HomeMy WebLinkAboutNCG060208_MONITORING INFO_20191204fin/ ,5 R, 0
STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO.
OQO D
DOC TYPE
❑ HISTORICAL FILE
MONITORING REPORTS
L/
DOC DATE
❑
YYYYMMDD
ENVIRONMENTAL • GEOTECHNICAL
BUILDING SCIENCES • MATERIALS TESTING
November 25, 2019
North Carolina Department of Environmental Quality (NCDEQ)
Division of Water Quality
A'I'TN: DWQ Central Files
1617 Mail Service Center
Raleigh, NC 27699-1617
Re: Stormwater Discharge Monitoring Report
Certificate of Coverage NO. NCG060208
Pepsi Bottling Ventures, LLC
3425 Meyer Lce Drive
Winston-Salem, NC
"fo Whom It May Concern:
2725 E. Millbrook Rd., Ste. 121
Raleigh, NC 27604
Telephone 919-871-0999
Fax 919-871-0335
www. alcgroupservices.coni
IEC 04 2019
UVv CTJ0.
ATC Associates of North Carolina, P.C. (ATC), on behalf of Pepsi Bottling Ventures, LLC is
submitting the Semiannual Storm Water Sampling Report for the above referenced site. One
original and one copy of the certified Discharge Monitoring Report (DMR) is included in
Attachment C of the report.
Sincerely,
ATC Associates of North Carolina, P.C.
Gabriel Araos, P.L.
Senior Project Manager
Attachment: Semiannual Stormwater Sampling
cc: Bill Peterson, Pepsi Bottling Ventures, LLC
I
PYRAMID
ENVIRONMENTAL 8 ENGMEERING, P.C.
November 8, 2019
Mr. Gabe Araos
A"fC Group Services, LLC
2725 Millbrook Road
Raleigh, NC 27604
11E: Semi-AnnualStormwaterSampling —2ndHalf 2019
Pepsi Bottling Ventures, 3425 Myer Lee Drive, Winston-Salem, NC
Pyramid Project # 2019-235
Mr. Araos:
As requested by ATC Group Services, I.I.C. Pyramid Environmental & Engineering, P.C. has
completed the stormwater sampling and analysis for the referenced site. The location of the site
is shown on the USGS topographic map presented as Figure 1. A site map showing the existing
building and stormwater Outfall location is presented as Figure 2.
As shown on the site plan, the site was designed to direct all stormwater run-off to a retention
pond on the west side of the property. Water from the retention pond discharges to an overflow
catch basin (Outfall #01) on the north side of the pond and drains west to Lowery Mill Creek
(Salem Lake), which is approximately 1,000 feet from the site.
Sample Collection and Laboratory Analysis
On October 30, 2019, Alan McFadden of Pyramid successfully collected stormwater samples
from Outfall #01 during a representative rain event. The qualitative monitoring report was
completed for Outfal.l 401 by Pyramid and is included in Attachment A. The qualitative
monitoring report describes the visual appearance of the stormwater run-off at the time of the
sampling event. No unusual conditions were observed by Pyramid. The total event precipitation
included on the qualitative form is from the Smith Reynolds Airport and was obtained from the
North Carolina Climate Office, Weather and Climate Database.
The stormwater samples were placed on ice and transported to Research and Analytical
Laboratories, Inc. in Kernersville, North Carolina. The samples were analyzed for oil & grease,
chemical oxygen demand (COD), total suspended solids (TSS) and pH.
The laboratory results of the stormwater samples are presented in Table 1, which is included in
Attachment 13 with a copy of the lab report. As shown in Table 1, the detected concentrations of
oil & grease, COD and TSS in the samples collected from Outfall #01 do not exceed the
benchmark values specified in General Permit NCG060000. The laboratory pl-I reading (5.99)
was slightly outside the specified range of 6.0— 9.0.
P.O. pox 16265 • Greensboro, NC 27416
503 Industrial Ave • Greensboro, NC 27406
Phone (336)335-3174 • Pax (336)691-0648 • Toll Free (866)545-9507
Email: I nfoO)pvram idenv i ronmental.com
wAvw. mymm idenvi ronmental. com
Pyramid also completed the semi-annual stormwater discharge monitoring report (DMR) for
Outfall #01 as specified in General Permit NCG060000. The completed monitoring report is
included as Attachment C. A representative of Pepsi Bottling Ventures is required to sign page
two of the monitoring report and send the original and one copy to the address shown on page
two.
The next semi-annual sampling event will be performed between January 1s` and June 30, 2019.
The samples will be analyzed for the compounds as specified in the general permit. Please
review this information and call me at 335-3174 if you have any questions.
Sincerely,
Brett S. Higgins
Project Manager
Figures & Attachments A, B & C
Pepsi Bottling Ventures — 3425 Myer Lee Drive, Winston-Salem, NC - Stornnvaler Sampling 11108119
Pyramid Project # 2019-235 2
PYRAMID
ENVIRONMENTAL& ENGINEERING, P.C.
ATC Group Services LLC
425 cr Lee Drive
b inston- a em '"'" ort i aro ina
Topographic Map
1' = 2,000'
4 �K `9
uscsroro
1 R "
oe _
R•B I
rxrsE �
NOTES
TVO]WIC WII®MT6
WMC 8 WP�q 81R01 .VQ
QD�QC TRA.. 8]YlfI108 C(
KR88 OON NON
R
0
, An
I >g
I
1 1
r
I �
r ,
I r
I i (—
I
II
'+
1 1
� �
1
0
Y,
N^�AHAH��
I�
C
NFA
�
I
A
r
n
m
I
A
m
~
1 O
> 1
9n x�m
os�
t rluumL c
SITE MAP
PEPSI—COLA BOTTLING COMPANY
OF WINSTON—SALEM
WINSTON—SALEM, NORTH CAROLINA
fiAspE t.rEm� rl¢r.p
1253352.d:g CY
u iC
x 550 CI '
yR NaNCM�� Sl6d ry19) pI p�1LpW F/J( l9191011d113
pENE o x r E � rwlEcr xa.
i"=150' 01—i1-2008 45.27087,7005
m-
Environmental
Quality
Stormwater Discharge Outfall (SDO)
Qualitative Monitoring Report
For guidance onfilling out lhisjorm, please visit littys://deg.nc.gov/about/divisions/enerev-mineral-land-
reso urces/enerev-mineral-I an d-perm i is/storm water-pe rm it shi pd es-industrial-swktab-4
Permit No.: N/C/G/ 0 / 6 /0 /0 / 0 / 0/ or Certificate of Coverage No.: N/C/G/0/ 6/0 / 2 /0/ 8/
Facility Name: Pepsi Bottling Ventures - 3425 Myer Lee Drive, Winston-Salem NC
County: Forsyth t- ee Phone No. (336) 748-0440
Inspector: P, l-c1 dl v,-
Date of Inspection: 1,3
Time of Inspection: 1
Total Event Precipitation (incites): 1p
All permits require qualitative monitoring to be performed during a `measurable storm event."
A "measurable storm event" is a storm event that results in an actual discharge from the permitted site
outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm
interval does not apply if the perminee is able to document that a shorter interval is representative for
local storm events during the sampling period, and the penmittee obtains approval from the local DEMLR
Regional Office.
By this signature, I certify that this report is accurate and complete to the best of my knowledge:
(Signature of Permittee or Designee)
I
1. Outfall Description:
Outfall No. 901 Structure (pipe, ditch, etc.): Overflow inlet structure for retention pond
Receiving Stream:
Lowery Mill Creek (Salem Lake)
Describe the industrial activities that occur within the outfall drainage area: Truck & trailer parking
raw material and finished product loading and unloading
Page I of 2
SWU-242, Last madilied 07/282017
2. Color: Describe the color o
(light, medium, dark) as descriptors:
3. Odor: Describe any
chlorine odor, etc.): in t�_
colors (red, brown, blue, etc.) and tint
t odors that the discharge may have (i.e., smells strongly of oil, weak
4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear
and 5 is very cloudy: 0
2 3 4 5
5. Floating Solids: Choose the number which best describes the amount of floating solids in the
stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids:
�l 2 3 4 5
6. Suspended Solids: Choose the number which best describes the amount of suspended solids in
the stormwater discharge, where I is no solids and 5 is extremely muddy:
7.
8.
9.
J 2 3 4 5
Is there any foam in the stormwater discharge? Q Yes X No.
Is there an oil sheen in the stormwater discharge? oYes X No.
Is there evidence of erosion or deposition at the outfall? O Yes A No.
10. Other Obvious Indicators of Stormwater Pollution:
List and describe Nn ajkl tf OLl'G41 1AdieetfC%ri o652i>aJedt
Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be
indicative of pollutant exposure. These conditions warrant further investigation.
Page 2 of 2
SWU-242, Last modified 07/28/2017
ATTACHMENT B
TABLE 1
Stormwater Analytical Results for Outfall #01
Pepsi Bottling Ventures
3425 Myer Lee Drive, Winston-Salem, NC
-c
LaboratoryResults
;- PARAMETER
-UNITS
Date. i
�BenchmarkiConcentration'
per General Permii"'
}`-,,Outfall
#01°
-
- NCG660000 -
09/26/18
< 5
04/05119
<5
Oil & Grease
. mg/L `.
30 mg/L
10130/19
<5
-
-
-
09/26/18
14.7
04/05/19
10.4 -
Total SuspendedSolids
-- mg/L, ,.
100 mg/L
10/30/19
10.4
09/26/18
NA
04/05/19
23
Chemical Oxygen Demand
"mg/L "'
120 mg/L
10/30/19
25
(COD);:
-_
s
"'a
09/26/18
6.29
'Standard-
6.0-9.0
04/05/19
6.40
10/30/19
5.99
z
NA: Not Analyzed for this parameter
Page 1 of 1
RESEARCh & ANAtyTiCA[
LAbORATORiES, INC.
For: Pyramid Environmental
503 Industrial Avenue
Greensboro, NC 27406
Ann: Brett Higgins
Report of Analysis
11 /6/2019
copy f. CH q ?!_Z
ca
¢'07 NC034 0z'9'
NC#37701
:DigE�pPyync ,
�'**; IA7ED 0 o`"
Client Sample ID: Pepsi Bottling Ventures Myer Lee Dr. Outfall Lab Sample ID: 74157-01
#01
(Site: Pyramid Environmental Collection Date: 10/302019 17:10
Parameter Method Result Units Rep Limit Analyst Analysis Daterrime
COD EPA410.4 25 mg/L 5 HW 11/12019
Hydrocarbon O&G EPA 1664 Revision B/Silica <5 .mg/L 5 EE 10/312019
pH SM 4500 H+B-2000 5.99 Std. Units LP 10/312019 1429
Total Suspended Solids (TSS) SM 2540 D-1997 10.4 mg/L 5 AW 11/12019
NA = not onolyzed
North Carolina 27284 Tel: 336-996-2841 Fax: 336-996-0326 v .randalabs.com Page 1
RESEARCh A ANA1yTICA1
LAbORATORIES, INC.
Analytical / Process Consultations
Phone (336) 996-2841
CHAIN OF CUSTODY RECORD
COMPANY Pyramid Environmental
Y
JOB No.
2019-235.
3
G
z
yo. o;
d2
y rr�� p0'mp or
o`Ps� o�Q���$?"0c,`o�po`o
ti p^Q• 0 Q' Q' Q' cZ
ry ry ry �� y REQUESTED ANALYSIS
STREETADDRESS
503 Industrial Avenue
PROJECT Pepsi Bottling Ventures
Myer Lee Dr. W-S
CITY, STATE, ZIP
Greensboro, NC 27406
SAMPLER NAME (PLEASE PRINT)
Alan McFad en
CONTACT PHONE
Brett Higgins 336-335-3174�
SAMPLER SIGNATURE
SAMPLE NUMBER
(IAB USE ONLY)
DATE
TWE
CO
GRAB
N
.0
RE$
G
roq
w�a
RvM
SAMPLE LOCATION I I.D.
X1
w
Outfall #01
1
1
ixixix
O&G TSS COD & pH
R14OUISHED YY
ARELINQUISHED
DATEITIIMME
RECEIVED BY
REMARKS:
SAMPLE TEMPERATUREATR EIPTC -- °C
BY
DAjyrIME
�h
RECEIVED BY
SEMI-ANNUAL STORMWATER DISCHARGE MONITORING REPORT
for North Carolina Division of Water Resources General Permit No. NCG060000
Date submitted October 30, 2019
CERTIFICATE OF COVERAGE NO. NCG060 2 0 8
FACILITY NAME Pepsi Bolting Ventures - 3425 Meyer Lee Drive, Winston-Salem, NC
COUNTY Forsvth
PERSON COLLECTING SAMPLES Alan McFadden
LABORATORY Research & Analytical Labomiones Lab Cent. # 34
Part A: Stormwater Benchmarks and Monitoring Results
SAMPLE COLLECTION YEAR 2019
FACILITY ACTIVITIES INCLUDE (check all that apply):
❑ use/process meats ❑ use animal fats/byproducts
DISCHARGING TO SALTWATERS? DYES ❑■ NO
PLEASE REMEMBER TO SIGN ON THE REVERSE 4
Total event rainfall
22.66 or ❑ No discharge this period'
Outfall No.
Sample Collected,
mo/dd/yr
TSS,
mg/L
pH,
Standard units
COD,
mg/L
Oil and Grease,
mg/L
Fecal Coliform ,
Colonies per 100 ml
Enterococci ,
Colonies_ per 100 ml
Benchmark
-
100or50
Within 6.0-9.0
120
30
1000
500 -
#01
10/30/19
10.4
5.99
25
<5
NA
NA
' Only applies to facilities that use/process meats.
'The total precipitation must be recorded using data from an on -site rain gauge.
' For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here.
°See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? ❑ yes J no (if ves, complete Part B)
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month.
Outfall No.
Sample Collected,
mo/dd/yr
Oil and Grease,
mg/L
TSS,
_ mg/L
pH,
Standard units
New Motor Oil Usage,
Annual average gal/mo
Benchmark
-
30
100 or 50
6.0-9.0
-
' Only applies to facilities that use/process meats.
'The total precipitation must be recorded using data from an on -site rain gauge.
' For sampling periods with no discharge at any outfalls, you must still submit this discharge monitoring report with a checkmark here.
°See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
SWU-249 Last Revised: October 18. 2012
Page I of 2
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging> 55 gal of new motor oil/month.
OuHall No.
Date Sample Collected
(mo/dd/yr)
24-hour rainfall amount,
Inches
New Motor Oil or
Hydraulic Oil Usage
Non -Polar O&G/Total
Petroleum Hydrocarbons
Total Suspended Solids
Benchmarks
-
-
-
15 mg/L
100 mg/L or 50 mg/N
Parameter Code
-
46529
NCOIL
00s52
C0530
Footnotes from Part A also apply to Part B
*FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO Q
IF YES, HAVE YOU CONTACTED THE DEMUR REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
.Mail an original copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end ofmonitoring period in the case
of "No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, NC 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system
designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who
manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and
belief, true, accur d complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and
imprisonmen or know g violations."
.i
Si a of Permittee D e
Permit Date: 11/1/2018-05/31/2021
SWU-249, Last Revised 11/5/2018
Page 2 of 2
EMI -ANNUAL STORMWATER DISCHARGE MONITORING REPORT
for North Carolina Division of Water Resources General Permit No. NCGO60000
Date submitted October 30, 2019
CERTIFICATE OF COVERAGE NO. NCG060 2 0 8
FACILITY NAME Pepsi Bottling Ventures -3425 Meyer Lee Drive, Winston-Salem, NC
COUNTY Forsyth
PERSON COLLECTING SAMPLES Alan McFadden
LABORATORY Research & Analytical Laboratories Lab Cert. # 34
Part A: Stormwater Benchmarks and Monitoring Results
SAMPLE COLLECTION YEAR 2019
FACILITY ACTIVITIES INCLUDE (check all that apply):
❑ use/process meats ❑ use animal fats/byproducts
DISCHARGING TO SALTWATERS? AYES ❑S NO
PLEASE REMEMBER TO SIGN ON THE REVERSE 4
Total event rainfa/122.66 or n No dischorae this oeriod3
Outfall N�oY.F'rSamplerjCollected
t.. �ymo/dd/,yr--:. ,
,.t ,-TSS�
c s img/L t,,
1pH
iStandard•units,h
,yCOD x
,,,-:1mg/L�. 4
?OII a�nd`Gieas `,y
rfa: _ : Emg/L day-
r:.,Ftecal4Cohfo"rm F
�JColomes;pe'r;1D0 mh;,
w r�Ente ococc
Colonie's,per,100 ml."':
:BendBrnark_
,' - - `' ;
300ioi?50-`!
Within,6:0'L 9i0,,.
120f'
' 30' '� ` - '
t `a r1000,
- '=. y500, _
#01
10130119
10.4
5.99
25
15
NA
NA
' Only applies to facilities that use/process meats. _
2The total precipitation must be recorded using data from an on -site rain gauge.
3 For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here.
4See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? [:]yes Q✓ no (if ves, complete Part B)
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month.
' jpiu all'.No 41
�i
1Sa`6iplVC61Iected t
.tmo/dd/yr,. ,-,
?Od andlGr`ease
, +;mg/L„ . ,
1;`� jTSS;ir
mg/L'+t -� x
s pH,`r �` -
L,�Standard',umtsl ..
`' ?New'Motor 011 Usa e
g,
;yAnnuahaverage gal/mo; �s
.Be`ncFimaik'`"'''•
.. -__ .. -n
- ;':30L
t " :r100;o iSOr »";
,;' ,16.0 _9 0.
Only applies to facilities that use/process meats.
2The total precipitation must be recorded using data from an on -site rain gauge.
3 For sampling periods with no discharge at any outfalls, you must still submit this discharge monitoring report with a checkmark here.
4See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
SWU-249 Last Revised: October 18, 2012
Page 1 of 2
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging> 55 gal of new motor oil/month
OuNall No:
Date Sample Collected
(mo/dd/yr)
24-hour rainfallamount,
Inches'
New Motor Oil or
Hydraulic Oil Usage
Non Polar O&G/Total
Petroleum Hydrocarbons
Total Suspended Solids
Benchmarks
-
-'
15 mg/L
100 mg/L or 50 mg/L°
Parameter Code.
-
465,29
NCOIL
00552
C0530
Footnotes from Part A also apply to Part B
*FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS, SEE PERMIT PART 11 SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO Q
IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑NO❑
REGIONAL OFFICE CONTACT NAME:
Mail an original copy of this DMR, including all "No Discharge' reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case
of "No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, NC 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system
designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who
manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and
belief, true, accur , d complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and
imprisonmen or know' gviolations,"
Ay�_
Si a of Permittee D e
Permit Date: 11/l/2018-05/31/2021 SWU-249, Last Revised 11/5/2018
Page 2 of 2