HomeMy WebLinkAboutWQ0032228_Application (FTSE)_20200511Permit Number WQ0032228
Program Category
Non -discharge
Permit Type
Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions
Primary Reviewer
dean.hunkele
Coastal SWRule
Permitted Flow
57.720
Facility
Central Files: APS _ SWP -
5/7/2020
Permit Tracking Slip
Status
Project Type
In review
Major modification
Version
Permit Classification
B
Individual
Permit Contact Affiliation
Facility Name Major/Minor Region
Stanbury Creek Development Sewer Minor Wilmington
Location Address County
Brunswick
Facility Contact Affiliation
Owner
Owner Name
Owner Type
Brunswick County
Government - County
Owner Affiliation
John Nichols
PE
PO Box 249
Dates/Events
Bolivia NC 2842202•
Scheduled
Ong Issue App Received Draft Initiated Issuance
10/12/2007 5/1/2020
Reaulated Activities
Apartment complex
Condominium
Subdivision
Wastew
NORMS & TUNSTALL
CONSULTING ENGINEERS P.C.
2602 Iron Gate Dr., Suite 102
Wilmington, NC 28412
(910)343-9653
(910)343-9604 Fax
John S. Tunstall, P.E.
T.Jason Clark, P.E.
April 28, 2020
Dean Hunkele
NCDEQ — Water Quality Division
Wilmington Regional Office
127 Cardinal Drive Extension
Wilmington, NC 28405
Re: Gravity Sewer Extension Fast -Track Permit Application
Project: Stanbury Creek Off -Site Forcemain
N&T Project No.19075
Dear Mr. Hunkele,
1429 Ash -Little River Road
Ash, NC 28420
(910) 287-5900
(910) 287-5902 Fax
J. Phillip Norris, P.E.
Thomas J. Scheetz, E.I.
MAY 0 1 2020
t ,1
Enclosed please find a check in the amount of $480.00 (Norris Ck. No. 1606) for the processing
fee and the following copies:
1. Approval letter from Brunswick County Engineering
2. Sewer Narrative
3. Application (FTA 04-16)
4. Flow Tracking / Acceptance Form (FTSE 10-18) from Brunswick County Engineering
5. Two (2) 8 t/z x 11 color USGS Topographic Maps
6. Two (2) site plans (ledger size)
Please review this information for approval and contact us with any questions or comments you
may have. Thank you for your assistance on this project.
Sincerely,
NORRIS & TUNSTALL
CONSULTING ENGINEERS, P.C.
J. hillip Norris, P.E.
J /ttw
075 04-28-20 s ft- swr-Itr
Enclosures
cc: Wayne Smith
NCBELS License C-3641
Division of Water Resources
State of North Carolina
Department of Environmental Quality
i�T�gO�s Division of Water Resources
15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION
FTA 04-16 & SUPPORTING DOCUMENTATION
Application Number:
(to be completed by DWR)
All items must be completed or the application will be returned
1. APPLICANT INFORMATION:
1. Applicant's name: Brunswick County (company, municipality, BOA, utility, etc.)
2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility
❑ Federal ® State/County ❑ Municipal ❑ Other
3. Signature authority's name: William L. Pinnix, P.E. per 15A NCAC 02T .0106(b)
Title: Director of Engineering
4. Applicant's mailing address: P.O. Box 249
City: Bolivia State: NC Zip: 28422-
5. Applicant's contact information:
Phone number: 910 253-2403 Email Address: william.pinnix c@brunswickcountync.gov
II. PROJECT INFORMATION:
1. Project name: Stanbury Creek Off -Site Forcemain
2. Application/Project status: ® Pro w Permit) LyExisting Permit/Project WaQ
If a modification, provide the existing permit number: WQOON/A and issued date: N/A
If new construction but part of a master plan, provide the existing permit number: W0000
3. County where project is located: Brunswick
4. Approximate Coordinates (Decimal Degrees): Latitude: 33 93' Longitude: -78 23.
5. Parcel ID (if applicable): N/A
(or Parcel ID to closest downstream sewer)
❑I. CONSULTANT INFORMATION:
1. Professional Engineer: J. Phillip Norris, P.E. License Number: 11966
Firm: Norris & Tunstall Consulting Engineers, P.C.
Mailing address: 1429 Ash -Little River Road NW
City: Ash State: NC Zip: 28420-
Phone number: (910) 287-5900 Email Address: pnorrisnntengineers.com
IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION:
1. Facility Name: Permit Number:
Owner Name: Brunswick County
V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF):
1. Permit Number(s): WQ 003 7o?Q MGb Downstream (Receiving) Sewer Size: 6 inch
System Wide Collection System Permit Number(s) (if applicable): WOCS 0028#
OwnerName(s): 332VnCVM
FORM: FTA 04-16 Page 1 of 5
VI. GENERAL REQUIREMENTS
1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached?
❑ Yes ❑No ®N/A
2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached?
❑ Yes ❑No ®N/A
3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached?
❑ Yes ❑No ®N/A
4. Origin of wastewater: (check all that apply):
® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash
❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels
❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse
❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash
❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment)
5. Nature of wastewater: 100 % Domestic/Commercial % Commercial
% Industrial (See 15A NCAC 02T .0103(20))
"Is there a Pretreatment Program in effect? ❑ Yes ❑ No
6. Hasa flow reduction been approved under 15A NCAC 02T .0114(P)? ®Yes ❑ No
➢ If yes, provide a copV of flow reduction approval letter
7. Summarize wastewater generated by project: N A
Establishment Type (see 02T.0114(f))
Daily Design Flow a,b
No. of Units
Flow
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
gal/
GPD
Total
GPD
a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per
dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas;
and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined
in G.S. 42A-4).
b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be
determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data.
8. Wastewater generated by project: 0 GPD (per 15A NCAC 02T .0114)
➢ Do not include future flows or previously permitted allocations
If permitted flow is zero, indicate why:
❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line
® Flow has already been allocated in Permit Number: W00032228
❑ Rehabilitation or replacement of existing sewer with no new flow expected
❑ Other (Explain):
FORM: FTA 04-16 Page 2 of 5
VIL GRAVITY SEWER DESIGN CRITERIA (If
1. Summarize gravity sewer to be permitted:
Size (inches)
- 02T .0305 & MDC (Gravity Sewers):
/'
Length (feet) Material
➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria
➢ Section III contains information related to minimum slopes for gravity sewer(s)
➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC
VIIL PUMP STATION DESIGN CRITERIA (If Applicable)-02T.0305 & MDC (Pump Stations/Force Mains):
COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT
1. Pump station number or name: SEE WO 0032228 Stanbury Creek for Pump Station
2. Approximate Coordinates (Decimal Degrees): Latitude: 33 93' Longitude: -78 23.
3. Design flow of the pump station: .0577 millions gallons per day (firm capacity)
4. Operational point(s) of the pump(s): 336 gallons per minute at 75 feet total dynamic head (TDH)
5. Summarize the force main to be permitted (for this Pump Station):
Size (inches)
Length (feet)
Material
8
11,922
PVC
HDPE
8
500
6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1):
(nRtq CA00)
(SpR ci)
® Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B).*
➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day
➢ Must be permanent to facility
Or if the pump station has an average daily flow less than 15,000 gallons per day:
❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T
.0305(h)(1)(C)
or
❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C):
➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement)
and is compatible with the station.
➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage
capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided
in the case of a multiple station power outage.
FORM: FTA 04-16 Page 3 of 5
IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T.0305(f)):
1. Does the project comply with all separations found in 15A NCAC 02T.0305(f) & (g)
➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems:
❑ Yes ❑ No
Setback Parameter*
Separation Required
Storm sewers and other utilities not listed below (vertical)
24 inches
Water mains vertical -water over sewer including in benched trenches
18 inches
Water mains horizontal
10 feet
Reclaimed water lines vertical - reclaimed over sewer
18 inches
Reclaimed water lines horizontal - reclaimed over sewer
2 feet
**Any private or public water supply source, including any wells, WS-I waters of Class I or
Class 11 impounded reservoirs used as a source of drinking water
100 feet
**Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal
high water or tide elevation and wetlands see item IX.2
50 feet
**Any other stream, lake, impoundment, or ground water lowering and surface drainage
ditches
10 feet
Any building foundation
5 feet
Any basement
10 feet
Top slope of embankment or cuts of 2 feet or more vertical height
10 feet
Drainage systems and interceptor drains
5 feet
Any swimming pools
10 feet
Final earth grade vertical
36 inches
➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved.
➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage
➢ If noncompliance with 02T.0305(f) or (g). see Section X of this application
2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes ❑ No ❑ N/A
➢ See the Division's draft separation requirements for situations where separation cannot be meet
➢ No variance is required if the alternative design criteria specified is utilized in design and construction
➢ As built documents should reference the location of areas effected
3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A
➢ This would include Trout Buffered Streams per 15A NCAC 213.0202
4. Does the project require coverage/authorization under a 404 Nationwide or ® Yes ❑ No
individual pennits or 401 Water Quality Certifications?
➢ Information can be obtained from the 401 & Buffer Permitting Branch
5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ® Yes ❑ No
Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have
been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and
sedimentation control plans, stormwater management plans, etc.).
6. Does this project include any sewer collection lines that are deemed "high -priority?"
Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer
positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer.
❑ Yes ®No ❑ N/A
➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location).
High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections
documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit.
FORM: FTA 04-16 Page 4 of 5
X. CERTIFICATIONS:
1. Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations
and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable?
104/ Mf
If No, complete and submit the Variance/Altemative Design Request application (VADC 10-14) and supporting documents for
review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents.
Professional Engineer's Certification:
" Q w [ 5 attest that this application for
(Prof sional Engineer' ame om A :cation Item JILL)
LLN �« A a� s� n
has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications,
engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best
of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer
Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting
of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this
submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and
have judged it to be consistent with the proposed design.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation.
A
n for
has been reviewed by the and is accurate and complete to the best of my knowledge. I understand that if all required parts of
this application are not completed and that if all required supporting documentation and attachments are not included, this
application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non -
discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties,
injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition
of this permit be violated. I also understand that if all required parts of this application package are not completed and that if
all required supporting information and attachments are not included, this application package will be returned to me as
incomplete.
NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false
statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may
include a fine not to exceed $10,00 as well as civil penalties up to $25,000 per violation.
Signature: "'V" Date:
FORM: FTA 04-16 Page 5 of 5
SEWER NARRATIVE
Stanbury Creek Off -Site Forcemain
Brunswick County, NC
Wayne's Backhoe Service, Inc.
20 Thomasboro Rd. SW
Calabash, NC 28467
(910) 579-7103
April 2020
Prepared by:
NORRIS & TUNSTALL CONSULTING ENGINEERS, P.C.
1429- Ash — Little River Road
Ash, North Carolina 28420
(910) 287-5900
(910) 287-5902 (Fax)
License # C-3641
N&T Project No. 19075
NARRATIVE
SEWER SYSTEM:
A total of 11,922 LF of 8-inch sewer forcemain will be needed to complete the system.
This will connect to a pump station already permitted under WQ0032228 but not yet
constructed.
This system will be owned and operated by the Brunswick County Public Utilities when
completed.