HomeMy WebLinkAboutWQ0001990_2019 Residual Annual Report Review_20200429
April 29, 2020
Greg Padgett
Town of Valdese
PO Box 339
Valdese, NC 28690
SUBJECT: Compliance Inspection Report
2019 Annual Residuals Report Review
Town of Valdese DCAR
Non-discharge Permit No. WQ0001990
Burke County
Dear Permittee:
The North Carolina Division of Water Resources conducted an inspection of the Town of Valdese DCAR
on 4/28/2020. This inspection was conducted to verify that the facility is operating in compliance with
the conditions and limitations specified in Non-discharge Permit No. WQ0001990. Please review any comments
noted in the summary of the attached inspection report.
If you should have any questions, please do not hesitate to contact me at 828-296-4686 or via email at
mikal.willmer@ncdenr.gov.
Sincerely,
Mikal Willmer, Environmental Specialist II
Water Quality Regional Operations Section
Asheville Regional Office
Division of Water Resources, NCDEQ
ATTACHMENTS: Inspection Report
EC: LF
Chris Bortnick
Compliance Inspection Report
Permit:WQ0001990 Effective:08/01/19 Expiration:06/30/24 Owner :Town of Valdese
SOC:
Contact Person:
Region:
County:
Directions to Facility:
Burke
Asheville
Seth Eckard
Effective:Expiration:Facility:Town of Valdese DCAR
2100 Lake Rhodhiss
Valdese NC 28690
Title:Phone:828-396-7903Town Manager
From downtown Valdese, take 70E to left on Laurel Street, right on Lovelady Road, left on Lake Rhodiss Dirve, WWTP is located at
the end of the road.
Secondary ORC(s):
Phone:Certification:Primary ORC:
System Classifications:
On-Site Representative(s):
Related Permits:
NC0041696 Town of Valdese - Lake Rhodhiss WWTP
Secondary Inspector(s):
Primary Inspector:
Inspection Date:Exit Time:Entry Time:
Phone:
04/28/2020 03:00PM 04:00PM
Mikal Willmer 828-296-4686
Facility Status:
Permit Inspection Type:
Reason for Inspection:Inspection Type:
Not CompliantCompliant
Routine
Distribution of Residual Solids (503)
Annual Report Review
Question Areas:
Miscellaneous Questions Record Keeping Treatment
Pathogen and Vector Attraction
(See attachment summary)
Page 1 of 4
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0001990
04/28/2020 Annual Report Review
Town of Valdese
Routine
Inspection Summary:
Mikal Willmer with the Asheville Regional Office conducted a review of the Town of Valdese's 2019 DCAR annual report on
April 28, 2020.
Facility appeared to process and monitor the residuals in compliance with Permit No. WQ0001990.
DMSDF: Please provide the weight equivalent for a "scoop" in future submittals so the total dry tons recorded on form
DMSDF can be assessed against the customer distribution log.
Fecal Coliform: Quarterly samples were collected and all appear to be less than 1000 MPN/g
Non-hazardous waste characterization: Required once per permit cycle for source residuals and final product. Facility
analyzed ignitibility, corrosivity and reactivity in 2019 for the source residuals and final product. A full characterization will be
required before the end of the permit cycle. The new permit went into effect August 1, 2019 and will expire on June 30, 2024.
Metal & Nutrients: metals and nutrient analysis appeared to be in compliance with all regulatory limits. SAR was below 10.
Metals and Nutrients analysis will be required for the source residuals before permit expiration in 2024.
Pathogen and Vector Attraction Reduction: All temperatures appeared to meet the requirements of PFRP Compost and VAR
method 14-day aerobic. Also, please ensure when assessing the 14-day start that the temperature is above 40 degrees and
not equal to 40.
Page 2 of 4
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0001990
04/28/2020 Annual Report Review
Town of Valdese
Routine
Type Yes No NA NE
Land Application
Distribution and Marketing
Record Keeping Yes No NA NE
Is GW monitoring being conducted, if required?
Are GW samples from all MWs sampled for all required parameters?
Are there any GW quality violations?
Is GW-59A certification form completed for facility?
Is a copy of current permit on-site?
Are current metals and nutrient analysis available?
Are nutrient and metal loading calculating most limiting parameters?
a. TCLP analysis?
b. SSFA (Standard Soil Fertility Analysis)?
Are PAN balances being maintained?
Are PAN balances within permit limits?
Has land application equipment been calibrated?
Are there pH records for alkaline stabilization?
Are there pH records for the land application site?
Are nutrient/crop removal practices in place?
Do lab sheets support data reported on Residual Analysis Summary?
Are hauling records available?
Are hauling records maintained and up-to-date?
# Has permittee been free of public complaints in last 12 months?
Has application occurred during Seasonal Restriction window?
TCLP analysis is required once per permit cycle for the product and feed cake. Permit renewed
in 2019 and TCLP will be due before next permit renewal. Facility had a complaint last year and
was addressed and documented in a separate inspection report.
Comment:
Pathogen and Vector Attraction Yes No NA NE
a. Fecal coliform SM 9221 E (Class A or B)
Class A, all test must be <1000 MPN/dry gram
Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram
Fecal coliform SM 9222 D (Class B only)
Geometric mean of 7 samples per monitoring period for class B<2.0*10E6 CFU/dry gram
b. pH records for alkaline stabilization (Class A)
c. pH records for alkaline stabilization (Class B)
Page 3 of 4
Inspection Date:
Permit:
Inspection Type :
Owner - Facility:
Reason for Visit:
WQ0001990
04/28/2020 Annual Report Review
Town of Valdese
Routine
Temperature corrected
d. Salmonella (Class A, all test must be < 3MPN/4 gram day)
e. Time/Temp on:
Digester (MCRT)
Compost
Class A lime stabilization
f. Volatile Solids Calculations
g. Bench-top Aerobic/Anaerobic digestion results
Comment:
Treatment Yes No NA NE
Check all that apply
Aerobic Digestion
Anaerobic Digestion
Alkaline Pasteurization (Class A)
Alkaline Stabilization (Class B)
Compost
Drying Beds
Other
Facility statically aerates compost piles to bring temperature to at least 55 degrees Celsius for
three days to meet Pathogen Reduction and above 40 degrees Celsius for 14 days to meet
Vector Attraction Reduction.
Comment:
Page 4 of 4
Certificate Of Completion
Envelope Id: 3ED66E95324A46079FF6A0F4FC7EDE7F Status: Completed
Subject: Please DocuSign: WQ0001990 Ltr.docx, WQ0001990 CEI.pdf
Source Envelope:
Document Pages: 5 Signatures: 1 Envelope Originator:
Certificate Pages: 1 Initials: 1 Mikal Willmer
AutoNav: Disabled
EnvelopeId Stamping: Disabled
Time Zone: (UTC-05:00) Eastern Time (US & Canada)
217 W. Jones Street
Raleigh, NC 27699
Mikal.willmer@ncdenr.gov
IP Address: 149.168.204.10
Record Tracking
Status: Original
Apr 29, 2020 | 13:40
Holder: Mikal Willmer
Mikal.willmer@ncdenr.gov
Location: DocuSign
Signer Events Signature Timestamp
Mikal Willmer
mikal.willmer@ncdenr.gov
Environmental Specialist
North Carolina Department of Environmental Quality
Security Level: Email, Account Authentication
(None)
Signature Adoption: Pre-selected Style
Using IP Address: 149.168.204.10
Sent: Apr 29, 2020 | 13:40
Viewed: Apr 29, 2020 | 13:40
Signed: Apr 29, 2020 | 13:41
Freeform Signing
Electronic Record and Signature Disclosure:
Not Offered via DocuSign
In Person Signer Events Signature Timestamp
Editor Delivery Events Status Timestamp
Agent Delivery Events Status Timestamp
Intermediary Delivery Events Status Timestamp
Certified Delivery Events Status Timestamp
Carbon Copy Events Status Timestamp
Witness Events Signature Timestamp
Notary Events Signature Timestamp
Envelope Summary Events Status Timestamps
Envelope Sent Hashed/Encrypted Apr 29, 2020 | 13:40
Certified Delivered Security Checked Apr 29, 2020 | 13:40
Signing Complete Security Checked Apr 29, 2020 | 13:41
Completed Security Checked Apr 29, 2020 | 13:41
Payment Events Status Timestamps