Loading...
HomeMy WebLinkAboutNCG060184_MONITORING INFO_20191113WE STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. NCG �� NY DOC TYPE ❑ HISTORICAL FILE C� MONITORING REPORTS DOC DATE ❑ �� �( 113 YYYYM M D D STORMWATER DISCHARGE MONITORING REPORT for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG060000 Date submitted November 5, 2019 CERTIFICATE OF COVERAGE NO. NCG06 0 1 8 4 FACILITY NAME Pilgrim's Pride Corporation, Wingate Feed Mill 8 Truck Shop COUNTY Union PERSON COLLECTING SAMPLES Hayne Haigler LABORATORY Environmental Chemists, inc. Lab Cert. fi 94 SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ❑■ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA �+ QOther REGE F}A�CIL RY ACTIVITIES INCLUDE (check all that apply): NOV 13 201SE] use/process meats ❑ use animal fats/byproducts CENTRAFLL FILE DWR S-PC€A> !REMEMBER TO SIGN ON THE REVERSE 4 Part A: Stormwater Benchmarks and Monitoring Results Total event rainfall' 0.3 " or ❑ No discharge this period' Outfall No. Date sample Collected, mo/dd/yr TSS, mg/L pH, Standard units COD, mg/L Oil and Grease, mg/L Fecal Coliform, Colonies per 100 ml Enterococci, Colonies per 100 ml Benchmark - 100 or 504 Within 6.0 — 9.0 120 30 30001 5001 Parameter Code' - C0530 00400 00340 00556 31616 61211 #001A 10/16/2019 3.2 7.14 <20 <5,0 161 4002A 10/162019 6.3 6,71 21 <5.0 119 1 Only applies to facilities that use/process meats. 'The total precipitation must be recorded using data from an on -site rain gauge. 3 For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here. 'See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 'Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new oil per month? ❑■ yes ❑ no (if yes• complete Part B) Permit Date: 11/1/2018-05/31/2021 SWU-249, Last Revised 11/5/2018 Page 1 of 2 Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month. Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inchesz New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/Total Petroleum Hydrocarbons Total Sus ended Solids P Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/L4 Parameter Code - 46529 NCOIL 00552 C0530 #001A 10/16/2019 0.3 107 < 5.0 3.2 #002A 10/16/2019 0.3 107 < 5.0 6.3 Footnotes from Part A also apply to Part B *FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES Q NO ❑ IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES Q NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original copy of this DMR including all "No Discharge" reports within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of /-/0—/y Date Permit Date: 11/1/2018-05/31/2021 SWU-249, Last Revised 11/5/2018 Page 2 of 2 Environmental Chemists, Inc. 6602 Windmill Way, Wilmington, NC 28405 • 910.392.0223 Lab • 910.392.4424 Fax 4mc- 710 Bowsertown Road, Manteo, NC 27954 • 252.473.5702 Lab/ Fax 255-A Wilmington Flighway, Jacksonville, NC 28540 • 910.347.5843 Lab/Fax ANALYTICAL & CONSULTING CHEMISTS info u)environmentalchemists.com Pilgrim's Pride -Wingate Date of Report: Oct 30, 2019 205 Edgewood Drive Customer PO #: Wingate NC 28174 Customer ID: 17040004 Attention: Report #: 2019-17536 Project ID: Wingate Feed Mill -Storm Water Lab ID Sample ID: Collect Date/Time Matrix Sampled by 19-44822 Site: Outfall #1A 10/16/2019 11:00 AM Water Hayne Haigler Test Method Results Date Analyzed Oil & Grease (0&G) Fecal Coliform Residue Suspended (TSS) pH COD Comment: Reviewed by: EPA 1664 Ideu Colilert-16 SM 2540 D SM 4500 H B SM 5220D <5 mg/L 161 MPN/100ml 3.2 mg/L 7.14 units <20 mg/L 10/18/2019 10/16/2019 10/17/2019 10/25/2019 10/23/2019 Report #:: 2019-17536 Panc i nl � Environmental Chemists, Inc. envirochem ANALYTICAL & CONSULTING CHEMISTS LCS 6602 Windmill Way, Wilmington, NC 28405 . 910.392.0223 Lab • 910.392.4424 Fax 710 Bowsertown Road, Manteo, NC 27954 • 252.473.5702 Lab/Fax 255-A Wilmington highway, Jacksonville, NC 28540 • 910.347.5843 Lab/Fax info u�environmentaichemistscom Pilgrim's QC - 2019-17536 Parameter True Value nig/L Result nig/L %True Value Limits % COD 1000 1014 101 90-110 Fecal N/A N/A N/A N/A TSS 92.5 88.0 95 82.4-118 PH zoo 7.01 too 90-110 OIL &GREASE 40.0 40.9 102 78-114 MS/MSD Parameter True Value m 1L Recovery mg/L % Recovery % Difference Limits % Recovery Limits Difference COD 50.0 1.0 1081112 4 80-120 <_20 Fecal N/A N/A N/A N/A N/A N/A TSS N/A N/A N/A N/A N/A N/A PH N/A N/A N/A N/A N/A N/A OIL &GREASE 40.0 35.2 88 N/A 78-114 < 18 DUPLICATE SAMPLES Parameter Results mg/L %Difference Limits Vo COD N/A N/A N/A < 10 Fecal <2 <2 0 < 30 TSS 87.0 92.0 6 < 10 PH 8.35 8.35 0 < 10 OII_ & GREASE N/A N/A N/A N/A �envirochem ANALYTICAL & CONSULTING CHEMISTS BLANK Environmental Chemists, Inc. 6602 Windmill Way, Wilmington, NC 28405 • 910.392.0223 Lab • 910.3924424 Fax 710 Bowsertown Road, Manteo, NC 27954 • 252.473.5702 Lab/Fax 255-A Wilmington Flighway, Jacksonville, NC 28540 • 910.3,17.5843 Lab/Fax info(u environment:dchemists.com Parameter Results nrg/L Limn nag/L COD <10 10 Fecal (Start Control) 0 0 TSS <2.5 2.5 pl-1 N/A N/A OIL & GREASE <2.5 2.5 ENVIRONMENTAL CHEMISTS, INC NCDENR: DWO CERTIFICATION # 94 NCDHHS: DLS CERTIFICATION # 37729 COLLECTION AND CHAIN OF CUSTODY 6602 Windmill Way Wilmington, NC 28405 OFFICE: 910-392-0223 FAX 910-3924424 into Oenvironmentalchemists.com Client: Pilgrim's Pride Corporation r.PROJECT if NAME: 1 e Storm Wa er (plant) REPORT NO: [� ADDRESS: Z05a tW CONTACT NAME: George Chang PO NO: ,„ 1° (^ Z9/ REPORT TO: PHONE/FAX: 704.624.4317 COPY TO: email: yin-pong.chang@pilgrims.com Sampled By: SAMPLE TYPE: I = Influent, E = Effluent, W = Well, ST = Stream, SO = Soil, St. = Sludge, Other: Sample Identification Collection a " Q. n o m E CJ m o` e d _o` rn c E m m j Z PRESERVATION ANALYSIS REQUESTED Date Time Temp w Q u g N - z a _ o 2 w w o Outfall #1 !0 /11:00 C P U`A 1'{giZ X X X TSS, H,COD,OiI & Grease,Fecal Colifo G G C P G G C P G G C P G G C P G G C P G G C P G G C P G G C P G G Transfer Relinquished By: Daterrime Received By: Date/Time 1. 2. Temperature when Received: Accepted: Rejected: Resample Requested: Delivered Bv: Received Bv: Date - TURNAROUND: _Environmental Chemists, Inc. 0 6602 Windmill Way, Wilmington, NC 28405 • 910.392.0223 Lab • 910.392.4424 Fax 710 I3owsertown Road, Manteo, NC 27954 • 252.473.5702 Lab/Fax 255-A Wilmington Highway, Jacksonville, NC 28540 • 910.347.5843 Lab/Fax ANALYTICAL & CONSULTING CHEMISTS info a�envi I oil menlalchemisls.com Pilgrim's Pride -Wingate Date of Report: Oct 30, 2019 205 Edgewood Drive Customer PO #: Wingate NC 28174 Customer ID: 17040004 Attention: Report #: 2019-17533 Project ID: Wingate Feed Mill -Storm Water Lab ID Sample ID: Collect DatelTime Matrix Sampled by 19-44820 Site: Outfall #2A 10/16/2019 11:00 AM Water Hayne Haigler Test Method Results Date Analyzed Oil & Grease (O&G) EPA 1664 <5 mg/L 10/18/2019 Fecal Coliform IoemColilert-i6 119MPN/100ml 10/16/2019 Residue Suspended (TSS) SM25400 6.3mg/L 10/17/2019 COD SM 5220D 21 mg/L 10/23/2019 Comment: Reviewed by Report p,: 2019-17533 Page 1 of 1 Environmental Chemists, Inc. `�envrrochem ANALYTICAL & CONSULTING CHEMISTS LCS 6602 Windmill Way, Wilmington, NC28405 • 910.392.0223 Lab • 910.3924424 Fax 710 Bowsertown Rood Nlanteo, NC 27954 • 252.473.5702 Lab/Fax 255-A Wilmington Highway, Jacksonville, NC 28540 • 910.347.5843 Lab/Fax info@ environmentalchemists.com Pilgrim's QC- 2019-17533 Parameter True Vcdue m /L Result mg/L %True Value Limits COD 1000 1014 101 90-110 Fecal N/A N/A N/A N/A TSS 92.5 88.0 95 82.4-118 OIL & GREASE(OPR) 40.0 40.9 102 78-114 MS/MSD Parometer True Value rng/L Recovery mg/1, % Recovery % Difference Limils % Recovery Limits Yo Difference COD 50.0 54/56 108/112 4 80-120 < 20 Fecal N/A N/A N/A N/A N/A N/A TSS N/A N/A N/A N/A N/A N/A OIL & GREASE 40.0 35.2 88 N/A 78-114 < 18 DUPLICATE SAMPLES Parameter Results mg/L % Dilffrence Limils COD N/A N/A N/A < 10 Fecal <2 <2 0 <30 TSS 87.0 92.0 6 < 10 OIL & GREASE N/A N/A N/A N/A " 3 � v h enviroc ANALYTICAL & CONSULTING CHEMISTS .i1_1� 1.1 Environmental Chemists, Inc. 6602 Windmill Way, Wilmington, NC 28405 • 910.392.0223 Lab • 910.392.4424 Fax 710 13owsertown Road, Manteo, NC 27954 - 252.473.5702 Lab/Fax 255-A Wilmington Highwav, Jacksonville, NC 28540 • 910.347.5843 Lab/Fax info a cnvironmentalchcmists.com Parameter Results mg/L Linn! nag/L COD <10 10 Fecal (Start Control) 0 0 TSS <2.5 2.5 OIL & GREASE <2.5 2.5 Poo 6602 Windmill Way NC ENVIRONMENTAL CHEMISTS, INC OFFI E: 91013 2-02 3'lFAX9910 92 42245 Analytical &Consulting Chemists NCDENR: DWO CERTIFICATION N 94 NCDHHS: DLS CERTIFICATION a 37729 infoOenvironmentalchemists.com COLLECTION AND CHAIN OF CUSTODY Client: Pilgrim's Pride Corporation PROJECT NAME: rR4eretweHe Storm r ater (plant) REPORT NO: Ici ��� �� ADDRESS. .Z0$ CONTACT NAME: George Chang PO NO: REPORT TO: PHONEIFAX: 704.624.4317 COPY TO: email: yin-pong.chang@pilgrims.com Sampled By: SAMPLE TYPE: I = Influent, E = Effluent, W = Well, ST = Stream, SO = Soil, SL = Sludge, Other: Sample Identification Collection K m n y a c a n o m E m Z cc7 e o n " _ d 0 a` m c E " a ow m m j Z PRESERVATION ANALYSIS REQUESTED Date Time Temp w u $ w i _ x a o i w r o Outfall #x Z c/6/zoi ( =oo C P L I-Vt4 X X X TSS, COD,Oil & Grease,Fecal Colifo G G G G�rc�e11 C P G G C P G G C P G G C P G G C P G G C P G G C P G G Transfer Relinquished By: Daterrime Received By: Datet7ime 1. 2. Temperature when Received: Accepted: Rejected: Resample Req Delivered Bv: Received Bv: Date: TURNAROUND: STORMWATER DISCHARGE MONITORING REPORT for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG060000 CERTIFICATE OF COVERAGE NO. NCG06 0 1 8 4 FACILITY NAME Pilgrim's Pride Corporation, Wingate Feed Mill 8 Truck COUNTY Onion PERSON COLLECTING SAMPLES Hayne Haigler LABORATORY Environmental Chemists, inc. Lab Cert. # 94 Part A: Stormwater Benchmarks and Monitoring Results Date submitted November 5, 2019 SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June ❑ July -Dec or ❑■ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑N Other FACILITY ACTIVITIES INCLUDE (check all that apply): ❑ use/process meats ❑ use animal fats/byproducts PLEASE REMEMBER TO SIGN ON THE REVERSE 4 Total event rainfall 2 0.3 " or ❑ No discharge this period' Outfall No. Date Sample Collected, mo/dd/yr TSS, mg/L pH, Standard units COD, mg/L Oil and Grease, mg/L Fecal Coliform, Colonies per 100 ml Enterococci, Colonies per 100 ml Benchmark - 100 or 504 Within 6.0 — 9.0 120 30 10001 Soo' Parameter Code - C0530 00400 00340 00556 31616 61211 #001A 10/16/2019 3.2 7.14 <20 <5.0 161 #002A 10/162019 6.3 fi 71 21 < 5.0 119 1 Only applies to facilities that use/process meats. 'The total precipitation must be recorded using data from an on -site rain gauge. 3 For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here. 4See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. 'Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new oil per month? ❑■ yes ❑ no (if yes, complete Part B) Permit Date:11/1/2018-05/31/2021 SWU-249, Last Revised 11/5/2018 Page 1 of 2 Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month. Outfall No. Date Sample Collected (mo/dd/yr) 24-hour rainfall amount, Inches New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 mg/L 100 mg/L or 5o mg/L4 Parameter Code - 46529 NCOIL 00552 CO530 #001A 10/16/2019 0.3 107 <5.0 3.2 #002A 10/16/2019 0.3 107 - 5.0 6.3 Footnotes from Part A also apply to Part B *FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES Q NO ❑ IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES Q NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original copy of this DMR including all "No Discharge" reports within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Signature of Perm Date Permit Date:11/1/2018-OS/31/2021 SWU-249, Last Revised 11/5/2018 Page 2 of 2 ANALYTICAL & CONSULTING CHEMISTS Environmental Chemists, Inc. 6602 Windmill Way, Wilmington, NC 25405 • 910392,0223 lab • 910.39?.4424 Fax 710 Bowsortmt n Rued, Manteu, NC 27951 - 252.473.5702 Lab/Fax 255-A Wilmington f lighwaY, Jacksonville, NC 28540 • 910.347,5543 Lab/Fax into tenvironmentalchcmistsc0m Pilgrim's Pride -Wingate Date of Report: Oct 30, 2019 205 Edgewood Drive Customer PO #: Wingate NC 28174 Customer ID: 17040004 Attention: Report #: 2019-17536 Project ID: Wingate Feed Mill -Storm Water Lab ID Sample ID: Collect Date[Time Matrix Sampled by 19-44822 Site: Outfall #1A 10/16/2019 11:00 AM Water Hayne Haigler Test Method Results Date Analyzed Oil & Grease (0&G) EPA 1664 <5 mg/L 10/18/2019 Fecal Coliform ideucomert-la 161 MPN/100ml 10/16/2019 Residue Suspended (TSS) SM 2540 0 3.2 mg/L 10/17/2019 pH SM 4500 H s 7.14 units 10/25/2019 COD SM 52200 <20 mg/L 10/23/2019 Comment: Reviewed by: p,1 Report #.: 2019-17536 env�rocle � ANALYTICAL & CONSULTING CHEMISTS LCS Environmental Chemists, Inc. 6602 Windmill Wav, Wilmington, NC 28405 . 910 392.0223 Lab = 910.392.4424 Fax 710 Bowsertown Road, �lanteo, MC 27954 + 252.473.5702 Lab/Fax 255-A Wilmington hiigh�, ,Y. Jacksonville, NC 28540 e 910347.5843 Lab/Fax infoli �nvironntcnFalcL•Cmists.com Pilprim's QC - 2019-17536 Parameter True Value mg/L Result nig/L % True Vulue Limits % COD 1000 1014 101 90-110 Fecal N/A N/A N/A N;A TSS 92.5 88.0 95 82.4-118 pH 7.00 7.01 100 90-110 OIL & GREASE 40.0 40.9 102 78-114 MS/MSD Parameter True Kalue mg/L Recovery nsgrl % Recovery % Drfference Limits % Recovery Limits Dil rence COD 50.0 1.0 108/112 4 80-IN <2o Fecal N/A N/A NI.A N/A N/A N/A TSS N/A N.A N/A N/A N/A N/A pH N,,A N/A N/A N/A Nl.4 N1.4 OIL & GREASE 40.0 35.2 88 N/A 78-114 < 18 DUPLICATE SAMPLES Parameter R&S'1f1t.0 mg/L %Difference Limits % COD N/A' N'A N/A < 10 Fecal <2 <2 0 < 30 TSS 87.0 92.0 6 < 10 pH 8.35 8.35 0 < 1 o OIL & GREASE N/A N/A N/A N/A Environmental Chemists, Inc. a o e 7t e' �t t_N ANALYTICAL & CONSULTING CHEMISTS = 6602 Windmill Way, Wilminotoi i, NC 28405 • 910.392.0223 I_ab * 910.392.4424 Fax 710 6owsertown Road, Nlanteo, NC 27954 . 252.473.5702 Lab/Faz 255-A Wilmington Highway, Jacksonville, N`C 28540 • 910_3475843 Lab/Fax inloi7ijenviron men talchem i;ts.eom Parameter• Results mg/L Limi[ mg/L COD <io 10 Fecal (Start Control) 0 0 TSS <2.5 2.5 pH N/A N/A O[[. & GREASE < . 2.5 21 Analytical & Consulting Chemists ENVIRONMENTAL CHEMISTS, INC NCDENR: DWO CERTIFICATION # 94 NCDHHS: DLS CERTIFICATION # 3T729 Cnl I FCTInN ANn CHAIN r111: CI IQTnnV 6602 Windmill Way Wilmington, NC 28405 OFFICE: 910-392-0223 FAX 910-392-4424 info Oenvironmentalchemists.com Client: Pilgrim's Pride Corporation _ 1 1 PROJECT NAME: Storm Wa er (plant) REPORT NO: ADDRESS: Wd,- 205& CONTACT NAME: George Chang PO NO: i n C C 7S/ REPORT TO: PHONE/FAX: 704.624.4317 COPY TO: email: yin-pong.chang@pilgrims.com Sampled Bv: Hu.awe 14&;400_✓ SAMPI F TVPr- I - IMI.—i C _ CNL.e 1 w _ ue,n Cr Sample Identification Collection & d E y m a o" E 0 u 2 5 `o ° u 8 o E E m m ' 2 _ PRESERVATION ANALYSIS REQUESTED Date Time Temp w o _ a 4 i = � °a = p a i o Outfall #1 /D : Do C P `A X X X TSS,pH,COD,Oil & Grease,Fecal Colifo G G C P G G C P G G C P G G C P G G C P G G C P G G C P G G C P G G Transfer Relinquished By: Date/Time Received By: Date/Time 1. 2. Tmm�n..f...e...6e., Delivered mple mequesrea: TURNAROUND: Environmental Chemists, Inc. p 6602 Windmill Way, Wilming:nn, tiC? 405 910 �920223 i ah - 9111,392.4424 Fax ' 710 6owsertown Road, iManteo, NC 27954 252 a73 5 02Lab/Fax 255-A Wilmington Highway, Iacksom ille, iAC 26540 • 910.547 564; Lab/'Fax ANALYTICAL & CONSULTING CHEMISTS info::: cn�ironmcntalchcmistscom Pilgrim's Pride -Wingate Date of Report: Oct 30, 2019 205 Edgewood Drive Customer PO #: Wingate NC 28174 Customer ID: 17040004 Attention: Report #: 2019-17533 Project ID: Wingate Feed Mill -Storm Water Lab ID Sample ID: Collect Date/Time Matrix Sampled by 19-44820 Site: Outfall #2A 10/16/2019 11:00 AM Water Hayne Haigler Test Method Results Date Analyzed Oil & Grease (O&G) EPA 1664 <5 mg/L 10!18/2019 Fecal Coliform Ide" Convert-19 119 MPN/100ml 10/16/2019 Residue Suspended (TSS) sM 2540 D 6.3 mg/L 10/17/2019 COD Ski 52201) 21 mg/L 10/23/2019 Comment: Reviewed by: Report 9- 2019-17533 Page 1 of 1 Environmental Chemists-, Inc. 40:51, M11 -, "WM 1 ANALYTICAL & CONSULTING CHEMISTS LCS 6602 Windmill Way, Wilmington, NC 28405 • 910.392.0223 Lab - 910.392.4424 Fax 710 Bowsertnwn Road, Nlanteo, NC 27954 • 252.473.3702 I-ab/Fax 255-A Wilmington Highway, Jacksonville, NC 28540 a 910.3473843 Lab/Fax inli:�menvi I onmen[xlchemis!c.com Pilgrim's QC- 2019-17533 Parameter True Value mg'L Result mg1,L %True 1 alue Limits yo COD 1000 1014 101 90-110 Fecal N/A N/A N/A N/A TSS 92.5 88.0 95 82.4-118 OIL & GREASE(OPR) 40.0 40.9 102 78-1 l4 NiS/MSD Pcrra/deter True Value mg/L Recovery Yiig11. % Recovery yo D!%fe/'eY1C'e Limits No RC'LY)Vel'y Limits ib D[jfL'YC'31CL' COD 50.0 54/56 108/112 4 80-120 <20 Fecal NrA N%A N,A N/A N/A N/A TSS N/A N%A N/A N/A N/A N/A OIL, & GREASE 40.0 35.2 88 NiA 78-I l4 < Is DUPLICATE SAMPLES Parameter Results mg/L % Dif,renee Limits % COD N/A N/A N/A < 10 Fecal <2 <2 0 <30 TSS 87.0 92.0 6 < 10 OIL & GREASE- NIA NIA N/A N/A Envlr®nment'al Chemists, Inc. 6; A A q ?ji'.y'���j,�d �v� 'SM ANALYTICAL & CONSULTING CHEMISTS BLANK 6602 Windmill Way, Wiimington, NC: 28405 , 910.392.0223 Lab o 910.392.44424 Fax i10 f3ow,er, wn Road, \iantco NV279aL 1 2;2,473 702 Lab/Fax 2»Ab\ilminntuntlighwav,Jac ksomiile,NC28i1) • 910 -1 5S' Lab/F:, info�igenvirurn:er•talchemistv.ciun Parameter Results mg/L Limil rrtg/Z COD <I0 10 Fecal (Start Control) 0 0 TSS <2 i z.5 OIL & GREASE: <1 2.5 'I ee ENVIRONMENTAL CHEMISTS, INC 6602 Windmill ay Wilmington,23 FAX 9C 28405 �#:: Analytical & Consulting Chemists NCDENR: DWO CERTIFICATION It 94 NCDHHS: DLS CERTIFICATION # 37729 infoOenvironmentalchemists.com rill I AKIM nll n�•� nr Client: Pilgrim's Pride Corporation V VV !ft e " I PROJECT NAME:-MeraNarm Water (plant) iHSto REPORT NO: ADDRESS. Z05E49ewb.ACONTACT NAME: George Chang PO NO: i$I W= 2.e 74 REPORT TO: PHONEIFAX: 704.624.4317 COPY TO: email: yin-pong.chang@pilgrims.com SAMPI. F TYPF• I - Infl... m c - cNl.,e. ! w _ w..0 Sample Identification Collection g = m �, d a - E° t7 U v _ c a° U d 2 ' t E U m Q E J Z _...__..,.._.._..,...-.......,.,.,.,..-.,vn, PRESERVATION .ate-�muyc, vurcr. ANALYSIS REQUESTED Date Time Temp i i I S i om 2 0 i o w o Outtall tk orb/zol I(-- =oD C P V1 KL� X X X TSS, ,COD,OiI & Grease,Fecal Colifo G G C P C P G G C P G G C P G G C P G G C P G G C P G G C P G G Transfer Relinquished By: Daterrime Received By: Date/Time 1. 2. Temperature when Rereivwi n....e„.,,a. ---- ----- - - •-rv�•�� nesample nequesiea:_ Delivered By: _ _____Received By:Date: Times - TURNAROUND: