Loading...
HomeMy WebLinkAboutWQ0011746_Application_19951207State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director December 4, 1995 1: D E F1 Mr. David M. Harris, Executive Director Moore Water and Sewer Authority P.O. Box 1927 Carthage, North Carolina 28327 (C)EI Subject: DEC 7' W za Dear Mr. Harris: Application No. WQ0011746 Additional Information Request Moore Water and Sewer Authority Pinehurst #8, Clubhouse Utilities Sewer Extension Moore County The Permits and Engineering Unit has completed a preliminary engineering review of the subject application. Additional information is required before we can continue our review. Please provide the following by January 4, 1995: * On sheet 2 of 5 of the application, the length of gravity sewer to be permitted was left off. Please calculate the length of sewer line to be permitted and send the revised sheet of the application to my attention. This revised sheet of the application should be individually signed and sealed. * The Division's regulations stipulate that three feet of minimum cover must be maintained over the sewer line or that a pipe'of ferrous material should be used. Between manholes 1 and 2 and between manholes 3 and 5, there are areas which do not maintain three feet of minimum cover and are listed as PVC sewer. Please bring these portions of the sewer into compliance with the Division's regulations. * The Division's regulations stipulate that when sewer-, cin not maintain a 10 Fart bnn7ontal separation with water mains that an 18 inch vertical separation (water over sewer) shall be maintained or that a pipe of ferrous material shall be used. The note on the plans, regarding the separations to be maintained between water mains and sewer mains, needs to reflect that the 18 inch separation only applies when the water main is crossing over the sewer main. * The specifications submitted for this project mention the relocation of a pump station. The Division needs to know where this pump station is located to determine if permitting is required for this pump station and its associated force main. If there is no pump station to be relocated, please resubmit the revised specifications without the sections on the pump station and force main. P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper Please reference the subject permit application number when providing the requested information. All information should be signed, sealed, and submitted in duplicate to my attention at the address below. Please submit two complete sets of the revised plans. Please note that failure to provide this additional information on or before the above requested date can result in your application being returned as incomplete. If you have any questions regarding this request, please call me at (919) 733-5083, ext. 527. Sincerely, Rick Moore Environmental Engineer State Engineering Review Group cc: Fayetteville Regional Office Permit File WQ0011746 Hobbs. Upchurch and Associates