GENERAL NOTES
1. ALL EXISTING STRUCTURES AND UTILITIES SHALL BE REMOVED AS NEEDED TO ALLOW NEW CONSTRUCTION. IN GENERAL,
FEATURES INDICATED IN BOLD ON THIS PLAN SHALL BE REMOVED.
2. ALL PAVEMENT OR CONCRETE TO BE REMOVED SHALL BE SAW CUT TO PROVIDE A STRAIGHT AND UNIFORM JOINT FOR NEW
PAVEMENT, SIDEWALK, OR CURB AND GUTTER, ETC. ANY EXISTING PAVEMENT, SIDEWALK, CURB AND GUTTER, ETC. THAT MUST
BE REMOVED TO ALLOW NEW CONSTRUCTION SHALL BE REMOVED AND REPAIRED PER THE SPECIFICATIONS AND DETAILS OR TO
MATCH PRE-CONS7RUC710N CONDITIONS (WHETHER OR NOT SHOWN ON THE DRAWINGS TO BE REMOVED).
J. ALL UTILITIES OR STRUCTURES NOT INDICATED FOR REMOVAL OR MODIFICATION ARE TO REMAIN AND BE PROTECTED FROM
DAMAGE.
4. ALL WASTE MATERIAL GENERATED FROM DEMOL17ION AC77WIlES SHALL BE DISPOSED OF OFF-SHEIN ACCORDANCE WITH ALL
APPLICABLE RULES AND REGULATIONS
5. EXISTING SITE BOUNDARY AND TOPOGRAPHIC SURVEY INFORMATION WAS TAKEN FROM SURVEY BY BRADY SURVEYING COMPANY
PA, PERFORMED MARCH 27, 2017. THESE PLANS DO NOT ASSUME ANY LIABILITY FOR ANY EXISTING INFORMATION BOTH SHOWN
AND NOT SHOWN ON THE SURVEY AND ANY CHANGES TO THE EXISTING CONDITIONS THAT MAY HAVE OCCURRED AFTER THE
SURVEY WAS ISSUED. CONTRACTOR SHALL VERIFY ALL EXISTING SITE CONDITIONS PRIOR TO CONSTRUCTION.
6. INSTALL TREE PROTECTION FENCING PRIOR TO BEGINNING CLEARING OPERATIONS CLEAR AND GRUB ALL AREAS AS SHOWN AND
REQUIRED TO PERMIT INSTALLATION OF NEW CONSTRUCTION PER SPECIFICATIONS AND DRAWINGS. EXISTING TREES, SHRUBS OR
OTHER LANDSCAPE MATERIAL WHICH WILL CONFLICT WITH NEW CONSTRUCTION SHALL BE REMOVED (WHETHER OR NOT SHOWN ON
THE DRAWINGS). ALL CONTRACTORS SHALL VISIT THE SITE AND OBSERVE EXISTING CONDITIONS PRIOR TO BIDDING.
7. TO MINIMIZE DAMAGE TO EXISTING TREES NEAR THE INTERIOR EDGE OF CLEARING LIMITS, THE CONTRACTOR SHALL CUT 2-FT
DEEP TRENCHES ALONG THE LIMITS OF DISTURBANCE, SO AS TO CUT, RATHER THAN TEAR ROOTS
& PRIOR TO DEMOLISHING EXISTING STRUCTURES, MAKE AN INSPECTION FOR ANY HAZARDOUS MATERIALS. CONTACT ARCHITECT
IMMEDIATELY IF ANY HAZARDOUS MATERIALS ARE DISCOVERED. CAP AND REMOVE UTILITY SERVICES, FUEL TANKS AND SEPTIC
SYSTEMS ALL WORK TO BE PERFORMED IN ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL REGULATIONS.
9. VERIFY ALL ILLUSTRATED UNDERGROUND ELEMENIS/UTILITIES. EXERCISE REASONABLE EFFORTS TO PROTECT ANY UNKNOWN
UNDERGROUND ELEMENTS/UTILITIES NOTIFY THE ARCHITECT IMMEDIATELY IF UNKNOWN ELEMENISAIlLI71ES ARE DISCOVERED
THAT WOULD NECESSITATE MODIFICATION TO THE PROPOSED DESIGN.
10. CONTACT UTILITY LOCATING SERVICE AT LEAST 48-HRS PRIOR TO EXCAVATION.
11. PROTECT ALL ADJACENT PROPERTIES, THE GENERAL PUBLIC AND ALL OF THE OWNER'S FACILITIES. SHOULD DAMAGES OCCUR,
REPAIR IMMEDIATELY AS DIRECTED BY THE ARCHITECT.
12 ALL CONSTRUCTION TO BE IN ACCORDANCE WITH ALL TOWN OF LEWISVILLE AND/OR NCDOT STANDARDS AND SPECIFICATIONS
13. ALL EXISTING VAULTS MANHOLES, STORM DRAIN STRUCTURES, CLEANOUTS ETC. SHALL BE ADJUSTED AS NEEDED TO MATCH
FINISH GRADE.
14. DEMOL1710N AND PATCHING OF PAVEMENT, SIDEWALK, CURB AND GUTTER AND OTHER EXISTING PAVED SURFACES IN ADDITION TO
THAT INDICATED ON THIS PLAN SHALL BE PERFORMED AS REQUIRED TO CONSTRUCT AND INSTALL NEW UTILITIES. ALL SUCH
DEMOLITION AND PATCHING SHALL BE INCLUDED IN THE BASE BID SCOPE OF WORK. SEE SHEET C07.07 FOR PAVEMENT REPAIR
DETAILS.
15. THIS SITE IS NOT LOCATED WITHIN SPECIAL FLOOD HAZARD AREAS AS DETERMINED BY FEMA AND DEPICTED ON F.I.R.M. MAP
3710588600J, DATED 11212009 AS BEING WITHIN ZONE "X-OTHER AREA".
16. NO WORK SHALL BE PERFORMED ON RIGHT-OF-WAYS OR ADJACENT PROPERTIES UN77L THE OWNER N077FIES CONTRACTOR IN
WRITING OF PROCUREMENT OF APPROPRIATE PERMITS, EASEMENTS, AGREEMENTS OR RIGHTS -OF -WAY.
3/ "IRON
\
�v Icu
"IR N �INI-EIP01,
28'\\����� \
/ I /e S6 1 \ \ EXISTIN L
c, J \ y� INV. 834.07 I \ \
�, \ T
2p F IRON \ J -� BENCHMARK -TOP OF OPERATING BOLT 821.29
\ _ 7_
W I 7058 BMFHTOPNUT
I �\ INV. 8278
�12"CONC. ���
ON IN 826.6003
IS1 NG WALL 8 —
Fi \—= v
o 836 / Q1 l �� \\�\\\ �_ \ XIS ING WALL
rn / / // �` �\_ _
w
I —
I 07)
_�
'402g'Eia, I I / l \SE�gc� \� -'; \i \ 573 gip" ' \ �\
72�53„ I / �p cn / O !� \ > I �' \�` \ \ �g EXISTING WALL
Tie E l / l D / o / T ) \ / I R `'�- \\ �� v -
I / / B54
3/„IRON / �� Os/�O
/// I / C �� � I I �! 7� �1 IRO ` — _-- (6 /�i J O = W _
I / / 7_ 0 RD R
474.
/ ��rx_-ft--EXtSTNG_W LLL�\ -- _
836 / /////'//// // // / / \ \ \_E!� 79
�B34-/'WOODED / �O
00
Jok
WOODED A
MATCHLINE AREA 4 ,
�B26
AREA 3804
22
322
B
AREA 4
--- ����/ // � — � •F — �-7' _ � /� jam`" �— jL —� '
/
CONSTRUCTION LIMI / / /
CO�UCTIOJIMITS // //
W
��// / /—
/
/ // // /// // // // // /// / o I• �/• /��\� 2�� j��—_� _ N89 '56 I By•\
// / —788��Z _ in �E �2'1RON
lo
802 \\\\ \\\�
804
806
� \ / �!/� / /7 / // / 808
810
Cp
812
--J
816
\\\_\\ \ \N'
818
90 \r\\\\\\\\\� 100 YEAR FLOODWAY
WOODED \ \ \ \ \ \\\\ \\ 500 YEAR FLOODWAY
822
\ cam \ I \
—
— — — —
_ \ \
826
828 \
/ J\
i
//
—
/// 830
\
LEGEND
STRUCTURESIUTILITIES TO BE REMOVED
STRUCTURES/UTTLITIES TO REMAIN
OVERHEAD
E ______
OVERHEAD ______
E
ELECTRICAL
ELECTRICAL
UNDERGROUND
UNDERGROUND
ELECTRICAL
ELECTRICAL
FIRE PROIEC71ON
------FP------
FIRE PR071=C71ON------FP
-----
GAS
------ G ------
GAS ------
G -----
SANITARY SEWER
------SS------
SANITARY SEWER ------SS
-----
TELEPHONE
------ T ------
TELEPHONE ------
T -----
UNDERGROUND
UNDERGROUND------UT-----
TELEPHONE
TELEPHONE
FIBER OPTIC
------FO------
FIBER OPTIC------FO
-----
WATER
------ W ------
WATER ------
W -----
FORCE MAIN
------FM------
FORCE MAIN ------FM
-----
STORM DRAIN
= _ _�i_�_ =
STORM DRAIN
INDIVIDUAL TREE
�
INDIVIDUAL TREE
TO REMAIN.
0
TO BE REMOVED.
LIGHT POLE
LP
LIGHT POLE
LP
pp
PP
UTILITY POLE
AV
UTILITY POLE
MANHOLE
OMH
MANHOLE
O MH
CLEAN OUT
0 CO
CLEAN OUT
O CO
DROP INLET,CATCH BASIN ❑ DI, CB
DROP INLET,CATCH BASIN
❑ DI, CB
FIRE HYDRANT
FH
FIRE HYDRANT
� FH
WATER VALVE
® WV
WATER VALVE
0 WV
CONS7R./CLEARING LIMITS
PAVEMENT, S/W, C&G
TO BE REMOVED.
TREE PR07EC71ON
FENCE
BUILDING/STRUCTURE
TO BE REMOVED BY
OWNER.
KEY NOTES
OTEMPORARY TREE PROTECTION FENCE, SEE DETAIL SHEET COZO1.
OB CLEAR AND GRUB, STRIP TOPSOIL WITHIN CONSTRUCTION LIMITS
OCONTRACTOR RESPONSIBLE FOR REMOVAL OF EXISTING FOOTING, AND UTILITIES IN THEIR ENTIRETY. CONTRACTOR TO
FIELD VERIFY EXISTING CONDITIONS PRIOR TO CONSTRUCTION.
D EXISTING UTILITY LINE/STRUCTURE TO BE REMOVED/RELOCATED BY LOCAL UTILITY COMPANY. LOCAL UTILITY
COMPANY SHALL DETERMINE THE LIMITS AND EXTENT OF REMOVAL/RELOCAiION OF U71LI71ES REQUIRED FOR NEW
CONSTRUCTION. COORDINATE SCHEDULE AND WORK WITH LOCAL UTILITY COMPANY AND ARCHITECT/OWNER.
OREMOVE FENCE.
OREMOVE SIGN AND POST. RELOCATE SIGN ON NEW POST AS INDICATED ON SITE STAKING PLAN.
OCAP AND ABANDON UTILITY IN ACCORDANCE WITH SPECIFICATIONS
OEXISTING STRUCTURE TO BE REMOVED.
OREMOVE EXISTING PAVING IN IT'S ENTIRETY.
OEXISTING WELL TO BE ABANDONED PER STATE AND COUNTY REQUIREMENTS.
NOTE: NO EXISTING WETLANDS ARE PRESENT ON THIS
SITE. DELINEATION REPORT COMPLETED BY PILOT
ENVIRONMENTAL, INC. CATHERINE L. CARSTON
(PROJECT MANAGER) & MICHAEL T. BRAME, PWS
(PRINCIPAL)
GRAPHIC SCALE
40 0 20 40 80
( IN FEET )
1 inch = 40 ft.
AREA 5
16C
Piedmont Leaf Lofts
404 East 4th Street,
Winston-Salem, NC 27101
Phone 336 722 6152 Fax 336 722 6192
www.mckissickassociates.com
Consultants:
Consultant Name Civil/Structural/MEP
Seal:
CLH DESIGN, P.A.
400 Regency Forest Drive
Suite 120
Cary, North Carolina 27518
Phone: (919)319-6716
Fax: (919)319-7516
LA: C-106, PE: C-1595
' >>���H IIIi�J►�fI
.•` O` \A CAR
.O
_ .
C.I
1
ISSUE LOG
Distribution Date No.
Client:
WINSTON-SALEM FORSYTH
COUNTY SCHOOLS
LEWISVILLE MIDDLE
SCHOOL
Drawing Title:
DEMOLITION PLAN
AREA 4 & AREA 5
Bid Documents
Issue Date
NOVEMBER 8, 2019
Project Number: Drawn by:
2017-8 RP/KL
Drawing Number
02004