Loading...
HomeMy WebLinkAboutWQ0002086_Application_199303311 APR 1 1993 =� NAGEMENT ~j FAYETTEVIL E REG. OFFICE State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management 512 North Salisbury' Street • Raleigh, North Carolina 27604 James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary March 31, 1993 MR MITCH COLEMAN MOORE CO WATER & SEWER AUTHORITY PO BOX 726 CARTHAGE, NORTH CAROLINA 28327 Dear MR COLEMAN: A. Preston Howard, Jr., P.E. Director Subject: Application No. WQ0002086 Front Street Area Name Change Moore County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on March 30, 1993. This application has been assigned the number shown above. Please refer to this number when making inquiries on this project. Your project has been assigned to John Kuske for a detailed engineering review. A technical acknowledgement will be forthcoming. Be aware that the Division's regional office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the Division. If you have any questions, please contact John Kuske at (919) 733-5083. cc: Fayetteville Regional Office Sincerely, C CL�L S t, P.E. Supervisor, ermits and Engineering Unit Pollution Prevention Pays P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer l State of North Carolina Department of Environment, Health, and Natural Resources Division of Environmental Management Non -Discharge Permit Application (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORIGINAL) . GRAVITY SEWER EXTENSION I. GENERAL INFORMATION: 1. Applicant (corporation, individual, or other ): MoorP warms c gPwer AutherityT Beard of Directors 2. Print Owners or Signing Official's Name and Title (the person who is legally responsible for the facility and its compliance): Mi toh rnl Aman 3. Mailing Address: City: Carthage State: N.r Zip: M227 Telephone No.: 9( 19 ) 947-6315 4. Project Name (subdivision, facility, or establishment name - should be consistent with project name on plans/specs., letters of flow acceptance, Operational Agreements, etc.): Front Street Area Town of Vass 5. Application Date: 3/21/93 6. Fee Submitted: $100.00 7. County where project is located: Moore H. PERMIT INFORMATION: TRANSFER OF OWNERSHIP 1. Permit No. (will be completed by DEM): k )a coo b o_ 2. Specify whether project is: new; ` renewal*; modification. *If renewal, complete only sections I through III and applicant signature (on pg.5). Submit only pgs. 1, 2, 5 (original and 3 copies of each). Engineer signature not required for renewal. 3. If this application is being submitted as a result of a renewal or modification to an existing permit, list the existing permit numberWQ0002086 and issue date-912J-L89 4. Specify whether the applicant is X public or private. FORM: GSEA 4/91 Page 1 of 6 `GRAVITY SEWER EXTENSION - - PAGE 2 (4/91) III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater: % Domestic; % Commercial; % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital, commercial, industrial, apartments, etc.: 3. Indicate any parameter (and its concentration) that will be greater than normal domestic levels: 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? 5. 6. Volume of wastewater generated. by this project: Explanation of how wastewater volume was determined: IV. DESIGN INFORMATION: 1. Brief project description: 2. Name of wastewater treatment facility receiving wastewater: a. Facility permit no.: gallons per day b. Engineer should provide statement of his evaluation of downstream sewers to accept the wastewater: 2of6 i GRAVITY SEWER EXTENSION PAGE 3 (4/91) 3. Summary of sewer pipe by diameter size and pipe material. Indicate here whether C factor or N factor is used and circle C or N below: Dia. Length Pipe C or N Min. Max. Minimum Max. Minimum (In.) (Lin. Ft) Material Factor Slope % Slope % Velocity(fps) Vel.(fps) Cover (in) NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be as follows: a. 36 feet separation for slopes of 21% to 35%; b. 24 feet separation for slopes of 36% to 50%; c. 16 feet separation for slopes of 50% and greater. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion control measures must be specified For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? 5. Maximum sewer reach length between manholes: linear feet. 6. This sewer line segment occurs between manhole no. and manhole no. 7. Does the owner/operator have the ability to clean this length? Yes No. 8. Sewer subject to existing or planned traffic bearing loads? Yes No. If yes, what measures *are being taken to enable the sewers to withstand the loads? 11 9. Outside drop manholes are provided where invert separations exceed: feet. 10. Identify (by manhole number) those manholes that have drop connections: 3of6 GRAVITY SEWER EXTENSION PAGE 4 (4/91) 11. Maximum allowable infiltration/exfiltration test rate: dia. in./ mile. Note: Must not exceed 200 GPD/ pipe dia. in./ mile. GPD/ pipe 12. Minimum separation distances as shown on the plans or addressed in the specifications: a) 100 ft. horizontal separation from wells or other water supplies? _ Yes — No b) 12 in. vertical separation from storm sewer or ferrous pipe yes —No sanitary sewer specified? — c) 10 ft. horizontal separation from water mains or 18 in. vertical separation (water over sewer) or ferrous pipe specified? —Yes —No 13. Are manholes subject to flooding? —Yes _No 14. If yes, are manhole rim elevations 1 foot above 100-year flood level, —Yes —No (100 year flood elevation should be indicated on plans) 15. Or are manholes watertight and vented 1 foot above the 100-year yes No flood elevation ( should be shown on plans): — — 16. Identify (by manhole number) those manholes that are vented: 17. Does this project involve any stream crossings? — yes — no. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and three copies of the completed and appropriately executed application form. b. Three sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans must include a general location map, a plan view of the sewer extension, a profile of the sewer extension, and must show the proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegated authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Three copies of the existing permit if a renewal or modification. c. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). d. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a -recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. e. An Operational Agreement (original and two copies) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. 4of6 1 � f Name and Complete Address of Engineering Firm: City: State: Telephone No. Professional Engineer's Certification: I, GRAVITY SEWER EXTENSION PAGE 5 (4/91) , attest that this application for Zip: has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Registration No. Print Name of Engineer Seal and Signature (specify date): Applicant's Certification: I, Mitch Coleman , attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned as incomplete. 0 Signature Date THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 512 NORTH SALISBURY STREET RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: 919/733-5083 5of6 GRAVITY SEWER EXTENSION PAGE 6 (4/91) PERMIT APPLICATION PROCESSING FEES (effective October 1,1990) CATEGORY NEW APPLICATIONS/ RENEWALS WITHOUT MODIFICATIONS MODIFICATIONS > 1,000,000 GPD Industrial Domestic/Cooling Water 10,001 - 1,000,000 GPD Industrial Domestic/Cooling Water 1,001 - 10,000 GPD Industrial Domestic/Cooling Water < or = 1,000 GPD and Single Family Dwelling Sludge < or = 300 Acres Sludge > 300 Acres Sewer Extensions (nondelegated) Sewer Extensions (delegated) Closed -Loop Recycle $400 $400 $400 $400 $240 $400 $400 $400 $200 $300 $300 $250 $250 $200 $200 $120 $250 $250 0 0 or Evaporative $400 $200 NOTE: The Fees for Soil Remediation Projects are the same as for Sludges. Under the Sewer Extension Fee, "delegated to municipalities" applies only to those governmental jurisdictions that have specific delegation review. authority, as granted by the Division of Environmental Management. 6of6