HomeMy WebLinkAboutWQ0023150_Application_20031007Z 0 H Q O LL Z Z _0 F- Q c.i .I IL a. D ,RACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: , (to be completed by DWQ) 9. Owner: 1a. The Town of Southern Pines Full Legal Name (company, municipality, HOA, utility, etc.) 1b. Bobby B. Teague, P.E. Public works Director Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) 1 c. The legal entity who will own this system is: ❑ Individual ❑ Federal X Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify): 1d. 140 Memorial Park Court le. Southern Pines Street Address City 1f. North Carolina State 1 g. 28387 Zip Code 1 h. (910) 692-1983 1 i. (910) 692-1085 1 j. Telephone Facsimile 2. Project (Facility) Information: E-mail 2a. Highland Road Sewer Extension 2b. Moore Brief Project Name (permit will refer to this name) County Where Project is Located 3. Contact Person: 3a. Neal Smith, Professional Engineer Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (910) 695-8825 3c. nsmith@nsengineering.com Phone Number E-mail 1. Project is X New ❑ Modification (of an existing permit) If Modification, Permit No.: .For_._.. modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is X Public (skip to Item B(3)) ❑ Private (.qo to Item 2(a)) HIGHLAND MANAGEMENT LIMITED CORP. P.O. BOX 385 SOUTHERN PINES, NC 28388 WACHOVIA WACHOVIA BANK, NJ1. ACH R/T 053110400 66-1040/531 3859 9/29/2003 PAY TO THE NCDNR Division of Water Quality $ * *400.00 ORDER OF Four Hundred and 00/100************************************************************** ooUAM NCDNR Division of Water Quality MEMO �. ,atED SI�. 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected FTA 02/03 - Rev. 1 06/03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE I OF W A TF,4 State of North Carolina O� QG Department of Environment and Natural Resources Division of Water Quality o FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS (Pressure sewers systems are not to be included as part of this application package) INSTRUCTIONS: Indicate that you have included the following list of required application package items by checking the space provided next to each item. Failure to submit all required items will lead to your application being returned as incomplete or additional processing and review time. This form may be photocopied for use as an original. X I. Application Form - Submit one original and one copy of the completed and appropriately executed application form. Any changes to this form will result in the application being returned. The Division of Water Quality (Division) will only accept application packages that have been fully completed with all applicable items addressed. You do not need to submit detailed plans and specifications unless you respond NO to Item B(12). X II. Application Fee - Submit a check in the amount of $400 made payable to: North Carolina Department of Environment and Natural Resources (NCDENR). ❑ Ill. Certificates of Public Convenience and Necessity — If the application is being submitted in the name of a privately -owned public utility, submit two copies of the Certificate of Public Convenience and Necessity (CPCN) which demonstrates that the public utility is authorized to hold the utility franchise for the area to be served by the sewer extension. If a CPCN has not been issued, provide two copies of a letter from the North Carolina Utilities Commission's Public Staff that states that an application for a franchise has been received, that the service area is contiguous to an existing franchised area, and/or that franchise approval is expected. The project name in the CPCN or letter must match that provided in Item A(2a) of this application. ❑ IV. Operational Agreements — Submit one original and two copies of a properly executed operational agreement if the sewer extension is permitted by a private applicant and will be serving residential or commercial lots (e.g., houses, condominiums, townhomes, outparcels, etc.) that will be sold to another entity. If the applicant is a homeowners' association, use Form HOA 02/03. If the applicant is a developer, use Form DEV 02/03. EVEN IF THE PROJECT WILL BE TURNED OVER TO A MUNICIPALITY, FORM DEV 02/03 IS REQUIRED. X V. Flow Acceptance Letters — It the owner of the downstream sewers and/or WWTF is different from the applicant, submit two copies of a flow acceptance letter from the owner of the downstream sewers and WWTF, if different. Flow acceptance letters must contain the following minimum information: applicant and project name, amount of flow accepted, and name and permit number of the receiving sewers/WWTF. The flow acceptance must not expire prior to permit issuance and must be dated less than a year prior to the application date. Intergovernmental agreements or other contracts will not be accepted in lieu of a project -specific flow acceptance letter. X VI. Map — Submit an 8.5-inch by 11-inch COLOR copy of the portion of a 7.5-minute USGS Topographic Map along with this form. The map should identify the entire project area location as well as the closest downslope surface waters as clearly as possible. Each map portion must be labeled with the map name and number, the identified location of the sewer line and pump stations, and be of clear and reproducible quality. For instance, if the project involves 4 miles of interceptor sewer that traverses over or near several different waterbodies (or counties, basins, etc.), the map should have location ID's shown for each different waterbody (where the sewer line is within 100 feet of such waterbody - see Instruction VII). This location ID is self chosen and used to cross reference the location in Section C of the permit application. ❑ Vii. Stream Classifications — Section C • If any portion of the project is within 100 feet of any down slope surface water, Section C must be completed for the pertinent sections. • If the entire project area is a minimum of 100 feet away from any down slope surface waters BUT there is a pump station involved where a history of power outage is to be used to provide adequate design storage instead of dual feed or permanent or portable generator, Section C must be completed to demonstrate that the closest down slope surface water is Class C (see 15A NCAC 2H .0219(h)(3)(D)). • Use the guidance document entitled, "Determining Watershed Classifications for Form FTA 02/03 (Fast -Track Sewer Systems)" available from http://h2o.enr.state.nc.us/ndpu or by contacting the appropriate regional office. FTA 02/03 - Rev_ 1 06/03 FAST -TRACK APPLICATION for GRAVITY, SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 2 ❑ Vill. Environmental Assessments — If this project is subject to an Environmental Assessment (EA) [15A NCAC 01C .0500], this application can not be used. Send the project application on Form PSFMGSA 10/99 to the Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617. Applications can not be processed until a Finding of No Significant Impact (FONSI) or Environmental Impact Statement (EIS) has been issued. A copy is to be submitted with that permit application. X IX. Certifications — Section D The application must be certified by both the applicant and a North Carolina Registered Professional Engineer (PE). The applicant signature must match the signing official listed in Item A(1b). The PE should NOT certify the application if he/she is unfamiliar with 15A NCAC 2H .0200, the Gravity Sewer Minimum Design Criteria (most recent version) and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (most recent version), as applicable to the project. Certification by a PE who is unfamiliar with these documents is subject to NC Board referral. THE COMPLETED FTA 02/03 APPLICATION PACKAGE, INCLUDING ALL SUPPORTING DOCUMENTS AND $400 FEE, SHOULD BE SENT TO THE APPROPRIATE REGIONAL OFFICE REGIONAL OFFICE ADDRESS COUNTIES SERVED Asheville Regional Office Avery, Buncombe, Burke, Caldwell, 59 Woodfin Place Cherokee, Clay, Graham, Haywood, Asheville, North Carolina 28801 Henderson, Jackson, Macon, (828) 251-6208 Madison, McDowell, Mitchell, Polk, (828) 251-6452 Fax Rutherford, Swain, Transylvania, Yancey Fayetteville Regional Office 225 Green Street Suite 714 Fayetteville, North Carolina 28301 Anson, Bladen, Cumberland, Harnett, (910) 486-1541 Hoke, Montgomery, Moore, Robeson, (910) 486-0707 Fax Richmond, Sampson, Scotland Mooresville Regional Office 919 N Main Street Mooresville, North Carolina 28115 Alexander, Cabarrus, Catawba, (704) 663-1699 Cleveland, Gaston, Iredell, Lincoln, (704) 663-6040 Fax Mecklenburg, Rowan, Stanly, Union Raleigh Regional Office 1628 Mail Service Center Chatham, Durham, Edgecombe, Raleigh, North Carolina 27699-1628 Franklin, Granville, Halifax, Johnston, (919) 571-47 Lee, Nash, Northampton, Orange, (919) 571-4718 Fax Person, Vance, Wake, Warren, Wilson Washington Regional Office Beaufort, Bertie, Camden, Chowan, 943 Washington Square Mall Craven, Currituck, Dare, Gates, Washington, North Carolina 27889 Greene, Hertford, Hyde, Jones, (252) 946-6481 Lenoir, Martin, Pamlico, Pasquotank, (252) 975-3716 Fax Perquimans, Pitt, Tyrrell, Washington, Wayne Wilmington Regional Office 127 Cardinal Drive Extension Brunswick, Carteret, Columbus, Wilmington, North Carolina 28405 Duplin, New Hanover, Onslow, (910)395-3900 Pender (910) 350-2004 Fax Winston-Salem Regional Office 585 Waughtown Street Alamance, Alleghany, Ashe, Caswell, Winston-Salem, North Carolina 27107 Davidson, Davie, Forsyth, Guilford, (336) 771-4600 Rockingham, Randolph, Stokes, (336) 7714631 Fax Surry, Watauga, Wilkes, Yadkin For more information, visit our web site at: http://h2o.enr.state.nc.us/ndpu/ FTA 02/03 - Rev_ 1 06/03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 3 ......... ..... _... ........... ......... ............ .... ......... USE THE TAB KEY TO MOVE FROM FIELD TO FIELD! Application Number: , (to be completed by DWQ) ( 0p9 1. Owner: la. The Town of Southern Pines Full Legal Name (company, municipality, HOA, utility, etc.) Z 1b. Bobby B. Teague, P.E. Public works Director 0 Signing Official Name and Title (Please review 15A NCAC 2H .0206(b) for authorized signing officials!) 1c. The legal entity who will own this system is: ❑ Individual ❑ Federal X Municipality ❑ State/County ❑ Private Partnership ❑ Corporation ❑ Other (specify): 1d. 140 Memorial Park Court le. Southern Pines Street Address City Z 1f. North Carolina 1g. 28387 Z State Zip Code 1 h. (910) 692-1983 1 i. (910) 692-1085 1 j. ~ Telephone Facsimile E-mail C.) 2. Project (Facility) Information: J 2a. Highland Road Sewer Extension 2b. Moore a a Brief Project Name (permit will refer to this name) County Where Project is Located Q 3. Contact Person: Q 3a. Neal Smith, Professional Engineer Name and Affiliation of Someone Who Can Answer Questions About this Application 3b. (910) 695-8825 3c. nsmith@nsengineering.com Phone Number E-mail _. _ ......... 1. Project is X New ❑ Modification (of an existing permit) If Modification, Permit No.: For modifications, attach a separate sheet clearly explaining the reason for the modification (i.e. adding another phase, changing line size/length, etc.). Only include the modified information in this permit application - do not duplicate project information in B(7) and B(10-11) that has already been included in the original permit. 2. Owner is X Public (skip to Item B(3)) ❑ Private (go to Item 2(a)) ......... __ _.... .... . ..... 2a. If private, applicant will be: 2b. If sold, facilities owned by a (must choose one) Z H Q 3. ❑ Retaining Ownership (i.e. store, church, single office, etc.) or ❑ Public Utility (Instruction III) ❑ Leasing units (lots, townhomes, etc. - skip to Item B(3)) ❑ Homeowner Assoc./Developer (Instruction IV) ❑ Selling units (lots, townhomes, etc. - go to Item B(2b)) Moore County Public Utilities Owner of Wastewater Treatment Facility (WWTF) Treating Wastewater From This Project O 4a. Moore County Water Pollution Control Facility 4b. NC 0037508 LL Name of WWTF WWTF Permit No. 5a. The Town of Southern Pines 5b. 8" 5c. _Z Owner of Downstream Sewer Receiving Sewer Size Permit Number of Downstream Sewer (if known) 6. The origin of this wastewater is (check all that apply): X Residential Subdivision ❑ Car Wash W a ❑ Apartments/Condominiums ❑ Institution 100 %Domestic/Commercial ❑ Mobile Home Park ❑ Hospital ❑ School ❑ Church % Industrial ❑ Restaurant ❑ Nursing Home % Other s eci (p)' El Office El Other (specify): 7. Volume of wastewater to be permitted in this project: 1,440 gallons per day 8. If the permitted flow is zero, indicate why: ❑ Interceptor Line - Flow will be permitted is subsequent permits that connect to this line ❑ Flow has already been allocated in Permit No. ❑ Rehabilitation or replacement of existing sewer with no new flow expected V'rA M/A2 D- i nc/Al FAST -TRACK APPLICATION for GRAVITY SEWT;RS, PUMP STATIONS, AND FORCE MAINS PAGE 4 W D Z_ H Z O V v Z _O H Q O LL Z H W a ii 9. Provide the wastewater flow calculations used in determining the permitted flow in accordance with 15A NCAC 2H .0219(I) for Item 13(7) or the design flow for line or pump station sizing if zero flow in the space below. Values other than that in 15A NCAC 2H .0219(I)(1-2) must be approved prior to submittal of this application. Submit a separate request to the Division of Water Quality, Non -Discharge Permitting Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 in accordance with 15A NCAC 2H .0219(I)(3). 3 three/four bedroom houses at 480 gallons per day = 1,440 gallons per day 10. Summary of Sewer Lines to be Permitted (attach additional sheets if necessary) Size (inches) Length (feet) Gravity or Force Main (use the pull down menu) 8" 144' Gravity ENTER TOTAL LINE LENGTH IN MILES 0.027 miles 11. Summary of Pump Stations to be Permitted (attach additional sheets as necessary) Location ID Power Reliability Option (self chosen - as shown on Design Flow Operational Point (1- dual line feed; 2- permanent generator w/ATS; 3- plans for cross-reference) (MGD) GPM @ TDH portable generator w/telemetry; 4-wet well storage) 12. Does the sewer system comply with the Minimum Design Criteria for the Fast Track Permitting of Pump Stations and Force; Mains (latest version), the Gravity Sewer Minimum Design Criteria (latest version) and 15A NCAC 2H .0200 as applicable? X Yes ❑ No If no, please reference the pertinent minimum design criteria or regulation and indicate why a variance is requested: SUBMIT TWO COPIES OF PLANS, SPECIFICATIONS OR CALCULATIONS PERTINENT TO THE VARIANCE WITH YOUR APPLICATION 13. Have the following permits/certifications been submitted for approval? Wetland/Stream Crossings - General Permit or 401 Certification? ❑ Yes ❑ No X N/A Sedimentation and Erosion Control Plan? X Yes ❑ No ❑ N/A Stormwater? ❑ Yes ❑ No X N/A FTA 02/03 - Rev. 1 06/03 FAST -TRACK APPLICATION for GRAVITY SEWERS, PUMP STATIONS, AND FORCE MAINS PAGE 5 1. Use the Division's guidance document entitled, "DETERMINING STREAM CLASSIFICATIONS FOR FORM FTA 02/03 (FAST -TRACK SEWER SYSTEMS)" to collect and record the stream classification data below (attach additional sheets as necessary). This document is available from our web site or by contacting the appropriate Division of Water Quality Oregional office (see instructions for addresses) OR indicate the following: X A Stream Classification is not needed because all parts of the project are at least 100 feet away from any down slope Qwaterbody; AND, 0 X A Stream Classification is not needed because the design does not depend on wet well storage as a power reliability option for any pump station near a Class C down slope waterbody. Location ID on Map U) (self chosen - as shown on Name of Waterbody Stream Waterbody Jmap for cross-reference) Waterbody County River Basin Index Classification V Q W H .i, Submit the 8.5" x 11" COLOR topographic map as required in Instruction VI regardless of whether a classification is provided! 1. Applicant's Certification: 1, Bobby Teague, Public Works Director, attest that this application for Highland Road Sewer Extension has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. Note: In accordance with North Carolina General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, o certification in any application shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to $25 000 per violation. la. � ��� ��'oZ—U-j Signing Official Signature Date 2. Professional Engineer's Certification: Z I, Neal Smith, PE attest that this application for Highland Road Sewer Extension has been reviewed by me and is accurate, complete and consistent with the information in the engineering plans, calculations, and H all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the Q proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteriaz V for Gravity Sewers adopted February 12, 1996, and the Minimum Design Criteria for the Fast -Track Permitting of Pump 1L Stations and Force Mains adopted June 1, 2000 and the watershed classification in accordance with Division guidance. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with LU the proposed design. Note: In accordance with NC General Statutes 143-215.6A and 143-215.6B, any person who L) knowingly makes any false statement, representation, or certification in any application shall be guilty of a CI 2 misdemeanor which may include a fine not to exceed $10, 000 as well as civil penalties up to 25, 000 p r olati 2a. Neal Smith, PE os Professional Engineer Name' �� •' �� ' y� '., 2b. Neal Smith Engineering, Inc. Engineering Firm 2c. 575 SE Broad Street, Suite 11 Address 2d. Southern Pines City 2e. NC 2f. 28387 State Zip 2g. 910-695-8825 2h. 910-695-8835 2i. nsmith@nsengineering.com Telephone Facsimile E-mail -- H AL = 19311 2FN�IN1� Seal, Signature & Date FTA 02/03 - Rev. 1 06/03 y := rev • ,.: _ fit' � `-�' C' ''!- .� I ` �,,r J J' ti r'r�k�` � •y � � �' �!� i _ef -~ t�l �' `� �j• .. � -; Ir � ' d• J f �%, ,•�\�./•. 1•' •l j' ` G 1'.d.' i� .�, QO IL Ur. lk _'F!�•c--- ,v �i'�'s. rt��' 8' ' "1 f / r-'l-'}-, I , l � ._C.i 4-s-^_ �. \4 �Lr �'1 ( r �• �,t r�rr A it+s� I rJrl* �.J :•\ t y' �/ 1 '\ r%ti`, i-�A/� ram.! '1 11� 5�!�i •5�/lJ��/s'y4� .1 i t �%% '�1� '/'r �--�... s � // � it Jr L- _�,. I Y- .'r rii h � t-''.'--�- r; ryl,,�i � �,b �}� � J• �' , �-.h�� � �` '� (. � r •�+f - �� � `�' KT} , i � _ ,� -_r i : s � _ f - i t � I � , q • S .�_ / / \ - J / i t �_.j a . '`\ ti j �+r I�.,; �,L%�•i \ � _ .L�-�� ``r'�.,-4-' 'ry' A '_y."' ��'"` _ _ -•' -./ I� !s i t, _�t S C-r•f�____ G..— t +„ 1 11� f I ' 4�' � :•' 1�+ 'l' �j'� ���.�,r,��,� `� ' ,.�� j l', t ee�� :�`�'� ` Fl( . s w- ' i.-.'J r� i..._ r.t" . ts'-. ` • y?a r- i r , + �Z ��` \�� `._.r �� 1 ' �,�•' 1V•�r'�• w,r '_! iY-. r :-.: /;�% y � � '� tf y � �'11 ■, ; 14. 1+,� �;-'��� '•� �.- :i : =rs=•. - �`� ?-.-`��-��ti�,,,, • � � fry—g4�=-�' �,. "a •r-r / r i l• fIr .� �x- i ._r"--- , vs, `` `_ F i y F�,�_� r j� + �' t ` \ \. -ram , 'L .� \ .ir . � � ( �. . , J , I � '. , f �rr , {',•, ` _, fJ / , f ' � .._i�ti` 14� - / r ,�1 i-�, i t ,`i r K�' _r '� r � r• 4 5 i t � '��'�� � �/�� ♦ ... J.. �%. _•3. (Y.-v-� /f - - r!. - .fir G._t,'� . ,r� � .yr ?�r I� �'-� � y,>' i,� _..,•'�� '1 ��s � f' � / �. r l�r���) � +i`t V�J` J� - ` ` � ?_ 4 �-r .. 1 y + R; f ; �'`'" _ ''!"ate' i ���` 1 t i rr'/ r�.lt„ '` // 1J% �^'. ••�._ .��_ . -�'a 0 0.3 0.6 0.9 1.2 1.5 km ITIIv 0 0.2 0.4 0.6 0.8 1 mi Map center is UTM 17 646386E 3891025N (NAD27) Southern Pines quadrangle Projection is UTM Zone 17 NAD83 Datum MN=-g • 98 9/25/03 TRANSMITTAL TO: ALAN W KLIMEK, P.E. DIRECTOR, DIVISION OF WATER QUALITY FROM: BOBBY TEAGUE, P.E. TOWN OF SOUTHERN PINES SUBJECT: FAST TRACK APPLICATION DATE: 10/3/2003 CC: Dear Mr. Klimek: Enclosed please find a "Fast -Track Application" for "Highland Road Sewer Extension" in Southern Pines, North Carolina. Tw f 0�#outhpern n '.?l it11 F TM AW S.A Ai � b. emk� 140 MEMORIAL PARK COURT — SOUTHERN PINES, NC — 28387 Department of Public Utilities P.O. Box 1927 Carthage, NC 28327 upaunty a/ (P'Aaaxe October 1, 2003 Mr. Tom Wanko Neal Smith Engineering, Inc 575 SE Broad St. -Suite 11 Southern Pines, NC 28387 Dennis L. Brobst, Director Telephone: (910) 947-6315 Facsimile: (910) 947-1992 E-mail: dbrobst@co.moore.nc.us 1.1 Re: Flow Acceptance Letter for sanitary sewer improvements to serve the Highland Road sewer extension project, NSE job # 0309342 Dear Tom: The Moore County Water Pollution Control Facility, permit# NC 0037508, presently has sufficient capacity available to conditionally accept up to 1,440 GPD from the above referenced project. The project will be required to comply with all specifications and requirements of the Town of Southern Pines, NC and pay all required fees. Upon completion of the referenced project, the applicant's engineer is to provide our office with the following items: 1. Certification of completion. 2. Complete set of As -built drawings. If you have any questions or comments please call me at (910) 947-6315. Sincerely, MOORE COUNTY PUBLIC UTILITIES vid C. Dave rt Engineering oject Technician y90 'Town of Southern Pines Z a _ Public Works Department 140 MEMORIAL PARK CT. - SOUTHERN PINES, NORTH CAROLINA 28387 March 20, 2001 Ms. Kristin E. Miquez, Environmental Technician DCNENR, Non -Discharge Permitting Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Dear Ms. Miquez: Please accept this letter as documentation that Public Works Director, Bobby B. Teague is a duly authorized employee delegated to sign non -discharge permit applications for the Town of Southern Pines. Respectfully �g,wnKy So ner PHONE:910-692-1983 - FAX:910-692-1085