HomeMy WebLinkAboutSW3161201_6 - Conservancy Ph2 Rev SW Plans 20200425_5/5/20205
5
0
560
570
580
650
640
6305405
5
0
5
4
0
5
5
0
5
8
0
5
7
0
600
610
620570
560
550
560570580
5
6
0550540
560
550
600
620
570
520
5
3
0
2287569.95SPUR NAIL
2285577.38SPUR NAIL
8260569.95SPUR NAIL
8258577.38SPUR NAIL
528526528
568566564 57057857413
520
525
518
5
5
2
551.
5
550
547546542546550546542550560+ 541.5
551
.
5
N6
5
°
5
9
'
1
6
"
W
3
0
1
.
5
3
'S22°32'20"E
346
.56
'
S47°24'01"
W 818.11'
N
5
0
°
0
6
'
3
8
"
W
4
0
4
.
1
2
'
N6
1
°
0
3
'
0
9
"
W
3
7
3
.
3
0
'
N
4
8
°
3
6
'
0
5
"W
2
1
2
.
3
4
'
N
5
2
°
4
5
'
2
4
"
W
1
9
5
.
7
2
'N35°57
'
5
7
"W
3
13
.2
5
'N22°50'40"W
355
.50
'
S66°
3
2
'
5
9
"
E
1
5
7
.
8
9
'N30°02'49"E 279.25'S77°19
'
3
7
"
E
6
2
7
.
0
4
'S28°40
'57
"E
374
.85
'
N60°5
2'
4
6"
E
2
1
2.
0
9'
S5
9
°
3
5
'
5
0
"
E
S
4
1
°
5
5
'
0
6
"
E
3
6
7
.
6
1
'
12
9
.
1
7
'S54°15
'32
"E
250
.33
'
S53°30'01"E 77.36'
L= 58.80' R= 255.0'
520518
521
522
S53°30'01"E 43.98'
S31°29'35"E 95.14'N26°44'57"E 332.85'522
544Date Issued For Rev
Scale
Checked By
Richard L. Modlin
Drawn By
Print Date
Sheet Number
True Homes
2649 Brekonridge Center Drive
Suite 104
Monroe, NC 28110
704.238.1229
Client Name
SWP-1Drawing File
Job Number
Site Plan
Sheet Title
The Conservancy
at Waxhaw Creek
Phase 2
Union County, North Carolina
Project Name
Providence Land Group, PLLC
3716 Providence Road South
Waxhaw, North Carolina 28173
704.400.0117
NC Firm #P-0910 ~ SC COA #4356
Surveyor
NOR T H CAROLI
NAMATTHE
W
J.S T I K E LEATHERORCA
L INNAL
N
OI ISS
E E
M O D
RGIN
L.ALT H
FORNO
D
I
CHA
R
EPRR E
N
SEAL
14937
Richard L. Modlin, PE
7215 Terrace Drive
Charlotte, North Carolina 28211
980.322.4191
Engineer
16079
Conservancy.dwg
LIMITS OF DISTURBED AREA
LIMITS OF DISTURBED AREA
FEMA FLOOD PLAIN
CONSERVATION AREA
PHASE 2
FEMA FLOOD PLAIN
PHASE 1
CONSERVATION AREA
STEELE RD (SR 1177)
PROPOSED FUTURE R/W
SHOWN FOR REFERENCE ONLY
11-28-16
Perennial RPW Stream
Wetland
(Approx. 6.75 acres)
Wetland (Approx. 6.75 acres)
Intermittent Seasonal RPW Sream
Intermittent Stream
PROPOSED 36" RCP CULVERT
PROPOSED WET POND, BMP-2
AT LOCATION OF EXISTING TEMPORARY
SKIMMER BASIN
Perennial RPW Stream
DRAINAGE AREA BOUNDARY
DRAINAGE AREA BOUNDARY
PHASE 3
(FUTURE)
SITE
LOCATION MAP
NO SCALE
Apr 25, 2020
GENERAL NOTES
1.CONTRACTOR SHALL BE RESPONSIBLE FOR ENSURING THAT ALL
CONSTRUCTION IS IN ACCORDANCE WITH THE
RECOMMENDATIONS OF THE ON-SITE GEOTECHNICAL ENGINEER.
2.GEOTECHNICAL INVESTIGATION SHALL BE PERFORMED PRIOR TO
CONSTRUCTION TO IDENTIFY THE SUITABILITY OF IN-SITU
MATERIALS. IF THE INFILTRATION RATE IS IN EXCESS OF 0.01
IN/HR, A CLAY LINER SHALL BE INSTALLED.
3.EMBANKMENT FILL SHALL BE PLACED IN MAXIMUM
UNCOMPACTED LIFTS OF 8 INCHES. FILL MATERIAL SHALL BE
APPROVED BY GEOTECHNICAL ENGINEER AND OBTAINED EITHER
ON-SITE OR FROM A SUITABLE OFF-SITE LOCATION. ALL FILL
MATERIAL SHALL BE FREE OF OBJECTIONABLE DEBRIS, WOOD
AND/OR STONES GREATER THAN 4 INCHES.
4.COMPACT FILL TO A MINIMUM 95% OF THE STANDARD
PROCTOR MAXIMUM DRY DENSITY.
5.CONTRACTOR SHALL SUBMIT SHOP DRAWINGS OF THE ALL RISER
STRUCTURE COMPONENTS FOR REVIEW.
6.RISER BARREL SHALL BE O-RING CLASS III RCP WITH TYPE 4
JOINTS IN ACCORDANCE WITH ASTM C-76 AND C-443.
7.RISER STRUCTURE JOINTS SHALL BE SEALED USING BUTYL
RUBBER SEALANT PER ASTM C-990. ALL PIPE CONNECTIONS TO
THE RISER BOX SHALL BE WATERTIGHT.
8.OPENINGS FOR OUTLET PIPE AND 2.0" INLET ORIFICE INDICATED
ON THE PLANS SHALL BE CAST INTO RISER UNIT. KNOCKOUTS OR
DRILLING IS NOT PERMITTED.
9.STEPS SHALL BE PROVIDED PER NCDOT STD. NO. 840.66.
10.ANTI-FLOTATION BLOCK SHALL BE CAST AS INTEGRAL PART OF
RISER BOX UNIT IF PRECAST.
11.ACCESS GRATE/FRAME SHALL BE HEAVY-DUTY ALUMINUM OR
STAINLESS STEEL AND PROVIDED WITH HINGES AND SECURITY
HASP SECURED TO CONCRETE RISER BOX. COORDINATE
LOCATION OF HINGES WITH PLACEMENT OF RISER STEP(S).
CONSTRUCTION SEQUENCE
1.CONTACT THE NORTH CAROLINA DEQ DMLR FOR A
PRECONSTRUCTION MEETING AT LEAST ONE WEEK PRIOR TO
BEGINNING CONSTRUCTION.
2.FLAG WORK LIMITS AND MARK TREES FOR PROTECTION.
3.INSPECT AND REPAIR CONSTRUCTION ENTRANCE AS
REQUIRED.
4.INSPECT AND REPAIR SILT FENCE AS REQUIRED.
5.INSPECT TEMPORARY SILT DTCHES AND DIVERSIONS AND
MAKE ANY NEEDED REPAIRS.
6.UPLAND AREAS DRAINING TO THE BASIN(S) SHOULD BE
STABILIZED BEFORE ATTEMPTING TO CONVERT TEMPORARY
BASIN TO PERMANENT STORMWATER MANAGEMENT
CONTROL.
7.DE-WATER AND REMOVE SILT ACCUMMULATIONS FROM
EXISTING TEMPORARY SEDIMENT BASINS. PROPERLY DISPOSE
OF ALL SPOIL. GRADE BASIN BOTTOM AND BEGIN
CONSTRUCTION OF EMBANKMENT AND SHAPING OF THE
BASIN AND FOREBAY TO THE DESIGN CONTOURS.
8.INSTALL CONCRETE RISER, OUTLET BARREL, RC FES, RIPRAP
APRON AND 8-INCH DRAWDOWN DRAIN. ATTACH SKIMMER
TO INLET END OF DRAWDOWN DRAIN TO ENABLE NEW POND
TO FUNCTION AS TEMPORARY SEDIMENT BASIN. INSTALL OR
REPLACE BAFFLES.
9.REMOVE TEMPORARY RISER AND PIPE AS SOON AS NEW
STRUCTURE IS IN PLACE AND THE RE-GRADED POND AREA IS
ABLE TO INTERCEPT AND CONTROL SEDIMENT-LADEN RUNOFF.
10.MINIMIZE THE SIZE AND CONTROL THE OPERATIONS OF
CONSTRUCTION EQUIPMENT WITHIN THE POND AREA.
11.STABILIZE ALL AREAS WITHIN 7 DAYS OF COMPLETION.
12.MAINTAIN NPDES LOG BOOK AS REQUIRED BY GENERAL
PERMIT.
13.SCHEDULE AN INSPECTION AND APPROVAL BY A
REPRESENTATIVE OF THE NORTH CAROLINA DEQ DMLR
SECTION PRIOR TO REMOVAL OF EROSION CONTROL
MEASURES.
14.TEMPORARY EROSION CONTROL MEASURES SHALL REMAIN IN
PLACE UNTIL PERMANENT STABILIZATION HAS BEEN ACHIEVED
AND APPROVAL HAS BEEN RECEIVED.
15.ALL SEDIMENT AND DEBRIS SHALL BE REMOVED FROM BASIN
PRIOR TO USE AS A PERMANENT WET DETENTION BASIN.
This drawing is not to be used for construction
purposes unless the signature of the responsible
registrant is affixed hereon and the appropriate
forms and fees have been sent to the Authority
having jurisdiction by the Owner, Owner's Agent,
or the Contractor.
PROPOSED WET-DETENTION POND, BMP-1
AT LOCATION OF EXISTING TEMPORARY
SKIMMER BASIN
EXISTING DEVELOPMENT
EROSION CONTROL MAINTENANCE PLAN
THE FOLLOWING MAINTENANCE PLAN SHALL BE FOLLOWED UNTIL THE SITE IS COMPLETELY
STABILIZED AFTER CONSTRUCTION. DURING CONSTRUCTION, THE CONTRACTOR SHALL BE
RESPONSIBLE FOR INSPECTION AND MAINTENANCE OF ALL EROSION AND SEDIMENT CONTROL
STRUCTURES.
1. ALL EROSION CONTROL MEASURES SHALL BE CHECKED FOR STABILITY AND OPERATION
FOLLOWING ANY RAINFALL PRODUCING RUNOFF AND AT LEAST ONCE EVERY WEEK. ANY
NEEDED REPAIRS SHALL BE MADE IMMEDIATELY SO THAT ALL EROSION CONTROL MEASURES
ARE MAINTAINED AS DESIGNED.
2. SEDIMENT TRAPS AND BASINS SHALL BE CLEANED OUT WHEN THE LEVEL OF SEDIMENT
REACHES THE MID-DEPTH POINT BELOW THE WEIR ELEVATION. WASHED STONE SHALL BE
CLEANED OR REPLACED WHEN THE SEDIMENT POOL NO LONGER DRAINS PROPERLY.
3. ALL SEEDED AREAS WILL BE FERTILIZED, RESEEDED AS NECESSARY, AND MULCHED IN
ACCORDANCE WITH THE SEEDING SPECIFICATIONS IN ORDER TO MAINTAIN A DENSE
VEGETATIVE COVER.
4. SEDIMENT DEPOSITS SHALL BE REMOVED FROM SEDIMENT FENCE AFTER EACH STORM EVENT
OR SEDIMENT FENCE SHOULD BE REPLACED. SEDIMENT MUST BE REMOVED WHEN
DEPOSITS REACH APPROX. HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS
REMAINING IN PLACE AFTER THE SEDIMENT FENCE IS REMOVED SHALL BE DRESSED TO
CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED.
5. INSPECT CHECK DAMS AND CHANNELS FOR DAMAGE AFTER EACH STORM EVENT. REMOVE
SEDIMENT ACCUMULATED BEHIND THE DAMS AS NEEDED TO PREVENT DAMAGE TO
CHANNEL VEGETATION. ADD STONE TO DAMS AS NEEDED TO MAINTAIN DESIGN HEIGHT
AND CROSS SECTION.
06-22-19 BMP modifications 1
04-25-20 Revised per DEQ 2
N6
5
°
5
9
'
1
6
"
W
3
0
1
.
5
3
'S22°32'20"E
346
.56
'
S47°24'01"
W 818.11'
N
5
0
°
0
6
'
3
8
"
W
4
0
4
.
1
2
'
N6
1
°
0
3
'
0
9
"
W
3
7
3
.
3
0
'
N
4
8
°
3
6
'
0
5
"W
2
1
2
.
3
4
'
N
5
2
°
4
5
'
2
4
"
W
1
9
5
.
7
2
'N35°57
'57
"W
313
.25
'N22°50'40"W
355
.50
'
S66
°
3
2
'
5
9
"
E
1
5
7
.
8
9
'N30°02'49"E 279.25'S77°19
'
3
7
"
E
6
2
7
.
0
4
'S28°40
'57
"E
374
.85
'
N60°
5
2'
4
6"
E
2
1
2.
0
9'
S5
9
°
3
5
'
5
0
"
E
S4
1
°
5
5
'
0
6
"E
3
6
7
.
6
1
'
12
9
.
1
7
'S54°15
'32
"E
250
.33
'
S53°30'01"E 77.36'
L= 58.80' R= 255.0'
S53°30'01"E 43.98'
S31°29'35"E 95.14'N26°44'57"E 332.85'Date Issued For Rev
Scale
Checked By
Richard L. Modlin
Drawn By
Print Date
Sheet Number
True Homes
2649 Brekonridge Center Drive
Suite 104
Monroe, NC 28110
704.238.1229
Client Name
SWP-1ADrawing File
Job Number
BUA Summary
Sheet Title
The Conservancy
at Waxhaw Creek
Phase 2
Union County, North Carolina
Project Name
Providence Land Group, PLLC
3716 Providence Road South
Waxhaw, North Carolina 28173
704.400.0117
NC Firm #P-0910 ~ SC COA #4356
Surveyor
NOR T H CAROLI
NAMATTHE
W
J.S T I K E LEATHERORCA
L INNAL
N
OI ISS
E E
M O D
RGIN
L.ALT H
FORNO
D
I
CHA
R
EPRR E
N
SEAL
14937
Richard L. Modlin, PE
7215 Terrace Drive
Charlotte, North Carolina 28211
980.322.4191
Engineer
16079
Conservancy.dwg
PHASE 2
PHASE 1
04-25-20
PHASE 3
(FUTURE)
SITE
LOCATION MAP
NO SCALE
Apr 25, 2020
This drawing is not to be used for construction
purposes unless the signature of the responsible
registrant is affixed hereon and the appropriate
forms and fees have been sent to the Authority
having jurisdiction by the Owner, Owner's Agent,
or the Contractor.
EXISTING
DEVELOPMENT
DRIVEWAY
L2 L3
L1
BUILDING
40' x 60'12'18'TYPICAL LOT IMPERVIOUS AREA
40
41
42
43
44
45
74
73
72
71
70
69
68
67
66
646362
61
60
59
58
57
56
55
54
53
51
50
49
48
47
75
52
39
27
28
65
FUTURE
DEVELOPMENTCOMMONOPENSPACE
46
CONSERVATION AREA
CO
M
M
O
N
O
P
E
N
S
P
A
C
E
5
0'
B
U
F
F
E
R
HAWKVIEW RD.HA
W
K
VI
E
W
R
O
A
D
5
0'
R/
WFAWN CREST
DR
IVE
50
'
R
/W
CO
NI
F
E
R
O
U
S
CI
R
C
L
E
5
0'
R/
W
SPACE
OPEN
COMMON
SPACE
COMMON
OPEN
COMMON
OPEN
SPACE
BUILDING PAD, TYP
CONCRETE DRIVEWAY, TYP
LOTS
18-FT PAVEMENT, TYP
BUA SUMMARY
PROJECT AREA: 53.85 AC = 2,345,706 SF
ON-SITE BUILDINGS: 37 x 2,400 sf ea = 88,800 SF
ON-SITE DRIVEWAYS: 37,521 SF
ON-SITE STREETS: 62,986 SF
TOTAL ON-SITE BUA: 189,307 SF
PERCENT BUA: 8.07%
STREETS
HAWK VIEW RD 19,256 SF
FAWN CREST DR 33,592 SF
CONIFEROUS CIR 10,138 SF
STREETS TOTAL 62,986 SF
04-25-20 New drawing issued 1
BUA SUMMARY
002600PAD=534.20PAD=
5
3
3.
5
0
5
3
2
532
53
0
532532536PAD=
5
3
3.
5
0 530525520
525
518
PAD=532
.
6
0
+ 517.0
+ 517.5
520518
521
522
522 R/WPC = 12+83.22PT = 13+27.09570580
580572571570570560580
580572572
5715705
5
2
55
1
.
5
55
0
547546542546550546542550560+ 541.5
55
1
.
5
544Date Issued For Rev
Scale
Checked By
Richard L. Modlin
Drawn By
Print Date
Sheet Number
True Homes
2649 Brekonridge Center Drive
Suite 104
Monroe, NC 28110
704.238.1229
Client Name
SWP-2Drawing File
Job Number
Enlarged BMP
Plans
Sheet Title
The Conservancy
at Waxhaw Creek
Phase 2
Union County, North Carolina
Project Name
Providence Land Group, PLLC
3716 Providence Road South
Waxhaw, North Carolina 28173
704.400.0117
NC Firm #P-0910 ~ SC COA #4356
Surveyor
NOR T H CAROLI
NAMATTHE
W
J.S T I K E LEATHERORCA
L INNAL
N
OI ISS
E E
M O D
RGIN
L.ALT H
FORNO
D
I
CHA
R
EPRR E
N
SEAL
14937
Richard L. Modlin, PE
7215 Terrace Drive
Charlotte, North Carolina 28211
980.322.4191
Engineer
Apr 25, 2020
16079
Conservancy.dwg
BMP-2BMP-1
20 LF 18" O-RING RCP @ 0.50%
18" RC FES
11-28-16
5' x 5' CONC RISER
36" RCP CULVERT
15" RCP CULVERT PSD EASEMENTPCC/PSD EASEMENTPR
O
P
E
R
T
Y
B
O
U
N
D
A
R
Y
100'
S
T
R
E
A
M
B
U
F
F
E
R
PROP
E
R
T
Y
B
O
U
N
D
A
R
Y
3:1
3:12:12:16:1
3:
1
6:
1
3:
1
2:12:1 PCC EASEMENT P
C
C
E
A
S
E
M
E
N
T
PROP 50
'
P
U
B
L
I
C
R
/
W
P
R
O
P
5
0
'
P
U
B
L
I
C
R
/
W
1
8
'
P
A
V
E
D
R
D
W
Y
18' PAVE
D
R
D
W
Y
06-22-19 BMP modifications 1
18" RC FES
20' EMERGENCY SPILLWAY ELEV 553.40
51 LF 18" O-RING RCP @ 0.50%
13 LF 8" DIP DRAWDOWN DRAIN
PROP. MAINTENANCE ACCESS
CONST. 10-FT-WIDE STABILIZED
DRIVEWAY OF 8" COMPACTED ABC
VEGETATIVE FILTER
(EXISTING WOODED AREA
@ 5% SLOPE)
RIPRAP APRON
La = 10'
W1 = 5'W2 = 12'
D50 = 4"Dmax = 6"
T = 12"
use filter fabric
5' x 5' CONC RISER
FOREBAY PCC/PSD EASEMENT15" RCP CULVERT
RIPRAP APRON
La = 10'
W1 = 5'W2 = 12'
D50 = 4"Dmax = 6"
T = 12"
use filter fabric
20' EMERGENCY SPILLWAY ELEV 523.90
12 LF 8" DIP DRAWDOWN DRAIN
PROP. MAINTENANCE ACCESS
CONST. 10-FT-WIDE STABILIZED
DRIVEWAY OF 8" COMPACTED ABC
FOREBAY
42" RCP
This drawing is not to be used for construction
purposes unless the signature of the responsible
registrant is affixed hereon and the appropriate
forms and fees have been sent to the Authority
having jurisdiction by the Owner, Owner's Agent,
or the Contractor.
3:
1
6:
1
3:
1
PROPERTY BOUNDARYRIPRAP CHANNEL
F
A
W
N
C
R
E
S
T
D
R
FAWN C
R
E
S
T
D
R
EXISTING TEMPORARY SEDIMENT
BASIN RISER, BARREL & SKIMMER
TO BE REMOVED.
EXISTING TEMPORARY SEDIMENT
BASIN RISER, BARREL & SKIMMER
TO BE REMOVED.
04-25-20 Revised per DEQ 2
2 2
520
525
518
+ 517.0
Shallow Land
(522.0 to 523.5)
Shallow Water
(521.0 to 522.0)
Shallow Land
(522.0 to 523.5)
+ 517.5
520518
521
522
522
PERM POOL ELEV 522.0
570570570560572570 5
5
2
55
1
.
5
55
0
547546542546550546542550560+ 541.5
55
1
.
5
Shallow Land
(546.5 to 547.0)
Shallow Water
(545.5 to 546.5)
Shallow Water
PERM POOL ELEV 546.5
(545.5 to 546.5)544Date Issued For Rev
Scale
Checked By
Richard L. Modlin
Drawn By
Print Date
Sheet Number
True Homes
2649 Brekonridge Center Drive
Suite 104
Monroe, NC 28110
704.238.1229
Client Name
SWP-3Drawing File
Job Number
BMP Planting
Plans
Sheet Title
The Conservancy
at Waxhaw Creek
Phase 2
Union County, North Carolina
Project Name
Providence Land Group, PLLC
3716 Providence Road South
Waxhaw, North Carolina 28173
704.400.0117
NC Firm #P-0910 ~ SC COA #4356
Surveyor
NOR T H CAROLI
NAMATTHE
W
J.S T I K E LEATHERORCA
L INNAL
N
OI ISS
E E
M O D
RGIN
L.ALT H
FORNO
D
I
CHA
R
EPRR E
N
SEAL
14937
Richard L. Modlin, PE
7215 Terrace Drive
Charlotte, North Carolina 28211
980.322.4191
Engineer
Apr 25, 2020
16079
Conservancy.dwg
BMP-2BMP-1
11-28-16
Planting Procedures
1.Conform to all applicable specifications for plantings of trees and shrubs, as detailed in NCDEQ Stormwater Design
Manual Chapter 6.
2.Lay out all plants according to species mixes, and at specified spacings and densities. Herbaceous emergents, grasses
and sedges for Zones 1, 2 and 3 are often best laid out at regular spacing in a recognizable pattern. Regular spacings
are easier to evaluate and provide for more uniform and rapid coverage.
3.Plantings in Zones 4, 5 and 6 should also be laid out according to the species mixes, and at the specified spacings and
densities, but appear more natural when a "random" pattern of spacings are used, for between plants is necessary for
adequate coverage.
4.Mulching for herbaceous emergents located in areas which will be permanently or regularly inundated is not desirable.
Plantings in Zones 4, 5 and 6, shall be mulched.
5.Plants must receive at least an inch of water from rainfall each week, or when soils in which herbaceous emergent
plants are located are no longer in a saturated state, it will be necessary to water the plantings.
6.Vary watering depending upon the age of the plants and environmental conditions as required. Once established, no
watering is anticipated.
7.Potable water is the preferred source of water. Other sources such as water trucks, or water pumped from safe
sources, may be used provided that they are known to be free of impurities and that the salinities are suitable for the
species being grown.
8.Moisture metering shall be employed and maintained by the landscape professional to monitor watering requirements..
Weed and Invasive Species Control
1.Invasive plant species populations shall be controlled throughout the course of the work. Where bare ground exists,
and where mud flats exist in drawn down wet planting zones, invasive species such as Japanese Hops, Porcelainberry
and other noxious weeds can easily gain a foothold, quickly displacing the desirable plantings, leading to a partial
failure of the planting site.
2.An integrated pest management (IPM) approach is recommended for control of invasive plant species. Monitoring for
the presence of invasive species is a component of a BMP establishment program. Maintenance, including the removal
of invasive plant species, is critical to the success of the plantings, preventing the spread of those species downstream
of the BMP as well.
3.Some weeds may be removed with herbicides using the "glove technique."
Herbivore Control
1.Minimize potential damage to planted vegetation by local wildlife, especially geese and deer.
Delivery, Handling and Storage
1.All plants shall be fresh and healthy, and be delivered to the site with their rootstocks preserved in similar conditions to
those in the growing nursery.
2.Trees and shrubs shall be left natural and unpruned prior to delivery. Bark, branches, and root systems shall be
protected from sun scald, drying, wind burn, sweating, whipping, and other handling and tying damage which destroys
their natural shape. Protective covering for plants shall be provided during shipping and delivery.
3.Store bulbs, corms, tubers and rhizomes in conditions similar to those in the growing nursery, at approximately 50 to 65
°F, until planting.
4.Deliver plants after preparations for planting have been completed, and install immediately.
5.If planting is delayed, set plants in the appropriate exposure for each species (sun, filtered sun, or shade), protect from
weather and mechanical damage, and keep roots moist. Depending on the length of delay, plants may need to be
heeled in.
6.Do not remove container grown stock from containers before time of planting, and water as often as necessary to
maintain root systems in a moist condition.
7.A two-year warranty period shall be required for all plantings. At the end of the first year and again at the end of the
two-year warranty period, all plants that do not survive must be replaced. Establishment procedures, such as control of
invasive weeds, animal and vandal damage, mulching, re-staking, watering and mesh or tube protection replacement,
shall be implemented to the extent needed to ensure plant survival.
Existing Vegetation Management
1.Identify and protect significant populations of, and individual specimens of trees and shrubs. This shall include
incorporating vegetation protection measures into initial erosion and sediment control plans.
2.Locate/identify invasive species and eradicate them prior to beginning site clearing, or other land disturbing operations.
3.Never chip and redistribute chipped plant parts from clearing operations when invasive species are present.
Soil Preparation
1.Perform soil testing for existing and prepared soils to be used for planting to determine types of soil amendments
required to bring soil to within the correct ranges for optimum plant growth. These tests may include pH, major soil
nutrients, including Nitrogen (N), Phosphorus (P) and Potassium (K) and organic content
2.If soils are amended, a second soil test is needed prior to planting. If imported soil is used, a manufacturer certification
is required.
3.Remove all construction debris prior to placement of any topsoil.
4. If areas around the BMP are disturbed due to construction, the top 6 to 8 inches of the affected area(s) shall be tilled
and proper soil mix applied in horizontal layers not exceeding 12 inches. Placement of soils shall not be done when
soils are saturated. Restrict construction traffic from areas of soil mixing/placement.
3.Topsoil should be spread to a depth of eight to twelve inches (deeper for balled and burlaped trees) and lightly
compacted to minimum thickness of six inches. If topsoil has been stockpiled for a long period of time, verify and/or
adjust the soil pH, and major soil nutrients to achieve the minimum acceptable standards.
PERMANENT SEEDING SCHEDULE FOR EMBANKMENT
TEMPORARY SEEDING SCHEDULE
PLANTING SCHEDULE
SYMBOL
05-09-19 BMP modifications 1
This drawing is not to be used for construction
purposes unless the signature of the responsible
registrant is affixed hereon and the appropriate
forms and fees have been sent to the Authority
having jurisdiction by the Owner, Owner's Agent,
or the Contractor.
04-25-20 Updated 2
2
550
560570580 650
640630540550
540
550
580
570
600610
62057056055056
0
57
0
580560
550540560550600620570520530
2287
569.95
SPUR
N
AI
L
2285
577.38
SPUR
N
A
I
L
8260 569.95
SPUR
N
AI
L
8258 577.38
SPUR
N
A
I
L528526528
568
566
56
4
5
7
0
5
7
8
5
7
4
107
3A
3B
4B
1
4A
2
3C
Off-site area to BMP-2
3.54 AC
Off-site area to BMP-2
3.18 AC
15.75 Ac
On-site to BMP-2
0.83 AC
10.62 AC
BMP-1
17.26 Ac
9.15 AC
Date Issued For Rev
Scale
Checked By
Richard L. Modlin
Drawn By
Print Date
Sheet Number
True Homes
2649 Brekonridge Center Drive
Suite 104
Monroe, NC 28110
704.238.1229
Client Name
SWP-4Drawing File
Job Number
Sheet Title
The Conservancy
at Waxhaw Creek
Phase 2
Union County, North Carolina
Project Name
Providence Land Group, PLLC
3716 Providence Road South
Waxhaw, North Carolina 28173
704.400.0117
NC Firm #P-0910 ~ SC COA #4356
Surveyor
NOR T H CAROLI
NAMATTHE
W
J.S T I K E LEATHERORCA
L INNAL
N
OI ISS
E E
M O D
RGIN
L.ALT H
FORNO
D
I
CHA
R
EPRR E
N
SEAL
14937
Richard L. Modlin, PE
7215 Terrace Drive
Charlotte, North Carolina 28211
980.322.4191
Engineer
Apr 25, 2016
16079
Conservancy.dwg
Pre-Development
Drainage Area Map
11-28-16
This drawing is not to be used for construction
purposes unless the signature of the responsible
registrant is affixed hereon and the appropriate
forms and fees have been sent to the Authority
having jurisdiction by the Owner, Owner's Agent,
or the Contractor.
04-25-20 Minor update 1
550
560570580 650
640630540550
540
550
580
570
600610
62057056055056
0
57
0
580560
550540560550600620570520530
2287
569.95
SPUR
N
AI
L
2285
577.38
SPUR
N
A
I
L
8260 569.95
SPUR
N
AI
L
8258 577.38
SPUR
N
A
I
L528526528
568
566
56
4
5
7
0
5
7
8
5
7
4
38
107
532
532
530 532532536530525520
525
518
570580580572571570570560580580572
572571570552
551.5550
547546542546550546542550560+ 541.5+ 517.0551.5
3A
3B
4B
1
4A
2
3C+ 517.5520518 521522
Off-site area to BMP-2
3.54 AC
Off-site area to BMP-2
3.18 AC
15.75 Ac
On-site to BMP-2
0.83 AC
10.62 AC
BMP-1
17.26 Ac
9.15 AC522 544Date Issued For Rev
Scale
Checked By
Richard L. Modlin
Drawn By
Print Date
Sheet Number
True Homes
2649 Brekonridge Center Drive
Suite 104
Monroe, NC 28110
704.238.1229
Client Name
SWP-5Drawing File
Job Number
Sheet Title
The Conservancy
at Waxhaw Creek
Phase 2
Union County, North Carolina
Project Name
Providence Land Group, PLLC
3716 Providence Road South
Waxhaw, North Carolina 28173
704.400.0117
NC Firm #P-0910 ~ SC COA #4356
Surveyor
NOR T H CAROLI
NAMATTHE
W
J.S T I K E LEATHERORCA
L INNAL
N
OI ISS
E E
M O D
RGIN
L.ALT H
FORNO
D
I
CHA
R
EPRR E
N
SEAL
14937
Richard L. Modlin, PE
7215 Terrace Drive
Charlotte, North Carolina 28211
980.322.4191
Engineer
Apr 25, 2020
16079
Conservancy.dwg
Post-Development
Drainage Area Map
11-28-16
This drawing is not to be used for construction
purposes unless the signature of the responsible
registrant is affixed hereon and the appropriate
forms and fees have been sent to the Authority
having jurisdiction by the Owner, Owner's Agent,
or the Contractor.
05-09-19 BMP modifications 1
2
04-25-20 Updated base plan 2
Date Issued For Rev
Scale
Checked By
Richard L. Modlin
Drawn By
This drawing is not to be used for construction
purposes unless the signature of the responsible
registrant is affixed hereon and the appropriate
forms and fees have been sent to the Authority
having jurisdiction by the Owner, Owner's Agent,
or the Contractor.
Print Date
Sheet Number
True Homes
2649 Brekonridge Center Drive
Suite 104
Monroe, NC 28110
704.238.1229
Client Name
SWP-6Drawing File
Job Number
Stormwater
Management
Details
BMP-1
Sheet Title
Project Name
Providence Land Group, PLLC
3716 Providence Road South
Waxhaw, North Carolina 28173
704.400.0117
NC Firm #P-0910 ~ SC COA #4356
Surveyor
NOR T H CAROLI
NAMATTHE
W
J.S T I K E LEATHERORCA
LINNAL
N
OI ISS
E E
M O D
RGIN
L.ALT H
FORNO
DICHA
R
EPRR E
N
SEAL
14937
Richard L. Modlin, PE
7215 Terrace Drive
Charlotte, North Carolina 28211
980.322.4191
Engineer
The Conservancy
at Waxhaw Creek
Phase 2
Union County, North Carolina
16079
Conservancy.dwg
11-28-16
Apr 25, 2020
OUTLET STRUCTURE- SECTION
RIP RAP APRON
INV ELEV. 519.88
18" RC FLARED END SECTION3:
13:1ELEV. 525.02-YR WATER SURFACE ELEV 523.32
50-YR WATER SURFACE ELEV 523.81
NOT TO SCALE
SECTION THRU EMBANKMENT
18" O-RING RCP BARREL
WQv ORIFICE ELEV 522.00
4' WEIR ELEV 523.40
25-YR WATER SURFACE ELEV. 523.74
5' x 5' CONCRETE RISER
ANTI-FLOTATION BLOCK
WQv WATER SURFACE ELEV 523.42
PERMANENT POOL ELEV. 522.00
WQv SIPHON 3:16:1
TOP OF VEGETATED SHELF ELEV 522.50
INV. ELEV 520.0
TOP ELEV 523.90
FOREBAY
ELEV 523
STEPS PER NCDOT STD. 840.66
HINGED ALUMINUM ACCESS GRATE/TRASH RACK
WITH SQUARE OPENINGS NOT GREATER THAN 6"
8" DIP DRAWDOWN DRAIN
ANTI-SEEP COLLAR
ANTI-FLOTATION BLOCK
WATER QUALITY SIPHON
4-FT-WIDE WEIR OPENING
16"8" DIP DRAWDOWN DRAIN
OUTLET STRUCTURE- PLAN
ANTI-FLOTATION BLOCK
WATER QUALITY SIPHON
STEPS PER NCDOT STD. 840.66
5' x 5' CONCRETE RISER
4' WEIR OPENING12"12"4'4'1.5'1.5'
1.5'
4' WEIR OPENING
(OPENING ON 2 SIDES)
(TWO SIDES)
WATER QUALITY SIPHON
24"
4" PVC ADAPTOR SPG
WITH SCREW-TYPE PLUG
4" x 2" PVC REDUCER
ORIFICE INV ELEV 522.00
RISER
4" PVC
1"14"12"BOTTOM OF VEGETATED SHELF ELEV 521.50
ELEV. 518.0
(1-YR 24-HOUR STORM)
3
:
1 2:12:1PLUG VALVE & HAND WHEEL
PER AWWA C504 SECT. 5.5
8" DIP DRAWDOWN DRAIN
WITH TRASH RACK AT
INLET OPENING
1.0'
ELEV. 524.00
ELEV. 525.0
20'
EMERGENCY SPILLWAY3:13:
1
6'
VEGETATED
SHELF
ELEV. 517.50
10'
2
BMP-1
05-09-19 BMP modifications 1
ELEV. 517.00
04-25-20 Revised per DEQ 2
MIN. 12"MIN. 12"
PERMANENT POOL ELEV. 522.00
42" CLEANOUT DEPTH48" CLEANOUT DEPTHENTRANCEEXIT48" CLEANOUT DEPTH(SEE DETAIL THIS SHEET)
Date Issued For Rev
Scale
Checked By
Richard L. Modlin
Drawn By
Print Date
Sheet Number
True Homes
2649 Brekonridge Center Drive
Suite 104
Monroe, NC 28110
704.238.1229
Client Name
SWP-7Drawing File
Job Number
Stormwater
Management
Details
BMP-2
Sheet Title
Project Name
Providence Land Group, PLLC
3716 Providence Road South
Waxhaw, North Carolina 28173
704.400.0117
NC Firm #P-0910 ~ SC COA #4356
Surveyor
NOR T H CAROLI
NAMATTHE
W
J.S T I K E LEATHERORCA
LINNAL
N
OI ISS
E E
M O D
RGIN
L.ALT H
FORNO
DICHA
R
EPRR E
N
SEAL
14937
Richard L. Modlin, PE
7215 Terrace Drive
Charlotte, North Carolina 28211
980.322.4191
Engineer
The Conservancy
at Waxhaw Creek
Phase 2
Union County, North Carolina
16079
Conservancy.dwg
11-28-16
Apr 25, 2020
OUTLET STRUCTURE- SECTION OUTLET STRUCTURE- PLAN WATER QUALITY SIPHON
NOT TO SCALE
ANTI-FLOTATION BLOCK
24"
4" PVC ADAPTOR SPG
WITH SCREW-TYPE PLUG
4" x 2.5" PVC REDUCER
ORIFICE INV ELEV 546.50
RISER
4" PVC
ANTI-FLOTATION BLOCK
WATER QUALITY SIPHON
STEPS PER NCDOT STD. 840.664' WEIR OPENING
4' WEIR OPENING12"12"STEPS PER NCDOT STD. 840.66
8" DIP DRAWDOWN DRAIN
ANTI-SEEP COLLAR
ANTI-FLOTATION BLOCK
WATER QUALITY SIPHON
4-FT-WIDE WEIR OPENING
1"14"12"4'4'16"RIP RAP APRON
INV ELEV 541.5
18" RC FLARED END SECTION
3:
1
3:1
ELEV. 551.50
2-YR WATER SURFACE ELEV 549.36
50-YR WATER SURFACE ELEV 550.39
18" O-RING RCP BARREL
WQv ORIFICE ELEV 546.50
4' WEIR ELEV 549.80
25-YR WATER SURFACE ELEV. 550.28
5' x 5' CONCRETE RISER
PERMANENT POOL ELEV. 546.5
WQv SIPHON (SEE DETAIL THIS SHEET)
3:1
6:1
3
:
1
TOP OF VEGETATED SHELF ELEV 547.00
INV. ELEV 542.0
TOP ELEV 550.30
FOREBAY
ELEV 547.50
2:12:18" DIP DRAWDOWN DRAIN
WQv WATER SURFACE ELEV 549.45
1.5'1.5'
1.5'
ON TWO SIDES
5' x 5' CONCRETE RISER
ON TWO SIDES
6'
ELEV 542.0
(1-YR, 24-HOUR STORM)
BOTTOM OF VEGETATED SHELF ELEV 546.00
PLUG VALVE & HAND WHEEL
PER AWWA C504 SECT. 5.5
8" DIP DRAWDOWN DRAIN
WITH TRASH RACK AT
INLET OPENING
HINGED ALUMINUM ACCESS GRATE/TRASH RACK
WITH SQUARE OPENINGS NOT GREATER THAN 6"
1.5'
ELEV. 550.00
ELEV. 551.50
20'
EMERGENCY SPILLWAY
VEGETATED
FILTER
100'
PROPERTY BOUNDARY
12'
VEGETATED
SHELF
SECTION THRU EMBANKMENT
2
BMP-2
10'
05-09-19 BMP modifications 1
This drawing is not to be used for construction
purposes unless the signature of the responsible
registrant is affixed hereon and the appropriate
forms and fees have been sent to the Authority
having jurisdiction by the Owner, Owner's Agent,
or the Contractor.
MIN. 12"
ELEV 541.00ELEV 540.50
04-25-20 Revised per DEQ 2