Loading...
HomeMy WebLinkAboutNC0003794_STAFF REPORT_19900202WDES DOCUNKMT SCAMMIMO COVER SWIEET NPDES Permit: NC0003794 Corning - Wilmington Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Speculative Limits taff Report Instream Assessment (67B) Environmental Assessment (EA) Permit History Document Date: February 2, 1990 This docume 3mt im priutesd oia reams pmpesr — igpnore, sag 0<103M a J%t onM they re+'We►X-MO rSicie, • 0 0 Date: February 2, 1990 NPDES STAFF REPORT AND RECOMMENDATIONS County: New Hanover NPDES Permit No. NCO003794 REVIEW ENGINEER: Jule Shanklin PART I -'GENERAL INFORMATION 1. Facility and Address: Corning Incorporated J� 0 b 19�0 Corning, New York 14831 T��M�,w01'kUnr BRANCII 2. Date of Investigation: 1/31/90 3. Report Prepared by: Edward Beck 4. Persons Contacted and Telephone Number: Jerry Orazen (919) 395-7523 5. Directions to Site: Located on the east side of Highway 132, approximately 0.4 miles north of Highway 17 6. Discharge Point - Latitude: 34' 15' 05" Longitude: 770 52' 14" Attach a USGS Map extract and indicate treatment plant site and discharge point on map. USGS Quad No.: or USGS Quad Name: Scotts Hill 7. Size (land available for expansion and upgrading): Site approximately 20 acres 8. Topography (relationship to flood plain included): Elevation approximately 30 ft. MSL 9. Location of nearest dwelling: 200 feet from outfall point 10. Receiving stream or affected surface waters: Spring Branch a. Classification: C-SW b. River Basin and Subbasin No.: 03-06-17 C. Describe receiving stream features and pertinent downstream uses: Urban stream, drains residential areas PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. Type of wastewater: % Domestic 100% Industrial a. Volume of Wastewater: 0.1 MGD b. Types and quantities of industrial wastewater: Non -contact cooling water, bleed -off from water wells C. Prevalent toxic constituents in wastewater: residual from conditioners added to cooling towers d.. Pretreatment Program (POTWs only) in development: approved: should be required: not needed: 2. Production rates (industrial discharges only) in pounds a. highest month in the last 12 months: b. highest year in the last 5 years: 3. Description of industrial process (for industries only) and applicable CYR Part and Subpart: Production of waveguide glass fibers 4. Type of treatment (specify whether proposed or existing): no treatment 5. Sludge handling and disposal scheme: N/A 6. Treatment plant classification: N/A 7. SIC Code: 3229 Wastewater Code: 14, 17 PST III - OTHER —PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grants Funds (municipals only)? 2. Special monitoring requests: 3. Additional effluent limits requests: 4. other: PART IV - EVALUATION AND RECOMMENDATIONS The company produces waveguide fibers which are used for telecommunications and data transmission. Sanitary wastewater is discharged to the City of Wilmington system., When the permit was reissued last time, the company proposed to discharge wastewater from wet scrubbers which were to be part of the air emissions control system. The waste water, which was to contain hydrochloric acid, sodium chloride, suspended solids and small quantities of germanium, was to be treated and discharged to the Northeast Cape Fear River as outfall 003. The company never constructed the outfall and has not discharged this wastewater. The waste is being treated in a manner that does not require a discharge. The company, therefore wishes to delete outfall 003 from the' permit . Outfalls 001 and 002 include non -contact cooling water from cooling towers, air-conditioning condensate, air compressor cooling water, bleed off from wells and roof and yard runoff. Each outfall has an open trough and wier for sample collection and flow measurement. The sampling points look clean and free of oil residue or other nuisance conditions. It is recommended that the permit be reissued containing standard conditions for non -contact cooling water. - - 5_,�z�J 13eel, Signature of Report Preparer Unginai Signed 0y PRESTON HOWA" ,EIS Water Quality Regional Supervisor EB:CORNING.FEB cc: WiRO, CF Technical Services