Loading...
HomeMy WebLinkAboutWQ0030384_Application_20060612AT -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: WC3o030384 (to be completed by DWO) J. Owner. 1 a. Town of Aberdeen Full Legal Name (company, municipality, HOA, utility, etc.) Z Q I1 b. Bill Zell, Town Manager F„ Si --- Title- ---.__. --- _. _ _ - - . _ . -- _. __ .._ ..__ . ........_ ..---_..-- -- - . - 1 c. The legal entity who will own this system is. —❑ Individual ❑Federal ®Munici ali State/County ❑Private Partnershi ❑ Co oration ❑Others _E_. ty �! ___.____ ._ _._-... _ p _ �— __ �__peCnfZ_._.._.__.._. Q 1d. PO Box 785 - 115 N. Poplar Street le. Aberdeen LL Z- Mailing Address City -­_._.... ... _.. _ _.. "1f. NC 1g. 28315 0 State Zip Code h. 910-944-1115 il i. 910-944-7459 1 j. zelI11151nalltel.net t— (1 Telephone Facsimile E-mail V `2. - _.-.-__._..... _ _ _..__ .._ _ _- ------ ___. __.__ __._ . ......_ ............._. ....._...._.. _ _ __ . _.._ _.._ .... _. _ ......_ ._. Project (Facility) Information: J ,2a. ..._... ......... . ._...... ... ....... _......... ........... . . ....... .... ..... ................... _.......... ...... ...... __... __...... . ..... ......... Bonnie Brook Subdivision 2b. Moore 0. Brief Project Name (permit will refer to this name) County Where Project is Located Q -3. Contact Person: 3a. David T. Upchurch, P.E. Hobbs, Upchurch & Associates Name and Affiliation of Someone Who Can Answer Questions About this Application �3b.910-692-5616 _ _ ..-.---- _ _.------ _-_ .._ _____. _._ . _ _ __ _ - __-__ _ _.. _ ._._. ____.... _....... _... 3c. dupchurch@hobbsupchurch.com Phone Number E-mail 1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ®Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one 5`E ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Public Utility (Instruction 111) Z ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑Homeowner Assoc./Developer (Instruction IV) O ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) 1- ,3. Moore County Public Utilities I 4ik r)wnAr of WactPw=tPr TroafmPnf F=rilifv AAIWTFI T—af — W—f--for cam.,.,,, -rk;- 0_;__4 M+ PilHOMS, UPC' f[U2 C T & ASSOCLgq.S, PA B�'i' CONSULTING ENGINEER BnuKh Baekinl ud Traf comgoy P.O. BOX 1737, 300 S.W. BROAD STREET SOUTHERN PINES, NC 28388-tlLs3t (910)692-5616 Exactly Four hundred and no / 100 Dollars PAY TO THE ORDER N . C . DENR OF: NC DATE 5/31/2006 AJA59 AMOUNT $400.00 c 0 AFTER 90 DAYS u 6; AUTHORIZED SIGNATURE FTA 0?/03 - Rev 3 04/05 F,16T-TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 1 State of North Carolina DPIARDepartment of Environment and Natural Resources COPY JUN j Z 2006 Division of Water Quality FAST -TRACK APPLICATION for GRAVITE�EV,ERS, PUMP STATIONS, AND FORCE MAINS (Pressure sewers systems are not to be included as part of this application package) INSTRUCTIONS: Indicate that you have included/addressed the following list of required application package items by checking the space provided next to each applicable item. Failure to submit all required items will lead to your application being returned as incomplete. This form may be photocopied for use as an original. ® I. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless You respond NO to Item 13(12) II. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). Checks shall be dated within 90 days of application submittal. ❑ III. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2a) of this application. ❑ IV. Operational Agreements — Submit one original and two copies of a properly executed operational agreement if the sewer extension is permitted by a private applicant and will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be sold to another entity. If the applicant is a homeowners' association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF THE PROJECT WILL BE TURNED OVER TO A MUNICIPALITY, FORM DEV 02/03 IS REQUIRED. ❑ V. Flow Acceptance Letters — If the owner of the downstream sewers and/or WWTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and WWTF, if different. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. VI. Map — Submit an 8.5-inch by 11-inch COLOR copy of the portion of a 7.5-minute USGS Topographic Map along with this form. The map should identify the entire project area location as well as the closest downslope surface waters as clearly as possible. Each map portion must be labeled with the map name and number, the identified location of the sewer line and pump stations, and be of clear and reproducible quality. For instance, if the project involves 4 miles of interceptor sewer that traverses over or near several different waterbodies (or counties, basins, etc.), the map should have location ID's shown for each different waterbody (where the sewer line is within 100 feet of such waterbody - see Instruction VII). This location ID is self chosen and used to cross reference the location in Section C of the permit application. VII. Stream Classifications — Section C • If any portion of the project is within 100 feet of any down slope surface water, Section C must be completed for the pertinent sections. • If the entire project area is a minimum of 100 feet away from any down slope surface waters BUT there is a pump station involved where a history of power outage is to be used to provide adequate design storage instead of dual feed or permanent or portable generator, Section C must be completed to demonstrate that the closest down slope surface water is Class C (see 15A NCAC 2H .0219(h)(3)(D)). • Use the guidance document entitled, "Determining Watershed Classifications for Form FTA 02/03 (Fast -Track Sewer Systems)" available from http://h2o.enr.state.nc.us/peres or by contacting the appropriate regional office. CT A n� In FAST TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 2 ❑ Vill. Environmental Assessments — If this project is subject to an Environmental Assessment (EA) [15A NCAC 01C], this application can not be used. Send the project application on Form PSFMGSA 10/99 to the PERCS Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Applications can not be accepted until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. 5Q IX. Certifications — Section D The application must be certified by both the applicant and a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC 2H .0200, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. Certification by a PE who is unfamiliar with these documents is subject to NC Board referral. ❑ X. Downstream Sewer & Wastewater Treatment Plant Capacity The applicant has assured downstream pipe, pump station and treatment plant capacity. The addition of new sources of wastewater from this project has been evaluated along the route to the receiving treatment plant. The flow from this project will not cause capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving wastewater treatment plant. If the applicant is not the owner of the downstream sewer or receiving treatment plant, submittal of flow acceptance letters) indicates that owner has adequate capacity and will not violate G.S. 143-215.67(a). THE COMPLETED FTA 02/03 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $400 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office 2090 US Highway 70 Avery, Buncombe, Burke, Caldwell, Swannanoa, North Carolina 28778 Cherokee, Clay, Graham, Haywood, (828) 296-4500 Henderson, Jackson, Macon, Madison, (828) 299-7043 Fax McDowell, Mitchell, Polk, Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Anson, Bladen, Cumberland, Harnett, Fayetteville, North Carolina 28301 Hoke, Montgomery, Moore, Robeson, (910) 486-1541 Richmond, Sampson, Scotland (910) 486-0707 Fax Mooresville Regional Office 610 E. Center Avenue, Suite 301 Alexander, Cabarrus, Catawba, Mooresville, North Carolina 28115 Cleveland, Gaston, Iredell, Lincoln, (704) 663-1699 Mecklenburg, Rowan, Stanly, Union (704) 663-6040 Fax Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Franklin, Raleigh, North Carolina 27699-1628 Granville, Halifax, Johnston, Lee, Nash, (919) 571-4700 Northampton, Orange, Person, Vance, 919 571-4718 Fax Wake, Warren, Wilson Washington Regional Office 943 Washington Square Mall Beaufort, Bertie, Camden, Chowan, Washington, North Carolina 27889 Craven, Currituck, Dare, Gates, Greene, (252) 946-6481 Hertford, Hyde, Jones, Lenoir, Martin, (252) 975-3716 Fax Pamlico, Pasquotank, Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Duplin, Wilmington, North Carolina 28405 New Hanover, Onslow, Pender (910) 395-3900 (910) 350-2004 Fax Winston-Salem Regional Office 585 Waughtown Street Alamance, Alleghany, Ashe, Caswell, Winston-Salem, North Carolina 27107 Davidson, Davie, Forsyth, Guilford, (336) 771-4600 Rockingham, Randolph, Stokes, Surry, (336) 771-4631 Fax Watauga, Wilkes, Yadkin For more information, visit our web site at: http://h2o.enr.state.nc.us/peres/ PTA r»inz De *1 AA/AC FAST TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 I USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number - (to be completed by DWQ 1. Owner.• 1 a. Town of Aberdeen Full Legal Name (company, municipality, HOA, utility, etc.) Z 0 1 b. Bill Zell, Town Manager Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) - -- --- ...---- --- ..... _ . _.. _..._. __ ..... . ............................. - - _....-- 1 c. The legal entity who will own this system is ,., ❑ Individual ❑ Federal ® MuniClDality n State/County n Private Partnership n Corporation F1 Other lenerifv1- 0 1 d. PO Box 785 -115 N. Poplar Street 1 e. Aberdeen LIL Z............ Mailing Address City _------ _......_.._.._..... .... ............----...__.._................._....._...._.................._....._..._....._....__............................................................._...................................................._............................_...._..._....._.............._................_.......__......._..._.._........._.._._........_........__......_.._..__._..__._.._.....__._._.....---..._......_......_.... 1f. NC 1g. 28315 OF State Zip Code H 1 h. 910-944-1115 1 i. 910-944-7459 1 j. zell1115 alltel.net Q -- Telephone Facsimile E-mail -- ------ .._..--------------._.J.----- 0 42. Project (Facility) Information: a2a. Bonnie Brook Subdivision o 2b. More a Brief Project Name (permit will refer to this name) County Where Project is Located Q 3. Contact Person: Q Pa. David T. Upchurch, P.E. Hobbs Upchurch 8 Associates Name and Affiliation of Someone Who Can Answer Questions About this Application ----................ b. _._...- ---._....._................. _...._....---..-................._...._.......................... :......- ...... _....... __....._--..__._.._........ -- - ----- -- ----- -----......--.......... _._.. 910-692-5616 3c. du church hobbsu church.com Phone Number E-mail 1. Project is ® New ❑ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is ® Public (skip to Item B(3)) El Private (go to Item 2(a)) 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Public Utility (Instruction III) Z ❑Leasing units (lots, townhomes, etc. -skip to Item 8(3)) ❑ Homeowner Assoc./Developer (Instruction IV) 0 ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) Moore County Public Utilities Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project 4a. Moore County Wastewater Treatment Plant 4b. NPDES NC 0037508 0 Name of WWTF WWTF Permit No. LL 5a. Town of Aberdeen b. 8" JED Gravity c. X Z Owner of Downstream Sewer eceiving Sewer Size Force Main permit Number of Downstream Sewer (if known) F- S. The origin of this wastewater is (check all that apply): ® Residential Subdivision ❑ Car Wash tJ.l LU ❑ Apartments/Condominiums ❑ Institution 100 % Domestic/Commercial ❑ Mobile Home Park ❑ Hospital ❑ School El Church % Industrial ❑ Restaurant ❑ Nursing Home ElOffice ❑ Other s eci %Other (specify): (P fY)� 7. Volume of wastewater to be allocated for this particular project: 6,120 gallons per day *Do not include previously permitted allocations 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. i ❑ Rehabilitation or replacement of existing sewer with no new flow expected F rA minz _PP 2 nninc FAST TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 4 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item 13(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(1)(1-2) must be supported with actual water or wastewater use data in accordance with 15A NCAC 2H .0219(I)(3). _........... ......_............._._.__....... _.... ......................... -.............. _.... ........................ _... _....................... ...... ... _._...... ........................... ........... ................. _............. ................ _................. _........... -_._........... 17 single family homes @ 360 GPD = 6,120 GPD 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) 8 980 Gravity i -------- - ----- - - --.. _ _.... _ . _... _ _ _.. _ . - -....... ... ..-. ........ ...... .......... ...._...... _......... - ..... __... - ... --- - - - - __ .. ._._._ _....... -............ _.... _... ......... _.... _. . ............. LU Z Z Q a ENTER TOTAL LINE LENGTH IN MILES 0.18 ---- -- V111. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) O Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point ; (1- dual line feed; 2- permanent generator w/ATS; 3- Q plans for cross-reference) (MGD GPM TDH portable generator w/telemet , 4-wet well sto e ...---------- N/A Q IL Z...... ..... __..... _... _._........................ -- - -----.._....-------- ------.._.-. - ----- I- 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? W ® Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a d ` variance is requested. SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ® No ❑ N/A Sedimentation and Erosion Control Plan? -]Yes El No ®N/A Stormwater? ❑ Yes ❑ No ® N/A 14. Does this project involve aerial lines or siphons? Check if yes: ❑�— These lines..will.b.e...considered..high.priority..and..must.be..checked once..exerv..six-msanths._......... _ ....... 15. Does this project have gravity sewer lines designed at minimum slopes? Be aware that the Division will not accept installed lines more than 10% flatter than the minimum slope. Lines installed outside this tolerance should be corrected prior to submitting the final engineering certification.. FTA n,)mi 13— 11 AAJA, FAST TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality Z regional office (see instructions for addresses) OR indicate the following: O.. .._........ ........ :....... _ ....... .._... .... _ ............... ............... .. ........ ..._... .... A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope Qwaterbody; AND, V ® A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Vi Location ID on Map (self chosen - as shown on Name of1 Waterbody Stream Waterbody —map for cross-reference) Waterbody i County_ River Basin_: Index Classification O 1 .............. ... ...... _ Aberdeeen Creek Moore _ _. ._.... ; __.._... _ _... Lumber 14-2-11-(6) C . ... ... ..........................LU ............ _. __ .............. .... _ f ........ _ .. _._... .... _ ._. ..................... .... . ............. _. _ . ... .... .............. ........ . Submit the 8.5" x I " COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: l attest that this application for Bonnie Brook Subdivision has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. _... ........... _..._..._.._...._......................... ...._..._._.................. _._..... .. ----................. ........ ...... . 1 a. f 6`.7/p Signing Offici ignature Date ._.. _.. _ __ _ ._ ... _ U) .. _........ _ .. .......... _ . ._..... ......... ..._........... .............. ...... 2. Professional Engineers Certification: Z 0 1, David Upchurch, P.E. attest that this application for Habitat for Humanity Housing Project has been reviewed by me and H is accurate, complete and consistent with the information in the engineering plans, calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has Cai been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers _ adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force LL Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. L1J Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false () statement, representation, or certification in any application shall be guilty of a Class 2 misdemeanor which may include a Q fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. 2a. David Upchurch, P.E. Professional Engineer Name 2b. Hobbs, Upchurch & Associates P.A. Engineering Firm SEAL_ .__._ __ _ ..-___ _.__._ .__ _. i2c. _. _.__ _._-_._._.._ . ._....... , P.O. Box 1737 Mailing _.... Address 2d. Southern Pines 2e. NC 2f. 28388 city State Zip _... _ _. 2g 910-692 5616 2h 910-692-7342 2i. dupchurch@hobbsupchurch.com �P/"jbc, Telephone i Facsimile E-mail Seal, Signature & Date V'rA !Y1/A7 n-__ , n.in S - o f %•�� �- '_ -`z _. . '% � ;+ � � � 4r Nye � �'J ('J /rJ , 1 . `` 1 ter' 'ah ' • - .l• MP Af ii.. -- �.1. X / I ` • .�i' .a • •JI..%�..,�, • O I�' 1 • i s Air ..!� . f �,If -, _ 40 ok 77 40 j qop OA LV '- `•0 l� �- +/ rosy ,.+�✓yi'�. `. - r•rri .`S -7 41 .- _ • .•=�-� � —` `�' . . �`�! � / � 4 � 'f �.. ��, by f• � , -..J j 1p sda XXX 0 °2 c;opyngnt ku) iwi, maptecn, inc. TRANSMITTAL Hobbs, Upchurch 1,4 & Associates, P.A. Consulting Engineers P.O. Box 1737 300 S.W. Broad Street Southern Pines, North Carolina 28387 (910) 692-5616 FAX (910) 692-7342 TO: Trent Allen HUA PROJECT # AB0601 NCDENR Division of Water Quality HUA FILE NO. # AB0601 FROM: Tracy Skipper Hobbs, Upchurch & Associates, P.A. DATE: 6/21/06 RE: Utility Improvements to Serve Bonnie Brook Subdivision MESSAGE: Enclosed is the flow acceptance letter from Moore County as requested. Please feel free to contact this office for any additional information. h:1a60601 MWsewerltransmittal6-26-06.doc 06/23/2006 13:39 910-947-1992 MOORE CO. PUB. UTIL PAGE 02/03 CountY of Moore Tuber -W rks Depat-t-ment T. 0. 93ox 1g27 Carthage, Worth Carolina 28.?27 V OF Mood uticities j soad 'haste 910-947.6315 (TeCephone) 910-947-3637 (?elewhone) 910 ;947.19g2 (�'aCsrmi4e) 910-947-19.92 (FaCSimile) °Faornx�P� June23,2006 Mr. Tracy Skipper Hobbs, Upchurch 7 Associates, P.A. P 0 Box 1737 Southern Pines, NC 28388 Dear Mr. Skipper: RE: Flow Acceptance letter for Bonnie Brook Subdivision, Aberdeen, NC. The Moore County Water Pollution Control Facility, NPDES # NC 0037508, presently has sufficient capacity available to conditionally accept up to 6,120 gallons per day from the above referenced project. This project will be required to comply with. all specifications and requirements of the Town of Aberdeen, NC.. in addition all required fees must be paid to the Town of Aberdeen. Upon, completion of the referenced pro office with the following items: ject, the applicant's engineer is to provide our 1. Certification of Completion. 2. Complete set of As -Built drawings. If you have any questions or comments please call me at (910) 947.6315. 06/23/2006 13:39 910-947-1992 MOORE CO. PUB. UTIL PAGE 03/03 Flow Acceptance, Bonnie Brook June 1.3, 2006 Page 2 Sincerely, Cc: Mr. Delmo Frye, WWTP Superintendent Mr. Ricky Monroe, Public Works Director, 'Town of Aberdeen Mr. Giles Hopkins, Planning Director, Town of Aberdeen