Loading...
HomeMy WebLinkAboutWQ0013808_NOV-2018-PC-0085_20180321 'ENVIRONMENTAL-WATER SUPPLY-WASTEWATER-GEOTHERMAL CONNER CONSULTING, LLC 1284 WINDY RIDGE ROAD, CHAPEL HILL, NORTH CAROLINA 27517 PHONE: (919) 260-7301 FACSIMILE (919) 542-0453 March 21, 2018 Ms. Rebecca Chandler NC DEQ, Division of Water Resources Winston-Salem Regional Office 450 West Hanes Mill Road, Suite 300 Winston-Salem,North Carolina 27105-7407 Re: Notice of Violation(NOV-2018-PC-0085) Summerfield Renaissance Center Wastewater Disposal System Summerfield, Guilford County Permit#WQ0013808 Dear Ms. Chandler: On behalf of Kotis Properties, the following responses are warranted for the continued operation of the wastewater disposal system at Summerfield Renaissance Shopping Center which was deficient on several items. 1. A reminder letter usually goes out to the owner in regards to renewal but conversations with permitting indicated that the position had or has been vacant for several months. We have continued on under the old permit. 2. Upon further investigation with maintenance personnel, the leak in the area noted during the inspection was found and repaired. We have fixed the same problem in Zone 1 in three other places. Several sections of red hose making up the bend in the purple line runs were replaced with a better black rubber hose. The red hose was prone to leaking at the glue joint. Several leaks have been repaired on Zones 1 -3. 3. The inflow was 1278 gallons per day. I did not notice the numbers reported when I reviewed the report. They were actually the difference between weekly meter readings and not the difference in weekly meter readings divided by the number of elapsed days. I have revised the report and will resubmit. 4. The annual running average was skewed by a couple of months of high numbers. I cut off Zone 3 to get the numbers to come down. Zone 3 will be in compliance in May, 2018. -2 5. The freeboard violation was due to high rainfall in the spring of 2017. The discrepancy between freeboard in July was likely due to a misread of the gauge in the wet well. 6. The NC DOT has not finished. They have by some miracle been working on regrading the driveway down to the WWTP. As soon as we are satisfied that they are done with this regrade project; then we can reinstall a gate and tie the fence to the DOT fence (which is installed). 7. No one updated the notes for my certification. I paid late and had to send an extra$50. My wastewater certification was reactivated on February 2, 2018. 8. All trees have been removed and the fence is repaired around Zone 3. 9. 9a) We need another 30 days to properly assess the sand in the RSF(recirculating sand filter). 9b) The observation that Pump 1 was malfunctioning was new to all at the inspection. Immediate action was taken to correct the problem. It is likely that the cap was not tightened enough after the last cleaning (within two weeks) and it came off at some point. 9c) This statement is incorrect. The splitter box where the board was is between the wetlands and the RSF. This bypass is engineered into the system. 10. A staff gauge is present for the WWS(wet weather storage)pond. It is marked in quarter feet. Readings are taken with that mind. If necessary we can easily remove it and add more markings. 11. This request is unreasonable and impossible unless a weather station is directly tied into the computer. This system is capable of multiple dosings per day but limited to rain sensors and a complex "dose enabled" float system which involves zone irrigation and the WWS. Additional concern: 1. Within a week of the inspection, Stoner Electric out of Sanford was on site to troubleshoot the RSF panel. It was determined by the electrician that the panel was victim to a power surge. Several components were not working including a toggle switch for Pump 1, the high water float and electrical breaker. The RSF panel will now be equipped with a surge protector and new parts are on order. The RSF panel is functioning now. The partial malfunction was responsible for putting water in the splitter box with the board. 2. The willow tree will be removed on 3/27/18 or sooner. 3. The power to the WWS panel will remain on. I will cut power to the pumps as necessary leaving the power to the alarm on. Thank you for the opportunity to explain some of the situations and for catching my review oversight on the December 2017 report. Please call with questions and comments. Sincerely yours, a(ji 12Alet.j..... Chad Leinbach, ORC Cc: Dan Witcher, Kotis Properties Bradley Flynt—Backup Operator