Loading...
HomeMy WebLinkAboutNCG030541_MONITORING INFO_20191212STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. w C& DOC TYPE. ❑ HISTORICAL FILE E�MONITORING REPORTS DOC DATE ❑ a �� l �a- - YYYYMMDD CREE = wol p ed. F,'December 9, 2019 I; Division of Water Quality Attn: DWQ Central Files n 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Certified Mail - #7015 1520 0001 1084 9671 DEC 12 2019 ¢, i RAL FILES �WR SECTION RE: Stormwater Discharge Outfall (SDO) Monitoring Report Cree, Inc., 3028 Cornwallis Road, Durham, Durham County, North Carolina General Stormwater Permit No. NCG030000/COC NO. NCG030541 July -December 2019, WOLF #1, #2, #3, #4, and #5 I To Whom It May Concern: Please find enclosed the semi-annual stormwater Discharge Monitoring Reports for the five stormwater outfalls located at Cree, Inc., 3028 Cornwallis Road, Durham, North Carolina. The analytical report was received from the laboratory on November 27, 2019. Pace Analytical Services (NC Certification #40, 633, 67) conducted the analyses which completes the second 2019 semi-annual testing requirements for the Cornwallis Road site. Discharge samples were collected at outfalls: #1, #2, and #4. Outfall #3 and #5 had NO DISCHARGE. For the sampled outfalls, and as in previous reports submitted to DEQ, levels for copper and zinc are above the benchmark values listed in Table 3 of section II.B of our stormwater permit for outfalls #1 and #4 (Cu and Zn). In September 2014, Cree was granted an exemption from the requirement to continue following Tier Two and Tier Three response actions as stated in Section B of the stormwater permit for these parameters. Cree will continue to monitor these levels throughout the next semi-annual testing period and report any success in eliminating the elevated levels. In addition, the values for pH reported below benchmark levels at outfalls #1, #2, and #5 during the spring sampling event have returned to the appropriate range. i, Please contact me at 919-407-6101 if you need additional information. i Sincerely, �U�h obin Housh Environmental Manager 4600 Silicon Drive Durham, NC 27703 USA Main: (919) 313-5300 I Stormwater Discharge Monitoring Report for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000 Date submitted 12/9/2019 CERTIFICATE OF COVERAGE NO. NCG03 0 5 4 1 FACILITY NAME Cree RTP COUNTY Durham PERSON COLLECTING SAMPLES Jane Cooper LABORATORY Pace Analytical Lab Cert. # 633 and 40 Comments on sample collection or analysis: No discharge at outfalls #3 and #5.- Part A: Stormwater Benchmarks and Monitoring Results SAMPLE COLLECTION YEAR 2019 SAMPLE PERIOD ❑ Jan -June E] July -Dec or ❑ Monthly' (month) DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA ❑Zero -flow ❑■ Water Supply ❑SA ❑Other NSW, WS-v PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 --) n No dischome this period?z Outfall No. .Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches; Total Suspended Solids PH Standard units Total Copper Total Lead Total Zinc Non -Polar 0&G/ Total Petroleum Hydrocarbons Total Toxic Orgamcss Benchmarks - - 100 mg/L or 50 mg/L4 6.0 — 9.0 0.010 mg/L 0.075 mg/L 0.126 mg/L 15 mg/L 1 mg/L Parameter Code - 46529 C0530 00400 01119 01051 01094 00552 78141 WOLF-1 11/18/2019 0.2 4.8 7.2 0.024 <0.005 0.151 <5.0 NA WOLF-2 11/18/2019 0.2 7.0 7.1 0.009 <0.005 0.027 <5.0 NA WOLF-3 11/18/2019 0.2 No discharge NA NA NA NA NA NA WOLF-4 11/18/2019 0.2 7.1 7.3 0.013 <0.005 0.289 <5.0 NA WOLF-5 11/18/2019 0.2 No discharge . NA - NA NA NA NA NA ' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall. ' For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here. 'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement. "See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies. s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray tube manufacture use the definition found in 40 CFR 469.31). Permit Date: il/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 ----------- --s_—--Page 1of3 Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement: "Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics (TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the solvent management plan included in the Stormwater Pollution Prevention Plan." Robin Housh Name (Print name) Environmental Manager ZTIe (Print jitle) -� /1 1 Aw� IkA_1269 i9 gnature Date Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical format. When results are below the applicable limits, they must be reported in the format. "<XX me/L" where XX is the numerical value of the detection limit, reporting limit, etc. in mg/L. Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month. n Nn dicrhnrnp this nprinrl72 Outfall No. Date Sample Collected' (mo/dd/yr) 24-hour rainfall amount, Inches3 New Motor Oil or Hydraulic Oil Usage Non -Polar O&G/ Total Petroleum Hydrocarbons Total Suspended Solids Benchmarks - - - 15 mg/L 100 mg/L or 50 mg/L4 Parameter Code - 46529 NCOIL 00552 CO530 Footnotes from Part A also apply to Part B Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text. Permit Date: 11/1/2018-OS/31/2021 SWU-245, last revised 11/1/2018 Page 2 of 3 FOR PART A AND PART B MONITORING RESULTS: • A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B. • 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B. • TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO 0 IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑ NO ❑ REGIONAL OFFICE CONTACT NAME: Mail an oriainal copv of this DMR, including all "No Discharge" reports within 30 days of receipt of the lab results for at end of monitoring period in the case of "No Discharge" reports) to: Division of Water Quality Attn: DWQ Central Files 1617 Mail Service Center ' Raleigh, North Carolina 27699-1617 YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED: "I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations." Date Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018 —. —.-- --- --I ---- ---- -- - - -Page 3 of 3—- — — -- --