Loading...
HomeMy WebLinkAboutWQ0016140_Application_19981117State, of North Carolina 'Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary A. Preston Howard, Jr., P.E., Director November 17, 1998 Mr. David Harris, Executive Director Cameron Automotive/MOWASA P. O. Box 1027 Carthage, NC 28327 NCDENR NORTH AN ENVIRONMENTNT AND L P�OV 19 1998 FAYET TEVI LLE REG. OFFICE Subject: Application No. WQ0016140 Cameron Automotive Sewer -Public Moore County Dear Mr. Harris: The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on November 16, 1998. This application has been assigned the number listed above. Your project has been assigned to Mr. Ron Palumbo for a detailed engineering review. Should there be any questions concerninCD g your project, the reviewer will contact you with a request for additional information. Be aware that the Division's Regional Office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the division. If you have any questions, please contact Mr. Ron Palumbo at 919/733-5083 ext. 533. If the engineer is unavailable, you may leave a message on their voice mail and they will respond promptly. PLEASE REFER TO THE ABOVE APPLICATION NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. Sincerely, "r. Kim H. Colson, P.E. Supervisor, Non -Discharge Permitting Unit cc: Fayetteville Regional Office, Water Quality Nelson Consulting, Inc. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper MEMO TO: State Review Group Division of Water Quality FROM: Ricky Revels Fayetteville Regional Office SUBJECT: Procedure Four (4) December 14, 1999 WQ0016140 Date Cameron Automotive Sewer Extension -Public Town of Carthage Moore County State Review Group Review Engineer Ron Palumbo Regional Office Contact Ric4 Revels 1) Name of wastewater treatment plant to receive the wastewater: Moore Co. Regional WWTP 2) WWTP design capacity 6.7000 MGD 3) NPDES Permit No. NCO037508 Expiration Date: 11/30/1999 4) Compliance Information: Present treatement plant performance for previous _12_ months, beginning 97/01 & 97/11 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 500 GPD domestic X_ industrial other 6) Volume from previously approved projects not yet tributary to WWTP: -52,000-GPD previously approved flows began with WQ0015947 dated 12/11/98 7) Regional Recommendations: Approval X Denial RR/rr Enclosure GKEX88/MP 12/03/98 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 1 4 PERMIT--NC0037508 PIPE--001 REPORT PERIOD: 9701-9712 LOC --- E FACILITY--MOORE CO WWTP DESIGN FLOW-- 6.7000 CLASS--4 LOCATION--CARTHAGE REGION/COUNTY--06 MOORE 50050 00310 00530 00610 31616 50060 00300 TGP3B MONTH Q/MGD BOD RES/TSS NH3+NH4- FEC COLI CHLORINE DO CERI7DPF LIMIT F 6.7000 F 30.00 F 30.0 NOL F 200.0 NOL NOL NOL 97/01 4.6645 4.21 3.5 .27 14.1 185.238 9.83 97/02 4.7321 3.93 4.3 .10 14.7 102.500 10.36 97/03 4.8741 3.27 5.0 .10 27.2 142.250 9.86 1 LIMIT F 6.7000 F 22.00 F 30.0 17.00 F 200.0 NOL NOL NOL 97/04 4.7633 3.60 6.1 .10 15.8 101.818 9.17 97/05 4.8483 2.59 4.6 .10 13.3 117.619 9.07 97/06 4.8233 2.26 2.7 .10 17.9 98.095 8.94 1 97/07 5.2935 2.51 4.9 .10 22.5 122.272 8.59 97/08 5.1387 2.50 4.2 .10 12.3 143.333 8.42 97/09 4.8533 2.60 6.4 .10 17.1 131.904 8.61 1 97/10 4.7741 3.03 4.0 .10 15.3 149.565 9.20 LIMIT F 6.7000 F 30.00 F 30.0 NOL F 200.0 NOL NOL NOL 97/11 4.6333 3.62 7.3 .47 11.3 144.117 10.10 97/12 4.4548 3.11 5.3 .10 16.9 148.000 9.78 AVERAGE 4.8211 3.10 4.8 .14 16.5 132.225 9.32 1 MAXIMUM 8.4000 7.70 13.2 4.90 192.0 600.000 14.00 1 MINIMUM 2.3000 2.00 2.0 .10 1.0 30.000 5.70 1 UNIT MGD MG/L MG/L MG/L #/100ML UG/L MG/L PASS/FAI GKEX88/MP 12/03/98 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 2 PERMIT--NC0037508 PIPE--001 REPORT PERIOD: 9701-9712 LOC --- E FACILITY--MOORE CO WWTP DESIGN FLOW-- 6.7000 CLASS--4 LOCATION--CARTHAGE REGION/COUNTY--06 MOORE 00010 00400 00600 00665 00720 01042 01077 01092 MONTH TEMP PH TOTAL N PHOS-TOT CYANIDE COPPER SILVER ZINC LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL NOL 97/01 15.23 8.1-7.0 18.500 1.5500 .0000 7.5000 .0000 26.5000 97/02 97/03 LIMIT 97/04 97/05 97/06 97/07 97/08 97/09 97/10 LIMIT 97/11 97/12 AVERAGE MAXIMUM MINIMUM UNIT 15.00 7.8-7.4 16.650 1.3800 17.15 7.8-7.0 17.200 1.2800 NOL 9.0 6.0 NOL NOL 18.45 7.9-7.3 16.900 1.4000 .0000 8.5000 .0000 8.5000 NOL NOL .0000 7.5000 .0000 27.5000 .0000 28.0000 NOL NOL .0000 26.5000 20.47 7.8-7.2 14.900 2.0500 .0000 8.5000 .0000 21.5000 22.71 7.7-7.3 11.100 2.7000 .0000 10.0000 .0000 16.5000 25.22 7.8-7.5 16.500 1.8200 .0000 8.5000 .0000 17.0000 25.38 7.8-7.4 20.400 2.5900 .0000 11.0000 .0000 15.0000 24.52 7.6-7.2 15.800 2.2600 .0000 9.5000 .0000 31.0000 22.34 7.6-7.2 12.200 1.7500 .0000 7.0000 .0000 35.5000 NOL 9.0 6.0 NOL NOL NOL NOL NOL NOL 19.00 7.6-6.9 15.080 2.1000 .0000 10.0000 .0000 27.5000 16.45 7.4-7.0 17.800 1.8700 .0000 10.5000 .0000 23.5000 20.16 16.085 1.8958 .0000 8.9166 .0000 24.6666 27.00 8.100 20.400 2.7000 12.0000 40.0000 14..00 6.900 11.100 1.2800 6.0000 12.0000 DEG.0 SU MG/L MG/L UG L UG/L UG L UG/L GKEX88/MP 12/03/98 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 1 PERMIT--NC0037508 PIPE--001 REPORT PERIOD: 9711-9810 LOC --- E FACILITY--MOORE CO WWTP DESIGN FLOW-- 6.7000 CLASS--4 LOCATION--CARTHAGE REGION/COUNTY--06 MOORE 50050 00310 00530 00610 31616 50060 00300 TGP3B MONTH Q/MGD BOD RES/TSS NH3+NH4- FEC COLI CHLORINE DO CERI7DPF LIMIT F 6.7000 F 30.00 F 30.0 NOL F 200.0 NOL NOL 97/11 4.6333 3.62 7.3 .47 11.3 144.117 10.10 LIMIT F 6.7000 F 30.00 F 30.0 NOL F 200.0 NOL NOL NOL 97/12 4.4548 3.11 5.3 .10 16.9 148.000 9.78 98/01 5.2806 3.53 6.1 .10 18.2 165.789 9.96 1 98/02 6.1892 2.98 5.8 .10 7.9 203.000 10.14 98/03 6.3870 3.29 5.1 .10 15.3 167.272 10.37 1 LIMIT F 6.7000 F 22.00 F 30.0 17.00 F 200.0 NOL NOL NOL 98/04 6.3666 3.54 4.4 .10 10.2 160.000 9.23 98/05 6.0000 3.93 4.7 .10 26.1 173.000 8.39 98/06 5.4466 4.03 4.1 .10 23.3 95.909 8.06 1 98/07 5.1741 4.22 5.0 .10 21.1 150.434 7.82 98/08 5.0935 4.08 4.7 .10 28.1 114.285 7.96 98/09 4.8233 6.19 10.0 .10 54.6 156.666 8.16 1 98/10 4.8838 6.51 7.2 .10 33.1 284.318 8.25 AVERAGE 5.3944 4.08 5.8 .13 22.1 163.565 9.01 1 MAXIMUM 9.8000 11.70 26.0 4.90 4400.0 1145.000 14.00 1 MINIMUM 3.8000 2.00 2.0 .10 1.0 30.000 5.60 1 UNIT MGD MG/L MG/L MG/L #/100ML UG/L MG/L PASS/FAI GKEX88/MP 12/03/98 COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 2 PERMIT--NC0037508 PIPE--001 REPORT PERIOD: 9711-9810 LOC --- E FACILITY--MOORE CO WWTP DESIGN FLOW-- 6.7000 CLASS--4 LOCATION--CARTHAGE REGION/COUNTY--06 MOORE 00010 00400 00600 00665 00720 01042 01077 01092 MONTH TEMP PH TOTAL N PHOS-TOT CYANIDE COPPER SILVER ZINC LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL NOL 97/11 19.00 7.6-6.9 15.080 2.1000 .0000 10.0000 .0000 27.5000 LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL NOL 97/12 16.45 7.4-7.0 17.800 1.8700 .0000 10.5000 .0000 23.5000 98/01 15.55 7.7-6.8 13.500 1.4000 .0000 8.0000 .0000 21.0000 98/02 14.60 7.8-7.3 11.000 1.6500 .0000 9.0000 .0000 21.5000 98/03 15.77 7.9-7.1 15.250 1.3700 .0000 8.0000 .0000 19.0000 LIMIT NOL 9.0 6.0 NOL NOL NOL NOL NOL NOL 98/04 18.47 7.9-7.4 8.130 2.4000 .0000 7.5000 .0000 19.5000 98/05 20.95 7.9-7.4 14.250 2.0500 .0000 11.0000 .0000 26.0000 98/06 23.90 7.9-7.3 12.760 2.2600 .0000 8.5000 .0000 20.0000 98/07 25.87 7.8-7.1 21.140 2.7000 .0000 10.0000 .0000 21.5000 98/08 26.09 7.8-7.4 15.170 1.9500 .0000 6.5000 .0000 21.0000 98/09 25.63 7.9-7.4 17.310 2.0200 .0000 10.0000 3.0000 25.0000 98/10 22.96 7.9-7.1 14.630 1.5900 .0000 7.5000 .0000 19.0000 AVERAGE 20.43 14.668 1.9466 .0000 8.8750 .2500 22.0416 MAXIMUM 27.00 7.900 21.140 2.7000 14.0000 6.0000 33.0000 MINIMUM 14.00 6.800 8.130 1.3700 6.0000 17.0000 UNIT DEG.0 SU MG/L MG/L UG L UG/L UG L UG/L --A�oczF (Watzz cSEUTEz c ut�Zozit , .-:� Water Pollution Control System R O. Box 813 Pinebluff, North Carolina 28373 0.0 WASA OFFICE OF SYSTEM SUPERINTENDENT a 041 October 19, 1998 Mr. Ferrell Keough State Engineering Review Group N.C. Dept. of Environmental Health & Natural Resources Division of Environmental P.O. Box 27687 Raleigh, N.C. 27611 Dear Mr. Keough: Re: 2" Force Main Sewer to serve Cameron Automotive - Moore County TELEPHONE, 910-281-3146 FAX: 910.281-2047 E-mail: mowaaa2Qncpines.net The Moore County Regional WWTP hereby agrees to conditionally accept up to 500 gallons per day of wastewater from the above referenced project in accordance with the request of letter of October 6, 1998 from Nelson Consulting, Inc. Civil Engineers - Pinehurst, N.C. 28374. Upon completion of the referenced project, the applicant's engineer is to provide this office with the following items: 1. Infiltration in gallons per day 2. Certification of completion as defined by N.C. Statutory Requirements #143-215.1; Section 2-H.0200. After Moore County has received a copy of the certification of completion, our office will provide a final acceptance statement. If you have any questions or comments concerning the reference, please do not hesitate to call me at 910-281-3146. Sincerely, MOORE WATER AND SEWER AUTHORITY �- I Gary Frick System Superintendent PC: Mr. Jim Tarnow, P.E., Moore Water and Sewer Authority Mr. David Harris, Executive Director, MOWASA Mr. W. David McNeill, Jr., Moore County Manager Mr. Paul Rawls, Regional Supervisor, DEM, Fayetteville, N.C. Mr. Eric B. Nelson, Jr., P.E. Nelson Consulting, Inc. Pinehurst, N.C. Nelson Consulting, Inc. Civil Engineers 300 Ampersand Road - PO Box 5889 - Pinehurst, NC 2837 910-295-1703 October 6, 1998 Mr. Gary Frick, System Superintendent `+ Moore Water and Sewer Authority / P.O. Box 318 Pinebluff, NC 28373 RE: 2" Force Main Sewer to serve Cameron Automotive Moore County Dear Mr. Frick: r�4�e Enclosed you will find a copy of the non -discharge application and a set of plans for the referenced project. This project will produce 500 GPD of wastewater flow to the Moore Water Pollution Control Facility in Addor. Please forward a copy of the acceptance letter, addressed to the NCDENR as indicated below, to our office upon your accepting this flow at the treatment facility in Addor: State Engineering Review Group N.C. Dept. of Environment and Natural Resources Division of Environmental Management P.O. Box 27687 Raleigh, NC 27611 Should you have any questions or co ents with regard to this project, do not hesitate to contact our office. CC, Sincerely, �Cov� Eric B. Nelson Jr., P.E. Nelson Consulting, Inc State of North Carolina -`'- Department of Environment, Health and Natural ResouFees ., Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL)�� GRAVITY SEWER EXTENSION, PUMP STATIONS, AND PRESSURE SEWERS I. GENERAL INFORMATION: SOC Project: Yes, No. 1. Applicant's name (please specify 'the name of the municipality, corporation; individual, etc.): CAM 6 2 o.J %J -V-0 0T %mil 5-- 2. Print Owners or Signing Official's name and title (the person who is legally responsible -for the facility and its compliance): M o •.�l1as A 3. Mailing address: t 0 Z'1 City: State: V_A C_ Zip: Zt33z'1 Telephone Number: ( t o ) 't A--7 - (.,,315 4. Project Name (please specify the name of the subdivision, facility, or establishment - should be consistent with project name on plans, specifications, letters of flow acceptance, Operational Agreements, etc.): G gyp„ M EQ� 1►1 Q v TO tA 0 T- W 5. Application Date: 1 z - 016 6. Fee Submitted: S 6. County where project is located: tit O o C2E II. PERMIT INFORMATION: 1. Application No. (will be completed by DEW �,� 1. ` IN �0 ` Q - 2. Specify whether project is: new; modification. 3. If this application is being submitted as a result of a modification to an existing permit, please complete: existing permit number and the issue date 4. Specify whether the applicant is X public or private. III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater. I o o % Domestic/Commercial ; % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: 3. Indicate any parameter(s) (and their concentration) that will be greater than normal domestic levels: gyp` 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? tJ /A 5: If a pretreatment permit is required, has one been issued? pretreatment permit. If No, when will one be issued: /A FORM: GSPSA 02/95 Page 1 of 8 Yes No. If yes, please attach a copy of the A Volume of wastewater generated by this project: 5'00 gallons per day 7. Explanation of how wastewater volume was determined: 6 0 C C-.-.) d r 7—s/ 0 A-.Z, K Z ema. L- /0�..� ) F wAtirLy�cA.rEcL Eratg�NE��l�1L'1 Gat LGc�T�o.+ p►�.an PJwi(�1r—�� P%I��LAL� C.IJOEofl%V IV. DESIGN INFORMATION: 1. Brief project description: Seve-1 ssoC-15J OF�<<- r� SQP-DES OLSo Tw.o /�.00.r,oNA.L. Orrr,cr� t-FdasE SPA�.E.4. 2. Name of wastewater treatment facility receiving wastewater: M o.t..lASl�- A-OAosz- a. Facility Permit Number: b. Engineer should provide statement of his evaluation of downstream sewers ability to accept the wastewater: c. Permit Number for sewers immediately downstream: r d. - Pipe diameter of sewers immediately downstream: 3. Summary of GRAVfTY SEWER to be permitted, by diameter, length and pipe material: Diameter (in) Length (linear feet) Pipe Material Circle C or N Factor & Specify Value Minimum Slope (%) Maximum Slope (%) Minimum Velocity (fps) Maximum Velocity (fps) Minimum Cover (in) NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. For private sewers the minimum diameter is 6 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be a maximum of: 36 foo separation for slopes of 21% to 35%; 24 foot separation for slopes of 36% to 50%; 16 foot separation for slopes grease: than. 50%. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers an( manholes from erosion. For velocities greater than 20 fps, erosion control treasures must be specified. For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protec the sewer pipe and manholes? 5. Maximum length of sewer between manholes: 6. This sewer line segment occurs between manhole no. linear feet. and manhole no. FORM: GSPSA 02/95 Page 2 of 8 7. Does the owner/operator have the ability to clean this length? Yes No. For sewer reach lengths greater than 425 feet, please provide a letter from the owner/operator, stating the ability to clean the specified reach and include the equipment specifications. 8. Sewers subject to existing or planned traffic bearing loads? y— Yes No. If yes, what measures are being taken to(enable the sewers to withstand the loads? VJc-'C-% k¢or.► v�J�`.`. PjE �T�L�%Eo J��E� �vtit�C�E�Z LA 9. Outside drop manholes are provided where invert separations exceed: feet (provide for separations > or = 25) 10. Identify (by manhole number) those manholes that have drop connections: 11. Maximum allowable infiltration/exfiltration test rate: NOTE: Must not exceed 100 GPD/pipe diameter inch/mile of pipe. GPD/pipe diameter inch/mile of pipe. 12. Minimum separation distances as shown on the plans and addressed in the specifications. If a, b, or c below is no, explain in an attachment (This section must be completed for all collection systems including force mains and pressures sewers): a) 100 ft. horizontal separation from wells or other water supplies? _2L Yes ' No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? X Yes No c) 10 ft horiz. sep. from water mains or 18 in vertical sep. (water over sewer) or ferrous pipe specified? X Yes No 13. Are manholes subject to flooding? Yes X No. If Yes, are manhole rim elevations 1 foot above 100-year flood level, (100 year flood elevation should be indicated on plans)? Yes No; Or, are the manholes watertight, venter 1 foot above the 100-year flood elevation and vented every 1,000 feet (should be shown on plans)? Yes No. 14. Identify (by manhole number) those manholes that are vented: 15. Does this project involve any stream crossings? X Yes - No. If yes, what precautions or special features have beer utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: k ► ;E a1-7) 3 s . V ►-i O E z 5 c^� EO.M C- o S S r ► L� �`� �' E P` tsr.1 / �%►O �� �.E SN'Pc E_T SZ-p, . ; \ %-_J J. %— Please note: The Division recommends all stream crossings be located three (3) feet below the stream bed or ferrou: material pipe be specified. In addition, all aerial stream crossings must be located above the 25-year flood elevation. Bod the 25-year flood elevation and the 100-year flood elevation should be indicated on the plans. 16. Sewers may not be installed in WS-I watersheds. Are any of the subject wastewater collection systems located in a WS- watershed? Yes _ <' No. FORM: GSPSA 02/95 Page 3 of 8 V . PUMP STATION INFORMATION Pump Station No. or Name: k (A separate page 4 of 8 should be submitted for each pump station) 2. Name of closest downslope surface waters: ►-4 i c—V— S C--e-i=_EK 3.. Classification of closest downslope surface waters: W s ^� (as established by the Environmental Management Commission & specified on sheet 5 of 8 of this application). 4. In accordance with 15A NCAC 2H .0219 (h)(3), describe the measures that are being implemented to prevent impacts on downslope surface waters, should a power failure occur at this pump station. NOTE: Alternative power MUST be addressed for every pump station in accordance with the above regulation. 5. What size pumps are provided: C Z ti� e � Z.m GPM; and how many? Z 6. What is the design total dynamic head? a 5 feet 7 How many pumping cycles will occur at average daily flow? Z cycles per hour. NOTE: 15A NCAC 211.0219 (h)(2) requires 2 to 8 pumping cycles per hour be achieved at average daily flow. 8. The following items are typically required in the design for pump stations. Check the appropriate blank to signify that these items hayr, lx&n provided in the design plans and specifications: - Alternate Power Source Wet Well Vented with Screen Fillets in Wet Well Check Valves and Gate Valves Security Fencing Lockable Wet Well Cover Area Light 110V Electrical Convenience Outlet Flood/Buoyancy Protection High Water Alarm (one choice may be specified) Audible and Visual Auto Dialer 9. Summary of FORCE MAIN or PRESSURE SEWER to be permitted, by diameter, length and pipe material: Diameter (in) Length (linear feet) Pipe Material . High Elevation (ft) Low Elevation {ft) Minimum Velocity .( ) Maximum Velocity (fps) Minimum Cover (in) Z 3z3 ► F.eC 142.co 10. Are air release valves provided at all high points along the force main (must be provided where the elevation difference exceeds 10 feet)? x Yes —No 11. Is the pump station subject to flooding? _ Yes K No. If Yes, what measures are being taken to protect against flooding 12. If subject to flooding, specify the 100-year flood elevation: r-tlP- Feet MSL 13. Are there existing or planned pump stations downstream of this station? Yes X No. If Yes, the enginee shall evaluate the ability of those pump stations to adequately handle the subject flows and shall include that evaluation a an attachment to this application. FORM: GSPSA 02/95 Page 4 of 8 This form must be completed by the appropriate DEM regional office and included as a part of the project submittal information. INSTRUCTIONS TO NC PROFESSIONAL ENGINEER: The classification of the downslope surface waters (the surface waters that any overflow from the facility would flow toward) in which these sewers will be constructed must be determined by the appropriate DEM regional office. Therefore, you are required, prior to submittal of the application package, to submit this form, with items 1 through 7 completed, to the appropriate Division of Environmental Management Regional Water Quality Supervisor (see page 8 of 8). At a minimum, you must include an 8.5" by 11" copy of the portion of a 7.5 minute USGS Topographic Map which shows the location of these sewers and the downslope surface waters in which they will be located. Identify the closest downslope surface waters on the attached map copy. Once the regional office has completed the classification, reincorporate this completed page and the topographic map into the complete application form and submit the application package. 1. Applicant (specify name of the municipality, corporation, individual, etc.): 2. Name & complete address of engineering firm: P-A 0,t4 ,4,, S A Ql.-S �..�?Er-►TEJ�L.S � NEL-So tJ Telephone number. ( I I I ) Z 9 aV- o J. Project name: G r�-t-�1 r-► L`.� ro vt o-r t.sE 4. Name of closest downslope surface waters: t-1 %ems ' s L¢-E v-- t 5. County(ies) where sewers and surface waters are located: 6. Map name and date: 7. NC Professional Engineer's Seal, Signature, and Date: TO: REGIONAL WATER QUALITY SUPERVISOR Please provide me with the classification of the watershed where these sewers will be constructed, as identified on the attachec map segment: Name of surface waters: Classification (as established by the Environmental Management Commission): Proposed classification, if applicable: _ Signature of regional office personnel: Date: FORM: GSPSA 02/95 Page 5 of 8 THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUB1xITTAL Required Items a. One original and one copy of the completed and appropriately executed application form. If modifications to the form are required as a result of additional information requests by the Division, the additional information must be transmitted under the signature of the applicant and the actual modification must be initialed by the NC Professional Engineer. b. Two (2) sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the First page of the specifications must be signed and sealed. Two (2) copies of the existing permit if a- modification. The plans and specifications must not contain phrases (such as: FOR REVIEW ONLY, NOT FOR CONSTRUCTION, etc.) that indicate that they are anything other than final plans and specifications. However, the plans and specifications may contain: FINAL DESIGN - NOT RELEASED FOR CONSTRUCTION. C. Two copies of all calculations, including pump selection, friction calculations, cycle time, pump curves (including system curves applicable with one pump running, two pumps running, three pumps running, etc.), and evaluation of downstream pump stations. These items must be submitted under the signature and seal of the NC Professional Engineer. A The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). The fee for sewer extensions for nondelegated municipalities is $400. The fee for sewer extensions for delegated municipalities (applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Environmental Managemew Commission) is $200. Name changes without other modifications are $100. e. If the owner/authority of the wastewater treatment facility (W W IFS that will be accepting the wastewater flow from tliii project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. f. If the application is being submitted in the name of a privately owned public utility, evidence must be submitted from tht Utilities Commission which demonstrates that the utility is authorized to hold the franchise for the area to be served. In the case of contiguous service areas, evidence must be provided from the Utilities Commission acknowledging these areas air covered under an existing franchise. g. A properly executed Operational Agreement (original and two copies - form provided by DEM) must be submitted if the sewe extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewe extension is owned by the individual residents, a homeowners association, or a developer. h. The downslope surface waters classification must be determined by the appropriate DEM regional office, using page 5 of 8 c this form, prior to the submittal of the application package to the Water Quality Permits an, Engineering Unit. Once the regional office has completed the classification, page 5 of 8 should be reincorporated into th application package and the entire application package may then be submitted to Water Quality Permits and Engineering Uni i. A cover letter, which briefly describes the project, should be included with each application package. If necessary for clarit: feel free to include attachments to the application form. Such attachments will be considered as part of the application an should be numbered to correspond to the section to which they refer. All materials and fees submitted in support of this request for a permit become the property of the Division of Environment: Management; therefore, if the permit is not issued for any reason, the Division will return submitted materials only at i option. FORM: GSPSA 02/95 Page 6 of 8 Name and Complete Address of Engineering Firm: ti-�E �-S�" C-o ►---x %►--LL-t , \'. 30o L�►MPE�SA,. �0 �-o�o - ��� Sox 5889 , mac- 2-8374; City: L�.P�� Q.OeE�--► State: N C- Zip: Z-2> S Telephone Number. ( cr\ \ c ) Z,:2tS - 1-103 Professional Engineer's Certification: I, C r►c- (� )�G �SoV� Tv {, attest that this application for 6Zwte-~ Ay�f'"// 7ye- has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Seal, Signature, and Date: C�AjR�0���`// N o.. Fess�a •ti i _ ; a SEAL r 20208 Applicant's Certification: I, attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Signature Date THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: (919) 733-5083 FORM: GSPSA 02/95 Page 7 of 8 DIVISION OF ENVIRONMENTAL MANAGEMENT REGIONAL OFFICES (12194) Asheville Regional WQ Supervisor 59 Woodfin Place Asheville, NC 28801 (704) 251-6208 Fax (704) 251-6452 Avery Macon Buncombe Madison Burke McDowell Caldwell Mitchell Cherokee Polk Clay Rutherford Graham Swain Haywood Transylvania Henderson Yancy Jackson Fayetteville Regional WQ Supervisor Wachovia Building, Suite 714 Fayetteville, NC 28301 (910)486-1541 Fax (910) 486-0707 Anson Moore Bladen Robeson Cumberland Richmond Harnett Sampson Hoke Scotland Montgomery Washington Regional WQ Supervisor Post Office Box 1507 Washington, NC 27889 (919) 946-6481 Fax (919) 975-3716 Winston-Salem Regional WQ Supervisor 585 Waughtown Street Winston-Salem, NC 27107 (910) 77146W Fax (910) 771-4631 Alamance Rockingham Alleghany Randolph Ashe Stokes Caswell Surry Davidson Watauga Davie Wilkes Forsyth Yadkin Guilford Beaufort Jones Bettie Lenoir Camden Martin Chowan Pamlido Craven Pasquotank Currituck Perquimans Dare Pitt Gates Tyrell Greene Washington Hertford Wayne Hyde Mooresville Regional WQ Supervisor 919 Norff Main Street Mooresville, NC 28115 (704) 663-1699 Fax (704) 663-6040 Alexander Mecklenburg Cabar us Rowan Catawba S tanly Gaston Union Iredell Cleveland Lincoln Raleigh Regional WQ Supervisor Post Office Box 27687 Raleigh, NC 27611 (919)571-4700 Fax (919) 571-4718 Chatham Nash Durham Northampton Edgecombe Orange Franklin Person Granville Vance Halifax Wake Johnston Warren Lee Wilson Wilmington Region. WQ Supervisor 127 Cardinal Drive Extension Wilmington, NC 28405-3845 (910)395-3900 Fax (910) 350-2004 Brunswick New Hanover Carteret Onslow Columbus Pender Duplin FORM: GSPSA 02/95 Page 8 of 8