HomeMy WebLinkAboutNCG090007_MONITORING INFO_20191119ws�
STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO.
(V tL [� Cf o 00
DOC TYPE
❑ HISTORICAL FILE
C MONITORING REPORTS
DOC DATE
❑ (� I ' /
YYYYM M D D
Semi-annual Stormwater Discharge Monitoring Report
for North Carolina Division of Water Quality General Permit No. NCG090000
Date submitted 11/8/2019
CERTIFICATE OF COVERAGE NO. NCG09 O O O 7
FACILITY NAME Sherwin williams
COUNTY Guilford
PERSON COLLECTING SAMPLES Justin Sergent
LABORATORY RBA Labs Lab Cert. ft 34 V I\/F r,
Comments on sample collection or analysis: NOV 19 2019
-ENTRAL FILE:
DWR SECTION,
Part A: Stormwater Benchmarks and Monitoring Results
SAMPLE COLLECTION YEAR 2019
SAMPLE PERIOD ❑ Jan -June ❑■ July -Dec
or ❑ Monthly' (month)
DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
❑Zero -flow [:]WaterSupply USA
❑■ Other WS-y;NSW
PLEASE REMEMBER TO SIGN ON THE REVERSE 4
Total event rainfall' n No discharge this periodj2
Outfall No.
Date Sample Collected'
(mo/dd/yr)
Total Cadmium°,
mg/L
Chromium III, Total
Recoverable,
mg/L
Total Lead,
mg/L
pH,
Standard Units
Total Suspended Solids',
mg/L
Benchmarks
-
0.003 or 0.002
0.905
0.075
6.0-9.0
100 or 50
Parameter Code
-
01027
C0034
01051
00400
C0530
1
10/22/2019
<0.001
<0.005
<0.005
7.06
5.2
' Monthly sampling iinstead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
' For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
'See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Permit Date: 11/1/2018-05/31/2021 SWU-255, last revised 11/1/2012
Page 1 of 2
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month.
n No discharge this period ?2
Outfall No.
Date Sample
Collected'
(mo/dd/yr)
24-hour rainfall
amount,
IncheO
Non -polar Oil and
Grease,
mg/L
Total Suspended Solids'
mg/L
New Motor or
Hydraulic Oil
Usage,
gal/mo
Benchmarks
_
-
15
100 or 50'
Parameter Code
-
46529
00552
CO530
NCOIL
Footnotes from Part A also apply to this Part B
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑
IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑ NO ❑ .
REGIONAL OFFICE CONTACT NAME:
Mail an original coov of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the
case of "No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
J
of Permittee
Date
Permit Date: 11/1/2018-05/31/2021 SWU-255, last revised 11/1/2012
Page 2 of 2
THE SI-IERW IN WI LLIANIS CONIPANY
November 8, 2019
REC;E- 'VED
Central Files NOV 19 2019
Division of Watet Quality CENTRAL FILES
1617 Mail Service Center DWR uECT1QN
Raleigh, NC 27699-1617
Subject: Storm water monitoring and analysis
Dear Sir or Madam:
Please find enclosed one cop), of the semi-annual stormwatcr Qualitative monitoring
reports as well as the quantitative reports for samples taken during these observations.
I certify, under penalty of law, that this document and all attachments were prepared
under my direction or supervision in accordance with a system designed to assure that
qualified personnel properly gather and evaluate the information submitted. Based on my
inquiry of the person or persons who manage the system, or those persons directly
responsible for gathering the information, the information submitted is, to the best of my
knowledge and belief, true, accurate, and complete. I am aware that there are significant
penalties for submitting false information, including the possibility of fines and
imprisonment for knowing violations.
Best regards,
z�.
John Shagena
Plant Alanagcr
1025 I-IUAA'ARU STREFT • GREFNSBORU, NC • 27403
PI -TUNE: 336-299-9351
RESEARCU ANAIyTicA1
LAboRAT®RiES, INC.
For: Sherwin Williams Company - Howard
1025 Howard Street
Greensboro, NC 27403-2041
Attn: Justin Sergent
Report of Analysis
10/31/2019
ANk
el ►.Clio •A
4� p
¢ ; D NC #34 °y: •
s NC #37701
'+ s•.4ryE�pPr'
Client Sample ID: Outfall #1
Site: Sherwin Williams
Lab Sample ID:
Collection Date:
73890-01
10/22/2019 8:45
Parameter
Method
Result
Units
Rep Limit Analyst Analysis Date/Time
Cadmium, Total
EPA 200.7
<0.001
mg/L
0.001
JF 10/29/2019
Chromium, Total
EPA 200.7
<0.005
mg/L
0.005
JF 10/29/2019
Lead, Total
EPA 200.7
<0.005
mg/L
0.005
JF 10/2912019
pH
SM 4500 H+B-2000
7.06
Std. Units
AB 10/222019 1645
Total Suspended Solids (TSS)
SM 2540 D-1997
5.2
mg/L
5
AW 10/2312019
NA = not onolyzed
. _ Short
___.--..___. _ ... _. ..__ ___.___________._
P.O. Box 473 106 Short Street Kernersville, North Carolina 27284 Tel: 336-996-2841 Fax: 336-996-0326 vnvw.randalabs.com Page 1