HomeMy WebLinkAboutNCG060023_MONITORING INFO_20200102W/o
STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO.
C- G
DOC TYPE
❑ HISTORICAL FILE
Cj MONITORING REPORTS
DOC DATE
❑ ��v v Dl V
YYYYM M D D
Tyson
December 19. 2019
Department of Environment and Natural Resources
Division of Water Quality, Central Files
1617 Mail Service Center
Raleigh, NC 27699 -1617
RE: 2019 Period 2 and Tier Two Monthly Discharge Report
Tyson Farms, Inc.
Monroe, Union County, North Carolina
General Permit Number: NCG06000
Dear Sir/Madam:
RprN .�,,,
BAN O 2 202J ..:
OG,y f rill F p
C"T�0z�
Per the requirements of General Permit No. NCG060000, enclosed are two copies of the 2019
(period 2) stormwater analytical monitoring results for the Tyson Farms, Inc. Monroe Complex
to include the monthly discharge report for outfall #007.
Outfall #7, which is the discharge from the on property stormwater pit, was above the COD and
TSS benchmarks for three consecutive sampling periods. This location remains in Tier Two.
Monthly sampling for COD and TSS is being conducted at outfall #7.
If you have any questions, please contact me at (704) 296-4959 or via email at
chris.harrington@tyson.com.
Sincerely,
Chris Harrington, CHMM
Complex Environmental Manager
Tyson Farms, Inc. Monroe, NC Complex 233 S. Secrest Ave., Monroe NC 28112
(704) 296-490o Fax: (704) 296-4904 % w .tysonfoods.com
STORMWATER DISCHARGE MONITORING REPORT
for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG060000
CERTIFICATE OF COVERAGE NO. NCG06 0 0 2 3
FACILITY NAME Tyson Farms, Inc.
COUNTY Union
PERSON COLLECTING SAMPLES Chris
LABORATORY PAR Labs
Lab Cert. # 20
Part A[ Stnrmwater Benchmarks and Monitorine Results
Date submitted 12/19/19
SAMPLE COLLECTION YEAR 2019
SAMPLE PERIOD ❑ Jan -June ❑■ July -Dec
or I Monthly' (month)
DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
❑Zero -flow [:]WaterSupply ❑SA
❑Other
FACILITY ACTIVITIES INCLUDE (check all that apply):
❑■ use/process meats ❑■ use animal fats/byproducts
PLEASE REMEMBER TO SIGN ON THE REVERSE 4
Total event rainfall20.65 or n No discharge this period'
Outfall No.
Date Sample
Collected, mo/dd/yr
TSS,
mg/L
pH,
Standard units
COD,
mg/L
Oil and Grease,
mg/L
Fecal Coliform,
Colonies per 100 ml
Enterococci,
Colonies per 100 ml
Benchmark
-
100or504
Within 6.0 — 9.0
120
30
1000'
500'
Parameter Code
-
C0530
00400
00340
00556
31616
61211
007
11/12/19
1382
7.33
601
<5.7
200
N/A
010
11/12/19
63
7.42
117
<6
195
N/A
' Only applies to facilities that use/process meats.
2The total precipitation must be recorded using data from an on -site rain gauge.
3 For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here.
4See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
'Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new oil per month? ❑■ yes ❑ no (ifyes, complete Part B)
Permit Date:11/1/2018-05/31/2021
SWU-249, Last Revised 11/5/2018
Page 1 of 2
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month.
Outfall No.
Date Sample Collected
(mo/dd/yr)
24-hour rainfall amount,
Inches2
New Motor Oil or
Hydraulic Oil Usage
Non -Polar 0&G/Total
Petroleum Hydrocarbons
Total Suspended Solids
Benchmarks
-
-
-
15 mg/L
100 mg/L or 50 mg/L4
Parameter Code
-
46529
NCOIL
00552
C0530
009
11/12/19
0.65
101 gallons/month
<5.6
74
Footnotes from Part A also apply to Part B
*FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART It SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO 0
IF YES, HAVE YOU CONTACTED THE DEMUR REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
Mail an original copy of this DMR including all "No Discharge" reports within 30 days of receipt of the lab results for at end of monitoring period in the case
of "No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, NC 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system
designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who
manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and
belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and
imprisoq#wnt for knowing violations."
re of
1 w
Date
Permit Date: 11/1/2018-05/31/2021 SWU-249, Last Revised 11/5/2018
Page 2 of 2
STORMWATER DISCHARGE MONITORING REPORT
for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG060000
CERTIFICATE OF COVERAGE NO. NCG06 0 0 2 3
FACILITY NAME
COUNTY Union
Farms, Inc.
PERSON COLLECTING SAMPLES Chris Harrington
LABORATORY PAR Labs Lab Cert. # 20
Part A: Stormwater Benchmarks and Monitoring Results
Date submitted 12/19/19
SAMPLE COLLECTION YEAR 2019
SAMPLE PERIOD ❑ Jan -June ❑■ July -Dec
or ❑■ Monthly' (month)
DISCHARGING TO CLASS ❑ORW ❑HQW [-]Trout ❑PNA
❑Zero -flow ❑Water Supply ❑SA
❑Other
FACILITY ACTIVITIES INCLUDE (check all that apply):
i❑ use/process meats 0 use animal fats/byproducts
PLEASE REMEMBER TO SIGN ON THE REVERSE -)
Total event rainfall 20.65 or ❑ No discharge this period'
Outfall No.
Date Sample
Collected, mo/dd/yr
TSS,
mg/L
pH,
Standard units
COD,
mg/L
Oil and Grease,
mg/L
Fecal Coliform,
Colonies per 100 ml
Enterococci,
Colonies per 100 ml
Benchmark
-
100 or 504
Within 6.0-9.0
120
30
5000'
500'
Parameter Code
-
COS30
00400
00340
00S56
31616
61211
007
11/12/19
1382
7.33
601
<5.7
200
N/A
010
11/12/19
63
7.42
117
<6
195
N/A
' Only applies to facilities that use/process meats.
2The total precipitation must be recorded using data from an on -site rain gauge.
3 For sampling periods with no discharge at any outfalls. You must still submit this discharge monitoring report with a checkmark here.
'See General Permit text, Table 1, identifying the especially sensitive receiving water classifications where the more protective benchmark applies.
'Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
Did this facility perform Vehicle Maintenance Activities using more than 55 gallons of new oil per month? ❑■ yes ❑ no (if yes, complete Part B)
Permit Date: 11/1/2018-05/31/2021 SWU-249, Last Revised 11/5/2018
Page 1 of 2
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new motor oil/month.
Outfall No.
Date Sample Collected
(mo/dd/yr)
24-hour rainfall amount,
Z
Inches
New Motor Oil or
Hydraulic Oil Usage
Non -Polar O&G/Total
Petroleum Hydrocarbons
Total Sus ended Solids
p
Benchmarks
-
-
-
15 mg/L
100 mg/L or 50 mg/L°
Parameter Code
-
46529
NCOIL
00552
C0530
009
11/12/19
0.65
101 gallonsimonth
<5.6
74
Footnotes from Part A also apply to Part B
*FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO Q
IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
Mail an original copy of this DMR including all "No Discharge" reports within 30 days of receipt of the lab results (or at end of monitoring period in the case
of "No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, NC 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system
designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who
manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and
belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and
imprisonment for knowing violations."
re of
rq l(
Date
Permit Date: 11/1/2018-05/31/2021 SWU-249, Last Revised 11/5/2018
Page 2 of 2
PAR
PROM PT- AC,, RATE•PEI,a LE
LABORATORIES, INC
t\NV .PARLABS.CO`I
REPORT -.F ANAT SF.S
Attn: RONA.LD BELL
TYSON FOODS-MIGNROE
PO SOX 965
MONROE, NC 28110-0965
PROJECT NAME: NOV 19
DATE: 11/22/19
SAMPLE NUMBER- 13ib13 SAMPLE !D- TYM STOPM ,7
DATE SAMPLED- 11/12/19
DATE RECEIVED- 11/12/19 SAMPLER- RR
TTME FECEIV=.D- i145 DEL-IVE-RED BY- RE
Paae 1 r 3
SAMPPLE MIATRIX- tnn'
TIME SAMPLED- 0910
RECEIVED BY- DJ
TYPE SAMPLE- Grab
AN?.LYS7S
METHOD
DATE
TIME
Sy
RESULT
UNITS
ANALYSIS
FIELD TEMPERATURE
THERM.
11/12/19
0910
RE
16.2
degrees C
SMl 4500H-B
11/12/19
0910
RS
7-33
units
PH VALUE
EPA 410.4
ll/!8/19
0800
CT
601
mg/L
CHEM.OXV. DEMAND
SM 9222 D
11/12./19
1630
RE
200.0
Col/100mLS
FECAL COLIFOP.M
cPP. 1664
11/18/19
0945
CT
< 5.7
mg/L
OIL & GREASE
SOLIDS
SM 2540 D
11/16/19
0820
DJ
1,382
mg/L
TOTAL SUSPE-LADED
LABORATORY
DIRECTOR
2217 Graham Park Drice • Charlotte. NC 25273
Phone: 17041 i8s-S333 • Fat: (704)58S-8335
u�
AR
PQChf PT. G CCU RATE- RE I1G BLE
LABORATORIES, INC
W W WYARLA BS.COAI
Attn: RONA.LD BELL
TYSON FOODS-MONROF.
PO BOY. 905
MONROE: NC 25i10-09b5
PP.OJECT NAME: NOV 19
;/22/19
SAMPLE NUMBER 1 iI,;,; 3AMPi.F. ID- - :i'Ci)k'•i d9
DATE SAMPLED- 11/12/1
DATE RECEIVED- 11/12/19 SAMPLER- Pi -
TIME RECEL'VED- 1145 BY P.
PAge 2 of 3
ANALYSIS
F IELD 7EMYE3r'TUPE
Dii VALUE
CHEM.OXY. DEh1AND
FEOA.I, COLIFORM
OIL 6 C-REASF
TOTAL SUSPENDED SOLIDS
YS 1 S
i'AT. :IME BY
THERM. RE
St-1 1 9 0=400 Re
Epp, 410., iij!Sii9 0-0;) CT
Y. 92.1E D 11i12/i9 103i RE
EPA. 16-54 CT
0 E 020 DJ
LAbORA9DRY DiRECiOR
1217 Graham Park Drier • Charlotie. NC 28273
Phone: (-.04) >88-8333 • Fax: (704)58S-S335
SAMPLE MATRIX WW
TIME SAIPLED 0900
P.ECEIVED BY- DJ
TYPE SAMPLE- Grab
RES'..1:.^ UNITS
1C.7 ciegrees C:
7.94 units
-. mg/L
155.0 col/100mLs
< 5.6 mg/L
74 mg/ L
PAR
PROM PT• A CCU RATE- RELIA8LE
LABORATORIES, INC
W WAN' PARLARS.COM
REPORT OF ANALYSES
Attn: RONALD SELL
TYSON FOODS-MONROE
PO BOX 965
MONROE, NC 28110-0965
PROJECT NAME: NOV 19
DATE: 11/22/19
SAMPLE NUMBER- 137615
SANIPLE ID- TYM STORM #10
SAMPLE MATRIX- WW
DATE SAMPLED- 11/12!19
TIME SAMPLED- 0845
DATE RECEIVED- 11/12/19
SArgPLER- RB
RECEIVED BY- DJ
TIME RECEIVED- 1145
DELIVERED BY- RB
TYPE SAMPLE- Grab
Pace 3 of 3
ANALYSIS
ANALYSIS
METHOD
FATE
TIME
BY
RESULT UNITS
FIELD TEMPERATURE
THERM.
11/12/19
0645
RB
i6.1 degrees C
pH VALUE
SM 4500H-S
1ii12/19
084o
RB
7.42 units
CHEM.OXY.DEMAND
EPA 410.4
11/16/19
0800
CT
117 mg/L
FECAL COLIFO=M
Sm 9222 D
11/12/19
1630
RE
195.0 col/100mLs
OIL 3 GREASE
EPA 1664
11/18/19
0945
CT
< 6.0 mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 C
11/18/19
C820
DJ
63 me/L
LABORATORY DIRECTOR
2217 Graham Park Drive - Charlotte. NC 28273
Phone: (704) 55S-8333 • Fax: (704) 589-8335
PAIR
PROM PT- AC CU RATE• R EL.AB LE
LABORATORIES, INC
W W W.PARLABS.CONI
REPORT OF ANALYSES
Attn: RONALD BELL
TYSON FOODS-14ONF.OE
PO BOX 965
MONROE, NC 281i0-0965
PROJECT NAME: NOV 19
DATE: 11/22/19
SAMPLE NUMBER- 137613 SAMPLE !D- TYM STCFM d7
DATE SAMPLED- 11/12/19
DATE RECEIVED- 11/12/19 SAMPLER- RE
TIME RECEIVED- 1145 DELIVERED BY- RE
Pape 1 o� 3
ANALYSIS
FIELD TEMPERATURE
off VALUE
CHEM.OXY.DEMAND
FECAL COLIFORM
OIL & GREASE
TOTAL SUSPENDED SOLIDS
SAMPLE NIATRIX- WW
TIME SAMPLED- 0910
RECEIVED BY- DJ
TYPE SAMPLE- Grab
ANALYSIS
METHOD DATE TIME BY RESULT UNITS
THERhI.
11/12/19
0910
RB
16.2
degrees C
SM 45009-B
i1/12/19
0910
RE
7.33
units
EPA 410.4
11/18/19
0800
CT
601
mg/L
SM 9222 D
11/12/19
16.30
RE
200.0
coI/100mLs
EPA 1664
11/16/i9
0945
CT
< 5.7
ma/L
SM 2540 D
11/18/19
0820
DJ
1,282
mg/L
LABORATORY DIRECTOR
2217 Graham Park Drive • Charlotte. NC 28173
Phone: (704)588-3333•Fax: (704)588-8335
PAR
PROMPT. OCCUPATE• CEL..81E
LABORATORIES, INC
R'RvW.PARLV BS.CON1
REPORT OF ANALYSES
Attn: RONALD BELL
TYSON FOODS-MONROE
PO BOX 965
MONROE, NC 28110-0955
PROJECT NAME: NOV 19
DATE: ii/22/19
SAMPLE NUMBER- 137614 SAMPLE TD- TYM STORM 09
DATE SAMPLED- 11/12/19
DATE RECEIVED- 11/12/19 SAMPLER- RB
TIME RECEIVED- i145 DELIVERED BY- RB
Page 2 o: 3
ANALYSIS
FIELD TEMPERATURE
off VALUE
CHEM.OXY.DEMAND -
FECAL COLIFORM
OIL & GREASE
TOTAL SUSPENDED SOLIDS
.NALYS I S
METHOD DATE TIME BY
SAMPLE MATRIX- WW
TIME SAMPLED- 0900
RECEIVED BY- DJ
TYPE SAMPLE- Oran
RESULT UNITS
""TERM.
11/12/19
0900
RB
16.7
degrees C
SM 4500H-B
11/12/19
0900
RB
7.94
units
EPA 410.4
11/18/19
0800
CT
54
mg/L
SM 9222 D
ii/i2/i9
1630
RE
165.0
col/100mLs
EPA 1664
11./18/19
09ZS
CT
< 5.6
mg/L
Shi 2540 D
ii/18/19
0820
DJ
74
mg/L
LABORATORY DIRECTOR
2217 Graham Park Drive • Charlotte, NC 28273
Phone: (704) 588-8333 • Fax: (704) 588-8335
PAR
CCU RATE -RE L I ABLE
LABORATORIES, INC
R'Wlv'.PARLAH&COJ1
REPORT OF ANALYSES
Attn: RONALD BELL
TYSON FOODS-MONROE
PO BOX 965
MONROE, NC 28110-0965
PROJECT NAME: NOV 19
DATE: 11/22/19
SAMPLE NUMBER- 137615
SAMPLE ID- TYM STORM t10
SAMPLE MATRIX- WW
DATE SAMPLED- 11/12/19
TIME SAMPLED- 0845
DATE RECEIVED- 11/12/19
SAMPLER- RE
RECEIVED BY- DJ
TIME RECEIVED- 1145
DELIVERED BY- RE
TYPE SAMPLE- Grab
Paae 3 of '_
ANALYSIS
ANALYSIS
METHOD
DATE
TIME
BY
RESULT UNITS
FIELD TEMPERATURE
THERM.
11/12./i9
0845
RE
16.1 degrees C
PH VALUE
SM 4500H-2
11/12/19
0545
RE
7.42 units
CHEM.OXY.DEMAID
EPA 410.4
11/18/19
0800
CT
117 mg/L
FECAL COLIFORN
Shi 9222 D
11/12/19
i630
RE
195.0 C01/100MLs
OIL & GREASE
EPA 1654
11/13/19
0945
CT.
c 6.0 mg/L
TOTAL SUSPENDED SOLIDS
SM 2540 D
11/18/19
0S20
DJ
63 me/L
LABORATORY DIRECTOR
2217 Graham Park Drive • Charlotte. NC 28273
Phone: (704)588-8333 • Fax: (704) 588-8335