HomeMy WebLinkAbout20171527 Ver 2_Staff Comments_20200424Strickland, Bev
From: Mcdaniel, Chonticha
Sent: Friday, April 24, 2020 1:16 PM
To: Homewood, Sue
Subject: SW Conditions for Person County Mega Park
The Division approves the Stormwater Management Plan (SMP) consisting of four (4) wet ponds and all associated
stormwater conveyances, inlet and outlet structures, and the grading and drainage patterns depicted on plan sheets
dated April 23, 2020, which are incorporated by reference and are enforceable by the Division. The following conditions
also apply [15A NCAC 02H .0506(b)(5)]:
a) The maximum allowable drainage area and maximum allowable built -upon area within that drainage area for
each of the approved wet ponds shall be as follows:
Wet Pond No.
Max. Drainage Area (sf)
Max. Allowable BUA (sf)
1
1,045,876
264,922
2
3,312,180
2,111, 859
3
1,067,656
567,687
4
779,724
572,915
Any changes to these allowable maximum areas shall require the applicant to submit and receive approval from
the Division prior to any construction or modification of the current site.
b) The footprint of all stormwater management device(s) as well as an additional 10-foot wide area on all sides of
the device(s) shall be located in either public rights -of -way, dedicated common areas or recorded easement
areas. The final plats for the project showing such rights -of -way, common areas and easement areas, shall be in
accordance with the approved plans.
c) The approved SMP shall be constructed and operational before any permanent building or other structure is
occupied at the site.
d) The SMP may not be modified without prior written authorization from the Division.
e) Maintenance activities for stormwater management device(s) shall be performed in accordance with the
notarized O&M agreements signed by Sherry Wilborn (of Person County) on April 23, 2020. The O&M
agreement shall transfer with the sale of the land or transfer of ownership/responsibility for the approved SMP.
The Division shall be notified promptly of every transfer.
f) Upon completion of construction and prior to operation of the approved stormwater control device(s), a
certification from an appropriate designer for the device certifying that it has been installed in accordance with
the approved plans, specifications, and other supporting documentation, shall be submitted to the Division (C/O
Chonticha McDaniel; 1617 Mail Service Center, Raleigh, NC 27699-1617).
g) Additional SMP(s) for future phases must receive written authorization from the Division before any land
disturbance, construction, or expansion of the new phase(s) may occur.
Chonticha McDaniel
401 Stormwater Engineer
401 & Buffer Permitting Branch
Division of Water Resources
Department of Environmental Quality
919-707-3634 office
chonticha.mcdaniela-ncdenr.gov
Mailing Address - 1617 Mail Service Center, Raleigh, North Carolina, 27699-1617
Street Address - 512 N. Salisbury St. (Floor 9th), Raleigh, North Carolina, 27604
0 .....�u,... M..�e... ..o„., ..w.......uoo.........m,,...A....,.00.o..
Email correspondence to and from this address is subject to the
North Carolina Public Records Law and may be disclosed to third parties.