HomeMy WebLinkAboutWQ0032432_Regional Office Historical File 2016T. A Haney Consulting Engineers, PA February 26, 2016 [wat Mr. Tim HeimDivision of Water ResourcesF Non -Discharge Permitting Unit North Carolina Department of .Environment and Natural Resources << 2090 US Highway 70 ' Swannanoa, North Carolina 28778 RE:. Engineer's Certification (Partial) Valley River Sewer Pump Station Town of Andrews Cherokee County, North Carolina Permit No. WQ0032432 Dear Mr. Heim: Please find enclosed one (1) copy of the following for the above mentioned project: • Engineering Certification (Partial) • Design Calculations • Record Drawings The portion of this project which has been installed and completed consists of one (1) duplex sewer pump station and permanent emergency generator, 24 linear feet of 8-inch gravity sewer line and approximately 1,285 linear feet of 6-inch sewer force main. Due to changes in the planned use of the property, the sewer pump station and generator have been relocated to a site adjacent to the North Carolina Department of Transportation Right -of -Way for US 19/29/74 and the sewer force main was redirected on to the NCDOT Right -of -Way rather than across the property. No service connections were installed with this phase of construction. If you have any questions, or require additional information, do not hesitate to call. Sincerely, T. D. Haney Consulting Engineers, PA 4-7 T. Dean Haney, PE Enclosures. cc: Ed Burchins w/encl. 14-102/26febl6 69 Jenkins Valley load Alexander, North Carolina 28701 (826) 177-9219 Division of beater Resources ENGINEERING CERTIFICATION — POST CONSTRUCITION I VVatcr r)t t 3!it! R^CiOr??.! C}nGrations System Description: approximately 40 linear feet of 12-inch diameter gravity -sewer, a 180 duplex style sewage pumping station with audible and visual high water alarms, a permanently ins led emergency power generator with automatic transfer switch and telemetry and 13,050 line f et of 6- inch diameter force main Complete and submit this form to the Asheville regional office with the following: • One copy of the project record drawings (plan & profile views of sewer lines) of the wastewater collection system extension • supporting design calculations (selected pumps, system curve, operating point, available storage if portable generator(s) or storage greater than longest past three year outage reliability option selected) for any pump stations permitted as part of this project Changes to the project should be clearly identified on the record drawings or in written summary form. Permit modifications are re -uired for any changes resulting in non-compliance with this permit regulations or minimum design criteria This project shall not be considered complete nor allowed to operate until this Engineer's Certification and all required supporting documentation have been received by the Division. Therefore, it is highly recommended that this certification be sent in a manner that provides proof of receipt by the Division. ENGINEER'S CERTIFICATION _ [ Partial ❑ Final I, , as a duly registered Professional Engineer in the State of North Carolina, a olina, having been authorized to observe (❑ periodically, ❑ weekly, ❑ full time) the construction of the above referenced project for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance of this permit; 15A NCAC 2T; the Division of Water Quality's (Division) Gravity Sewer Minimum Design Criteria adopted February 12, 1996 as applicable; the Division's Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains adopted June 1, 2000 as applicable; and other supporting materials. North Carolina Professional Engineer's seal, signature, and date: .... ..... _............................................ SEND THIS FORM & SUPPORTING DOCUMENTATION WITH REQUIRED ATTACHMENTS TO THE FOLLOWING ADDRESS ROGER C. EDWARDS SURFACE WATER PROTECTION SUPERVISOR ASHEVILLE REGIONAL OFFICE 2090 US HIGHWAY 70 SWANNANOA, NC 28778 The Permittee is responsible for tracking all partial certifications up until a final certification is received. Any wastewater flow made tributary to the wastewater collection system extension prior to completion of this Engineer's Certification shall be considered a violation of the permit and shall subject the Permittee to appropriate enforcement actions. tOJECT NAME- ..tOJECT # PUMP STATION NAME - Proposed Flow = Pump Design = (2.5 X Average Flow) Valley River SPS 14-102 VR-PS#1 DiVfSloil^.i Yb<'a.af i�rJ ±r GICoS FEB 2 9 2016 Witer CJualiti, nlr,n�l Cr„ratiC' As -:: 62 gpm 180 gpm Distance From PS to High Point - 6,500 ft. Distance From High Point to 4-Inch Connection - 5,000 ft. Distance From 4-Inch Connection to Discharge - 4,500 ft. TOTAL DISTANCE 15,800 ft. Pumps Off Elev. - 1,600 ft Elev. @ High Point in Line - 1,750 ft Elev. @ 4-Inch Connection - 1,680 ft Elev. @ Discharge Point - 1,645 ft FRICTION LOSS CALCULATIONS FROM PUMP STATION TO HIGH POINT Q (Flow) _ L (Length) _ d (Diameter) _ C (Friction Coefficient) _ 180 gpm 6,500 ft 6 in 140 Hazen Williams Hf = 0.002083 X L X (100/C)^1.85 X (Q^1.85/d^4.8655) Q Hf He TDH 130 7 150 157 180 18 150 168 230 21 150 171 FRICTION LOSS CALCULATIONS FROM HIGH POINT TO 4-INCH CONNECTION Q (Flow) _ L (Length) _ d (Diameter) _ C (Friction Coefficient) _ 180 gpm 5,000 ft 6 in 140 Hazen Williams Hf = 0.002083 X L X (100/C)^1.85 X (QA1.85/dA4.8665) Q Hf He TDH 130 7 -70 -63 180 14 -70 -56 230 21 -70 -49 FRICTION LOSS CALCULATIONS FROM 4-INCH CONNECTION TO DISCHARGE * Final Pump Calculations Based on Future Replacement of Existing 4" SFM With 6" Pipe Q (Flow) = 180 gpm L (Length) _ 4,300 ft d (Diameter) = 6 in" C (Friction Coefficient) = 140 Hazen Williams Hf = 0.002083 X L X (100/C)"1.86 X (Q^1.85/dA4.8655) Q Hf He TDH 150 8 -35 -27 180 12 -35 -23 210 16 -35 -19 TOTAL HEAD LOSS DESIGN CALCULATIONS Total Head Loss = TDH From High Point to Discharge Point + TDH From Pump to High Point TDH From Pump to High Point - TDH From High Point to 4-Inch Connection - TDH From 4-Inch (6") Connection to Discharge Point - Design Flow = TDH = 168 ft. -56 ft. -23 ft. 180 gpm 168 ft IE- PUMP STATION NAME - Valley River SPS 14-102 VR-PS #1 Concrete Wt. = 150 Ibs/cf 4,000 Ibs/cy Earth Overburden Wt. = 45 Ibs/cf Water Wt. = 62.4 Ibs/cf (A.) Inside Diameter = 120 in. Volume per foot of wall height Inside Diameter = 10 ft. = Outside Dia. Area - Inside Dia. Area Wall Thickness = 10 in. = 28.35 cu.fL Outside Diameter = 140 in. Outside Diameter = 11.7 IL Weight of Manhole per foot of wall height = Volumn per foot of wall height X Concrete Wt. = 4252lbs/ft 100 Year Flood Elev. 1607.6 ft. Weight of Water per foot of wall height = Inside Dia. Area X Water Wt. 4898 Ibs/ft (B•) USE WITH STANDARD MANHOLE BASE SECTION Base Thickness = 0 in. Volume of base = Outside Dia. Area X Base Thickness Base Thickness = 0 ft. = 0.00 cu. ft. Weight of base = Volume of Base X Concrete Wt 0 lbs. (C-) USE WITH EXTENDED BASE SECTION Extended Base Area = 168.0 sq. ft. Volume of base = Extended Base Area X Base Thickness 210.00 cu. ft. Base Thickness = 15 in. Base Thickness = 1.26 fL Weight of base = Volume of Base X Concrete Wt. r = 31500lbs. Earth Overburden Area = Extended Base Area - Outside Dia. Area 61.15 sq. ft. Earth Overburden Weight per foot of depth = Earth Overburden Area X Earth Overburden Wt. = 2752lbs/ft Ground Elev. Top Wet Well InvL Elev. Depth Wet Well Wt. Riser Wt Base'., Earth Overburden Total Wt. Water Wt. Add. Concrete Wt. 1,609.00 11,610.00 1 1,597.00 1 13.00 1 55,277 31,500 33,023. 119,800 51,923 -67,877 ADDITIONAL CONCRETE BALLAST = -17.0 CY ' Use Section B with Standard Manhole Section or Section C with Extended Base Section " Add Earth Overburden only with Extended Base Manholes