HomeMy WebLinkAboutNCG030373_MONITORING INFO_20190819�(W
STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO.
DOC TYPE.
❑ HISTORICAL FILE
Lq-MONITORING REPORTS
DOC DATE
❑ LEI � o ti I
YYYYMMDD
REVISED SEMI-ANNUAL STORMWATER DISCHARGE MONITORING REPORT
THIS REPORT REFLECTS CHANGED ANALYSIS RESULTS SUBMITTED 7-22-2019. THE ATTACHED
CERTIFICATE OF ANALYSIS RESULTS INCLUDED IN 7-22-2019 SUBMITTED REPORT AS WELL AS THOSE
IN THE8-12-2019 SUBMITTED REPORT. PLEASE USE THIS, 8-12-2019 SUBMITTED REPORT,
TO REPLACE 7-22-2019 REPORT.
THANKS,
WAYNr
LOR
RECEIVED
AUG 19 2019
CENTRAL FILES
DWR SECTION
�VMICROBA.Ca
Microbac Laboratories, Inc.,; Fayetteville
,. .
CERTIFICATE OF ANALYSIS
K9F0164
Miller Control & Mfg. Co. Project Name: Stormwater sample - Biannual
Mr. Wayne Naylor Project / PO Number: N/A
Post Office Box 1065 Received: 06/12/2019
Clinton, NC 28329 Reported: 07/26/2019
Case Narrative
Field pH (by client): 7.4
-Client requested a lower detection limit for the C000er samole. Sample re -run with method 200.8
Analytical Testing Parameters
Client Sample ID: Stormwater, grab
Sample Matrix: Aqueous Collected By: Naylor
Lab Sample ID: K9F0164-01 Collection Date: 06/09/2019 17:30
Wet Chemistry Result RL Units Dilution Note Prepared Analyzed Analyst
EPA 1664 Rev. B
Oil & Grease (SGT-HEM)
SM 2540 D-2011
Total Suspended Solids
Metals
Metals Aqueous/EPA 200.7 Rev 4.41994
Copper
Lead
Zinc
<5.00
5.00
mg/L 1
06/21/19 0943
TAB
11.2
5.00
mg/L 1
06/14/19 1110
CLB
Result
RL
Units Dilution Note
Prepared
Analyzed
Analyst
C:::)
40.050
0,050
mg/L [� 1
06/20/19 1355
06/20/19 1355
TAB
<0.010
0.010
mg/L 1
06/20/19 1355
06/20/19 1355
TAB
0.049
0.005
mg/L 1
06/20/19 1355
06/20/19 1355
TAB
Client Sample ID: Stonnwater, rerun
Sample Matrix: Aqueous Collected By: Naylor
Lab Sample ID: K9F0164-02 Collection Date: 06/09/2019 17:30
Analvses Subcontracted to: Microbac Laboratories Inc.. - Marietta. OH
Total Metals - ICPIMS
EPA 200.8, Rv. 5.4
G—] Copper
Result
RL
Units
Dilution Note
Prepared
Analyzed
Analyst
1.._J 0.004
0.002
mg/L
1
07/24/19 0631
07/25/19 1721
JYH G
Definitions
MDL: Minimum Detection Limit
RL: Reporting Limit
Project Requested Certification(s) c _
Microbac Laboratories, Inc. - Fayetteville p -
11 North Carolina DENR NPDES • -
Microbac Laboratories, Inc.
2592.Hope Mills:Rd I Fayetteville, NC 28306 1910.8".1920 p I y w".microbac.com Page 1 Of 3
i(DMICROBAC-
IViicrobac Laboratories, Inc. - Fayetteville
CERTIFICATE OF ANALYSIS
K9F0164
Report Comments
Samples were received in proper condition and the reported results conform to
applicable accreditation standard unless otherwise -noted.
The data and information on this, and other accompanying documents, represents
only the sample(s) analyzed. This report is incomplete unless all pages indicated
in the footnote are present and an authorized signature is included.
Reviewed and Approved By:
,::?2IGCL �/UfiL6L2_ft.L
Jeanne Overstreet
Client Relationship Specialist, Environmental
Reported: 07/26/2019 12:03
Microbac Laboratories, Inc.
2592 Hope Mills Rd I Fayetteville, NC 28306 1 910.864.1920 p I www.microbac.com Page 2 of 3
Stormwater Discharge Monitoring Report
for North'Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000
Date submitted
CERTIFICATE OF COVERAGE NO. NCG03U
FACILITY _NAMWL1-L!F_r,^ <owT✓cl-�
COUNTY 1*c ,r,Y J
PERSON COLLE ING SAMPLES0,ai � Yy+� CV'
LABORATORY (rr 0054e— Lab Cert. N /
Comments on sample collection or analysi3,
r° r.:Y.14L= r\, T,% .I'KI
.Id. V64.LLe� " `0.'�10
Part A: Stormwater Bench Par Is and Monitorinj Results
SAMPLE COLLECTION YEAR ;? C( 9
SAMPLE PERIOD ® Jan -June ❑ July -Dec
or ❑ Monthly' (month)
DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
❑Zero -flow ❑Water Supply [:]SA
Other <Lu4SS C ' S L6
PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 4
❑ No discharge this, period7'
Outfall No. '
Date Sample
Collected'
mo dd r
24-hour rainfall
amount,
s:
"' '
Total Suspended Solids
_.�j,,.
pH;
Standard units
Total Copper
Total Lead
Total Zinc
Non -Polar O&G/
Total Petroleum
Hy rocar ons
Total Toxic
Organics
Benchmarks
100 mg/L or 50 mg/V
6.0 — 9.0
0.010 mg/L
0.075 mg/L
0.126 mg/L
15 mg/L
1 mg/L
Parameter Code
46529
C0530
00400
01119
01051
01094
00552
78141
b o
11.
Z
G :0
1 Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
'For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
° See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies.
s Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture
electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA
Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor
manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found.in 40 CFR 469.22; and for cathode ray
tube manufacture use the definition found in 40 CFR 469.31).
Permit Date: 11/1/2018-05/31/2021. SWU-245, last revised 11/1/2018
Page 1 of 3
Facilities that incorporate a solvent management plan into the Stormwater Pollution Prevention Plan may so certify, and the requirement for TTO monitoring
may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General
Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement:
"Based upon my inquiry of the persona r persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics
(TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or
stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the
solvent management plan included in the Stormwater Pollution Prevention Plan."
Name (Print name)
Title (Print title)
Signature
Date
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format. "<XX m¢/L" where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier Z or Ter 3 responses. See General Permit text.
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month.
1 1 Ain rficrhnrno fh,'c nerind7Z
Outfall No.
Date Sample Collected) :
(mo/dd/yr)
24-hour rainfall amount,
Inches'
New Motor Oil or
Hydraulic oil Usage
Non -Polar O&G/ Total
Petroleum Hydrocarbons
Total Suspended
Solids
Benchmarks
15 mg/L
100 mg/L or So mg/L4
Parameter Code
46529
NCOIL
00552
C0530
Footnotes from Part A also apply to Part B
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier Z or Trer 3 responses. See General Permit text.
Permit Date: 11/l/2018-05/31/2021 .. - SWU-245, last revised 11/1/2018
Page 2 of 3
FOR PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENCES FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ❑ NO ❑
IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES ❑ NO ❑
REGIONAL OFFICE CONTACT NAME:
Mail an oriainal copv of this DMIT, includingall_"No Discharge" reports within 30 days of receipt of the lob results for at end of monitoring period in the
case of No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision In accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
Signature of
Permit Date:11/l/2018-05/31/2021
Date
SWU-245, last revised 11/1/2018
Page 3 of 3