Loading...
HomeMy WebLinkAboutWQ0038128_Application (FTSE)_20200423Central Files: APS _ SWP 4/16/2020 Permit Number WQ0038128 Permit Tracking Slip Program Category Status Project Type Non -discharge In review Major modification Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions E Individual Primary Reviewer Permit Contact Affiliation dean.hunkele Coastal SWRule Permitted Flow 79,560 Facility Name Major/Minor Region Stateside Development Sewer Minor Wilmington Location Address County Onslow Facility Contact Affiliation Owner Owner Name Owner Type Old North State Water Company LLC Non -Government Owner Affiliation Michael J. Myers Dates/Events 4700 Homewood Ct Raleigh NC 27609 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue 1/7/2016 4/13/2020 PARKER & ASSOCIATES, INC J A C K S O N V I L L E, NORTH CAROLIN TO: Mr. Dean Hunkele NCDEQ-DWR 127 Cardinal Drive Extension Wilmington, NC 28405 - 3845 LETTER OF TRANSMITTAL DATE: April 7, 2020 GE-1V RE APR 1 3'2020 REF: Bennett Pl, Sec IV, Somerset P1 Sect IV and Roanoke Bay III at Stateside Sewer Improvements Fast Track Sewer Application WE ARE SENDING YOU: One (1) Original and One (1) Copy of the Fast Track Sewer Application; One (1) Sewer Narrative; One (1) Original and One (1) Copy of the Flow Tracking Form;One (1) Check No. 40133 in the amount of $480.00 for the application fee; and One (1) Portion of the USGS Map. DELIVERY VIA: Z Regular Mail ❑ Hand ❑ Federal Express ❑ UPS Overnight ❑ UPS Ground ❑ Other THESE ARE TRANSMITTED AS CHECKED BELOW: ❑x For Approval ❑X As Requested ❑ For Review and Comment ❑ For Your Use ❑ For Bids Due ❑ Other COMMENTS: The WWTPfor this project is now certified with additional,llow and can handle the remainder of this project ,& � AV')7 -1A- ec: A. Sydes Construction, Inc. (LOT Only) Anthon G. Moctezuma, Staff Engineer AGM/brs CF (P), LAM, TMS (if enclosures are not as noted, kindly notify us at once) secretary. c2.2020.Foms.stateside.LOT.Hunkele.BennettPl] V.FastTrackSewerapplication.4.7.2020 306 New Bridge Street I P.O. Box 976 I Jacksonville, NC 28541-0976 I (910) 455-2414 Firm License Number F-0108 I www.parkerjacksonville.com Division of Water Resources State of North Carolina Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Old North State Water Company. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Lee Bowman per 15A NCAC 02T .0106(b) Title: Designated Representative 4. Applicant's mailing address: 4700 Homewood Ct, Suite 108 City: Raleigh State: NC Zip: 27699 5. Applicant's contact information: Phone number: (252) 235-4900 Email Address: lbowman@�envirolinkinc.com II. PROJECT INFORMATION: 1. Project name: Bennett PI IV Somerset PI IV and Roanoke Bay III at Statesi 2. Application/Project status: ❑ Proposed (New Permit) ® Existing Permit/Projectl O If a modification, provide the existing permit number: W00038128 and issued date: 5/11 \1_'�tq -aol 1 If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Onslow 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.8645' Longitude:-77.4834' 5. Parcel ID (if applicable): 157155 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Jason A. Houston License Number: 34978 Firm: Parker & Associates. Inc. Mailing address: 306 New Bridge Street City: Jacksonville State: NC Zip: 28540 Phone number: (910) 455-2414 Email Address: office(&parkerjacksonville.com W. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Stateside WWTF Permit Number: W00035809 Owner Name: Old North State Water Company, LLC V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): W00038128 Downstream (Receiving) Sewer Size: 8 inch St stem Wide Collection System Permit Number(s) (if applicable l: WQCS_ Owner Name(s): Old North State Water Company. LLC FORM: FTA 04-16 Page I of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Dev_eloper's Operational_ Agreement (FORM: DEV i been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Honrc/PropeitN Owners' Association.. has an Operational Agreement i FO_RM:._HnAI been attached? [—]Yes []No ®N/A 4. Origin of wastewater: (check all that apply): ® Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial 0 % Commercial 0 % Industrial (See 15A NCA_C 02T .0.103(201) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 02T .o114(I)? ❑ Yes ® No ➢ If yes, provide a copv of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0I 14(f)) Daily Design Flow'" No. of Units Flow Dwelling Units ------ 360 gaVUnit 143 51,480 GPD ------- gal/ GPD _ gall GPD gal/ GPD gal/ GPD ----- gaV GPD Total _ 51,480 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 51,480 GPD (per 1_5A NCAC 02T .0114) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: _ ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material ➢ Section 11 & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing Imes to meet minimum slope requirement is not allowed and a violation of the MDC VHI. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mainsl: COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: 0Longitude: 3. Design flow of the pump station: _ millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): _ gallons per minute at _ feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305 I( t)t 11: ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(1)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305tI) & (g) ➢ 15A NCAC 02T.0305( f) contains minimum separations that shall be provided for sewer Setback systems: _ Sepa 1 ticri inches Sto;;� vets and other utilities sted tical 1 elow inrben !r Water mains (vertical -water over sewer including na benched trenches) g nchesRequired Water mains (horizontal I_ --- 10 feet Reclaimed water lines (vertical - reclaimed over sewers _ _ _ _ 18 inches Reclaimed water lines (horizontal - reclaimed over sewers 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal **Any other stream, lake, impoundment, or ground water lowering and surface drainage Anv building foundation , _ 5 feet _ ._ __� Any basement _ _ _ 10 fee[ Top slope of embankment or cuts of 2 feet or more vertical height 10 feet ➢ 15A NCAC 02T.0305(e) contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NCSurface Classifications webpaee ➢ If noncompliance with 02T.0305(f) or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ® Yes ❑ No ❑ N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A_NCAC _02B .0200? ® Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 211.9102 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 40.1_&. Buffer- Permitting Branch 5. Does project comply with 15A NCAC -02T.0lOS(c)(6) (additional permits/certifications)? ® Yes [:]No Per 15A NCACO2T.0105Ic)t6). directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection Ines that are deemed "high -priority?" Per 15A_NCAC ..02T,0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: 1. Dees the submitted system comply with 15A. NCAC 02T, the Uninium_I)eskun Critcria_for the Permitting of Puml' qta mns and Force Mains , latest vemoni, and the Gravih Sewer Minimum Design Criteria llatest version) as applicable? ❑ Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. .Approval of the request is renuired prior to submittal of the Fast Track Application and smmortine documents. 2. Professional Engineer's Certification: I Jason A. Houston, P.E. attest that this application for (Professional Engineer's name fmm Application Item Ill.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6E, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. , • r 1 I 1 i r r, . North Carolina Professional Engineer's seal, signature, and date: i ` �•. of O,y. v 4� SEAL pr; 34978 3. Applicant's Certification per 15A NCAC 02T .0106(b): I, Lee. Bowman, Designated Representative attest that this application for (Signature Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215,613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature:---,_-\�.._.----- -----. Dater FORM: FTA 04-16 Page 5 of 5 State of North Carolina Department of Environmental Quality Division of Water Resources Division of water Resources Flow Tracking for Sewer Extension Applications (FTSE 10-18) Entity Requesting Allocation: Old North State Water Company, LLC Project Name for which flow is beingrequested: Bennett Place IV, Somerse , ace an re quesRnnnnka Ray III at Siatacirtp More than one FTSE may he required for a single project if the owner of the WWTP is not responsible for aft pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: Stateside WWTF b. WWTP Facility Permit #: WQ0035809 All flows are in MGD C. WWTP facility's permitted flow 0.125 d. Estimated obligated flow not yet tributary to the WWTP 0.029 c. WWTP facility's actual avg. flow 0-016 f. Total flow for this specific request 0.052 g. Total actual and obligated flows to the facility 0.097 h. Percent of permitted flow used 77.6% H. Complete this section for each pump station you are responsible for along the route of this wastewater flow. proposed List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, PUMP Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow"* Current Tributary Flow Plus (Name or Permit Capacity, • (Firm /pf), Avg. Daily Daily Flow, Obligated Available Number) No. MOD MGD Flow, MGD MGD Flow Capacity*** Stateside Blvd. WQ 0038128 0.320 0.128 0,016 0.052 0.068 0.060 —— * The Firm Capacity (design flow) of any pump station is de —fined as the or pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daffy Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(e) of the Minimum Design Criteria. *** A Planting Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is <0. Downstream Facility Name (Sewer): Stateside Development Sewer Downstream Permit Number: WQ 0038128 Page 1 of 6 FTSE 10-18 III. Certification Statement: I Lee Bowman certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. e� AR c Signing O rcial Signature Date Lee Bowman, Designated Representative Title of Signing Official Page 2 of 6 FTSE 10-18 BENNETT AND SOMERSET PLACE, SECTION IV AND ROANOKE BAY, SECTION III AT STATESIDE Sewer Narrative April 2020 This project is a proposed 163 Lot residential subdivision. The purpose of this modification is to permit the remaining 143 lots of this project. Previously, under permit WQ0038128, this project was permitted with only 20 lots. The previous permit also included 8,700 feet of 8-inch gravity sewer, and a 180 GPM pump station with 2,053 feet of 6-inch force main. The WWTP for this project is now certified with an additional 75,000 GPD, and can treat the remainder of this project. 85 of these lots drain towards the existing pump station, named "Stateside Blvd" and the remaining 78 drain towards the proposed pump station "Bennet PI IV". Total percent of flow used for the W WTP, including the proposed 143 lots, would now be at 77.6%. secretary. c2.2020. Forms. Stateside. BennettPl,SomerselPI W.Hunkele.Sewemarrative.3.27.2020 U.S. DEPA' -MENT OF THE INTERIOR PA USGS 1,24 U.S. AOLOGICAL SURVEY -scienceforad Mo L 0 )Vod4 17030' 2 U� (r; /`hp Jo.. 72DDO. 273 '741: '75 2 6 'PAC 44 ranch - .50 IV 0-N W JG b 'o da "15 f M60 A A., V it 11z 49 659 • Mf 58 BP�pg_ r K f it, '57 DIR fe j