Loading...
HomeMy WebLinkAboutWQ0011170_Application_19950615• State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director June 15, 1995 MR DAVID HARRIS MOWASA PO BOX 1927 CARTHAGE, NORTH CAROLINA 28327 Dear MR HARRIS: A4� C) FE F9t JUN Subject: Application No. WQ0011170 Pinewild Phase III, Seciton VI Sewers -Public Moore County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on June 14, 1995. This application has been assigned the number listed above. PLEASE REFER TO THE ABOVE WATER QUALITY NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. 10 Your project has been assigned to Randy Kepler for a detailed engineering review. Should there be any questions concerning your project, the reviewer will contact you with an additional information letter. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Randy Kepler at (919) 733-5083 extension 544. If the engineer is unavailable, you may leave a message on their voice mail and they will respond promptly. Please reference the above application number when leaving a message. Sincerely, Caro yn M askill Supervisor, State Engineering Review Group a. nECEIVE) cc: Fayetteville Regional Office Hobbs Upchurch & Associates JUN 1 is 1995 Pollution PreventionGGPAM MANAGEMENT � P.O. Box 29535, Raleigh, North Carolina 27621� 4fVU*J*@JWMA5 An Equal Opportunity Affirmative Action Employer MEMO TO: State Review Group Division of Environmental Management FROM: Ricky Revels R` R`""4� Fayetteville Regional Environmental Technician IV Office SUBJECT: Procedure Four (4) 8 07 95 WQ0011170 Date Pinewild Phase III, Sec. 6 Sewer Extension - Public MOWASA/Village of Pinehurst Moore County State Review Group Review Engineer Randy Kepler Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: Moore County Regional Wastewater Treatment Plant 2) WWTP design capacity 6_7 MGD 3) NPDES Permit No.: NCO037508 Expiration Date: 4 30 97 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 7 94 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 14.040 GPD domestic 100% industrial other 6) Volume from previously approved projects not yet tributary to WWTP 1,302,852 GPD 7) Regional Recommendations: Approval X Denial RR/rr Enclosure . . ` . ZISSION READY FCR !XPo7CKEX88/MP COMPLIANCE EVALUATION ANALYSIS REPOR'',,' PERMIT--NC0037508 PIPE--001 REPORT PERIOD, 9407-9506 LOC---� FOCILITY--MO3RE COUNTY WYTP DESIGN FLOW-- 6.7000 LDCPTTJN--CARTHA�E REGION/CGUuTY--46 MOORE. ^ -- r'-��� � ' .58050 00510 00500 vA6i0 31616 50060 0030, TGp3B �ONT� B/HGD BOD RE%/T%% NH3+Np4- "EC COLT CHLORINE DO CER17DPF LIM7T F 6.7000 F 22.00 F 38.0 17.00 F 200.0 94/07 4'4064 3.ii 4.6 NDL KGL KC' 94/02 ^ 4.2071 3 �3 � 4 .iO 35.6 34.000 94/09 4.8790 4.81 ^ ^ 7.8 .10 .i0 23.2 iO4.i f42.272 8.05 3 94/10 4.2322 6.13 9.2 .i6 99.4 164.428 8.57 i LAMAT F 6.7000 F 30.00 F 38.0 kUL F 209.0 NOL F4/12 4.5516 6.23 12.3 .>5 42.2 i62.500 i 6.7000 F 30.00 F 30.6 KGL F 200.0 NGL HGL 7.2i 3.7 .23 7.4 236.500 9.46 NO! ;3/83 :1074i 7.3� F.3 10 22.5 60.169 �IHIT F 6.7000 F 22.09 F 30.0 17.00 F 200.0 Np' '5/04 4.3?3z 5.35 4.5 .21 33.? 61.57� KGL �.06 NGL /5/85 4.i4i9 4.57 3.6 .10 20.1 70.454 9.!4 `YERABE 4.442i 5.46 7.6 !oXIMUM 8.5000 .13 44.0 111.675 3 93 � 17.60 10.6 1.73 i5000.0 i600^O00 |INIHUM ��.8000 2.00 2.0 i3^50 3 .iO 2.0 30^000 6^i0 i WIT MGD MC/L MG/L M[/L 4/100HL �C/L M^/L PA%%/FA� . . ^ ' GKEX88/MP COMPLIANCE EVALUATION ANALYSIS REPORT OG/O7/95 PAGE 2 PERMIT--NC0037508 PIPE--00i REPORT PERIOD: 9407-9586 LOC --- E FACILITY--MOORE COUNTY WWTP DESIGN FLOW-- 6.7000 LOCATION--CARTHAGE REGION/COGNTy--06 MOORCLA%%--4 00810 00400 00600 00665 00720 0i027 0034 0iO42 MONTH � TEMP PH TOTAL N PHO%-TOT CYANIDE CADMIUM CHROMIUM COPPER LIMIT NOL 9.0 6.0 NOL NGL 94/07 24.50 8.0-7.2 15.400 2.2800 .0000 NCL .0000 KGL KGL 4.500O .0000 94/0F 24.1; 8.0-7.5 16.909 2.0000 .0000 .f300 .00O0 14/G9 23.61 / 7-7.3 i5.700 i.5408 0000 .0001 .GOOD 154500 94/10 21.28 8.4-7.3 15.808 2.00GO .0000 .0000 .0000 .!MIT 7o/K NOL 9.0 6.0 NOL NOL NOL NOL NOL 20.63 8.1-7.2 20.600 2.6000 ?4/i2 18.00 7.7-7.} :3.69O 2.2000 .O000 ii.50�� !HIT 15/0 NOL 9.0 6.0 NSL NEE NOL NOL NOL NOL 15^0 5.1-7.5 17.600 2.1050 15/02 i4.10 7.8-7.1 20.700 2.2000 .0�OO i3.0066 15/o3 16.52 7.9-7.4 T?.600 1.6500 WIT � NOL 9.0 6'0 NOL NOL �OL '5/0, i8.72 7.E-7 7 15.400 NOL NOL HO� 2.3000 , �/05 2W3 7.7-7 2 20.?00 2.5000 �O00 4.�080 .VERAW i9.86 i7.472 2.ii72 'AXIMUM ---- 26.0� 8.400 20 9�0 2 6000 .0��� ^ O000 ^ 0000 ^ '0 �4�4 INIHUM 12.00 7.i00 ^ ^ 13,600 ^ 15400 ^ -- ----- -------- -------- 17^0000 HIT BEG.0 %U MG/L MA/L ----i... uG/L -------- UG/L ------- ^ UG/L Ub/L . , GK�XGG/MP COMPLIANCE EVALUATION ANALYSIS REPORT PAGE 3 PERMIT--NC0037508 PIPE--901 REPORT PERIOD' 9407-9506 LOC---E FACILITY--MOORE COUNTY WWTP DE%IGN FLOW-- 6.7000 LOCATION--CARTHAGE REGIGN/CGUNTY--06 MOORf� - 095i 01067 01077 0042 Oii47 0906 MONTH �,� `LGAD NICKEL SILVER ZINC SELENIUM MERCURY .' LINIT NOL NOL NOL KGL NOL 94/07 .0000 .0000 .0000 15.5000 .0000 .O000 94/0s .0080 .0000 .0000 20.1000 .0000 .0000 94/09 .0000 .0000 .0000 29.5000 .0000 W00 .0000 .0000 .0000 30.0500 -IMIT NOL NOL NOL NOL NOL 94/1� .0060 44.5000 1421.0500 34.000� y5/�3 3.3333 23.O000 'I577 NPi� 5 L NGL .6500 1 V.7 0�0 5.7121 26.5200 1AXIHUH __------ ------_ 62.0000 47.0000 OHIHUM -------- -------- i5.6wwO �HIT QG/L UG/L UG/L UG/L UG/L -���� State of North Carolina Department of Environment, Health, and Natural Resources Cn Division of Environmental Management Non -Discharge Permit Application: (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) -- GRAVITY SEWER EXTENSION' I. GENERAL INFORMATION: '- o 1. Applicant (corporation, individual, or other): MoWASA 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): David Harris, President 3. Mailing Address: PO Box 1927 City: Carthage State: NC Zip: 28327 Telephone No.: ( 910 ) 947-6315 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): Pinewild Phase III Section,6 5. Application Date: April 28, 1995 6. Fee Submitted: $ 400.00 7. County where project is located: Moore H. PERMIT INFORMATION: 1. Permit No. (will be completed by DEM): Q og 2. Specify whether project is: new; renewal*; X modification. *If renewal, complete only sections I through III and applicant signature (on pg.5). Submit only pgs. 1, 2, 5 (original and 3 copies of each). Engineer signature not required for renewal. 3. S If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit number WQ0009569 and issue date 12-22-94 Specify whether the applicant is X public or private. FORM: GSEA 4/91 Page 1 of 6 GRAti SEWER EXTI NSION PAGE , /91) III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater. ion % Domestic; % Commercial; % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: Single Family Residences 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: NIA 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? 5. Volume of wastewater generated by this project: 14,040 gallons per day 6. Explanation of how wastewater volume was determined: 39 lots served -x 360 GPD per lot = 14,040 GPD IV. DESIGN INFORMATION: 1. Brief project description: 7961 LF of 8" gravity sewer main and 40 manholes 2. Name of wastewater treatment facility receiving wastewater: a. Facility permit no.: NC 0037508 b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: The down stream sewer are sized adequately to 2of6 pGRAE l SSEWER EXTENSION 3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C factor or N factor is used and circle C or N below: N Dia. Length Pipe C or N Min. Max. Minimum Max. Minimum (In.) (Lin. Ft) Material Factor Slope % Slope % Velocity (fps) Vel.(fps) Cover (in) 10" 550 D.I.P. 0_012 .22 .12 2.1 2.1 n1-h" R" 5?n1 pvr. 0.01 _4n 8 12 2.3 1n.00 31-8io NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be as follows: a. 36 feet separation for slopes of 21% to 35%; b. 24 feet separation for slopes of 36% to 50%; c. 16 feet separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified. For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? 5. Maximum sewer reach length between manholes: 359.98 linear feet. 6. This sewer line segment occurs between manhole no. 36 and manhole no. 37 7. Does the owner/operator have the ability to clean this length? X Yes No. 8. Sewer subject to existing or planned traffic bearing loads? X Yes No. If yes, what measures are being taken to enable the sewers to withstand the loads? Adequate bedding, compactions and depth 9. Outside drop manholes are provided where invert separations exceed: 2.01' feet. 10. Identify (by manhole number) those manholes that have drop connections: Manhole's 4i .5, 8 & 9 3of6 GRAVT ry SEWER EXTENSION PAGE 191) 11. Maximum allowauie infiltration/exfiltration,test rate: Note: Must not exceed 200 GPD/ pipe dia. in./ mile. GPD/ pipe dia. in./ mile. 12. 13 14 I&I Minimum separation distances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? -L Yes _ No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? c) 10 ft. horizontal separation from water mains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? Are manholes subject to flooding? If yes, are manhole rim elevations 1 foot above 100-year flood level, (100 year flood elevation should be indicated on plans) Or are manholes watertight and vented 1 foot above the 100-year flood elevation ( should be shown on plans): 16. Identify (by manhole number) those manholes that are vented: bi I e Yes —No X- Yes _No _Yes FL No Yes No _Yes —No 17. Does this project involve any stream crossings? y- yes _ no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: adequate deep below stream bottom. THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and three copies of the completed and appropriately executed application form. b. Three sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or modification. C. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). d. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. e. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 4of6 ♦ i ' GRAB 'SEWER EXTENSION PAGE 5 (4/91) Name and Complete Address of Engineering Firm: Hobbs, Upchurch & Associates, P.A. PO Box 1737 / 290 S.W. Broad St. City: Southern Pines State Telephone No. 910/692-5616 Professional Engineer's Certification: NC Zip: 28388 I, _David T. Upchurch , attest that this application for Pinewild Phase III Section, 6 has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Registration No. Print Name of Engineer David T. Seal and Signature (specify date) Applicant's Certification: 9570 a+,n, •: `a�•.•OFESSio`"' fQ� A f 70 o 9 ' '*GIN 0r Vim: I, David Harris , attest that this application for Pinewild Phase III Section 6 has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and at hments are not included, this application package will be returned as incomplete. Signature Date THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: 919/733-5083 5of6 GRAY SEWER EXTLNSION PAGE '91) PERMIT APPLICATION PROCESSING FEES (effective October 1, 1990) CATEGORY > 1,000,000 GPD Industrial Domestic/Cooling Water 10,001 - 1,000,000 GPD Industrial Domestic/Cooling Water 1,001 - 10,000 GPD NEW APPLICATIONS/ MODIFICATIONS Industrial $400 Domestic/Cooling Water $400 < or = 1,000 GPD and, Single Family Dwelling $240 RENEWALS WI'I'f-IOUT MODIFICATIONS $300 $300 $250 $250 $200 $200 $120 Sludge < or = 300 Acres $400 $250 Sludge > 300 Acres $400 $250 Sewer Extensions (nondelegated) $400 0 Sewer Extensions (delegated) $200 0 Closed -Loop Recycle or Evaporative $400 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer Extension Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Division of Environmental Management. 6of6 State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director June 20, 1995 Mr. David Harris, President Moore Water and Sewer Authority P.O. Box 1927 Carthage, NC 28327 Dear Mr. Harris: ALTI.K;VA 7400 Iv-iN F� CEIVED� JUN 26 1 ENV. MANAGEMENT FAYETTEVILLE RE& 1113M. Subject:. Application No. WQ0011170 Additional Information Request MoWASA Pinewild Phase III, Section 6 Sewer Extension Moore County The Permits and Engineering Unit has completed a preliminary engineering review of the subject application. The following items must be addressed before we can complete our review: 1. On February 1. 1993, the Division adopted new regulations that require that the infiltration/exfiltration rate must not exceed 100 GPD per inch of pipe diameter per mile of pipe. All sewer extension permit applications received on or after February 1, 1993, must conform to these new regulations. Please revise page SP-9 of your gravity sewer specifications to reflect these changes and correct on page 4 of 6 of the submitted application (0-Aeue-ftwol-11"T"'11). Please be advised that the Division has my6ed Ote pplication €ermsrto-re€leet -- the new regulations. If you do not have a copy, please call and the newest version will be sent to you. 2. Please provide confirmation for the approval (401 certification) for the sewer line construction through the wetlands shown of the submitted plans. Refer to the subject permit application number when providing the requested information. Please submit two (2) copies of all information to my attention at the address below. Also, please note that failure to provide this additional information on or before July 20, 1995 will subject your If you have yan questions on this matter, please calme at (919) 733-5083 ext. 544. Sincerely, Randy L. Kepler Environmental Engineer State Engineering Review Group cc: Fayetteville Regional Office, Water Quality Hobbs, Upchurch, and Associates, P.A. Permit File WQ0011170 P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director June 5, 1995 MR DAVID HARRIS MOORE COUNTY WATER & SEWER AUTHORITY PO BOX 1927 CARTHAGE, NORTH CAROLINA 28327 Subject: Dear MR HARRIS: JUN 12 i;:,_ ENV. MANAGEMENT FAYETIFEVILLE REG. OFFICE Return of Incomplete Application Pinewild Phase III Section 6 Sewers -Public Moore County In accordance with Division policy, the enclosed application package, which was received on May 30, 1995, is being returned as incomplete.The following checked items are lacking: -Two sets of plans/specifications signed and sealed by an N.C. Professional Engineer. -Five sets of plans/specifications signed and sealed by an N.C. Professional Engineer. -Two copies of all required supporting materials. Appropriately completed and signed application form plus one copy. -Letter from current permit holder requesting name change. -Letter of flow acceptance (SPECIFYING FLOW) from owner of receiving treatment facility. This letter must be included in package when re -submitted. -Operational Agreement for sewers owned by individual residents, a homeowners association, or a developer. -Permit application processing fee of $. -Subsurface evaluation/soil scientist's report for surface and subsurface waste disposal permits, including loading rate calculations. -Waste analyses and Toxicity Characteristic Leachate ProcedurP.,(TCLP) Analysis. -Other Items: After all required submittal information has been obtained, the completed application package may be resubmitted in accordance with the submittal instructions included on the application form. Be sure to submit all originally submitted information (and copies) along with the required additional information. If you have any questions, please contact Michael Allen at (919) 733-5083, ext. 547. cc: Fayetteville Regional Office} Hobbs, Upchurch & Associates SERG Return File Sincerely, Carolyn McCaskill, Supervisor State Engineering Review Group Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 . Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer State of North Carolina _ Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director A7 16 T jai IL oE� , May 10, 1995 MR DAVID HARRIS MOORE COUNTY WATER & SEWER AUTHORITY PO BOX 1927 Subject: CARTHAGE, NORTH CAROLINA 28327 Dear MR HARRIS : OW Am 1995 ENV. MAOEMINT E` TEVIUE REe, OFFICE, Return of Incomplete Application Pinewild Pnase III Section 6 Sewers -Public Moore County In accordance with Division policy, the enclosed application package, which was received on May 8, 1995, is being returned as incomplete.The following checked items are lacking: -Two sets of plans/specifications signed and sealed by an N.C. Professional Engineer. -Five sets of plans/specifications signed and sealed by an N.C. Professional Engineer. -Two copies of all required supporting materials. ,f -Appropriately completed and signed application form plus one copy. -Letter from current permit holder requesting name change. -Letter of flow acceptance (SPECIFYING FLOW) from owner of receiving treatment facility. This letter must be included in package when re -submitted. -Operational Agreement for sewers owned by individual residents, a homeowners association, or a developer. -Permit application processing fee of $.. -Subsurface evaluation/soil scientist's report for surface and subsurface waste disposal permits, including loading rate calculations. -Waste analyses and Toxicity Characteristic Leachate Procedure (TCLP) Analysis. -Other Items: *Application page 2 IV.2 (a) and (b) must be completed. *Application IV 11, Infiltration/Exfiltration Test Rate must not exceed 100. After all required submittal information has been obtained, the completed application package may be resubmitted in accordance with the submittal instructions included on the application form. Be sure to submit all originally submitted information (and copies) along with the required additional information. If you have any questions, please contact Michael Allen at (919) 733-5083, ext. 547. cc: Fayetteville Regional Office Hobbs, Upchurch & Associates SERG Return File Sincerely, ' arolyn McCaskill, Supervisor State Engineering Review Group Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer