HomeMy WebLinkAboutNCG140167_MONITORING INFO_20200113STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO.
G
DOC TYPE
❑ HISTORICAL FILE
[ MONITORING REPORTS
DOC DATE
❑ of �d b L 3
YYYYM M DD
c..
PROCESS WASTEWATER — Quarterly Discharge Monitoring Report
GENERAL PERMIT No. NCG140000
CERTIFICATE OF OVERAGE N0. NCG14 O I io 7
FACILITYNAME: ��oS mil-r�4 nM.I,:,K
PERSON COLLECTING SAMPLES: _--^`/ R�hhone
CERTIFIED LABORATORY: I�cseancho'f4t,#yly+!c-NOLab # 34
Lab it
LIMIT VIOLATIONS? YES O NO ®.
Part A' Wastewater Monitoring Requirements
SAMPLE COLLECTION YEAR: ?Dig i
SAMPLE QUARTER: O1ul-Sept [ZOct-Dec OJan-March DApril-June
COUNTY:
PHONE NO. (334) 'i c�5"
ADD TO LISTSERVE? OYES ONO EMAIL:
DISCHARGING TO CLASS: ❑SA OHQW ❑PNA OTrout DOther
OPTIONAL INFO:
Outfall No.
Date Sample
r
Collected
(mm/dd/yr)
Type of Wastewater
z
(VE, RM, MD)
pH
(standard)
total Suspended
Solids
Settleable
Solids
(mL/L)
TPH using
method I664A
SG! -HEM'
(mg/L)
Discharge
Duration
(minutes)
Total Flow
(gallons/day)
-
-
-
6-9 3,4
303,5
53
if r-u
XAN 1 1 >nv
' If wastewater systems have not discharged In this quarter— report "No Flow- or "No Discharge- here. Piease make sure io mark cne sample yuei ie, p vvc.
2 Report the abbreviation for the type of Authorized Wastewater Discharges here: Vehicle and Equipment Cleaning (VE), Raw Material Stockpiles (Rlvl), Mixing Drum
Cleanout (MD). Report more than one type if the waste -stream is commingled.
31f an effluent limit is exceeded twice in a row, the permittee is required to institute monthly monitoring for that parameter for six months, unless DWQ RD staff
notifies you to continue monitoring.
° PHlimitsare 6-9 S:U, for wastewater discharges to freshwaters, and 6.8-8.5 S.U. for discharges to saltwaters. . c
s TSS limits are 20 mg/L for wastewater discharges to HOW waters, 10 mg/L for Trout and PNA waters, and 30 mg/L for all other water classifications.,?1:
Permit Date: 7/1/2010-06/30/2015 - Last Revised 07/13/11
Page 1 of 2
s Process wastewater discharges shall only he monitored for TPH when commingled with stormwater discharges from VIVA areas. TPH does not have a'limit for wastewater,
but instead is subject to benchmarks and provisions of Part IV, Section A, including the Tiered Response Action.
' Flow rate can be measured continuously or calculated. Flow limits for wastewater discharges to HQW waters shall be set to 50% of the Summer 7QV0 Flow as per 15A
NCAC 02B .0224. Permittees who discharge wastewater to HQW waters shall obtain a Summer 7Q10.flow and report this information to DWQ. If tho'permittee cannot
obtain a Summer 7Q10 flow for the receiving waters at the discharge location, the permittee shall notify DWQ, and the DWQ Regional Office may require an annual flow
report on a case -by -case basis.
AT END OF MONITORING PERIOD IN CASE OF "NO FLOW") TO:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617 .
(919) 807-6379 -'
- i
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED.•
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the. person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and
complete. I am aware that there are significant penalties for submitting false Information, Including the possibility of fines and imprisonment for knowing
violations." ..
of Permittee)
Permit Date: 7/1/2020-06/30/2015
(Date)
Last Revised 07/13/11
Page 2 of 2
STORMWATER DISCHARGE OUTFALL (SDO) - Semi -Annual MONITORING FORM
GENERAL PERMIT NO. NCG140000 '
CERTIFICATE OF COVERAGE (NCO. NCG14 `a I
A FACILITY NAME: ti21S f(,e-r1 q
PERSON COLLECTING SAMPLES �a.rWZJk'i"�boar
CERTIFIED LABORATORY?,r-sci;;z�4�A11,4Je.1 Lab tt 34
OPTIONAL INFO:
Part A: Stormwater Monitoring Requirements
SAMPLE COLLECTION YEAR:' -
SAMPLING PERIOD: [July -December ❑January -June
COUNTY
PHONE NO. (33(-) i$S •`�,5--%1S
ADD TOLISTSERVE? [—]YES FIND EMAIL:
DISCHARGING TO CLASS: [—]SA ❑HQW ❑PNA ❑Trout ❑Other
Outfall Na.
Date Sample
Collected
(mo/dd/yr OR
NO FLOW)
PH
(Standard
Units)
TSS
(mg/L)
Event
Duration
(minutes)
Total
Rainfall'
(in)
)
In Tier 2
Monthly
Monitoring?
(y/n)
-
Al of Months in Tier
2 Sampling'
-
-
6-9Z
100113
n
7,L1
S(I
i If 'NO FLOW" or "NO DISCHARGE, Enter "NO FLOW" or "NO DISCHARGE" for each outfall here. Please make sure to mark the sample period above.
'If a value is In excess of the benchmark, or outside the benchmark range (for pH), you must implement the Tier 1 or Tier 2 responses in the General Permit.
Monthly sampling shall be done until 3 consecutive samples are below the benchmark or within the benchmark range.
' TSS benchmark values are 100 mg/I, except when discharging to ORW, HOW, Trout, and PNA waters where they are 50 mg/I.
° For each sampled measurable storm event the total precipitation must be recorded using data from an on -site rain gauge.
Permit Date: 7/1/2011-60/30/2015 Date of last pH meter calibration: 1a - /o-
Tier 2
Last Revised 7/13/11
Page 1 of 2
Part B: Vehicle Maintenance Activitv Monitoring
•-------
HAS YOUK FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES AT ANY ONE OUTFALL (INCLUDING VEHICLE MAINTENANCE)? YES ❑ NO
HAVE YOU CONTACTED THE REGION? YES Q NO
REGIONAL OFFICE CONTACT NAME:
in case of "No Flow") to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete.
am aware that there are significan p halties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
(Signature of Permrttee) ! (Date)
Permit Date: 7/1/2011-60/30/2015
. Last Revised 7/13/11
Page 2 of 2
RIESF-ARCh AN4y1'iCAQ Report of Analysis
LAbORMFORiES, MCa 12/16/2019
For: Ready Mixed Concrete Co (ARGOS)
4,
1491 Brookford Road
Kernersville, NC : :q NCN34
t NC 1137701
Attn: Danny Rathbone r, •.01,
Client Sample ID: 16239W
Lab Sample ID:
75799.01
Site: Ready Mixed
Concrete
Collection Date:
12/10/2019 13:00
Parameter
Method
Result
Units
Rep Limit Anal st Analysis Date/Time
pH
SM 4500 H+13-2000
7.4
Std. Units
12/10/2019 1300
Settleable Matter
SM 2540 F-1997
<0.1
mlll
0.1
AW 12/10/2019 1515
Total Suspended Solids (TSS)
SM 2540 D-1997
<5
mg/L
5
AW 12/12/2019
Client Sample ID: 16239S
Lab Sample ID:
75799412
Site: Ready Mixed
Concrete
Collection Date:
12/10/2019 13:00
Parameter
Method
Result
Units
Rep Limit Analyst Analysis DatelTime
pH
SM 4500 H+13-2000
7.4
Std. Units
12/10/2019 1300
Total Suspended Solids (TSS)
SM 2540 D-1997
5.6
mg/L
5
AW 12/12/2019
NA = not onolyzed
11
P.O. Box 473 106 Short Street Kernersville. North Carolina 27284 Tel: 336-996-2841 Fax 336-996-0326 v i.randalabs.com Page 1
[aI coo lresir. vta