Loading...
HomeMy WebLinkAboutNC0025461_Permit (Application Amendment)_20190724Water Quality Lab & Operations, Inc. P.O. Box 1167/ 1522 Tynecastle Highway Banner Elk, NC 28604 Ph. 828-898-6277 Fax 828-898-6255 July 24, 2019 Ms. Emily Phillips, Environmental Specialist NCDEQ/DWR/Compliance and Expedited Permitting Unit 1617 Mail Service Center Raleigh, NC 27699-1617 Via E-mail to sarah.phillips@ncdenr.gov Re: Bakersville WWTP NPDES NCO025461 Dear Ms. Phillips: 2I. ' I� AUG 19 2019 DO Water Quality Regional Operatlons Asheville Regional 0&0 Please find enclosed an application for the permit renewal for the Town of Bakersville. All items on the checklist are included with the permit renewal. There have been no significant changes to the facility since the previous permit cycle. If we can be of further assistance, please do not hesitate to contact us. Sincerely, 6addBrewer Signatory Authority NPDES APPLICATION FOR PERMIT RENEWAL - FORM A For Publicly Owned Treatment Works (POTW) or other treatment systems treating domestic wastes < 0.1 MGD with no pretreatment program. Mail the complete application to: NC DEQ / DWR / NPDES 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit 000025461 If you are completing this form in computer use the TAB key or the up — down arrows to move from one field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type. 1. Contact Information: Owner Name Town of Bakersville, c/o Charles Vines, Mayor Facility Name Bakersville WWTP Mailing Address P.O. Box 53 City Bakersville State / Zip Code NC Telephone Number (828)688-2113 Fax Number (828)688-3666 e-mail Address cvines@bakersvillenc.com, cvines@mitchell.main.nc.us 2. Location of facility producing discharge: Check here if same address as above ❑ Street Address or State Road 303 Bakers Lane City Bakersville State / Zip Code NC 28705 County Mitchell 3. Operator Information: Name of the firm, public organization or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Water Quality Lab and Operations, Inc. Mailing Address City State / Zip Code Telephone Number Fax Number P.O. Box 1167 Banner Elk NC 28604 (828)898-6277 (828)898-6255 4. Population served: 725 5. Do you receive industrial waste? 1 of 3 Form -A b/2017 NPDES APPLICATION FOR PERMIT RENEWAL - FORM A For Publicly Owned Treatment Works (POTW) or other treatment systems treating domestic wastes < 0.1 MOD with no pretreatment program. 0 No ❑ Yes (if you have an approved pre-treatment program, must complete Form 2A) 6. Type of collection system 0 Separate (sanitary sewer only) 7. Out fall Information: ❑ Combined (storm sewer and Number of separate discharge points 1 Outfall Identification number(s) 001 Is the outfall equipped with a diffuser? ❑ Yes ® No wale, Regon�,0 at!', Reg)onal U fire x ee -, S. Name of receiving stream(s) (Provide a map showing the exact location of each outfall): Cane Creek, French Broad River Basin 9. Frequency of Discharge: Continuous 07 Intermittent If intermittent: Days per week discharge occurs: Duration: 'ID m, n fes 10. Describe the treatment system List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and phosphorus. /f the space provided is not sufficient, attach the description of the treatment systern in a separate sheet of paper. Submersible influent pump station with dual 350-GPM influent pumps • Manual bar screen • Flow Splitter Box • Flow equalization basin • Dual (2) each 100,000 gallon Intermittent Cycle Extended Aeration System (ICEAS)/Sequencing Batch Reactor hybrid process/ dual (2) each 25-HP blowers (dual (2) each 100-HP motors) • Three (3) each 0.025 MOD extended aeration package plants converted to aerobic sludge digestion, thickening, and storage • Ultraviolet (UV) disinfection [Degremont Technologies Infilco equipment, 8 banks, each with 4 bulbs] • 2870 gallon post aeration chamber • Effluent weir/Isco ultrasonic flow measurement • Back-up power generator (Kohler 60-kW, diesel) 11. Flow Information: Treatment Plant Design flow 0.200 MGD Annual Average daily now 0.0947 MOD (for the previous 3 years) Maximum daily flow 0.9 MMGD (for the previous 3 years) 12. Is this facility located on Indian country? ❑ Yes ® No 2 of 3 Form -A w207 NPDES APPLICATION FOR PERMIT RENEWAL - FORM A For Publicly Owned Treatment Works (POTW) or other treatment systems treating domestic wastes < 0.1 MGD with no pretreatment program. 13. Effluent Data Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other parameters 24-hour composite sampling shall be used. Effluent testing data must be based on at least three samples and must be no more than four and one half years old. Parameter Daily Maximum Monthly Average Units of Measurement Number of Samples Biochemical Oxygen Demand (BODs) 17.4 10.1 mg/L 140 Fecal Coliform 400 73.48 cuf/ 100mL 140 Total Suspended Solids 32 12.5 mg/L 140 Temperature (Summer) 28 226.4 ° C 83 Temperature (Winter) 18 16.6 °C 57 pH 7.7 7.1 s/u 140 14. List all permits, construction approvals and/or applications: Type Permit Number Hazardous Waste (RCRA) UIC (SDWA) NPDES NCO025461 PSD (CAA) Non -attainment program (CAA) 15. APPLICANT CERTIFICATION Type NESHAPS (CAA) Ocean Dumping (MPRSA) Dredge or fill (Section 404 or CWA) Special Order of Consent (SOC) Other Permit Number I certify that I am familiar with the information contained in the application and that to the best of rov knowledge and belief such information is true, complete, and accurate. J 12,rewur Stc mvo"A e#,qA .ES l_ , VI"i Es M A�yoP_ name of Person 4E sigl3piVre of Applicant Date No Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar offense.) 3 of 3 form -A 6017 Water Quality Lab & Operations, Inc. P.O. Box 1167/ 1522 Tynecastle Highway Banner Elk, NC 28604 Ph. 828-898-6277 Fax 828-898-6255 TOWN OF BAKERSVILLE WWTP SLUDGE MANAGEMENT Sludge is managed via a commercial hauler, Triple T located on 1372 NC Hwy 194 N, Boone, NC 28607. Ally 19 201 water Qu 9 ality Re Asheville Regional pace ticns Town of Bakersville Incorporated 1870 "Gata,cav to Roan Mountain" Mayor: Charles E. Vines July 30, 2019 Wastewater Branch Water Quality Permitting Section Division of Water Resources 1617 Mail Service Center Raleigh. NC 27699-1617 Subject: Delegation of Signature Authority Town of Bakersville NPDES Number NCO02WI To Whom It May Concern: Town Council: Charles Nash Jordon Baker Beau Thomas By notice of this letter, I hereby delegate signatory authority the following individual for all permit applications, discharge monitoring reports, and other information relating to the operations at the subject facility as required by all applicable federal, state, and local environmental agencies specifically with the requirements for signatory authority as specified in ISA NCAC 2B.0506. Jadd Brewer Operations Manager P.O. Box 1167 1522 Tynecastle Hwy Banner Elk, NC 28604 jaddbrewer@rocketmail.com 828-898-6277 828-260-2027 26 Mitchell Ave 0 PO Box 53 Bakersville NC 28705-0053 0 www.bakersvillene.com Phone•828fi88-2113 0 Pat 82"88.2745 0 E-mail Address inlia bakersvillenc.wnn If you have any questions regarding this letter, please feel free to contact me at 828.688- 2113. Sincerely, (1-�'�a&f �-.✓' Charles Knes Mayor Town of Bakersville P.O. Box 53, Bakersville, NC 28705 evines@bakersvillene.com, cvines(:W�mitchell.main.nc.us 828-688-2113 cc: Asheville Regional Office, Water Quality Permitting Section