Loading...
HomeMy WebLinkAbout20200195 Ver 1_Revised Culvert Details_20200507Strickland, Bev From: Aliisa Harjuniemi <aliisa@cws-inc.net> Sent: Thursday, May 7, 2020 11:50 AM To: Johnson, Alan; Janiczak, Catherine M CIV USARMY CESAW (US) Subject: [External] Re: 20-0195 wilkinson project Attachments: GW28-Culvert Details.pdf External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to report.spam@nc.gov Alan and Cathy, See the revised culvert detail. Engineers wanted to know if this would be ok. Working on getting the stormwater plan from them as well. Thanks, Aliisa On Wed, Apr 29, 2020 at 3:59 PM Aliisa Harjuniemi <aliisagcws-inc.net> wrote: Alan, Last time I talked with the engineer they promised something by the end of last week. Will follow up again. Sorry for the delay. Engineers are saying everything takes them twice as long now when they are working remotely. Thanks, Aliisa On Wed, Apr 29, 2020 at 3:55 PM Johnson, Alan <alanJohnsonkncdenr.gov> wrote: Haven't heard anything. I had question about the culvert and SW. Let's get the engineer in gear or we may withdraw for failure to respond. Hope all is well Thanks 1 Alan DWR DNIA16n of WAter Itesoimmo!� Alan D Johnson — Senior Environmental Specialist NC Dept. of Environment & Natural Resources (NCDENR) Division of Water Resources - Water Quality Regional Operations 610 East Center Ave., Suite 301, Mooresville, NC 28115 Phone: (704) 235-2200 Fax: (704) 663-6040 E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. Aliisa Harjuniemi, PWS Project Manager Carolina Wetland Services, Inc. 550 E. Westinghouse Boulevard Charlotte, NC 28273 Direct: 980-259-1222 Office: 704-527-1177 www.cws-inc.net fcws-inc.netl Aliisa Harjuniemi, PWS Project Manager Carolina Wetland Services, Inc. 550 E. Westinghouse Boulevard Charlotte, NC 28273 Direct: 980-259-1222 Office: 704-527-1177 www.cws-inc.net fcws-inc.netl U � C N o 00 U�vi m� O N Nza UCD ( X Z OV NE O co a) N .0., fn Q O J CO y' Q V o a r- O O U LL � 00 O O O w " 3 O O + 630' 00 CONCRETE BAFFLES 20' SPACIN 620 IMEREWSWERk CULVERT PROP. GRADE AWE FLOW LINE J >- smommiminimmalsQ�1.771 00 som 0' 10'610 .50% OQ W L � PROP. CULVERT HEADWALL O(DESIGN BY OTHERS) PROP. CULVERT HEADWALL(DESIGN BY OTHERS)MENOMONEE O20'SPACIN109.73 LF 12' X 10' 600 Z REINFORCED CONCRETEBOX CULVERTEXIST. GRADE mmusaw 12'X 10'RCBC °c° NONE 109.73 LF @ 0.27% NONE PROP. 1'STREAM NONE 30" CONCRETE BAFFLES BED MATERIAL MEN00 (18" ABOVE STREAM BED MATERIAL) SPACED 10' 590 APART (TYP.) 15, NOTTO SCALE MMMMMMMMOME _� INV. OUT = 588.74 INV. OUT= 588.44 CUEVERT PEAN DETA580 Lu w 570 0� �00 NOT TO SCALEo CULVERT PROFILE DETAIL O 0 wW0 wO W0 12' X 10' wREBAR DOWELS TO REINFORCED CONVERTE BOX BE IMBEDDED INTO \RCBC, SIZED AND \ \ /O SPACED PER \ MANUFACTURERS\RECOMMENDATIONN OT TO SCALEBAFFLE DETAL PROJECT INFORMATION PROJECT MANAGER: JSC DESIGNED BY: CAT DRAWN BY: GMD PROJECT NUMBER: GW28.400 ORIGINAL DATE: 05/01/2020 SHEET: EXHIBIT II■■■■I■I■I■■ I; ■ ■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■■ ■■■■■■■■■■ ■■■■■■■■■■ ■■■■■■■■■■