP. " F�VC WL L/N'OUT IN t LCATION LOC _ REMOVE ±535 LF OF EX� 6 HEAawaLC 1 \ STA. 204+80 - STA-1jp+15 ) WHERE SHOWN`;, SEE DF,�TAIL / 3 % I / I �� McRo (NV-273.a5' - ` EC -4 ON SHEET D7 _ _ __-a)oe— --e o --�' --- - ----. — — O I W(R) w(R) JJ 16'rDIP W , )-F�(IR'1 LLn — �Ea)°e --- -- (a)es-- �' - _ - - - _ - - - W R -W(R)9�0+00 10 x10'. EXIT P �T �- ABANDON IN, PLACE + 3" DI GORDON — f�20 'LF OF DIA/!1(AT/UT1L10"(10'- Et<tTRY PIT' \ ----- - N — — 208+00� (SR 191� STA. 210+20 -STA. 213+40 y_ . '. - U I 207+00 -_- _ -__ _ - eB. _ - °v1§ , F (R - - H- Q ->�->` �- — _ _ � �.. - F R)�: � �� � � 212+00 � �W ' �E -. "e' /- � � ` � N _ .fi_ N N 213+00\ U TZ ZN -- --_ . / / 1 ou_ -- --xes �` 16" 5' DI ORIZ. BEND - - - °u _ r � w J LLJ w < o _ \ u S A: 210 02 ou ou o QL -- 4^ «' tea--_ -'-mot- 4 1 L w = _ l �/` _ r\_ z� / ou \ °U�ouo 16" 11. 5' DI/VERT. END '"`coca rloN APPR A )\ __ Z w �� /STA1+09� w T 1 ou °u I PROPOSED 6" DIP WATE LINE 16" 45' I HORIZ. BEN y I \ STREAM 1 TOB ou —OU Q STRAW WATTLE (TYP. I I STA: 210+1 WETLA�D s -- < WHERE SHOWN, SEE DETAIL / 1 \ EC-18 ON SHEET D8) I I / / i I \ 6" 11.25' DI VERT. 16ND t o r \ STA: 21 +44 v 28 \ STONE FILTER PIPE INLET N ) I ' \ + EnON (TYP. WHERE SHOWN, SEE DI % 16"STA: 213+53 GA VALVE / \ \ SEE D \ ' I I I I / ' / \ - _ / TAiC EC-16 ON SHEET D8) / EX. WATER LINE T BE % `279 ABANDONED IN PLACE. SE / INSET 'A' (THIS S �E / \ I NOVO 36R2POWH}dA;RMTAN ACCEEUTICAL \ I CL PIN 16 NC.♦'G702W 00 I I I I I I � � • I I � / / \ PIN: 167700 7-0644 DB:04706 / \1 j PLAN VIEW 40' 0 40' 80' HORIZ: 1"=40' SCALE: 1"=40' (Horiz.) 294 292 290 288 286 284 282 280 278 276 274 272 270 268 266 264 262 260 7n l Zk cD HORIZONTAL DIRECTIONAL DRILL ±292 LF STA. 210+82 - STA. 213+74 TELE DEPTH PPROX. \ (DEI TH APPROX.)42 > o COVER MIN (TYP.) 0 o a. \ N ci o (DEPTH ER-0130SED E MIV 2 11 18" IN i I o - ► ^N I� le (DEPTHAPPROX.) CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) r I I i STA: 210 02 EX. GRADE (SURVEY) ' I 18"MIN STA: 11+09 i STA: 2 3+44 -' 10' MIN \ R= 0 R= 0 i \ OPCWA R i10 6" GA VALVE STA: 13+53 206+00 207+00 208+00 209+00 210+00 211+00 212+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 23127/20 C 90%DESIGN- NOT FOR CONSTRUCTION 03113/20 B 80%DESIGN- NOT FOR CONSTRUCTION 02fov" A 30%DESIGN - NOT FOR CONSTRUCTION 11116119 REVISIONS SEAL 049224 cj 0illli�l��`��` oY" v NFM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimereed.com 213+00 294 292 290 288 286 284 282 280 278 276 274 272 270 268 266 264 262 260 213+90 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. 0 U 4 -m 8• SCALE: 1"=4' (Vert.) JOHNSTON COUNTY DEPARTMENT OF UTILITIES Oft- 00 cam,_ �•,s��. ^c ; L.,�s 8 8 _ 4 6 S 2 CUT AND CAP EXISTING 6" PVC WATER LINE W/ (2) 6" PVC APS INSET A 100O 100' 200' HORIZ: 1"=100' SCALE: 1"=100' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 205+57 - STA. 213+90 PROD. START DATE: 2019.NOV MCE PROJ. # 00368-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP SCALE C21 HORIZONTAL: 1"=40• DRAWING NUMBER VERTICAL: D REVISION r US: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION , I:\00358\0141\WATER\80—DRAWINGS\CIVIL\C.01-003580141—J000385—SHEET&BASE.DWG 03/27/2020 10:30:35 DAVID HAMMOND O 0) N N UI 06, Lj BETTY L 2367 GORDON 367 GORDON RD CLAYTON NC, 27520-0 00 PIN:167700-56-1770 DB:0m53 PG:0045 Pp G.3STRANSFER JACK AND BORE 76 LF OF 30" STEEL COMPOST SOC TYP. CASING THICKNESS 0.375+' w 76 LF OF TEMP. STRAW W/ NET LINER E DE 2 i w RY WHERE SHOWN SEE DETAIL oG , ( ) / (TYP. WHERE SHOWN. '- — - N 46_.BJ,DIP CARRIER PIPE EC-15 ON SHEET D7) ° 00 / SEE DETAIL EC-19 9N SHEET DS y. _( _ _ �� y A- o ` STRAW WATTLE 10 WH RE -SHOW ,, SEE DETAIL �� � fo= =- C4 N 'EC-18 ON SHEET D8) _ /=F-(R� ..� — W(R) U) T++_++ DI Ro 2I,-6 R (R)— JZ0 N FD R) z__ PRbPDSE-'IEMPOR R / C0 NSTTRUC11ON ASEMENTj r285 "-LIMIT5� DISTURBANCE/ ) + I OPOSED 16" DIP WATER LINE / 16 45' DI HORIZ. BEND - - CLEARING LIMITS (TYP.) / CID/i 3fA: 215+26 (WIDTH vg@lE5) _ — — C4/ / / 35"x10" LAUNCHING-P-1T -- — — — / � AS FI�2E NT \ / 16!"-45�DI HORIZ. BEND N/F `1 ..+� SfA: 218+96`�\ / --S I A: 21 5+1 2 VO NORiLR1C?rP.H''ARMACEUT CAS /� �- 3612 P9vvcy.TAN RD YrONNs.2Z527-0000 �� 0 • i GATE VALVE �\ B Nlk6 PG.020K __ / / f PLAN VIEW HORIZ: 1"=40' 294 292 290 288 286 284 282 280 278 276 274 272 270 268 266 264 262 260 I\ \ I I I I 31 q NEW FIRE YDRANT STA: 218+96 Al 3 f — r — 7ELE T OVER (TYP.) (D PTH APPROX.) (DEPTH APPROX. 1 I 1,0"x10" RECEIVIN ; PIT- x 1O- LAUNCHING i I � I . I ( CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) " I i PROPOSED 16* (DEP7H APPROX.)--- (DfPTH APP OX.) .__ --- 16 45' DI AORIZ. B ND I i I - STA: �` DI 215+ ORIZ. 2 CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) 16" GATE V LVE I I + JA K AND ORE 76 LF OF 0" STE CASING (THICKNESS 0.375") w/ 76 LF OF I 7HEORE CAL 214+00 REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING - NOT FOR CONSTRUCTION 0312]/20 C 90% DESIGN - NOT FOR CONSTRUCTION 21!1L120 B 60I DESIGN- NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/16/19 REVISIONS 215+00 216+00 217+00 218+00 PROFILE VIEW HORIZ: 1 "=40+ VERT. 1 "=4' v NI 10A&CREED v Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 219+00 220+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 221+00 294 292 290 288 286 284 282 280 278 276 274 272 270 r.; 266 264 262 260 221 +82 40' 0 40' 80' SCALE: 1"=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 213+90 - STA. 221+82 r NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT of UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ.START DATE: 2019.NOV MICE PROD. # 00358.0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP ►y R ►y 8' SCALE: 1"=4' (Vert.) SCALE C22 HORIZONTAL: 1"=40' DRAWING NUMBE VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:31:19 DAVID HAMMOND \ _ \ ------ WF \ / `' C co /R -w Rl' o �__. PP. NIF- 2367 GOOD BETTY L \ ,, ���lll \ \ - \ . " -'- YOUNG FAMILY IRREVOCABLE TRUST 2367 GORDON RD \ \ / _� / — — / \cU V \ `` 3739 NATIONAL DR STE 227 —'_.. �'•�� �— f — CLAYTON NO 27520-0000 —�� PIN: 7-1770 8:' Ij' VVV 00753 53 PG: PG:0045 GA VALVE STA: -222 01 — --278- 16" 5. I HORIZ. 15'�\ STA: 222+05 /ffi i i �4 � e i /FoIR GO � l i <1 292 290 288 286 284 282 280 278 276 274 272 270 268 266 264 262 260 258 257 19 24" R LIMITS OF -DISTURBANCE/ �- -Fol,) �\� _ ��� �� - CLEARING LIMITS (TYP.) _ WIDTH VARIES J — - �� 'NR �, �. -�tR) SIL�NCE_OUTLET (TYP.• . ( )-- � x1 EXIT IT _Fo(R1' � -::LQ R2- _ WHERE -SHOWN; SEE -DE AI -- r�j/ - ON R� �"111�OJJ SHEET �7 .. _ _ -- --- 2J2 38 1913 _� - - R) _ — SILT. FENCE (TYP. D ER, ;SHOWN SE L , (R)EC- ON -SHEET D7)if E v Fo R i ©\4 cro( - AI T r - -�'� -jKRj—. T(R)—.-22-7+00.=S�F_=�B\= _T INV-274.14 _-_r( R)-r228+00 -_ jam— 24E , 16 GATE VANE \ �- +• R) TlR) _ a STA25+O6 �_ Tg+00 �6"2\30' DI HORIS„ BEND STA:12 +03 — _ _ / \ \ �- T—''9�11 �23ot r r EAo wALL N (LOCATION APPROX.) 16" 11.25' DI VERT. BENT)' TEMP. SU R SILT. FENCE cv STA: 224+77 \\ (TYP. WHERE SHOWN. `SEEr(?3r0p-- U i J _— \ srRco LLJ DETAIL EC-11 ON SHEETI D7) PR POSED 16" DIP WATER LINE \ EAM 11 OB ��-.�--� '' ' . , WETLAND \ LL.1 - CROSSING \ 2 .. TEMP. WE D CRO I\ \ ,�' \ �, (TYP. WHERE SHOWN, SEE �1 PROPOSED PERMANENT \ \ A ` DETAIL EC-21 ON SHEET D8). \ _� 1TILITY EASEMENT N/F \ \ U �-t nnn N OVO�RDISK PHARMACEUTICAL r \� Z �— — \—_WLB-- _ 12 POWHATAN RD _ — 4 PIN 67700 57-1644 \ '.^—VIl9__ _� —WLB - —_ 28j WL9— = .5 -64 PLAN VIEW HORIZ: 1 "=40' - - _ N NI W I N N 01 WI I 121. -10 x COVER I S GATE A• 2224 M Lw Ot y — —E I — , " 45' DI HORIZ. BEND I 1 WAIW1 I (DEPTH APPROX.) 16" 11.25' 11 VERT. ENDSTA: I - 222+11 EX. WADE S VEY `- 16" GA VALVEIP W R LINE 16" 45 DI HOR Z. BEND + / 16" 22. 0' DI H RIZ. BED CONTRACTOR SHALL MAINTAIN CONSTANT UPWARD GRADE TO HYDRANT TO AVOID INTERMEDIATE HIGH POINTS (TYP.) STA: 2 5+03 10' MIN 16" 11. 5' DI VERT. BEN STA: 2 4+77 Ilk R-40 ' =400 PROPOS' M 222+00 223+00 224+00 225+00 226+00 227+00 PROFILE VIEW HORIZ: 1 "= 40' VERT: 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 03/27/20 C 90Y. DESIGN- NOT FOR CONSTRUCTION 03N3/20 B 60%DESIGN- NOT FOR CONSTRUCTION 01/07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11/16/19 REVISIONS .. I.C.... S l� W�049224 ; _ '., cP� •. fHG...... • G�� 0. v NigKM&QED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 228+00 229+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 230+00 292 290 288 286 284 282 280 278 276 274 272 270 268 266 264 262 260 258 257 231 +00 231 +31 40' 0 40' 80' SCALE: 1"=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL GORDON RD STA. 221+82 - STA. 231+31 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00368-0141 DRAWN DWH DESIGNED WOH CHECKED ASP PROJ. MGR. AJP 5 4' J 8' SCALE: 1"=4' (Vert.) SCALE C23 HORIZONTAL: 1"401 DRAWING NUMBE VERTICAL: D REVISION 'STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:32:04 DAVID HAMMOND 300 298 296 294 292 290 288 286 284 282 280 278 276 274 272 270 268 266 265 LIMITS OF DISTURBANCE/ CLEARING LIMITS (TV.) \ YOUNG FAMILVIRREVOCABLE TRUST (WIDTH VARIES) / / \ 3739 NATIONAL Dft S 27 RALEI GH NC, 275Y1-0013 \ \ /- PIN 167 IDS 7 -331 � 37+00 _ 16" 90' DI HORIZ. BEND STA: 237+78 -16" GATE VALVE STA: 237+96 -161 DI TEE STA: 238+01 -16" GATE VALVE STA: 238+07 J\ � \"NJ. t/ OMPOS+ SOCK (TYP. / /., \ : ` \ 11 .\ / 20"x16" DI REDUCER \\ WHER SHOWN SEE DETAIL y _ITQ 1 , / STA: 238+10 4y \ C-15 0 Sh1 T--D-7 // FDiR) _ LSA \ \\ J\ \ / �, o '-FG \tj\T \\ \ \ 16" GATE VALVE \\\ F K 28 j' l NEW FIR hFYDBLNT \ STA: 238+00 \ YOU RYIRREVOCA ETR ST - ® �� \ /'/ / \ �` \ \T j3 39NATIONAL DR STZ22] / ZIR�/ ASSEMB ALEIGH INC, 27612443 �. y / ; . / / i/ STA: 237+43 T \ \ \ \ `PIN:167700-46-3313� y Y B 04666." \ \\T \ \ \ 45- Dk HORIZ. BEND to PROPOSED 20" DIP WATER LINE \ \ \\_ :�'Yf1��/ % / \ ._: _ i �// ,r!00 i�`�l/ ✓-J�--•l, \ \ SSA. 237+52 ,. „ r \ \ \ \ \\ \ STRAW WATTLE (TYP. / 16 x16 DI TEE \ �\ KIRI' ss> \ STA 2 8+00 R• \� r\ \ WHERE SHOWN, SEE DETAIL ��O �t .' `• \ �� o \ \ \ EC-18 ON SHEET D8) 16'vf \ " GATE VE ) \ PROPOSED JEMAORARY `CTA: 238+ \ o \ \ \ CONSTRUCTION EASEMENT \ \ —� 16" 22.50' DI HORIZ. BEND\\� STA: 236+48 / / •`' .,I` 1' I \\ '` ��\\ `\ ?, DROP INLET �i- �C`I�N /NV.=290.83' PJ U1 W 'F 1/ De� R�\ R' r �� �f ; P OPOSED 16" DIP WATER LINE' / �4 WE N / / GOR '�"' '' ''-Y "CIRi �•S3k� - it •-\ Y CIHO �THEODORE; LIMES 1ti� \ "J•- �� 2 I / �R wF - / 2 FOX DEG g 4 \\ \ X i � Z CII{OS THEtGJ3OREJAMES \\ CLAYTON NC 2752 1 2017 F N I PIN: 1677 pL-r3C7 5 , ♦ " PP�p O N CLAYTO C 75 -0000 \ U i sy r/ PIN. 10700- 8 0 / DB: DB:011 PG. 06\ / l \/i/ /l \ \��, V TEMP. TREE PROTECTION r / +� vv v v FENCE TYP. WHERE SkIOWN, \ y ( \ o\� \\' \ G� <5;1 SEE DETAIL EC-10 GIN .�ET D7) 1 \ i)=MP. `Sl1PER SILT FENCE �, r, N/F \ , \� :TYP. WHERE SHOWN, SE CIHOS,THEODOREJAMES \ / R, ,�..x,TANSM/SyypggqION _ 2017 FOX / h ? DETAIL EC-11 ON SHEE1!) \ / CLAYTONNO27527� / /R / PIN: i16676700.37 \ . / ` \\ SILT NICE OUTLET TYP. r WHEREHOWN, SEE DETAIL EC=12 01 SHEET D7) PLAN VIEW HORIZ: 1 "=40' 40' 0 40' 80, SCALE: 1"=40' (Horiz.) I 0 y � Cil - NEW FIRE H RANT EMBL- 37+43 f1► �— \� - - — - AS STA: _ (DEPTH APPROX.) - (DEPTH -TELE- PPROX.) -- '', - —� TELAPA TEI E -APPROX. -- ---_---- - /—UNK EO- DEPTH A PROX. ---(DEPTH APF qOX) _ -- (DEPTI,I APPROX. -- 16" EPTH A DIP W PROX." - - - - ---- 24"MIN 10 Milli �- " COVER (T YP.) — - - - t 6„ 6„ D - - x 5' DI RED JCER - -- - 16" 22.5O DI H - ST RIZ. BEND : -236 16" 45- DI HORIZ. BED - 16" GA VALVE: I INF 16" 90' DI HORIZ. BED "xW - 16" Dl WATER, -'6 -- -- - _ STA: 2 DI TEE 8+01 _.. " - -- STA: 2 1E VA 7+96 232+00 233+00 234+00 235+00 236+00 237+00 PROFILE VIEW HORIZ: 1 "=40' VERT. 1 "=4' REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION OW27/20 C !0'/.DESIGN- NOT FOR CONSTRUCTION 03/13/20 B 0%DESIGN 6- NOT FOR CONSTRUCTION 02/07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11/16/1S REVISIONS 00 v M KM&CREED v Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 238+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 239+00 240+00 241 +00 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS 300 298 296 294 292 290 288 286 284 282 280 278 276 274 272 270 268 266 265 CIVIL GORDON RD & US HWY 70 STA. 231+31 - STA. 241 +22 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ.START DATE: 2019.NOV MICE PROJ. # 00350-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP a rel a K-0 SCALE: 1"=4' (Vert.) SCALE C24 HORIZONTAL: 1..=40' DRAWING NUMBE VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:32:57 DAVID HAMMOND 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 278 276 274 273 N N r- _----SS(R)---_— SS(R) SS(R)__.—_—SS(P)_—_.--SSR--_-- �(R)_—_--SS(R)_----SS(R)__---SSR—_--- SS(R).--.---SS(R)—.---- O SS(R)--__— ( ) SS(R)--_--SS(R)—__--SS(R)-----SS(R)-----SS(R)—".----SS(R)—.--__—SS(R)—_.--- SS(R)_---_.SS(R)----- STRAW WATTLE (TYP. WHERE SHOWN, SEE DETAIL EC-18 ON SHEET D8) STONE FILTER PIPE INLET PROTECTION (TYP. WHERE SHOWN, SEE DETAIL EC-16 ON SHEET D8) US HWY 70 BUS 20" 45' DI HORIZ. BEND STA: 245+75 LIMITS OF DISTURBANCE/ CLEARING LIMITS (TYP.) (WIDTH VARIES) US HWY 70 BUS INV.=295.13' N N� -.- -- �• 00 — - --- -- -- -� tTV 1�� -- - -- y----248+AQ---TV-- —z99 - -�+ ci ----=EQ--=�--2F h2Ei — — — -� =_ �r —_ — �_ --F -----p — _ p per— - - - - - — - - tea o_-_-_- - INV.-295.4 FO— —FO--- ~ L~ � —_ FpER}_.�__ _ — F _ _ _.—_ T _ _ 7 _ TV. O(R) —F _-FOB V) Lll — Z (n � � — FO-----FO— —_— --E --------g-- -----FO—---FOJ-----FO— �TL ----FO--- —T� _T----- �— — —Fa —CPp I PF f.L J W LLI-_ INV.=294.52" L 1 I I o PROPOSED PERMANENT 24T/+Od' U INV.=2s4.ss' UTILITY EASEMENT I� s �► z COMPOST SOCK (TYP. - : r , ; TEMP. SILT FENCE (TYP. \ ERE SHOWN SEE DETAIL WHERE SHOWN, SEE DETAIL - EC-15 ON SHEET D7) s .. Z > EC-08 ON SHEET D7) I 'PIROPOSED TEMPORARY 20" 45' DI HORIZ. BEND I I CONSTRUCTION EASEMENT \ \ \ STA: 246+47 I I N n ( SEE DETAIL EC'-06 ON \ \ \ 10"z10" RECEtVING.PIT I I 00 SHEET D7 FOR SILK' FENCE - \ N LAYOUT IN PIT LOCATIONS I 35"x10" LAUNCHING PIT P \29 8� JACK AND BORE 83 LF OF 36" STEEL g0� CASING (THICKNESS 0.50") w/ 83 LF OF-__ } - \ IRDNw000 DEVER€RsLI , „¢jF \ \ 442 1/2 EAST MAIN ST i \ 20" RJ DIP CARRIER PIPE LaLL (' \CLAYTON NC 27520 :7760J7EWE 13804726 PG:0573 533 - \ \ _ IRONWOOD DEVELOPERS, LLC ,,,•,t 9 \� \ OB:04" +" t 4421/2 EAST MAIN ST —^\ \ r \ PIN: NO, 25814 : \ \ PIN: 4726 PG 0573 DB:04726 PG:0573 ,, \ \ WE HORNS, W RILEY 226 BACKST�sT u + ¢¢55 PIN:16174PG:008 / 08:01174 PG:O808 TEMP. STRAW W/ NET LINER (TYP. WHERE SHOWN, SEE DETAIL EC-19 ON SHEET D8) 20" 45' DI HORIZ. BEND STA: 249+77� 20" 45' DI HORIZ. BEND STA: 249+43 20" 45' DI HORIZ. BEND STA: 247+80 __—TV-----TVA_— —_ 71� -- 248 -- �_C�—t�r—� PRO OSED PERMANENT U11LITY EASEMENT 20" �5- DI HORIZ. BEND STA:, 247+43 PLAN VIEW HORIZ: 1"=40' AIVJMn ,--I II ACE BLOCKING AAII EX. AS REQ'D I I • • • • u4�:ai`.!• »4.In LQ - '.� "10 0. II WE WELLONS ELMERJ I 31M GLENWOOD Ali I RALEIGH NC, 276125 07 ( PIN: 16T70D38.235� \ DB:04564 PG.0756 VA V 0 31 31 31 (D TH APPR X.) EP7H A ROX.) 0 5" PLASTIC GAS GRADE 0 0 EP7HAPPROX.) o I z v, � — FO f EPTH A ROX.) wool h LEC - i- i i (DE TH APPR X.) FO 2.5" PL S77C GA (Di PTH A PPf OX.) 12" PVC WL 1 1 I I I i 1 " DlP WL FO ' 35 10 LAUNCHING PIT GAS (MAT/DIA ?) I I i 10" STEEL GAS FO DX " 1 x10 RECEIVING PIT-`i I I I 1 MIN 1 " FM (M T?) - -- I 20" 45' DI HORIZ. BEND - I STA: 2474.80 I Ho in 20 45' DI IIORIZ. BEND STA: 249+,143 _i0_ff___456 DI HORIZ. BE D DI HO JACK AND BORE 83 LF C F 38" STEEL STA: 2 9+77 }PROF 20"45* ASING- THICK S-0.37 w SLOPE I 242+00 REV.NO. DESCRIPTION DATE D ISSUED FOR PERLIITnNG- NOT FOR CONSTRUCTION 03/27/HI C 90% DESIGN -NOT FOR CONSTRUCTION 03/13/20 B 80%DESIGN-NOT FOR CONSTRUCTION 02/0720 A 30%DES IGN- NOT FOR CONSTRUCTION 11/15/19 REVISIONS 10 243+00 244+00 245+00 246+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' v NFMM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC I-Imnse# F-1222 www.mckimcreed.com 247+00 248+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 249+00 250+00 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 278 276 274 273 250+60 40' 0 40' 80, SCALE: 1"=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL US HWY 70 STA. 241+22 - STA. 250+60 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 0 rel 5 -R 8' SCALE: 1"=4' (Vert.) SCALE C25 HORIZONTAL: 1^=40, DRAWING NUMBS VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:33:38 DAVID HAMMOND 312 310 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 278 277 ( �� — �• - .1 , '7 a-(a)m--- (a)m----- - —ap ' - - (a)m---(a)m- --(a) (aA-----(a)m-----(a)m----- �. _ -- _ - EX. SSMH -- �\ ���_� -_- ----ss(R)----- O - - — --%7129368•. _. ssR-----SS(R)----- O \r--(a)ss---.- ss R — — — ——sS(R)— — — — — (cisJ ��aj lcis) (a)ss _ - - sS(R)-----SS(R)----- y--(a)58----- \- (C/S) (a)SS-__--Q- -_.S7 �(R)-----SS(R)----- (a)ss--0--Ia)SS-----(a)ss-- _( (a)SS----- SS(R)- �(R)-----SS(R)-- y--SS(R)-----SS(R)-----SS(R)-----SS(R)---_— (R �----SS(R)---_—SS(R)—_---SSIR)—_---SS(R) US HWY 70 BUS EX. SSMH RIM=300.37' L�uo�20* NLET 1 /NV IN(E)=292.47' (8) LIMITS OF DISTURBANCE/ 5.80' 1 TEMP. STRAW W/ NET LINER I � «<� (TYP. WHERE SHOWN, 14 + SEE DETAIL EC-19 ON SHEET D8) to n LO LO US H I� N U INV.=299.72' WY 70 BUS EX. SSMH rc _G_-- RIM=306.42' �;.. .�0" 45' DI HORIZ. BEND - go __STA: 257, _lNV OUT(NE)=288.64' (8) 1 F- LLI 52f _ INV.=297.58"I HORIZ. BEND_ O® - - - -c 25 00STA: 254+48IDROP INLET I W 1Z � 1 /NV.=298.71' _ _ - -i - 1(� -CFO-----FO- .--.__. ru = in = F ----�- EU'- / STRUCTURE � FO -- "- - -- - 16" DIP r t UNK. SEWER INV.=299 09: t. w iri► 41 F� S ONE ElLT1=R PIPINLET 1 \�� 1 CLEARING LIMITS (TYP.) (WIDTH VARIES) 20" 450 DI HORIZ. BEND STA: 259+56 I' t 00 20" 450 DI HORIZ. BEND -F STA: 259+45 _ 1 r 0- 0 ` FO.----.-FO--.-.--F -- 0----- W-----W-- - �FE FJ]-= _ FO-L --T N N _- R- _gy p-- c - - ----FO---� O Z _ -FO --- w JN r GAS U a 1�ASPH AREAJ`, I DROP INLET \ I PROTECTIO (TYP. iMERE SHOWN, - e ° '"`DROP INLET NV.=299.6T SEE DETAIL EEC-16 °ON SHEET DO) = , I ARI�.�EN I I rx / INV.=299.30' STRAW WATTLE (TYP. B 0 TEMP. SILT CE TYP. WHERE SH� SEE DETAIL PROPOSED #PERMANENT ` 25 l0( WHERE SH SEEI DETAIL EC-18 ON SHEET D8 UTILITY EASEMENT Deo , EC-0 SHEET D7) - E �� I 20" 450 DI HORIZ. BEND ' ' / All STA: 255+46 �D ` �ar��9LR 20" ATE VALVE • ' LP WELLONS ELMERJ III /a ` Y AC 255+62 3126 GLENWOOD AVEAwlRALEIGH NC, 276125007 --'^ / T I 10"x10" ECEIVING PIT h PIN: ifi7700-38-2331 W' WELLONS, ELMER J IN r + DB:04569 PG. 0756 '�6' 1 I 3126GLENWOODAVE JACK: AND BOR 92 LF OF 36 STEEL ` I - E' 16770278-1597 CASING (THICKNE S 0.50") w/ 92 LF OF y� PIN: 161276-7597 D6:005fW PG:0756 2 " RJ DIP CARRIER PIPE, I� EX. MANHOLE BURIED. PRIOR TO CONSTRUCTION, L II CONTRACTOR TO LOCATE MANHOLE AND CONFIRM EX. I (s \ _ SANITARY SEWER LOCATION AND DEPTH. NOTIFY ENGINEER S \AND OWNER IMMEDIATELY SHOULD �CO FLICT OCCUR BETWEEN � PROPOSED WATER MAIN AND EX. ISIMTARY SEWER LINE. PLAN VIEW HORIZ: 1 "=40' ',ENT PROPOSED PERMANENT UTILITY EASEMENT r UTILITY EASEMENT PROPOSED TEMPORARY %T CONSTRUCTION EASEMENT I YARD INLET PROTECTION I (TYP. WHERE SHOWN, SEE DETAIL E o I SEE DETAIL EC-14 ON SHEET D7) SHEET D7 FO SILT EV IRONWOOD DEVELOPERS, LLC LAYOUT IN PI LOC ONS `� � 4427/2 EAST MAIN ST CLAYTON NC, 27520 ' I PIN: 167700-39-0281 N/F 08'.04726 1 Tft6liLC 25"xl0" LAU CH ING PIT ^' LONOM AD 2§ LONGMEADOW RO OR IL NC, 27856-3711 / . 0-36-0976 20�GAfiE VAL'ilE-' G:0917 STA: 256+75 20" 45' DI HORIZ. BEND` STA: 256+70 1 40' 0 40' 80' SCALE: 1"=40' (Horiz.) I I Q (DE TH APPR X.) o 0 0 � FO a v C91 EX. WADE (Gl) �^ FO (OE TH A x) 8 RCP FO f (DEPTH PPROX) " MIN 12" DIP WL DEPTH PPROX. (DEPTH APPROX.) CO R (TYP.) FO E 71~-2 "x10" kUNCHING PIT EC FO I I I I - - - 10"x 0" RECEIVING PI 16" DIP WL i i i R LINE 24 MIN �PIH A 18"MIN I ' ' ' ROPOSED 20" IP WA 1 2 " 45' D HORIZ. BEND TA: 25 +72 w 20" 0' DI H RIZ. BED STA: GATE VAINE 256+75 -SIT Al 254+ 20" 45' DI HORIZ. BEND STA: 256+70 STA: 255+46 (DEPTH APPROX. CASING (THI NESS 0 375" will 92 LF OF 20" ItJ DIP C RRIER PIPE 2 Om GATE VALVE- STA: 55+62 251+00 252+00 253+00 254+00 255+00 256+00 PROFILE VIEW HORIZ: 1"=40' VERT: 1"=4' REV.NO. DESCRIPTION DATE D j ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 23/27/20 C 90A DESIGN- NOT FOR CONSTRUCTION 03/73/10 B 0.6 6DESIGN- NOT FOR CONSTRUCTION OW07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11/16/19 REVISIONS 10 r q SE _ 049224 _ %,d'� �••. FiyGI NEE.• G��=` q�J7/1p 111 n00\ 3 )-'7- J` yJ g ICUED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC Lioal F-1222 www.mckimcreed.com 257+00 258+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 259+00 260+00 312 310 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 278 277 260+84 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL US HWY 70 STA. 250+60 - STA. 259+84 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROD. MGR. AJP 4' 6 6 8' SCALE: 1"=4' (Vert.) SCALE C26 HORIZONTAL: 1 "=40' DRAWING NUMBE VERTICAL: D REVISION TATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:34:21 DAVID HAMMOND I I R I Ta;l I (a)ss— — — ——(a)ss— — — — —(aXs— — — — — (a)SS— — — ——(a)SS— — — ——(a)ss— — — —(a)ss—(a)ss-----(ahs-----(a)ss-----(a)ss-----(a)ss-----(a)ss-----(a)ss-----(aXS-----(a)SS-----(a)ss—� ---(a)ss-----(a)ss-----(a)SS-----(ans-----(a)SS----- — — — — SS(R) — — — —SS(R)— — — — —SS(R)— — — ——SS(R)— — — ——SS(R)— — — ——SS(R)— — — ——SS(R)— — — ——SS(R)— — — ——SS(R)— — — ——SS(R)— — — — —SS(R)— — — — —SS(R) — — — — —SS(R)— �— — — —SSI —SS(R) — — — ——SS(R)— — — — —SS(R) — — — — — SS(R) — — — — —SS(R)— — — — —SS(R)— — — — — ss(R)— — — — —SS(R)— — — — —SS(R) — — — —— US HWY 70 BUS M 20" 45' DI VERT. BEND STA: 262+29 � NEW FIRE HYDRANT 20" 45' DI VERT. BEND US HWY 70 BUS ASSEMBLY 00 STA: 262+33 NV.=301.60' STA: 262+06 TEMP. STRAW W/ NET LINER (TYP. WHERE SHOWN, SEE DETAIL EC-19 ON SHEET D8) US HWY 70 BUS N LIMITS OF DISTURBANCE/ CLEARING LIMITS (TYP.) INV.=299.95' p+ (WIDTH VARIES) I� I _r INV=301.63 /NV.=300.96 p . _ I INV.=299.51 04 (O CO--T-----T-----T-----T----T--- —-----T--- — __ L--=—T—_--T-----T-- --T —_ T--- — —/ --- -----T-----T--I— —-----T-----T_—_--T--- —T---'__ ---T--- Ci _---Fp_—_——FO---_—pp_— —�0 ==FO_ -- 0_' NV 7 —I r.. — --]✓0 _ _----- -T-----T— T-----T——__T—__— T——T---n_��— T--_—__- �_—_---T---_ —5—= CEO-= —r —EO= — — p0 ----'—FTC--��y--ca --- �_�---F�O�-- — __ _ --F9 FO——Q U =�Y--- G =_— — G _— G FO--G- _F G— _ — .G__ — T T~�— --°__--T_----T— --- ~ lyf ..— — F�-_— — — — __— _— -F9-- _ _ _ _— Q —Fn T --F� =Fr —F .�'� — FO—�� _ .—�-- —=- -- -- — ——289tQ0�_ — --_G 9# --- N W ~ LU -261-+00.w W— ---w—� 0 — +QOw—---w--_ w—�---w--- —w�a 5�00 _----w-----w w--- P—w---Fr7+00 --- -- -- + -----w----r—w=--- — -- r (n W ¢-- V —FO V_ —�0 —FO— — —FOB—='--f —30—FO---_ --- ._ —F ®----FO— --� �O� c-- —ram-- — _ F --- — —--F0=F0—__ —i — _ _ — 0---= _FO_----FO-----Fp= <-- --- — T\.\, \ — — Z (!1 — --- _ o----- — — -- —F — -- --- -----F° ---- -- ---FP._ — -� --- — LS — J w F —_ F I E-----E---_—F--_--E-----E—--E--__—E' y1 ti ..._r \\ _ U LLJ 2i5„z6„ STA: 262+06 / —COMPOST SDK ETYP. / I\ �- E-DETAIL— I e PROPOSED PERMANENT II V / / I / EC-15 ON SHEET D7) -_ / I \ - J ,� � UTILITY EASEMENT TEMP. SILTFE CE"_ ` /r REPLACE BLOCKING AT EX. WHERE SHOWN, SEE DETAIL FHA AS REQ'D I r EC-08 ON SHEET D7) NIE _ /3p0 1 / \ \ V�LTHOM GROUP III LLC IINT WALTH 1/ GROUP III, LLC / _— -- \ / CLAYTON N0, 271200000 J ZZZLLL LA 112 E MANN STREET 4421/2 E MAIN ST t nyinN NC 27` 520-0000 .,-� PIN 167700-39 0749 / \\ .•- DB 03747 PG 0639 DB:D1933 PG:W7:0678 � - 1 -�' ,iS.r IRONWOOD DEVELOPERS LLC 314 312 310 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 / 442la EAST MAIN ST j( I CLAYTON NC, 27520PIN 167700-3�281 f \ DB:04726 PG:0678 PLAN VIEW HORIZ: 1 "=40' of ASSEMBLY 3 0 c1 TELE ----_ FO_— -- �� \ -- —;(DEPTH_Ar PROX.) 8' PVC WLP - (D PTH APP OX.) GA MAT/DlA ? (DEPTH A PROX.) -- FO FO — FO (DEPTH APPROX. FO 42" MIN 18 MIN 18 MIN w TA: 26 +29 — 20" 45' D VERT. END - -- TA: 26 +33 O P WATER LIN 261+00 262+00 263+00 264+00 265+00 266+00 PROFILE VIEW HORIZ: 1 "=40' VERT: 1 "=4' REV.NO. DESCRIPTION DATE D ISSUEDFOR PERMITTING- NOT FOR CONSTRUC11ON 03127/20 C 90%DESIGN- NOT FOR CONSTRUCTION 0311 U20 8 90%DESIGN - NOT FOR CONSTRUCTION 02/07/20 A 30% DESIGN -NOT FOR CONSTRUCTION 11/16H9 REVISIONS 11111111111// CARC SENL 049224 _ '.�dT�•'• FN6INEE`..••G����� 'VI I//III1111111\��\\ v 1 IMNIII&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 10 267+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 269+00 40' 0 40' 80' SCALE: 1"=40' (Horiz.) 314 312 310 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 270+00 270+26 JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL US HWY 70 STA. 260+84 - STA. 269+26 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP 4 711 0 Fin. SCALE: 1"=4' (Vert.) SCALE C27 HORIZONTAL: 1"=40' DRAWING NUMBER VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:35:06 DAVID HAMMOND 314 312 310 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 N/F C KLOPFER ASSOCIATES NC LLC J 0 1 MIIRAM R FL, 3302 -07 134 5 • -i. N .� i 3 AN - * h Pi 16799D-zoal4z v - i7 ,� / 7 F+ -{. DRW108 PG:0249 a„,•. r L '� r. LO (a)ss- - - --(a)SS- - - - - (a)ss-----(a)SsJ _ M ---- _--�-(a)ss-----(a)ss-----(a)ss-----(a)ss-----(ads---- (a)ss-----(ahs- W---(a)SS----- (a)SS-N .° Z u _----sS(R)--—SS(R)-----SS(R)-----SS(R)--�_-(a)SS 0 W US HWY 70 BUS I TEMP. STRAW W/ NET LINER co (TYP. WHERE SHOWN, 4 SEE DETAIL EC-19 ON SHEET D8) O N CV INV.=29 .32' U-T-----T-----T-----T-----T- -- T T F- LIJ 2 Z T, ` A�2 00 J W Fjo-0 -- -Fo s LIJ _ Vn INV.=298.22' STONE FILTER PIPE INLET PROTECTION (TYP. WHERE SHOWN, SEE DETAIL EC-16 ON SHEET D8) INV.=299.96 • Y INV.=297.39' INV.=298.45' COMPOST SOCK (TYP. WHERE SHOWN, SEE DETAIL EC-15 ON SHEET D7) STRAW WATTLE (TYP. WHERE SHOWN, SEE DETAIL EC-18 ON SHEET D8) 20" 45' DI VERT. BEND STA: 277+13 v- T-----T----T--- - _ _ - - _T_-- '�65 -T-----T-----T----"�---------- T---�----T-- `•� FO - - - _ -.—E2 aB - O- - -ZiS+OD,_/(--- - - -FM(R - - .-gRl_ _ I{� (R% FD - = Ell �7a ZiTO. EMHd1 -- y ---FIA - a--Z.S7R 1n139%�FM(41RL) F - ) ==F0- - `-FOW --- �O FO---- 1-----FO _ -_�ha _ _}- `S7 - -W-CFO --_ ' 1 ,yam fl(R) I o V.�,. IN=297.22�'S — 7'' 'rAi Lr. I \ a \\ GRIFOLS THERA Lr INC \ I DUZPO BOX 110 6 \ M NC, 2771 5$ 26 �IN: 167800.30-B071_.\ 421\0946 Fo •O, Fo- F�0"-G4� VE � FoSTA: 27 +10F -F=FO=F/N 9.56 R ~ - \ If y� \ R STA: 27 +03 END 20" 20" 45' DI *ORIZ.:,BEND I \ \ ` CONNEt; :"TO EX. WL STA: #72+ 9 d, TEMP. SILT F NCE (TYP. w/ 20"X20" CUT -IN DIP TEE -PROPOSED PEMA T ERE SHOWN, EE DETAIL LIMITS OF DISTURBANCE/\ S : 277+30 UTILITY'EASEM EC ON ET D7) CLEA ING LIMITS (TYP.) (WIDTH\ARIES) \ "ED PERMA4� EX. TOWN OF CLAYTO UTILIY ITY EASEMENT \ EASEMENT (LOCATION AP OX.) N/F GRIFOLS THERAPEUTIC INC .\ Q \ DURHAM NC; 955 PIN' 41-b181. 1 \ DB:04016 016 PPG 0366--'\ , 1 PLAN VIEW HORIZ: 1 "=40' ( EPTH APPROX.) g (DEP H APPROX.) ----- 16" DlP WL c91 - _ -- TE- _ (DEPTHAPPROEE) rE E T� (DEP H APPROX.)_-- 0 20" DI PLUG STA: 277+21 \r - --(a)ss- - - - -(a): 1-2" BLOW -OFF ASSEMBLY STA: 277+21 - _ OFoFSET_ -_T---- T--- -T--. --T- �i _FMSR)_-7=— _0---FO-- S--FO- I _.. ---FO---- F0— -Fp- I„-----FO- _ �- - c We —FO— FO---- ia)ng V- o 0 WL CONNE TO EX > " °I1 16 1a _�- STA: 277+30 42' IN 18"M , 2 X20 _. I TEE DEP,TN APPR � - - (DEPTH APPROX.) 0 A. 5' DI , VERT. END - - - - - - - - __ - -- - - -- -- - - --- - S A: 277 13 Eid -II -II - ----- -- - — — - - - I I '� 2 " GATE VALVE _- - OPOS D 20" DIP WA S A: 2774 10 _-- - STA.-973+ 20" 45' DI HORIZ. STA: 72+89-'i BEND - - REV.NO. DESCRIPTION DATE D ISSUED, FOR PERMITTING- NOT FOR CONSTRUCTION 03127/10 C 90%DESIGN-NOT FOR CONSTRUCTION 03I13120 B 60% DESIGN -NOT FOR CONSTRUCTION OX07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11115119 REVISIONS 271+00 272+00 273+00 274+00 PROFILE VIEW HORIZ: 1"=40' VERT: 1 "=4' v MfM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 10 275+00 276+00 JOHNSTON COUNTY DEPARTMENT OF UTILITIES 277+00 278+00 314 312 310 308 306 304 302 300 298 296 294 292 290 288 286 284 282 280 278+50 40' 0 40' 80' SCALE: 1"=40' (Horiz.) JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS CIVIL US HWY 70 STA. 270+26 - STA. 277+30 NOTES: 1. CONTRACTOR SHALL REMOVE AND REPLACE EXISTING CULVERTS WITH LIKE DIAMETER AND MATERIALS AS NEEDED FOR WATER MAIN CONSTRUCTION, WITH NO SEPERATE PAYMENT BEING MADE. NEW CULVERTS TO MATCH EXISTING GRADES. 2. NEW FIRE HYDRANTS SHALL BE PLACED INSIDE THE EXISTING RIGHTS -OF -WAY. HYDRANT SCALE SHOWN FOR CLARITY. 3. CONTRACTOR SHALL EXPOSE UTILITY CROSSINGS THROUGH VACUUM EXCAVATION OR HAND DIGGING WHEN WATER MAIN CONSTRUCTION IS WITHIN 200 FT OF UTILITY. 4. WATER MAIN SHALL BE INSTALLED WITH A MINIMUM OF 42 INCHES OF COVER UNDER EITHER THE EDGE OF PAVEMENT OF THE ADJACENT ROADWAYS OR EXISTING GRADE, WHICHEVER IS LOWER. PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED ASP PROJ. MGR. ASP I d 4 J 8' SCALE: 1"=4' (Vert.) SCALE C28 HORIZONTAL: 1 1'=40' DRAWING NUMBER VERTICAL: 1.1_4. D REVISION S TATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\CIVIL\C.01-003580141-J000385-SHEET&BASE.DWG 03/27/2020 10:35:49 DAVID HAMMOND PAVEMENT OR FINISHED GRADE GATE VALVE TO BE SAME SEE VALVE BOX INSTALLATION 4" MIN. DIAMETER AS MAIN LINE VALVE _ TAMPED BACKFILL III TAOMPED BACKFILL THREADED COUPLING - 2" THREADED BRASS OR —111_ DI PIPE D.I. PIPE , ;., CONCRETE BLOCKING MIN. 1/3 C.Y. AT 3000 P.S.I. "TYPE 304 STAINLESS STE I CONCRETETHRUST J THREADED RODS (MIN. 4 EA.) COLLAR 2" THREADED BRASS OR DI F MIN. MJ CAP W/ 2" TAP PIPE (12" IN LENGTH) PAY ITEM INCLUDES ALL ITEMS EXCEPT MAIN LINE VALVE TEMPORARY BLOW -OFF ASSEMBLY NOT TO SCALE JOHNSTON COUNTY WATER Department of Public Utilities STANDARD DETAIL P.O. Box 2263 vry Temporary Blow Off Smithfield, NC 27577 Assembly CONCRETE BLOCKING r EXIST. WATER MAIN ` 11 TAPPING SLEEVE TAPPING VALVE WITH VALVE BOX Uj NEW WATER MAIN TAPPING SLEEVE & VALVE ASSEMBLY NOT TO SCALE NOTES: 1. TAPPING SLEEVE SHALL BE FABRICATED OF TYPE 304 OR 316 S.S. AND PROVIDE A 3600 SEAL AROUND EXISTING PIPE WITH FULL CIRCUMFERENTIAL GASKET. 2. TAPPING SLEEVE SHALL BE JCM 432, MUELLER H-304, FORD FTSS, ROMAC ST III OR APPROVED EQUAL. 3. ALL MATERIALS USED IN THE POTABLE WATER SYSTEM MUST BE NSF61 AND NSF372 CERTIFIED AND MEET THE LATEST FEDERAL SAFE DRINKING WATER ACT REQUIREMENTS. DISTANCE AS NECESSARY TO SET BLOW -OFF IN AN AREA WHICH WILL ALLOW FOR POSITIVE DRAINAGE PAVEMENT OR FINISHED GRADE SEE VALVE BOX TAMPED BACKFILL INSTALLATION 4" MIN. 5/8" TYPE 304 STAINLESS STEEL VALVE THREADED RODS (MIN. 4 EA.) BOX D.I. PIPE THREADED COUPLING 2" BRASS NIPPLE OR D.I. CONCRETE BLOCKING 2" BRASS NIPPLE F'I MIN. 1/3 C.Y. AT 3000 P.S.I. CONCRETE THRUST OR D.I. COLLAR (MIN. 6" IN LENGTH) M.J. CAP W/ 2" THREADED TAP 5' MIN. 2" BRASS PIPE OR D.I. (MIN. 12- IN LENGTH) PAY ITEM INCLUDES ALL ITEMS PERMANENT BLOW -OFF ASSEMBLY NOT TO SCALE NOTES: 1) THE TOP OF THE BLOW -OFF STANDPIPE SHALL BE NO MORE THAN 4-6" BELOW GRADE. 2) BLOW -OFFS SHALL BE LOCATED IN AREAS WHICH WILL ALLOW FOR POSITIVE DRAINAGE WHEN UTILIZED. 3) ALL MATERIALS USED IN THE POTABLE WATER SYSTEM MUST BE NSF61 AND NSF372 CERTIFIED AND MEET THE LATEST FEDERAL SAFE DRINKING WATER ACT REQUIREMENTS. MIN. 10 LF DIP WATER MAIN CENTERED ON MANHOLE NOTES: 1. WATER MAIN SHALL BE DUCTILE IRON PIPE 10 LF CENTERED ACROSS MANHOLE. 2. CONTRACTOR TO INSTALL WATER MAIN AT DEPTH REQUIRED TO FACILITATE INSTALLATION OF AIR RELEASE MANHOLE AT HIGH POINT OF LINE. 3. ALL MATERIALS USED IN THE POTABLE WATER SYSTEM MUST BE NSF61 AND NSF372 CERTIFIED AND MEET THE LATEST FEDERAL SAFE DRINKING WATER ACT REQUIREMENTS. I,A_1�1 & DIA. PRECAST CONCRETE MANHOLE WITH FLAT TOP - —FINISHED GRADE 12" 5' MIN. - 24" MAX. TAPPING SADDLE S DIA. PRECAST CONCRETE MANHOLE WITH FLATTOP LOCKABLE 24" RING & COVER NCDOT TRAFFIC RATED W/ 1" DRILLED VENT HOLE USE STAINLESS STEEL HEXHEAD BOLTS FLUSH WITH FINISHED GRADE II111III11I MANHOLE STEPS SHALL BE PLACED 16" O.C. WHEN DEPTH OF MANHOLE EXCEEDS 5'. 2" AIR VACUUM/PRESSURE RELEASE VALVE (SHORT BODY) ARK D-025 OR APPROVED EQUAL 2" ISOLATION VALVE AND INLET PIPING SHALL BE SS 316 MIN. 12" #57 STONE SECTION STANDARD AIR RELEASE MANHOLE FOR WATER MAIN NOT TO SCALE Name Date !r-� Name Date r_ PAGE Drawn By: PAGE Drawn By: Checked By: JOHNSTON COUNTY STANDARD DETAIL WATER Checked By: JOHNSTON COUNTY 1 Approved By: Department of Public Utilities 2 Approved B : Department of Public Utilities Scale: P.O. Box 2263 mp Permanent Blow Off Scale: I P.O. Box 2263 asa Smithfield, NC 27577 Assembly I Smithfield, NC 27577 FASTEN BRIDLE RODS TO FITTING NOTES: 1. CARRIER PIPE SHALL BE D.I.P. UNLESS EXPRESSLY APPROVED BY THE COUNTY, 2. STAINLESS STEEL SPACERS SHALL BE USED. NO TIMBER SKIDS ARE ALLOWED. 3. TWO SPACERS PER JOINT SHALL BE USED FOR D.I.P. CARRIER PIPE. 4. THREE SPACERS PER JOINT SHALL BE USED FOR PVC CARRIER PIPE. 5. ENCASED BORES ALONG GRAVITY COLLECTION SYSTEMS SHALL NOT REQUIRE BRIDLE RODS. 6.2 EA. %4" S.S. BRIDLE RODS SHALL BE REQUIRED ON ALL LINES 8"0 AND SMALLER. 4 EA.'/4" S.S. BRIDLE RODS SHALL BE REQUIRED ON ALL LINES 10"0 AND LARGER. 7. CARRIER PIPE SHALL BE INSTALLED USING'FIELD LOK' GASKETS OR APPROVED EQUAL. 3/4" S.S. BRIDLE RODS SHALL BE WELDED TO THE ENCASEMENT PIPE. WELD AREAS SHALL BE PAINTED WITH 2 COATS OF BITUMINOUS BASE PAINT. PLAN 120 STAINLESS STEEL SPACERS ENCLOSE ENDS WITH BRICK MASONRY & GROUT STAINLESS STEEL SPACERS 120" CARRIER PIPE ILU STEEL ENCASEMENT PIPE SECTION CONFORMING TO ASTM SPECIFICATION A252-61 GRADE 2 AND A BITUMINOUS COATING ON THE OUTSIDE. STANDARD BORE ENCASEMENT NOT TO SCALE Name I Date �.r Name I Date I By WATER PAGE Drawn By: .ad BY JOHNSTON COUNTY Checked By: JOHNSTON COUNTY Vad By: Department of Public Utilities DETAILlities 5 Approved B Department of Public Utilities P.O. Box 2263 1� Tapping Sleeve and 5 Scale: P.O. Box 2263 msa Smithfield, NC 27577 Valve Assembly Smithfeld, NC 27577 Descri tion Date Init. Rev. Descri tion Date Init. .NO. DESCRIPTION DATE // ...C...... '' :Q�pFESS/0&*,..:9 AL 09224 !� (D) ; D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION ON27120 � `' - , � c 90%DESIGN - NOT FOR CONSTRUCTION OU13120 E.NGINEF-��.(••G�`\�` A 30%DESIGN- NOT FOR CONSTRUCTION 111O 16119 ///jIIIttH"``\\` REVISIONS 1T10 �L10 WATER STANDARD DETAIL Standard Bore Encasement THRUST COLLAR WATER STANDARD DETAIL Air Vacuum/Pressure Release Valve in Manhole NOTE: 1. MIN. OF 4 CU. FT. STONE (MORE IF REQ'D). 2. CONC. THRUST BLOCK TO HAVE MIN. OF 6 SQ. FT. BEARING ON SOLID BANK (MORE IF REQ'D.). 3. DRAIN HOLES AND FLANGES SHALL BE CLEAR OF CONC. 4. FIRE HYDRANT BARREL SHALL BE PLUMB. 5. ALL MATERIALS USED IN THE POTABLE WATER SYSTEM MUST BE NSF61 AND NSF372 CERTIFIED AND MEET THE LATEST FEDERAL SAFE DRINKING WATER ACT REQUIREMENTS. COAT HYDRANT BONNET AND NOZZLE CAPS W/ "ALERT' REFLECTIVE FIRE HYDRANT PAINT SILVER MODEL #1440 #67 STONE FILL 6-8" FINISHED GRADE BURY AS SPECIFIED CONCRETE THRUST BLOCK PUMPING & HOSE CONNECTIONS EQUAL TO COUNTY STANDARD BREAK RING TO BE SET WITHIN 2"-4" OF FINISHED GRADE VALVE BOX —I I I —_I I HYDRANTTEE IIII IT. SWATERLINE EE PLANS SIZE VARIES CONCRETETHRUSTBLOCK GATE VALVE VALVE SHALL BE PLACED ON THE #67 STONE FILL WATER MAIN SIDE OF ROAD DITCH (4 C.F. MIN.) PTHREADED RODS HYDRANT LEG TO DIP MIN. EA. PER SEGMENT OR PAY ITEM "Aqua -Grip" RINGS OR ROMAC FIRE HYDRANT ASSEMBLY INCLUDES GRIP RINGS MAY BE USED AT ALL ITEMS EXCEPT MAIN LINE TEE JOINTS IN LIEU OF THREADED RODS FIRE HYDRANT ASSEMBLY NOT TO SCALE "FIRE HYDRANTS INSTALLED ON EXISTING 6" WATER MAINS, MUST BE INSTALLED USING A 6"x6" TEE CUT INTO THE EXISTING WATER MAIN. FIRE HYDRANTS INSTALLED ON EXISTING WATER MAINS LARGER THAN 6", CAN BE INSTALLED USING A TAPPING SLEEVE AND VALVE ON THE EXISTING WATER MAIN. IVGIIIC VdLV PAGE Drawn By: Checked By: JOHNSTON COUNTY 3 A roved 8 : Department of Public Utilities SCBI1: P.O. Box 2263 ., .. Smithfield, NC 27577 CONCRETETHRUSTBLOCK AT 45' BEND. SEE THRUST BLOCK DETAIL FOR DIMENSIONS OF BLOCK. (BLOCKING IS ONLY REQUIRED IF THE BEND IS SET AT A HORIZONTAL ROTATION OF 22 DEG OR GREATER) I U IVIHII. NOTE: ALL PIPE SEGMENTS LESS THAN 10' SHALL REQUIRE RODDING. f S.S. THREADED RODS CRETE THRUST BLOCK 0' BEND. THRUST BLOCK DETAIL FOR DIMENSIONS OF BLOCK. ROD REQUIREMENTS SIZE OF 45" BEND STATIC THRUST IN POUNDS NUMBER OF RODS REQUIRED 6" 4,328 2 F. 7,694 2 12" 17,312 4 16" 30,779 6 20" 48,091 8 24" 69,252 10 GENERAL NOTES 1. RODS AND NUTS SHALL BE OF TYPE 304 OR TYPE 316 STAINLESS STEEL. 2. CONCRETE SHALL NOT CONTACT BOLTS OR ENDS OF MECHANICAL JOINT BENDS. 3. ALL BLOCKING WALL BE POURED, NO SAKRETE TYPE APPLICATION WILL BE ALLOWED. VERTICAL BEND RODDING AND BLOCKING DETAIL NOT TO SCALE rvame uace �r- PAGE Drawn By: Checked B : JOHNSTON COUNTY 6 A roved B : Department of Public Utilities Scale: I P.O. Box 2263 0P Smithfieltl, NC 27577 v 1VFM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC Uoense# F-1222 www.mckimcreed.com WATER PAGE STANDARD DETAIL 7 Critical Bend Rodding and Blocking Details JOHNSTON COUNTY DEPARTMENT OF UTILITIES NOTES: 1. CONCRETE SHALL BE 3,000 PSI MIN. 2. CONCRETE FOR THRUST BLOCKING SHALI BE KEPT FAIRLY DRY, THUS MAKING THE CONCRETE WEDGE SHAPE MORE EASILY FORMED WITH THE WIDEST PART (BLOCKING AREA) AGAINST UNDISTURBEI SOIL. 3. NO CONCRETE SHALL COVER ANY BOLTS OR GLANDS. 4. ALL FITTING AND ACCESSORIES TO BE WRAPPED WITH 10 MIL POLYETHYLENE PRIOR TO POURING BLOCKING. 5. VOLUME OF THRUST BLOCKING SHALL BE AS SHOWN ON THE THRUST BLOCKING SCHEDULE. SOIL (TYP.) PLAN BENDS r18"MIN. -10"0&LESS 1 24" MIN. - 12" 0 & GREAT- - WATER STANDARD DETAIL Fire Hydrant Assembly PLAN TEES SECTION X-X PLAN & ELEV. BENDS & TEES PLUGS PIPE 90' BENDB 45" BEND 22112' BEND 111/4° BEND TEE PLUG SIZE A A B A B A 1 B 1 A I B c D 4- 8" 12• 6" 8" 6' 6" 6" 6" B" 9' lu, i6" 6- 10' 12- a" 10" 11• 6" 6" 8' 10" lo- 12" 18" 8' 15' 13' 10' to- B' a" B" 8" 10" 12' 12' 24° lo' Is- 14' 10' 12- s' 10' 6" 10' 11" 14' 14" 25" 12' 20- 16' 12" 14- B' 12' a" 12' 14- is- 16' 30" 14' 22' 16' 14" Is- 111" 14' 10" 14- 16" 16' Is- 34" Is- 1 26' 1 20' Is- 19' 12" Is- 12" 18' 16" 20' 20" 36" 20' 36- 28' 24' 1B' t8" 13' 12" B" 19' 18' 24" 48' 24' 48' 33' 30' 21' 18" Is- 15" 11" 21' 21' 28" 56" THRUST BLOCK DETAIL NOT TO SCALE Name Date JOHNSTON COUNTY WATER Y: Department of Public Utilities STANDARD DETAIL P.O. Box 2263 Thrust Block Smithfield, NC 27577 5cri lion Date Init. JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS DETAILS JOHNSTON COUNTY STANDARD WATER DETAILS PAGE 4 PAGE 8 PROJ. START DATE: 2019.NOV SCALE MCE PROJ. # 00358-0141 DRAWN DWH HORIZONTAL: D 1 DESIGNED WOH 1"=40' DRAWING NUMBER CHECKED AJP VERTICAL: D PROD. MGR. AJP 1"=4' REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\DETAILS\CD.01-003580141-J000385-DETAILS.DWG 03/27/2020 10:35:51 DAVID HAMMOND 3' MIN. Drawn UNDISTURBED SOIL TRENCH WALL 4'-0" t L B CONCRETE THRUST COLLAR (3,000 P.S.I.) A �� I ANCHOR C 4 D.I.P. RING I MAIN e4 SECTION NOTE: 6" TO 16" MAINS = 12-NO. 7 BARS 20" TO 36" MAINS = 12-NO. 8 BARS BARS PLACED AS SHOWN CONCRETETHRUST _COLLAR (3,000 P.S.I.) I III I I �— —III I I I=1 I I=1 11= .�y.< ANCHOR . I I a D.I.P. TRENCH WALL RING - - MAIN " � TAMPED BACKFILL PLAN UNDISTURBED SOIL SCHEDULE PIPE DIAMETER CONCRETE THRUST COLLAR ANCHOR COLLAR RINGS REQUIRED A B C 6",8°,12' V-0" 1'-0" 2" ONE 16" 1'-4" 1'-0" 2" ONE 20" 1'-4" 1-0" 3" ONE 24" V-4" 1'-0" 3" TWO 30" 1'4" V-2" 4" TWO 36' 1'4" V-4" 4" TWO THRUST COLLAR INSTALLATION NOT TO SCALE uace JOHNSTON COUNTY WATER Department of Public Utilities STANDARD DETAIL P.O. Box 2263 RtIF Thrust Collar Smithfield, NC 27577 Installation Date Init. FOR USE IN PAVED AREAS FOR USE IN UNPAVED AREAS VALVE BOX COVER FINISHED PAVED AREA 1 11�7� 111 N. 2 �{L/ FINISHED GRADE + F IN UNPAVED AREA BASE COURSE_ - _ -#__ 61, A q I ^ I : I V I I V/y - _-_I_ CONCRETE _ _ _ _ PROTECTOR TAMPED BACKFILL J - -_-_ -_- RING _-_- -_ - - VALVE BOX TAMPED BACKFILL WATER MAIN - - -- _-_- VALVE TAMPED BACKFILL � BLOCKING NOTES: 1. D.I.P. MAY BE USED FOR VALVE BOX EXTENSIONS. 2. VALVE BOX SHOULD NOT CONTACT WATER MAIN OR VALVE. 3. CONCRETE PROTECTOR RING SHALL BE USED IN ALL UNPAVED AREAS. 4. ALL MATERIALS USED IN THE POTABLE WATER SYSTEM MUST BE NSF61 AND NSF372 CERTIFIED AND MEET THE LATEST FEDERAL SAFE DRINKING WATER ACT REQUIREMENTS. VALVE AND VALVE BOX INSTALLATION NOT TO SCALE JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 �!P Smithfield, NC 27577 DESCRIPTION WATER STANDARD DETAIL Valve and Valve Box Installation RESTRAINED FLANGE ADAPTER "UNIFLANGE" OR EQUAL MJ ACCESSORY KIT DIP (BELL) III DIP (PE) 3/4" THREADED TYPE 304 OR TYPE 316 S.S. RODS MIN. 4 EA. "FIELD LOK" GASKET OR EQUAL HARNESS RESTRAINT DETAIL NOT TO SCALE Name Date PAGE Drawn By: Checked By: JOHNSTON COUNTY 9 A roved By: Department of Public Utilities Soale: P.O. Box 2263 1elP Smithfield, NC 27577 PAGE 13 DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 03127/20 C 901, DESIGN- NOT FOR CONSTRUCTION 03/13/20 9 e0%DESIGN- NOT FOR CONSTRUCTION 02/07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11/16/14 #3 REBAR 10" 2 EA. 2" el 24" PROPOSED WATER MAIN UIY 12" MIN. (24" MIN. IN NCTOD ROW) Y4" S.S. THREADED UROJDS THRUST COLLAR 45°BEND —� tea— 45°BEND CONCRETE B10LOCKING FUSED PIPE PE 10' FUSED PIPE THRUST COLLAR (n'P) 1 EA. JOINT OF DUCTILE IRON OR HOPE FUSED PIPE PIPE CENTERED UNDER STORM DRAIN. PIPE SHALL BE BEDDED BACKFILLED TO 6" ABOVE PIPE IN WASHED STONE. STORM DRAIN PIPE CROSSING DETAIL NOT TO SCALE NOTES: 1. CULVERT CROSSINGS IN EXISTING NCDOT RIGHT-OF-WAY REQUIRE 24" MIN. SEPARATION FROM BOTTOM OF CULVERT TO TOP OF WATER MAIN. 2. IN LIEU OF RESTRAINT (TIE) RODS, APPROVED RESTAINT JOINT PIPE MAY BE USED. rvame uace PAGE Drawn By: WATER Checked By: JOHNSTON COUNTY STANDARD DETAIL 10 Approved By: Department of Public Utilities Restraint Harness Scale: P.O. Box 2263 esa Smithfield, NC 27577 o..., n....-.:..•:..., n...,, ten NOTE: PROTECTOR RING SHALL BE 3,000 P.S.I. CONCRETE. CONCRETE PROTECTOR RING NOT TO SCALE JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 qbP Smithfield, NC 27577 �.,`RjN t CAROB' /,,� ✓ SEAL 049224 _ :C0 WATER STANDARD DETAIL Concrete Protector Ring NOTE: WATER LINE SHALL BE DUCTILE IRON PIPE AT ALL AREAS WHERE MIN 12" CLEARANCE CANNOT BE MAINTAINED. INSTALL AT LEAST ONE JOINT CENTERED OVER STORM DRAIN. DW) -yI STORM PIPE O.D. + 3' PROPOSED WATER MAIN EXISTING STORM PIPE 1 EA. JOINT OF DUCTILE IRON PIPE CENTERED UNDER STORM DRAIN IF TOP OF PIPE IS WITHIN 3 FEET OF BOTTOM OF STORM PIPE. 12" MIN. (24" IN NCDOT ROW) CLEARANCE NO. 57 WASHED STONE 10' MIN D.I.P. OR 10' MIN D.I.P. OR _ HOPE FUSED PIPE HDPE FUSED PIPE STORM SEWER CROSSING DETAILS NOT TO SCALE WATER STANDARD DETAIL Storm Pipe Crossing PAGE 1 1 Name Date JOHNSTON COUNTY Department of Public Utilities P.O. Box 2263 Asa Smithfield, NC 27577 STANDARD WATER DETAIL Storm Sewer Crossing PAGE 1 Drawn By: Checked B : A roved B : Scale: MJxMJ OR MJ SLEEVE W/ FLANGE x FLANGE MEGA -LUG GLANDS i 5„ CONNECTION NOTES: 1. VALVE MARKERS SHALL BE PLACED AT RAN. 1I ,�� °rl All wwo 2. LETTERS"MW SHALL FACE CAST IN CONC. TOWARDS VALVE. 3. MARKER SHALL HAVE BRASS 6"1®enuu AfEA.S PAINTED BLACK HDPE DIP DIP DIP PVC OR BRONZE EMBED ON TOP FINISHED GRADE OR SIDE. _ 31_ 611 - _I 4. CONTRACTOR SHALL STAMP I —I 4 EA. - #3 REBAR DISTANCE TO CENTER OF (1 EA. CORNER) VALVE INTO EMBED. 5. BLOW -OFF ASSEMBLY SHALL INCLUDE 1 EA. MARKER W/ SQUARE MARKER FIELD-LOK "BO" OR "MV" CAST. WITH BEVELED CORNERS GASKET VALVE MARKER DETAIL NOT TO SCALE IVGIIIC VGIC Drawn By: PAGE Checked By: JOHNSTON COUNTY 14 A roved By: Department of Public Utilities Scale: P.O. Box 2263 SIP Smithfield, NC 27577 v ��&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com WATER STANDARD DETAIL Valve Marker JOHNSTON COUNTY DEPARTMENT OF UTILITIES HDPE PIPE CONNECTION NOT TO SCALE rvame uace PAGE Drawn By: Checked By: JOHNSTON COUNTY WATER 15 A proved By: Department of Public Utilities STANDARD DETAIL Scale: P.O. Box 2263 �T HDPE PIPE CONNECTION Smithfield, NC 27577 Rev. Description Date Init. JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS DETAILS JOHNSTON COUNTY STANDARD WATER DETAILS PAGE 16 PROD. START DATE: 2019.NOV SCALE HORIZONTAL: 1"=40' VERTICAL: 1"=4' ^ DL L DRAWING NUM MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP D REVISION PROJ. MGR. AJP 'STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\DETAILS\CD.01-003580141-J000385-DETAILS.DWG 03/27/2020 10:35:55 DAVID HAMMOND NOTE: PIPE SHALL BE BEDDED UP TO SPRING LINE AND MINIMUM 4" BELOW BOTTOM OF PIPE WHEN WET AREAS ARE ENCOUNTERED. HAND PLACED DENSELY COMPACTED BACKFILL TO 1 FT. ABOVE TOP OF PIPE — — — — — - — -— I— — — — -- UNDISTURBED EARTH — —_— — — ELECTRONIC MARKER BALLS AT 100' ON —.PIPE -- CENTER & AT BENDS. MARKER BALLS SHALL BEDDED PIPE _— O.D. - —_ BE INSTALLED AT 1 1/2 TO 2' DEEP. NOTE: MARKER BALLS SHALL BE INSTALLED _— — CONCURRENTLY WITH PIPE. MARKER SHAPED SUBGRADE — I'_ BALLS SHALL NOT BE INSTALLED AFTER SHALL PROVIDE BEARING - ( TRENCH HAS BEEN COMPLETELY ALONG ENTIRE LENGTH III BACKFILLED. OF PIPE BARREL 112 PIPE O.D. 24" + O.D. MAX. NOTE: WATER MAINS 8"0 AND SMALLER SHALL HAVE MINIMUM OF T COVER. WATER MAINS LARGER THAN 8"0 SHALL HAVE A MINIMUM OF T-6" COVER. PIPE LAYING CONDITION NOT TO SCALE FINISHED GRADE I it METER (US GAL.) V X Yq 8"-10" MIN. LOCK TYPE 20" MIN. METER STOP CL 7" SERVICE LINE TO HOME METER YOKE SHALL BE MUELLER NO. H-1404-2, FORD NO. VH-72-7W OR APPROVED EQUAL FOR '3Y," SERVICE LID SHALL BE LABELED "WATER METER" AND SHALL BE "AMR" TYPE WITH METAL FLIP -UP LID AND 2" HOLE MIN. 4" WASHED STONE ANGLE DUAL CHECK VALVE BLOCK SUPPORT OR STONE AS NEEDED 2'-4" TYP (CAN NOT EXTEND MORE MOTH SIDE THAN 1" INTO BOX) %" OR 1" CLASS 200 ' POLYETHYLENE WATER ,. SERVICE LINE • WIDE BODY OR DOUBLE STRAP SADDLE I COPPERSETTER METER YOKE COMPLETE WITH 300 PSI DUAL PURPOSE FITTINGS CORP. STOP WATER MAIN — NOTE: 1. CONTRACTOR SHALL PLACE METER BOX IN NON TRAFFIC AREA ONLY, OUTSIDE FENCED AREAS, AND 4 FEET AWAY FROM BUSHES AND TREES THAT COULD COVER THE BOX. 2. PLASTIC METER BOX SHALL BE CENTURY #1015, NDS D1200, OR APPROVED EQUAL 3. CONTRACTOR SHALL CENTER METER YOKE IN METER BOX. 4. METER YOKE TO MUELLER No. H-1404-2A, FORD No. VHH-72-7W-11 OR APPROVED EQUAL. 5. METER TO MEET AW WA C-000 STDS. AND SPECS. 6. METER TO BE PROVIDED AND SET BY JOHNSTON COUNTY. METER WILL NOT BE INSTALLED IF, THE THE SETTER IS NOT CENTERED IN THE BOX, THE SETTER HAS BEEN PULLED UP ON ONE END, THE SETTER IS LAYING ON ITS SIDE, THE SETTER IS TO CLOSE TO THE BOX LID, THE BOX IS BELOW GRADE OR BROKEN, THE CUSTOMERS SERVICE LINE IS NOT HOOKED TO THE UNION NUT, THE 3/4 GATE VALVE HAS NOT BEEN INSTALLED WITHIN 12 INCHES OF THE METER BOX. 7. ALL MATERIALS USED IN THE POTABLE WATER SYSTEM MUST BE NSF61 AND NSF372 CERTIFIED AND MEET THE LATEST FEDERAL SAFE DRINKING WATER ACT REQUIREMENTS. 8. SERVICE LINE TO HOME MUST PASS PLUMBING INSPECTION PRIOR TO SETTING METER. NOTES: 1. TAP ON THE MAIN SHALL BE MADE IN THE POSITION SHOWN. 2. LOCATE METER BOX AS SHOWN ON PLAN NOTE: OR AS DIRECTED IN THE FIELD. 1. ALL TAPS 2" AND SMALLER SHALL BE MADE WITH TAPPING SADDLE. 3. PIPE FROM MAIN TO METER STOP TO BE ALL TAPS LARGER THAN 2" SHALL BE MADE WITH TAPPING SLEEVE LEVEL OR CONTINUOUS UP GRADE. AND VALVE. NO DIRECT TAPS SHALL BE MADE. 4. TOP OF BOX TO BE AT LEAST 10" BELOW 2. ALL MATERIALS USED IN THE POTABLE WATER SYSTEM MUST ELEVATION OF ADJACENT EDGE OF BE NSF61 AND NSF372 CERTIFIED AND MEET THE LATEST PAVEMENT WHEN SET IN ROAD/STREET T OF 1" WIRE REINFORCED FEDERAL SAFE DRINKING WATER ACT REQUIREMENTS. SHOULDER. EXACT LOCATION OF BOX RUBBER HOSE COILED IN BOX TO BE DETERMINED IN FIELD. SET FLUSH WITH FINISH GRADE WHERE NO PAVEMENT EXIST. METER BOX —7 FINISHED GRADE —r LOCKABLE V METER STOP 1" CLASS 200 POLYETHYLENE SERVICE PIPE, LENGTH AS REQUIRED 1" CORPORATION STOP AND MIP x COMPRESSION FITTING I TAPPING SADDLE WATER MAIN MIP x NIPPLE TAPPING SADDLE SHALL BE BRASS OR BRONZE FOR "CC" THREADS WITH DOUBLE STRAPS, FORD S-90, MUELLER BR2B OR APPROVED EQUAL. TAPPING SLEEVE SHALL BE BRASS OR BRONZE FOR "CC" THREADS, FORD S-70, MUELLER H-134, JCM 403 OR APPROVED EQUAL FOR SDR-21 PVC. J I S.S. HOSE CLAMP CLASS 200 POLYETHYLENE COMPRESSION TYPE CONNECTOR 1" CLASS 200 POLYETHYLENE ft CORPORATION STOP SHALL B SERVICE PIPE BRONZE WITH "CC" THREADS AND RATED 300 PSI, MUELLER B-25008, FORD FB-1000-NL, OR APPROVED EQUAL MANUAL AIR RELIEF VALVE ASSEMBLY NOT TO SCALE DUCTILE IRON PIPE P.V.C. PIPE (CLASS 50 CEMENT LINED) (CLASS 200) NOTE: ALL TAPS TO BE MADE ON TOP QUARTER OF MAIN. STANDARD WATER TAP DETAIL NOT TO SCALE 3/4" & 1" WATER METER SERVICE DETAIL NOT TO SCALE Name Date Name Date Name Date Name Date Drawn By: PAGE Drawn By: PAGE Drawn By: PAGE Drawn By: PAGE WATER WATER WATER Checked By: JOHNSTON COUNTY Checked B : JOHNSTON COUNTY Checked By: JOHNSTON COUNTY Checked By: JOHNSTON COUNTY WATER Approved By: STANDARD DETAIL Approved B : STANDARD DETAIL STANDARD DETAIL Department of Public Utilities0* Department of Public Utilities 3 �� Approved Department of Public Utilities 25 Approved By: Department of Public Utilities STANDARD DETAIL 20 Scale: P.O. Box 2263 Pipe Laying 17 Scale: P.O. Box 2263 �p /4' and 1" Scale: P.O. Box 2263 *x,-D Manual Air Relief Scale: P.o. Box 2263 �a Standard Water Tap Smithfield, NC 27577 Condition Smithfeld, NC 27577 Water Meter Service Smithfield, NC 27577 Valve Assembly Smithfield, NC 27577o.,,, n.......:........ n.,.,, L.:. ondm�n�ra Ina a>„ noo�d�N�o nom hIr Ram na���lofho nnm Ina DESIGN PARAMETERS DEPTH OF BURY: 3.5 FT SAFETY FACTOR: 2:1 TRENCH TYPE: 3 (PIPE BEDDING IN 4" LOOSE SOIL. BACKFILL LIGHTLY CONSOLIDATED TO TOP OF PIPE) TEST PRESSURE: 200 PSI SOIL TYPE: (CL,CH,SC,SM) TOPSOIL, INORGANIC CLAYS OF LOW, MODERATE, & HIGH PLASTICITY. SILTY & CLAYEY SAND. BACK FILLED USING NATIVE SOILS. NOTE: 1. THE CONTRACTOR SHALL INSTALL RESTRAINED JOINT THRUST PROTECTION AT ALL BENDS, TEES, WYES, REDUCERS, VERTICAL OFFSETS, VALVES AND PLUGS. THE LENGTHS SHOWN BELOW ARE TYPICAL LENGTHS REQUIRED FOR THE DESIGN PARAMETERS SHOWN ABOVE. THESE RESTRAINING CONDITIONS ARE COMMON CONDITIONS ENCOUNTERED IN NORMAL PIPELINE CONSTRUCTION, ANY OTHER CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER. 2. WHEN USING MECHANICAL JOINT RESTRAINTS SUCH AS MEGA -LUGS FOR PVC & DIP OR TR FLEX AND GRIFFIN SNAP-LOK, CONCRETE BLOCKING IS EXCLUDED FROM THE INSTALLATION. 3. THE RESTRAINED LENGTHS PROVIDED IN THE TABLE BELOW ARE MEASURED IN FEET AND SHALL BE APPLIED TO EACH SIDE OF THE SPECIFIED FITTING AS SHOWN IN THE DETAIL. MC-1 MECHANICAL JOINT RESTRAINT DETAILS REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION ON27120 C 90"/"DESIGN- NOT FOR CONSTRUCTION 03/73/20 B 60% DESIGN -NOT FOR CONSTRUCTION 07/07/20 A 30% DESIGN -NOT FOR CONSTRUCTION 11/16/19 REVISIONS �L� TAPPING SLEEVES VALVES & & TEES DEAD ENDS I�L-> - UPPER BEND i CARC 049224 �'.,id1� •. FhGINEER.•'G,z� ////0. Irk f llllllll\\\\ rj J L L J CROSS ! LOWER BEND VERTICAL OFFSETS �IL REDUCERS L� HORIZONTAL BENDS v NfWM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com MINIMUM RESTRAINED PIPE LENGTHS (LINEAR FEET) TABLE Main Pipe Diameter (inches) Horizontal Bends (Degrees) Tap. Sleeves, Tees, 8: Wyes Reducers (Main Diameter x Reducer Diameter (inches) Valves & Dead Ends Vertical Offsets (All Bend Angles) 90 45 22.5 11.3 x6 x8 x10 x12 Upper Lower 24 140 58 28 14 10 305 289 268 243 329 137 33 20 121 50 24 12 10 253 233 208 177 282 117 28 18 111 46 23 11 10 226 202 174 140 258 107 26 16 101 42 21 10 10 196 170 138 99 233 97 23 12 80 33 16 8 10 132 96 53 181 75 18 10 68 29 14 7 10 95 52 154 64 15 8 57 24 12 6 10 54 128 53 13 6 44 19 9 5 10 98 41 10 4 32 13 7 4 10 70 29 7 3 27 11 6 3 10 58 24 6 JOHNSTON COUNTY DEPARTMENT OF UTILITIES N.T.S. JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS DETAILS JOHNSTON COUNTY STANDARD WATER DETAILS PROJ. START DATE: 2019.NOV MCE PROJ. # 00358.0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP SCALE D3 HORIZONTAL: 1"=40' DRAWING NOW VERTICAL: D REVISION TATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80—DRAWINGS\DETAILS\CD.01-003580141—J000385—DETAILS.DWG 03/27/2020 10:35:58 DAVID HAMMOND SAWCUT PRIOR TO 1 EXCAVATION PAVEMENT SHALL BE CUT TO PROVIDE A CLEAN EDGE C"•) JOINT SEAL k TACK COAT ASPHALT PAVED ROADS (NON —STATE ROADS) UNPAVED ROADS PRIVATE CONCRETE DRIVE PRIVATE ASPHALT PAVED DRIVE MATCH A. AREA TO BE TAMPED. B. 6" OF CRUSHED STONE C. 2" BITUMINOUS CONCRETE SURFACE COURSE TYP S9.5A. D. 8" CRUSHED STONE. E. NEW CONCRETE J" THICKER THAN EXISTING CONCRETE, BUT NO CASE LESS THAN 6 INCHES THINK. NOTES: 1. PAVEMENT ON NON —STATE ROADS SHALL BE REPAIRED WITHIN A MAXIMUM OF THREE (3) DAYS FROM THE DATE THE CUT WAS MADE. 2. OPEN CUT OF NCDOT ROADWAYS WILL NOT BE ALLOWED WITHOUT PRIOR APPROVAL FROM THE NCDOT DISTRICT ENGINEER. 3. WIDTH OF CONCRETE DRIVEWAY RECONSTRUCTION SHALL NOT EXCEED 5 FEET EXCEPT FOR THE FOLLOWING CONDITION: 3.1. IF NEAREST EXPANSION JOINT IS 2 FEET OR LESS FROM THE LIMITS OF RECONSTRUCTION, THE CONTRACTOR SHALL REMOVE AND RECONSTRUCT DRIVEWAYS TO THE NEAREST EXPANSION JOINT ON EITHER SIDE OF THE RECONSTRUCTED CONCRETE. INSTALL NEW EXPANSION JOINT MATERIAL. MC-21 PAVEMENT REPAIRS FOR TOWN ROADS REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 03/27120 C 90%DESIGN-NOT FOR CONSTRUCTION 03113120 B 60%DESIGN- NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11/16119 REVISIONS N.T.S. CARo Q � 049224 %�cP�'•. FNGINEE�•••G����� CUT TO NEAT EDGE 12" -. _ - _ -' 12" 6" HB BINDER BURIED PIPE LINE SELECTED BACKFILL TAMPED IN LAYERS �— — — PAVEMENT REPAIRS FOR NCDOT ROAD OPEN CUTS NOT TO SCALE Name Date Drawn By: WATER PAGE Checked By: JOHNSTON COUNTY STANDARD DETAIL .� A roved B Department or Public Utilities Scale: P.O. Box 2263 Cutting and Replacing Smithfield, NC 27577 Pavement Rev I DpRoption I Date Tit v NFKMI&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com JOHNSTON COUNTY DEPARTMENT OF UTILITIES JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS DETAILS PAVEMENT REPAIR & MISC DETAILS PROD. START DATE: 2019.NOV MCE PROJ. # 00356-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP SCALE I D4 HORIZONTAL: 1"=40' VERTICAL: 1"=4' DRAWING NUMBER D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTIONFOR CONSTRUCTION 1:\00358\0141\WATER\80—DRAWINGS\DETAILS\CD.01-003580141—J000385—DETAILS.DWG 03/27/2020 10:36:00 DAVID HAMMOND GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCGO1 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. Required Ground Stabilization T[meframes Stabilize within this Site Area Description many calendar Timeframe variations days after ceasing land disturbance a Perimeter dikes swales ditches and 7 None perimeter slopes (b) High Quality Water 7 None (HQW)Zones (c) Slopes steeper than If slopes are 10' or less in length and are 3:1 7 not steeper than 2:1,14 days are allowed -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, (d) Slopes 3:1 to 4:1 14 ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed -7 days for perimeter dikes, swales, (e) Areas with slopes ditches, perimeter slopes and HQW Zones flatter than 4:1 14 -10 days for Falls Lake Watershed unless there is zero slope Note: After the permanent cessation of construction activities an areas with temporary P Y P ry ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: • ryg Tem ora Toss seed covered with straw or P other mulches and tackifiers • Hydroseeding • Rolled erosion control products with or without temporary grass seed is Appropriately applied straw or other mulch • Plastic sheeting Permanent Stabilization • Permanent grass seed covered with straw or other mulches and tackiffers • Geotextile fabrics such as permanent soil reinforcement matting • Hydroseeding • Shrubs or other permanent plantings covered with mulch • Uniform and evenly distributed ground cover sufficient to restrain erosion • Structural methods such as concrete, asphalt or retaining walls • Rolled erosion control products with grass seed 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite. 5. Store flocculants in leak -proof containers that are kept under storm -resistant cover or surrounded by secondary containment structures. EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids store in separate containers and properly dispose as P P P P Y p hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers e. dum ster trash (g P receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8. Dispose waste off -site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at [east 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. q 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide stakingor anchoring of portable toilets during periods of high winds or in high g P gP g g foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. CONCRETE WASHOUTS spills or overflow. 1. Do not discharge concrete or cement slurry from the site. 7. Locate washouts in an easily accessible area, on level ground and 2. Dispose of, or recycle settled, hardened concrete residue in install a stone entrance pad in front of the washout. Additional accordance with local and state solid waste regulations and at an controls may be required by the approving authority. approved facility. 8. Install at least one sign directing concrete trucks to the washout 3. Manage washout from mortar mixers in accordance with the within the project limits. Post signage on the washout itself to above item and in addition place the mixer and associated identify this location. materials on impervious barrier and within lot perimeter silt fence. 9. Remove leavings from the washout when at approximately 75% 4. Install temporary concrete washouts per local requirements, capacity to limit overflow events. Replace the tarp, sand bags or where applicable. If an alternate method or product is to be used, other temporary structural components when no longer contact your approval authority for review and approval. If local functional. When utilizing alternative or proprietary products, standard details are not available, use one of the two types of follow manufacturer's instructions. temporary concrete washouts provided on this detail. 10. At the completion of the concrete work, remove remaining 5. Do not use concrete washouts for dewatering or storing defective leavings and dispose of in an approved disposal facility. Fill pit, if curb or sidewalk sections. Stormwater accumulated within the applicable, and stabilize any disturbance caused by removal of washout may not be pumped into or discharged to the storm drain washout. system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER rA 1 1 1 is 1 1 1 t I 11 / I Ell LA LA CSANDSAGS (TYP.) OR STAPLES 10MIL SILT FENCE SIDE SLOPE LININGC SANDBAGS(TYP.) OR STAPLES qzX CLEARLY MARKED SIGNAGE CONCRETE NOTING DEVICE (IS'X24-MIN) WASHOUT PLAN SECTION A -A NOTES- 1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75%OF THE STRUCTURES CAPACITY. 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. BELOW GRADE WASHOUT STRUCTURE NOT TO SCALE t0' o2 SANDBAGS(TYR) OR STAPLES 7 CLEARLY MARKED SIGNAGE CONCRETE NOTING DEVICE 18"X24•MIN. ( ) WASHOUT PLAN 40 MIL PLASTIC LINING -1:1 SIDE SLOPE SECTION B-B NOTES: 1. ACTUAL LOCATION DETERMINED INFIELD 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75%THE STRUCTURES CAPACITY TO PROVIDE ADEQUATE HOLDING CAPACITY WITH MINIMUM 12 INCHES OF FREEBOARD. 3. CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. ABOVE GRADE WASHOUT STRUCTURE NOT TO SCALE 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. NCGOI GROUND STABILIZATION AND MATERIALS HANDLING REV. No. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 03127/20 C 90Y.DESIGN-NOT FOR CONSTRUCTION 03/13/20 B 80%DESIGN- NOT FOR CONSTRUCTION 02/07/20 A 30-A DESIGN - NOT FOR CONSTRUCTION 11/16/19 REVISIONS \�tUtluuUl7 . CARp�� �t : C0 049224 ''.,itP�•. FhGINEF;`�.�G,��2`�0. EFFECTIVE: 04/01/19 V - v,NIIFK &CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF -INSPECTION Self -inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which It is safe to perform the inspection. In addition when a storm event of equal to or P P q greater than 1.0 Inch occurs outside of normal business hours, the self -inspection shall be performed upon the commencement of the next business day. Any time when inspections were delayed shall be noted in the Inspection Record. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. Frequency Inspect (during normal Inspection records must Include: business hours) (1J Rain gauge Dolly Dolly rainfall amounts. maintained In Ir no daily rain gauge observations are made during weekend or good working g 8 holiday periods, and no Individual-da rainfall Information Is Y P Y order available record the cumulative rain measurement for those un- attended days and this will determine if a site inspection is I sp needed). Days on which no rainfall occurred shall be recorded as "zero." The permittee may use another rain -monitoring device approved by the Division. At least once per (2J E&SC 1. Identification of the measures inspected, Measures 7 relendar days 2. Date and time of the inspection, and within 24 3. Name of the person performing the inspection, hours of a rain 4. Indication of whether the measures were operating even[ s 1.0 Inch in properly, 24 hours S. Description of maintenance needs for the measure, 6. Description, evidence, and date of corrective actions taken. (3J Acrmwater Al least once per 1. Identifica lion of the discharge outfalls inspected, discharge 7calendar days 2. Date and time of the inspection, outfalls I5005J and within 24 3. Name of the person performing the Inspection, hours ofa rain 4. Evidence of indicators aF stormwater pollution such as oil event > 1.0 inch in sheen, floating or suspended solids or discoloration, 24 hours 5. Indication of visible sediment leaving the site, 6. Description,evidence, and date of corrective actions taken. If visible sedimentation is found outside site limits, then a record (47 Perimeter of At (east once per site 7calendar days of the fallowing shall be made: and within 24 1. Anions taken to cleanup or stabilize the sediment that has left hours of a rain the site limits, event> 1.0 inch in 2. Description, evidence, and date of corrective actions taken, and 24 hours 3. An explanation as to the actions taken to control future P releases. (5) Streams or At least once per If the stream or wetland has Increased visible sedimentation or a wetlands onsite 7calendar days stream has visible Increased turbidity From the construction or offsite and within 24 activity, then a record of the fallowing shall be made: (where hours of a rain 1. Description, evidence and date of corrective actions taken, and accessible) event> 1.0 inch in 2. Records of the required reports to the appropriate Division 24 hours Regional Office per Pan III, Section C, Item (2)Ia) of this permit. (6) Ground Aker each phase 1. The Phase of grading (installation of perimeter E&SC stabilization of grading measures, clearing and grubbing, installation of storm measures drainage facilities, completion of all land -disturbing activity, construction or redevelopment, permanent round PART III SELF -INSPECTION, V1!10114161xlC[d SECTION B: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage underthis permit. The following Items pertaining to the E&SC plan shall be kept on site and available for inspection at all times during normal business hours. Item to Document Documentation Requirements (a) Each E&SC measure has been installed Initial and date each E&SC measure on a copy and does not significantly deviate from the of the approved E&SC plan or complete, date locations, dimensions and relative elevations and sign an inspection report that lists each shown on the approved E&SC plan. E&SC measure shown on the approved E&SC plan. This documentation is required upon the initial installation of the E&SC measures or if the E&SC measures are modified after initial installation. (b) A phase of grading has been completed. Initial and date a copy of the approved E&SC plan or complete, date and sign an inspection report to indicate completion of the construction phase. (c) Ground cover is located and installed Initial and date a copy of the approved E&SC in accordance with the approved E&SC plan or complete, date and sign an inspection plan. report to indicate compliance with approved ground cover specifications. (d) The maintenance and repair Complete, date and sign an inspection report. requirements for all E&SC measures have been performed. (e) Corrective actions have been taken Initial and date a copy of the approved E&SC to E&SC measures. plan or complete, date and sign an inspection report to indicate the completion of the corrective action. 2. Additional Documentation to be Kept on Site In addition to the E&SC plan documents above the following Items shall be kept on the site and available for inspectors at all times during normal business hours, unless the Division provides aaite-specific exemption based on unique site conditions that make this requirement not practical: (a) This General Permit as well as the Certificate of Coverage, after it is received. (b) Records of inspections made during the previous twelve months. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically -available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard -copy records. 3. Documentation to be Retained for Three Years All data used to complete the a-NOI and all inspection records shall be maintained for a period of three years after project completion and made available upon request [40 CFR 122.411 PART II, SECTION G, ITEM (4) DRAW DOWN OF SEDIMENT BASINS FOR MAINTENANCE OR CLOSE OUT Sediment basins and traps that receive runoff from drainage areas of one acre or more shall use outlet structures that withdraw water from the surface when these devices need to be drawn down for maintenance or close out unless this is infeasible. The circumstances in which it is not feasible to withdraw water from the surface shall be rare (for example, times with extended cold weather). Non -surface withdrawals from sediment basins shall be allowed only when all of the following criteria have been met: (a) The E&SC plan authority has been provided with documentation of the non -surface withdrawal and the specific time periods or conditions in which it will occur. The non -surface withdrawal shall not commence until the E&SC plan authority has approved these items, (b) The non -surface withdrawal has been reported as an anticipated bypass in accordance with Part III, Section C, Item (2)(c) and (d) of this permit, (c) Dewatering discharges are treated with controls to minimize discharges of pollutants from stormwater that is removed from the sediment basin. Examples of appropriate controls include properly sited, designed and maintained dewatering tanks, weir tanks, and filtration systems, (d) Vegetated, upland areas of the sites or a properly designed stone pad is used to the extent feasible at the outlet of the dewatering treatment devices described in Item (c) above, (e) Velocity dissipation devices such as check dams, sediment traps, and riprap are provided at the discharge points of all dewatering devices, and (f) Sediment removed from the dewatering treatment devices described in Item (c) above is disposed of in a manner that does not cause deposition of sediment into waters of the United States. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that Must be Reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: • They are 25 gallons or more, • They are less than 25 gallons but cannot be cleaned up within 24 hours, • They cause sheen on surface waters (regardless of volume), or • They are within 100 feet of surface waters (regardless of volume). c Releases of hazardous substances in excess of reportable quantities under Section 311 (1 P of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (d) Anticipated bypasses and unanticipated bypasses. (e) Noncompliance with the conditions of this permit that may endanger health or the environment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and In accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Department's Environmental Emergency Center personnel at (800) 858-0368. Occurrence Reporting Timeframes (After Discovery) and Other Requirements t a Vislb a sedimen 11 Within 24 boon• an oral or electronic notification. deposition in a • Within 7 calendar days, a report that contains a description of the stream or wetland sediment and actions taken to address the cause of the deposition. Division staff may waive the requirement for a written report on a case -by -case basis. • If the stream is named on the NC 303 d list as impaired for sediment - related causes, the permittee may be required to perform additional monitoring, inspections or apply more stringent practices If staff determine that additional requirements are needed to assure compliance with the federal orstate impaired -waters conditions. (b) Oil spills and • Within 24 hours, an oral or electronic notification. The notification release of shall include information about the date time nature volume and hazardous location of the spill or release. P I substances per Item 1(b)-(c) above (c) Anticipated • A report at least ten days before the date of the bypass, If possible. bypasses [40 CFR The report shall include an evaluation of the anticipated quality and 122.41(m)(3)] effect of the bypass. (d) Unanticipated • Within 24hours, an oral or electronic notification. bypasses [40 CFR 122.41(m)(3)] • Within 7mlendardays, a report that includes an evaluation of the quality and effect of the bypass. (e) Noncompliance • Within 24houn, an oral or electronic notification. with the conditions • Within 7mlendardays, a report that contains a description of the of this permit that noncompliance, and its causes; the period of noncompliance, may endanger including exact dates and times, and if the noncompliance has not health or the been corrected, the anticipated time noncompliance is expected to environment[40 continue; and steps taken or planned to reduce, eliminate, and CFR 122.41(I)(7)] prevent reoccurrence of the noncompliance. [40 CFR 122.41(I)(6). • Division staff may waive the requirement for a written report on case -by -case basis. NCGOI SELF -INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/191 JOHNSTON COUNTY DEPARTMENT OF UTILITIES JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS DETAILS EROSION AND SEDIMENT CONTROL DETAILS PROD. START DATE: 2019.NOV MICE PROJ. # 0036"141 DRAWN DWH DESIGNED WON CHECKED AJP PROJ. MGR. AJP SCALE D5 HORIZONTAL: DRAWING NUMBER VERTICAL: 1„.4. D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\DETAILS\CD.01-003580141-J000385-DETAILS.DWG 03/27/2020 10:36:03 DAVID HAMMOND EC-011 EROSION CONTROL CONSTRUCTION SEQUENCE N.T.S. I IEC-021 EROSION CONTROL GENERAL NOTES N.T.S. I I EC-031 SEEDBED PREPERATION .1111100I 1. THE INTENT OF THE CONSTRUCTION SEQUENCE IS TO PROVIDE THE CONTRACTOR WITH A GENERAL GUIDE FOR CONSTRUCTION PURPOSES. THIS SEQUENCE IS NOT INTENDED TO OUTLINE ALL CONSTRUCTION ACTIVITIES ON THIS PROJECT. 2. CONTRACTOR SHALL ARRANGE PRE -CONSTRUCTION MEETING WITH THE OWNER'S REPRESENTATIVE, ENGINEER, JOHNSTON COUNTY AND NCDEQ-LAND QUALITY SECTION REPRESENTATIVE (919-791-4200) PRIOR TO ANY LAND DISTURBING ACTIVITY ON SITE. 3. EROSION AND SEDIMENT CONTROL (E&SC) PERMIT AND CERTIFICATE OF COVERAGE MUST BE OBTAINED BEFORE ANY LAND DISTURBING ACTIVITIES OCCUR. THE CDC CAN BE OBTAINED BY FILLING OUT THE ELECTRONIC NOTICE OF INTENT (e-N01) FORM AT DEQ.NC.GOV/NCGO1. PLEASE NOTE, THE a-N01 FORM MAY ONLY BE FILLED OUT ONCE THE PLANS HAVE BEEN APPROVED. A COPY OF THE E&SC PERMIT, THE COC, AND A HARD COPY OF THE PLAN MUST BE KEPT ON SITE, PREFERABLY IN A PERMITS BOX, AND ACCESSIBLE DURING INSPECTION. 4. WHEN THE PROJECT IS COMPLETE, THE PERMITTEES SHALL CONTACT DEMLR TO CLOSE OUT THE E&SC PLAN. AFTER DEMLR INFORMS THE PERMITTEE OF THE PROJECT CLOSE OUT, VIA INSPECTION REPORT, THE PERMITTEE SHALL VISIT DEQ.NC.GOV/NCGO1 TO SUBMIT AN ELECTRONIC NOTICE OF TERMINATION (e-NOT). A $100 ANNUAL GENERAL PERMIT FEE WILL BE CHARGED UNTIL THE a -NOT HAS BEEN FILLED OUT. 5. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE NORTH CAROLINA EROSION AND SEDIMENTATION CONTROL PLANNING AND DESIGN MANUAL. 6. ALL EROSION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER RAINFALL EVENTS. NEEDED REPAIRS SHALL BE MADE IMMEDIATELY. 7. IF IT IS DETERMINED DURING CONSTRUCTION THAT ANY SEDIMENT IS LEAVING THE SITE, DESPITE PROPER IMPLEMENTATION AND MAINTENANCE, THE CONTRACTOR IS OBLIGATED TO TAKE ADDITIONAL CORRECTIVE ACTION. CONTACT OWNER'S REPRESENTATIVE AND ENGINEER WITH ANY ADDITIONAL MEASURES NEEDED. 8. CONTRACTOR SHALL ESTABLISH GROUNDCOVER ON DISTURBED AREAS WITHIN DAYS SPECIFIED BY THE NPDES GENERAL PERMIT STABILIZATION REQUIREMENTS AFTER COMPLETION OF ANY PHASE OF GRADING. SEEDING SHALL BE IN ACCORDANCE WITH EC-6 AND EC-7 ON THIS SHEET. 9. MAINTAIN A COPY OF THE LETTER OF PLAN APPROVAL ON SITE FOR SEDIMENTATION AND EROSION CONTROL FROM NCDEQ-LAND QUALITY SECTION AS WELL AS THE PREVIOUS 30 DAYS OF SELF INSPECTION RECORDS, RAIN GAUGE, APPROVAL CERTIFICATE/LETTER, APPROVED PLAN, NODES PERMIT, AND ANY 401/404 DOCUMENTATION. THESE ITEMS SHOULD BE LOCATED NEAR THE MAIN CONSTRUCTION ENTRANCE. COORDINATE WITH THE INSPECTOR IF AN ALTERNATIVE LOCATION IS PREFERRED. ADDITIONAL INFORMATION AND A LINK TO THE NCG01 COMBINED SELF -MONITORING FORM CAN BE FOUND AT: HTTPS: //DEQ.NC.GOV/ABOUT/DIVISIONS/ENERGY-MINERAL-LAND- RESOURCES/ENERGY-MINERAL-LAND-PERMITS/STORMWATER- PERMITS/CON STRUCTION-SW. 10. CONTRACTOR TO POST ANY NECCESSARY GRADING PERMIT PROMINENTLY ON SITE AT ALL TIMES. 11. CONTRACTOR TO VERIFY LOCATION AND DEPTH OF EXISTING UTILITIES TO AVOID CONFLICT DURING INSTALLATION OF EROSION CONTROL MEASURES, STORM SEWER PIPES AND UNDERGROUND UTILITY LINES. CONTRACTOR IS TO CALL 1-800-632-4949 FOR "NC ONE CALL" OR "811" TO HAVE EXISTING UTILITIES LOCATED. 12. CONTRACTOR TO HAVE A PROFESSIONAL LAND SURVEYOR FLAG PROPERTY LINES, EASEMENTS, STREAM BUFFERS, TREE PROTECTION AREAS AND LIMITS OF DISTURBANCE PRIOR TO LAND DISTURBING ACTIVITIES. 13.INSTALL TEMPORARY GRAVEL ACCESS POINTS PER THE CONSTRUCTION ACCESS AND TRAFFIC CONTROL PLANS. INSTALL CONSTRUCTION ENTRANCES WHERE REQUIRED TO ACCESS WORK AREAS. 14. INSTALL TEMPORARY SILT FENCE, SUPER SILT FENCE, HIGH HAZARD SILT FENCE, TREE PROTECTION FENCE AND OTHER MEASURES AS SHOWN ON PLANS. SILT FENCE SHOULD BE INSTALLED ON ALL DOWNSLOPE PORTIONS OF THE DISTURBED AREA. SILT FENCE SHOULD NOT BE INSTALLED ON THE HIGH SIDE OF THE DISTURBANCE AREA (TREE PROTECTION FENCING IS AN ACCEPTABLE ALTERNATIVE IF DESIRED). SILT FENCE OUTLETS SHOULD BE INSTALLED AT ALL LOW SPOTS AND ANYWHERE WATER IS POOLING. SILT FENCE AND OUTLET LOCATIONS MAY VARY FROM THE APPROVED PLANS PER SITE CONDITIONS. CONTRACTOR SHALL PROVIDE SILT FENCE AROUND ALL BORROW/STOCKPILE/WASTE AREAS, ALL LAYOUT/STAGING AREAS, AND ALONG EITHER SIDE OF ALL TEMPORARY CONSTRUCTION ACCESS ROADS/CORRIDORS. EC-061 TEMPORARY SEEDING SCHEDULE 9:,... 2 9 � 1 9 4 SPECIES: RATE (Ib/acre): RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN 50 PIEDMONT & COASTAL PLAIN, KOREAN IN MOUNTAINS) OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE SEEDING DATES: MOUNTAINS (ABOVE 2,500'): FEB. 15 - MAY 15 15. CONTRACTOR TO INSTALL EROSION CONTROL MEASURES AS SHOWN AND DETAILED IN THESE PLANS. CONTRACTOR TO PHASE THE OVERALL EROSION CONTROL BASED ON INSTALLATION OF THE SEWER LINE. CONTRACTOR TO COORDINATE THE EROSION CONTROL INSTALLATION WITH JOHNSTON COUNTY AND NCDEQ. 16. CONTRACTOR TO REFER TO THE TEMPORARY WETLAND CROSSING DETAIL (EC-21) AS REQUIRED DURING THE INSTALLATION OF THE SEWER LINE. CONTRACTOR TO PROVIDE ADDITIONAL EROSION CONTROL MEASURES AS NEEDED DURING STREAM AND WETLAND CROSSINGS. CONTRACTOR TO MINIMIZE THE IMPACTS TO STREAMS AND WETLANDS DURING INSTALLATION. 17. TEMPORARY INLET PROTECTION TO BE INSTALLED AS SHOWN ON THE PLANS. THESE DEVICES ARE TO REMAIN IN PLACE UNTIL THE SITE HAS BEEN STABILIZED AND APPROVAL FOR REMOVAL HAS BEEN GIVEN. 18. INSTALL INLET PROTECTION, AND STRAW WATTLES AS SHOWN ON PLANS WHEN CONTRACTOR IS WORKING IN THESE AREAS. THE DEVICES ARE TO REMAIN IN PLACE UNTIL THE AREA IS STABILIZED AND APPROVAL FOR REMOVAL HAS BEEN GIVEN BY NCDEQ-LAND QUALITY SECTION AND ENGINEER. 19. OPEN TRENCH, INSTALL AND BACKFILL TRENCH DAILY. WHEN BACKFILLING THESE AREAS, STABILIZATION SHALL BE INSTALLED PER APPLICABLE DETAIL. 20. CONTRACTOR IS TO DEWATER THE OPENED TRENCH DAILY AS NEEDED BUT AT A MINIMUM AFTER EVERY RAINFALL EVENT. 21. WHEN STABILIZING RIPARIAN BUFFERS AND WETLAND CROSSINGS, CONTRACTOR IS TO PLANT SEED PER THE SEEDING SCHEDULE SHOWN ON DETAIL EC-5. 22. CONTRACTOR TO STABILIZE STREAM BANKS PER DETAIL EC-12. 23. THE CONTRACTOR SHALL STABILIZE WETLAND, RIPARIAN BUFFERS AND STREAM CROSSINGS AT THE TIME OF THE ACTUAL CROSSING. CONTRACTOR TO UTILIZE EXTREME CAUTION TO ENSURE THESE AREAS ARE STABILIZED AND THAT NO SEDIMENT ENCROACHES DOWNSTREAM OF THESE CROSSINGS. 24. SPOIL PLACEMENT SHALL BE ON THE UPSTREAM SIDE OF THE TRENCH ONLY. ANY ADDITIONAL EXCAVATED MATERIAL IS TO HAULED OFF AND DISPOSED OF IN AN APPROVED LANDFILL AT THE CONTRACTORS EXPENSE. 25. ANY DEWATERING ON THE PROJECT SHALL BE DONE THOUGH A SILT BAG. 26. STABILIZE SITE AS TRENCH IS RESTORED TO ORIGINAL GRADE WITH VEGETATION AND/OR PAVING AS SHOWN ON PLANS. THIS STABILIZATION IS TO BE COMPLETED DAILY. 27. PERFORM SEEDING AND MULCHING AS REQUIRED IN ACCORDANCE WITH THE EROSION CONTROL (EC) DETAILS AND TECHNICAL SPECIFICATIONS. 28.REMOVE TEMPORARY CONSTRUCTION ENTRANCES WHEN WORK IS COMPLETE IN AN AREA AND BRING AREAS BACK TO ORIGINAL GRADES AS REQUIRED. 29. ONCE ALL GROUNDCOVER HAS BEEN ESTABLISHED IN A SPECIFIC AREA, THE CONTRACTOR SHALL CONTACT NCDEQ-LAND QUALITY SECTION AND ENGINEER FOR SITE INSPECTION BEFORE REMOVING ANY TEMPORARY EROSION CONTROL MEASURES. 30. ONCE AREA HAS BEEN APPROVED FOR REMOVAL OF EROSION AND SEDIMENTATION MEASURES, CONTRACTOR SHALL REMOVE THESE MEASURES AND INSTALL PERMANENT SEEDING PER DETAIL EC-7. 31. AFTER THE ENTIRE SITE IS COMPLETELY STABILIZED, CONTRACTOR SHALL REQUEST PERMISSION FROM NCDEQ-LAND QUALITY SECTION AND ENGINEER TO REMOVE ALL TEMPORARY MEASURES. ONCE APPROVAL IS GIVEN, REMOVE ALL TEMPORARY MEASURES AND INSTALL PERMANENT VEGETATION AS REQUIRED AND ON ANY RESULTING BARE AREAS. REPAIR ANY AREAS DISTURBED DURING REMOVAL. N.T.S. (BELOW 2,500'): FEB. 1 - MAY 1 PIEDMONT: JAN. 1 - MAY 1 COASTAL PLAIN: DEC. 1 - APR. 15 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 750 lb/acre 10-10-10 FERTILIZER. MULCH: APPLY 4.000 lb/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT (min. 400 gal/acre), NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. 0JI3p1IUezMK4M SPECIES: RATE (lb/acre): RYE (GRAIN) 120 SEEDING DATES: MOUNTAINS: AUG. 15 - DEC. 15 COASTAL PLAIN AND PIEDMONT: AUG. 15 - DEC. 30 SOIL AMENDMENT'S: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 750 lb/acre 10-10-10 FERTILIZER MULCH: APPLY 4.000 lb/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT (min. 400 gal/acre), NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. IF CRIMPING IS TO BE USED, INSTALL 1/2 OF THE MULCH, THEN CRIMP, AND INTSALL THE OTHER 1/2 OF MULCH ON TOP. MAINTENANCE: REPAIR AND REFERTILIZE DAMAGED AREAS IMMEDIATELY. TOPDRESS WITH 50 lb/acre OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVERSEED WITH 50 lb/acre KOBE (PIEDMONT AND COASTAL PLAIN) OR KOREAN (MOUNTAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. RECOMMENDATIONS FOR SUMMER SEEDING MIXTURE: SPECIES: RATE (lb/acre): GERMAN MILLET 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL -STEMMED SUDANGRASS MAY BE SUBSTITUTED AT A RATE OF 50 lb/acre. SEEDING DATES: MOUNTAINS MAY 15 - AUG. 15 PIEDMONT: MAY 1 - AUG. 15 COASTAL PLAIN: APR. 15 - AUG. 15 SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 750 lb/acre 10-10-10 FERTILIZER MULCH: APPLY 4.000 lb/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT (min. 400 gal/acre), NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. IF CRIMPING IS TO BE USED, INSTALL 1/2 OF THE MULCH, THEN CRIMP, AND INTALL THE OTHER 1/2 OF MULCH ON TOP. MAINTENANCE: REFERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, REFERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING -NOT FOR CONSTRUCTION 03/27120 C BO'DESIGN- NOT FOR CONSTRUCTION 03113= B 60%DESIGN- NOT FOR CONSTRUCTION 02/07/20 A 30%DESIGN - NOT FOR CONSTRUCTION 11/1919 REVISIONS 1. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE NORTH CAROLINA EROSION AND SEDIMENTATION CONTROL PLANNING AND DESIGN MANUAL. 2. ALL EROSION CONTROL MEASURES SHALL BE INSPECTED WEEKLY AND AFTER RAINFALL EVENTS. NEEDED REPAIRS SHALL BE MADE IMMEDIATELY. 3. ADDITIONAL SEDIMENT AND EROSION CONTROL MEASURES MAY NEED TO BE INSTALLED IF DEEMED NECESSARY BY EITHER THE ENGINEER OR ENVIRONMENTAL INSPECTOR. 4. ALL EROSION AND SEDIMENT CONTROL MEASURES MUST BE MAINTAINED UNTIL ALL UPGRADE DRAINAGE AREAS HAVE BEEN STABILIZED WITH THE ESTABLISHMENT OF PERMANENT VEGETATION. 5. DUST ON SITE SHALL BE MINIMIZED BY SPRAYING WATER ON DRY AREAS OF THE SITE. THE USE OF OILS AND OTHER PETROLEUM BASED OR TOXIC LIQUIDS FOR DUST SUPPRESSION IS STRICTLY PROHIBITED. 6. IF THE MAJORITY OF MUD OR DIRT IS NOT REMOVED FROM CONSTRUCTION TRAFFIC BY CONSTRUCTION ENTRANCES, CONTRACTOR SHALL CONSTRUCT VEHICLE WASH AREAS AT CONSTRUCTION TRAFFIC EXIT POINTS. MUD AND DIRT SHALL BE INTERCEPTED AND TRAPPED BEFORE WASH WATER IS ALLOWED TO BE DISCHARGED OFFSITE. RINSE -OFF WILL NOT BE ALLOWED OUTSIDE THE PROJECT CONSTRUCTION LIMITS. 7. SEDIMENT SHALL BE REMOVED FROM BEHIND THE SILT FENCE WHEN IT REACHES 1-FOOT DEEP. B. MAXIMUM GRADED SLOPE SHALL NOT EXCEED 3:1. 9. NO CONCRETE OR CEMENT SLURRY SHALL BE DISCHARGED FROM THE SITE. ANY HARDENED CONCRETE RESIDUE WILL BE DISPOSED OF, OR RECYCLED OFF SITE, IN ACCORDANCE WITH LOCAL AND STATE SOLID WASTE REGULATIONS. 10. ALL SWALES, DITCHES, PERIMETER SLOPES AND ALL SLOPES STEEPER THAN 3 HORIZONTAL TO 1 VERTICAL (3:1) SHALL BE PROVIDED TEMPORARY OR PERMANENT STABILIZATION WITH GROUND COVER AS SOON AS PRACTICABLE BUT IN ANY EVENT PER THE STABILIZATION TIMEFRAMES DETAILED IN THESE PLANS. (REFER TO DETAIL EC-3.1). REFER TO EROSION CONTROL DETAILS FOR ADDITIONAL REQUIREMENTS. 11. CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING A PERMIT FOR ANY BORROW AND/OR SPOIL AREAS OR DISTURBED AREAS NOT SHOWN ON THESE PLANS. THIS SHALL INCLUDE ALL COST ASSOCIATED WITH OBTAINING PERMIT. 12. CONTRACTOR SHALL FOLLOW EROSION CONTROL CONSTRUCTION SEQUENCE UNLESS GIVEN WRITTEN APPROVAL FROM ENGINEER FOR VARIANCE. 13. LIMITS OF DISTURBANCE SHALL BE PHASED THROUGHOUT THE PROJECT SITE. DISTURBANCE TIMEFRAMES FOR TEMPORARY STREAM AND WETLAND CROSSINGS ARE TO BE MINIMIZED. CONTRACTOR TO COORDINATE THE DISTURBANCE LENGTH WITH THE CITY OF DURHAM AND NCDEQ. 14. IF RIP -RAP IS NOT REQUIRED AND STRAW WITH TACK LINER IS TO BE USED, WATER COURSE SHALL BE SEEDED PER SIDE DITCH SEEDING SCHEDULE DETAIL USING SEEDBED PREPARATION SCHEDULE DETAIL. 15. TOTAL DISTURBED AREA IS 11.47 ACRES. 16. WOODMAT SHALL HAVE SIDE PANELS TO PREVENT MATERIAL FROM FALLING OFF THE SIDES AND INTO THE WETLAND/STREAM. 17.IN SOME CASES A WATER BAR ABOVE STREAM CROSSING MAY BE NEEDED TO PREVENT RUNOFF ON THE CONSTRUCTION ENTRANCE FLOWING DOWN TO THE STREAM. 18. ALL WORK WITHIN BUFFERS AND WETLANDS SHALL BE STABILIZED AT THE END OF EACH WORK DAY (COVER STOCKPILES WITH MATTING/TARPS, SEED/MULCH, ETC) 19. COMPOST SOCK MAY BE SUBSTITUTED FOR SILT FENCE OUTLET GRAVEL, SLOPE BREAKS, CHECK DAMS AND INLET PROTECTION. THE COMPOST SOCK MUST BE INSTALLED PER MANUFACTURER SPECIFICATIONS. THEY MUST BE SIZED TO PREVENT OVERTOPPING. FOR SILT FENCE OUTLETS, THE INSTALLED HEIGHT CAN BE NO LESS THAN 16 INCHES. WATTLES, COIR LOGS, FILTER LOGS, ETC. ARE NOT ACCEPTABLE FOR THESE USES. 20. UTILIZE SILT FENCE J-HOOKS AT SILT FENCE OUTLET LOCATIONS IN WHICH THE RUNOFF FLOW DIRECTION IS PARALLEL TO THE OUTLET. THIS WILL HELP PREVENT OUTLET BYPASS AND REDUCE RUNOFF ALONG THE SILT FENCE. 21. PLACE A LAYER OF SAND, SCREENINGS OR FINES ON PAVED SURFACES PRIOR TO DEPOSITION OF EXCAVATED MATERIALS. THESE AREAS ARE TO BE WITHIN THE PERMITTED LIMITS OF DISTURBANCE. EC-071 PERMANENT SEEDING SCHEDULE RECOMMENDATIONS FOR LATE WINTER AND EARLY SPRING SEEDING MIXTURE: SPECIES: RATE (lb/acre): TALL FESCUE 300 KOBE LESPEDEZA 40 NURSE PLANTS: BETWEEN MAY 1 AND AUG. 15, ADD 10 lb/acre GERMAN MILLET OR 15 lb/acre SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 40 Ib/ac RYE (GRAIN) SEEDING DATES: BEST: POSSIBLE: FALL AUG. 15 - SEPT. 15 AUG. 20 - OCT. 25 LATE WINTER: FEB. 15 - MAR. 21 FEB. 1 - APR. 15. FALL IS BEST FOR TALL FESCUE AND LATER WINTER FOR LESPEDEZAS. OVERSEEDING OF DOBE LESPEDEZA OVER. FALL -SEEDED TALL FESCUE IS VERY EFFECTIVE. SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 750 lb/acre 10-10-10 FERTILIZER MULCH: APPLY 4.000 lb/acre STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT (min. 400 gal/acre), NETTING OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE: REFERTILIZE IN THE SECOND YEAR UNLESS GROWTH IS FULLY ADEQUATE. MAY BE MOWED ONCE OR TWICE A YEAR, BUT MOWING IS NOT NECESSARY. RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. RECOMMENDATIONS FOR GRASS -LINED CHANNELS SEEDING MIXTURE: SPECIES RATE (lb/acre) TALL FESCUE 300 NURSE PLANTS: BETWEEN MAY 1 AND AUG. 15, ADD 10 lb/acre SUDANGRASS OR 15 lb/acre GERMAN MILLET. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 40 Ib/ac RYE (GRAIN) SEEDING DATES: BEST: AUG. 25 - OCT. POSSIBLE: FEB. - APR. 15 AVOID SEEDING FROM NOV. TO JAN. IF SEEDING MUST BE DONE AT THIS TIME, ADD 40 lb/acre RYE GRAIN AND USE A CHANNEL LINING THAT OFFERS MAXIMUM PROTECTION SOIL AMENDMENTS: FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 4,000 lb/acre GROUND AGRICULTURAL LIMESTONE AND 1,000 lb/acre 10-10-10 FERTILIZER MULCH: USE ROLLED EROSION CONTROL PRODUCT TO COVER THE BOTTOM OF THE CHANNELS AND DITCHES, AND STAPLE SECURELY. THE LINING SHOULD EXTEND TO THE TOP OF BANK. ON CHANNEL SIDE SLOPES ABOVE THIS HEIGHT, AND IN DRAINAGES NOT REQUIRING TEMPORARY LININGS, APPLY 4,000 lb/acre GRAIN STRAW, AND ANCHOR STRAW BY STAPLING NETTING OVER THE TOP. MULCH AND ANCHORING MATERIALS MUST NOT BE ALLOWED TO WASH DOWN SLOPES WHERE THEY CAN CLOG DRAINAGE DEVICES. MAINTENANCE: INSPECT AND REPAIR MULCH FREQUENTLY. REFERTILIZE IN LATE WINTER OF THE FOLLOWING YEAR; USE SOIL TESTS OR APPLY 150 lb/acre 10-10-10. MOW REGULARLY TO A HEIGHT OF 2-4 INCHES. v 1Vi MM&CREED Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com 1. CHISEL COMPACTED AREAS AND SPREAD TOPSOIL 3 INCHES DEEP OVER ADVERSE SOIL CONDITIONS, WHERE REQUIRED. 2. RIP THE ENTIRE AREA TO 6 INCHES DEPTH. 3. REMOVE ALL LOOSE ROCK, ROOTS, AND OTHER OBSTRUCTIONS LEAVING SURFACE REASONABLY SMOOTH AND UNIFORM. 4. APPLY AGRICULTURAL LIME, FERTILIZER, AND SUPERPHOSPHATE UNIFORMLY AND MIX WITH SOIL (SEE EC-4). 5. CONTINUE TILLAGE UNTIL A WELL - PULVERIZED, FIRM, REASONABLY UNIFORM SEEDBED IS PREPARED 4 TO 6 INCHES DEEP. 6. SEE EC-4 FOR PERMANENT SEEDING SCHEDULE. 7. SEED ON A FRESHLY PREPARED SEEDBED AND COVER SEED LIGHTLY WITH SEEDING EQUIPMENT OR CULTIPACK AFTER SEEDING. B. MULCH IMMEDIATELY AFTER SEEDING AND ANCHOR MULCH. 9. INSPECT ALL SEEDED AREAS AND MAKE NECESSARY REPAIRS OR RESEEDINGS WITHIN THE PLANTING SEASON, IF POSSIBLE. IF STAND SHOULD BE OVER 60% DAMAGED REESTABLISH FOLLOWING ORIGINAL LIME, FERTILIZER AND SEEDING RATES. 10. CONSULT CONSERVATION INSPECTOR ON MAINTENANCE TREATMENT AND FERTILIZATION AFTER PERMANENT COVER IS ESTABLISHED. EC-041 SOIL STOCKPILE MAINTENANCE REQUIREMENTS N.T.S. 1. EXCAVATED MATERIAL FROM TRENCHES ARE TO BE PLACED ON THE UPSTREAM SIDE OF THE TRENCH. NO ADDITIONAL "STOCKPILE" AREAS ARE TO BE UTILIZED OUTSIDE OF THE EXISTING LIMITS OF DISTURBANCE. 2. SEEDING OR COVERING OF STOCKPILES WITH TARPS OR MULCH IS REQUIRED AND WILL REDUCE EROSION PROBLEMS. TARPS SHOULD BE KEYED IN AT THE TOP OF THE SLOPE TO KEEP WATER FROM RUNNING UNDER THE PLASTIC. 3. THE APPROVED PLAN SHALL PROVIDE FOR THE USE OF STAGED SEEDING AND MULCHING ON A CONTINUAL BASIS WHILE THE STOCKPILE(S) ARE IN USE. 4. STOCKPILE HEIGHT SHALL NOT EXCEED 10 FEE TALL. 5, STOCKPILE SLOPES SHALL BE 2:1 OR FLATTER. EC-051 ZONE 1 RIPARIAN BUFFER RESTORATION NOTES N.T.S. WITHIN AREAS THAT WILL BE TEMPORARILY DISTURBED, THE APPLICANT WILL BE RESPONSIBLE FOR FULFILLING THE FOLLOWING REQUIREMENTS: 1. TWO DIFFERENT NATIVE TREE, SHRUB, OR FOREST SPECIES SHALL BE PLANTED IN ALL TEMPORARILY DISTURBED ZONE 1 RIPARIAN BUFFER AREAS AT A DENSITY TO PROVIDE 260 TREES PER ACRE AT MATURITY. 2. TREE PLANTING DENSITY SHALL BE APPROXIMATELY 436 (10 X 10 TREE SPACING) TO 681 (8 X 8 TREE SPACING) TREES PER ACRE. 3. ESTIMATED CONSTRUCTION START DATE IS JUNE 2020 AND ESTIMATED CONSTRUCTION COMPLETION DATE IS MARCH 2O22. RESTORATION OF TREES, SHRUBS, AND FOREST SHALL BE COMPLETED BY THE FIRST SUBSEQUENT PLANTING SEASON, BETWEEN NOVEMBER 1ST AND MARCH 30TH. 4. A ONE-TIME FERTILIZATION OF TREES WILL OCCUR, SHOULD FERTILIZATION BE NECESSARY BASED ON GROWTH. 5. A VISUAL MONITORING REPORT OF THE RESTORED AREAS IS REQUIRED AT A MINIMUM OF QUARTERLY FOR THE FIRST YEAR AND THEN ANNUALLY UNTIL THE SITE IS STABLE AND VEGETATION IS SUCCESSFUL. VEGETATION SUCCESS IS DEFINED AS A TREE DENSITY SUFFICIENT TO PROVIDE 260 TREES PER ACRE AT MATURITY. N.T.S. RECOMENDATIONS FOR RIPARIAN BUFFERS AND WETLANDS SEEDING MIXTURE: RECOMMENDED APPLICATION RATE: 20-25 LBS. PER ACRE SPECIES COMMON NAME PERCENT LYMUS VIRGINICUS RGINIA WILD RYE 15 ANICUM VIRGATUM WITCHGRASS 15 GROSTIS STOLONIFERA EEPING BENTGRASS 10 UDBECKIA HIRTA ACK-EYED SUSAN 1111111WNED 10 OREOPSIS LANCEOLATA REOPSIS 10 ANICUM CLANDESTINUM ER TONGUE 10 NDROPOGON GERARDI G BLUESTEM 5 UNCUS EFUSUS FT RUSH 5 CHINOCHLOA MURICATA BARNYARD GRASS 5 CHIZACHYRIUM SCOPARIUM ITTLE BLUESTEM 5 ORGHASTRUM NUTANS NDIAN GRASS 5 [FRIPSACUM DACTYLOIDES AMMA 5 AS SPECIFIED BY MELLOW MARSH IN SILER CITY OR APPROVED EQUAL. SEEDING DATES: BEST: MAR. 1 - MAY 1 POSSIBLE: OCT. - FEB. NO SEEDING FROM JUNE TO SEPTEMBER. SOIL AMENDMENTS: CONTRACTOR TO WORK COMPOST INTO THE SOILS SURFACE AT A MINIMUM OF 2 INCHES. FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 1,500 lb/acre GROUND AGRICULTURAL LIMESTONE. MAINTENANCE: INSPECT AND REPAIR MULCH FREQUENTLY. MOWING IN AUGUST - SEPTEMBER ONLY TO HELP DISPERSE SEEDS. VOTES: I. SEE NCDENR'S EROSION AND SEDIMENT CONTROL PLANNING DESIGN MANUAL SECTION 6.11 FOR ADDITIONAL PERMANENT SEEDING OPTIONS. 2. IF CRIMPING IS TO BE USED, INSTALL 1/2 OF THE MULCH, THEN CRIMP, AND INSTALL THE OTHER 1/2 OF MULCH ON TOP. JOHNSTON COUNTY DEPARTMENT OF UTILITIES JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS DETAILS EROSION AND SEDIMENT CONTROL DETAILS PROD. START DATE: 2019.NOV MICE PROD. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP SCALE HORIZONTAL: 1"=40' VERTICAL: 1 "=4' 11116 DRAWING NUMBER D STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\DETAILS\CD.01-003580141-J000385-DETAILS.DWG 03/27/2020 14:18:11 DAVID HAMMOND 8' MAX. VARIABLE AS DIRECTED BY THE ENGINEER 8' MAX. VARIABLE AS DIRECTED BY THE ENGINEER PLASTIC OR IT I WIRE TIES Ili!i!;i!i!i!i : PLASTIC OR WIRE TIES MIN. 12-Y2 GA. INTERMEDIATE WIRES FRONT VIEW it CONSTRUCTION SPECIFICATIONS: * FOR REPAIR OF SILT FENCE 1. USE SILT FENCE ONLY WHEN DRAINAGE AREA DOES NOT FAILURES, USE No. 57 EXCEED 1/4 ACRE AND NEVER IN AREAS OF WASHED STONE. CONCENTRATED FLOW 2. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFINS OR POLYESTER, WHICH IS STEEL POST CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE REQUIREMENTS IN ASTM D 6461, WOVEN WIRE FABRIC WHICH IS SHOWN IN PART IN TABLE 6.62B OF THE EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN SILT FENCE FABRIC MANUAL. 3. SYNTHETIC FILTER FABRIC SHOULD CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM FILL SLOPE OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 TO 120' F. 4. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.25 w LB/LINEAR FT MINIMUM STEEL WITH A MINIMUM LENGTH OF 5 FEET. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. r-AND GRADE 5.FOR REINFORCEMENT OF STANDARD STRENGTH FILTERFABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE ANDA MAXIMUM MESH SPACING OF 6 INCHES. 8" MINIMUM COVER MAINTENANCE OVER SKIRT 1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND `� TO BE TRENCHED IN, AT AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRSM, 8-INCHES VERTICALLY IMMEDIATELY. -INCHES HORIZONTALLY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. SIDE VIEW 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. EC-081 TEMPORARY SILT FENCE TOP OF SILT FENCE MUST BE AT LEAST 1' ABOVE THE TOP OF THE WASHED STONE. FRONT VIEW 4' MIN _ I r-SILT FENCE 8' MAX. TREE PROTECTION AREA VARIABLE AS DIRECTED BY THE ENGINEER PLASTIC OR "DOER WIRE TIES MIN. 12-1/2 GA. MIN. 10 GA. INTERMEDIATE LINE W RESOND WIRES TREE PROTECTION AREA GRADE DO NOT ENTER MIN. 12-1/2 GA. MIN. 10 GA. INTERMEDIATE LINE WIRES WIRES - - - GRADE FRONT VIEW j ORANGE, UV RESISTANT * FOR REPAIR OF SILT FENCE HIGH - TENSILE STRENGTH FAILURES, USE No. 57 POLY BARRICADE FABRIC WASHED STONE. (TYPICAL) STEEL POST FRONT VIEW WOVEN WIRE FABRIC NOTES' SILT FENCE FABRIC 1. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF STEEL POST MATERIAL. WOVEN WIRE FABRIC 2. LETTERS TO BE 3" HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. M FILL SLOPE ORANGEUV RESISTANT 3. SIGNS SHALL BE PLACED AT 50' MAXIMUM INTERVALS. , 3 HIGH TENSILE STRENGTH 4. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION N m - FOR TREE PROTECTION ONLY1 POLY BARRICADE FABRIC AND 50' ON CENTER THEREAFTER. 5. FOR TREE PROTECTION AREAS LESS THAN 200'IN PERIMETER, NO 1. WARNING SIGNS TO BE MADE OF DURABLE, WEATHERPROOF MATERIAL. 2. LETTERS TO BE 3" HIGH MINIMUM, CLEARLY LEGIBLE AND SPACED AS DETAILED. 3, SIGNS SHALL BE PLACED AT 50' MAXIMUM INTERVALS. 4. PLACE A SIGN AT EACH END OF LINEAR TREE PROTECTION AND 50' ON CENTER THEREAFTER. 5. FOR TREE PROTECTION AREAS LESS THAN 200'IN PERIMETER, PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. 6. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. 7. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF PROJECT. z uT SKIRT TO BE TRENCHED IN, AT IN LIEU OF BURYING SKIRT, 6" MINIMUM, 8-INCHES VERTICALLY OF #5 WASHED STONE MAYBE USED OVER TURNDOWN. AND 4-INCHES HORIZONTALLY. GENERAL NOTES: CONSTRUCTION SPECIFICATIONS: 1. WIRE FENCING SHALL BE A MINIMUM OF 60" IN WIDTH AND 1. USE A SYNTHETIC FILTER FABRIC OF AT SHALL BE STEEL CHAIN LINK FENCING, MIN #10 GAUGE. LEAST 95% BY WEIGHT OF POLYOLEFINS OR 2. WOVEN FILTER FABRIC BE USED WHERE SILT FENCE IS TO POLYESTER, WHICH IS CERTIFIED BY THE REMAIN FOR A PERIOD OF MORE THAN 30 DAYS MANUFACTURER OR SUPPLIER AS (TYPICAL) , CONFORMING TO THE REQUIREMENTS IN 4� PROVIDE NO LESS THAN ONE SIGN PER PROTECTION AREA. M GRADE 3• STEEL POSTS SHALL BE MIN 7' LONG. POSTS SHALL BE OF ASTM D 6461, WHICH IS SHOWN IN PART IN o FILL SLOPE 6. ATTACH SIGNS SECURELY TO FENCE POSTS AND FABRIC. ADEQUATE SIZE AND THICKNESS TO SUPPORT SPECIFIED WIRE TABLE 6.62B OF THE EROSION AND iD 3 7. MAINTAIN TREE PROTECTION FENCE THROUGHOUT DURATION OF - - FENCING AND FILTER FABRIC. a z PROJECT. - SEDIMENT CONTROL PLANNING AND DESIGN 8. FOR CONDITIONS WHERE PRACTICE APPLIES; PLANNING 8" MINIMUM COVER 4. TURN SILT FENCE UP SLOPE AT ENDS. MANUAL. CONSIDERATIONS ( HOWEVER FLOW SHALL NOT RUN PARALLEL OVER SKIRT * 5. ORANGE SAFETY FENCE IS REQUIRED AT BACK OF SILT FENCE SKIRT TO BE TRENCHED IN, AT (WITHIN 5 FT.) WHEN GRADING IS ADJACENT TO SWIM BUFFERS OR SYNTHETIC FILTER FABRIC SHOULD CONTAIN n - GRADE WITH THE FENCE) AND DESIGN CRITERIA. _ - MINIMUM, 8-INCHES VERTICALL WETLANDS (REFER TO SWIM BUFFER GUIDELINES). ULTRAVIOLET RAY INHIBITORS AND 9. END OF SILT FENCE NEEDS TO BE TURNED UPHILL. 6. WHEN SILT FENCE IS PLACED IN DUPLICATE AT STREAM AND STABILIZERS TO PROVIDE A MINIMUM OF 6 10. SEE N.C. STATE DENR PRACTICE & SPECIFICATION - - AND 4-INCHES HORIZONTALLY. WETLAND CROSSINGS, THE FENCING SHALL BE SPACED A MINIMUM MONTHS OF EXPECTED USABLE SEDIMENTS FENCE SECTION. FOR CONDITIONS WHERE PRACTICE APPLIES; PLANNING CONSIDERATIONS. OF 3' APART. CONSTRUCTION LIFE AT A TEMPERATURE 11. SEE N.C. STATE DENR PRACTICE &SPECIFICATION SIDE VIEW RANGE OF 0 TO 120' F. SEDIMENTS FENCE SECTION. (HOWEVER FLOW SHALL NOT RUN MAINTENANCE NOTES: PARALLEL WITH THE FENCE) 40" 1. FILTER BARRIERS SHALL BE INSPECTED AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS _ NEEDED SHALL BE MADE IMMEDIATELY. SIDE VIEW 2. SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR -T-�n---� TREE PROTECTION AREA _ TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER T n DO NOT ENTER - STILL IS NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. _ 40" __II 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN THE DEPOSITS 1 - I REACH 1-FOOT IN HEIGHT OF THE BARRIER. ANY SEDIMENT - DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS WARNING SIGN DETAIL TREE PROTECTION AREA REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING J oD MAINTENANCE: GRADE, PREPARED AND SEEDED. DO NOT ENTER 1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS a IMMEDIATELY. 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT WARNING SIGN DETAIL PROMPTLY. N.T.S. I I EC-091 TEMPORARY TREE PROTECTION FENCE SKIRT TO BE TRENCHED IN, AT MINIMUM, 8-INCHES VERTICALLY STEEL POST SET MAX II AND 4-INCHES HORIZONTALLY. APART MIN 2' INTO SOLID GROUND TEMPORARY SILT FENCE FOR HIGH HAZARD AREAS. REFER TO DETAIL EC-X. TEMPORARY SILT FENCE FOR SLOPE BORING PIT SLOPE ass ass- SPOIL PILE (EITHER OR BOTH SIDES) HIGH HAZARD AREAS. REFER TO DETAIL EC-X. ass N PIT T M SSF SILT FENCE FOR SILT FENCE FOR HIGH HIGH HAZARD AREAS HAZARD AREAS IBORING PIT I I RECEIVING I PIT STEEL POST - - - - - WOVEN WIRE FABRIC NO7E 1. CONTRACTOR TO PROVIDE SEDIMENT PITS AS NECESSARY. ALL PITS SHALL BE PROTECTED AS HARDWARE CLOTH WELL AGAINST SEDIMENTATION RUNOFF. 2. ALL SPOIL PILES TO BE PLACED WITHIN SILT FENCE AREA. FILTER OF SECTION VIEW 3. CHECK DAMS REQUIRED IN DOWNSTREAM DITCHES AT ALL CONSTRUCTION ENTRANCES. #57 WASHED STONE ? CONSTRUCTION SPECIFICATIONS: \\ 3' FILTER FABRIC APRON 1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFINS OR POLYESTER, ON GROUND WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFORMING TO THE 2;T REQUIREMENTS IN ASTM D 6461, WHICH IS SHOWN IN PART IN TABLE 6.62E OF THE EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. SYNTHETIC FILTER FABRIC SHOULD CONTAIN ULTRAVIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OF EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 TO 120' F. `SKIRT TO BE TRENCHED IN, AT BE LI 2.ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.25 LB/LINEAR FT MINIMUM STEEL WITH A BURY WIRE FENCE AND 4" MINIMUM, VERTICALLY MINIMUM LENGTH OF 5 FEET. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE HARDWARE CLOTH AND 4-INCHES HORIZONTALLY. FASTENING THE FABRIC. 3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OF 6 INCHES. MAINTENANCE 1. INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. MAINTENANCE: 2. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME 1. REMOVE SEDIMENT WHEN HALF OF INEFFECTIVE, REPLACE IT PROMPTLY. STONE OUTLET IS COVERED. 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE 2.REPLACE STONE AS NEEDED TO ENSURE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE DEWATERING. FENCE DURING CLEANOUT. 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. �EC-12I SILT FENCE OUTLET REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 03/27120 C 90%DESIGN - NOT FOR CONSTRUCTION 03/13/20 S 60%DESIGN - NOT FOR CONSTRUCTION OV07120 A 30%DESIGN - NOT FOR CONSTRUCTION 11NSN9 REVISIONS 3. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. 4. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. N.T.S. EC-1 01 TEMP. COMBO SILT/ TREE PROTECTION FENCE N.T.s. EC-1 11 TEMPORARY SUPER SILT FENCE N.T.S. R CROSS SECTION :LOTH PAVEMENT OR - IMPERVIOUS OR #57 SURFACE WASHED STONE I aI_\"q\YII �U�l NOTE$ 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACING A 2-FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NC DOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUNDCOVER. CONSTRUCTION SPECIFICATIONS: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACING A 2-FOTT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NCDOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADE ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUNDCOVER. MAINTENANCE, 1. INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (k INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. CONCRETE BLOCKS COMPOST SOCK OR SAND BAGS /- SIZED AS NEEDED CONCRETE BLOCKS OR SAND BAGS SIZED AS NEEDED AREA TO BE PROTECTED AREA TO BE PROTECTED WATER FLOW COMPOST SOCK WORK AREA SECTION PLAN NTS NTS NOTE 1. USE A MINIMUM 8 INCH DIAMETER COMPOST SOCK. 2. INSTALL COMPOST SOCK SO FLOW WILL NOT WASH AROUND SOCK. CONSTRUCTION SPECIFICATIONS: 1. COMPOST SOCKS SHOULD BE LOCATED AS SHOWN ON THE EROSION AND SEDIMENTATION CONTROL PLAN. 2. PRIOR TO INSTALLATION, CLEAR ALL OBSTRUCTIONS INCLUDING ROCKS, CLODS, AND OTHER DEBRIS GREATER THAN ONE INCHE THAT MAY INTERFERE WITH PROPER FUNCTION OF THE COMPOST SOCK. 3. FILL SOCK UNIFORMLY WITH COMPOST TO THE DESIRED LENGTH SUCH THAT LOGS DO NOT DEFORM. 4. HEAVY CONCRETE BLOCKS SHALL BE USED BEHIND THE SOCK TO HOLD IT IN PLACE DURING RUNOFF EVENTS. MAINTENANCE: 1. INSPECT COMPOST SOCKS WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL (1/2 INCH OR GREATER) REMOVE ACCUMULATED SEDIMENT AND ANY DEBRIS. 2. THE COMPOST SOCK MUST BE REPLACED IF CLOGGED OR TORN. 3. IF PONDING BECOMES EXCESSIVE, THE SOCK MAY NEED TO BE REPLACED WITH A LARGER DIAMETER OR A DIFFERENCE MEASURE. 4. THE SOCK NEEDS TO BE REINSTALLED IF UNDERMINED OR DISLODGED. 5. THE COMPOST SOCK SHALL BE INSPECTED UNTIL LAND DISTURBANCE IS COMPLETE AND THE AREA ABOVE THE MEASURE HAS BEEN PERMANENTLY STABILIZED. N.T.s. �EC-13I SILT FENCE LAYOUT AT PIT LOCATIONS N.T.S. J lEC-14I CLOTH AND GRAVEL YARD INLET PROTECTION N.T.S. ) �EC-15I COMPOST SOCK Venture IV Building, Suite 500 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com COUNTY DEPARTMENT OF UTILITIES JOHNSTON COUNTY 385 WEST TRANSMISSION IMPROVEMENTS DETAILS EROSION AND SEDIMENT CONTROL DETAILS PROJ. START DATE: 2019.NOV MCE PROJ. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROD. MGR. AJP N.T.S. SCALE D7 HORIZONTAL: 1"=40- DRAWING NUM VERTICAL: D REVISION STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\DETAILS\CD.01-003580141-J000385-DETAILS. DWG 03/27/2020 10:36:14 DAVID HAMMOND STEEL FENCE POST UPSTREAM END WEAVE STAPLES OF STORM DRAIN 9" MIN OF 2E STAKES ON OF 4 STAKES ON CASING OF WATTLE WATTLE TYPICAL NIMUM - - -� USE A MINIMUM THROUGH MESH _ ° UPSLOPE SIDE °8 7�-� J DOWNSLOPE SIDE II I �/ 9� ,� MATTING .:.:.: II - FILTER CLOTH ° WASHED STONE FILTER ACROSS - ii ii ii- - - - - - - - ----- STAPLES II I, ,I 1.5' STAPLES PIPE INLET III T 12" OF NCDOT #5 OR PROFILE VIEW DOWNSLOPE STAPLE INSTALLMENT SECTIONS HARDWARE I #57 WASHED STONE FLOW 1j CLOTH Ill UPSTREAM END t0FSTIORM DRAIN OVERFLOW CLASS GRIP-RAPX�FaQ OQSTAKES )5 PIPE DIAMETER t�(J < ��� � I� 1 FT 1 � jWATTLE ANGLE STAKES TO A v<Z I I� 1 II I I IWEDGE WATTLE .ONTO GROUND j ( ) ( � E , FILTER CLOTH C�� o��og p �g N 0 PLAN VIEW I JS ��� WASHED STONE GAD �6 �J ODMATTING U U U a A A MIN. 2 STAKES MINIMUM 4 FILTER ACROSSa INLET 4' TO 6' _ ON UPSLOPE STAKES ON - FRONT VIEW n DOWNSLOPEI,,,,_ CROSS SECTION VIEW ,T I I STAKE INSTALLMENT CROSS SECTION mm ALL PARTIALLY COMPLETED STORM DRAINS, UP TO 24 INCH PIPE SIZE, SHALL BE PROTECTED AT THE END OF EACH DAY IN ACCORDANCE WITH THESE DETAILS. SECTION VIEW ARDWARE CLOTH L = THE DISTANCE SUCH THAT POINTS A ANn R ARF OF FOIIAI FI FVATION DESIGN CRITERIA NOTES 1, THE DRAIIJAGE AREA IS LIMITED TO ONE HALF ACRE. 1. PLACE STONE TO THE LINE AND DIMENSION SHOWN IN THE 2. KEEP A MAXIMUM HEIGHT OF 2 FEET AT THE CENTER OF PLAN ON A FILTER FABRIC FOUNDATION. THE DAM. 2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES 3, KEEP THE CENTER OF THE CHECK DAM AT LEAST 9 BELOW NATURAL GROUND LEVEL WHERE THE DAM ABUTS THE INCHES LOWER THAN THE OUTER EDGES AT NATURAL CHANNEL BANK EC-16 STONE FILTER PIPE INLET PROTECTION N.T.S. GROUND ELEVATION, 3. EXTEND STONE AT LEAST 1.5 FEET BEYOND THE DITCH BAND: 4, KEEP THE SIDE SLOPES OF THE DAM AT 2:1 OR FLATTER TO KEEP WATER FROM CUTTING AROUND THE ENDS OF THE ENSURE THAT THE MAXIMUM SPACING BETWEEN DAMS CHECK DAM. PLACES THE TOE OF THE UPSTREAM DAM AT THE SAME 4. SET SPACING BETWEEN DAMS TO ASSURE THAT THE ELEVATION AS THE TOP OF THE DOWNSTREAM DAM. ELEVATION AT THE TOP OF THE LOWER DAM IS THE SAME AS 12 S. STABILIZE OUTFLOW AREAS ALONG THE CHANNEL TO THE TOE ELEVATION OF THE UPPER DAM. 2"-5" RESIST EROSION. 5. PROTECT THE CHANNEL AFTER THE LOWEST CHECK DAM 6. USE NCDOT CLASS B STONE AND LINE THE UPSTREAM SIDE FROM HEAVY FLOW THAT COULD CAUSE EROSION. OF THE DAM WITH NCDOT #5 OR #57 STONE. 6. MAKE SURE THAT THE CHANNEL REACH ABOVE THE MO-_- 7. KEY THE STONE INTO THE DI -CH BANKS AND EXTEND IT UPSTREAM IS STABLE. �O BEYOND THE ABUTMENTS A MINIMUM OF 1.5 FEET TO 7. ENSURE THAT OTHER AREAS OF THE CHANNEL, SUCH i+ AVOID WASHOUT FROM OVERFLOW AROUND THE DAM. CULVERT ENTRANCES BELOW THE CHECK DAMS, ARE NC �l 6 SUBJECT TO DAMAGE OR BLOCKAGE FROM DISPLACED 6" Q STONES, '• + + '� '" �' '� �' �' '" '" 8. DO NOT USE CHECK DAM IN INTERMITTENT OR PERENNIA.. . . . . . . W W W W STREAMS. CONSTRUCTION SPECIFICATIONS: 1. EVEN IF PROPERLY DESIGNED, IF NOT PROPERLY INSTALLED, RECP'S WILL PROBABLY NOT FUNCTION AS DESIRED. PROPER INSTALLATION IS IMPERATIVE. EVEN IF PROPERLY INSTALLED, IF NOT PROPERLY TIMED AND NOURISHED, VEGETATION WILL PROBABLY NOT GROW AS DESIRED. PROPER SEED/VEGETATION SELECTION IS ALSO IMPERATIVE. 2. GRADE THE SURFACE OF INSTALLATION AREAS SO THAT THE GROUND IS SMOOTH AND LOOSE. WHEN SEEDING PRIOR TO INSTALLATION, FOLLOWING THE STEPS FOR SEED BED PREPARATION, SOIL AMENDMENTS, AND SEEDING IN SURFACE STABILIZATION, 6.1. ALL GULLIES, RILLS, AND ANY OTHER DISTURBED AREAS MUST BE FINE GRADED PRIOR TO INSTALLATION. SPREAD SEED BEFORE RECP INSTALLATION. (IMPORTANT: REMOVE ALL LARGE ROCKS, DIRT CLODS, STUMPS, ROOTS, GRASS CLUMPS, TRASH, AND OTHER OBSTRUCTIONS FROM THE SOIL SURFACE TO ALLOW FOR DIRECT CONTACT BETWEEN SOIL SURFACE AND THE RECP.) 3. TERMINAL ANCHOR TRENCHES ARE REQUIRED AT RECP ENDS AND INTERMITTENT TRENCHES MUST BE CONSTRUCTED ACROSS CHANNELS AT 25-FOOT INTERVALS. TERMINAL ANCHOR TRENCHES SHOULD BE A MINIMUM OF 12 INCHES IN DEPTH AND 6 INCHES IN WIDTH, WHILE INTERMITTENT TRENCHES NEED BE ONLY 6 INCHES DEEP AND 6 INCHES WIDE. 4. INSTALLATION FOR SLOPES - PLACE THE RECPS 2-3 FEET OVER TOP OF THE SLOPE AND INTO AN EXCAVATED END TRENCH MEASURING APPROXIMATELY 12 INCHES DEEP BY 6 INCHES WIDE. PIN THE RECP AT 1 FOOT INTERVALS ALONG THE BOTTOM OF THE TRENCH, BACKFILL, AND COMPACT. UNROLL THE RECP DOWN (OR ALONG) THE SLOPE MAINTAINING DIRECT CONTACT BETWEEN THE SOIL AND RECP. OVERLAP ADJACENT ROLLS A MINIMUM OF 3 INCHES. PIN THE RECP TO THE GROUND USING STAPLES OR PINS IN A 3 FOOT CENTER -TO -CENTER PATTERN. LESS FREQUENT STAPLING/PINNING IS ACCEPTABLE ON MODERATE SLOPES. 5. INSTALLATION IN CHANNELS - EXCAVATE TERMINAL TRENCHES (12 INCHES DEEP AND 6 INCHES WIDE) ACROSS THE CHANNEL AT THE UPPER AND LOWER END OF THE UNED CHANNEL SECTIONS. AT 25-FOOT INTERVALS ALONG THE CHANNEL, ANCHOR THE RECP ACROSS THE CHANNEL EITHER IN 6 INCH BY 6 INCH TRENCHES OR BY INSTALLING TWO CLOSELY SPACED ROWS OF ANCHORS. EXCAVATE LONGITUDINAL TRENCHES 6 INCHES DEEP AND WIDE ALONG IC TO BURY OUTSIDE RECP EDGES. PLACE THE FIRST RECP IN THE CHANNEL EDGES ABOVE WATER LINE IN WHICH RY THE T TERMINAL TRENCH AND PINE IT AT 1 FOOT INTERVALS ALONG THE BOTTOM OF THE TRENCH. NOTE: THE RECP SHOULD BE PLACED UPSIDE DOWN IN THE TRENCH WITH THE ROLL ON THE DOWNSTREAM SIDE OF THE BENCH. 6. ONCE PINNED AND BACKFILLED, THE RECP IS DEPLOYED BY WRAPPING OVER THE TOP OF THE TRENCH AND UNROLLING UPSTREAM. IF THE CHANNEL IS WIDER THAN THE PROVIDED ROLLS, PLACE ENDS OF ADJACENT ROLLS IN THE TERMINAL TRENCH, OVERLAPPING THE ADJACENT ROLLS A MINIMUM OF 3 INCHES. PIN AT 1 FOOT INTERVALS, BACKFILL, AND COMPACT. UNROLL THE RECP IN THE UPSTREAM DIRECTION UNTIL REACHING THE FIRST INTERMITTENT TRENCH. FOLD THE RECP BACK OVER ITSELF, POSITIONING THE ROLL ON THE DOWNSTREAM SIDE OF THE TRENCH, AND ALLOWING THE MAT TO CONFORM TO THE TRENCH. 7. THEN PIN THE RECP (TWO LAYERS) TO THE BOTTOM OF THE TRENCH, BACKFILL, AND COMPACT. CONTINUE UP THE CHANNEL (WRAPPING OVER THE TOP OF THE INTERMITTENT TRENCH) REPEATING THIS STEP AT OTHER INTERMITTENT TRENCHES, UNTIL REACHING THE UPPER TERMINAL TRENCH. 8. AT THE UPPER TERMINAL TRENCH, ALLOW THE RECP TO CONFORM TO THE TRENCH, SECURE WITH PINES OR STAPLES, BACKFILL, COMPACT AND THEN BRING THE MAT BACK OVER THE TOP OF THE TRENCH AND ONTO THE EXISTING MAT (2 TO 3 FEET OVERLAP IN THE DOWNSTREAM DIRECTION), AND PIN AT 1 FOOT INTERVALS ACROSS THE RECP. WHEN STARTING INSTALLATION OF A NEW ROLL, BEGIN IN A TRENCH OR SHINGLE -LAP ENDS OF ROLLS A MINIMUM OF 1 FOOT WITH UPSTREAM RECP ON TOP TO PREVENT UPLIFTING. PLACE THE OUTSIDE EDGES OF THE RECP(S) IN LONGITUDINAL TRENCHES, PIN, BACKFILL, AND COMPACT. 9. ANCHORING DEVICES - 11 GAUGE, AT LEAST 6 INCHES LENGTH BY 1 INCH WIDTH STAPLES OR 12 INCH MINIMUM LENGTH WOODEN STAKES ARE RECOMMENDED FOR ANCHORING THE RECP TO THE GROUND. IN LOOSE SOIL CONDITIONS, THE USE OF STAPLE/STAKE LENGTHS GREATER THAN 6"/12" MAY BE NECESSARY TO PROPERLY SECURE THE RECPS. WHEN USING THE DOT SYSTEM-, STAPLES/STAKES SHOULD BE PLACED THROUGH EACH OF THE COLORED DOTS CORRESPONDING TO THE APPROPRIATE STAPLE PATTERN. 10. DRIVE STAPLES OR PINS SO THAT THE TOP OF THE STAPLE OR PIN IS FLUSH WITH THE GROUND SURFACE. ANCHOR EACH RECP EVERY 3 FEET ALONG ITS CENTER. LONGITUDINAL OVERLAPS MUST BE SUFFICIENT TO ACCOMMODATE A ROW OF ANCHORS AND UNIFORM ALONG THE ENTIRE LENGTH OF OVERLAP AND ANCHORED EVERY 3 FEET ALONG THE OVERLAP LENGTH. ROLL ENDS MAY BE SPLICED BY OVERLAPPING 1 FOOT (IN THE DIRECTION OF WATER FLOW), WITH THE UPSTREAM/UPSLOPE MAT PLACED ON TOP OF THE DOWNSTREAM/DOWNSLOP RECP. THIS OVERLAP SHOULD BE ANCHORED AT 1 FOOT SPACING ACROSS THE RECP. WHEN INSTALLING MULTIPLE WIDTH MATS HEAT SEAMED IN THE FACTORY, ALL FACTORY SEAMS AND FIELD OVERLAPS SHOULD BE SIMILARLY ANCHORED. MAINTENANCE 1. INSPECT ROLLED EROSION CONTROL PRODUCTS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAIN FALL EVENT REPAIR IMMEDIATELY. 2. GOOD CONTACT WITH THE GROUND MUST BE MAINTAINED, AND EROSION MUST NOT OCCUR BENEATH THE RECP. 3. ANY AREAS OF THE RECP THAT ARE DAMAGED OR NOT IN CLOSE CONTACT WITH THE GROUND SHALL BE REPAIRED AND STAPLED. 4. IF EROSION OCCURS DUE TO POORLY CONTROLLED DRAINAGE, THE PROBLEM SHALL BE FIXED AND THE ERODED AREA PROTECTED. 5. MONITOR AND REPAIR THE RECP AS NECESSARY UNTIL GROUND COVER IS ESTABLISHED. 6. STABILIZATION NOTE: STABILIZED GROUND COVER MUST BE ESTABLISHED WITHIN 7 DAYS IN AREAS WHERE SLOPES ARE STEEPER THAN 3:1 (SEE NPDES STABILIZATION TIMEFRAME SHEET D3) �EC-20I TEMPORARY SLOPE STABILIZATION REV.NO. DESCRIPTION DATE D ISSUED FOR PERMITTING- NOT FOR CONSTRUCTION 03/27/20 C 90%DESIGN - NOT FOR CONSTRUCTION 03/13/20 B 60%DESIGN - NOT FOR CONSTRUCTION 021071M A 30% DESIGN -NOT FOR CONSTRUCTION 11fl61119 REVISIONS EC-171 STONE CHECK DAM N.T.S. y WOODMAT TEMPORARY �l \ CROSSING REFER TO y DETAIL EC-13 WETLANBOU DARYD �1 y y y \ LIMITS OF DISTURBANCE (TYR) y y ssF y HIGH HAZARD SILT FENCE LO ��18" MIN (TYP.) ssF DOUBLE ROW OF 2sF y rE HIGH HAZARD 0 o z § g SILT FENCE DOUBLE ROW OF HIGH SILT FENCE W F REFER TO HAZARD << DETAIL EC-7) (REFER TO DETAIL EC-7) w C) m V) o a 0 wo 10, y PROPOSED y 10' ( PROPOSED SANITARY ) o y SEWER LINE w y y y SSF V SS F SSF y y y LIMITS OF y ` DISTURBANCE y SILT FENCE OUTLET TO (TYP) �v y y I BE PLACED ON THE I V y DOWNSTREAM SIDE OF CROSSING (TYP) (REFER TO DETAIL EC-8) NOTES 1. THE TOP 12" OF SOIL REMOVED FROM THE DISTURBED WETLAND AREA SHALL BE STOCKPILED ADJACENT TO THE WORK AREA AND REUSED FOR FINAL BACKFILL AT THE RESTORED GROUND SURFACE. 2. THE CONTRACTOR SHALL USE MATTING OR OTHER MEASURES NECESSARY FOR CROSSING WETLAND AREAS DURING EXCAVATION INSTALLATION AND BACKFILL OF THE SANITARY SEWER. 3. WETLAND AREAS SHALL BE RESTORED TO THE PRE -CONSTRUCTION GROUND ELEVATIONS AND REPLANTED IN ACCORDANCE WITH THE WETLAND SEEDING SCHEDULE, TECHNICAL SPECIFICATIONS AND THE APPROVED SECTION 404/401 NATIONWIDE PERMIT. CONSTRUCTION SPECIFICATIONS 1. KEEP CLEARING AND EXCAVATION OF THE WETLAND BED AND APPROACH SECTIONS TO A MINIMUM. 2. DIVERT ALL SURFACE WATER FROM THE CONSTRUCTION SITE ONTO UNDISTURBED AREAS ADJOINING THE WETLANDS. 3. KEEP WETLAND CROSSING AS PERPENDICULAR AS POSSIBLE TO THE FLOW. 4. STABILIZE ALL DISTURBED AREAS SUBJECT TO FLOWING WATER, INCLUDING PLANNED OVERFLOW AREAS, WITH RIPRAP OR OTHER SUITABLE MEANS IF DESIGN VELOCITY EXCEEDS THE ALLOWABLE FOR THE IN -PLACE SOIL. 5. REMOVE TEMPORARY WETLAND CROSSINGS IMMEDIATELY WHEN THEY ARE NO LONGER NEEDED. RESTORE THE WETLAND BED TO ITS ORIGINAL CROSS-SECTION, AND SMOOTH AND APPROPRIATELY STABILIZE ALL DISTURBED AREAS. 6. ANY IN -WETLAND SEDIMENT CONTROL MEASURES MUST BE REMOVED UPON STABILIZATION OF THE AREA. MAINTENANI 1. INSPECT TEMPORARY WETLAND CROSSINGS AFTER RUNOFF -PRODUCING RAINS TO CHECK FOR BLOCKAGE IN CHANNEL, EROSION OF ABUTMENTS, CHANNEL SCOUR, RIPRAP DISPLACEMENT, OR PIPING. MAKE ALL REPAIRS IMMEDIATELY TO PREVENT FURTHER DAMAGE TO THE INSTALLATION. IMPLEMENTATION SEQUENCE: SEDIMENT CONTROL MEASURES, PUMP -AROUND PRACTICES FOR WETLAND CROSSINGS, AND ASSOCIATED CONSTRUCTION SHALL BE COMPLETED IN THE FOLLOWING SEQUENCE (REFER TO DETAIL). 1. THE INTENT OF THIS CONSTRUCTION SEQUENCE IS TO PROVIDE THE CONTRACTOR WITH A GENERAL GUIDE FOR CONSTRUCTION PURPOSES. THIS SEQUENCE IS NOT INTENDED TO OUTLINE ALL CONSTRUCTION ACTIVITIES ON THIS PROJECT. 2. CONTRACTOR TO INSTALL HIGH HAZARD SILT FENCE AND SILT FENCE OUTLETS PER THE PLANS AND DETAILS. 3. CONTRACTOR IS TO MINIMIZE THE CLEARING AND EXCAVATION OF THE WETLAND BED, BANKS AND APPROACH SECTIONS TO A MINIMUM. 4. ONCE THE INSTALLATION OF THE SEWER LINE HAS BEEN INSTALLED AT A WETLAND CROSSING, THE CONTRACTOR IS TO RESTORE THE WETLAND BED TO ITS ORIGINAL CROSS-SECITON, AND SMOOTH AND APPROPRIATELY STABILIZE ALL DISTURBED AREAS. 5. THE CONTRACTOR IS TO SEED THE WETLAND IN ACCORDANCE WITH THE DETAILS SHOWN IN THESE PLANS (EC-4) AND THE PROJECT SPECIFICATIONS. Im V- DITCH SECTION VIEW MIN. 2 STAKES MINIMUM 4 ON UPSLOPE� STAKES ON DOWNSLOPE WATTLE-/ \ v`WS4 - MATTING MATTING TRAPEZOIDAL DITCH SECTION VIEW ISOMETRIC VIEW N 1. USE A MINIMUM 16 INCH DIAMETER EXCELSIOR WATTLE. 2. USE 24 INCH LONG WOODEN STAKES WITH A 2%2" NOMINAL CROSS SECTION. 3. INSTALL WATTLE(S) TO A HEIGHT ON SLOPE SO FLOW WILL NOT WASH AROUND WATTLE AND SCOUR SLOPES, OR AS DIRECTED. 4. INSTALL A MINIMUM OF TWO UPSLOPE STAKES AND FOUR DOWNSLOPE STAKES AT AN ANGLE TO WEDGE WATTLE TO GROUND AT BOTTOM. 5. PROVIDE STAPLES MADE OF 0.125 INCH DIAMETER STEEL WIRE FORMED INTO A U-SHAPE NOT LESS THAN 12 INCHES IN LENGTH. 6. INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. 7. AFTER INSTALLATION OF STAPLES, CHINK ANY GAPS BETWEEN WATTLE AND GROUND WITH MATTING. CONSTRUC11ON SPECIFICATIONS: 1. MATERIALS USED IN THE COMPOSITE SOCK MUST MEET THE SPECIFICATIONS OUTLINED ABOVE AND IN PRACTICE 6.18, COMPOST BLANKETS. 2. COMPOST SOCKS SHOULD BE LOCATED AS SHOWN ON THE EROSION AND SEDIMENTATION CONTROL PLAN. 3. PRIOR TO INSTALLATION, CLEAR ALL OBSTRUCTIONS INCLUDING ROCKS, CLODS, AND OTHER DEBRIS GREATER THAN ONE INCH THAT MAY INTERFERE WITH PROPER FUNCTION OF COMPOST SOCK. 4. COMPOST SOCKS SHOULD BE INSTALLED PARALLEL TO THE TOE OF A GRADED SLOPE, A MINIMUM OF 10 BEYOND THE TOE OF THE SLOPE. SOCKS LOCATED BELOW FLAT AREAS SHOULD BE LOCATED AT THE EDGE OF THE LAND -DISTURBANCE. THE ENDS OF THE SOCKS SHOULD BE TURNED SLIGHTLY UP SLOPE TO PREVENT RUNOFF FROM GOING AROUND THE END OF THE SOCKS. 5. FILL SOCK NETTING UNIFORMLY WITH COMPOST TO THE DESIRED LENGTH SUCH THAT LOGS DO NOT DEFORM. 6. OAK OR OTHER DURABLE HARDWOOD STAKES 2" X 2" IN CROSS SECTION SHOULD BE DRIVEN VERTICALLY PLUMB, THROUGH THE CENTER OF THE COMPOST SOCK. STAKES SHOULD BE PLACED AT A MAXIMUM INTERVAL OF 4 FEET, OR A MAXIMUM INTERVAL OF 8 FEET IF THE SOCK IS PLACED IN A 4 INCH TRENCH. SEE FIGURE 6.66B. THE STAKES SHOULD BE DRIVEN TO A MINIMUM DEPTH OF 12 INCHES, WITH A MINIMUM OF 3 INCHES PROTRUDING ABOVE THE COMPOST SOCK. 7. IN THE EVENT STAKING IS NOT POSSIBLE (I.E., WHEN SOCKS ARE USED ON PAVEMENT) HEAVY CONCRETE BLOCKS SHALL BE USED BEHIND THE SOCK TO HOLD IT IN PLACE DURING RUNOFF EVENTS. 8. IF THE COMPOST SOCK IS TO BE LEFT AS PART OF THE NATURAL LANDSCAPE, IT MAY BE SEEDED AT TIME OF INSTALLATION FOR ESTABLISHMENT OF PERMANENT VEGETATION USING THE SEEDING SPECIFICATION IN TEH EROSION AND SEDIMENTATION CONTROL PLAN. 9. COMPOST SOCKS ARE NOT TO BE USED IN PERENNIAL OR INTERMITTENT STREAMS. MAINTENANCE: 1. INSPECT COMPOST SOCKS WEEKLY AND AFTER EACH SIGNIFICANT RAINFALL EVEN (1/2 INCH OR GREATER). REMOVE ACCUMULATED SEDIMENT AND ANY DEBRIS. THE COMPOST SOCK MUST BE REPLACED IF CLOGGED OR TORN. IF PONDING BECOMES EXCESSIVE, THE SOCK MAY NEED TO BE REPLACED WITH A LARGER DIAMETER OR A DIFFERENT MEASURE. THE SOCK NEEDS TO BE REINSTALLED IF UNDERMINED OR DISLODGED. THE COMPOST SOCK SHALL BE INSPECTED UNTIL LAND DISTURBANCE IS COMPLETE AND THE AREA ABOVE THE MEASURE HAS BEEN PERMANENTLY STABILIZED. EC-181 STRAW WATTLE N.T.S. BRIDGEMAT SHALL BE INSTALLED TO HAVE A SOLID DECK SUCH THAT THERE IS NO SPACE BETWEEN PLANKS 6" LIP - MINIMUM MINIMUM 6" 1 SURFACE FLOW 25-FT MINIMUM U v SILT FENCE (TYPICAL) c o a 0 A 0 v ° 0 .� ANCHOR BRIDGEMAT i I TO A TREE OR OTHER PERMANENT OBJECT WITH SUFFICIENT STRENGTH, USING STEEL CHAIN OR CABLE. PERSPECTIVE VIEW AGGREGATE APPROACHWAY 2"-3" SURGE STONE OR RAILROAD BALLAST 1/4 SUPPORTED 1/4 SUPPORTED STREAM 7r _ SIDE VIEW STREAMBANK SURFACE FLOW DIVERSION • - • • . 1 • . /��f:%4 t �'§<r%gip �'i, <<'fi'�'%�i�, ei�%ei�� e'p��'%!%%.'%� P� i'•'�i��i!f'e%i �'�'i'e� � �oP �'��i '!��i'i!:i'<?i'<?i'<ei'<?i'<?'y� <<�f a<i<?<i'r:•'i'r f'i'<`i'<.'i'<o'i'<< -':'per'�r�'�?:<'e.•fe�%iC1•f,;�•f,;i'' f<i r�i,Upf'ri�, e<<f?<f$�rir$�riff�ip$!: rUi f4i?�r$?pf:<<f4pf<pff�ri!m _ •• ll,�•'ffI''•• fI `'ff•I''•• fI'••I I•'�•ff<�'ffI �'ffI'�• l,, • • • F. PRESS ENDS OF LINING 4 INCHES INTO THE SOIL AROUND STRUCTURES AND STAPLE SECURELY. EC-191 TEMPORARY STRAW WITH NET LINER INSTALLATION NOTES: 1. REFER TO "NORTH CAROLINA DIVISION OF FOREST RESOURCES" LITERATURE INSTALLATION MAINTENANCE GUIDELINES, & "NORTH CAROLINA FORESTRY BMP MANUAL-2006". 2. INSTALL WATER DIVERSION DEVICES (WATER BARS, TURNOUTS, BROAD -BASED DIPS, ETC.) ON BOTH SIDES OF THE MATS. 3. STABILIZE EXPOSED MINERAL SOIL WITH TREE TOPS OR BRUSH DURING MAT INSTALLATION, AND SEEDING/MULCH AFTER MAT REMOVAL. 4. INSTALL MATS TO CREATE A MINIMUM TEN FOOT BRIDGE WIDTH. 5. INCLUDE COARSE AGGREGATE ON THE APPROACHWAY FOR A MINIMUM OF 25 FEET AND SILT FENCE ALONG STREAMBANKS ADJACENT TO CROSSING FOR A MINIMUM OF 25 FEET. MAINTENANCE NOTES 1. KEEP MATS' SURFACE FREE OF MINERAL SOIL AND DEBRIS THAT COULD ENTER STREAM. 2. PERIODICALLY CHECK MAT HARDWARE; RETIGHTEN NUTS & CABLE CLAMPS AS NECESSARY TO MAINTAIN BRIDGE STRENGTH AND INTEGRITY. 3. IMMEDIATELY REMOVE ANY DEBRIS WHICH ENTERS THE STREAM AT THE CROSSING LOCATION. REMOVAL NOTES 1. CLEAN OFF BRIDGE SURFACE. 2. REMOVE MATS BY USING MAT CABLE LOOP OR SKIDDER GRAPPLE. 3. PERMANENTLY STABILIZE DISTURBED PORTIONS OF STREAMBANK AND APPROACH ROADS WITH PERENNIAL GRASSES/MULCH (OR WETLAND MIX WHEN APPLICABLE). 4. LEAVE APPROPRIATE WATER DIVERSION STRUCTURES IN PLACE ON BOTH SIDES OF STREAM. 5. RESTORE THE STREAM CHANNEL TO ITS ORIGINAL CROSS-SECTION, AND SMOOTH AND APPROPRIATELY STABILIZE ALL DISTURBED AREAS. N.T.s. �EC-211 TEMPORARY WETLAND CROSSING N.T.S. J EC-22 TIMBER MATTING FOR TEMP. WETLAND/ STREAM CROSSING N.T.S. •V •V d49224 � icy •..... 0. 10 venture IV Bulltling, Suite 5UU 1730 Varsity Drive Raleigh, North Carolina 27606 Phone: (919) 233-8091, Fax: (919) 233-8031 NC License# F-1222 www.mckimcreed.com JOHNSTON COUNTY 385 WEST JOHNSTON TRANSMISSION IMPROVEMENTS COUNTY DEPARTMENT OF UTILITIES DETAILS EROSION AND SEDIMENT CONTROL DETAILS PROJ. START DATE: 2019.NOV MCE PROD. # 00358-0141 DRAWN DWH DESIGNED WOH CHECKED AJP PROJ. MGR. AJP SCALE HORIZONTAL: 1"=4W VERTICAL: V.4. N.T.S. D8 MNG NUMBER D REVISION 'STATUS: ISSUED FOR PERMITTING NOT FOR CONSTRUCTION I:\00358\0141\WATER\80-DRAWINGS\DETAILS\CD.01-003580141-J000385-DETAILS. DWG 03/27/2020 10:36:16 DAVID HAMMOND