HomeMy WebLinkAboutSW6200403_1356-Runoff coefficient calcs_4/30/2020Fayetteville Clinton Road Dollar General Storm Water Control SCS curve number Hydraulic Soil Group :A Area SCS CN Building (sf) 9,005 98 Building (sf) 9,005 98 Pavement (sf) 23,909 98 Pavement (sf) 23,909 98 Open space (sf) 35,734 39 Pond (sf) 4,883 98 Offsite -open space (sf) 39 Open space (sf) 34,743 39 Offsite -impervious (sf) 98 Offsite -open space (sf) 39 Offsite -impervious (sf) 98 Total (sf)72540 70 Total (ac)1.67 Rational Coefficient Predevelopment Postdevelopment Area C Area C Impervious (sf) 0.95 Building (sf) 9,005 0.95 Open space (sf) 72,540 0.30 Pavement (sf) 23,909 0.95 Pond (sf) 4,883 0.95 Open space (sf) 34,743 0.3 Offsite -open space (sf) 0.3 Offsite -impervious (sf) 0.95 Total (ac)72540 0.30 Total (ac)72540 0.64 Total (ac)1.67 Total (ac)1.67 1356-Runoff coefficient calcs.xls Printed 4/30/2020