Loading...
HomeMy WebLinkAboutWQ0010828_Permit (Issuance)_19950508June 19, 1996 ROY L. RAMEY,MAYOR VASS, TOWN-LINCOLN AVE REVITA PO BOX 487 VASS, NC 28394 SUBJECT: CERTIFICATE OF COMPLETION PERMIT NO. WQ0010828 VASS, TOWN-LINCOLN AVE REVITA MOORE COUNTY Dear Permittee: On May 08, 1995 the Division of Environmental Management issued you the subject permit. One of the conditions of the subject permit read as follows: Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with the requirements of this permit and the approved plans and specifications. Mail certification to the Permits and Engineering Unit, P.O. Box 29535, Raleigh, N.C., 27626-0535. To date, our records show tha:.. no certification has been received for the subject permit. If the permitted facility has been constructed and placed into operation please submit the required certification immediately. Operation of the treatment system prior to submission of the required certification is in violation of your permit and is subject to enforcement action. If you have any questions, please contact your consulting engineer for this project, HOBBS UPCHURCH & ASSOC at (910)692-5616. If the facility has not been constructed, please contact the Fayetteville Regional Office at (919)486-1541, so that they can update their records. Thank you for your prompt attention to this matter. Sincerely, Carolyn McCaskill, Supervisor State Engineering Review Group cc: File Fayetteville Regional Office State'of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director May 8, 1995 The Honorable Roy L. Ramey, Mayor Town of Vass Post Office Box 487 Vass, North Carolina 28394 Dear Mayor Ramey: 09WAA IT A&4 - - - - !Ll EDEHNI=1 Subject: Permit No. WQ0010828 Town of Vass Lincoln Avenue Revitalization Sewer Extension Moore County In accordance with your application received March 27, 1995, we are forwarding herewith Permit No. WQ0010828, dated May 8, 1995, to the Town of Vass for the construction and operation of the subject wastewater collection extension. This permit shall be effective from the date of issuance until rescinded and shall be subject to the conditions and limitations as specified therein. If any parts, requirements, or limitations contained in this permit are unacceptable, you have the right to request an adjudicatory hearing upon written request within thirty (30) days following receipt of this permit. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, P.O. Drawer 27447, Raleigh, NC 27611-7447. Unless such demands are made this permit shall be final and binding. One set of approved plans and specifications is being forwarded to you. If you need additional information concerning this matter, please contact Mr. Michael D. Allen at (919) 733-5083 ext. 547. cc: Moore County Health Department Fayetteville Regional Office, Water Quality Section Hobbs, Upchurch & Associates, P.A. Sincerely, z1 Al. Prest Howard, Jr., P.E. ttECETVEn MAY 18 " P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENVIRONMENT, HEALTH AND NATURAL RESOURCES RALEIGH WASTEWATER COLLECTION PERMIT In accordance with the provisions of Article 21 of Chapter 143, General Statutes of North Carolina as amended, and other applicable Laws, Rules, and Regulations PERMISSION IS HEREBY GRANTED TO THE Town of Vass Moore County FOR THE construction and operation of approximately 5,407 linear feet of 8-inch gravity sewer, an 80 GPM pump station with duplex pumps, high water alarms, emergency generator, and approximately 1,371 linear feet of 4-inch force main to serve twenty-two (22) 3-bedroom homes in the Lincoln Avenue Revitalization, and the discharge of 7,920 GPD of collected domestic wastewater into the Moore Water and Sewer Authority's existing sewerage system, pursuant to the application received March 27, 1995, and in conformity with the project plan, specifications, and other supporting data subsequently filed and approved by the Department of Environment, Health and Natural Resources and considered a part of this permit. This permit shall be effective from the date of issuance until rescinded and shall be subject to the following specified conditions and limitations: 1. This permit shall become voidable unless the facilities are constructed in accordance with the conditions of this permit, the approved plans and specifications, and other supporting data. 2. This permit is effective only with respect to the nature and volume of wastes described in the application and other supporting data. 3. The facilities must be properly maintained and operated at all times. 4. The sewage and wastewater collected by this system shall be treated in the Moore Water and Sewer Authority Wastewater Treatment Facility prior to being discharged into the receiving stream. 5. This permit is not transferable. In the event there is a desire for the facilities to change ownership, or there is a name change of the Permittee, a formal permit request must be submitted to the Division of Environmental Management accompanied by an application fee, documentation from the parties involved, and other supporting materials as may be appropriate. The approval of this request will be considered on its merits and may or may not be approved. 6. Construction of the sewers, pump station(s) and force main shall be scheduled so as not to interrupt service by the existing utilities nor result in an overflow or bypass discharge of wastewater to the surface waters of the State. 7. Upon completion of construction and prior to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed in accordance with this permit, the approved plans and specifications, and other supporting materials. Mail the Certification to the Water Quality Permits and Engineering Unit, P.O. Box 29535, Raleigh, NC 27626-0535. 8. A copy of the approved plans and specifications shall be maintained on file by the Permittee for a minimum of five years from the date of the completion of construction. 9. Failure to abide by the conditions and limitations contained in this permit may subject the Permittee to an enforcement action by the Division of Environmental Management, in accordance with North Carolina General Statute 143-215.6(a) to 143-215.6(c). 10. The issuance of this permit does not preclude the Permittee from complying with any and all statutes, rules, regulations, or ordinances which may be imposed by other government agencies (local, state, and federal) which have jurisdiction. 11. The Permittee shall provide for the pump station and force main the following items: a. Pump on/off elevations located so that 2-8 pumping cycles may be achieved per hour in the pump station, b. An air relief valve located at all high points along the force main, c. A screened vent for the wet well, d. Fillets located in the wet well at the intersection of the flooring and sidewalls, e. Three feet of cover (minimum) over the force main or the use of ferrous material where three feet cannot be maintained, f. Sufficient devices which will protect the pump station from vandals, and g. Flood protection if the pump station is located below the 100-year flood elevation. 12. In the event that the facilities fail to perform satisfactorily, including the creation of nuisance conditions, the Permittee shall take immediate corrective action, including those as may be required by this Division, such as the construction of additional or replacement wastewater collection facilities. 13. NONCOMPLIANCE NOTIFICATION: The Permittee shall report by telephone to the Fayetteville Regional Office, telephone number (910) 486-1541, as soon as possible, but in no case more than 24 hours or on the next working day following the occurrence or first knowledge of the occurrence of either of the following: a. Any process unit failure, due to known or unknown reasons, that renders the facility incapable of adequate wastewater transport, such as mechanical or electrical failures of pumps, line blockage or breakage, etc.; or b. Any failure of a pumping station or sewer line resulting in a by-pass directly to receiving waters without treatment of all or any portion of the influent to such station or facility. Persons reporting such occurrences by telephone shall also file a written report in letter form within 15 days following first knowledge of the occurrence. This report must outline the actions taken or proposed to be taken to ensure that the problem does not recur. 14. This permit shall become voidable unless the agreement between the Town of Vass and the Moore Water and Sewer Authority for the collection and final treatment of wastewater is in full force and effect. Permit issued this the eighth day of May, 1995 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION A. Preston oward, Jr., P.E., Director Division of -Environmental Management By Authority of the Environmental Management Commission Permit Number WQ0010828 Permit No. WQ0010828 May 8, 1995 ♦ •♦ I, , as a duly registered Professional Engineer in the State of North Carolina, having been authorized to observe (periodically, weekly, full time) the construction of the project, Project Name Location for the Permittee hereby state that, to the best of my abilities, due care and diligence was used in the observation of the construction such that the construction was observed to be built within substantial compliance and intent of this permit, the approved plans and specifications, and other supporting materials. Signature Date Registration No. 2 Wi MEMO TO: State Review Group FROM: Ricky Revels P L3 g, Environmental Technician IV SUBJECT: Procedure Four (4) WQ0010828 Lincoln Ave. Revitalization Sewer Extension - Private MOWASA/Town of Vass Moore County Division of Environmental Management Fayetteville Regional Office 4/27/95 Date State Review Group Review Engineer Buzz Crosby Regional Office Contact Ricky Revels 1) Name of wastewater treatment plant to receive the wastewater: Town of Vass Wastewater Treatment Plant 2) WWTP design capacity 0.060 MGD 3) NPDES Permit No.: NC0074373 Expiration Date: 5 31 96 4) Compliance Information: Present treatment plant performance for previous 12 months - beginning 3194 (See attached self -monitoring data) 5) Quantity and type of wastewater from proposed sewers: 7,920 GPD domestic 100% industrial other 6) Volume from previously approved projects not yet tributary to WWTP 28,400 GPD 7) Regional Recommendations: Approval X Denial RR/rr Enclosure GKEXBB/MF:' COMPLIANCE EVALUATION ANALYSIS REPORT O4/26/95 PAGE i PERMIT--NCO074373 PIPE--00i REPORT PERIOD, 9403-9502 LOC--- E FACILITY--MOORE WATER AND SEWER AUTH. DESIGN FLOW-- .0600 CLASS--2 LOCATION--VASS REGION/COUNTY--06 MOORE 50050 803i0 00530 006i0 316i6 50060 000i8 0040O MONTH Q/MGD BOD RE%/T%% NH3+NH4- FEC COLI CHLORINE TEMP PH LIMIT F .0600 F 30.00 F 30.0 NOL F 200.0 NOL NOL 9.0 6.0 94/03 .0033 3.78 3.0 .15 40.3 .386 13.69 7.7-6.3 94/04 .0025 6.07 4.8 is 4i.3 .327 i9.04 7.5-6.8 /05 .0027 3.20 2.6 1.03 ii.9 .375 2i.45 7.8-6.7 /06 .0022 3.60 3.2 .i4 10.O 25.66 7.2-6.5 94/07 .00i8 2.75 2.0 .16 i0.0 26.50 7.i-7.0 94/08 .0022 3.26 2.4 .i5 ii.6 25.00 7.1-6.4 94/89 .003i 2.75 2.8 .15 i9.0 06.666 22.75 7.3-6.8 /10 .0023 2.25 4.4 .29 9.5 388.46i 18.25 7.2-6.7 /ii .0046 4.86 6.0 1.08 26.6 346.153 17.60 7.i-6.7 02 .0042 4.20 4.2 .34 i5.3 363.636 14.80 7.3-7.1 5/01 .0046 7.15 4.5 i.39 28.i 393.333 12.25 7.3-7.1 5/02 .0045 8.i0 7.9 i.25 9}.7 09.230 iO.25 7.1-7.0 AVERAGE .803i 4.33 3.9 .52 26.2 247.6i8 i8.88 --_ MAXIMUM .0241 ii.30 ii.6 2.7i i2800.0 700.000 26.00 7.800 INIMUM .0086 1.40 2.0 .i0 3.8 .150 8.00 6.300 UNIT' MGD MG/L MG/L MG/L 0/100ML UG/L DEG.0 %U GKEX88/MP , 04/26/95 COMPLIANCE EVALUATION ANALYSIS REPORT PAIE 2 PERMIT--NC0074373 PIPE--00i REPORT PERIOD: 9403-9502 LOC--- E FACILITY--MOORE WATER AND SEWER AUTH. DESIGN FLOW-- .0600 CLASS--2 | LOCATION --VASE REGION/COUNTY--06 MOORE 00600 0866� MONTH TOTAL N PHO%-TOT NOL NOL � 94/03 36.000 2.8000 � 94/O4 94/05 94/06 51.400 3.9000 94/07 � 94/08 � 94/09 4i.500 3.9000 � 94/i0 | 94/12 9.900 i.800O � 95/0i �95/02 AVERAGE 34.475 3.i000 MAXIMUM 51.400 3.9000 MINIMUM 9.000 i.8000 UNIT MG/L MG/L