Loading...
HomeMy WebLinkAboutNCG060208_MONITORING INFO_20191204fin/ ,5 R, 0 STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. OQO D DOC TYPE ❑ HISTORICAL FILE MONITORING REPORTS L/ DOC DATE ❑ YYYYMMDD ENVIRONMENTAL • GEOTECHNICAL BUILDING SCIENCES • MATERIALS TESTING November 25, 2019 North Carolina Department of Environmental Quality (NCDEQ) Division of Water Quality A'I'TN: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 Re: Stormwater Discharge Monitoring Report Certificate of Coverage NO. NCG060208 Pepsi Bottling Ventures, LLC 3425 Meyer Lce Drive Winston-Salem, NC "fo Whom It May Concern: 2725 E. Millbrook Rd., Ste. 121 Raleigh, NC 27604 Telephone 919-871-0999 Fax 919-871-0335 www. alcgroupservices.coni IEC 04 2019 UVv CTJ0. ATC Associates of North Carolina, P.C. (ATC), on behalf of Pepsi Bottling Ventures, LLC is submitting the Semiannual Storm Water Sampling Report for the above referenced site. One original and one copy of the certified Discharge Monitoring Report (DMR) is included in Attachment C of the report. Sincerely, ATC Associates of North Carolina, P.C. Gabriel Araos, P.L. Senior Project Manager Attachment: Semiannual Stormwater Sampling cc: Bill Peterson, Pepsi Bottling Ventures, LLC I PYRAMID ENVIRONMENTAL 8 ENGMEERING, P.C. November 8, 2019 Mr. Gabe Araos A"fC Group Services, LLC 2725 Millbrook Road Raleigh, NC 27604 11E: Semi-AnnualStormwaterSampling —2ndHalf 2019 Pepsi Bottling Ventures, 3425 Myer Lee Drive, Winston-Salem, NC Pyramid Project # 2019-235 Mr. Araos: As requested by ATC Group Services, I.I.C. Pyramid Environmental & Engineering, P.C. has completed the stormwater sampling and analysis for the referenced site. The location of the site is shown on the USGS topographic map presented as Figure 1. A site map showing the existing building and stormwater Outfall location is presented as Figure 2. As shown on the site plan, the site was designed to direct all stormwater run-off to a retention pond on the west side of the property. Water from the retention pond discharges to an overflow catch basin (Outfall #01) on the north side of the pond and drains west to Lowery Mill Creek (Salem Lake), which is approximately 1,000 feet from the site. Sample Collection and Laboratory Analysis On October 30, 2019, Alan McFadden of Pyramid successfully collected stormwater samples from Outfall #01 during a representative rain event. The qualitative monitoring report was completed for Outfal.l 401 by Pyramid and is included in Attachment A. The qualitative monitoring report describes the visual appearance of the stormwater run-off at the time of the sampling event. No unusual conditions were observed by Pyramid. The total event precipitation included on the qualitative form is from the Smith Reynolds Airport and was obtained from the North Carolina Climate Office, Weather and Climate Database. The stormwater samples were placed on ice and transported to Research and Analytical Laboratories, Inc. in Kernersville, North Carolina. The samples were analyzed for oil & grease, chemical oxygen demand (COD), total suspended solids (TSS) and pH. The laboratory results of the stormwater samples are presented in Table 1, which is included in Attachment 13 with a copy of the lab report. As shown in Table 1, the detected concentrations of oil & grease, COD and TSS in the samples collected from Outfall #01 do not exceed the benchmark values specified in General Permit NCG060000. The laboratory pl-I reading (5.99) was slightly outside the specified range of 6.0— 9.0. P.O. pox 16265 • Greensboro, NC 27416 503 Industrial Ave • Greensboro, NC 27406 Phone (336)335-3174 • Pax (336)691-0648 • Toll Free (866)545-9507 Email: I nfoO)pvram idenv i ronmental.com wAvw. mymm idenvi ronmental. com Pyramid also completed the semi-annual stormwater discharge monitoring report (DMR) for Outfall #01 as specified in General Permit NCG060000. The completed monitoring report is included as Attachment C. A representative of Pepsi Bottling Ventures is required to sign page two of the monitoring report and send the original and one copy to the address shown on page two. The next semi-annual sampling event will be performed between January 1s` and June 30, 2019. The samples will be analyzed for the compounds as specified in the general permit. Please review this information and call me at 335-3174 if you have any questions. Sincerely, Brett S. Higgins Project Manager Figures & Attachments A, B & C Pepsi Bottling Ventures — 3425 Myer Lee Drive, Winston-Salem, NC - Stornnvaler Sampling 11108119 Pyramid Project # 2019-235 2 PYRAMID ENVIRONMENTAL& ENGINEERING, P.C. ATC Group Services LLC 425 cr Lee Drive b inston- a em '"'" ort i aro ina Topographic Map 1' = 2,000' 4 �K `9 uscsroro 1 R " oe _ R•B I rxrsE � NOTES TVO]WIC WII®MT6 WMC 8 WP�q 81R01 .VQ QD�QC TRA.. 8]YlfI108 C( KR88 OON NON R 0 , An I >g I 1 1 r I � r , I r I i (— I II '+ 1 1 � � 1 0 Y, N^�AHAH�� I� C NFA � I A r n m I A m ~ 1 O > 1 9n x�m os� t rluumL c SITE MAP PEPSI—COLA BOTTLING COMPANY OF WINSTON—SALEM WINSTON—SALEM, NORTH CAROLINA fiAspE t.rEm� rl¢r.p 1253352.d:g CY u iC x 550 CI ' yR NaNCM�� Sl6d ry19) pI p�1LpW F/J( l9191011d113 pENE o x r E � rwlEcr xa. i"=150' 01—i1-2008 45.27087,7005 m- Environmental Quality Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance onfilling out lhisjorm, please visit littys://deg.nc.gov/about/divisions/enerev-mineral-land- reso urces/enerev-mineral-I an d-perm i is/storm water-pe rm it shi pd es-industrial-swktab-4 Permit No.: N/C/G/ 0 / 6 /0 /0 / 0 / 0/ or Certificate of Coverage No.: N/C/G/0/ 6/0 / 2 /0/ 8/ Facility Name: Pepsi Bottling Ventures - 3425 Myer Lee Drive, Winston-Salem NC County: Forsyth t- ee Phone No. (336) 748-0440 Inspector: P, l-c1 dl v,- Date of Inspection: 1,3 Time of Inspection: 1 Total Event Precipitation (incites): 1p All permits require qualitative monitoring to be performed during a `measurable storm event." A "measurable storm event" is a storm event that results in an actual discharge from the permitted site outfall. The previous measurable storm event must have been at least 72 hours prior. The 72-hour storm interval does not apply if the perminee is able to document that a shorter interval is representative for local storm events during the sampling period, and the penmittee obtains approval from the local DEMLR Regional Office. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) I 1. Outfall Description: Outfall No. 901 Structure (pipe, ditch, etc.): Overflow inlet structure for retention pond Receiving Stream: Lowery Mill Creek (Salem Lake) Describe the industrial activities that occur within the outfall drainage area: Truck & trailer parking raw material and finished product loading and unloading Page I of 2 SWU-242, Last madilied 07/282017 2. Color: Describe the color o (light, medium, dark) as descriptors: 3. Odor: Describe any chlorine odor, etc.): in t�_ colors (red, brown, blue, etc.) and tint t odors that the discharge may have (i.e., smells strongly of oil, weak 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: 0 2 3 4 5 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: �l 2 3 4 5 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where I is no solids and 5 is extremely muddy: 7. 8. 9. J 2 3 4 5 Is there any foam in the stormwater discharge? Q Yes X No. Is there an oil sheen in the stormwater discharge? oYes X No. Is there evidence of erosion or deposition at the outfall? O Yes A No. 10. Other Obvious Indicators of Stormwater Pollution: List and describe Nn ajkl tf OLl'G41 1AdieetfC%ri o652i>aJedt Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 SWU-242, Last modified 07/28/2017 ATTACHMENT B TABLE 1 Stormwater Analytical Results for Outfall #01 Pepsi Bottling Ventures 3425 Myer Lee Drive, Winston-Salem, NC -c LaboratoryResults ;- PARAMETER -UNITS Date. i �BenchmarkiConcentration' per General Permii"' }`-,,Outfall #01° - - NCG660000 - 09/26/18 < 5 04/05119 <5 Oil & Grease . mg/L `. 30 mg/L 10130/19 <5 - - - 09/26/18 14.7 04/05/19 10.4 - Total SuspendedSolids -- mg/L, ,. 100 mg/L 10/30/19 10.4 09/26/18 NA 04/05/19 23 Chemical Oxygen Demand "mg/L "' 120 mg/L 10/30/19 25 (COD);: -_ s "'a 09/26/18 6.29 'Standard- 6.0-9.0 04/05/19 6.40 10/30/19 5.99 z NA: Not Analyzed for this parameter Page 1 of 1 RESEARCh & ANAtyTiCA[ LAbORATORiES, INC. For: Pyramid Environmental 503 Industrial Avenue Greensboro, NC 27406 Ann: Brett Higgins Report of Analysis 11 /6/2019 copy f. CH q ?!_Z ca ¢'07 NC034 0z'9' NC#37701 :DigE�pPyync , �'**; IA7ED 0 o`" Client Sample ID: Pepsi Bottling Ventures Myer Lee Dr. Outfall Lab Sample ID: 74157-01 #01 (Site: Pyramid Environmental Collection Date: 10/302019 17:10 Parameter Method Result Units Rep Limit Analyst Analysis Daterrime COD EPA410.4 25 mg/L 5 HW 11/12019 Hydrocarbon O&G EPA 1664 Revision B/Silica <5 .mg/L 5 EE 10/312019 pH SM 4500 H+B-2000 5.99 Std. Units LP 10/312019 1429 Total Suspended Solids (TSS) SM 2540 D-1997 10.4 mg/L 5 AW 11/12019 NA = not onolyzed North Carolina 27284 Tel: 336-996-2841 Fax: 336-996-0326 v .randalabs.com Page 1 RESEARCh A ANA1yTICA1 LAbORATORIES, INC. Analytical / Process Consultations Phone (336) 996-2841 CHAIN OF CUSTODY RECORD COMPANY Pyramid Environmental Y JOB No. 2019-235. 3 G z yo. o; d2 y rr�� p0'mp or o`Ps� o�Q���$?"0c,`o�po`o ti p^Q• 0 Q' Q' Q' cZ ry ry ry �� y REQUESTED ANALYSIS STREETADDRESS 503 Industrial Avenue PROJECT Pepsi Bottling Ventures Myer Lee Dr. W-S CITY, STATE, ZIP Greensboro, NC 27406 SAMPLER NAME (PLEASE PRINT) Alan McFad en CONTACT PHONE Brett Higgins 336-335-3174� SAMPLER SIGNATURE SAMPLE NUMBER (IAB USE ONLY) DATE TWE CO GRAB N .0 RE$ G roq w�a RvM SAMPLE LOCATION I I.D. X1 w Outfall #01 1 1 ixixix O&G TSS COD & pH R14OUISHED YY ARELINQUISHED DATEITIIMME RECEIVED BY REMARKS: SAMPLE TEMPERATUREATR EIPTC -- °C BY DAjyrIME �h RECEIVED BY SEMI-ANNUAL STORMWATER DISCHARGE MONITORING REPORT for North Carolina Division of Water Resources General Permit No. NCG060000 Date submitted October 30, 2019 CERTIFICATE OF COVERAGE NO. NCG060 2 0 8 FACILITY NAME Pepsi Bolting Ventures - 3425 Meyer Lee Drive, Winston-Salem, NC COUNTY Forsvth PERSON COLLECTING SAMPLES Alan McFadden LABORATORY Research & Analytical Labomiones Lab Cent. # 34 Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 FACILITY ACTIVITIES INCLUDE (check all that apply): ❑ use/process meats ❑ use animal fats/byproducts DISCHARGING TO SALTWATERS? DYES ❑■ NO PLEASE REMEMBER TO SIGN ON THE REVERSE 4 Total event rainfall 22.66 or ❑ No discharge this period' Outfall No. Sample Collected, mo/dd/yr TSS, mg/L pH, Standard units COD, mg/L Oil and Grease, mg/L Fecal Coliform , Colonies per 100 ml Enterococci , Colonies_ per 100 ml Benchmark - 100or50 Within 6.0-9.0 120 30 1000 500 - #01 10/30/19 10.4 5.99 25 <5 NA NA ' Only applies to facilities that use/process meats. 'The total precipitation must be recorded using data from an on -site rain gauge. ' For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here. °See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? ❑ yes J no (if ves, complete Part B) Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month. Outfall No. Sample Collected, mo/dd/yr Oil and Grease, mg/L TSS, _ mg/L pH, Standard units New Motor Oil Usage, Annual average gal/mo Benchmark - 30 100 or 50 6.0-9.0 - ' Only applies to facilities that use/process meats. 'The total precipitation must be recorded using data from an on -site rain gauge. ' For sampling periods with no discharge at any outfalls, you must still submit this discharge monitoring report with a checkmark here. °See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. SWU-249 Last Revised: October 18. 2012 Page I of 2 Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging> 55 gal of new motor oil/month. OuHall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/N Parameter Code - 46529 NCOIL 00s52 C0530 Footnotes from Part A also apply to Part B *FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO Q IF YES, HAVE YOU CONTACTED THE DEMUR REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: .Mail an original copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results for at end ofmonitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accur d complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonmen or know g violations." .i Si a of Permittee D e Permit Date: 11/1/2018-05/31/2021 SWU-249, Last Revised 11/5/2018 Page 2 of 2 EMI -ANNUAL STORMWATER DISCHARGE MONITORING REPORT for North Carolina Division of Water Resources General Permit No. NCGO60000 Date submitted October 30, 2019 CERTIFICATE OF COVERAGE NO. NCG060 2 0 8 FACILITY NAME Pepsi Bottling Ventures -3425 Meyer Lee Drive, Winston-Salem, NC COUNTY Forsyth PERSON COLLECTING SAMPLES Alan McFadden LABORATORY Research & Analytical Laboratories Lab Cert. # 34 Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 FACILITY ACTIVITIES INCLUDE (check all that apply): ❑ use/process meats ❑ use animal fats/byproducts DISCHARGING TO SALTWATERS? AYES ❑S NO PLEASE REMEMBER TO SIGN ON THE REVERSE 4 Total event rainfa/122.66 or n No dischorae this oeriod3 Outfall N�oY.F'rSamplerjCollected t.. �ymo/dd/,yr--:. , ,.t ,-TSS� c s img/L t,, 1pH iStandard•units,h ,yCOD x ,,,-:1mg/L�. 4 ?OII a�nd`Gieas `,y rfa: _ : Emg/L day- r:.,Ftecal4Cohfo"rm F �JColomes;pe'r;1D0 mh;, w r�Ente ococc Colonie's,per,100 ml."': :BendBrnark_ ,' - - `' ; 300ioi?50-`! Within,6:0'L 9i0,,. 120f' ' 30' '� ` - ' t `a r1000, - '=. y500, _ #01 10130119 10.4 5.99 25 15 NA NA ' Only applies to facilities that use/process meats. _ 2The total precipitation must be recorded using data from an on -site rain gauge. 3 For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here. 4See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? [:]yes Q✓ no (if ves, complete Part B) Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month. ' jpiu all'.No 41 �i 1Sa`6iplVC61Iected t .tmo/dd/yr,. ,-, ?Od andlGr`ease , +;mg/L„ . , 1;`� jTSS;ir mg/L'+t -� x s pH,`r �` - L,�Standard',umtsl .. `' ?New'Motor 011 Usa e g, ;yAnnuahaverage gal/mo; �s .Be`ncFimaik'`"'''• .. -__ .. -n - ;':30L t " :r100;o iSOr »"; ,;' ,16.0 _9 0. Only applies to facilities that use/process meats. 2The total precipitation must be recorded using data from an on -site rain gauge. 3 For sampling periods with no discharge at any outfalls, you must still submit this discharge monitoring report with a checkmark here. 4See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. SWU-249 Last Revised: October 18, 2012 Page 1 of 2 Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging> 55 gal of new motor oil/month OuNall No: Date Sample Collected (mo/dd/yr) 24-hour rainfallamount, Inches' New Motor Oil or Hydraulic Oil Usage Non Polar O&G/Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - -' 15 mg/L 100 mg/L or 50 mg/L° Parameter Code. - 465,29 NCOIL 00552 C0530 Footnotes from Part A also apply to Part B *FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS, SEE PERMIT PART 11 SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO Q IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑NO❑ REGIONAL OFFICE CONTACT NAME: Mail an original copy of this DMR, including all "No Discharge' reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accur , d complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonmen or know' gviolations," Ay�_ Si a of Permittee D e Permit Date: 11/l/2018-05/31/2021 SWU-249, Last Revised 11/5/2018 Page 2 of 2