Loading...
HomeMy WebLinkAboutWQ0041622_Application (FTSE)_20200415and�ccipe circhlfeclure I plunninq TRANSMITTAL I enginrerinq RECEIVEDINC:D15-NRYDWR POO Date: March 12, 2020 WQROS MOORESVILLE REGIONAL 01PPIC E. Reference: 00639.03 Atrium Providence FSED - Private Sewer Permit Attention: Barry Love Company: NCDEQ Mooresville Regional Office 610 East Center Avenue, Suite 301 Mooresville, NC 28115 Transmitting: 1- Fast Track Application with a copy 1- Engineers narrative 1- USGS Map 1 -Aerial Map 1 - Flow Acceptance Letter 1 - Business license confirmation Transmitted Via: ..-k-dEx- VIa„Ci Tl el.4w- Comments: Please call (803-513-4734) or email (dklausman@bloc-nc.com) me with any questions you may have. By: David S. Klausman Bloc Design, PLLC CC: W. Larry Lockhart, Jr. PE, CMCSI - BD Bloc Design 2923 South Tryon St., Suite 320 Charlotte, NC 28203 704.940.2883 www.bloc-nc.com March 12, 2020 North Carolina Department of Environmental Quality Division of Water Resources 610 East Center Avenue Suite 301 Mooresville, North Carolina 28115 Re: 00639.03 — Atrium Providence FSED (FTA Cover Letter) To Whom It May Concern, The referenced project located at 11516 Providence Road, Charlotte, NC is a proposed Free Standing Emergency Department. The proposed building will connect to an existing private sewer. An existing private permit could not be located for this site as it serves multiple buildings. This application is to permit the existing sewer line that was permitted and installed sometime between 2002 and 2003. Approximately 746 If of 8" gravity sewer will be permitted as part of this application. The anticipated flow to the existing sanitary sewer system will be 3,000 gallons per day. This package includes the completed FTA 04-16 form, USGS topographic map, aerial, and flow acceptance letter. Upon your review of the enclosed information, please feel free to contact me for further discussion. Regards, David S. Klausman, PE Bloc Design, PLLC NC Firm: P-1007, C-390 803-513-4734 dsk cc: Mr. W. Larry Lockhart, Jr., PE — BD SEAL 35711 ����•••�NGIN E;f;: S' The Beck Group Bloc Design 00639.03 - Providence Road FSED 2923 South Tryon St, Suite 320 Charlotte, North Carolina Charlotte, NC 28203 704.940.2883 www.bloc-nc.com State of North Carolina Department of Environmental Quality _DWR Division of Water Resources IV 1W 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION C'PVE&NCI)ENR/DWR Application Number: (to be completed by DWR) MAR 12 "020 All items must be completed or the application will be returned WQROS L APPLICANT INFORMATION: MOORESVILLE REGIONAL OFFICE 1. Applicant's name: Beck Architecture (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Shaun Atkinson per 15A NCAC 02T .0106(b) Title: Project Manager 4. Applicant's mailing address: 4777 Sharon Road, Suite 500 City: Charlotte State: NC Zip: 28210- 5. Applicant's contact information: Phone number: (980) 406-9899 Email Address: ShaunAtkinsongbeckgroup com II. PROJECT INFORMATION: 1. Project name: Atrium Providence FSED 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ00 and issued date: If new construction but part of a master plan, provide the existing permit number: WQ00 3. County where project is located: Mecklenburg 4. Approximate Coordinates (Decimal Degrees): Latitude: 35.0523' Longitude:-80.7707' 5. Parcel ID (if applicable): 22917108 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: David S. Klausman License Number: 35711 Firm: Bloc Design, PLLC Mailing address: 2923 S. Tryon St, Suite 320 City: Charlotte State: NC Zip: 28203- Phone number: (803) 513-4734 Email Address: dklausman@bloc-nc.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: McAlpine Creek Permit Number: NCO024970 Owner Name: Charlotte Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ Downstream (Receiving) Sewer Size: inch System Wide Collection System Permit Number(s) if applicable): WQCS Owner Name(s): FORM: FTA 04-16 Page 1 of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [:]Yes [:]No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes []No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement (FORM: HOA) been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ® Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: % Domestic/Commercial 100 % Commercial % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ® No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f)? ❑ Yes ®No ➢ If yes, provide a copy of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(f)) Daily Design Flow',b No. of Units Flow Free Standing Emergency Department 300 gal/bed 10 3000 GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 3000 GPD a See 15A NCAC 02T .0114(b , (dL ), (e)(1) and e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 3000 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 746 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIII. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B); ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(0): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(f) & (g) ® Yes ❑ No ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains horizontal 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item IX.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305W contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305(_ or (g), see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ❑ Yes [:]No ® N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the proj ect comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ❑ Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project require coverage/authorization under a 404 Nationwide or ❑ Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(cl(6) (additional permits/certifications)? ®Yes ❑ No Per 15A NCAC 02T.0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. [—]Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with 15A NCAC 02T, the Minimum Design Criteria for the Permitting of Pump Stations and Force Mains (latest version), and the Gravity Sewer Minimum Design Criteria (latest version) as applicable? To the best of my knowledge the existing ® Yes ❑ No private sewer meet these requirements. If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: 13 5 414U(m AY4 attest that this application for (Professional Engineer's name from Application Item III.1.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per vtk4,on. North Carolina Professional Engineer's seal, signature, and date: a SEAL • 35711 — �if S. KLPv \ q7o Applicant's Certification per 15A NCAC 02T .0106(b): I, �j h 3 wk '�"��� gd-^ attest that this application for Authority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 1.43-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. Signature: Date: 3" (L " 0 ZC> FORM: FTA 04-16 Page 5 of 5 RECEiVEMCDENR/DWR State of North Carolina RECEIVED/WCDE / Wa Department of Environmental Quality APRo8 z' z � 0920,0 Division of Water Resources WQROS Flow Tracking for Sewer Extension Applications MOORESVILLWQSWNAL OFFICE MOORESVILLE REGIONAL OFFICE (FTSE 10-18) Entity Requesting Allocation: Bloc Design Project Name for which flow is being requested: Atrium Providence FSED More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route of the proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: McAlpine Creek, Irwin Creek, Sugar Creek b. WWTP Facility Permit #: NCo024970, NC0024945, NCO024937 All flows are in MGD c. WWTP facility's permitted flow 99.0 d. Estimated obligated flow not yet tributary to the WWTP 11.95 e. WWTP facility's actual avg. flow 72.6 f. Total flow for this specific request 0.003 g. Total actual and obligated flows to the facility 84.5 h. Percent of permitted flow used 85.4 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the WWTP: (A) (B) (C) (D)=(B+C) (E)=(A-D) Design Obligated, Pump Pump Average Approx. Not Yet Total Current Station Station Firm Daily Flow** Current Tributary Flow Plus (Name or Permit Capacity, * (Firm / pi), Avg. Daily Daily Flow, Obligated Available Number) No. MGD MGD Flow, MGD MGD Flow Capacity*** Six Mile Creek 18 7.2 5.05 .251 5.3 1.896 * The Firm Capacity (design flow) of any pump station is defined as the maximum pumped now that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5, per Section 2.02(A)(4)(c) of the Minimum Design Criteria. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the WWTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): Unknown Downstream Permit Number: Unknown Page 1 of 6 FTSE 10-18 III. Certification Statement: I Keri Cantrell certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment addendums for which I am the responsible party. Signature of this form certifies that the receiving collection system or treatment works has adequate capacity to transport and treat the proposed new wastewater. Signing Official Signature Chief Engineer Title of Signing Official � ��► �.► Rom► \.. 3/30/2020 Date Page 2 of 6 FTSE 10-18 CHARLOTTE W4)TER July 8, 2019 Mr. David Klausman Bloc Design 2923 South Tryon Street Suite 320 Charlotte, NC 28202 SUBJECT: CAPACITY ASSURANCE REVIEW ATRIUM PROVIDENCE FSED 11516 PROVIDENCE ROAD, CHARLOTTE, NC CLTWATER TRACKING# 20193398 After analysis of the sanitary sewer associated with the proposed design of project 20193398, ATRIUM PROVIDENCE FSED, it was determined that there is sufficient capacity to accommodate the proposed sewer flow of 3,000 gallons per day (10 beds x 300 gpd/bed) at the connection point(s) indicated on the submitted utility plan for transmission to the McAlpine Creek Wastewater Treatment Plant; NPDES permit number NC0024970, for treatment. This acceptance of flow is based upon the existing capacity of the designated publicly owned treatments works. CLTWater agrees to furnish water to the subject project. The water quality to the subject project is regulated by the State Drinking Water Act Amendments of 1986, and The Water Supply Management Plan, PWS ID # 0160010, on file with the Public Water Supply Section of NCDEQ. However, CLTWater cannot guarantee a constant pressure or quality of flow. Due to the involvement of other agencies and continuing growth of the water and sewer system, the ability to provide service for future projects cannot be guaranteed nor reserved. Connection to the CLTWater and sewer system is accepted on a first come, first served basis. The applicant should understand that this letter is not authorization to construct private water or sewer systems, as the appropriate local or State permits are required prior to construction. If the appropriate authorization to construct permits are not obtained and construction has not started within two (2) years of issuance of this Capacity Assurance Review, and payment for any service connection() has not been received within two (2) years of issuance of this Capacity Assurance Review letter, this approval shall be rescinded and a new Capacity Assurance Review must be made. If you have any questions, you may contact me at (704) 432-5801. Sincerely, 4!vW,e rvwo- Arzo-La- Guillermo Anzola Engineering Assistant Charlotte Water 5100 Brookshire Blvd, Charlotte, NC 28216 charlottewater.org �A Operated by the City of Charlotte ouy- °gyp 3 � o z NyOi Ord �'y���+'�°l i o�� W 4 A p�P✓ram~ a ` 0 ? r1 •LAN a MEADOW RUN LN SFOA , l S(� r `IO-P DOro- a oop�. n yFQTy o R' D C h o V/ Q: --1 `D O ROUGf CD �. -n O m 0 2 a o� O a aO V r 15 , ba ��� �� 0. t1 o~Ol 'id 35Oy'13 ° 0 n a6l �yoRN DR r� C<c4cpF a o al, ' o �lFXgNOER'MA RT\�P �`!E� y �DARCY HOPKINS DR Qy3 S\? 4R CqN y °RrkFC °FZ c F F CORq C RO ~C4R"HURIDR �G y 01 ENO ROCK Rp r� tQ Oa OHS C -0 rInfD coz 1. O Q C < < o OLYMPIC CLUB DR CD Lq �.c S`�F o c < D > ((D UD cCUe DR I,d� �O r N Q 1? yVHEAt,p� p o m - l D ,6p °CF. D h n U) �o m �� !w"`'a✓7 t \ oA S MlLL RD - .r n C ---Fairway mvw Ila ._ Y cp r s Ik r. n � 1 r. :. a ry eiD , l 44 1 . aQ sa{ui� boo r m y. 11 T ji f 4 j� IIIlk I � , \ � �'� u.,�y ���•,,.r I @ r � 3/12/2020 North Carolina Secretary of State Search Results • Upload a PDF Filing • Order a Document Online • Add Entity to My Email Notification List • View Filings Professional Limited Liability Company Legal Name Beck Architecture, PLLC Home State Name Beck Architecture, LLC Information Sosld: 1028837 Status: Current -Active Date Formed: 2/20/2008 Citizenship: Foreign State of Incorporation: DE Annual Report Due Date: Currentgnnual Report Status: Registered Agent: CT Corporation System Addresses Reg Office Reg Mailing 160 Mine Lake Ct Ste 200 160 Mine Lake Ct Ste 200 Raleigh, NC 27615 Raleigh, NC 27615 Mailing 1807 Ross Avenue, Suite 500 Dallas, TX 75201 Principal Office c/o the Corporation Trust Company Corporation Trust Center 1209 Orange Street Wilmington, DE 19801 Professions Architectural services https://www.sosnc.gov/online_services/search/Business_Registration_ResuIts 1/1