Loading...
HomeMy WebLinkAbout20200579 Ver 1_Whirligig-SuppEZ-2018_20200511ID#* 20200579 Version* 1 Select Reviewer:* Katie Merritt Initial Review Completed Date 05/12/2020 Mitigation Project Submittal - 5/11/2020 Is this a Prospectus, Technical Proposal or a New Site?* O Yes a No Type of Mitigation Project:* r Stream r Wetlands G Buffer q Nutrient Offset (Select all that apply) Project Contact Information Contact Name:* Rebecca Stubbs, PE Project Information ................................................................................... ID#:* 20200579 Existing IW Project Type: Project Name: County: F DMS r Mitigation Bank Whirligig Station Wilson Document Information Email Address:* rstubbs@mcadamsco.com Version: * 1 Existing Version Mitigation Document Type:* Mitigation Information File Upload: Whirligig-SuppEZ-2018.pdf 513.4KB Rease upload only one R7F of the corrplete file that needs to be submtted... Signature Print Name:* Heather Dew, PE Signature:* 31Ur,rI—CMr_iYI—CL. 40VVr_M C'HVC FORMS LOADED OOP] IANCE VWTH 02H .1003 4 7 Wrdtb of vegetated setbacks,prov(ded, (feet NIA 8 Will the vecietated setback remain vegetated? No 9 Is BUA other that as listed in _1003�4)(c-d) out e. the setback'? Yes 10 is streambank stabilization proposed on this project? No —_.-- UMBER 11 AND TYPE OF SCMs: lnfiHraiiori S�rstem Bt3ioretenti in Cell _ 0 0 _ 0 _ 1 13 Wet Pond 14 Stormwater Wetland 0 15 Permeable Pavement b 16 Sand Filter 1 17 Rainwater Flares RWH 0 18 Green Roof 0 19 Level S)reader-Filter §tfo Disconnected lmpervious Surface(DIS) 0 20 0 21 Treatment Swale 0 22 Dry Pond D 23 5tormFilter 0 24 Silva Cell 0 25 BayW f 0 , 26 jFilteaa FQ] R S LOADED Certification Statement I certify; under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision, that the information provided in the form is, to the (lest of my knowledge and belief, true, accurate, and complete, and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent With the information provided here. = SEAS. 49073.2�? r ll� s r� `��ii�ealtit�! Date CaA w' 1CA;tidms O"t 1) DRAINAGE AREAS 1 Is this a high density project?Yes 2 If so, number of drainage areas/SCMs 1 3 Is all/part of this project subject to previous rule versions?No FORMS LOADED Entire Site 1 4 Type of SCM Sand Filter Sand Filter 5 Total BUA in project (sq ft)377194 sf 375066 sf 6 New BUA on subdivided lots (subject to permitting) (sq ft)0 0 7 New BUA outside of subdivided lots (subject to permitting) (sf)0 0 8 Offsite - total area (sq ft)0 0 9 Offsite BUA (sq ft)0 0 10 Breakdown of new BUA outside subdivided lots: - Parking (sq ft)200594 sf 198466 sf - Sidewalk (sq ft) - Roof (sq ft)101282 sf 101282 sf - Roadway (sq ft)75318 sf 75318 sf - Future (sq ft) - Other, please specify in the comment box below (sq ft) 11 New infiltrating permeable pavement on subdivided lots (sq ft) 12 New infiltrating permeable pavement outside of subdivided lots (sq ft) 13 Exisitng BUA that will remain (not subject to permitting) (sq ft)377194 sf 375066 sf 14 Existing BUA that is already permitted (sq ft)377194 sf 375066 sf 15 Existing BUA that will be removed (sq ft)0 0 16 Percent BUA 100%100% 17 Design storm (inches)1 in 1 in 18 Design volume of SCM (cu ft)22270 cf 22270 cf 19 Calculation method for design volume WQV=P*R*A/12 WQV=P*R*A/12 20 Entire Site 1 4 Type of SCM N/A 5 Total BUA from project (sq ft) 6 1995 rules SL 2006-246 2008 rules 2017 rules 7 New BUA on subdivided lots (subject to permitting) (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules 8 New BUA outside of subdivided lots (subject to permitting) (sf) 1995 rules SL 2006-246 2008 rules 2017 rules 9 Offsite - total area (sq ft) 1995 rules SL 2006-246 2008 rules 2017 rules 10 Offsite BUA (sq ft) 1995 rules SL 2006-246 DRAINAGE AREA INFORMATION DRAINAGE AREA INFORMATION ADDITIONAL INFORMATION "Parking" includes driveway and sidewalk. Please use this space to provide any additional information about the drainage area(s): 2008 rules 2017 rules 11 Design storm (inches) 1995 rules SL 2006-246 2008 rules 2017 rules 12 Breakdown of new BUA: - Parking (sq ft) - Sidewalk (sq ft) - Roof (sq ft) - Roadway (sq ft) - Future (sq ft) - Other, please specify in the comment box below (sq ft) 13 New infiltrating permeable pavement on subdivided lots (sq ft) 14 New infiltrating permeable pavement outside of subdivided lots (sq ft) 15 Exisitng BUA that will remain (not subject to permitting) (sq ft) 16 Existing BUA that is already permitted (sq ft) 17 Existing BUA that will be removed (sq ft) 18 Percent BUA 19 Design volume of SCM (cu ft) 20 Calculation method for design volume 21 Please use this space to provide any additional information about the drainage area(s): ADDITIONAL INFORMATION SAND FILTER 1 Drainage area number 1 2 Design volume of SCM (cu ft)22270 sf 3 Is the SCM sized to treat the SW from all surfaces at build-out? Yes 4 Is the SCM located away from contaminated soils?Yes 5 What are the side slopes of the SCM (H:V)?N/A 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No 7 Are the inlets, outlets, and receiving stream protected from erosion (10- year storm)? Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes 9 What is the method for dewatering the SCM for maintenance? Drawdown Orifice 10 If applicable, will the SCM be cleaned out after construction?Yes 11 Does the maintenance access comply with General MDC (8)?Yes 12 Does the drainage easement comply with General MDC (9)?Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? No 14 Is there an O&M Agreement that complies with General MDC (11)? Yes 15 Is there an O&M Plan that complies with General MDC (12)?Yes 16 Does the SCM follow the device specific MDC?Yes 17 Was the SCM designed by an NC licensed professional?Yes 18 SHWT elevation (fmsl) 130'-133' 19 Type of sand filter (open or closed)Closed 20 If closed, will the filter will be pre-cast or pour-in-place?Pre Cast 21 If closed, top of grate elevation (fmsl)135.33 22 Is this sand filter designed to attenuate peak flows?Yes 23 Volume that can be retained in the sediment chamber (cubic feet)4919 cf 24 Will there be a permanent pool in the sediment chamber?Yes 25 Bottom of the sediment chamber (fmsl)127.00 26 Area of the sediment chamber (square feet)2460 sf 27 Physical depth of the sediment chamber (inches)24 in 28 Ponding depth in the sediment chamber, above any permanent pool (inches) 30 in 29 Elevation of top of weir between chambers (fmsl)129 30 Volume that can be retained in the sand chamber (cubic feet)29027 cf 31 Bottom of the sand chamber (fmsl)127.00 32 Area of the sand chamber (square feet)6451 sf 33 Physical depth of the sand chamber (inches)54 in 34 Ponding depth in the sand chamber, above any permanent pool (inches) 30 in 35 Elevation of the bypass device (fmsl)131.5 36 Type of bypass device Weir 37 Mechanism for distributing flow over the sand surface Weir 38 Sand specification for sand chamber 39 Depth above underdrain pipe (inches)24 in 40 Will the media be maintained to drain at least two inches per hour at the sand surface? Yes 41 Is at least one clean-out pipe provided at the low point of each underdrain line? Yes 42 Will clean-out pipes be capped?Yes 43 Please use this space to provide any additional information about the Sand Filter(s): SAND FILTER MDC FROM 02H .1056 GENERAL MDC FROM 02H .1050 Sand Chamber Sediment Chamber ADDITIONAL INFORMATION Sand Filter 4 6:04 PM 4/8/2020