Loading...
HomeMy WebLinkAboutSW1190801_SuppEZ Form_5/12/2020SUPPLEMENT-EZ COVER PAGE FORMS LOADED 1 Project Name Leicester Volunteer Fire Department 2 Project Area (ac)10.68 3 Coastal Wetland Area (ac) 0 4 Surface Water Area (ac) 0 5 Is this project High or Low Density? High 6 Does this project use an off-site SCM? No 7 Width of vegetated setbacks provided (feet) N/A 8 Will the vegetated setback remain vegetated? No 9 Is BUA other that as listed in .1003(4)(c-d) out of the setback? No 10 Is streambank stabilization proposed on this project? No 11 Infiltration System 0 12 Bioretention Cell 2 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 0 17 Rainwater Harvesting (RWH) 0 18 Green Roof 0 19 Level Spreader-Filter Strip (LS-FS) 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LOADED 27 Name and Title: Jacob D. Grieb 28 Organization:Mattern & Craig 29 Street address: 403 E. Market Street 30 City, State, Zip: Johnson City, TN, 37601 31 Phone number(s): 423-979-2220 32 Email:jdgrieb@matternandcraig.com Certification Statement: Designer ______________________________________________ Signature of Designer ______________________________________________ Date I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. PROJECT INFORMATION NUMBER AND TYPE OF SCMs: DESIGNER CERTIFICATION COMPLIANCE WITH 02H .1003(4) Seal BIORETENTION CELL 1 Drainage area number 1 2 2 Design volume of SCM (cu ft)3405 cf 3989 cf 3 Is the SCM sized to treat the SW from all surfaces at build-out?Yes Yes 4 Is the SCM located away from contaminated soils?Yes Yes 5 What are the side slopes of the SCM (H:V)?3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No No 7 Are the inlets, outlets, and receiving stream protected from erosion (10-year storm)?Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume?Yes Yes 9 What is the method for dewatering the SCM for maintenance?Other Other 10 If applicable, will the SCM be cleaned out after construction?Yes Yes 11 Does the maintenance access comply with General MDC (8)?Yes Yes 12 Does the drainage easement comply with General MDC (9)?Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? 14 Is there an O&M Agreement that complies with General MDC (11)?Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)?Yes Yes 16 Does the SCM follow the device specific MDC?Yes Yes 17 Was the SCM designed by an NC licensed professional?Yes Yes 18 SHWT elevation (fmsl)< 2161.00 < 2149.00 19 Bottom of the bioretention cell (fmsl)2163.50 2151.50 20 Ponding depth of the design storm (inches)12 in 12 in 21 Surface area of the bioretention cell (square feet)3757 sf 4045 sf 22 Design volume of the bioretention cell (cubic feet)3405 cf 3989 cf 23 Is the bioretention cell used for peak attenuation?Yes Yes 24 Depth of peak attenuation over planting surface (in)24 in 24 in 25 Height of peak attenuation outlet above the planting surface (in)18 in 18 in 26 Infiltration rate of the in situ soil (inch/hour)N/A N/A 27 Diameter of the underdrain pipes (if applicable)4"4" 28 Does the design include Internal Water Storage (IWS)?Yes Yes 29 if so, elevation of the top of the IWS (fmsl)2165.5 2153.5 30 Elevation of the planting surface (fmsl)2167 2155 31 What type of vegetation will be planted? (grass, trees/shrubs, other)?Other Other 32 Media depth (inches)30 in 30 in 33 Percentage of medium to coarse washed sand by volume 75-80%75-80% 34 Percentage of fines (silt and clay) by volume 8-10%8-10% 35 Percentage of organic matter by volume 5-10%5-10% 36 Type of organic material ie: pine bark ie: pine bark 37 Phosphorus Index (P-Index) of media (unitless) <50 <50 38 Will compaction be avoided during construction?Yes Yes 39 Will cell be maintained to a one inch/hour standard?Yes Yes 40 Depth of mulch, if applicable (inches)N/A N/A 41 Type of mulch, if applicable N/A N/A 42 How many clean out pipes are being installed?2 2 43 Type of pretreatment that will be used:N/A N/A 44 Please use this space to provide any additional information about the bioretention cell(s): BIORETENTION CELL MDC FROM 02H .1052 GENERAL MDC FROM 02H .1050 ADDITIONAL INFORMATION 31. Sod Bioretention 1 11:55 AM 4/29/2020 DRAINAGE AREAS 1 Is this a high density project?Yes 2 If so, number of drainage areas/SCMs 2 3 Is all/part of this project subject to previous rule versions?No FORMS LOADED Entire Site 1 2 4 Type of SCM Bioretention Cell Bioretention Cell Bioretention Cell 5 Total BUA in project (sq ft)74199 sf 42254 sf 31945 sf 6 New BUA on subdivided lots (subject to permitting) (sq ft)0 sf 0 sf 0 sf 7 New BUA outside of subdivided lots (subject to permitting) (sf)74199 sf 42254 sf 31945 sf 8 Offsite - total area (sq ft)89569 sf 44845 sf 44742 sf 9 Offsite BUA (sq ft)0 sf 0 sf 15100 sf 10 Breakdown of new BUA outside subdivided lots: - Parking (sq ft)16396 sf 6156 sf 10240 sf - Sidewalk (sq ft)1663 sf 0 sf 1663 sf - Roof (sq ft)24640 sf 21184 sf 3456 sf - Roadway (sq ft)31500 sf 14914 sf 16586 sf - Future (sq ft)0 sf 0 sf 0 sf - Other, please specify in the comment box below (sq ft) 0 sf 0 sf 0 sf 11 New infiltrating permeable pavement on subdivided lots (sq ft)0 sf 0 sf 0 sf 12 New infiltrating permeable pavement outside of subdivided lots (sq ft)0 sf 0 sf 0 sf 13 Exisitng BUA that will remain (not subject to permitting) (sq ft)0 sf 0 sf 0 sf 14 Existing BUA that is already permitted (sq ft)0 sf 0 sf 0 sf 15 Existing BUA that will be removed (sq ft)0 sf 0 sf 0 sf 16 Percent BUA 19%17%24% 17 Design storm (inches)1 in 1 in 1 in 18 Design volume of SCM (cu ft)7394 cf 3405 cf 3989 cf 19 Calculation method for design volume Simple Method Simple Method Simple Method 20 DRAINAGE AREA INFORMATION ADDITIONAL INFORMATION Please use this space to provide any additional information about the drainage area(s):