HomeMy WebLinkAboutWQ0010670_Application_19950227I ve
Statb of North Carolina
Department of Environment,
Health and Natural Resources
Division of Environmental Management
James B. Hunt, Jr., Governor
Jonathan B. Howes, Secretary
A. Preston Howard, Jr., P.E., Director
A "W
T4 0
oft
C2EHNR
aECEIVEn
February 27, 1995 MAD 2 1995
MR STEVEN BIGGS
TOWN OF ABERDEEN
PO BOX 785
ABERDEEN, NORTH CAROLINA 28315
Dear MR BIGGS:
ENV. MANAGEMENT
FAYETTEVILLE REG. OFFICE
R
Subject: Application No. WQ0010670
Industrial Park Imp
Sewers -Public
Moore County
The Division's Permits and Engineering Unit acknowledges receipt of your permit application and
supporting materials on February 27, 1995. This application has been assigned the number listed
above. PLEASE REFER TO THE ABOVE WATER QUALITY NUMBER WHEN MAKING
INQUIRES ON THIS PROJECT.
rq
Your project has been assigned to Buzz Crosby for a detailed engineering review. Should. there be any
questions concerning your project, the reviewer will contact you with an additional information letter.
Be aware that the Division's regional office, copied below, must provide recommendations from the
Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the
Division.
If you have any questions, please contact Buzz Crosby at (919) 733-5083. �P/�'� 527
cc: Fayetteville Regional Office
Hobbs Upchurch & Associates
Sincerely,
/1a
yrol n McCaskill
!'
Supervisor, State Engineering Review Group
Pollution Prevention Pays
P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015
An Equal Opportunity Affirmative Action Employer
MEMO TO: State Review Group
FROM: Ricky Revels R� R.t.�
Environmental Technician IV
SUBJECT: Procedure Four (4)
WQ0010670
Industrial Park Imp.
Sewer Extension - Public
Town of Aberdeen
Moore County
Division of Environmental
Management
Fayetteville Regional
Office
30695
Date
State Review Group Review
Engineer Buzz Crosby
Regional Office
Contact Ricky Revels
1) Name of wastewater treatment plant to receive the wastewater:
Moore County Regional Wastewater Treatment Plant
2) WWTP design capacity 6_7 MGD
3) NPDES Permit No.: NCO037508 Expiration Date: 4 30 97
4) Compliance Information:
Present treatment plant performance
for previous 12 months - beginning 2194
(See attached self -monitoring data)
5) Quantity and type of wastewater from proposed sewers:
20,000 GPD
domestic 100% industrial other
6) Volume from previously approved projects not yet tributary to
WWTP 1,218,497 GPD
7) Regional Recommendations: Approval X Denial
RR/rr
Enclosure
I
State of North Carolina
Department of Environment, Health, and Natural Resources
Division of Environmental Management
Non -Discharge Permit Application
(THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL)
GRAVITY SEWER EXTENSION
I. GENERAL INFORMATION:
1. Applicant (corporation, individual, or other): Town of Aberdeen
2. Print Owners or Signing Official's Name and Title (the person who is legally
responsible for the facility and its compliance): Steven Biggs, Town Manager
3. Mailing Address: P.O. Bog 785
City: Aberdeen State: N.C. Zip: 28315
Telephone No.: 9( 10 ) 944-1115
4. Project Name (subdivision, facility, or establishment name - should be consistent with
project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.):
Utility Improvements to serve vroposed Industrial Park
5. Application Date: February 17, 1995 6. Fee Submitted: $ 400.00
7. County where project is located:
II. PERMIT INFORMATION:
Moore
1. Permit No. (will be completed by DEM):
2. Specify whether project is: % new; renewal*; modification.
*If renewal, complete only sections I through III and applicant signature
(on pg.5). Submit only pgs. 1, 2, 5 (original and 3 copies of each). Engineer
signature not required for renewal.
3. If this application is being submitted as a result of a renewal or modification to an
existing permit, list the existing permit number N/A and issue date
4. Specify whether the applicant is X public or private.
FORM: GSEA 4/91 Page 1 of 6
GRAVITY SEWER EXTENSION
PAGE 2 (4/91)
III. INFORMATION ON WASTEWATER:
1. Nature of Wastewater. 93 % Domestic; % Commercial;
7 % Industrial; % Other waste (specify):
2. Please provide a one or two word description specifying the origin of the wastewater,
such as school, subdivision, hospital, commercial, industrial, apartments, etc.:
Commercial & Light Industrial with one wicrobrewery at 1400 gpd
3. Indicate any parameter (and its concentration) that will be greater than normal domestic
levels: 1400 gpd with 1900 mg/L TSS & 6000 me/L BOD
4. If wastewater is not domestic in nature, what level of pretreatment has been provided to
ensure protection of the receiving wastewater treatment facility?
All wastewater will be domestic in nature except for brewery. No pre-
treatment is expected because of .minute volume of.flow
5. Volume of wastewater generated by this project: 20,000 gallons per day
6. Explanation of how wastewater volume was determined: 10 lots x 2000 gal/day
= 20,000 gal/day
IV. DESIGN INFORMATION:
1. Brief project description: 1779 LF of 8" PVC SDR35 and 7 manholes
Moore Water Pollution
2. Name of wastewater treatment facility receiving wastewater: County Facility
a. Facility permit no.: NP DES # NC0037508
b. Engineer should provide statement of his evaluation of downstream sewers to
accept the wastewater: Down stream sewers are adequate to accept
the wastewater generated bV this proiect
2of6
'RAVITY SEWER EXTENSION
i'AGE 3 (4/91)
3.
Dia.
(In.) (Lin
8"
NOTE: 'Yhe
For
4.
spa. .
i= U.
consk
B-
5.
6. This L .
7. Doc3 ,.
8.
It� vc:
9 ( )'
10. Idew:
pe material. Indicate here whether C
N
Minimum Max. Minimum
Velocity (fps) Vel.(fps) Cover (in)
4.118 14.361 36"
p s_
:aches.
�s greater than 20 %. The anchor
.rater.
c 1 y recommended that measures be
--. anholes from erosion. For velocities
r be specified.
ccur in any sewer line segment, what
:;e and manholes?
171.68 linear feet.
r)o. 1 and manhole no. 2
Lhis length? X Yes No.
loads? Yes X No.
sewers to withstand the loads?
eparations exceed: 2.5 feet.
have drop connections: N/A
GRAVITY SEWER EXTENSIQN
PAGE 4 (4/91)
11. Maximum allowable infiltration/exfiltration test rate:
Note: Must not exceed 200 GPD/ pipe dia. ind mile. 100 GPD/ pipe dia. in./ mile.
12. Minimum separation distances as shown on the plans or addressed in the specifications:
a) 100 ft. horizontal separation from wells or other water supplies? g Yes _ No
b) 12 in. vertical separation from storm sewer or ferrous pipe
sanitary sewer specified? % Yes —No
c) 10 ft horizontal separation from water mains or 18 in. vertical
separation (water over sewer) or ferrous pipe specified? % Yes —No
13. Are manholes subject to flooding? _Yes g No
14. If yes, are manhole rim elevations 1 foot above 100-year flood level, _ Yes _ No
(100 year flood elevation should be indicated on plans)
15. Or are manholes watertight and vented 1 foot above the 100-year
flood elevation ( should be shown on plans): _Yes —No
16. Identify (by manhole number) those manholes that are vented: N/A
17. Does this project involve any stream crossings? _ yes g no. If yes, what precautions
or special features have been utilized to ensure protection of the sewer line and not
restrict stream flow? Identify the sheet of the plans and station number where stream
crossings are located:
THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE
DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF
THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL
Required Items
a. One original and three copies of the completed and appropriately executed application form.
b. Three sets of detailed plans and specifications signed and sealed by a North Carolina
Professional Engineer. The plans must include a general location map, a plan view of the
sewer extension, a profile of the sewer extension, and must show the proximity of the
sewer extension to other utilities and natural features. Specifications may be omitted for
delegated authorities. Each sheet of the plans and the fast page of the specifications must be
signed and sealed. Three copies of the existing permit if a renewal or modification.
C. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5).
d. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting
the wastewater flow from this project is different from the applicant of the project, then a
letter must be provided from the owner/authority of the WWTF specifying the volume of
flow that will be accepted. The letter should be a recent letter and should refer to the project
by the same name as that identified on the application and the plans/specifications.
e. An Operational Agreement (original and two copies) must be submitted if the sewer
extension will be serving single family residences, condominiums, mobile homes, or town
houses and if the subject sewer extension is owned by the individual residents, a
homeowners association, or a developer.
4of6
' GRAVITY SEWER EXTENSION
PAGE 5 (4/91)
Name and Complete Address of Engineering Firm: Hobbs, Upchurch & Associates, P.A.
P.O. Bog 1737, 290 S.W. Broad Street
City: Southern Pines
Telephone No.
910-692-5616
State:
North Carolina
Zip
28388
Professional Engineer's Certification:
1, David T. Upchurch , attest that this application for utility Improvementp
to serve proposed Industrial Park has been reviewed by me and is accurate
and complete to the best of my knowledge. I further attest that to the best of my knowledge the
proposed design has been prepared in accordance with the applicable regulations. Although certain
portions of this submittal package may have been developed by other professionals, inclusion of
these materials under my signature and seal signifies that I have reviewed this material and have
judged it to be consistent with the proposed design.
North Carolina Professional Engineer's Registration No.
Print Name of Engineer David T. Upchurch
9570
Seal and Signature (specify date): Z'�.•'o �`• '
Applicant's Certification:• T, UPGC��'`2
IUH1'
I, Steven Biggs ,attest that this application for Utility Improvements
to serve proposed Industrial Park
has been reviewed by me and is accurate and complete to the best of my knowledge. I understand
that if all required parts of this application are not completed and that if all required supporting
information and attachme is are not included, this application package will be returned as
incomplete.
Signature - 1�� Date
THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING
INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS:
NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT
WATER QUALITY SECTION
PERMITS AND ENGINEERING UNIT
POST OFFICE BOX 29535
512 NORTH SALISBURY STREET
RALEIGH, NORTH CAROLINA 27626-0535
TELEPHONE NUMBER: 919/733-5083
5of6
GRAVITY SEWER EXTENSIQN
PAGE 6 (4/91) '
PERMIT APPLICATION PROCESSING FEES
(effective October 1,1990)
CATEGORY
> 1,000,000 GPD
Industrial
Domestic/Cooling Water
10,001 - 1,000,000 GPD
Industrial
Domestic/Cooling Water
1,001 - 10,000 GPD
NEW APPLICATIONS/
MODIFICATIONS
Industrial C,Y•' $4W
Domestic/Coolin&Witert_�, E $400
< or = 1,000 GPD and
Single Family Dwe'$240
Sludge < or = 300 Acres $400
RENEWALS WITHOUT
MODIFICATIONS
$300
$300
$250
$250
$200
$200
$120
$250
Sludge > 300 Acres
$400
$250
Sewer Extensions
(nondelegated)
$400
0
Sewer Extensions
(delegated)
$200
0
Closed -Loop Recycle
or Evaporative
$400
$200
NOTE: The Fees for Soil Remediation Projects are the same as for Sludges.
Under the Sewer Extension Fee, "delegated to municipalities" applies
only to those governmental jurisdictions that have specific delegation
review authority, as granted by the Division of _Environmental
Management.
6of6
0 01 E ` VVatET & =S-ECVET CZ4uffiaziEy
Water Pollution Control System
P. O. Box 813
Pinebluff, North Carolina 28373
OFFICE OF SYSTEM SUPERINTENDENT O.W.A.+
04
198
so o'
February 21, 1995 "4'COUVA41
Hs. Carolyn McCaskill, Supervisor
State Engineering Review Group
N.C. Dept. of Environmental Health & Natural Resources
Division of Environmental Management
P.O. Box 27687
Raleigh,N.C. 27611
Re: Proposed Industrial Park Utility Improvements
HUA NO: #56-138-0107
Dear Hs. I•lcCaskill:
TELEPHONE: 910-281-3146
FAX: 910-281-2047
F
RECERI)
FEB 29, 1995
ENV. MANAGEMENT
FAYETTEVILLE REG. OFFICE
The Moore County plater Pollution Control Facilities hereby agrees
to conditionally accept up to 20,000 gallons per day of wastewater
from the referenced project in accordance with request of February
21, 1995 by Hobbs,Upchurch & Associates, P.A., of Southern Pines,
N._.
Upon completion of the referenced project, the applicant's: engineer
is to provide this office with the following items:
1. Infiltration in gallons per day.
2. Certification of completion as defined by N.C.
Statutory Requirements #143-215.1; Section 2-H.0220.
3. Complete set of As -Built drawings as approved by Engineer.
4. All shop drawings/ 0 & 11 Hanuals, Diagrams, Illustrations,
schedule & brochure which illustrate how specific portions
were fabricated and installed.
After Hoore County has received a copy of the certification of
completion, our office will provide a final acceptance statement.
hncerely,
y A(. Frick
System Superintendent
emb
pc: Air. Jim Tarnow, F.E. , lloore plater and Sewer Authority
Hr. Hitch Coleman, Exec. Director, 1locre [later and Sewer Authority
1-Ir. Steve Biggs, Town ilanager, Tom of Aberdeen
Aires Lee Humphrey P.E., Hobbs, Upchurch & Assoc, P.A.
�1 Kerr T. Stevens, Dept. of EHNR, Fayetteville
11r. 1.1. David IlcNeill, Jr. , County Hanager
,__1fl00TE ( VVaEET f ,=S-EWF-T CZ-::;4LA0ziEy
Water Pollution Control System
P. O. Box 813
Pinebluff, North Carolina 28373
OFFICE OF SYSTEM SUPERINTENDENT ro•W �•t�
104 198
so
o �•
November 7, 1994 'tCouNI
TELEPHONE: 910-281-3146
FAX: 910-281-2047
;OV 1994
IN V.
tis.s�
Ms. Carolyn McCaskill, Supervisor
State Engineering Review Group
N.C. Dept. of Environmental Health & Natural Resources
Division of Environmental Management
P.O. Box 27687
Raleigh,N.C. 27611
Re: Town of Aberdeen- Sanitary Sewer Improvements
Sandhill Industrial Park
HUA No. AB9406
Dear Ms. McCaskill:
The Moore County Water Pollution Control Facilities hereby agrees
to conditionally accept up to 28,500 gallons per day of wastewater
from the referenced project in accordance with request of Nov.2,
1994 by Hobbs,Upchurch & Associates, P.A., of Southern Pines, N.C.
Upon completion of the referenced project, the applicant's engineer
is to provide this office with the following items:
1. Infiltration in gallons per day.
2. Certification of completion as defined by N.C.
Statutory Requirements #143-215.1; Section 2-H.0220.
3. Complete set of As -Built drawings as approved by Engineer.
4. All shop drawings/ 0 & M Manuals, Diagrams, Illustrations,
schedule & brochure which illustrate how specific portions
were fabricated and installed.
After Moore County has received a copy of the certification of completion,
our office will provide a final acceptance statement.
incerely,
ary A. Frick
System Superintendent
emb
pc: Mr. Jim Tarnow, P.E., Moore Water and Sewer Authority
Mr. Mitch Coleman, Exec. Director, Moore Water and Sewer Authority
Mr. Steve Biggs, Town Manager, Town of Aberdeen
Mr. Chuck Cowherd, Hobbs, Upchurch & Assoc, P.A.
,-Wr-. Kerr T. Stevens, Dept. of EHNR, Fayetteville
Mr. W. David McNeill, Jr., County Manager