Loading...
HomeMy WebLinkAboutSW5200201_Supplement-EZ Form_20200413SUPPLEMENT-EZ COVER PAGE jPROJECT INFORMATION 1 Project Name Lee Street Athletic Complex Improvements 2 !Project Area (ac) 14.068 3 Coastal Wetland Area (ac) 0 - _ _ -_ -_ _- - 4 Surface Water Area (ac) 0 =_R - 5 Is this project High or Low Density? Low 6 Does this project use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided (feet) _ N/A 8 l Will the vegetated setback remain vegetated? Yes 9 1 Is BUA other that as listed in .1003(4)(c-d) out of the setback? Yes b_; Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System_ _4__ 12 IBioretention Cell 13 Wet Pond 14 .JStormwater Wetland 15 Permeable Pavement 16 'Sand Filter 17 Rainwater Harvesting (RW_ H)____ 18 `Green Roof 19 Level Spreader -Filter Strip (LS-FS) 20 Disconnected Impervious Surface (DIS) 21 Treatment Swale 22 -_Dry Pond 23 �StormFilter 24 Silva Cell 25�!Ba- alter 26 { Filterra FORMS LOAr'F-D DESIGNER CERTIFICATIOP 27 TName and Title: 28 Organization: 29 !Street address: - 30 City, State, Zip: 31 Phone number(s): 32 Email: Zak Shipman, PE -President Shipman Engineering, PLLC 137 Middlegreen Place Holly Springs, NC 27540 (919) 900-0006 zak@shipmanengineering.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is; to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. Seal kA Signature of Designer 7 / &ZO Date DRAINAGE AREAS 1 Is this a high density project?--.. . No 2 If so, number of drainage areas/SCMs 1 Is all/part of this project subject to previous rule 3 versions? No DRAINAGE AREA INFORMATION Entire Site 4 1 Tye of SCM 5 Total BUA in project sq ft) _ 53789 sf 'New BUA on subdivided lots (subject to permitting) 6 (sq ft) New BUA outside of subdivided lots (subject to 7 permitting) (§J 15360 sf 8 Offsite - total area (sq ft) 9 ' Offsite BUA (sq ft) 10 Breakdown of new BUA outside subdivided lots: - Parking (sq ft) 10202 sf , - Sidewalk (sq ft) 3494 sf - Roof (sq ft) 1664 sf - Roadway (sq ft) - Future (sq ft) - Other, please specify in the comment box below (sq ft) New infiltrating permeable pavement on 11 subdivided lots (sq ft New infiltrating permeable pavement outside of 12 ubdivided lots (sq ft) JExisitngBUA that will remain (not subject to 13 'permitting) (sq ft) 38429 sf 14 Existing BUA that is already permitted (sq ft) 15 Existing BUA that will be removed (sq ft) 16 Percent BUA 9% 17 Design storm (inches) 18 Design volume of SCM (cu ft) 19 Calculation method for design volume ADDITIONAL INFORMATION Please use this space to provide any additional information about the 20 drainage area(s): LOW DENSITY n DESIGN REQUIREMENTS FOR LOW DENSITY PROJECTS FROM 02H .1003 1 Is project below density thresholds set forth in the applicable stormwater rule? Yes 2 Does project maximize dispersed flow and minimize channelization of flow? Yes 3 Has the use of piping been minimized per. 1 003(2)(c)? Yes 4 Side slopes of the vegetated conveyances (H:V) 3:1 5 Maximum velocity in the vegetated conveyances during the 10-year storm? 6 Are curb outlet swales proposed? No 7 Maximum longitudinal slope of curb outlet swale(s) (%) 8 Bottom width of curb outlet swale(s) (feet) 9 Maximum side slope of curb outlet swale(s) (H:V) 10 Minimum length of curb outlet swale(s) (feet) t 11 Are treatment swales used instead of curb outlet swales? k L-12 Is stormwater released at the edge of the setback as dispersed flow? No 13 Have stormwater outlets been designed to prevent downslope erosion? Yes 14 Are variations to rule .1003 proposed? No ADDITIONAL INFORMATION .nNow,. 15 Please use this space to provide any additional information about this low density project: µ No significant drainage conveyances are proposed. Drainage will be conveyed via sheet flow and several minor graded low spots into the existing drainage system. Swal 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30