Loading...
HomeMy WebLinkAboutNCG100027_MONITORING INFO_20191030jz o STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. c-G I DOD -7 DOC TYPE ❑ HISTORICAL FILE YMONITORING REPORTS DOC DATE ❑ u n U YYYYM M D D Mid Atlantic Engineering 9 Environmental Solutions October 10, 2019 Mr. Jesse Price Price's Auto Parts LLC 14473 NC 96 Highway Knightdale, NC 27597 RECE -`1 av2019 CEP4.1 7h'R SEC-r1OA/ Subject: STORMWATER SAMPLING RESULTS PRICE'S AUTO PARTS LLC 1900 OLD CREWS ROAD KNIGHTDALE, NORTH CAROLINA NPDES PERMIT NO. NCG100027 MID -ATLANTIC JOB NO. 000112900.00 Dear Mr. Price: 409 Rogers View Court Raleigh, NC 27610 office 919.250.9918 facilmile 919,250,9950 MAAONLINE.COM Attached please find three copies of the Stormwater Discharge Monitoring Report (DMR) for the above -referenced site. Please follow the instructions below to complete this sampling event. 1. If known, please fill in the rainfall total and pH for the sample collected August 27, 2019; 2. Sign and date each DMR on page 2; 3. Forward the first two copies of the report along with the attached cover letter to the Division of Water Quality (mailing address is on the first page of the DMR); and 4. Insert the third copy (labeled "FILE") into Appendix C of your Stormwater Pollution Prevention Plan. These results satisfy the analytical monitoring requirements for the second period (July - December) of 2019. The next sampling event can be conducted on or after January 1, 2020. Mid - Atlantic will arrange for cooler delivery prior to this date. If you have any questions, please contact me at 919-250-9918. Sincerely, MID -ATLANTIC ASSOCIATES, INC. Ron Davis Stormwater Services Manager Attachments: Cover Letters Stormwater Discharge Monitoring Reports Laboratory Analytical Reports EXPERIENCED CUSTOMER FOCUSED INNOVATIVE 109 aogen View court Mid Atlantic fficoRalaih.NC2761 olOce 919,750.4918 Engineering 8 Environmental Solutions facsimile 919$509950 MAAOM,INE.COM October 10, 2019 NCDEQ/DWR Attention: Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Subject: STORMWATER SAMPLING RESULTS PRICE'S AUTO PARTS LLC 1900 OLD CREWS ROAD KNIGHTDALE, NORTH CAROLINA NPDES PERMIT NO. NCG100027 To Whom It May Concern: Attached please find the Stormwater Discharge Monitoring Report (DMR) and analytical report for the sampling conducted at the above -referenced site. A stormwater sample was collected from Outfall 001 on August 27, 2019 and analyzed for total suspended solids (TSS), pH, total recoverable lead, oil and grease and ethylene glycol. As indicated on the attached DMR, all parameters were reported below or within their respective benchmark values. If you have any questions or need additional information, please contact me at 919-250-9918. Sincerely, MID -ATLANTIC ASSOCIATES, INC. Ron Davis Stormwater Services Manager Attachment: Discharge Outfall Monitoring Report Laboratory Analytical Report EXPERIENCED CUSTOMER FOCUSED INNOVATIVE STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT CERTIFICATE OF COVERAGE NO. NCG100027 FACILITY NAME Price's Auto Parts LLC PERSON COLLECTING SAMPLE(S) Jesse Price III CERTIFIED LABORATORY(S) Pace Analytical Lab #12 Lab # Part A: Stormwater Benchmarks and Monitoring Results SAMPLES COLLECTED DURING CALENDAR YEAR: 2019 COUNTY Wake PHONE NO. (919) 266-0171 PLEASE REMEMBER TO SIGN ON THE REVERSE 4 For sampling periods with no discharge, you must submit this discharge monitoring form noting "No Flow" or "No Discharge" within 30 days of the end of that period to comply with permit reporting requirements. Outfall No. Date Sample Collected, mo/dd/year Total Rainfall, inches 00400 00530 ---- 77023 01051 78141 pH, Standard Units Total Suspended Solids (TSS), mg/L Non -polar O&G/TPH (Method 1664 SGT-HEM), mg/L Ethylene Glycol, mg/L Lead, Total Recoverable, mg/L Total Toxic Organics3, mg/L Benchmark - - 6.0-9.01 100/502 15 8,000 (Tiers 2 and 3) 0.03 1.0 Outfall 001 08/27/19 3.5 < 5.0 < 5.0 <0.005 NA Note: If you report a sampled value in excess of the benchmark value, or outside the benchmark range for pH, you must implement Tier 1 or Tier 2 responses in the Generai Permit. iSee If pH values outside this range are recorded in sampled stormwater discharges, but ambient precipitation pH levels are lower, then the lower threshold of this benchmark range is the pH of the precipitation (within instrument accuracy)instead of 6 S.U. Readings from an on -site or local rain gauge (or local precipitation data) must be documented to demonstrate background concentrations were below the benchmark pH range of 6-9. 2See General Permit text to identify whether the more protective benchmark applies for especially sensitive receiving waters. 3For purposes of this permit the definition of Total Toxic Organics is that list as stated in Appendix D, Table II of Chapter 40 Code of Federal Regulations (CFR) Part 122. Form SWU-251, last revised October25, 2012 Page 1 of 2 STORMWATER DISCHARGE OUTFALL (SDO) MONITORING REPORT Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may request that DWQ waive monitoring of total toxic organics. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities allowed such a waiver, the discharger shall sign the following certification statement: Solvent Management Plan Certification Statement "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Name (Print name) Title (Print title) Signature Mail Original and one copy to: Division of Water Quality Attn: Central Files 1617 MailServiceCenter Raleigh, North Carolina27699-1617 Date "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge a nd belief, true, accurate, and complete. I am aware that there are jjgnificant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature oT'Permittee or Designee) `B /1 (Date) Form SWU-251, last revised October25, 2012 Page 2 of 2 aceAnalytical. www.pace/ebscom Pace Analytical services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 September 10, 2019 Chuck Hoffman Mid -Atlantic Associates, Inc 409 Rogers View Court Raleigh, NC 27610 RE: Project: Price's Auto Parts Pace Project No.: 92443443 Dear Chuck Hoffman: Enclosed are the analytical results for sample(s) received by the laboratory on August 29, 2019. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Tyriek Hooks tyriek.hooks@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Ron Davis, Mid Atlantic Associatees, Inc. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical services, LLC. Page 1 of 13 aceAnalytical. Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: Price's Auto Parts Pace Project No.: 92443443 Indiana Certification IDs 7726 Moller Road, Indianapolis, IN 46268 Illinois Certification #: 200074 Indiana Certification #: C-49-06 Kansas/NELAP Certification M E-10177 Kentucky UST Certification #: 80226 Kentucky W W Certification M 98019 Michigan Department of Environmental Quality, Laboratory #9050 Charlotte Certification IDs 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 Louisiana/NELAP Certification # LA170028 North Carolina Drinking Water Certification #: 37706 North Carolina Field Services Certification #: 5342 North Carolina Wastewater Certification #: 12 Asheville Certification IDs 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS Ohio VAP Certification #: CL0065 Oklahoma Certification #: 2018-101 Texas Certification #: T104704355 West Virginia Certification #: 330 Wisconsin Certification #: 999788130 USDA Soil Permit #: P330-16-00257 South Carolina Certification #: 99006001 Florida/NELAP Certification #: E87627 Kentucky UST Certification #: 84 Virginia/VELAP Certification #: 460221 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 VirginiaNELAP Certification #: 460222 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, L-C. Page 2 of 13 aceAnalytical e www.peceleba.can Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: Price's Auto Parts Pace Project No.: 92443443 Lab ID Sample ID 92443443001 Outfall No. 1 SAMPLE ANALYTE COUNT Method Analysts Analytes Reported Laboratory EPA 1664B JMS 1 PASI-C EPA 8015 Alcohol -Glycol CPH 1 PASI-I EPA 601 OD SH1 1 PASI-A SM 2540D-2011 CEH 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 3 of 13 mAnalytical ~.psalabs.cwn Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 ANALYTICAL RESULTS Project: Price's Auto Parts Pace Project No.: 92443443 Sample: Outfall No. 1 Lab ID: 92443443001 Collected: 08127119 07:30 Received: 08/29/19 10:10 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Qual 1664 SGT-HEM, TPH Analytical Method: EPA 1664E Total Petroleum Hydrocarbons ND mg/L 5.0 1 09/05/19 06:50 8015M Glycols in water Analytical Method: EPA 8015 Alcohol -Glycol Ethylene glycol ND mg/L 5.0 1 09/04/19 12:50 107-21-1 6010 MET ICP Analytical Method: EPA 6010D Preparation Method: EPA 3010A Lead ND ug/L 5.0 1 09/05/19 16:10 09/06/19 09:06 7439-92-1 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Total Suspended Solids 3.5 mg/L 2.5 1 08/31/19 03:19 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/10/2019 01:59 PM without the written consent of Pace Analytical Services, -LC. Page 4 of 13 JaceAnalytical" wmepacalabluc m Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Price's Auto Parts Pace Project No.: 92443443 QC Batch: 496063 Analysis Method: EPA 1664B QC Batch Method: EPA 1664E Analysis Description: 1664 SGT-HEM, TPH Associated Lab Samples: 92443443001 METHOD BLANK: 2672108 Matrix: Water Associated Lab Samples: 92443443001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Petroleum Hydrocarbons mg/L ND 4.8 09/05/19 06:46 LABORATORY CONTROL SAMPLE: 2672109 Spike LCS LCS % Rec Parameter Units Conic. Result e/ Rec Limits Qualifiers Total Petroleum Hydrocarbons mg/L 19.2 21.4 111 64-132 MATRIX SPIKE SAMPLE: 2672110 92443907002 Spike MS MS %Rec Parameter Units Result Conic. Result % Rec Limits Qualifiers Total Petroleum Hydrocarbons mg/L NO 19.2 19.8 98 64-132 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09110/2019 01:59 PM without the written consent of Pace Analytical Services, L-C. Page 5 of 13 aceAnalytical enw.pecitabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Price's Auto Parts Pace Project No.: 92443443 QC Batch: 519800 Analysis Method: EPA 8015 Alcohol -Glycol QC Batch Method: EPA 8015 Alcohol -Glycol Analysis Description: EPA 8015 Modified Associated Lab Samples: 92443443001 METHOD BLANK: 2397744 Matrix: Water Associated Lab Samples: 92443443001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Ethylene glycol mg/L ND 5.0 09/04/19 13:13 LABORATORY CONTROL SAMPLE: 2397745 Spike LCS 1-CS % Rec Parameter Units Conic. Result % Rec Limits Qualifiers Ethylene glycol mg/L 25 26.7 107 48-150 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2397746 2397747 MS MSD 92443443001 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result % Rec % Rec Limits RPD Qual Ethylene glycol mg/L ND 25 25 32.7 23.1 128 90 34-153 34 R1 Results presented on this page are in the units indicated by the wUnits' column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/10/2019 01:59 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 13 (AaceA www.nalytical to pewlebxcwn QUALITY CONTROL DATA Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: Price's Auto Parts Pace Project No.: 92443443 QC Batch: 496202 Analysis Method: EPA 6010D QC Batch Method: EPA 3010A Analysis Description: 6010 MET Associated Lab Samples: 92443443001 METHOD BLANK: 2672626 Associated Lab Samples: 92443443001 Parameter Units Lead ug/L LABORATORY CONTROL SAMPLE: 2672627 Parameter Units Lead ug/L Matrix: Water Blank Reporting Result Limit Analyzed Qualifiers ND 5.0 09/06/19 08:31 Spike LCS LCS % Rec Conc. Result % Rec Limits Qualifiers 500 500 100 80-120 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2672628 2672629 MS MSD 92443516002 Spike Spike MS MSD MS MSD % Rec Parameter Units Result Conc. Conc. Result Result e/ Rec % Rec Limits RPD Qual Lead ug/L NO 500 500 498 497 99 99 75-125 0 Results presented on this page are in the units Indicated by the'Units' column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/10/2019 01:59 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 13 aceAnalytical www.pacelabs.com Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA Project: Price's Auto Parts Pace Project No.: 92443443 OC Batch: 495521 Analysis Method: SM 254OD-2011 QC Batch Method: SM 25400-2011 Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 92443443001 METHOD BLANK: 2669750 Matrix: Water Associated Lab Samples: 92443443001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg/L NO 2.5 08/31/19 03:14 LABORATORY CONTROL SAMPLE: 2669751 Spike LCS LCS % Rae Parameter Units Cone. Result e/ Rae Limits Qualifiers Total Suspended Solids mg/L 250 248 99 90-110 SAMPLE DUPLICATE: 2669764 92443124001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 2240 4200 61 D6 SAMPLE DUPLICATE: 2669765 92443210001 Dup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 89.2 103 15 D6 Results presented on this page are In the units indicated by the 'Units' column except where an alternate unit is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09110/2019 01:59 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 13 ace Analytical. w Paceiabs cvm Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALIFIERS Project: Price's Auto Parts Pace Project No.: 92443443 DEFINITIONS DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. NO - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL -Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPAguidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES PASI-A Pace Analytical Services - Asheville PASI-C Pace Analytical Services - Charlotte PASI-I Pace Analytical Services - Indianapolis ANALYTE QUALIFIERS D6 The precision between the sample and sample duplicate exceeded laboratory control limits. Rt RPD value was outside control limits. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 09/10/2019 01:59 PM without the written consent of Pace Analytical Services, LLC. Page 9 of 13 aceAnalytical w xpacelab&vvvn Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Price's Auto Parts Pace Project No.: 92443443 Lab ID Sample ID QC Batch Method QC Batch 92443443001 Outfall No. 1 EPA 1664B 496063 92443443001 Outfall No.1 EPA8015AIcohol-Glycol 519800 92443443001 Outfall No.1 EPA3010A 496202 92443443001 Outfall No. 1 SM 2540D-2011 495521 Date: 09/10/2019 01:59 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Analytical Method EPA6010D Analytical Batch 496261 Page 10 of 13 aceAnalylical" Document Name: Sample Condition Upon Receipt(SCU11) Document Revised: February 7, 2018 Page 1 of 2 Document No.: F-CAR-CS-033-Rev.06 Issuing Authority: Pace Carolinas Quality Office Laboratory receiving samples: Asheville ❑ Eden[_ Client Name: ❑ Commercial Greenwood ❑ Custody Seal Present? ❑Yes ©No Seals Intact? ❑Yes i HuntersvilleI,I Raleigh[]Mechanicsville[]Mechanicsville Project k: ^®# : 92443443 1 Cli nt IIIII I III II II II III III 92443443 ONo Date/Initials Person Examining Contents:. Packing Material: ❑Bubble Wrap EgBubble Bags ❑None ❑ Other Biological Tissue Frozen? Thermometer: Type of ice: ❑Wet ❑Bue ❑None Dyes ❑No QN/A DiR bun to: 92T049 Cooler Temp ('c): 1 '?, .% Correction Factor: Add/Subtract ('C) 0.0 '-MP shos•Id bo ibova froaa ing to 6°6 Cooler Temp Corrected ('C): ❑Samples out of temp criteria, Samples on Ice, cooling process has begun USDA Regulated Soil (Q'N/A, water sample) Did samples originate in a quarantine zone within the United States: CA, NY, or SC (check maps)? Did samples originate from a foreign source (internationally, eyes MNo and PI-11 nve. nu„ Comments/Discrepancy: Chain of Custody Present? Ely/es ONO ❑N/A 1. Samples Arrived within Hold Time? 19Y i ❑No (-]N/A 2. Short Hold Time Analysis (02 hr.)? ❑Yes QNo ❑N/A 3. Rush Turn Around Time Requested? []yes ONO ❑N/A 4. Sufficient Volume? ❑Yes ONO ❑N/A 5. Correct Containers Used? ©Yes ONO ❑N/A 6. -Pace Containers Used? ❑`-yes ONO ❑N/A Containers Intact? ' Yes ONO ❑N/A 7. Dissolved analysis: Samples Field Filtered? Oyes No ©N/A S. Sample Labels Match CDC? []Yes ONO ❑N/q 9. I/J -Includes Date/Time/ID/Analysis Matrix; Heads ace in VOA Vials (>5-6mm)? ❑Yes ONO : N/A 10. Trip Blank Present? [-]yes ONO GN/A 11. Trip Blank Custody Seals Present? Yes ONO I]N /A DISCREPANCY Lot IDof split containers: CLIENT NOTIFICATION/RESOLUTION - Person contacted: Date/T'ime: Field Data Required? Oyes ONO j� s /— Project Manager SCURF Review: tYi 'i Date: 11vjj sII (7 Project Manager SRF Review: _ ryjlL Date: �J /^t� �G% . Page 11 of 13 Document Name: Document Revised: February 7, 2018 . BCBAl18jy(IC21 Sample Condition Upon Receipt(SCUR) Page 1 of 2 Document No.: Issuing Authority: F-CAR-CS-033-Rev.06 Pace Carolinas Quality Office 'Check mark top half of box if pH and/or dechlorination is Project k verified and within the acceptance range for preservation samples. Exceptions: VOA, Coliform, TOC, Oil and Grease, DRO/8015 (water) DOC, LLHg "Bottom half of box is to list number of bottle WO#:92443443 PM: TIH Due Date: 09/10/19 CLIENT: 92—MID RTLRN Q a ¢ _ u a n Z a U d a aa m Z v ZO0 ZUInJONEZO n aa n J E r a¢a a E a E a E v�i i a mo a O a O a O u n iina w `a n E c E >O 8 a ,n o = - d yO 0 '^ f E E O E O r c c of O E 0 E O 3 V O li la I:a li V V el U' O \ n 6 C to a a a a a a > > o > > � m > G 1 ]9 'ri h r 2 3 5 6 7 8 -1;7 \ 9 r\\\\ NNN--+-- N\ 10 ]1 12 pH Adjustment Log for Preserved Samples Sample ID Type of Preservative pH upon receipt Date preservation adjusted Time preservatlon adjusted Amount of Preservative added Lot a Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this farm will be sent to the North Carolina DEHNR Certification Office jl.e. Out of hold, incorrect preservative, out of temp, incorrect containers. Page 12 of 13 ace Analytical om+ss dart 1 CHAIN -OF -CUSTODY / Analytical Reques Document The Chain --Custody is a LEGAL DOCUMENT. Aa relevant fields must be co leted accurately. JaeNan A Section IS Section C Reputed Client Information Rethi ted P1.jW Information: 1. INomalion Page: of Company: Mid -Atlantic Associates, Inc. Rel+on To: Chuck Hoffman (choHman@maaonline.00m) Atenbon: ChuckHoffman Address: 409 Rogers View Court Copy To: Ron Davis (rdavis@maaonline.com Company Name; Mid -Atlantic Associates. Inc. ' REGULATORY AGENCY Raleigh, NC 27610 Address: 409 Rogers View Court, Raleig NC GRO f NPDES r GROUNDWATER DRINKING WATER Email To: choffman@maaonline.com Plumose Omer No: R2900.00 P Qaoa - Rer erce r LIST f- i OTHER Phone: 919-250-9918 Far 919-250-9950 Project Name: Prices Auto Parts Pace Purled 7ynek Hooks Man Jan Site LocaOo n . NC Requested e DateffAT: standard Du Project Number. R29D0.00 Ppx Pmlik f. 5921 . STATE: Rect Inted Analysis Filtered (YIN) Section D Valid Marta Codes -' Repuhed ckem hlm km NATAY GWE " o COLLECTED Preservalives i N Y N I Y OPHr94 Wk}ER W! wr " V z N watER U O .1E.M. PN COYia51iE 5reRi COYne51iF %iOIXlei $L SOk/SIXA CL s EMICJUB W es Z SAMPLE ID E o u Of Q 1A-2,0-91;) WKR Ts o Sample IDs MUST BE UNIOUE *IksuE O 1- th L_ (7 1e a O x ~ G a t DATE TIME DaTE TIME a SO S 2 Z Z O to w Of Pace Pro'ect Nal Lab I.D. t Outfall No. 1 wi G - A 7 a 1 2 x x x x Rainfall (inches): (7 2 Tss 1: 30 91.11 "T. 36 H: — d o H (OG4 a s 1:3L A" 1 4 +6 G co i I TP) a'i 113D 6 a 9 :30 6 T a 9 to 11 MDAM 12 ADDITIONAL COMMENTS REIJIWUISNED BY/AFDLWmON - ACCEPTEDEY I AFDWL N DATE }TIME SAMPLE CONDITIONS 12.7- Y IJ Y r SAMPLER NAMEANDSIGNATURE E m3- u iE PRINT Name of SAMPLER: N o9-1 w v E } SIGNATURE of SAMPLER: DATES ned O MMD ~ w y W O •mpert+m Rao-:er.¢ryr¢�nn rmm wu+..+mronrc vae'.Rn 3oe+r wrminnnma+rie nv�nt �o to- eti.tn el tsx rFr m 1mm ler+m m. F-ALL- 020rev.08. 12-Oct-2007 W