Loading...
HomeMy WebLinkAboutNCG080019_MONITORING INFO_20200115STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. c- G O� d 0 DOC TYPE ❑ HISTORICAL FILE EY MONITORING REPORTS DOC DATE ❑ �dt YYYYMMDD M13=®5 ENVIRONMENTAL January 8, 2020 Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 RE: STORMWATER DISCHARGE MONITORING REPORT Old Dominion Freight Line, Inc. Charlotte, North Carolina Facility 3330 Stafford Drive Charlotte, North Carolina 28202 Certificate of Coverage NCG080019 Dear Stormwater Coordinator: RECEIVED JAN 15 2020 CENTRAL FILES DWR SECTION On behalf of Old Dominion Freight Line, Inc., the attached Stormwater Discharge Monitoring Report (DMR) is being submitted by GEOS Environmental, Inc. (GEOS) for the above -referenced site. One original and one copy are attached. The laboratory analytical report with chain -of -custody documentation is also attached. The stormwater sampling results show both Total Suspended Solids (TSS) and Oil & Grease (0&G) exceeded the respective benchmark concentrations. ATier 1 inspection is being performed to assess what may have caused the exceedances and identify and implement corrective actions. If you have any questions regarding this submittal, please do not hesitate to call me at (813) 601-4206 or contact me at tcook(algeosewnvironmental.com. Sincerely,,._-._ �Tho�� P G./ Sr-.P-roject Manager cc: Joseph Fuhr, Old Dominion Freight Line, Inc. Attachments GEOS Environmental, Inc. 13014 N. Dale Mabry Ilwy, No. 117 Tampa, FL 33618 ww%v.geosenvironmentaLcom Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No, NCGO80000 Date submitted December 22, 2017 CERTIFICATE OF COVERAGE NO. NCG080019 FACILITY NAME Old Dominion Freight tine, Inc. COUNTY Mecklenburg PERSON COLLECTING SAMPLES Jeremy Miller LABORATORY: Shealey Environmental Services, Inc. Lab Cert. # 329 Comments on sample collection or analysis: Part A: Vehicle Maintenance Areas Monitoring Requirements SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June M July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA RFrFl1/Fp ❑Zero -flow ®Water Supply ❑SA ❑Other JAN 15 2020 EN ORAL FILES DWR SECTION PLEASE REMEMBER TO SIGN ON THE REVERSE 4 ❑ No discharge this period' Outfall No. Date Sample Collected, mo/dd/yr 00530 00400 00556 Total Suspended Solids, mg/L pH, Standard units Non -Polar Oil and Grease/TPH EPA Method 1664 (SGT-HEM), mg/L New Motor Oil Usage, Annual average gal/mo Benchmark 50 or 100 see permit Within 6.0 —9.0 15 - 001 12/10/19 320 7.1 38 Part B: Oil/water Separators and Secondary Containment Areas at Petroleum Bulk Stations and Terminals Outfall No. Date Sample Collected, mo/dd/yr 00556 00530 00400 Non -Polar Oil and Grease/TPH EPA Method 1664 (SGT-HEM), mg/L Total Suspended Solids, mg/L pH, Standard units Permit Limit 15 50 or 100 see permit 6.0 — 9.0 1 For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. SWU-250 last revised October 25. 2012 Pave I of 2 STORM EVENT CHARACTERISTICS: Date 12 30 19 (first event sampled) Total Event Precipitation (inches): 0_6 Date (list each additional event sampled this reporting period, and rainfall amount) Total Event Precipitation (inches): Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ - REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR including all "No Discharge" reports within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." yy,� —'Vvk of Permittee) 1/13/2020 (Date) Additional copies of this form may be downloaded at: http://portal.ncdenr.org/web/wq/ws/su/npdessw#tab-4 S%VU-250 last revised October 25. 2012 Pa_e 2 of 2 SHEALY ENVIRONMENTAL SERVICES, INC. Report of Analysis Schnabel Engineering, LLC 104 Corporate Blvd. Suite 420 West Columbia, SC 29169 Attention: David Ebinger Project Name: Old Dominion Lot Number:UL11095 Date Completed:12/24/2019 12/24/2019 5:50 PM Approved and released by: Project Manager: Cathy S. Dover P<_G•1Fp J�1rj 4N1 Y, I'Y V'W The electronic signature above is the equivalent of a handwritten signature. This report shall not be reproduced, except in its entirety, without the written approval of Shealy Environmental Services, Inc. Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 79 1-9 111 w .shealylab.com Paec I ul Id SHEALY ENVIRONMENTAL SERVICES, INC. SC DHEC No: 32010001 NELAC No: E87653 NC DENR No: 329 NC Field Parameters No: 5639 Case Narrative Schnabel Engineering, LLC Lot Number: UL11095 This Report of Analysis contains the analytical result(s) for the sample(s) listed on the Sample Summary following this Case Narrative. The sample receiving date is documented in the header information associated with each sample. All results listed in this report relate only to the samples that are contained within this report. Sample receipt, sample analysis, and data review have been performed in accordance with the most current approved NELAC standards, the Shealy Environmental Services, Inc. ("Shealy") Quality Assurance Management Plan (CAMP), standard operating procedures (SOPS), and Shealy policies. Any exceptions to the NELAC standards, the CAMP, SOPS or policies are qualified on the results page or discussed below. If you have any questions regarding this report please contact the Shealy Project Manager listed on the cover page. Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 w .shealylaocom Page 2 o l 14 SHEALY ENVIRONMENTAL SERVICES, INC. Sample Summary Schnabel Engineering, LLC Lot Number: UL11095 Project Name: Old Dominion Project Number: Sample Number Sample ID Matrix Dale Sampled Date Received 001 SDO-001 Aqueous 12/10120191601 12/11/2019 (1 sample) Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealylab. com Pugc= of 14 SHEALY ENVIRONMENTAL SERVICES, INC. Detection Summary Schnabel Engineering, LLC Lot Number: UL11095 Project Name: Old Dominion Project Number: Sample Sample ID Matrix Parameter Method Result Q Units Page 001 SDO-001 Aqueous TSS SM 2540D- 320 mg/L 5 001 SDO-001 Aqueous HEM (oil and grease) 1664B 38 mg/L 5 (2 detections) Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealylab,com Page 4 of 14 Inorganic non-metals Client: Schnabel Engineering, LLC Laboratory ID: UL11095-001 Description: SDO-001 Matrix: Aqueous Date Sampled: 12110120191601 Project Name: Old Dominion Date Received: 1211112019 Project Number: Run Prep Method Analytical Method Dilution Analysis Date Analyst Prep Date Batch 1 (TSS) SM 254OD-2011 1 12/15/2019 2013 MOM 39063 1 (HEM (oil and) 16646 1 12/24/2019 0000 CRD 39973 CAS Analytical Parameter Number Method Result Q LOQ DL Units Run TSS SM 2540D- 320 25 1.0 mg/L 1 HEM (oil and grease) 1664B 38 5.0 1.5 mglL 1 LOO = Limit of Ouantuation 6 = Detected in the method blank E = Ouantitation of compound exceeded the calibration range OIL = Detected Limit NO = Not detected at or above the DL N = Recovery is out of criteria P e The RED between two GC colunms exceeds 40 % J = Estimated result < LOO and? DL H = Out of holding time W = Reported on wet weight basis Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791 -91 11 www, shealylab. com Page i of 14 QC Summary Shealy Environmental Services, Inc. CC Data for Lot Number: UL11095 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.sheatylab. corn Pace 6 of W Inorganic non-metals - MB Sample ID: UQ39063-001 Matrix: Aqueous Batch:39063 Analytical Method: SM 254OD-2011 Parameter Result Q Dil LOQ DL Units Analysis Date TSS ND 1 1.0 1.0 1 12/15/2019 2013 LOD = Limit of Ouamltation P = The RPD between two GC columns exceeds 40% N = Recovery is out of criteria DL = Defection Lind J = Estimated result < LOD and > DL = ROD is out of criteria LOD = Limit of Detection ND = Not detected at or atmve the DL Note: Calculations are performed before rounding to avoid round -off errors in calculated results Shealy Environmental Services, Inc. QC Data for Lot Number: UL11095 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealylab.com Ptrac 7 of 14 Inorganic non-metals - LCS Sample ID: UQ39063-002 Matrix: Aqueous Batch: 39063 Analytical Method: SM 254OD-2011 Spike Amount Result % Rec Parameter (ni (mg/L) Q Dil % Rao Limit Analysis Date TSS 250 250 1 98 90-110 12/15/2019 2013 LOD = Limit of Ouantvaoon P = The RPD between two GC columns exceeds 40h N = Recovery is out of criteria Of. = Detecuon Limit J = Estimated result < LOD and > DL = RPD Is out of criteria LOD = Limit of Detection NO = Not detected at or above the DL Note: Calculations are performed before rounding to avoid round -off errors in calculated results Shealy Environmental Services, Inc. QC Data for Lot Number: UL11095 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealylab.com Page 8of Id Inorganic non-metals - MB Sample ID: UQ39973-001 Matrix: Aqueous Batch: 39973 Analytical Method: 16648 Parameter Result Q Dil LOQ DL Units Analysis Date HEM (oil and grease) ND 1 5.0 1.4 1 12/24/2019 0000 L00 = Limit of Duantuation P = The RPD between two GC columns exceeds 40% N = Recovery is out of criteria DL = Detection Limit J e Estimated result n L00 and > OIL += RPO is out of criteria LOD= Limit of Detection NO = Not detected at or above the DL Note: Calculations are performed before rounding to avoid round -off errors in calculated results Shealy Environmental Services, Inc, QC Data for Lot Number: UL11095 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 wvvw.shealylab.com Pagc 9 of 14 Inorganic non-metals - LCS Sample ID: UQ39973-002 Matrix: Aqueous Batch: 39973 Analytical Method: 1664E Spike Amount Result % Rec Parameter (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date HEM (oil and grease) 40 38 1 95 78-114 12/24/2019 0000 L00 = Limit of Ouamitatidn DL = Detection Limit 1_01) = Linia of Detection P = The RPD between two GC columns exceeds 40% N = Recovery is out of criteria J = Estimated result a LOO and > DL • = RPD is out of cursed NO = Not detected at or above the DL Note: Calculations are performed before rounding to avoid round -off errors in calculated results Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (B03) 791-9111 www.shealylab.com QC Data for Lot Number: UL11095 Phgc It ul 14 Inorganic non-metals - MS Sample ID: UL11095-001 MS Matrix: Aqueous Batch: 39973 - Analvtical Method: 1664B Sample Spike Amount Amount Result % Rec Parameter (mg/L) (mg/L) (mg/L) Q Dil % Rec Limit Analysis Date HEM (oil and grease) 38 40 53 N 1 38 78-114 12/24/2019 0000 LOD = Limit of Ouanteatwn DL = Detection Limit LOD = Limit of Detection P =The RPD between two GC columns exceeds 40% N = Recovery Is out of criteria J = Estimated result < LOD and > DL = RPD is out of criteria NO = Not detected at or above the DL Note: Calculations are performed before rounding to avoid round -off errors in calculated results Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealylab. com QC Data for Lot Number: UL11095 liaec I I it 14 Chain of Custody and Miscellaneous Documents Shealy Environmental Services, Inc. 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealylab.com Page 12 ul 14 eo' . SHEALY ENVIRONMENTAL SERVICES. INC. SH EALY Chain at CuSlody Record P-int Drive $IC 29172 I L121 59 Number I_'z� - - ,, --L1 j ULi 1095 I .,.,. .::,i i IT 1D eft C. w) F— C.L'.r- lo > Cn m 0 m Cn z 0 SHEALY ENVIRONMENTAL SERVICES, INC. pz� I )f I Sample Receipt Checklist (SRC) SCIWAIJEL C ' A T 7TIqi,1 I I uej hhlt l J. 1.1: 1 L�•u ,LuT ,oa,, ptrsrN tie Ilin co,-Ivr? -1 Nol NA 2, Vousljdy, th:a' 1111.114 act! inbri,blur., II Ism C.1 le, I Fly'.N. 11, I!tiraiuc ur.:Nu I cciin )nrivrd ((Arrr,.Nr.d) uINN, 'v.X N - '.&"id �ihrji-cup it): NIA NA NaNA :-'-A ethod! CHIP-Mahne, Blau f-JApunt Br)jjjcs IR (-in(] ID: 6 jR r0r.IhL,d Qj C .... 1,,,[ -7 _ Fau0j; 0 M lc; 0 Dry [cc: b Nnua ❑Vn 10 1 ub-, 'onk "CCCLIH wa; Pruie:i I'M X, pilnue ala r.1ce-b'-filce is Nlu "n"), El Ye, C) No I A 4. k fit eOmi —rwr iei cou , i-Pr I-- 5 F3 N, LU.111111', pr*ce Irlei 135te" oil zue"K, 11371C ji6h,d nn IhI, N",W;tsI dite & ICU 1111Ku'd un —at, C1 No 10, Did all c, I \k hthihwrlah�-1 iw2 � JrI lim,�I tgre, fill jtheYES F1 Nn I lu'qul to hr P,--1 forill-"i listed ch' LIe coc" rz Yes 0 12. Did !'I! s,Inupli:s arrive I,, 11h, pro pj3j- n�jjla:lletn: 1-int euch 11,S' auu�orin ,ocd corljivah wx Ye' 13 No hdonitunc 5hu"pt'.'.'Q]umC Nn Weir u1jamile,s jcuQlv,,j rvi I n-h i 01C I GT nCul� InsC N— ,i imu,� 16. l-' �MbwEENj , ,,. Av11901, El Yes In urc il 111C WA ', ijili- 6"", it t Utals. ut!" C: it vemp J" mteivcd it piI U. El �-Cs 0 AVcTc all n-aijjj; swltrLI Yes [01 appwzhir N11........a '14 Ye; ENo ®NA . free. 01 �ielllh 11 21? I—I tuf-j -NA nequns!ed dilulIc-S, MN�.-4sj) Jrsig:ujlir.rs: Ic frc-un the C(X' invi the c,ulllutj 'ection ill MIS? yes, Nr, irlbc!'! Ir 'cc;. NA AUIPIP, h esthwall"'. oc cc-nIPI'lrd Ili: prC.S2nVc'd orN -Iz ------ A . fieadsp,,� aunnizi I NA ."'Obc rrCth'r,'d - ,,Ie,cnkdaernlitin n d -11rc IJLIA,d1 vunplereroIvinit vinn 4"!fCl: KSIJIIu111,SR Na i true of per,+rn'uG1rn N\ Cjc(Bees. jain t1'.o, mcnts Ibbm. NA fecnvcd with buijh[cq.,6 min if; dian't- fiu�lnd ac�ornaiiaj;jy it, "alill"10 I act! wzfe -jjinI j1Na2S:()'I .v,lll S11 11, Q II);NA I)ul'- 1211 lily Shealy Environmental Services, Inc 106 Vantage Point Drive West Columbia, SC 29172 (803) 791-9700 Fax (803) 791-9111 www.shealylab.com Page 14 of 14