Loading...
HomeMy WebLinkAboutNCG060040_MONITORING INFO_20190717vv SD STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. lv C 6 C`/ 0 DOC TYPE ❑ HISTORICAL FILE ❑MONITORING REPORTS DOC DATE ❑ g o,� U-71 7 YYYYMMDD �7 �y�s MOUNT-VERNON CHEMICALS, LLC 2001 Willow Springs Lane, Burlington, North Carolina 27215, PHONE 336-506-0524 FAX 336-228-6963 July 10, 2019 Central Files Division of Water Quality 1617 Mail Service Center Raleigh, INC 27699-1617 Re: 2019 Semi -Annual NPDES Stormwater Report General Permit: NCG060000 COC No: NCG060040 Mount Vernon Chemicals, LLC / Apollo Chemical — Burlington Facility 2001 Willow Springs Lane Burlington, INC 27215 Enclosed are the original and a copy of the stormwater monitoring results for the first half of 2019 for our Willow Springs Lane facility. Our four stormwater outfalls were sampled during a significant rain event (documentation is attached). On -site measurement of pH was conducted at Apollo Chemical at the time of sampling. The samples were sent to Meritech, Inc. (Lab Certification No: 165) for analysis. The samples were tested for TSS, COD, and Oil & Grease. The Meritech report is appended. Our "Stormwater discharge outfall monitoring report' which includes pH results, is also appended. If you need additional information, please contact me. Sincerely, RECEIVED Mount Vernon Chemicals, LLC/Apollo Chemical JUL 17 2019 /� CENTRAL FILES v i DWR SECTION Gary S. Dagenhart, Ph.D. Vice -President — Chemical Technology Custom Manufacturing / R&D / Regulatory Compliance gdagenhart(a)apollochemical.com Phone 336-506-0524 Copy: Plant Managers, Regulatory File, Corporate Director Environmental Affairs Apollo Chemical 2001 Willow Springs Lane, Burlington, North Carolina 27215 Tel 336-226-1161 Fax 336-228-6963 www. a p o l l o c h e m i ca I. co m SEMI-ANNUAL STORMWATER DISCHARGE MONITORING REPORT for North Carolina Division of Water Quality General Permit No. NCG060000 Date submitted 7/10/2019 CERTIFICATE OF COVERAGE NO. NCG060040 SAMPLE COLLECTION YEAR January -June 2019 FACILITY NAME Mount Vernon Chemicals, LLC dba Apollo Chemical FACILITY ACTIVITIES INCLUDE (check all that apply): COUNTY Alamance ❑ use/process meats ❑ use animal fats/byproducts PERSON COLLECTING SAMPLES Shawn Rudison DISCHARGING TO SALTWATERS? ❑YES X NO LABORATORY Meritech, Inc Lab Cert. # 165 Part A: Stormwater Benchmarks and Monitoring Results PLEASE REMEMBER TO SIGN ON THE REVERSE 4 Total event rainfall 20. 14 inches or ❑ No discharge this period' Outfall No. Sample Collected, mo/dd/yr TSS, mg/L pH, Standard units COD, mg/L Oil and Grease, mg/L Fecal Coliformr, Colonies. per 100 ml Enterococci', Colonies per 100 ml Benchmark - 100or504 Within 6.0 — 9.0 120 30 1000 Soo SDO-1 06/20/19 8 6.6 28 < 5 N/A N/A SDO-2 06/20/19 41 6.3 30 < 5 N/A N/A SDO-3 06/20/19 23 6.3 37 < 5 N/A N/A SDO-4 06/20/19 30 6.4 45 < 5 N/A N/A 1 Only applies to facilities that use/process meats. 2The total precipitation must be recorded using data from an on -site rain gauge. 3 For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here. 4See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month? ❑ yes X no Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month. Outfall No. Sample Collected, mo/dd/yr Oil and Grease, mg/L TSS, mg/L pH, Standard units New Motor Oil Usage, Annual average gal/mo Benchmark - 30 100 or 504 6.0-9.0 - 1 Only applies to facilities that use/process meats. 2The total precipitation must be recorded using data from an on -site rain gauge. 3 For sampling periods with no discharge at any outfalls, you must still submit this discharge monitoring report with a checkmark here. (ifyes complete Part B) 4See General Permit text, Table 3, identifying the especially sensitive receiving water classifications where the more protective benchmark applies SWU-249 Last Revised: October 18, 2012 Page I of 2 *FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER ATTHE SAME OUTFALLTRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this DMR, including all "No Discharge" reports, within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, NC 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." (Signature of Permittee) July 10, 2019 (Date) Additional copies of this form may be downloaded at: http://Portal.ncdenr.ors/web/wq/ws/su/npdessw#tab-4 S W U-249 Last Revised: October 18, 2012 Pale 2 of 2 O Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidanceonfi/ling out thisform, please visit: http://h2o.enr.state.nc.us/su/Forms Documents.htm#miseforms Permit No.: N/C/ G/0 / 6/0/ 0/ 0/ 0/ or Certificate of Coverage No.: N/C/G/ 0/ 6/0/4 /0 /0 / Facility Name: Mount Vemon Mills, Inc / Mount Vernon Chemicals. LLC / Apollo Chemical County: Alamance Phone (336) 506-0524 No. Inspector: Shawn Rutllson Date of Inspection: 06/20/2019 Time of Inspection: 2:15 - 2:30 PM Total Event Precipitation (inches): 0144 Was this a Representative Storm Event? (See information below) Yes No Please check your permit to verify if Qualitative Monitoring must be performed during a representative storm event (requirements vary). A "Representative Storm Event" is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no precipitation. By this signature, I certify that this report is accurate and complete to the best of my knowledge: G5 D (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. soO1 Structure (pipe, ditch, etc.) PIPE Receiving Stream: GUNN CREEK Describe the industrial activities that occur within the outfall drainage area: CHEMICAL MANUFACTURING 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: CLEAR, COLORLESS 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): NONE Page] oft SWU-242-112608 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: 1 5. Floating Solids: Choose the number which best describes the amount of lloating solids in the stormwater discharge, where I is no solids and 5 is the surface covered with floating solids: 1 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where I is no solids and 5 is extremely muddy: 1 7. Is there any foam in the stormwater discharge? No 8. Is there an oil sheen in the stormwater discharge? No 9. Is there evidence of erosion or deposition at the outfall? No 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant Further investigation. Page 2 of 2 S W U-242-1 12609 a Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance onfilling out thisform, please visit: htto:/ih2o.enr.state.nc.us/su/Forms Documents.htm#miscforms Permit No.: N/C/ G/0 / 6/0/ 0/ 0/ 0/ or Certificate of Coverage No.: N/C/G/ 0/ 6/0/4/0 /0 / Facility Name: Mount Vemon Mills. Inc/ Mount Vemon Chemicals, LLC / Apollo Chemical County: Alamance Phone (336) 506-0524 No. Inspector: Shawn Rudison Date of Inspection: 06/20/2019 Time of Inspection: 2:15 - 2:30 PM Total Event Precipitation (inches): 0.14 Was this a Representative Storm Event? (See information below) Yes ❑ No Please check your permit to verify if Qualitative Monitoring must be performed during a representative storm event (requirements vary). A "Representative Storm Event' is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no precipitation. By this signature, I certify that this report is accurate and complete to the best of my knowledge: Cs� D (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. SD02 Structure (pipe, ditch, etc.) PIPE Receiving Stream: GUNN CREEK Describe the industrial activities that occur within the outfall drainage area: CHEMICAL MANUFACTURING 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: CLEAR, COLORLESS 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): NONE Page I of 2 S W U-242-1 12608 4. Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: 1 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where I is no solids and 5 is the surface covered with floating solids: 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where I is no solids and 5 is extremely muddy: 7. Is there any foam in the stormwater discharge? No S. Is there an oil sheen in the stormwater discharge? No 9. Is there evidence of erosion Co' deposition at the outfall? No 10. Other Obvious Indicators ol'Stornnvater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of loam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 6RIN19 MIFFZdM Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance onfrllingoutthisform,please visit: http://h2o.enr.state.nc.us/su/Forms Documents.htm#miscforms Permit No.: N/C/ G/0 / 6/0/ 0/ 0/ 0/ or Certificate of Coverage No.: N/C/G/ 0/ 6/0/4 /0 /0 / Facility Name: Mount Vernon Mills Inc / Mount Vernon Chemicals LLC / Apollo Chemical County: Alamance Phone (336) 506-0524 No. Inspector: Shawn Rudison Date of Inspection: 06/20/2019 Time of Inspection: 2:15-2:30 PM Total Event Precipitation (inches): 0.14 Was this a Representative Storm Event? (See information below) Yes No Please check your permit to verify if Qualitative Monitoring must be performed during a representative storm event (requirements vary). A "Representative Storm Event' is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no precipitation. By this signature, 1 certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) Outfall Description: Out£all No. SD03 Structure (pipe, ditch, etc.) PIPE Receiving Stream: GUNNCREEK Describe the industrial activities that occur within the outfall drainage area: CHEMICAL MANUFACTURING 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: CLEAR, COLORLESS 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): NONE Pagel of 2 SWU-242-112608 4. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwatcr discharge, where I is no solids and 5 is the surface covered with floating solids: 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwatcr discharge; where I is no solids and 5 is extremely muddy: 1 7. Is there any foam in the stormwater discharge? No 8. Is there an oil sheen in the stormwater discharge? No 9. Is there evidence of erosion or deposition at the outfall? No 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 S W U-242-1 12608 a Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance onfillingout thisform,please visit: htti):Hh2o.enr.state.nc.us/su/Forms Documents.htmffmiscforms Permit No.: N/C/ G/O / 6/ 0 / 0/ 0/ 0/ or Certificate of Coverage No.: N/C/G/ 0/ 6 / 0 /4 /0 /0 / Facility Name: Mount Vernon Mills Inc /Mount Vernon Chemicals LLC / Apollo Chemical County: Alamance Phone (336) 506-0524 No. Inspector: Shawn Rudison Date of Inspection: 06/20/2019 Time of Inspection: 2:15 - 2:30 PM Total Event Precipitation (inches): 0.14 Was this a Representative Storm Event? (See information below) Yes No Please check your permit to verify if Qualitative Monitoring must be performed during a representative storm event (requirements vary). A "Representative Storm Event' is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1 inches has occurred. A single storm event may contain up to 10 consecutive flours of no precipitation. By this signature, I certify that this report is accurate and complete to the best of my knowledge: G5 D (Signature of Permittee or Designee) 1. Outfall Description: Outfall No. so04 Structure (pipe, ditch, etc.) PIPE Receiving Stream: GUNNCREEK Describe the industrial activities that occur within the outfall drainage area: CHEMICAL MANUFACTURING 2. Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: CLEAR, COLORLESS 3. Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): NONE Page] of 2 SWU-242-112608 d. Clarity: Choose the number which best describes the clarity of the discharge, where 1 is clear and 5 is very cloudy: 1 5. Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where I is no solids and 5 is the surface covered with floating solids: 6. Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 7. Is there any foam in the stormwater discharge? No 8. Is there an oil sheen in the stormwater discharge? No 9. Is there evidence of erosion or deposition at the outfall? No 10. Other Obvious Indicators of Stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 S W U-242-1 12608 Meritech, Inc. Environmental Laboratory Laboratory Certification No.165 Contact: Shawn Rudison Report Date: 7/3/2019 Client: Apollo Chemical 2001 Willow Spings Ln Burlington, NC 27216 Date Sample Rcvd: 6/21/2019 Meritech Work Order # 06211984 Sample: SDO1 Grab 6/20/19 Parameters Result Analysis Date Reporting Limi Method COD 28 mg/L 7/2/19 15 mg/L EPA 410.4 Total Suspended Solids 8 mg/L 6/25/19 2.5 mg/L SM 2540 D Oil & Grease (HEM) <5 mg/L 6/25/19 5 mg/L EPA 1664B Meritech Work Order # 06211985 Sample: SD02 Grab 6/20/1.9 Parameters Result Analysis Date Reporting Ural Method COD 30 mg/L 7/2/19 15 mg/L EPA 410.4 Total Suspended Solids 41 mg/L 6/25/19 2.5 mg/L SM 2540 D Oil & Grease (HEM) <5 mg/L 6/25/19 5 mg/L EPA 1664B Meritech Work Order # 06211986 Sample: SD03 Grab 6/20/19 Parameters Restilt Analysis Date Reporting Limit Method COD 37 mg/L 7/2/19 15 mg/L EPA 410.4 Total Suspended Solids 23 mg/L 6/25/19 2.5 mg/L SM 2540 D Oil & Grease (HEM) <5 mg/L 6/25/19 5 mg/L EPA 1664B Meritech Work Order # 06211987 Sample: SDO4 Grab 6/20/19 Parameters Resu t Analysis Date Reporting Liml Method COD 45 mg/L 7/2/19 15 mg/L EPA 410.4 Total Suspended Solids 30 mg/L 6/25/19 IS mg/L SM 2940 D Oil & Grease (HEM) <5 mg/L 6/25/19 5 mg/L EPA 1664B I hereby certify thatl have reviewed and approve this data. 642 Tamco Road, Reidsville, North Carolina 27320 tel.(336)342-4748 fax.(336)342-1522 Chain of Custody Record COC Client: Address: Attention: Apollo Chemical 2001 Willow Springs Ln Burlington, NC 27216 Shawn Rudison NPDES#: Phone: 336-506-0532 Fax: Email: srudisonronaoollochemical com Project: PO #: MERITECH INC. _ Environmental Laboratories A Division of water Technology and control, Inc. 642 Tamco Rd Phone 1-336-342-4748 Reidsville, NC Fax: 1-336-342-1522 27320 Email: wtclab(ftellsouth.net Web Site: www.meritech-laba.com Turn Around Time' Std(10 days) X 3-5Day O 24-48Hr 0 Sample Location/ID # Sampling Dates &Times Person Taking Sample (Signature): Lab Use Only START END Comp? Grab? #of cone. Tests Required On Ice? pH OK? C12 OK? Data Time Date Time SDO1 6/20119 2:15pm 3 Oil+Grease, COD, TSS I 8`4 Yes SD02 6/20/19 2:20pm 3 Oil+Grease, COD, TSS 55 Yes SD03 6/20/19 2:25pm 3 Oil+Grease, COD, TSS L, t7 Yes SD04 6/20119 2:30pm 3 Oil+Grease, COD, TSS Yes Method of Shipment: Comments: ❑ UPS Fed Ex Fj Hand Delivery ❑other Will these results be used for regulatory purposes? Yes x No `RUSH work must be approved prior to submitting samples. Rel,Inquished��\ Date: Time: -jam _ ti,n-�-=V�t�> emnots �1 S Received by: Date: Time: Relinquished by: Date: Time: Receive by: Date: Time: Relinquished by: Date: Time: Receive Dat : Time: Chain of Custody Record COC Client: Address: Attention: Apollo Chemical 2001 Willow Springs Ln Burlington, NC 27216 Shawn Rudison NPDES#: Phone: 336-506-0532 Fax: Email: srudisonrOaoollochemical.Com Project: PO #: MERITECHINC. Environmental Laboratories A Division of water Technology and control, Inc. 642 Tamco Rd Phone 1-336-342-4748 Reidsville, NC Fax: 1-336-342-1522 27320 Email: wtclab(&bellsouth.net Web Site: www.meritech-labs.com Turn Around Time' Std (10 days) X 3 -5 Day E 24 -48 Hr o Sample Location/ID# Sampling Dates & Times Person Taking Sample (Signature): Lab Use Only START END Comp? Grab? A! of Cents. Tests Required Q On Ice? pH OK? ci2 OK? Date Time Date Time SDO1 6120119 2:15pm 3 Oil+Grease, COD, TSS '' G{{`T Yes SD02 6120119 2:20pm 3 Oil+Grease, COD, TSS 55 Yes SD03 6/20/19 2:25pm 3 Oil+Grease, COD, TSS G Yes SD04 6120/19 2:30pm 1 3 Oil+Grease, COD, TSS Yes Method of Shipment: Comments: UPS Fed Ex Hand Delivery Other Will these results be used for regulatory purposes? Yes X No *RUSH work must be approved prior to submitting samples. Relinquishedly: Date: Time: Nw��t,�,,'ux` snvzots Received by Date: Time: Relinquished by: Date: Time: Receive by: Date: Time: Relinquished by: Date: Time: Receive Oat : is a l j (c Time: 17 05 Attached is the Rainfall record for the Burlington Airport for the Storm Water Monitoring Sample collected on June 20, 2019, collected from 2:15pm—2:30pm. The rain gauge at the Apollo Chemical Burlington Facility measured the even to be 0.14 inches at the time of collection. The pH of each sample was measured using a calibrated electrode using buffer 4, buffer 7, and buffer 10. The samples were equilibrated to a temperature of 20.3°C prior to sampling. SDO-1: pH 6.6 SDO-2: pH 6.3 SDO-3: pH 6.3 SDO-4: pH 6.4 Mount Vernon Chemicals, LLC Shawn Rudison Chemical Regulatory Manager Research and Development / Regulatory Compliance Group Apollo Chemical 336.506.0532 srudison@apollochemical.com