HomeMy WebLinkAboutNCG020072_NOV_20140331 A ' �4( .
VA
NMENR
North Carolina Department of Environment and Natural Resources
Pat McCrory
Governor John E. Skvarla, I11
Secretary
:larch 3 1. 2014
CERTIFIED MAIL #7012 1640 00019605 7799
RETURN RECEIPT REQUESTED
Mr. Brian M. Pfohl
Carolina Sunrock, LLC
200 Horizon Drive,Suite 100
Raleigh, NC 276IS
Subject: Notice of Violation
NOV-2014-PC-0082
Carolina Sunrock—Butner Quarry
NPDES Stormwater Permit NCG020072
Granville County
Dear Mr. Pfohl:
On March 25, 2014, Dave Parnell,from the Raleigh Regional Office of the North Carolina
Division of Energy, Mineral and Land Resources (DEMLR) conducted a compliance evaluation
inspection (CEI) at the referenced facility, located at 1001 West B Street in Butner, North
Carolina. Cheng Zhang of the Division of Water Resources (DWR) accompanied Mr. Parnell
during the site visit. The facility lies in the watershed of an unnamed tributary(UT) to Falls
Lake, in the Neuse River Basin.
The following observations were noted during the DEMLR inspection and file review:
This facility is a gravel mining operation. Mr. Tony Sample was available on site during the
inspection and provided valuable assistance to DEMLR and DWR staff.
Division of Energy, Mineral, and Land Resources
Energy Section -Geological Survey Section-Land Quality Section
1612 Mail Service Center, Raleigh, North Carolina 27699-1612.919-707-9200/FAX:919-715-8801
512 North Salisbury Street,Raleigh, North Carolina 27604•Internet:hft :l/ ortal.ncdenr.or lweb/Ir/
An Equal Opportunity 1 Affirmative Action Employer—50%Recycled 110%Post Consumer Paper
Stormwater run-off generated at such facilities is regulated by general NPDES stormwater
permit NCG020000. The DEMLR Stormwater Program has issued certificate of coverage
(COC) NCG020072. The permit is current and was available to Mr. Parnell during a document
review meeting,at the office of Mr. Sample, on March 28, 2014. The Stormwater Pollution
Prevention Plan (SPPP) was reviewed by Mr. Parnell during that meeting. The SPPP met the
intent of the NPDES permit. The Sunrock Butner Quarry has on-site tanks which are utilized
during vehicle maintenance. The tanks were secured with secondary containment.
Mr. Sample stated that he had failed to monitor the stormwater discharge outfalls (SDO),
qualitatively and analytically,since 2010. It was at that time,the facility had ended a contract
with a monitoring consultant. A subsequent file review revealed a Notice of Violation was
issued for failing to monitor the SDO -dated July 10, 2008 (NOV-2008-PC-0498). SDO are to
be analytically sampled once during a six month period, except when discharging wastewater,
as is SDO # 10,which is monitored quarterly.
The stormwater collection system location and the drainage area flowing to each SDO were
reviewed during the inspection. Process water was flowing from the dewatering pond
through Outfall #10 during the site visit.
Requested response: You are directed to respond to this letter in writing to DEMLR at the
address provided below within 30 days of receipt Please address the following items
noted in bold:
• Please provide a monitoring plan for the facility. Include in the monitoring plan,
required qualitative and analytical monitoring of the Stormwater Discharge Outfalls.
Additionally, pay particular attention to the permit requirement that analytical
monitoring of the wastewater process water must be implemented on a monthly basis,
when a facility fails to monitor.
• Please adhere to the requirements of the NPDES permit with respect to the Tier
program.
Please respond to:
Dave Parnell
NCDENR/DEMLR
Raleigh Regional Office
1628 Mail Service Center
Raleigh, NC 27699-162
Thank you for your attention to this matter. This office requires that the violations, as described
above, be properly resolved. Unresolved violations may lead to assessments of civil penalties.
Should you have questions regarding these matters, please contact Dave Parnell at (919) 791-
4200.
Sincerely,
Jo n L. Holley,Jr., PE, SC
egional Engineer
Raleigh Regional Office
cc: Stormwater Permitting Program Files-with attachment
DEMLR Raleigh Regional Office Files-with attachment
DWR Raleigh Regional Office Files-with attachment
Compliance Inspection Report
Permit: NCG020072 Effective: 01/01/10 Expiration: 12/31/14 Owner: Carolina Sunrock LLC
SOC: Effective: Expiration: Facility: Butner Mining and Concrete Facility
County: Granville 100 Sunrock Dr
Region: Raleigh
Butner NC 27509
Contact Person: Tony Sample Title: Phone: 919-575-4502
Directions to Facility:
System Classifications:
Primary ORC: Certification: Phone:
Secondary ORC(s):
On-Site Representative(s):
Related Permits:
Inspection Date: 03125/2014 Entry Time: 10:30 AM Exit Time: 12:30 PM
Primary Inspector: David R Parnell Phone: 919-791-4260
Secondary Inspector(s):
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Mining Activities Stormwater Discharge COC
Facility Status: Q Compliant ■Not Compliant
Question Areas:
Storm Water
(See attachment summary)
Page: 1
Permnt: NCGO20072 Owner•Fawlity: Carakna St nnx*LLC
Inspection Data: MS20:4 Inspection Type: Compbance Evaluatan Reason for Visit: Routine
Stormwater Pollution Prevention Plan Yes No NA NE
Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ ❑ ❑
Does the Plan include a General Location(USGS)map? ■ ❑ n ❑
#Does the Plan include a*Narrative Description of Practices'? ■ ❑ ❑ ❑
#Does the Plan mciude a detailed site map including outfall locations and drainage areas? ■ ❑ ❑ ❑
#Does the Plan include a list of significant spills occurring during the past 3 years? ■ ❑ ❑ ❑
#Has the facility evaluated feasible alternatives to current practices? ■ ❑ ❑ ❑
#Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑
#Does the Plan include a BMP summary? ■ ❑ ❑ ❑
#Does the Plan include a Spill Prevention and Response Plan(SPRP)? ■ ❑ ❑ ❑
#Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑
#Does the facility prowde and document Employee Training? ■ ❑ ❑ ❑
#Does the Plan include a list of Responsible Party(s)? ■ ❑ ❑ ❑
#Is the Plan reviewed and updated annually? ■ ❑ ❑ ❑
#Does the Plan include a Stormwater Facility Inspection Program? ■ n Q ❑
Has the Stormwater Pollution Prevention Plan been implemented? ■ n n n
Comment: A review of the facility's plan was done on line in the Sunrock Office on
3/28/14. Field inspection was conducted on 3/25/14.
Qualitative Monitoring Yes No NA NE
Has the facility conducted its Qualitative Monitoring semi-annually? ❑ ■ n ❑
Comment: Qualitative Monitoring is not being done.
Analytical Monitoring Yes No NA NE
Has the facility conducted its Analytical monitoring? n ■ ❑ n
#Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? n ■ ❑ ❑
Comment: Analytical Monitoring is not being done.
Permit and Outfalls Yes No NA NE
#Is a copy of the Permit and the Certificate of Coverage available at the site? ■ ❑ ❑ n
#Were all outfalls observed during the inspection? ■ ❑ n n
#If the facility has representative outfall status,is it properly documented by the Division? ❑ n ■ n
#Has the facility evaluated all illicit(non stormwater)discharges? ❑ ❑ ■ ❑
Comment:
Page: 3
P+en'tiR vCGIk.VGi2 O.nw•F�twb C�rt�err Sw+roc,4 llC
10"O+cINon Daft "2Sw*4 f"m COS Evombon Reaeon low Vielt: Routine
a