Loading...
HomeMy WebLinkAboutNCG030613_MONITORING INFO_20181125V�,SZv STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT N0, w C,% DOC TYPE. ❑ HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ YYYYMMDD l 1i I� HATERS EDGE ENVIRONNIENTAL, LLC ...� _ 1434 CHESTER ROAD • RALEIGH, INC 27608 • PHONE 919.219.5820 November20, 2019 Mr. Joe Edwards, EHS Officer Matcor Metal fabrication 835 Salem Road v� Welcome, North Carolina 27374 Reference: Stormwater Discharge Outfall Qualitative Monitoring Report, Stormwater Discharge Outfall Monitoring Reports �a Matcor Metal fabrication- Year 2- Period 2- July-December-20 FICEI !./Co Welcome, North Carolina NOV a 5id Waters Edge Job No RI 1-47 ` Dear Mr. Edwards: Own�NT'kh , 1.7 Waters Edge Environmental, LLC (Waters Edge) is pleased to provide two copies of the Year 2- Period 2- July -December 2019 forms for the semi-annual site inspections at the Matcor Metal Fabrication facility located in Welcome, North Carolina (see Figures 1 and 2). The past permit has expired in October 2017; however, it is our understanding that Matcor does not have to petition to renew since they are under a General Permit NCG0300000 (Part Ill -Section B- Subpart 91) and want merely to continue under the existing permit. We have completed the Discharge Outfall Qualitative Monitoring Report. Waters Edge also performed the Stormwater sampling and have tilled out the Stormwater Discharge Outfall Monitoring Report (both report included in Appendix A). Laboratory analytical results are documented in Appendix B. Based on these results, we have exceedances for the following: • Outfall001 I . Exceedance for copper which was detected at 0.0154 mg/L versus a benchmark at 0.007 mg/L. 2. Exceedance for zinc which was detected at 0.449 n1g/L versus a benchmark at 0.067 mg/L. • Outfall002 I. Exceedance for copper which was detected at 0.015 mg/L versus a benchmark at 0.007 mg/L. 2. Exceedance for zinc which was detected at 0.255 mg/L versus a benchmark at 0.067 mg/L. Based on the permit conditions, you should conduct a Tier I inspection of the facility. Any action items which will be reviewed and potential deficiencies addressed. The Tier I response should be recorded in the Stormwater Pollution Prevention Plan. Again, as detailed in earlier reports, due to the lowered benchmark thresholds resulting in benchmark exceedances, we previously sampled an upgradient surface water stream on the site (upgradient Lake Drive) as well as two samples collected from the roof drains. Both roof drain Stormwater Discharge Monitoring Report and Tier I Response Year 2- Period 2- .kdy-December 2019 Matcor Metal Fabrication Welcome, NC Page 2 of 2 November 20, 2019 samples exceeded the zinc benchmark level at 0.067 mg/L (Roof-1 at 1.9 mg/L, and Roof-2 at 0.23 mg/L). The background upgradient surface water samples were below the zinc benchmarks. Based on these results, we would conclude the following: • Metals are present in the upgradient surface water sample at the facility. Even though they are below the zinc benchmarks, this metal is still present and can potentially be a constituting factor to the outfall values detected. • Copper and zinc contained in the building materials or downspouts are also contributing to the zinc in the stormwater which would have nothing to do with the industrial activity at the site. While we understand that multiple exceedances from the same Outfall require a Tier 11 response, we believe that the other contributing factors to the exceedances are mitigating factors; therefore, we will continue with our normal sampling frequency. While we will continue to attempt to improve the stormwater quality at the facility, we believe that these type of metals exceedances are largely due to non -industrial sources and can be found in a wide variety of non -industrial settings (e.g. residential or any structures with metal components). If there are any questions, please contact us at prahn a watersedgeenv.com. Sincerely, WATERS EDGE ENVIRONMENTAL, LLC "1� /C� Phillip L. Ralm President cc: NCDEQ Stormwater (two copies) 19-084/PLR FIGURES �•` ` �':i�l/ ���•f rQ\t��''"�—'` -.\\% ;�� 1. � � .-�j('I �J, � �_� r \8$bSemlAq er +�l��--1 +� �_ 'MJ t`J \'�'�-. i`!`I �`\1-_l. Iif/I ` I�_� 1 }Irk. �• \r -,-. 2. r wsJ J• IWI, if F , ` �� \ i ice` r .fit ♦ • `<f % { t n-!if/J ''�``� /�� ! it ' �` -;��q��.785�• rl� �/ �/ � `� �` F s '� •� 1 l_ J 1 �• l � � s S,r ✓ ��t (, r J �t•) .�':' �\ / ,V J /- !�T \_�J__11 t I �i,�'�'l . f.} ✓f(f/ It ? 1,: fl 339'-' ,� 1 ( JJv' ''� /y t 1 �• �1• • ©fl• • • •':.]`.-Y Y i • J-., • ., , ,� ;lV1.e1�/r! .�-,J- /-1 \: S'. -'/./ /�'. �ii V.i �..J .i'� .� •,� �.♦� h•� � :'.��i •`_ ��1`P,�1 �°SC[ � 1'-_`tP i. .,� v � /.� r { � J �'� • I�C p � 1� P 1 � � •11 J I It 1 1 �V F i/3 J t SITE •I � \' '. � — ` � ;`l 1 1 �l� f J/1! /j f I , ( I a • %�+. • � � � )r � _ � � t �� � �/l=t. �ff +�, � f _.� r' .� '' . .' % ,ti /1/ /d � J • • � - � t �� � \ Av r r ('/"- �._=w^ � ^•' L� f / � i ��1 J ��'✓��/`"mil _ !♦r •�`�•.� \` ` �\\•~',! i �`� �. �� lI S� J,µ��.'�i�It� a �\�: tjt �`G7!./ ,. _S�:-i ' �, \j\�`J`'\•��/`__•_Tl` l _ _ `b_f1/%�� � ` L� I_. - "v ��1�1 N' '" / r� J%l��J_l�J��♦ ��l f� \ �; 1 li ,� • + /�U_ i, t� , t1`11--1•��� rl2-f/�1+.`I� :.1 ' /!I i� \"/�.rl - •...•tl f/ /%�J 1 I`�\ 1?\.'. ••_ / ( .� �` `� b. 1�_'-•{ �'� {�� `� ~, �e ,... vi 8 �'3' / —��3p0 jF^.�i •-iri F \ • i 1 �/ .v L\L_ �•�� • lgp� �f�r��� t jj f1�V i�V ! I•�.A=����`�—vL��i. r...=:� `'.". Job,Vo. Topo Ouad Date Title Project Location Map WATERS EDGE ENVIRONMENTAL. LLC RI1-47 Welcome I.192012 File Name Figure • Scale Project Malcor SPPP R11-17.>Is 1 unknown Welcome. North Carolina � s ir77- �F LL tf2 j�� t p ..`1 oGat sin '{`�,16 �x r t } ilk' 4 �>\ -TM t3 t,Io +5t� �-4-��.yJ'♦ 4t \�a � ! RJ[$ xi�.j 4 {� -rM � klr T§" i' � TI 0 fk t1t �t e!Y� ,�\��� � � �NK'#;' u�l sdNs`• s5rrtC ,A �' a {riu 'atchiasin 'o ' , �. � 4 �_ '?c� �j1 W�ui, �y t;� t 1 «;�'�5•.,(��.5:5.�,iY} V. V ��t'y\. ' # � �kTi rty. .a 't` �. _ 3 t�'�+If�eG��' � � vV� ,t4 .mot tt fity JJ;y�' �' ".' r�•'rtti{. it i v V tt IW6 ,t €p', �� t tk Gatti Bz� N•��\ ^ xl * s""yt_+-tt\a'b '� b It I • ® '�ijf.�'�tt i5i["�.,t+ a .�7's y4 ,,� �'i. ^`o Job No forage/Photo Date Tide i RII-17 Davidson Co. GIS 10272011 Site&Surrounding Properties Map WATERS EDGE ENVIRONMENTAL, LLC File Nmne Figlve Scale Project Matmr SPPP RI 147.ds 2 unknown Welcome, North Carolina Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted _11.20.19, CERTIFICATE OF COVERAGE No. N00030613 FACILITY NAME Matcor Metal Fabrication COUNTY Davidson PERSON COLLECTING SAMPLES T. Haynes LABORATORY —Pace— Lab Cert. k _37706_ Comments on sample collection or analysis: None Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2019_ SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ®ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA [-]Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 -) I-1 No dischorae this period?' Non -Polar O&G/ Outfall No. Date Sample 24-hour rainfall Total Suspended Solids pH. Copper Lead Zinc Total Petroleum Total Toxic Organics Collected' amount, Standard units Hydrocarbons (mo/dd/yr) Inches' Benchmarks =__> - - 100 mg/L or 50 mg/L4 6.0 - 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L 001 10/31/19 1.62 9.1 6.8 0.0154 ND 0.449 NA NA 002 10/31/19 1.62 17.7 7.5 0.015 ND 0.255 NA NA a al.e o�...o ..tfell ' Monthly sampling (instead of semi-annual) must begin with the second consecutive oencnmarx exceeadnce lur me bduic a1 —, I.....- .,......... z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. ' See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. ' Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines forthe facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: il/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." —7eo<p►. Eaw 4 PJJS Name (Print name) El'is/�%.fl„�7-en.bce 5"+Aervitr�� Title (Print title)) 9�j�-lC/ //-/9-lcl. nature (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format "<XX ma/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. No discharge this period?' Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Non -polar O&G/TPH by EPA 1664(SGT-HEM) Total Suspended Solids pH Benchmarks =__> - - 15 mg/L 100 mg/L or 50 mg/L* 6.0 — 9.0 SU Footnotes from Part A also apply to this Part B * See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mad an original and one copy of this DMR including all "No Discharge" reports within 30 days of receipt of the lab results (or at end of monitoring period in the case of "No Discharge' reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee) Permit Date: 11/1/2012-10/31/2017 (Date) SWU-245, last revised 10/25/2012 Page 3 of 3 Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit: hltp"//h2o ear stite nc us/su/Forms Documents hnn#miscforms Permit No.: IN I C I G i 0 13 10 10 10 10 I or Certificate of Coverage No.: I N I C I G 10 13 10 16 11 13 I Facility Name: Matcor Metal Fabrication County: Davidson Phone No. 336.731.5742 Inspector: Thomas Haynes Date of Inspection: 10.31.19 Time of Inspection: 10:45 AM Total Event Precipitation (inches) 1.62 Was this a Representative Storm Event? (See information below) ® Yes ❑ No Please checkyour permit to verify if Qualitative Monitoring must be performed during a representative storm event (requirements vary). ................ A "Rc1. prese1. ntaItive Sto1. r11 m Event" is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1 inches has occurred. A sinele storm event may contain up to 10 consecutive hours of no precipitation. By this signature, I certify that this report is accurate and complete to the best of my knowledge: 12, (Signature of Permittee or Designee) Outfall Description: Outfall No. 001/002 Structure (pipe, ditch, etc.) Receiving Stream: Unnamed Tributary of Swearing Creek Describe the industrial activities that occur within the outfall drainage area: Fabrication 2 Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Liaht brown Page 1 of 2 S W U-242-1 12608 3 Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): No odor noted 4 Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: 2O 3 4 5 5 Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where I is no solids and 5 is the surface covered with floating solids: 1 O 3 4 5 6 Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where I is no solids and 5 is extremely muddy: 1 2O 3 4 5 7 Is there any foam in the stormwater discharge? Yes No 8 Is there an oil sheen in the stormwater discharge? Yes 9 Is there evidence of erosion or deposition at the outfall? Yes 111 Other Obvious Indicators of Stormwater Pollution: List and describe Nnna M Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of Pollutant exposure. These conditions warrant further investigation. Page 2 of 2 S W U-242-112608 s aceAnalytical www.parelabs.caln November 12, 2019 Mr. Phil Rahn Waters Edge Environmental 1434 Chester Road Raleigh, NC 27606 RE: Project: Matcor Pace Project No.: 92451841 Pace Analytical Services, LLC 205 East Meadow Road - Suite A Eden, NC 27288 (336)623-8921 Dear Mr. Rahn: Enclosed are the analytical results for sample(s) received by the laboratory on October 31, 2019. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNUNELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, Clayton McCrickard clayton.mccrickard@pacelabs.com (336)623-8921 Project Manager Enclosures �s�Q PcCRF��� TN1 '9gORPtO�`S� REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 11 aceAnalyticala w w,.pacelabs.com Project: Matcor Pace Project No.: 92451841 Asheville Certification IDS 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 Eden Certification IDS 205 East Meadow Road Suite A, Eden, NC 27288 North Carolina Drinking Water Certification #: 37738 11 CERTIFICATIONS North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 Yrgir iaNELAP Certification #: 460222 North Carolina Wastewater Certification #: 633 UrginiaNELAP Certification #: 460025 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 205 East Meadow Road - Suite Eden, NC 27288 (336)623-8921 Page 2 of 11 lace Analytical a wrim.peeelabs.cem Project: Matcor Pace Project No.: 92451841 Lab ID Sample ID 92451841001 Outfal 1001 92451841002 Outfall 002 SAMPLE SUMMARY Matrix Date Collected Date Received Water 10/31/19 10:30 10/31/19 15:28 Water 10/31/19 11:00 10/31/19 15:28 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 205 East Meadow Road - Suite A Eden, INC 27288 (336)623-8921 Page 3 of 11 1551ceAnalyfical' WwmPacelabs.com SAMPLE ANALYTE COUNT Pace Analytical Services, LLC 2135 East Meadow Road - Suite A Eden, NC 27288 (336)623-8921 Project: Pace Project No.: Matcor 92451841 Analytes Lab ID Sample ID Method Analysts Reported Laboratory 92451841001 Outfall 001 SM 2540D-2011 SOB 1 PASI-E EPA 9040C MWF 1 PASI-E EPA 200.7 Rev 4.4 1994 SH1 3 PASI-A 92451841002 Outfall 002 SM 254OD-2011 SOB 1 PASI-E EPA9040C MWF 1 PASI-E i EPA 200.7 Rev 4.4 1994 SH1 3 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 4 of 11 _�aceAnalytical e wwwgacelabs,cum ANALYTICAL RESULTS Project: Matcor l: Pace Project No.: 92451841 Pace Analytical Services, LLC 205 East Meade. Road - Suite A Eden, NC 27288 (336)623-8921 I sample: outtall 001 Lab ID: 92451841001 Collected: 10/31/19 10:30 Received: 10/31/19 15:28 Matrix: Water Report Parameters I Results Units Limit MDL DF Prepared Analyzed CAS No. Qual 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Total Suspended Solids 9.1 mg/L 2.5 2.5 1 11/01/1914:05 ,i 9040 pH Analytical Method: EPA 9040C ;I pH at 25 Degrees C 6.8 Std. Units 0.10 0.10 1 10/31/19 16:54 H3 200.7 MET ICP I I Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Copper 15.4 ug/L 5.0 2.1 1 11/07/1923:15 11/10/19 04:55 7440-50-8 i' Lead ND ug/L 5.0 1.6 1 11/07/1923:15 11/10/1904:55 7439-92-1 Zinc 449 ug/L 10.0 3.9 1 11/0711923:15 11/1011904:55 7440-66-6 Sample: Outfall 002 Lab ID: 92451841002 Collected: 10/31/1911:00 Received: 10/31/19 15:28 Matrix: Water Report Parameters Results Units Limit MDL DF Prepared Analyzed CAS No. Qual 2640D Total Suspended Solids Analytical Method: SM 254OD-2011 i; Total Suspended Solids 17.7 mg/L 2.5 2.5 1 11/01/19 14:05 9040 pH Analytical Method: EPA 9040C pH at 25 Degrees C 7.5 Std. Units 0.10 0.10 1 10/31/19 17:05 H3 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 '.Copper 15.0 ug/L- 5.0 2.1 1 11/07/19 23:15 11/10/1904:59 7440-50-8 Lead ND ug/L 5.0 1.6 1 11/07/1923:15 11/10/1904:59 7439-92-1 Zinc 255 ug/L 10.0 3.9 1 11/07/1923:15 11/10/1904:59 7440-66-6 Date: 11/12/2019 02:25 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, I.I.C. Page 5 of 11 Pace Analytical Services, LLC aceAnalytieal a w Rd Suite A 205 East MeadoEden NC 27268 www.pacelaas.com (336)623-8921 QUALITY CONTROL DATA I I Project: Matcor �. Pace Project No.: 92451841 QC Batch: 506938 Analysis Method: SM 2540D-2011 QC Batch Method: SM 254OD-2011 Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 92451841001, 92451841002 II METHOD BLANK: 2722039 I Matrix: Water 1, Associated Lab Samples: 92451841001, 92451841002 I� Blank Reporting Parameter Units Result Limit MDL Analyzed Qualifiers Total Suspended Solids mg/L ND 2.5 2.5 11/01/19 14:00 LABORATORY CONTROL SAMPLE: ill 2722040 Spike LCS LCS %Rec Parameter Units Conc. Result % Rec Limits Qualifiers Total Suspended Solids mg/L 250 250 100 90-110 I� SAMPLE DUPLICATE: 2722041 92451523001 Dup Max Parameter Units Result Result RPD RPD Qualifiers Total Suspended Solids I I I mg/L ND ND 25 I' SAMPLE DUPLICATE: 2722753 " 92451788001 Dup Max Parameter Units Result Result RPD RPD Qualifiers Total Suspended Solids mg/L ND ND 25 Results presented on this page are in the units Indicated by the "Units" column except where an alternate unit Is presented to the right of the result. REPORT OF LABORATORY ANALYSIS I! This report shall not be reproduced, except in full, Date: 11/12/2019 02:25 PM without the written consent of Pace Analytical Services, LLC. Page 6 of 11 aceAnalytical e www.pacelabs.cam I' I I Project: Matcor Pace Project No.: 92451841 QUALITY CONTROL DATA I QC Batch: 507094 Analysis Method: EPA9040C I I QC Batch Method: EPA 9040C Analysis Description: 9040 pH EDEN Associated Lab Samples: 92451841001, 92451841002 Pace Analytical Services, LLC 205 East Meadow Road - Suite A Eden, NC 27288 (336)623-8921 SAMPLE DUPLICATE: 2722737 92451599001 Cup Max Parameter Units Result Result RPD RPD Qualifiers I pH at 25 Degrees C Std. Units 7.9 7.9 0 9 H3 I. i, Results presented on this page are In the units Indicated by the "Units" column except where an alternate unit is presented to the right of the result. Date: 11/12/2019 02:25 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the wntlen consent of Pace Analytical Services, LLC, Page 7 of 11 I t aPace Analytical I �laceAnalytical 205 EastMe dow RoadLSueto A www.pacelabs.com Eden, NC 27288 (336)623-8921 I QUALITY CONTROL DATA Project: Matcor Pace Project No.: 92451841 QC Batch: 508337 Analysis Method: EPA 200.7 Rev 4.4 1994 OC Batch Method: EPA 200.7 Rev 4.41994 Analysis Description: 200.7 MET Associated Lab Samples: 92451841001, 92451841002 METHOD BLANK: 2728867 Matrix: Water Associated Lab Samples: 92451841001, 92451841002 Blank Reporting Parameter Units Result Limit MDL Analyzed Qualifiers Copper ug/L NO 5.0 2.1 11/11/19 11:55 Lead ug/L NO 5.0 1.6 11/11/19 11:55 . Zinc it ug/L NO 10.0 3.9 11/11/19 11:55 LABORATORY CONTROL SAMPLE: 2728868 Spike LCS LCS % Bee Parameter Units Cone. Result e/ Rec Limits Qualifiers II Copper ug/L 500 485 97 85-115 Lead ug/L 500 463 93 85-115 Zinc it l I ug/L 500 448 90 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2728869 2728870 MS MSD 92451808005 Spike Spike MS MSD MS MSD %Rec Max Parameter Units Result Cone. Conc. Result Result e/ Rae % Rae Limits RPD RPD Qual Copper ug/L 6.0 500 500 509 508 101 100 70-130 0 20 Lead ug/L NO 500 500 485 490 97 98 70-130 1 20 Zinc ug/L 28.6 500 500 508 516 96 97 70-130 2 20 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2728871 2728872 u MS MSD 92452456003 Spike Spike MS MSD MS MSD %Rec Max Parameter Units Result Cone. Conc. Result Result %Rec %Rec Limits RPD RPD Qua[ II Copper ug/L 94.2 500 500 615 610 104 103 70-130 1 20 Lead ug/L 5.0 500 500 502 504 99 100 70-130 0 20 Zinc ug/L it 112 500 500 607 604 99 98 70-130 1 20 I� i Results presented on this rehears In the units indicated by the "units" eolumn except where an alternate unit Is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11/12/2019 02:25 PM without the wntten consent of Pace Analytical Services, -I-C. Page 8 of 11 2acleAnalyficals www.pacelabs.com QUALIFIERS Project: Matcor Pace Project No.: 92451841 DEFINITIONS Pace Analytical Services, LLC 205 East Meadow Road - Suite A Eden, NC 27289 (336)623-9921 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL-Adjusted Method Detection Limit. PQL - Practical Quantitation Limit. RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unfounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES PASI-A Pace Analytical Services - Asheville PASI-E Pace Analytical Services - Eden � ANALYTE QUALIFIERS H3 Sample was received or analysis requested beyond the recognized method holding time REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11/12/2019 02:25 PM without the written consent of Pace Analytical Services, L-C. I I Page 9 of 11 1 � lace Analytical e www.pacalabs.com QUALITY CONTROL DATA CROSS REFERENCE TABLE Pace Analytical Services, LLC 205 East Meadow Road - Suite A Eden, NC 27288 (336)623-8921 Project: Matcor Pace Project No.: 92451841 Analytical Lab ID Sample ID QC Batch Method QC Batch Analytical Method Batch 92451841001 Outfall 001 SM 2540D-2011 506938 92451841002 Outfall 002 SM 2540D-2011 506938 92451841001 Outfall 001 EPA 9040C 507094 92451841002 Outfall 002 EPA 9040C 507094 924511141001 Outfall 001 EPA 200.7 Rev 4.4 1994 508337 EPA 200.7 Rev 4.4 1994 508370 92451841002 Outfall 002 EPA 200.7 Rev 4.4 1994 508337 EPA 200.7 Rev 4.4 1994 508370 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Dale: 11/12/2019 02:25 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 11 CHAIN -OF -CUSTODY Analytical Request Document Chain -of -Custody is a LEGAL DOCUMENT - Complete all releven[ fields Address: Jam/ / pv �, Report To: i%! I/ �/- ��) Email To: �W® V.92451841 ' korder N.ai or. 92451841 ps as as Contain Lab Project Manager:�2yt '•Presevat a Tlpes:(1) ni1rc acid,(2) sulfur., aud, (3) I,dai,hlonc and.(4)s.d,rm hydrous (5) irc avuae, (6) methanol,(7) sodium blsuif ut,{e)sodium thiosulfate,(9)he.ane,(A)ascorbic acid.(A) ammoniumsulfate. (Q ammoniwn hydroxide, (0) TSP, (U) Unpreserved. (0) Other Analyses Lab Profile/Line 'Lab 5 pl Receipt Che klis[- Custody Seats Prt eni/Intai: x, Y '1 TTtT quetociv Signatures dre ent ry9 W co_1C to S.vgaatu e P e9eh� y"I NA .• 3otitles I_tace ..,, .-Y IT RAC =opy To: //. Site Collection Info/Address: _ustomer Project Name)Numbat State: County/City: Time Zone Collected: ( ]PTI IMT[ ]CT [ T r.nr_. Phone: Site/Facility ID 6: Com nce Monitoring? Email I c<yes [ INo Collected By (print) Purchase Order p. OW PWS ID M: Code: Quote il: ��T —, DW Location Cbllee�Y (signa r Turnaround Date. Required: Immetl rely Packed on Ice: 0 • I I No S, pie DispoSal: Rush: Field Filtered (if applicable): I �Dsppse as app5p,ate I I Return ( ]Same Day ] )Next Day [ I Yes ( ) No I I Archive 1120.y [ 1 3 Day I I4Day [ j 5 Day Analysis: (Hold: (Expedite Charges Apply) ` Matrix Codes (Insert in Matrix box below): Drinking Water OW), Ground Water (GW), Wastewater (W W), Product (P), Soil/Solid (SL), Oil (OE), Wipe (WP), Air (AR), Tissue (TS), Bioassay (B), Vapor (V), Other (FIT) Camp/ Collec[ed(ar Composite End Res pof Customer Sample ID Matrix' Grab Composite Start) Cl Ctns Date I Time I Date I Time Customer Remarks/ Special Conditions/Possible Hazards: Type of ice Used: vye't Blue pry None SHORT HOLDS.PRESEtJT (<7Zhours)i X- N N( Packing Material Usedh lab racking M: 3 32654 Samples Feceived via Radchem sample(s) screened(1500apm). Y N N� FEDE% UPS Cl ten Courier , Pace Relinquished by/Company: (Signature) Date/Time: ReceiJed by/Company (Signature) Date%Time: MTl l%'/. ,% Table q: � / v �•� r` .Il.-III r✓1 Acctnum: Relinquished byfCo fiy:(Signature) Date 'me! eceived by/Company:(5igna[ure) Date"Tini Template: / Prelogin: nr Relinquished by/Company: (Signature) Da[e/Ti mReceived by/Company: (Signature) Da[e,'Time: PhtV,+3� — e: 46131 Eo_cect -Bottle. X OdrA Su£Ei a me -S It rA Sampl Recdreod an -cc . -d oa VOA-.Bead'space acceptable. Y IT NA Lana Res fated So 1 I we Smaples in holding T ae -Y N Rcs itival cbloranc Pruucnt Y R J c1;5iv ps. Samp'_ p3 AeecveSble Yta ern .Sull Eidc, Present Y N F.A' ,Lead Acetate Strips: _ `LAA-USE ONLY:. ' Lab -Sample'> / Comments: . Temp Blank Received- Y N ter Therm ID/i�� Cooler i Temp Upon Receipf. C Cooler i Thermtom Factor oC Coale, 1 Corrected Temp: oc Comments: Trip Blank Received .Y N NA HCL MCOH TSP Other Non Coofcrmance(s): Page 1 , ^1%*� WATFRS EDGE ENVIRONMENTAL, LLC Mrz"e 14 1434 CHESTER ROAD • RALEIGH, NC 27608 • PHONE 919.219.6820 November 20, 2019 Mr. Joe Edwards, EHS Officer Matcor Metal Fabrication 835 Salem Road Welcome, North Carolina 27374 Reference: Stormwater Discharge Outfall Qualitative Monitoring Report, Stormwater Discharge Outfall Monitoring Reports Matcor Metal Fabrication- Year 2- Period 2- July-December-2019 Welcome, North Carolina Waters Edge Job No RI 1-47 I Dear Mr. Edwards: Waters Edge Environmental, LLC (Waters Edge) is pleased to provide two copies of the Year 2- Period 2- July -December 2019 forms for the semi-annual site inspections at the Matcor Metal Fabrication facility located in Welcome, North Carolina (see Figures I and 2). The past permit has expired in October 2017; however, it is our understanding that Matcor does not have to petition to renew since they are under a General Permit NCG0300000 (Part I II -Section B- Subpart #1) and want merely to continue under the existing permit. We have completed the Discharge Outfall Qualitative Monitoring Report. Waters Edge also performed the stormwater sampling and have filled out the Stormwater Discharge Outfall Monitoring Report (both report included in Appendix A). Laboratory analytical results are documented in Appendix B. Based on these results, we have exceedances for the following: • Outfall001 I . Exceedance for copper which was detected at 0.0154 mg/L versus a benchmark at 0.007 ing/L. 2. Exceedance for zinc which was detected at 0.449 mg/L versus a benchmark at 0.067 mg/L. • Outfall002 I. Exceedance for copper which was detected at 0.015 mg/L versus a benchmark at 0.007 mg/L. 2. Exceedance for zinc which was detected at 0.255 mg/L versus a benchmark at 0.067 mg/L. Based on the permit conditions, you should conduct a Tier 1 inspection of the facility. Any action items which will be reviewed and potential deficiencies addressed. The Tier I response should be recorded in the Stormwater Pollution Prevention Plan. Again, as detailed in earlier reports, due to the lowered benchmark thresholds resulting in benchmark exceedances, we previously sampled an upgradient surface water stream on the site (upgradient Lake Drive) as well as two samples collected from the roof drains. Both roof drain Stormwater Discharge Monitoring Report and Tier / Response Year 2- Period 2- July -December 2019 Malcor Metal Fabrication Welcome, NC Page 2 of 2 November 20, 2019 samples exceeded the zinc benchmark level at 0.067 mg/L (Roof -I at 1.9 mg/L, and Roof-2 at 0.23 mg/L). The background upgradient surface water samples were below the zinc benchmarks. Based on these results, we would conclude the following: • Metals are present in the upgradient surface water sample at the facility. Even though they are below the zinc benchmarks, this metal is still present and can potentially be a constituting factor to the outfall values detected. Copper and zinc contained in the building materials or downspouts are also contributing to the zinc in the stormwater which would have nothing to do with the industrial activity at the site. While we understand that multiple exceedances from the same Outfall require a Tier II response, we believe that the other contributing factors to the exceedances are mitigating factors; therefore, we will continue with our normal sampling frequency. While we will continue to attempt to improve the stormwater quality at the facility, we believe that these type of metals exceedances are largely due to non -industrial sources and can be found in a wide variety of non -industrial settings (e.g. residential or any structures with metal components). If there are any questions, please contact us at prahn a watersedeeenv.com. Sincerely, WATERS EDGE ENVIRONMENTAL, LLC Phillip L. Rahn President cc: NCDEQ Stormwater (two copies) 19-084/PLR A �J; 5 4 W"O I E ty 3 PF ct; k, r J I X 8P L Pr J d A. Job Ao. Topo Quad Dwe Title Project Location Map �TERSEDGE ENVIRONNIMENTAL, LLC RI 1-47 Welcome 1 19 2012 1 IFile No,,,e Figu,, Scale Project Matcor SPPP RI I I I Welcome. North Carolina I Job No. /n ageiYnoro care r11e Site & Surrounding Properties Map t RII-17 Davidson Co. GIS 10.27.2011 WATERS EDGE ENVIRON\4ENTAL, LLC ram- File Name Figure Scale Project Malwr $PPP RI 1-47 xis 2 unknown Welcome, North Carolina APPENDIX A Semi-annual Stormwater Discharge Monitoring Report for North Carolina Division of Water Quality General Permit No. NCG030000 Date submitted 11.20.19 CERTIFICATE OF COVERAGE NO. N00030613 FACILITY NAME _Matcor Metal Fabrication COUNTY Davidson PERSON COLLECTING SAMPLES T. Haynes LABORATORY —Pace— Lab Cert. # _37706_ Comments on sample collection or analysis: None Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR _2019_ SAMPLE PERIOD ❑ Jan -June ® July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ®ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑Water Supply ❑SA ❑Other PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4 ❑ No discharge this periodj2 Outfall No. Date Sample Collected' imo/dd/yri 24-hour rainfall amount, Inches' Total Suspended Solids pH Standard units Copper Lead Zinc on -Polar leum Total Petro Hydrocarbons Total Toxic Organics s Benchmarks =__> - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.007 mg/L 0.03 mg/L 0.067 mg/L 15 mg/L 1 mg/L .001 10/31/19 1.62 9.1 6.8 0.0154 ND 0.449 NA NA 002 10/31/19 1.62 17.7 7.S 0.015 NO 0.255 NA NA ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same ouudn. Z For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 3The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. See General Permit, Table 3 identifying the especially sensitive receiving water classifications where the more protective benchmark applies. ' Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 1 of 3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." �eac�o� E�w,af�S Name (Print name) Title (Print title) a nature (Date) Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. n No discharge this period?2 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 Non -polar O&G/TPH by EPA 1664 (SGT-HEM) Total Suspended Solids pH Benchmarks =__> - - 15 mg/L 100 mg/L or 50 mg/L' 6.0 - 9.0 SU Footnotes from Part A also apply to this Part B See General Permit text, Table 5, identifying the especially sensitive receiving water classifications where the more protective benchmark applies. Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 2 of 3 Note: if you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANYONE OUTFALL? YES ❑ NO ❑ IF YES, HAVE YOU CONTACTED THE DWQ REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an original and one copy of this_DMR including all "No Discharge" reports within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." of Permittee) (Date) Permit Date: 11/1/2012-10/31/2017 SWU-245, last revised 10/25/2012 Page 3 of 3 Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report For guidance on filling out this form, please visit: littp'//li2o.eiir.state.tic.us/sti/ForiTis Documents.1u n#miscforms Permit No.: I N I C I G 10 13 10 10 10 10 I or Certificate of Coverage No.: I N I C I G 10 13 10 16 11 13 Facility Name: Matcor Metal Fabrication County: Davidson Phone No. 336.731.5742 Inspector: Thomas Haynes Date of Inspection: 10.31.11 Time of Inspection: 10:45 AM 'total Event Precipitation (inches): 1.62 Was this a Representative Storm Event? (See information below) ® Yes ❑ No Please check your permit to verify if Qualitative Monitoring in ust be performed during a representative storm event (requirements vary). A "Representative Storm Event' is a storm event that measures greater than 0.1 inches of rainfall and that is preceded by at least 72 hours (3 days) in which no storm event measuring greater than 0.1 inches has occurred. A single storm event may contain up to 10 consecutive hours of no precipitation. Lay this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) I Outfall Description: Outfall No. 001/002 Structure (pipe, ditch, etc.) Pipe Receiving Stream: Unnamed Tributary of Swearing Creek Describe the industrial activities that occur within the outfall drainage area: Metal Fabrication 2 Color: Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: Lioht brown Page 1 of 2 S W U-242- 112608 3 Odor: Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.): No odor noted 4 Clarity: Choose the number which best describes the clarity of the discharge, where I is clear and 5 is very cloudy: 1 (D 3 4 5 5 Floating Solids: Choose the number which best describes the amount of floating solids in the stormwater discharge, where 1 is no solids and 5 is the surface covered with floating solids: 1 O 3 4 5 6 Suspended Solids: Choose the number which best describes the amount of suspended solids in the stormwater discharge, where 1 is no solids and 5 is extremely muddy: 1 O 3 4 5 7 Is there any foam in the stormwater discharge? Yes No 8 Is there an oil sheen in the stormwater discharge? Yes No 9 Is there evidence of erosion or deposition at the outfall? Yes No 10 Other Obvious Indicators of stormwater Pollution: List and describe Note: Low clarity, high solids, and/or the presence of foam, oil sheen, or erosion/deposition may be indicative of pollutant exposure. These conditions warrant further investigation. Page 2 of 2 S W U-242-1 12608 APPENDIX B Ar ace Analytical a www.pacelabs.cori November 12, 2019 j Mr. Phil Rahn Waters Edge Environmental 1434 Chester Road Raleigh, NC 27606 RE: Project: Matcor Pace Project No.: 92451841 Pace Analytical Services, LLC 205 East Meadow Road -Suite A Eden, NC 27288 (336)623-8921 Dear Mr. Rahn: Enclosed are the analytical results for sample(s) received by the laboratory on October 31, 2019. The results relate only to the samples included in this report. Results reported herein conform to the most current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where applicable, unless otherwise noted in the body of the report. If you have any questions concerning this report, please feel free to contact me. Sincerely, 1�47� W_C__r�z Clayton McCrickard clayton.mccrickard@pacelabs.com (336)623-8921 Project Manager Enclosures �e PCCRpa � TNK \9B�RptpPi REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 1 of 11 aceAnalytical e www.Dacelabmom Project: Matcor I, Pace Project No.: 92451841 Pace Analytical Services, LLC 205 East Meadow Road - Suite Eden, NC 27288 (336)623-8921 Asheville Certification IDs 2225 Riverside Drive, Asheville, NC 28804 FloridalNELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 CERTIFICATIONS North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 vrginiaA/ELAP Certification #: 460222 �IEden Certification IDs 205 East Meadow Road Suite A, Eden, NC 27288 North Carolina Wastewater Certification #: 633 North Carolina Drinking Water Certification #: 37738 UrginiaNELAP Certification #: 460025 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, I.I.C. Page 2 of 11 �PaceAnalXical e www.pacelaba.com SAMPLE SUMMARY Project: Matcor Pace Project No.: 92451841 Lab ID Sample ID Matrix Date Collected Date Received . 92451841001 92451841002 Outfall 001 Outfall 002 Water Water 10/31/1910:30 10/31/1911:00 10/31/1915:28 10/31/1915:28 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Pace Analytical Services, LLC 205 East Meadow Road - Suite A Eden, NC 27288 (336)623-8921 Page 3 of 11 i laceAnalyfical" www.pacelabs.cam SAMPLE ANALYTE COUNT Project: Matcor Pace Project No.: 92451841 Pace Analytical Services, LLC 205 East Meadow Road - Suite A Eden, NC 27288 (336)623-8921 r Lab ID Sample ID Method Analysts Analytes Reported Laboratory 92451841001 Outfall 001 SM 254OD-2011 SOB 1 PASI-E EPA 9040C MWF 1 PASI-E EPA 200.7 Rev 4.4 1994 SH1 3 PASI-A 92451841002 Outfall 002 SM 2540D-2011 SOB 1 PASI-E EPA 9040C MWF 1 PASI-E EPA 200.7 Rev 4.4 1994 SH1 3 PASI-A REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 4 of 11 II' Pace Analytical Services, LLC s aceAnalytical 205 East Meadow Road - Suite A Eden, NC 27288 wwminicelabs.cort (336)623-8921 ANALYTICAL RESULTS l Project: Matcor Pace Project No.: 92451841 Sample: Outfall 001 Lab ID: 92451841001 Collected: 10131/1910:30 Received: 10131/1915:28 Matrix: Water Report Parameters Results Units Limit MDL DF Prepared Analyzed CAS No. Qual 2540D Total Suspended Solids Analytical Method: SM 254OD-2011 Total Suspended Solids 9.1 mg/L 2.5 2.5 1 11/01/19 14:05 9040 pH Analytical Method: EPA 9040C pH at 25 Degrees C 6.8 Std. Units 0.10 0.10 1 10/31/19 16:54 H3 1200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 Copper 15.4 ug/L 5.0 2.1 1 11/07/19 23:15 11/10/19 04:55 7440-50-8 Lead ND ug/L 5.0 1.6 1 11/07/19 23:15 11/1011904:55 7439-92-1 Zinc I' 449 ug/L 10.0 3.9 1 11/07/19 23:15 11/10/19 04:55 7440-66-6 Sample: Outfall002 Lab ID: 92451841002 Collected: 10/31/1911:00 Received: 10/31/1915:28 Matrix: Water Report Parameters Results Units Limit MDL DF Prepared Analyzed CAS No. Qual 2540D Total Suspended Solids Analytical Method: SM 2540D-2011 Total Suspended Solids 17.7 mg/L , 2.5 2.5 1 11/01/19 14:05 9040 pH Analytical Method: EPA 9040C pH at 25 Degrees C 7.5 Std. Units 0.10 0.10 1 10/31/19 17:05 H3 200.7 MET ICP Analytical Method: EPA 200.7 Rev 4.4 1994 Preparation Method: EPA 200.7 Rev 4.4 1994 ,Copper 15.0 ug/L 5.0 2.1 1 11/0711923:15 11/10/19 04:59 7440-50-8 Lead ND ug/L 5.0 1.6 1 11/07/19 23:15 11/10/19 04:59 7439-92-1 Zinc 255 ug/L 10.0 3.9 1 11/07/19 23:15 11/10/19 04:59 7440-66-6 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Dale: 11/12/2019 02:25 PM without the written consent of Pace Analytical Services, L-C. Page 5 of 11 Pace Analytical Services, LLC a �aceAnalytical 205 East Meadow -Suite A Eden,Roa en, NC 27288 wune pacelabs.co n (336)623-8921 QUALITY CONTROL DATA 'Project: Malcor ,,Pace Project No.: 92451841 QC Batch: 506938 Analysis Method: SM 254OD-2011 QC Batch Method: SM 2540D-2011 Analysis Description: 2540D Total Suspended Solids Associated Lab Samples: 92451841001, 92451841002 METHOD BLANK: 2722039 Matrix: Water 'Associated Lab Samples: 92451841001. 92451841002 Blank Reporting Parameter Units Result Limit MDL Analyzed Qualifiers Total Suspended Solids mg/L ND 2.5 2.5 11/01/19 14:00 LABORATORY CONTROL SAMPLE: 2722040 Spike LCS LCS % Rec Parameter Units Conc. Result %Rec Limits Qualifiers Total Suspended Solids mg/L 250 250 100 90-110 'SAMPLE DUPLICATE: 2722041 92451523001 Dup Max Parameter Units Result Result RPD RPD Qualifiers Total Suspended Solids mg/L NO NO 25 SAMPLE DUPLICATE: 2722753 92451788001 Dup Max Parameter Units Result Result RPD RPD Qualifiers ,Total Suspended Solids mg/L NO NO 25 Results presented on this page are lathe units Indicated by the "Units' column except where an alternate unit Is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11/12/2019 02:25 PM without the written consent of Pace Analytical Services, L-C. Page 6 of 11 t aceAnalytical a www.pacelabs.com I Project: Matcor Pace Project No.: 92451841 QC Batch: 507094 'QC Batch Method: EPA 9040C Associated Lab Samples: 92451841001, 92451841002 „SAMPLE DUPLICATE: 2722737 �Parameter Units I pH at 25 Degrees C Ste. Units QUALITY CONTROL DATA Analysis Method: EPA 9040C Analysis Description: 9040 pH EDEN 92451599001 Dup Result Result RPD 7.9 7.9 0 Max RPD Pace Analytical Services, LLC 205 East Meadow Road -Suite A Eden, NC 27288 (336)623-8921 Qualifiers 9 H3 Results presented on this page are in the units Indicated by the "Units" column except where an alternate unit Is presented to the right of the result. Date: 11 /12/2019 02:25 PM REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, LLC. Page 7 of 11 laceAnalyfical" Pace Analytical Services, LLC 205 East Meadow Road Eden, NCC 272 2728B www.pacelabs.com (336)623-8921 QUALITY CONTROL DATA Project: Matcor Pace Project No.: 92451841 QC Batch: 508337 Analysis Method: EPA 200.7 Rev 4.4 1994 OC Batch Method: EPA 200.7 Rev 4.4 1994 Analysis Description: 200.7 MET .'Associated Lab Samples: 92451841001. 92451841002 METHOD BLANK: 2728867 Matrix: Water Associated Lab Samples: 92451841001, 92451841002 Blank Reporting Parameter Units Result Limit MOIL Analyzed Qualifiers Copper ug/L ND 5.0 2A 11/11/1911:55 ' Lead ug/L ND 5.0 1.6 11/11/19 11:55 Zinc ug/L NO 10.0 3.9 11/11/1911:55 LABORATORY CONTROL SAMPLE: 2728868 Spike LCS LCS %Rec Parameter Units Cone. Result % Rec Limits Qualifiers 'Copper ug/L 500 485 97 85-115 Lead ug/L 500 463 93 85-115 Zinc ug/L 500 448 90 85-115 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2728869 2728870 MS MSD 92451808005 Spike Spike MS MSD MS MSD % Rec Max Parameter Units Result Cone. Cone. Result Result %Rec e/ Rec Limits RPD RPD Qual Copper ug/L 6.0 500 500 509 508 101 100 70-130 0 20 Lead ug/L NO 500 500 485 490 97 98 70-130 1 20 Zinc ug/L 28.6 500 500 508 516 96 97 70-130 2 20 MATRIX SPIKE & MATRIX SPIKE DUPLICATE: 2728871 2728872 MS MOD 92452456003 Spike Spike MS MSD MS MSD e/ Rec Max Parameter Units Result Cone, Cone. Result Result %Rec %Rec Limits RPD RPD Qua] Copper ug/L 94.2 500 500 615 610 104 103 70-130 1 20 Lead ug/L 5.0 500 500 502 504 99 100 70-130 0 20 Zinc ug/L 112 500 500 607 604 99 98 70-130 1 20 Results presented on this page arc In the units indicated by the' Units" column except where an alternate on It Is presented to the right of the result. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11/12/2019 02:25 PM without the written consent of Pace Analytical Services, L-C. Page 8 of 11 laceAnalyficala w 'Pacelabs.cam QUALIFIERS Project: Matcor " Pace Project No.: 92451841 DEFINITIONS Pace Analytical Services, LLC 205 East Meadow Road - Suite A Eden, NC 27288 (336)623-8921 DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot. ND - Not Detected at or above adjusted reporting limit. TNTC - Too Numerous To Count J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit. MDL- Adjusted Method Detection Limit. PQL- Practical Quantitation Limit. '! RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and bias for a specific analyte in a specific matrix. S - Surrogate 1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is a combined concentration. Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values. LCS(D) - Laboratory Control Sample (Duplicate) MS(D) - Matrix Spike (Duplicate) DUP - Sample Duplicate RPD - Relative Percent Difference NC - Not Calculable. SG - Silica Gel - Clean -Up U - Indicates the compound was analyzed for, but not detected. Acid preservation may not be appropriate for 2 Chloroethylvinyl ether. „ A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonilrile by EPA Method 8260. N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for each analyte is a combined concentration. Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes. TNI - The NELAC Institute. LABORATORIES PASI-A Pace Analytical Services - Asheville PASI-E Pace Analytical Services - Eden ANALYTE QUALIFIERS H3 Sample was received or analysis requested beyond the recognized method holding time. REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Date: 11/12/2019 02:25 PM without the written consent of Pace Analytical Services, LLC, Page 9 of 11 aceAnalytical www.pac ilabs.com QUALITY CONTROL DATA CROSS REFERENCE TABLE Project: Matcor Pace Project No.: 92451841 Pace Analytical Services, LLC 205 East Meadow Road - Suite A Eden, NC 27288 (336)623-8921 Lab ID Sample ID QC Batch Method QC Batch Analytical Method Analytical Batch 92451841001 Outfall 001 SM 25400-2011 506938 92451841002 Outfall 002 SM 254OD-2011 506938 ,92451841001 Outfall 001 EPA 9040C 507094 192451841002 Outfall 002 EPA9040C 507094 92451841001 Outfall 001 EPA 200.7 Rev 4.4 1994 508337 EPA 200.7 Rev 4.4 1994 508370 92451841002 Outfall 002 EPA 200.7 Rev 4.4 1994 508337 EPA 200.7 Rev 4.4 1994 508370 REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, Dale: 11/12/2019 02:25 PM without the written consent of Pace Analytical Services, LLC. Page 10 of 11 WO# • 9245d841 Number or �korder II � III III I I II I III'( III 92451842 JNLY a F-CUSTODY Analytical Request Document �� CHAIN-OF-CUSTODY ! -Face Analytical' Chain -of -Custody is a LEGAL DOCUMENT - Complete all relevent fields Company: ) Billing Information: Address: - Container Preservative T e "' lab Project ManaGer: Rz�srs1+l Report To: n `y� Email To: ••preservative Types: (1)runic acid.(2)sulfuric acid,(3) hydrochloric acid. (4)s.drum hydroxide.(5) arc acclat,, (61 meth ... 1.(7)sodium bisulfaw, (E) sodium thmsulfau,(91 hexane.(A) ascorbic acid, lB) ammoniumsulime, (C) ammonium hydroxide,(0) TSP, (U) Unpr,,read.(0) Other Copy To: Site Collection Info/Address: Analyses JlLab Profile/Line: Customer Project Name/N/umber. r� _ !�/ �� / State: County/City: Time Zone Collected: 1.� / / ..� LnI I PT ( 1 MT I I CT [ r ,( �°' i/'_ \ 1. I ^ \-„ \ N r /- � Lab Sample Receipt checklist: ' Custody Scal: P[c.ent/Intact Y N.t Custody Signatures PrescacY !.' Collector Signature Precool �' tl NA Bottle. Intact X[i NA correct Bottles x u tit: Sufficient Volume Y-n NA Ramp L_s Received c YN NF VOA - Beadspace Acceptable Y II Nr' USDA Ne9ulaced 9o111 y V Rrc Samples in Holding Time .: N NA Residual chlorine Pres1nc y R )kC Cl scups: Sample px Acceptable C,� ,YN NA pH Scrips: 7Je'L( SUlficc P[Csent Y Il SAP Lead Acetate scrips: cAA c5e ONLY: Lab Sample N { Comments: Phone: Email: Site/Facility ID n: COm ante MonitorinN? I Yes [ I No Collected By (print): /lS , Ai Y� Purchase Order fF /A' nU0[C p: �l%r—�/ DW PWS 10 n: DW Location Cod¢: Collected y (sgna ur Turnaround Date Required: in ad toy Pace On Ice: I es I ]NO $ ale Dispofal: k),01sposcasapp5ale ( l Return I Archive: ]Hold: Rush: [ ] Same Day I I Next Day I ]? Day I 13 Day I 14 Day I 15 Day (Expedite Charges Apply) Field Filtered (if applicable): f I Yes j ]NO Analysis: 'Matrix Codes (Insert'in Matrix box below): Drinking Water(DW), Ground Water(GW), Wastewater(WW), Product (P), Soil/Solid (SL), Oil (OIL), Wipe (WP), Air (AR), Tissue (TS), Bioassay (B), Vapor (V), Other (OT) Customer Sample ID Matrix' Comp/ Grab Collected (Or Composite Start) Composite End Res Cl not Cins Date Time Dare Time ( ,6 id-ir io3v ti ✓ y / ./ Customer Remarks / Special Conditions / Possible Hazards: TYPe of Ice Used: bV6 Blue Dry None SHORT HOLDS PRESENT (02 hours)'. .1' N. N/A Lab Sample Temperature Info: Temp Blank Rece ved: Y N N'� Therm ID# �I �. I. n< Cooler 1 Temp Upon ReceiptiNOC Cooler 1 Therm Corr. Factor. �' OC Coolers Corrected Temp: oC Comments: Packing Material Used: Wb.Tracking H: ^ tl C 4 Radchem sample(s) screened (<500 cpm): Y N' NA` - Samples received via: FEDEX UFS Client Courier Pare Courser Relinquished by/Company: (Signature) Date/ITime: 'jG /. �� ��xi.7 Received by/Com?any: (Signature)/ j\� Vf✓V �%l�kk! Dare/Time: j `/ 1f. 17 111`I �.)+�Y MT1L LAB USE ONLY Table A: -. Accmum: Rbinquished by/'o y:(Signature) D e/➢Ime: Z Received by/Company:(Signature) Date/Time:') Template: Prelogin: Trip Blank Received: Y N NA HCL M¢OH TSP Other Relinquished by/Company: (Signature) Date/Time Received by/Company:(Signature) _ _ _ . Date,Time: - _ _ - — PB: �� i��.J i[. - -- Non Conformance(s)C-Pace: YES / NO of: %