Loading...
HomeMy WebLinkAboutNCG080961_MONITORING INFO_20200121/m" STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. ECG DOC TYPE ❑ HISTORICAL FILE MONITORING REPORTS DOC DATE ❑� �' / YYYYMMDD AV NV ATC —AN ATLASCOMPANY- December 20, 2019 Natalie Owens FedEx Ground Environmental Services 1000 FedEx Drive Moon Township, PA 15108 Subject: Stormwater Discharge Monitoring Report FedEx Concord Ground — ZCON 280 4350 Fortune Avenue NW Concord, North Carolina 28027 ATC Project No.: 199FED19C2 Dear Ms. Owens 7606 Whitehall Executive Center Drive, Suite 800 Charlotte. North Carolina 28273 Telephone 704-529-3200 Fax 704-529-3272 www.atcqroupservices.com RECF!\/FD JAN 21 2020 CEN I riNL FILES DWR SECTION ATC was contracted to perform a semi-annual stormwater monitoring event for the FedEx Concord Ground facility (ZCON 280) at 4350 Fortune Avenue NW in Concord, North Carolina. The stormwater sampling event included the collection of a stormwater sample and outfall observations for qualitative parameters during a measurable storm event. The monitoring was conducted in general conformance with the requirements of the Slate of North Carolina Department of Environmental Quality (NCDEQ), National Pollutant Discharge Elimination System (NPDES), General Permit NC800000, which is effective from November 1, 2018 to May 31, 2021. On November 24, 2019, a stormwater sample was collected at the designated discharge point, Outfall #1 (OF-1), the outfall from a stormwater retention pond for surface runoff from the facility, based on a storm event that met the requirements for monitoring. Figure 1 is provided depicting the stormwater sampling location. The collected sample was submitted to North Carolina -accredited Prism Laboratories, Inc. in Charlotte, North Carolina, for analysis of total suspended solids (TSS) by EPA Method SM2540D-11, Non -Polar Oil and Grease (O&G)/Total Petroleum Hydrocarbons by EPA Method 1664A (SGT-HEM), and pH by field analysis. A total rainfall amount reading was collected from a nearby gauging location. Results of visual observations, qualitative parameters, and the total rainfall readings are provided in the attached Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report and Semi -Annual SDO Monitoring Report. Based on the specified monitoring parameters, as outlined in Part II, Section C of the NPDES for North Carolina General Permit NC800000 or Certificate of Coverage No. NCG080961, the laboratory results of the O&G of <5.0 mg/L (milligrams/liter) did not exceed the discharge benchmark of 15 mg/L. The laboratory results of the TSS of 4.3 mg/L did not exceed the discharge benchmark of 100 mg/L. The pH result of 7.51 (field reading) is within the range of the discharge benchmark values. Please note that the SDO Monitoring Report requires certification by signature of permittee (FedEx employee) before submittal of the entire report to the address on page one of the SDO Monitoring Report. Please sign on Page 2 of 2 of the SWU-250 SDO form and then send to the DWQ. Please provide a copy of the signed Semi - Annual SDO Monitoring Report to ATC. If you have any questions, please contact us at 704-529-3200. Sincerely, Diana Lanier Project Manager ATC Email: diana.lanier(d)a atcgs.com Attachments: Figure 1 — Stormwater Sample Location Map SDO Qualitative Monitoring Report Semi -Annual SDO Monitoring Report A" - ® 0 `_ Elliot J. Nightingale, P.G. Senior Consultant ATC Email: elliot.nightingale(a)atcgs.com Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit https:Hdeu.nc.gov/about/divisions/enerev-mineral-land- resources/enerev-mi nera I -I and -peen it s/stormwater-perm it s/npdes-i nd ust ri al-sw#tab-4 Permit No.: N/C/ 8 / 0 / 0 / 0 / 0 / 0 or Certificate of Coverage No.: N/C/G/ 0 / 8 / 0 / 9 / 6 / 1 Facility Name: FedEx Ground Concord (ZCON 280) County: Cabarrus Phone No. _I-800-863-3339 Inspector: Diana Lanier with ATC Group Services LLC (For stormwater discharge sampling only) Date of Inspection: 11-24-2019 Time of Inspection: 1 1:00 -Total Event Precipitation (inches): 0.99 JAN 21 2020 CEN'I WL t-ILES DWR SECTION All permits require qualitative monitoring to be performed during a "measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the permittee is able to document that a shorter interval is representative for local storm events during the sampling period, and the permittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: Q� with ATC Group Services LLC for FedEx Ground (Signature of Petmittee or Designee) Outfall Description: Outfall No. _I Structure (pipe, ditch, etc.): One pipe drain to an intermittent stream Receiving Stream: Intermittent tributary of Afton Creek Describe the industrial activities that occur within the outfall drainage area: No industrial activities are performed at the outfall area. A stormwater retention pond is located adjacent to the southeast of Outfall No. I. The Fedex facility is located further northeast. Page I of 2 SWU-242, last modified 07/28/2017 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Clear, slight light green tint 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, ctc.): None 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 ❑2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 2 ❑3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: ❑2 3 4 5 7. Is there any foam in the stormwater discharge? o Yes 8. Is there an oil sheen in the stormwater discharge'? OYes No No 9. Is there evidence of erosion or deposition at the outfall? O Yes O No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Generally clear, with slight green tint. Fallen leaves present on surface. Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 07/28/2017 Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCGO80000 Date submitted December 20, 2019 CERTIFICATE OF COVERAGE NO. NCG08 0 9 6 1 FACILITY NAME FedEx Ground (ZCON 280) COUNTY Cabarrus PERSON COLLECTING SAMPLES Diana Lanier with ATC RFCF I v ED LABORATORY Pace Analytical Lab Lab Cent. N 12 �1 Z�ZO Comments on sample collection or analysis: a L FILES vQWR SECTION SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD Q Jan -June ❑ July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply [:]SA QOther PLEASE REMEMBER TO SIGN ON THE REVERSE 4 Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new oil per month? ❑ yes ■❑ no (if ves, complete Part A) Part A: Vehicle & Equipment Maintenance Areas Monitoring Requirements (If applicable) ❑ No discharge this period2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Non -Polar Oil & Grease mg/L Total Suspended Solids, mg/L New Motor or Hydraulic Oil Usage, gal/mon Benchmarks - - 15 100 or 504 Parameter Code - 46529 00552 C0530 NCOIL ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outtall. ' For sampling periods with no discharge at any single outtall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. 4 See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Note: Results must be reported in numerical format. For example, do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non - numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Conversely, where fecal coliform results exceed the dilution upper limit, report the result as ">XX". Permit Date: 11/1/2018-5/31/2021 SWU-248, last revised 11/1/2018 Page 1 of 2 Part B: Oil/water Separators and Secondary Containment Areas at Petroleum Bulk Stations and Terminals (if applicable) ❑ No discharge this periodz Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches' Sample Collected' mo/dd/yr Total Suspended Solids, mg/L pH, Standard units Non -Polar Oil & Grease, mg/L Permit Limit - - - 100 or 504 6.0 — 9.0 15 Parameter Code - 46529 - COS30 00400 00552 Outfall #1 November 24, 2019 0.99 November 24, 2019 4.3 7.51 < 5.0 Footnotes from Part A also apply to this Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 1, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DEMUR REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original copv of this DMR, including all "No Discharge" reports within 30 days of receipt of the lob results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that theje are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." 7 Permit Date: 11/1/2018-5/31/2021 ANTHONYSPALVIERI Assistant Secretary SWU-248, last revised 11/1/2018 Page 2 of 2 aceAnalytical p rw.pacdlluixers December 05, 2019 Ms. Diana Lanier ATC Group Services LLC 7606 Whitehall Executive Cente Suite 800 Charlotte, NC 28273 RE: Project: FEDEX-ZCON 280 Pace Project No.: 92455285 Dear Ms. Lanier: Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Enclosed are the analytical results for sample(s) received by the laboratory on November 26, 2019. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, 7� / Taylor Ezell taylor.ezell@pacelabs.com (704)875-9092 Project Manager Enclosures cc: Elliot Nightingale, ATC Associates &1takV90" REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the voitten consent of Pace Analytical Services, LLC. Page 1 of 11 aceAnalytical e .pacelmhs.wm CERTIFICATIONS Project: FEDEX-ZCON 280 Pace Project No.: 92455285 Pace Analytical Services Charlotte 9800 Kincey Ave. Ste 100, Huntersville, NC 28078 South Carolina Certification #: 99006001 Louisiana/NELAP Certification # LA170028 Florida/NELAP Certification #: E87627 North Carolina Drinking Water Certification #: 37706 Kentucky UST Certification #: 84 North Carolina Field Services Certification #: 5342 Virginia/VELAP Certification #: 460221 North Carolina Wastewater Certification #: 12 Pace Analytical Services Asheville Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 2225 Riverside Drive, Asheville, NC 28804 North Carolina Wastewater Certification #: 40 Florida/NELAP Certification #: E87648 South Carolina Certification #: 99030001 Massachusetts Certification #: M-NC030 VirginiaNELAP Certification #: 460222 North Carolina Drinking Water Certification #: 37712 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 2 of 11 (�55?eAnalyfical' t nr.pacelaha.tam SAMPLE ANALYTE COUNT Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: Pace Project No.: FEDEX-ZCON 280 92455285 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92455285001 Outfall #1 EPA 1664E HH 1 PASI-C SM 2540D-2011 MJP 1 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, -LC. Page 3 of 11 aceAnalytical m rw.pacelabs.com ANALYTICAL RESULTS Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Project: FEDEX-ZCON 280 Pace Project No.: 92455285 Sample: Outfall #1 Lab ID: 92455285001 Collected: 11/24/19 11:00 Received: 11/26/19 12:00 Matrix: Water Parameters Results Units Report Limit DF Prepared Analyzed CAS No. Oual 1664 SGT-HEM, TPH Analytical Method: EPA 1664E Total Petroleum Hydrocarbons ND mg/L 5.0 1 12/05/19 11:30 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Total Suspended Solids 4.3 mg/L 2.6 1 11/27/19 12:24 Date: 12/05/2019 0453 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, -LC. Page 4 of 11 aceAnalytical rrrr.pacdaba.cem Project: FEDEX-ZCON 280 Pace Project No.: 92455285 QC Batch: 513041 QC Batch Method: EPA 1664B Associated Lab Samples: 92455285001 LABORATORY CONTROL SAMPLE: 2750314 Parameter Units Total Petroleum Hydrocarbons mglL QUALITY CONTROL DATA Analysis Method: EPA 1664B Analysis Description: 1664 SGT-HEM, TPH Spike LCS LCS e/ Rec Conic. Result e/ Rec Limits 20 15.3 76 64-132 Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 Qualifiers MATRIX SPIKE SAMPLE: 2750315 92455285001 Spike MS MS % Rec Parameter Units Result Conc. Result e/ Rec Limits Qualifiers Total Petroleum Hydrocarbons mi NO 20 NO 12 64-132 Results presented on this page are in the units indicated by the "Units" column except where an alternate unit Is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Dale: 12/05/2019 04:53 PM without the written consent of Pace Analytical Services, L-C. Page 5 of 11 aceAnalytical e rrr,pecaleAs.com QUALITY CONTROL DATA Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)a75-9092 Project: FEDEX-ZCON 280 Pace Project No.: 92455285 OC Batch: 512118 Analysis Method: SM 254OD-2011 QC Batch Method: SM 254OD-2011 Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 92455285001 METHOD BLANK: 2746362 Matrix: Water Associated Lab Samples: 92455285001 Blank Reporting Parameter Units Result Limit Analyzed Qualifiers Total Suspended Solids mg/L NO 2.5 11/27/19 12:22 LABORATORY CONTROL SAMPLE: 2746363 Spike LCS LCS % Rec Parameter Units Cone. Result % Rec Limits Qualifiers Total Suspended Solids mg/L 250 248 99 90-110 SAMPLE DUPLICATE: 2746364 92455018001 Cup Parameter Units Result Result RPD Qualifiers Total Suspended Solids mg/L 142 152 7 Results presented on this page are in the units Indicated by the "Units" column except where an alternate unit Is presented to the right or the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 12/05/2019 04:53 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 11 0 ace Analytical rw.panlabf.com QUALIFIERS Project: FEDEX-ZCON 280 Pace Project No.: 92455285 DEFINITIONS Pace Analytical Services, LLC 9800 Kincey Ave. Suite 100 Huntersville, NC 28078 (704)875-9092 OF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MOIL - Adjusted Method Detection Limit. POL - Practical Ouantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI -The NELAC Institute. LABORATORIES PASI-A Pace Analytical Services - Asheville PASI-C Pace Analytical Services - Charlotte REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Dale: 12/05/2019 04:53 PM without the written consent of Pace Analytical Services, LLC. Page 7 of 11 laceAnalyfical' r .pecdalplxcm QUALITY CONTROL DATA CROSS REFERENCE TABLE ProjecT. FEDEX-ZCON 280 Pace Project No.: 92455285 Lab ID Sample ID QC Batch Method QC Batch 92455285001 92455285001 Outfall #1 Outfall #1 EPA 1664E SM 2540D-2011 513041 512118 REPORT OF LABORATORY ANALYSIS Pace Analytical Services, LLC 9800 Kincey Ave. Suite 1DO Huntersv,lle, NC 28078 (704)875-9092 Analytical Method Analytical Batch This report shall not be reproduced, except in full, Dale: 12/05/2019 04:53 PM without the written consent of Pace Analytical Services, LLC. Page 8 of 11 Document Name: Document Devised: February 1, 2018 aceAnaVicalo Semple Condition Upon Recel t(SCUR) Page 1 of 2 Document No.: Issuing Authority: ( F-CAR•CS-033-Rev.06 Pace Carolinas Quality Office Laboratory receiving samples: Asheville ❑ Eden❑ Greenwood ❑ Huntersville Raleigh❑ MechanicsvilleM • �# 10# : 92455285 nClienntt Name: ` {+ I L wDy/1 3eNiGes Protect a: 111 ❑�— , Courier: Fed Ex ❑LISPS ❑Client HIM 111111111111 ❑ Commercial —[]Other:_ 92455285 'Place Custody Seal Present? ❑Yes "[DNtf Seals Intact? ❑Yes Data/ Initials Person Examining [gnlanis:& a46'// f Packing Material; []Bubble Wrap Bubble Bags ❑None ❑ Other Blolaglcal TissueF zen? Thermometil Type of ice: et ❑glue ❑None ❑YeS ❑NoN/A /EIIP Gun ID: _ 92T058 Coder Temp ('C): a ' S Correction Factor: Add/Subtract IT) 0.00C S Temp should be above freezing to 6'C Cooler Temp Corrected IT): '� ❑Samples out of temp criteria. Samples on ice, cooling process USDA Regulated Soil N/A, water samplel hasbegun Did samples originate a quarantine zone within the United States: CA, NY, or SC (check maps)? Old samples originate from a foreign source (internationally, 1-1v.. I'lu. Inrindlne Hawaii and Pupnn Rico)? MYes FIN. Comments/Dlscre anc : Chain of Custody Present? n No N/A 1. Samples Arrived within Hold Time? M41 No N/A 2. Short Hold Time Analysis 1<72 hr.)?--- - yes ja L. NA 3. --" -"- ----"—"—'—"-"'---— — -�— RushTomArotlndTlmeRequested? Dyes No ❑N/A 4. Sufficient Volume? fi�-sv�es ONO _• N/A 5. _ Correct Containers Used? -Pace Containers Used? "s' ONO OGs ONO ❑N/A N A 6. Containers Intact? Z< ONO N/A 7. Dissolved analysis: Samples Field Flltered? Dyes Zfr. ❑N/A 8. - Sample labels Match Ct7CI -Includes Date/Time/10/Analysis Matrix: Yes ONO -]N/A 9. Heads ace in VOA Vials (>5-6mm)7 DYes No EINTA 10. Trip Blank Present? Trip Blank Custody Seals Present? Dyes ONO MY11 ONO /A /A 11. COMMENTS/SAMPLE DISCREPANCY Lot 10 of split containers: CLIENT NOTIFICATION/RESOLUTION Person contacted: Project Manager SCURF Review: Project Manager SRF Review: Date/Time: Field pata Required? Dyes ❑No Date: f� 2% 17 Date: /Z Page 9 of 11 Document Name: Document Revised: February 7, 2018 aceAnafytical� Sample Condition U on Recel t SCUR Page 1 of 2 Document No.: Issuing Authority: ( F-CAR-CS-033-Rev.06 Pace Carolinas Quality Office *Check mark top half of box If pH and/or dechlorination is verified and within the acceptance range for preservation samples. Exceptlons: VOA, Coliform, TOC, Oil and Grease, DRO/801S (water) DOC, LLHg "Bottom half of box Is to list number of bottle Project# W0# : 92455285 PM: PTE Due Date: 12/05/19 CLIENT: 92-ATC 8i d E o J a E it J u E Ln .. n S i E O M E r�l. a E O Z u E to a v n j E 2 E 7 = a of i r� E a u m :.j x E a E z E a i i > E O of a O E a S E O ) E 1 rL > x a N E i G E zry - — n E J a E n° rh E E E t 2 4 6 6 7 a 9 10 11 12 pH Adjustment Log for Preserved Samples Sample ID Type of Preservative pH upon receipt Dote pres+rvadon adjusted Time preservation adjusted Amount of Preservative added Lot Note: Whenever there is a discrepancy affecting North Catalina compliance samples,a copy of this form will be tent to the North Carolina DEHNR Certification Office(Lo. Out of hold, incorrect preservative, out of temp, incorrect containers. Page 10 of 11 102kWa. CHAIN -OF -CUSTODY / Analytical Request Document o The Chain -of -Custody is a LEGAL DOCUMENT. All relevant fields must he completed accurately. iJf�✓ _ - F1. N section A sold. B ' ` n -L-UN LCi\ I Beaten C a Requmed Client wermat)on: Requi2E Project Information: I Invoice lnformalion: Page: I 1 Of 1 Company: ATC Group Services LLC-Cerbtte lReloon To: Diem Lanior I lAftem., SC4'nG Aetre. 76M Mdehall Eeeaaive Came Copy To: I Company Name M: Coda. NC 28273 i AGErass: - . R " Wat - Emil diana Ianieri®atcgs.Cam Purcrvoo Order e: ;. Pace Orae: I Ptane: 7oa)s2'.13 w IF. Project Name: FedEz GrourM East �I Pace Prgea Manager: t Iorezell ,welabs win - State f Location _. Requested Due Date: }R, ,_ 1 ���; F\TC_ Pmpct K I--,[ 1=F0 iIZ. 1 Pace Pra . N. m—r s INC --Requested AeW. Fillrod vwteu com 8 COLLECTED Preservatives > pnYmq Wuer OW 'e V 0' SAMPLE ID oL o START END Fm '" `' s one cnamaer ar eo,. sample lea must ea unique Q W �s TIATITWE Tl.�TWE O 2 m 0 0 n `m Q N �� .? S i i i f C S Co r c S SZ 2 , t 3 a 6`- I 6', I 7 ' 8 9 10 11 12 -.. ADg7gNALCOYYFNiS -R ^eucn fiY IAFFIWTION BATE ACCEPIEDBY r AFFIWTON. - DATE TYE ISAYPLE CONg1i1gN9 SAMPLER NAPE AND SIGNATURE ..-� - - -. U s .. PRINT Name of SAMPLER: a c i e ors ' 2 z E m 'u i SIGNATLFZ1E- N LER ed DATE Sign: '/�- 7-Z`t'19