HomeMy WebLinkAboutWQ0010670_Application_19950227I ve Statb of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director A "W T4 0 oft C2EHNR aECEIVEn February 27, 1995 MAD 2 1995 MR STEVEN BIGGS TOWN OF ABERDEEN PO BOX 785 ABERDEEN, NORTH CAROLINA 28315 Dear MR BIGGS: ENV. MANAGEMENT FAYETTEVILLE REG. OFFICE R Subject: Application No. WQ0010670 Industrial Park Imp Sewers -Public Moore County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on February 27, 1995. This application has been assigned the number listed above. PLEASE REFER TO THE ABOVE WATER QUALITY NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. rq Your project has been assigned to Buzz Crosby for a detailed engineering review. Should. there be any questions concerning your project, the reviewer will contact you with an additional information letter. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Buzz Crosby at (919) 733-5083. �P/�'� 527 cc: Fayetteville Regional Office Hobbs Upchurch & Associates Sincerely, /1a yrol n McCaskill !' Supervisor, State Engineering Review Group Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer MEMO TO: State Review Group FROM: Ricky Revels R� R.t.� Environmental Technician IV SUBJECT: Procedure Four (4) WQ0010670 Industrial Park Imp. Sewer Extension - Public Town of Aberdeen Moore County Division of Environmental Management Fayetteville Regional Office 30695 Date State Review Group Review Engineer Buzz Crosby Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: Moore County Regional Wastewater Treatment Plant 2) WWTP design capacity 6_7 MGD 3) NPDES Permit No.: NCO037508 Expiration Date: 4 30 97 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 2194 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 20,000 GPD domestic 100% industrial other 6) Volume from previously approved projects not yet tributary to WWTP 1,218,497 GPD 7) Regional Recommendations: Approval X Denial RR/rr Enclosure I State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER EXTENSION I. GENERAL INFORMATION: 1. Applicant (corporation, individual, or other): Town of Aberdeen 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): Steven Biggs, Town Manager 3. Mailing Address: P.O. Bog 785 City: Aberdeen State: N.C. Zip: 28315 Telephone No.: 9( 10 ) 944-1115 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): Utility Improvements to serve vroposed Industrial Park 5. Application Date: February 17, 1995 6. Fee Submitted: $ 400.00 7. County where project is located: II. PERMIT INFORMATION: Moore 1. Permit No. (will be completed by DEM): 2. Specify whether project is: % new; renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.5). Submit only pgs. 1, 2, 5 (original and 3 copies of each). Engineer signature not required for renewal. 3. If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit number N/A and issue date 4. Specify whether the applicant is X public or private. FORM: GSEA 4/91 Page 1 of 6 GRAVITY SEWER EXTENSION PAGE 2 (4/91) III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater. 93 % Domestic; % Commercial; 7 % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: Commercial & Light Industrial with one wicrobrewery at 1400 gpd 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: 1400 gpd with 1900 mg/L TSS & 6000 me/L BOD 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? All wastewater will be domestic in nature except for brewery. No pre- treatment is expected because of .minute volume of.flow 5. Volume of wastewater generated by this project: 20,000 gallons per day 6. Explanation of how wastewater volume was determined: 10 lots x 2000 gal/day = 20,000 gal/day IV. DESIGN INFORMATION: 1. Brief project description: 1779 LF of 8" PVC SDR35 and 7 manholes Moore Water Pollution 2. Name of wastewater treatment facility receiving wastewater: County Facility a. Facility permit no.: NP DES # NC0037508 b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: Down stream sewers are adequate to accept the wastewater generated bV this proiect 2of6 'RAVITY SEWER EXTENSION i'AGE 3 (4/91) 3. Dia. (In.) (Lin 8" NOTE: 'Yhe For 4. spa. . i= U. consk B- 5. 6. This L . 7. Doc3 ,. 8. It� vc: 9 ( )' 10. Idew: pe material. Indicate here whether C N Minimum Max. Minimum Velocity (fps) Vel.(fps) Cover (in) 4.118 14.361 36" p s_ :aches. �s greater than 20 %. The anchor .rater. c 1 y recommended that measures be --. anholes from erosion. For velocities r be specified. ccur in any sewer line segment, what :;e and manholes? 171.68 linear feet. r)o. 1 and manhole no. 2 Lhis length? X Yes No. loads? Yes X No. sewers to withstand the loads? eparations exceed: 2.5 feet. have drop connections: N/A GRAVITY SEWER EXTENSIQN PAGE 4 (4/91) 11. Maximum allowable infiltration/exfiltration test rate: Note: Must not exceed 200 GPD/ pipe dia. ind mile. 100 GPD/ pipe dia. in./ mile. 12. Minimum separation distances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? g Yes _ No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? % Yes —No c) 10 ft horizontal separation from water mains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? % Yes —No 13. Are manholes subject to flooding? _Yes g No 14. If yes, are manhole rim elevations 1 foot above 100-year flood level, _ Yes _ No (100 year flood elevation should be indicated on plans) 15. Or are manholes watertight and vented 1 foot above the 100-year flood elevation ( should be shown on plans): _Yes —No 16. Identify (by manhole number) those manholes that are vented: N/A 17. Does this project involve any stream crossings? _ yes g no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and three copies of the completed and appropriately executed application form. b. Three sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the fast page of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or modification. C. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). d. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. e. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 4of6 ' GRAVITY SEWER EXTENSION PAGE 5 (4/91) Name and Complete Address of Engineering Firm: Hobbs, Upchurch & Associates, P.A. P.O. Bog 1737, 290 S.W. Broad Street City: Southern Pines Telephone No. 910-692-5616 State: North Carolina Zip 28388 Professional Engineer's Certification: 1, David T. Upchurch , attest that this application for utility Improvementp to serve proposed Industrial Park has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Registration No. Print Name of Engineer David T. Upchurch 9570 Seal and Signature (specify date): Z'�.•'o �`• ' Applicant's Certification:• T, UPGC��'`2 IUH1' I, Steven Biggs ,attest that this application for Utility Improvements to serve proposed Industrial Park has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachme is are not included, this application package will be returned as incomplete. Signature - 1�� Date THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: 919/733-5083 5of6 GRAVITY SEWER EXTENSIQN PAGE 6 (4/91) ' PERMIT APPLICATION PROCESSING FEES (effective October 1,1990) CATEGORY > 1,000,000 GPD Industrial Domestic/Cooling Water 10,001 - 1,000,000 GPD Industrial Domestic/Cooling Water 1,001 - 10,000 GPD NEW APPLICATIONS/ MODIFICATIONS Industrial C,Y•' $4W Domestic/Coolin&Witert_�, E $400 < or = 1,000 GPD and Single Family Dwe'$240 Sludge < or = 300 Acres $400 RENEWALS WITHOUT MODIFICATIONS $300 $300 $250 $250 $200 $200 $120 $250 Sludge > 300 Acres $400 $250 Sewer Extensions (nondelegated) $400 0 Sewer Extensions (delegated) $200 0 Closed -Loop Recycle or Evaporative $400 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer Extension Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Division of _Environmental Management. 6of6 0 01 E ` VVatET & =S-ECVET CZ4uffiaziEy Water Pollution Control System P. O. Box 813 Pinebluff, North Carolina 28373 OFFICE OF SYSTEM SUPERINTENDENT O.W.A.+ 04 198 so o' February 21, 1995 "4'COUVA41 Hs. Carolyn McCaskill, Supervisor State Engineering Review Group N.C. Dept. of Environmental Health & Natural Resources Division of Environmental Management P.O. Box 27687 Raleigh,N.C. 27611 Re: Proposed Industrial Park Utility Improvements HUA NO: #56-138-0107 Dear Hs. I•lcCaskill: TELEPHONE: 910-281-3146 FAX: 910-281-2047 F­ RECERI) FEB 29, 1995 ENV. MANAGEMENT FAYETTEVILLE REG. OFFICE The Moore County plater Pollution Control Facilities hereby agrees to conditionally accept up to 20,000 gallons per day of wastewater from the referenced project in accordance with request of February 21, 1995 by Hobbs,Upchurch & Associates, P.A., of Southern Pines, N._. Upon completion of the referenced project, the applicant's: engineer is to provide this office with the following items: 1. Infiltration in gallons per day. 2. Certification of completion as defined by N.C. Statutory Requirements #143-215.1; Section 2-H.0220. 3. Complete set of As -Built drawings as approved by Engineer. 4. All shop drawings/ 0 & 11 Hanuals, Diagrams, Illustrations, schedule & brochure which illustrate how specific portions were fabricated and installed. After Hoore County has received a copy of the certification of completion, our office will provide a final acceptance statement. hncerely, y A(. Frick System Superintendent emb pc: Air. Jim Tarnow, F.E. , lloore plater and Sewer Authority Hr. Hitch Coleman, Exec. Director, 1locre [later and Sewer Authority 1-Ir. Steve Biggs, Town ilanager, Tom of Aberdeen Aires Lee Humphrey P.E., Hobbs, Upchurch & Assoc, P.A. �1 Kerr T. Stevens, Dept. of EHNR, Fayetteville 11r. 1.1. David IlcNeill, Jr. , County Hanager ,__1fl00TE ( VVaEET f ,=S-EWF-T CZ-::;4LA0ziEy Water Pollution Control System P. O. Box 813 Pinebluff, North Carolina 28373 OFFICE OF SYSTEM SUPERINTENDENT ro•W �•t� 104 198 so o �• November 7, 1994 'tCouNI TELEPHONE: 910-281-3146 FAX: 910-281-2047 ;OV 1994 IN V. tis.s� Ms. Carolyn McCaskill, Supervisor State Engineering Review Group N.C. Dept. of Environmental Health & Natural Resources Division of Environmental Management P.O. Box 27687 Raleigh,N.C. 27611 Re: Town of Aberdeen- Sanitary Sewer Improvements Sandhill Industrial Park HUA No. AB9406 Dear Ms. McCaskill: The Moore County Water Pollution Control Facilities hereby agrees to conditionally accept up to 28,500 gallons per day of wastewater from the referenced project in accordance with request of Nov.2, 1994 by Hobbs,Upchurch & Associates, P.A., of Southern Pines, N.C. Upon completion of the referenced project, the applicant's engineer is to provide this office with the following items: 1. Infiltration in gallons per day. 2. Certification of completion as defined by N.C. Statutory Requirements #143-215.1; Section 2-H.0220. 3. Complete set of As -Built drawings as approved by Engineer. 4. All shop drawings/ 0 & M Manuals, Diagrams, Illustrations, schedule & brochure which illustrate how specific portions were fabricated and installed. After Moore County has received a copy of the certification of completion, our office will provide a final acceptance statement. incerely, ary A. Frick System Superintendent emb pc: Mr. Jim Tarnow, P.E., Moore Water and Sewer Authority Mr. Mitch Coleman, Exec. Director, Moore Water and Sewer Authority Mr. Steve Biggs, Town Manager, Town of Aberdeen Mr. Chuck Cowherd, Hobbs, Upchurch & Assoc, P.A. ,-Wr-. Kerr T. Stevens, Dept. of EHNR, Fayetteville Mr. W. David McNeill, Jr., County Manager