HomeMy WebLinkAboutNC0025461_Permit (Application Amendment)_20190724Water Quality Lab & Operations, Inc.
P.O. Box 1167/ 1522 Tynecastle Highway
Banner Elk, NC 28604
Ph. 828-898-6277 Fax 828-898-6255
July 24, 2019
Ms. Emily Phillips, Environmental Specialist
NCDEQ/DWR/Compliance and Expedited Permitting Unit
1617 Mail Service Center
Raleigh, NC 27699-1617
Via E-mail to sarah.phillips@ncdenr.gov
Re: Bakersville WWTP NPDES NCO025461
Dear Ms. Phillips:
2I.
' I�
AUG 19 2019 DO
Water Quality Regional Operatlons
Asheville Regional 0&0
Please find enclosed an application for the permit renewal for the Town of Bakersville.
All items on the checklist are included with the permit renewal. There have been no
significant changes to the facility since the previous permit cycle.
If we can be of further assistance, please do not hesitate to contact us.
Sincerely,
6addBrewer
Signatory Authority
NPDES APPLICATION FOR PERMIT RENEWAL - FORM A
For Publicly Owned Treatment Works (POTW) or other treatment systems treating
domestic wastes < 0.1 MGD with no pretreatment program.
Mail the complete application to:
NC DEQ / DWR / NPDES
1617 Mail Service Center, Raleigh, NC 27699-1617
NPDES Permit 000025461
If you are completing this form in computer use the TAB key or the up — down arrows to move from one
field to the next. To check the boxes, click your mouse on top of the box. Otherwise, please print or type.
1. Contact Information:
Owner Name
Town of Bakersville, c/o Charles Vines, Mayor
Facility Name
Bakersville WWTP
Mailing Address
P.O. Box 53
City
Bakersville
State / Zip Code
NC
Telephone Number
(828)688-2113
Fax Number
(828)688-3666
e-mail Address
cvines@bakersvillenc.com, cvines@mitchell.main.nc.us
2. Location of facility producing discharge:
Check here if same address as above ❑
Street Address or State Road 303 Bakers Lane
City Bakersville
State / Zip Code NC 28705
County Mitchell
3. Operator Information:
Name of the firm, public organization or other entity that operates the facility. (Note that this is not
referring to the Operator in Responsible Charge or ORC)
Name Water Quality Lab and Operations, Inc.
Mailing Address
City
State / Zip Code
Telephone Number
Fax Number
P.O. Box 1167
Banner Elk
NC 28604
(828)898-6277
(828)898-6255
4. Population served: 725
5. Do you receive industrial waste?
1 of 3 Form -A b/2017
NPDES APPLICATION FOR PERMIT RENEWAL - FORM A
For Publicly Owned Treatment Works (POTW) or other treatment systems treating
domestic wastes < 0.1 MOD with no pretreatment program.
0 No ❑ Yes (if you have an approved pre-treatment program, must complete Form 2A)
6. Type of collection system
0 Separate (sanitary sewer only)
7. Out fall Information:
❑ Combined (storm sewer and
Number of separate discharge points 1
Outfall Identification number(s) 001
Is the outfall equipped with a diffuser? ❑ Yes ® No
wale,
Regon�,0 at!',
Reg)onal U fire x
ee -,
S. Name of receiving stream(s) (Provide a map showing the exact location of each outfall):
Cane Creek, French Broad River Basin
9. Frequency of Discharge: Continuous 07 Intermittent
If intermittent:
Days per week discharge occurs: Duration: 'ID m, n fes
10. Describe the treatment system
List all installed components, including capacities, provide design removal for BOD, TSS, nitrogen and
phosphorus. /f the space provided is not sufficient, attach the description of the treatment systern in a
separate sheet of paper.
Submersible influent pump station with dual 350-GPM influent pumps
• Manual bar screen
• Flow Splitter Box
• Flow equalization basin
• Dual (2) each 100,000 gallon Intermittent Cycle Extended Aeration System
(ICEAS)/Sequencing Batch Reactor hybrid process/ dual (2) each 25-HP blowers
(dual (2) each 100-HP motors)
• Three (3) each 0.025 MOD extended aeration package plants converted to
aerobic sludge digestion, thickening, and storage
• Ultraviolet (UV) disinfection [Degremont Technologies Infilco equipment, 8
banks, each with 4 bulbs]
• 2870 gallon post aeration chamber
• Effluent weir/Isco ultrasonic flow measurement
• Back-up power generator (Kohler 60-kW, diesel)
11. Flow Information:
Treatment Plant Design flow 0.200 MGD
Annual Average daily now 0.0947 MOD (for the previous 3 years)
Maximum daily flow 0.9 MMGD (for the previous 3 years)
12. Is this facility located on Indian country?
❑ Yes ® No
2 of 3 Form -A w207
NPDES APPLICATION FOR PERMIT RENEWAL - FORM A
For Publicly Owned Treatment Works (POTW) or other treatment systems treating
domestic wastes < 0.1 MGD with no pretreatment program.
13. Effluent Data
Provide data for the parameters listed. Fecal Coliform, Temperature and pH shall be grab samples, for all other
parameters 24-hour composite sampling shall be used. Effluent testing data must be based on at least three samples
and must be no more than four and one half years old.
Parameter
Daily
Maximum
Monthly
Average
Units of
Measurement
Number of
Samples
Biochemical Oxygen Demand
(BODs)
17.4
10.1
mg/L
140
Fecal Coliform
400
73.48
cuf/ 100mL
140
Total Suspended Solids
32
12.5
mg/L
140
Temperature (Summer)
28
226.4
° C
83
Temperature (Winter)
18
16.6
°C
57
pH
7.7
7.1
s/u
140
14. List all permits, construction approvals and/or applications:
Type
Permit Number
Hazardous Waste (RCRA)
UIC (SDWA)
NPDES NCO025461
PSD (CAA)
Non -attainment program (CAA)
15. APPLICANT CERTIFICATION
Type
NESHAPS (CAA)
Ocean Dumping (MPRSA)
Dredge or fill (Section 404 or CWA)
Special Order of Consent (SOC)
Other
Permit Number
I certify that I am familiar with the information contained in the application and that to the
best of rov knowledge and belief such information is true, complete, and accurate.
J 12,rewur Stc mvo"A
e#,qA .ES l_ , VI"i Es M A�yoP_
name of Person
4E
sigl3piVre of Applicant Date
No Carolina General Statute 143-215.6 (b)(2) states: Any person who knowingly makes any false statement
representation, or certification in any application, record, report, plan, or other document files or required to be
maintained under Article 21 or regulations of the Environmental Management Commission implementing that
Article, or who falsifies, tampers with, or knowly renders inaccurate any recording or monitoring device or method
required to be operated or maintained under Article 21 or regulations of the Environmental Management
Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed
$25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a
punishment by a fine of not more than $25,000 or imprisonment not more than 5 years, or both, for a similar
offense.)
3 of 3 form -A 6017
Water Quality Lab & Operations, Inc.
P.O. Box 1167/ 1522 Tynecastle Highway
Banner Elk, NC 28604
Ph. 828-898-6277 Fax 828-898-6255
TOWN OF BAKERSVILLE WWTP SLUDGE MANAGEMENT
Sludge is managed via a commercial hauler, Triple T located on 1372 NC Hwy 194
N, Boone, NC 28607.
Ally 19 201
water Qu 9
ality Re
Asheville Regional pace ticns
Town of
Bakersville
Incorporated 1870
"Gata,cav to Roan Mountain"
Mayor:
Charles E. Vines
July 30, 2019
Wastewater Branch
Water Quality Permitting Section
Division of Water Resources
1617 Mail Service Center
Raleigh. NC 27699-1617
Subject: Delegation of Signature Authority
Town of Bakersville
NPDES Number NCO02WI
To Whom It May Concern:
Town Council:
Charles Nash
Jordon Baker
Beau Thomas
By notice of this letter, I hereby delegate signatory authority the following individual for
all permit applications, discharge monitoring reports, and other information relating to
the operations at the subject facility as required by all applicable federal, state, and local
environmental agencies specifically with the requirements for signatory authority as
specified in ISA NCAC 2B.0506.
Jadd Brewer
Operations Manager
P.O. Box 1167
1522 Tynecastle Hwy Banner Elk, NC 28604
jaddbrewer@rocketmail.com
828-898-6277
828-260-2027
26 Mitchell Ave 0 PO Box 53 Bakersville NC 28705-0053 0 www.bakersvillene.com
Phone•828fi88-2113 0 Pat 82"88.2745 0 E-mail Address inlia bakersvillenc.wnn
If you have any questions regarding this letter, please feel free to contact me at 828.688-
2113.
Sincerely,
(1-�'�a&f �-.✓'
Charles Knes
Mayor
Town of Bakersville
P.O. Box 53, Bakersville, NC 28705
evines@bakersvillene.com, cvines(:W�mitchell.main.nc.us
828-688-2113
cc: Asheville Regional Office, Water Quality Permitting Section