Loading...
HomeMy WebLinkAboutWQ0041575_Application (FTSE)_20200320DocuSign Envelope ID- F2CD0666-440DAD58-9A7B. 5C46FDF45FAt —4 b State of North Carolina nWR Department of Environmental Quality Division of Water Resources 15A NCAC 02T .0300— FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: W q00 l� J �(to he completed by DWR) V All items most be comnleted or the application will be returned 1. APPLICANT INFORMATION: I. Applicant's name: South Granville Walerand Sewer Authority (company, municipality, HOA, utility, etc,) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Scott Schrover per 15A NCAC 021' 0 M,(Ab'r Title: Executive Director it 4'D 4. Applicant's mailing; address: 415 Central Ave City: Butner State: NC 7.ip: 27509- 5. Applicant's contact information:PC �? Phone number: (919) 575-3367 Email Address: sschroyer(a�sgwasa ore ca c 3 H. PROJECT INFORMATION: o ti I. Project name: U-6020 0 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00__ and issued date: Nei A If new construction but part of master plan, provide the existing permit number: WQ00 3. County where project is located: Granville 4. Approximate Coordinates (Decimal Degrees): Latitude: 36.149005" Longitude-78.726235- 5. Parcel ID (if applicable): (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer. Clint Stevens License Number: 040370 Firm: Winde Engineering Mailing address: 401 1larrison Oaks Blvd. City. Cary State: NC Zip: 27513 Phone number. 9( 19) 653-0001 Email Address: cstevensCd-hindeengineering.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: SGWASA Permit Number: NCO026824 Owner Name: SGWASA V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): L Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch System Wide (.'olicction System Permit Number{s) {ifap1dicabluj: WQCS00068 Owner Nanre(s): SGWASA FORM: FTA 04-16 Page I of 5 DocuSign Envelope ID: FM00666.440D-4068-WS 5C46FDF45FA1 Vl. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No ®NIA 2. If the Applicant is a Developer of lots to be sold, has a DevelojX s C erdtional Agreement t FORM! DL V I been attached? ❑ Yes ❑No ®NIA 3. if the Applicant is a HorneiPmncsrty Owners' tlsrciation- lrps au Unerational Agreement F R1L1: HDA been attached? ❑ Yes [:]No ®N/A 4. Orrin of wastewater. (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ® Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool (Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming PoollFilter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 0 % Domestic/Commercial 100 ° o Commercial % Industrial See 15A NCAC 02-F .01.03{?01) ioIs there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 15A NCAC 021 .0 1 14(t}? ❑ Yes ® No > If ves, Provide n cow of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see PTLO1140 Daily Design Flow ".1' No. of Units Flow gall GPD gall GPD gal/ GPD gall GPD gall GPD gal/ GPD Total GPD a Sec 15A NCAC 02T .01 141b1, fd), (c}(l 1 and (s}t2 For caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in C.S. 4?A-4). b Per 15A NCAC 02T.0I14(c), design flow rates for establishments not identified [in table 15A NK,AC: 021'.01,141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. S. Wastewater generated by project: 0 GPD (per II SA NCAC 02T .01 14) Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ® Flow has already been allocated in Permit Number: WOCS 00068 ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: iTA 04-16 Page 2 of5 DocuSign Envelope ID F2CDO666-44oD4D68-9A7H-5046FdF45FAt VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T _11305 & MDC�Crayity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8" 314 PVC, SDR 35 :- Section 11 & III ofthe MDC for Permitting of Gravity Sewers contains information related to design criteria 1- Section III contains information related to minimum slopes for gravity sewer(s) Z Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC Vill. PUMP STATION DESIGN CRITERIA (If Applicable)—t12-f .0305 & MIX' (Pump Stations,'l:orce Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name. 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) I Length (feet) I Material 6. Power reliability in accordance with 15A NCAC 02 F _0305(hX1): ❑ Standby power source or pump with automatic activation and telemetry - I SA NCAC 02T .0305(h)(l)(13)_ > Required for all pump stations with an average daily Flow greater than or equal to 15,000 gallons per day > Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): > It shall be demonstrated to the Division that die portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timefmmes, shall be provided in the case of a multiple station power outage. FORM: FTA 044-16 Page 3 of 5 DocuSign Envelope ID: F2CDO666-44OD-4DG8-gA7&SC46FDF45FA1 IX. SETBACKS& SEPARATIONS—(02B.0200 & 15A NCAC 02T.0305(t)): I. Does the project comply with all separations found in 15 NCAC 2 _4 & ® Yes ❑ No > 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer) 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet "*Any private or public water supply source, including any wells, WS-I waters of Class 1 or Class Il impounded reservoirs used as a source of drinkin ■ water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, FIQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet "Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Anv building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical hei 2ht 10 feet Drainages stems and interceptor drains 5 feet Any swimming pools 10 feet Final earth prade (vertical) 36 inches 15A NCAC 0?F.03051t;1 contains alternatives where separations in O i'.[1 0sil cannot be achieved. > "*Stream classifications can be identified using the Division's NC Surface 1Vater Classifications webnaue > If noncompliance with 0?T.0303if] or (Kl, see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) [--]Yes [:)No ®NiA i Seethe Division's draft separation requirements for situations where separation cannot be meet Y No variance is required if the alternative design criteria specified is utilized in design and construction As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 07B .0200? ❑ Yes ❑ No 10 MA This would include Trout Buffered Streams per 1- A NCAC 2B.0303 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? i Information can be obtained from the 401 & Bufler Permitting_Hranoh 5. Does project comply with IIiA NCAC 02T.0101(c06) (additional permits/certifications)? ® Yes ❑ No Per 15A.NCAC 02T.Ql0_%t;J 6t, directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 021.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streamtatnks that is subject to erosion that undermines or deteriorates die sewer. ❑ Yes ®No ❑ N?A ;- If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority linesshall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 • DocuSign Envelope ID- F2CD0666-440D-4D68.9A78-5C46FDF45FA1 X. CERTIFICATIONS: 1. Does the submitted system comply with 15A NCAC 023, the Minimum Design Criteria for the Permitting of Pump Stations and l•orce Mains (latest version), and the Gravitv Sewer Minimum -Design Criteria latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal orthe Fast Track Application and supporting documents. 2. Professional Engineer's Certification: Clint L. Stevens _ _ attest that this application for (Professional Engineer's name from Application Item Ill. I.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best ofmy knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and sea] signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE - In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: CARo",,� r QVQ.rpF Essr. _ SEAL o.r .r1,.,1. 3. Applicant's Certification per 15A NCAC 02T .0106(b): 10/24/2019 Scott Schroyer, Executive Director _.attest that this application for (Signature Authority's name & tide from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. 1 understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required pans of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: jw/ Date: FORM: FTA 04-16 Page 5 of 5 �J ENGHI�NEDE March 16, 2020 NCDEQ — Water Quality Section ]TCDept ofpnvironm,,tp+ Raleigh Regional Office QI�I�IIIi 3800 Barrett Drive Raleigh, NC 27609 MAR 2 0 2020 w Subject: Wastewater Collection System Fast Track Application U-6020 West Lyon Station Road, Granville County �� Reg1Qn�� ��� 8-inch Sanitary Gravity Sewer along West Lyon Station Road realignment I am submitting this cover letter and supporting documentation for an 8-inch sanitary gravity sewer along the West Lyon Station Road realignment. The sewer line construction is a result of the roadway improvements for the NCDOT U-6020 (West Lyon Station Road) Project. The project consists of the 314 linear feet of 8-inch Gravity Sewer (PVC SDR 35) being installed to maintain service to a business that is losing current access to the existing gravity sewer that is being removed due to conflict with the roadway project. There are no new customers, no increased demand, and there are no pump stations being affected/relocated. This package includes the following: 1. Cover Letter 2. Permit Application 3. Application Fee 4. USGS Map and Street Level Map If you have any questions or need additional information, please give me a call. Sincerely, Jordan Chapman Designer Hinde Engineering, Inc. I linde Engineering. Inc. 401 1larrison Oaks 131vd., Suite 220 Cary. North Carolina 27513 Phone: 919-653-0001 Ftm 704-814-9042 a m.hindeengineering.com AJ ENGHI�NEDE 401 Harrison Oaks Blvd. Suite 220 Cary, NC 27513 Phone: (919) 653-0001 Fax: (704) 814-9042 LETTER OF TRANSMITTAL To: Raleigh Regional Office Date: NCDEQ — Water Quality Section 1628 Mail Service Center Raleigh, NC 27699-1628 Re: U-6020 West Lyon Road (Granville County) am sending you the following item(s): =Deptofavironmental Quxlitt MAR 2 0 2020 x. Weigh Regional Office March 16, 2020 ,lob No, - A2017705.00 Item # Date Quantity Description 1 3-16-20 2 U-6020 Cover Letter 2 3-16-20 2 U-6020 Fast Track Application 3 3-16-20 1 $480 Application Fee 4 3-16-20 2 U-6020 Site Maps Aerial & To 0 These are transmitted as checked below. ❑ As requested ® For approval ❑ For review and comment Remarks: ❑ For your use ❑ For Signatures Copy to: File Signed: Jordan Chapman Designer M dqd'jaNnssl6lydlwoa•Noddns6ulddewp:sdp4 v(3sn 'Vd3 'vsvNl113w 'SJSf1 d 1N3W380Nl 'uluue9 'B83H `qs3 '100 eLllo1e0 VON 10 a}ejS 'A4unoC) alliAueaO we4an0 Jo Al 0 I qs1 ; AA pei %.J b06041'8L-'9196b1'4E JaluaO L ,� , uaoo•poddns6uiddeua V- �su unno JnoA 3e asn - g• 4A aaj.msSIJ u 0001 , ■ 'i�t 1 _ v 1 •err '• Al >� .� � �� �� r"r�tF.^yJ l �� � '' � ♦ •• r `ter 5 _a'� — •� JaMaS Aj!ASJE) S;6 2i0S '�/1d ..8 'dad r 'J.•�r - %� 1• i j Jai w p RW£!IE i 9K w8 --�-. % �f • • • ' } a 0, + Avsn dol pauueas IZ:IS3 woo'Uoddns6ulddew woo jajunsglE) Aq paonpoid dew 6 LOZ19EIS 2 Va . cl �y�h.Sint,On R7 -- ifl� A III � . 3 rn ro Y m I 0 a i 0 ' r R. La- S ■