Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
WQ0007218_Application_19921116
NOV 17199? State of North Carolina ENV. MANAGEMENT Department of Environment, Health and Natural 1�eso���is1l.LE REG. ©FfICF Division of Environmental Management 512 North Salisbury Street - Raleigh, North Carolina 27611 James G. Martin, Governor William W. Cobey, Jr., Secretary November 16, 1992 Bruce Bright, President Woodlake Partners 150 Woodlake Boulevard Vass, N.C. 28394 A. Preston Howard, Jr., P.E. Acting Director Subject: Application No. WQ0007218 Additional Information Request Woodlake Partners Woodlake Country Club Sewer Extension Moore County Dear Mr. Bright: The Permits and Engineering Unit has completed a preliminary engineering review of the subject application. The following items must be addressed before we can complete our review: 1. Please complete the enclosed Operational Agreement (either the Homeowners Association Version or the Developers Version) or provide one of the following: a) Franchise authorizing Woodlake Water and Sewer Company, Inc. to provide sewer service to Woodlake Country Club, b) Certificate of Convenience and Public Necessity authorizing Woodlake Water and Sewer Company, Inc. to provide sewer service to Woodlake Country Club, or c) Letter from the North Carolina Utilities Commission indicating that Woodlake Country Club is contiguous to an existing development for which Woodlake Water and Sewer Company, Inc. is authorized to provide sewer service and that Woodlake Country Club is covered under that authorization. 2. Please identify the number of emergency generators that are available and the number of pump stations which they must serve. Regional Offices Asheville Fayetteville Mooresville Raleigh Washington Wilmington Winston-Salem 704/251-6208 919/486-1541 704/663-1699 919/733-2314 919/946-6481 919/395-3900 919/896-7007 Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer Page 2 Permit No. WQ0007218 November 16, 1992 Refer to the subject permit application number when providing the requested information. Please submit three copies of all information to my attention at the address below. Also, please note that failure to provide this additional information on or before January 16, 1992 will subject your application to being returned as incomplete, in accordance with 15A NCAC 2H .0208. If you have any questions on this matter, please call me at (919) 733-5083 ext. 547. Sincerely, Michael D. Allen Environmental Engineer I State Engineering Review Group cc: Fayetteville Regional Office Permit File WQ0007218 Hobbs, Upchurch & Associates, P.A. II r MEMO TO: State Review Group Division of Environmental Management FROM: M. J. N land• a Fayetteville Regional RegioT Office SUBJECT: Procedure -Four d 11/25/92 WQ00.07218 Date Country Club 4s1171 Sewer Extension -Private Moore County State Review Group Review Engineer Michael Allen Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: Woodlake water & Sewer Co. WwTP 2) WWTP design capacity 1_0 MGD 3) NPDES Permit No.: NC0061719 Expiration Date: 05/31/96 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 10/O1/91 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 30,000 GPD domestic X ; industrial other 6) Volume from previously approved projects not yet tributary to WWTP 0_ GPD 7) Regional Recommendations: Approval X Denial MJN/RR/rr Enclosure NOV 10 1992 ENV. MANAGEMENT State of North Carolina FAYETTEVILLE REG. OFFICE Department of Environment, Health and Natural Resources Division of Environmental Management 512 North Salisbury Street • Raleigh, North Carolina 27604 James G. Martin, Governor George T. Everett,Ph.D. William W. Cobey, Jr., Secretary Director November 6, 1992 MR BRUCE BRIGHT WOODLAKE PARTNERS 150 WOODLAKE BLVD. VASS, NORTH CAROLINA 28394 Subject: Application No. WQ0007218 Country Club Sewers -Private Moore County Dear MR BRIGHT: The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on November 5, 1992. This application has been assigned the number shown above. Please refer to this number when making inquiries on this project. Your project has been assigned to Michael Allen for a detailed engineering review. A technical acknowledgement will be forthcoming. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact Michael Allen at (919) 733-5083. cc: Fayetteville Regional Office Hobbs Upchurch & Associates Sincerely, C1� on SAW, P.E. Supervisor, Permits and Engineering Unit Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer I. State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAYBE PHOTOCOPIED FOR USE AS AN ORIGINAL) GRAVITY SEWER EXTENSION, PUMP STATIONS, AND PRESSURE SEWERS I. GENERAL INFORMATION: 1. Applicant (corporation, individual, or other): Woodlake Partners 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): Bruce Bright, President Woodlake Water and Sewer 3. Mailing Address: 150 Woodlake Boulevard City: Vass State: NC Zip. 28394 Telephone No.: ( 919 ) 245-4386 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): Woodlake Country Club 5. Application Date: September 28, 1992 6. Fee Submitted: $ 400.00 7. County where project is located: Moore II. PERMIT INFORMATION: WQO� 1. Permit No. (will be completed by DEM): / r7 ,--A f� 2. Specify whether project is: x new; renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.9). Submit only pgs. 1, 2, 9 (original and 3 copies of each). Engineer signature not required for renewal. 3. If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit number N/A and issue date N/A 4. Specify whether the applicant is public or x private. FORM: GSPS 4/91 Page 1 of 10 GRAVITY SEWER EXTENSION & PUMP STATION ; PAGE 2 (4/91) III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater. 100 % Domestic; % Commercial; % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: subdivision 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: None 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? N/A 5. Volume of wastewater generated by this project: 30,000 gallons per day 6. Explanation of how wastewater volume was determined: 40 units a $2.5 person/ unit @ 120 gal/day = 12,000. Peak Flow = 2.5 x 12,000 gal/day = 30,000 gal/day IV. DESIGN INFORMATION: 1. Brief project description: 2,041 LF of 8" PVC SDR 35 sanitary sewer, 859 LF of 2" force main, 9 manholes, pump station and appurtenances. 0 Name of wastewater treatment facility receiving wastewater: Woodlake Water a. Facility permit no.: NC 0061719 b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: all downstream sewer lines and outfalls are adequate to accept the proposed flow. 2 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 3 (4/91) 3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C factor or N factor is used and circle C or N below: N Dia.. Length Pipe C or N Min. Max. Minimum Max. Minimum (LL) (Lin. Ft) Material Factor Slope % Slope % Velocity (fps) Vel.(fps) Cover (in) 8" 1991 PVC 0.010 .40 .40 2.84 2.84 36" 8" 50 DIP 0.013 .40 .40 2.19 2.19 36" NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be as follows: a. 36 feet separation for slopes of 21% to 35%; b. 24 feet separation for slopes of 36% to 50%; c. 16 feet separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified - For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? N/A 5. Maximum sewer reach length between manholes: 294 linear feet. 6. This sewer line segment occurs between manhole no. 5 and manhole no. 6 7. Does the owner/operator have the ability to clean this length? x Yes No. 8. Sewer subject to existing or planned traffic bearing loads? x Yes No. If yes, what measures are being taken to enable the sewers to withstand the loads? 9. Outside drop manholes are provided where invert separations exceed: N/A feet. 10. Identify (by manhole number) those manholes that have drop connections: N/A 3 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 4 (4/91) I I _ Maximum allowable infilu=on/exfiltration test rate: 200 GPD/ pipe dia. in./ mile_ Note: Must not exceed 200 GPD/ pipe dia. in./ mile. 12. Minimum separation distances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? x Yes _ No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer specified? x Yes _ No c) 10 ft. horizontal separation from water mains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? x 'Yes —No 13. Are manholes subject to flooding? x Yes —No 14. If yes, are manhole rim elevations 1 foot above 100-year flood level, _ Yes x No (100 year flood elevation should be indicated on plans) 15. Or are manholes watertight and vented 1 foot above the 100-year flood elevation ( should be shown on plans): X Yes —No 16. Identify (by manhole number) those manholes that are vented: Manholes #1-119 17. Does this project involve any stream crossings? _ yes x no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: 4 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 5 of 10 (4/'91) V. PUMP STATION INFORMATION 1. Pump Station No.: 1 (A separate sheet V.1 through V.15 should be submitted for each pump station) 2. Name of closest downslope surface waters: Crains Creek 3. Classification of closest downslope surface waters: WS111 (as established by the Environmental Management Commission & specified on page 6 of this applic.). 4. If a power failure at this pump station could impact waters classified as WS, SA, B, or SB, describe which of the measures are being implemented to prevent such impact, as required in 15A NCAC 2H .0200: Woodlake owns several emergency generators which will be used to supply power. 5. What size pumps are provided? 31.5 GPM 6. How many pumps are provided? I 7. What is the maximum capacity of the pump station? 8. What is the design total dynamic head? 30,000 GPD 43.73 feet - 9. How many pumping cycles will occur at the design flow rate? 10. Check if provided at pump station: Alternate Power Source Wet Well Vented with Screen Fillets in Wet Well Check Valves and Gate Valves Security Fencing Lockable Wet Well Cover Area Light 110V Electrical Convenience Outlet Flood/Buoyancy Protection High Water Alarm yes Audible and Visual yes yes yes yes no yes no yes yes 11. Summary of force main (by diameter size and pipe material): 4 cycles per hour no Auto Dialer Diameter Length Pipe High Low Minimum Maximum Minimum (Inches) (Linear Ft) Material Elevation Elevation Velocity(fps) Vel.(fps) Cover (in) 2 859 PVC 229.50 221 2.12 2.12 15" 12. Are air release valves provided at all high points along the force main (must be provided where the elevation difference exceeds 10 feet)? yes x no 13. Is pump station subject to flooding? yes x no. If yes, what measures are being taken to protect against flooding? manholes will be made watertight and vented above 100-year flood. 14. If subject to flooding, specify the 100-year flood elevation: 228.70 Feet MSL 15. Are there existing or planned pump stations downstream of this station? x yes _ no If yes, the engineer shall evaluate the ability of those pump stations to adequately handle the subject flows. All downstream pump stations are adequately designed to handle the additional flow. GRAVITY SEWER EXTENSION & PUMP STATION PAGE 6 (4/91) TO: REGIONAL WATER QUALITY SUPERVISOR Please provide me with the classification of the surface waters identified in number 5 below and on the attached map segment: Name of surface waters: Crains Creek Classification (as cstablished by the Environmental Management Commission): WSIII Proposed Classification, if applicable: /Y /4 Signature of regional office personnel: W� k-161— Date: INSTRUCTIONS TO ENGINEER In order to determine whether provisions for dual or standby power may be required for the subject facility, the classification of the closest downslope surface waters (the surface waters that any overflow from the facility would flow toward) must be determined. You are required to submit this form, with items 1 through 10 completed, to the appropriate Division of Environmental Management Regional Water Quality Supervisor (see attached listing). At a minimum, you must include an 8.5" by 11" copy of the portion of a 7.5 minute USGS Topographic Map which shows the subject surface waters. You must identify the location of the facility and the closest downslope surface waters (waters for which you are requesting the classification) on the submitted map copy. The application may not be submitted until this form is completed and included with the submittal. 1 2 Applicant (corporation, individual, or other): Woodlake Partners Name and Complete Address of Engineering Firm: Hobbs, Upchurch & Asgociates, P.A. , P.O. Box 1737 City: Southern Pines Telephone No. 3. Project Name: State: NC (919) 692-5616 Greenbriar Road 4. Pump station design flow: 30,000 Zip: 2838 GPD; 31.5 GPM 5. Name of closest downslope surface waters: Crains Creek 6. County(s) where project and surface waters are located: 7. Map name and date: attached 8. North Carolina Professional Engineer's Registration No. 9. Print Name of Engineer David Townsend, III 10. Seal and Signature (specify date): 6 of 10 Moore NC 12655 �t%S�;yg5lt69FR:P; /O� GRAVITY SEWER EXTENSION & PUMP STATION PAGE 8 (4/91) THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and three copies of the completed and appropriately executed application form. b. Three sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, details on the pump station, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the fast page of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or modification. C. Three copies of all calculations, including pump selection, friction calculations, cycle time, pump curves (including system curves applicable with one pump running, two pumps running, three pumps running, etc.), and evaluation of downstream pump stations. These items must be submitted under the signature and seal of the North Carolina Professional Engineer. d. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). e. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. f. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 8 of 10 DIVISION OF ENVIRONMENTAL MANAGEMENT REGIONAL OFFICES (4/91) Asheville Regional WQ Super. Washington Regional WQ Super. Raleigh Regional WQ Super. 59 Woodfin Place P O Box 1507 3800 Barrett Dr., Suite 10i Asheville, NC 28802 Washington, NC 27889 Raleigh, NC 27609 704/251-6208 919/946-6481 919/733-2314 Avery Macon Beaufort Jones Chatham Nash Buncornbe Madison Bertie Lenoir Durham Northampton Bursae McDowell Camden Martin Edgecombe Orange Caldwell Mitchell Chowan Pamlico Franklin Person Cherokee Polk Craven Pasquotank Granville Vance Clay Rutharford Currituck Perquimans Halifax Wake Graham Swain Dare Pitt Johnston Warren Haywood Transylvania Gates Tyrell Lee Wilson Henderson Yancy Greene Washington Jackson Hertford Wayne Hyde Fayetteville Regional WQ Super. Mooresville Regional WQ Super. Wilmington Region. WQ Super, Wachovia Building, Suite 714 919 North Main Street 127 Cardinal Drive Extension Fayetteville, NC 28301 Mooresville, NC 28115 Wilmington, NC 28405-3845 919/486-1541 704/663-1699 919/395-3900 Anson Moore Alexander Mecklenburg Brunswick New Hanover Bladen Robeson Cabamu Rowan Carteret Onslow Cumberland Richmond Catawba Stanly Columbus Pender Harnett Sampson Gaston Union Duplin Hoke Scotland Iredell Cleveland Montgomery Lincoln Winston-Salem Regional WQ Super. 8025 North Point Boulevard, Suite 100 Winston-Salem, NC 27106 919/161-2351 Alamance Rockingham Alleghany Randolph Ashe Stokes Caswell Story Davidson Watauga Davie Wilkes Forsyth Yadkin Guilford 7of10 • - GRAVITY SEWER EXTENSION & PUMP STATION PAGE 10 (4/91) PERMIT APPLICATION PROCESSING FEES (effective October 1, 1990) CATEGORY NEW APPLICATIONS/ RENEWALS WITHOUT MODIFICATIONS MODIFICATIONS > 1,000,000 GPD Industrial $400 $300 Domestic/Cooling Water $400 $300 10,001 - 1,000,000 GPD Industrial $400 $250 Domestic/Cooling Water $400 $250 1,001 - 10,000 GPD Industrial $400 $200 Domestic/Cooling Water $400 $200 < or = 1,000 GPD and Single Family Dwelling $240 $120 Sludge < or = 300 Acres $400 $250 Sludge > 300 Acres $400 $250 Sewer Extensions (nondelegated) $400 0 Sewer Extensions (delegated) $200 0 Closed -Loop Recycle or Evaporative $400 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer Extension Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Division of Environmental Management. 10 of 10 GRAVITY SEWER EXTENSION & PUMP STATION PAGE 9 (4/91) Name and Complete Address of Engineering Finn: Hobbs, Upchurch & Associates, P.A, P.O. Box 1737 City: Southern Pines State: NC Zip: 27388 Telephone No. (919) 692-5616 Professional Engineer's Certification: I, David Townsend, III , attest that this application for Greenbriar Road for -Woodlake Water & Sewer Company has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. . North Carolina Professional Engineer's Registration No. 12655 Print Name of Engineer David Townsend, III Seal and Signature (specify date): E 12 e Applicant's Certification: I, Bruce Bright ,attest that this application for Greenbriar Road for Woodlake Water & Sewer Company has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. n Signature Date < <`- 7- THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DMSION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: 919/733-5083 9 of 10